You are on page 1of 10

MACAM MACAM EARTH TESTER 4200 KYORITSU EARTH TESTERS Real time measurements can be transferred, shown and

d saved on Android device (up to 100 measurements) Saved data includes measurement, GPS location and date & time Easy to check on map "When" and "Where" the measurement was made Comparator function on Android device informs when the measured value is lower/higher than the preset value Earth /Ground resistance and Leakage current measurement functions The earth resistance from 0.05 to 1200 can be measured without the auxiliary earth spikes in multiearthing systems True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments HT5600 Dual-Clamp Earth Resistance Tester Specifications clamp earth resistance tester 1.dual clamp/ ground pole two methods, 2.wide measurement range 3.strong anti-jamming ability clamp earth resistance tester, dual-clamp resistance tester Uses special dual clamps no-connecting method ,do not need subsidiary terrestrial poles, do not need insulate the grounded equipment and load, realizes on-line testing. Products features 1.Dual clamp/ ground anchor two methods: applies any ground site, single or multiple point grounding.

2. Strong anti-jamming ability 3. Wide measurement range, high resolution range: 0.01~200, resolution: 0.01, 4. Big jaw design: diameter :50mm (standard), special size according customers requirements. 5. Large-capacity data storage:200 groups 6. Easy to operate: small in volume, light in weight, portable explosion proof case, convenient to field test to carry.

Hot deal UT512 Insulation Resistance Testers 2500V

Specifications *Insulation Resistance Testers 2500V/100G ohm *Best Price with suitable price *Fast and safe delivery

New EM480A, INSULATION INSULATION RESISTANCE TESTER

Specifications *Test voltage can be changed by the rotary switch *LED used as normally working indicator under high voltage condition Insulation Resistance Tester Test voltage can be changed by the rotary switch LED used as normally working indicator under high voltage condition Audible continuity Specifications AC 700V 1V 1.5%rdg +5 dgts 200 0.1 1.0%rdg +3 dgts 2000M/250V 1K <200M 3%rdg+3dgts 200M/500V 1K >200M 5%rdg+5dgts 2000M/1000V

High voltage insulation tester AR3127 Specifications *Polarization index function *Line probe function *Connect to the computer with USB interface Product Description High voltage insulation tester AR3127

Specification: *Measuring range: Resistance: 0~1T DC/AC voltage: 30~600V *Accuracy: 5%rdg5%dgt *Rated voltage: 250V~5000V switch(in 50V each level) *Resolution 1.0V *Overload protection: AC1200V/10s *Withstand voltage: AC 8320V/5s *Polarization index function *Line probe function *Connect to the computer with USB interface *Corresponding analyse software *Designed to following safety standards: IEC 61010-19 (CAT. III safety standard) *Large LCD with backlight *Drip water and dust proof construction help them withstand extreme condition *With auto-discharge function to protect the user *Auto power shut off

HTHL-100A Contact Resistance Tester

Specifications contact resistance tester 1.LCD display, small in volume , light in weight. 2.applies to different working circumstance contact resistance tester, ground resistance tester, contact loop resistance tester.

Nowadays Power Systems widely use model QJ44 DC double arm bridge to measure contact resistance (DC resistance and Loop resistance of high-voltage circuit breaker) while the minimum current of such model is 1mA which hardly find the decrease of cross-sectional area of transformers conductive circuit conductor. The measurement of loop resistance of high voltage switchgear is affected by oil layer and oxide between static and dynamic contact port, so the resistance measurement value will be several times larger, and can not reflect the true value of contact resistance. Therefore, the Ministry of Electric Power in national standards SD301-88 "AC 500KV Electrical Equipment Transfer and Preventive Test Procedure" and new version of " Electrical Equipment Preventive Test Procedure" stipulate that the testing current of circuit breaker and isolating switch contact resistance is not less than 100A to ensure accurate test results. HTHL-100A Loop Resistance Tester measures up to the latest power system standards-DL/T845.4-2004 designed for measuring loop resistance of Switching Control Equipment using High-frequency switching power supply technology and digital circuit technology. Test current of the Tester is DC 100A which is recommended in the national standards. The tester can measure the loop resistance at this value and display the result in digital. It is high precision and good stability and can meet most power systems requirements in onsite highvoltage switches maintenance and high-voltage switches factory loop resistance measurement. (It performances accurately and stably)

GT-C14 Taber abrasion resistance tester Specifications 1 Taber abrasion resistance tester 2 Standards ISO 5470 ASTM D3884 DIN 53754 53799 53109 Taber abrasion resistance tester Taber tester, taber wear and abrasion tester, taber wear tester, taber abrasion tester.

Application To determine the wear resistance of all kinds of structures including metals, paints, plated surfaces, coated materials, textiles, leather and rubber. Uses the X pattern of abrasion produced by a rotary action of a pair of abrasive wheels. Supplied with a full range of auxiliary weights, specimen holders, abrasive wheels, wheel refacer and vacuum unit. Key Specification Abrasion Wheel Diameter Wear Round Centre Spacing Gyration Speed Dimensions Weight 52mm 53.2mm 70+/-1rpm 530 x 320 x 310mm ( L x W x H ) 18kg

New Mastech MS2307 EARTH RESISTANCE tester meter + 2 clamps 4 current leakage fit FLUKE 20V/48V Specifications *Two power supply-dry battery or rechargeable battery *Alarm function *Clock function Earth resistance clamp is a breakthrough from traditional tester. Neither the supplementary earth leads nor the break earth equipment is necessary. Ground resistance result can be get safe and fast only by clamping the ground line.It is also widely used in the field of electric power distribution, telecommunication and architectural ground. - Two pole and three pole AC resistance test and DC resistance test - Three pole and four pole earth resistance test - Four pole test the ground resistivity directly - With current-clamp selection you should not cut the earth connection - Optional test voltage 20V/48V - Automatic frequency control(AFC),can auto distinguish interference and choose the suitable test frequency, minimize the influence of interference.94Hz,105Hz,111Hz,128Hz optional. - With test data storage function, can store 100 test data, upload to the PC and analysis, output the test report - Alarm function - Clock function - Two power supply-dry battery or rechargeable battery

Insulation Resistance Tester UT511

OB Price: Get Latest Price Minimum Order Quantity: 100 Piece/Pieces Supply Ability: 1000 Piece/Pieces per Month Payment Terms: L/C,T/T

SPECIFICATIONS
Basic Functions Insulation Resistance Low Resistance Testing Voltage DC Voltage AC Voltage Special Functions Auto Ranging Short Circuit Current Data Logging Data Recall Sleep Mode Polarization index (PI) Dielectric Absorption(DAR) Timer Compare Battery Display Display Backlight Over Range and High Voltage Warning USB Max. Display 9999 Analogue Bar Graph 1000V/1500V/2500V/5000V 1000V 750V 1M~1000G 1000W 100V/250V/500V/1000V Range 500kW ~ 10G Best Accuracy 3%+5) (1%+3) 0~20% (1%+3) (1.5%+3) <2mA 18

Within 30 minutes

EL

323511 YOKOGAMA EARTH TESTERS The Model 323511 Earth Tester is a convenient test set to facilitate very easy, accurate measurements of earth resistance. Without a hand-driven generator, this instrument consists of a battery-operated silicon-transistorized DC-AC inverter, an AC potentiometer measuring dial and a galvanometer. Just push the pushbutton switch and move the dial so that the galvanometer shows balanced condition Then, resistance is directly read on the dial scale. A wide range of earth resonance of 0 to 1,000 can be measured by a single measuring dial without range changeover. Furthermore, earth voltage can also be measured on the galvanometer scale by positioning the selector switch.

You might also like