Professional Documents
Culture Documents
ANALYSIS OF MONOPOLE
SECTION 1
Analysis Criteria: Determine Wind Pressures H= 25 m V= 35 m/s GH = 1.69
Heightof Monopole Basic Design Wind speed for the structure Gust Response of Monopole as per Section 2.3.4.2 of TIA-EIA_222-F
To satisfy Section 2.3.9.3 of TIA-EIA-222-F, Calculate pressures on each section using two parts.
SECTION PROPERTIES
h= L= DB = DM = DT = 16 9 1.126 1.063 1.000 m m m m m Section base elevation Length of section Bottom Diameter of Section Midpoint Diameter of Section Top Diameter of Section
CALCULATIONS
y1 = y1 = y2 = y2 = A1 = A1 = A2 = A2 = z1 = z1 = z2 = z2 = [(2DT + DM)/3(DT + DM)]*(L/2) 2.2270965 m [(2DM + DB)/3*(DM + DB)]*(L/2) 2.2284148 m (DT + DM)*(L/2)/2 4.64175 sqm (DM + DB)*(L/2)/2 4.92525 sqm h + L/2 + y1 22.727096 m h + y2 18.228415 m Center of A1 of Section from midbase
Kz1 = Kz1 =
(z1/10)^2/7 1.2643525
Kz1 =
Kz2 = Kz2 =
1.26
(z2/10)^2/7 1.1871308
Input Value
Exposure Coefficient at A2 1 < Kz < 2.58
Kz2 =
qz1 = qz1 = qz2 = qz2 = F1= F1 = F1 = F2= F2 = F2 = F1*z1 = F2*z2 =
1.19
0.613*Kz1*v^2 949.1692 0.613*Kz2*v^2 891.34798 GH*qz1*A1 7445.8124 N 7.4458124 kN GH*qz2*A2 7419.2886 N 7.4192886 kN 169.2217 kN-m 135.24187 kN-m
Input Value
Velocity Pressure at A1
Velocity Pressure at A2
z equivalent =(F1*z1 + F2*z2)/(F1+ F2) z equivalent = 20.481769 m qzequivalent =(F1 + F2)/(1.69*(A1 + A2) qzequivalent = 919.40188 kPa Kzequivalent =(zequivalent/10)^2/7 Kzequivalent = 1.2273284 GH*qzequivalent*AT = C= C= 14865.1
Equivalent Distance of the center of the Section to its base Equivalent Velocity Pressure of Section
(Kzequivalent^0.50)*V*Dp 25.178181
>
8.7
Table 1
CF =
0.72
ANALYSIS OF MONOPOLE
SECTION 2
Analysis Criteria: Determine Wind Pressures H= 25 m V= 35 m/s GH = 1.69
Heightof Monopole Basic Design Wind speed for the structure Gust Response of Monopole as per Section 2.3.4.2 of TIA-EIA_222-F
To satisfy Section 2.3.9.3 of TIA-EIA-222-F, Calculate pressures on each section using two parts.
SECTION PROPERTIES
h= L= DB = DM = DT = 7 9 1.256 1.191 1 m m m m m Section base elevation Length of section Bottom Diameter of Section Midpoint Diameter of Section Top Diameter of Section
CALCULATIONS
y1 = y1 = y2 = y2 = A1 = A1 = A2 = A2 = z1 = z1 = z2 = z2 = [(2DT + DM)/3(DT + DM)]*(L/2) 2.22896 m [(2DM + DB)/3*(DM + DB)]*(L/2) 2.230078 m (DT + DM)*(L/2)/2 5.21325 sqm (DM + DB)*(L/2)/2 5.50575 sqm h + L/2 + y1 13.72896 m h + y2 9.230078 m Center of A1 of Section from midbase
Kz1 = Kz1 =
(z1/10)^2/7 1.094774
Kz1 =
Kz2 = Kz2 =
1.09
(z2/10)^2/7 0.97737
Input Value
Exposure Coefficient at A2 1 < Kz < 2.58
Kz2 =
qz1 = qz1 = qz2 = qz2 = F1= F1 = F1 = F2= F2 = F2 = F1*z1 = F2*z2 =
1.00
0.613*Kz1*v^2 822.0931 0.613*Kz2*v^2 750.925 GH*qz1*A1 7242.963 N 7.242963 kN GH*qz2*A2 6987.145 N 6.987145 kN 99.43835 kN-m 64.49189 kN-m
Input Value
Velocity Pressure at A1
Velocity Pressure at A2
z equivalent =(F1*z1 + F2*z2)/(F1+ F2) z equivalent = 11.51996 m qzequivalent =(F1 + F2)/(1.69*(A1 + A2) qzequivalent = 785.538 kPa Kzequivalent =(zequivalent/10)^2/7 Kzequivalent = 1.041255 GH*qzequivalent*AT = C= C= 14230.11
Equivalent Distance of the center of the Section to its base Equivalent Velocity Pressure of Section
(Kzequivalent^0.50)*V*Dp 15.77446
>
8.7
Table 1
CF =
0.72
ANALYSIS OF MONOPOLE
SECTION 3
Analysis Criteria: Determine Wind Pressures H= 25 m V= 35 m/s GH = 1.69
Heightof Monopole Basic Design Wind speed for the structure Gust Response of Monopole as per Section 2.3.4.2 of TIA-EIA_222-F
To satisfy Section 2.3.9.3 of TIA-EIA-222-F, Calculate pressures on each section using two parts.
SECTION PROPERTIES
h= L= DB = DM = DT = 0 7 1.350 1.303 1.256 m m m m m Section base elevation Length of section Bottom Diameter of Section Midpoint Diameter of Section Top Diameter of Section
CALCULATIONS
y1 = y1 = y2 = y2 = A1 = A1 = A2 = A2 = z1 = z1 = z2 = z2 = [(2DT + DM)/3(DT + DM)]*(L/2) 1.739286 m [(2DM + DB)/3*(DM + DB)]*(L/2) 1.739666 m (DT + DM)*(L/2)/2 4.47825 sqm (DM + DB)*(L/2)/2 4.64275 sqm h + L/2 + y1 5.239286 m h + y2 1.739666 m Center of A1 of Section from midbase
Kz1 = Kz1 =
(z1/10)^2/7 0.831368
Kz1 =
Kz2 = Kz2 =
1.00
(z2/10)^2/7 0.606727
Input Value
Exposure Coefficient at A2 1 < Kz < 2.58
Kz2 =
qz1 = qz1 = qz2 = qz2 = F1= F1 = F1 = F2= F2 = F2 = F1*z1 = F2*z2 =
1.00
0.613*Kz1*v^2 750.925 0.613*Kz2*v^2 750.925 GH*qz1*A1 5683.182 N 5.683182 kN GH*qz2*A2 5891.943 N 5.891943 kN 29.77582 kN-m 10.25001 kN-m
Input Value
Velocity Pressure at A1
Velocity Pressure at A2
z equivalent =(F1*z1 + F2*z2)/(F1+ F2) z equivalent = 3.457918 m qzequivalent =(F1 + F2)/(1.69*(A1 + A2) qzequivalent = 750.925 kPa Kzequivalent =(zequivalent/10)^2/7 Kzequivalent = 0.738303 GH*qzequivalent*AT = C= C= 11575.13
Equivalent Distance of the center of the Section to its base Equivalent Velocity Pressure of Section
(Kzequivalent^0.50)*V*Dp 5.654304
>
8.7
Table 1
CF =
0.72
Heightof Monopole Basic Design Wind speed for the structure Gust Response of Monopole as per Section 2.3.4.2 of TIA-EIA-222-F.
Qualifying Criteria for Force Coefficient, CF for Cantilevered Tubular pole Structures as per Section 2.3.5.2 of TIA-EIA-222-F. C= C=
(Kiz^0.50)*V*Dp
#VALUE!
>
8.7
Table 1
CF = F= OTM =
0.72
qz*GH*CF*AR F*zequivalent
TABLE II - 25.0M SELF-SUPPORTING MONOPOLE TOWER Typical tower wind load distribution as per section in normal to the tower face.
H= V= GH = 25 35 1.69 m m/s Heightof Monopole Basic Design Wind speed for the structure Gust Response of Monopole as per Section 2.3.4.2 of TIA-EIA_222-F
SECTION 1 2 3
AR(sq.m.) GH*qZ*AG F=qz*GH*CF*AR(kNs) equivalent(m) OTM(kN-m) z 9.854 14865.10 105.47 20.482 2160.13 11.041 14230.11 113.12 11.520 1303.12 9.395 11575.13 78.30 3.458 270.740
Total =
3733.99
Table I - Wind load on antenna support pipe and other mounted pole structures.
25 m 39 m/s 1.00 </=GH</=1.25 1.471 Size Dept Length, l (mm) Sec.2.3.4.1 of TIA-EIA-222-F Diameter, d (mm) 20.0 Appurtenance c/l Elev., (m) 26.00 1.313 Kz
LR
20mmx2.0m
GSM
2000
multiplied by 1.25, to compensate for the greater gust response for mounted pole structure (EIA/TIA-222-E, Sec. 2.3.4.4)
ower face.
r Section 2.3.4.2
kN-m
CF (C<4.40)
0.894
1.200