MODEL A1 A2 A3 B1 B2 B3 C1 C2 C3 C4 C5 C6 D1 E1 F1 F2 G1 H1 H2 H3 J1 J2 K1 K2 K3 K4 DESCRIPTION PAGE

MINIATURE ADJUSTABLE BAYONET STYLE THERMOCOUPLE..............................1 ADJUSTABLE BAYONET STYLE THERMOCOUPLE...................................................2 DIAMETER ADJUSTABLE BAYONET STYLE THERMOCOUPLE..........................3 FIXED BAYONET STYLE THERMOCOUPLE ...............................................................4 FIXED BAYONET STYLE THERMOCOUPLE 45 BEND............................................5 FIXED BAYONET STYLE THERMOCOUPLE 90 BEND.............................................6 TUBE & WIRE GENERAL PURPOSE THERMOCOUPLE .............................................7 GENERAL PURPOSE THERMOCOUPLE 45 BEND ....................................................8 GENERAL PURPOSE THERMOCOUPLE 90 BEND ....................................................9 METRIC SIZE TUBE & WIRE GENERAL PURPOSE THERMOCOUPLE ...................10 METRIC GENERAL PURPOSE THERMOCOUPLE 45 BEND ...................................11 METRIC GENERAL PURPOSE THERMOCOUPLE 90 BEND ...................................12 NOZZLE BOLT STYLE THERMOCOUPLE ..................................................................13 RING TERMINAL STYLE THERMOCOUPLE...............................................................14 SHIM STOCK STYLE THERMOCOUPLE. BRASS SHIM.............................................15 SHIM STOCK STYLE THERMOCOUPLE. STAINLESS STEEL SHIM ........................16 PIPE CLAMP STYLE THERMOCOUPLE. ....................................................................17 EUROPEAN ADJUSTABLE BAYONET THERMOCOUPLE ........................................18 EUROPEAN ADJUSTABLE BAYONET. EXPOSED BRASS TIP STYLE ....................19 EUROPEAN FIXED ADJUSTABLE BAYONET THERMOCOUPLE.............................20 HOT RUNNER STYLE THERMOCOUPLE...................................................................21 METRIC HOT RUNNER STYLE THERMOCOUPLE....................................................22 MELT BOLT THERMOCOUPLE. MINERAL INSULATED ...........................................23 RIGID MELT BOLT THERMOCOUPLE. MINERAL INSULATED ................................24 FIXED MELT BOLT THERMOCOUPLE. MINERAL INSULATED ...............................25 ADJUSTABLE MELT BOLT THERMOCOUPLE. MINERAL INSULATED...................26

RESISTANCE TEMPERATURE DEVICES (RTD's)


MODEL 1A 2A 3A 1B 2B 3B 1C DESCRIPTION PAGE MINIATURE ADJUSTABLE BAYONET STYLE RTD...................................................27 ADJUSTABLE BAYONET STYLE RTD........................................................................28 DIAMETER ADJUSTABLE BAYONET STYLE RTD...............................................29 FIXED BAYONET STYLE RTD ....................................................................................30 FIXED BAYONET STYLE RTD 45 BEND ...................................................................31 FIXED BAYONET STYLE RTD 90 BEND ...................................................................32 TUBE & WIRE GENERAL PURPOSE RTD .................................................................33

2C 3C 4C 5C 6C 1D 1E 1F 1G 1K 2K 3K 4K

GENERAL PURPOSE RTD 45 BEND ........................................................................34 GENERAL PURPOSE RTD 90 BEND ........................................................................35 METRIC TUBE & WIRE GENERAL PURPOSE RTD ..................................................36 METRIC GENERAL PURPOSE RTD 45 BEND .........................................................37 METRIC GENERAL PURPOSE RTD 90 BEND .........................................................38 NOZZLE BOLT STYLE RTD ........................................................................................39 RING TERMINAL STYLE RTD .....................................................................................40 SHIM STOCK STYLE RTD. STAINLESS STEEL SHIM...............................................41 PIPE CLAMP STYLE RTD ...........................................................................................42 MELT BOLT RTD. MINERAL INSULATED ..................................................................43 RIGID MELT BOLT RTD. MINERAL INSULATED .......................................................44 FIXED MELT BOLT RTD. MINERAL INSULATED.......................................................45 ADJUSTABLE MELT BOLT RTD .................................................................................46

MINERAL INSULATED TEMPERATURE SENSORS


THERMOCOUPLES
MODEL L1 M1 M2 M3 M4 M5 M6 M7 M8 N1 & N2 N3 N4 P1 P2 P3 P4 DESCRIPTION PAGE

MINERAL INSULATED SENSOR C/W PLASTIC HANDLE .........................................47 STRAIGHT BASIC ELEMENTS ....................................................................................48 GENERAL PURPOSE, STRAIGHT PROBE.................................................................49 GENERAL PURPOSE WITH A 45 BEND .......................................................... 50 GENERAL PURPOSE WITH A 90 BEND ..................................................................51 METRIC STRAIGHT ELEMENTS ................................................................................52 METRIC GENERAL PURPOSE, STRAIGHT PROBE..................................................53 METRIC GENERAL PURPOSE WITH A 45 BEND....................................................54 METRIC GENERAL PURPOSE WITH A 90 BEND....................................................55 WELDED ON HEX BUSHING MOUNTING STYLE ....................................................56 COMPRESSION FITTING MOUNTING STYLE ..........................................................57 HEX NIPPLE MOUNTING STYLE, WELDED & SPRING LOADED............................58 STANDARD STEPPED THERMOWELL ASSEMBLY .................................................59 STANDARD STRAIGHT THERMOWELL ASSEMBLY ................................................60 STANDARD TAPERED THERMOWELL ASSEMBLY. ................................................61 NIPPLE-UNION NIPPLE THERMOWELL ASSEMBLY................................................62

RESISTANCE TEMPERATURE DEVICES (RTD's)


MODEL 1L 1M 2M 3M DESCRIPTION PAGE MINERAL INSULATED SENSOR C/W PLASTIC HANDLE .........................................63 STRAIGHT BASIC ELEMENTS ....................................................................................64 GENERAL PURPOSE, STRAIGHT PROBE.................................................................65 GENERAL PURPOSE WITH A 45 BEND...................................................................66

4M 5M 6M 7M 8M 3N 4N 1P 2P 3P 4P

GENERAL PURPOSE WITH A 90 BEND...................................................................67 METRIC STRAIGHT BASIC ELEMENTS ....................................................................68 METRIC GENERAL PURPOSE, STRAIGHT PROBE..................................................69 METRIC GENERAL PURPOSE WITH A 45 BEND....................................................70 METRIC GENERAL PURPOSE WITH A 90 BEND....................................................71 COMPRESSION FITTING MOUNTING STYLE ..........................................................73 HEX NIPPLE MOUNTING STYLE, WELDED & SPRING LOADED............................74 STANDARD STEPPED THERMOWELL ASSEMBLY .................................................75 STANDARD STRAIGHT THERMOWELL ASSEMBLY ................................................76 STANDARD TAPERED THERMOWELL ASSEMBLY. ................................................77 NIPPLE-UNION NIPPLE THERMOWELL ASSEMBLY................................................78

1N & 2N WELDED ON HEX BUSHING MOUNTING STYLE .....................................................72

INDUSTRIAL THERMOCOUPLES
MODEL Q1 Q2 Q3 R1 R2 R3 S1 S2 DESCRIPTION PAGE

BASE METAL BARE THERMOCOUPLE ELEMENTS .................................................79 BASE METAL THERMOCOUPLE ELEMENTS WITH CERAMIC INSULATORS........80
BASE METAL ANGLE THERMOCOUPLE ELEMENTS WITH CERAMIC INSULATORS.........81

BASE METAL THERMOCOUPLE & METAL PROTECTION TUBE ASSEMBLY ........82


BASE METAL ANGLE THERMOCOUPLE & METAL PROTECTION TUBE ASSEMBLY ......... 83

BASE METAL THERMOCOUPLE & METAL PROTECTION TUBE ASSEMBLY .......84 BASE METAL THERMOCOUPLE & CERAMIC PROTECTION TUBE ASSEMBLY....85 BASE METAL THERMOCOUPLE, CERAMIC PROTECTION TUBE & TERMINAL . BLOCK ASSEMBLY.......................................................................................................86

NOBEL METAL THERMOCOUPLES


MODEL T1 T2 T3 T4 T5 DESCRIPTION PAGE

BARE ELEMENT THERMOCOUPLES..........................................................................87 NOBEL METAL THERMOCOUPLE ELEMENTS WITH CERAMIC INSULATORS......88 NOBEL METAL THERMOCOUPLE & METAL PROTECTION TUBE ASSEMBLY ......89 NOBEL METAL THERMOCOUPLE & CERAMIC PROTECTION TUBE ASSEMBLY .90 NOBEL METAL THERMOCOUPLE, CERAMIC PROTECTION TUBE & TERMINAL. BLOCK ASSEMBLY.......................................................................................................91

SPECIAL THERMOCOUPLE ASSEMBLIES


MODEL Z1 Z2 Z3 Z4 DESCRIPTION PAGE

FLANGED STYLE TUBE & WIRE THERMOCOUPLE PROBE ....................................92 MINERAL INSULATED THERMOCOUPLE & TERMINAL BLOCK ASSEMBLY..........93 EPOXY POTTED RTD ASSEMBLY ..............................................................................94 MAGNET MOUNT THERMOCOUPLE ..........................................................................95

ACCESSORIES
MODEL DESCRIPTION PAGE

P-SERIES THERMOWELLS ..........................................................................................................96 X1 X2 THERMOCOUPLE EXTENSION CABLES ..................................................................97 RTD EXTENSION CABLES.........................................................................................98 STANDARD CONNECTORS .......................................................................................99 PANEL JACKS .......................................................................................................... 100 MINI MALE CONNECTORS ..................................................................................... 101 FEMALE CONNECTORS ......................................................................................... 101 STANDARD PANEL PLATES ................................................................................... 102 BAYONET ADAPTORS ............................................................................................ 103 METRIC ADAPTORS................................................................................................ 104 2-WIRE TRANSMITTERS......................................................................................... 105 NYLON BARRIER TERMINAL STRIPS.................................................................... 106 COMPRESSION FITTINGS ...................................................................................... 107

THERMOCOUPLE WIRE:
PVC INSULATED CABLE, RATED FOR 221F (105C) MAX.......................... 108-109 SHIELDED PVC INSULATED CABLE, RATED FOR 221F (105C) ................ 110-111 PFA INSULATED CABLE, RATED FOR 500F (260C) MAX........................... 112-113 FIBERGLASS INSULATED CABLE, RATED FOR 950F (105C) MAX ........... 114-115

DATA:
COLOR CODES ........................................................................................................ 116 TEMPERATURE AND METRIC CONVERSION DATA............................................ 117

Plastic Industry Thermocouples


Miniature Adjustable Bayonet Style Thermocouple
1/8" O.D. Maximum operating temperature 900 F or 500 C.

1/4"

7"
NORDIC SENSORS

3"

Bayonet cap runs along spring & armor cable length. Steps To Follow: Model No.
1. 2. 3. 4. 5. 6.

A1
Calibration

1.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

4.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid 0.210" O.D. Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

Junction
G U Grounded Ungrounded

5.

Termination Type
1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

3.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

6.

Accessories
A None B Bx Connector C Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Adjustable Bayonet Style Thermocouple
3/16" O.D. Maximum operating temperature 900 F or 500 C.

1/4"

10"
NORDIC SENSORS

3"

Bayonet cap runs along spring & armor cable length. Steps To Follow: Model No.

1.

2.

3.

4.

5.

6.

7.

A2
Calibration

1.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum D Dual J: (+) Iron Vs. (-) Constantan Y Dual K: (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

4.

Wire Description
S X F T 20 Gage Stranded Stainless Steel Braid Flexible Armor Cable 20 Gage Stranded Fiberglass Cable 20 Gage Stranded Teflon Cable

5. 2.
Junction
G U Grounded Ungrounded

Termination Type
1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

6. 3.
"B" Dimension 0 4 8 "B"= ________"
Leads Wire Length In Inches

Accessories
A None B Bx Connector C Cable Clamp

7.

Probe Tip Descripsion


1 Flat Tip 2 Radius Tip 3 Drill Point Tip

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


1/4" Adjustable Bayonet Style Thermocouple
1/4" O.D. Maximum operating temperature 900 F or 500 C.

1/2"

10"
NORDIC SENSORS

3"

Bayonet cap runs along spring & armor cable length. Steps To Follow: Model No.

1.

2.

3.

4.

5.

6.

7.

A3
Calibration

1.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum D Dual J: (+) Iron Vs. (-) Constantan Y Dual K: (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

4.

Wire Description
S X F T 20 Gage Stranded Stainless Steel Braid Flexible Armor Cable 20 Gage Stranded Fiberglass Cable 20 Gage Stranded Teflon Cable

5. 2.
Junction
G U Grounded Ungrounded

Termination Type
1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

6. 3.
"B" Dimension 0 4 8 "B"= ________"
Leads Wire Length In Inches

Accessories
A None B Bx Connector C Cable Clamp

7.

Probe Tip Descripsion


1 Flat Tip 2 Radius Tip 3 Drill Point Tip

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Fixed Bayonet Style Thermocouple
Model Code: B1
U 1/2"
NORDIC SENSORS

Maximum operating temperature 900 F or 500 C.

3/16" O.D. 1 5/8"


A B C D E F

B
G H I J K

B1
A Diameter
A B C 1/8" 3/16" 1/4"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable: 4 Armor Flexible Cable

I Protection

Outer Jacket

0.280" Outside Diameter 0.210" Outside Diameter

"U" Dimension

F
Single Duplex

Junction Styles

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Element Grounded Ungrounded Description Common Common Isolated


G D C U I

Metal Braid Protection not available on P.V.C insulation cable.

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

J G
1 2 3 4

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

A B C D E F

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Fixed Bayonet Style Thermocouple. 45 Bend.
Model Code: B2
1 1/2"
NORDIC SENSORS

Maximum operating temperature 900 F or 500 C.

1/ 2"

U
5/ 8"

45 Deg.

B
1

3/16" O.D.

B2
A Diameter
A B C 1/8" 3/16" 1/4"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable:


0.280" Outside Diameter

I Protection

Outer Jacket

4 Armor Flexible Cable

"U" Dimension

F
Single Duplex

Junction Styles
Grounded
Common

0.210" Outside Diameter

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Element Description

Ungrounded
Common Isolated

Metal Braid Protection not available on P.V.C insulation cable.

G D C

U I

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

J G
1 2 3 4

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

A B C D E F

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Fixed Bayonet Style Thermocouple. 90 Bend.
7/8"
NORDIC SENSORS

Model Code: B3

1 1/2"

R = 5/8"

1 5/8"

3/16" or 1/8" O.D.

Maximum operating temperature 900 F or 500 C.


F G H I J K

B3
A Diameter
A B C 1/8" 3/16" 1/4"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable: 4 Armor Flexible Cable

I Protection

Outer Jacket

0.280" Outside Diameter 0.210" Outside Diameter

"U" Dimension

F
Single Duplex

Junction Styles
Grounded
Common

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Element Description

Ungrounded
Common Isolated

Metal Braid Protection not available on P.V.C insulation cable.

G D C

U I

C Fractional
A B C D E F G H 0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

"U" Length

G
1 2 3 4

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

J
A B C D E F

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Tube & Wire General Purpose Thermocouple
Model Code: C1
Outside Dimension Compression Fitting ( Optional). Item purchased separately

3 1/2" Maximum operating temperature: 900F or 500C

C1
A Diameter
A B C D 1/8" 3/16" 1/4" 5/16"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable:


0.280" Outside Diameter

I Protection

Outer Jacket

4 Armor Flexible Cable

"U" B Dimension
Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

F
Single Duplex

Junction Styles
Grounded
Common

0.210" Outside Diameter

Element Description

Ungrounded
Common Isolated

Metal Braid Protection not available on P.V.C insulation cable.

G D C

U I

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

J G
1 2 3 4

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

A B C D E F

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouple


General Purpose Thermocouple-45 Bend
Model Code: C2
U
Maximum operating temperature: 900F or 500C

1 1/2"
NORDIC SENSORS

45 Bend

Compression Fitting ( Optional). Item purchased separately C D E F H I G

C2
A Diameter
A B C D 1/8" 3/16" 1/4" 5/16"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable: 4 Armor Flexible Cable

I Protection

Outer Jacket

0.280" Outside Diameter 0.210" Outside Diameter

"U" Dimension

F
Single Duplex

Junction Styles

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Element Grounded Ungrounded Description Common Common Isolated


G D C U I

Metal Braid Protection not available on P.V.C insulation cable.

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

J G
1 2 3 4

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

A B C D E F

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Plastic Industry Thermocouple


General Purpose Thermocouple-90 Bend
7/8" R = 5/8"
NORDIC SENSORS

Model Code: C3

1 1/2"

Maximum operating temperature: 900F or 500C

Compression Fitting ( Optional). Item purchased separately

C3
A Diameter
A B C D 1/8" 3/16" 1/4" 5/16"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable: 4 Armor Flexible Cable

I Protection

Outer Jacket

0.280" Outside Diameter 0.210" Outside Diameter

"U" B Dimension
Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

F
Single Duplex

Junction Styles
Ungrounded
Common Isolated

Element Grounded Description Common


G D

Metal Braid Protection not available on P.V.C insulation cable.

U C I

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8" 1 2 3 4

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

J
A B C D E F

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

1 None 2 Bx Connector 3 Cable Clamp

K Options

Termination

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Metric Size Tube & Wire General Purpose Thermocouple
Model Code: C4
Outside Dimension Compression Fitting ( Optional). Item purchased separately

90 mm Maximum operating temperature: 500C

C4
A Diameter
A B C D E 2mm 3mm 4mm 5mm 6mm

Outside

"B" Dimension

Specify " B " Length In Meters 0 3 Example "B" is 3 M = 03

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable:


7.11mm Outside Diameter

H Protection

Outer Jacket

4 Armor Flexible Cable


5.33mm Outside Diameter

"U" B Dimension
Specify " U " Length In mm 1 5 0 Example "U" , is 150mm = 150

Metal Braid Protection not available on P.V.C insulation cable.

F
1 2 3 4

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

I
A B C D E F

Termination
90mm Split leads & bare ends
90mm Split leads & No.10 spade lugs.

C Calibration
J K T White Yellow Blue Red Red Red

Standard Male Plug ( 218 C ) Standard Female Jack ( 218 C ) Mini Male Plug ( 218 C ) Mini Female Jack ( 218 C )

D
Single Duplex

Junction Styles
Grounded
Common

G
A B C D E

Cable Insulation Description

Element Description

Ungrounded
Common Isolated

G D C

U I

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

J Options

Termination

1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouple


Metric General Purpose Thermocouple-45 Bend
Model Code: C5
U
Maximum operating temperature: 500C

38mm
NORDIC SENSORS

45 Bend

Compression Fitting ( Optional). Item purchased separately A B C D E F G H I J

C5
A Diameter
A B C D E 2mm 3mm 4mm 5mm 6mm

Outside

"B" Dimension

Specify " B " Length 0 3 In Meters Example "B" is 3 M = 03

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable: 4 Armor Flexible Cable

H Protection

Outer Jacket

7.11mm Outside Diameter 5.33mm Outside Diameter

"U" B Dimension
Specify " U " Length In mm 1 5 0 Example "U" , is 150mm = 150

Metal Braid Protection not available on P.V.C insulation cable.

F
1 2 3 4

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

I
A B C D E F

Termination
90mm Split leads & bare ends
90mm Split leads & No.10 spade lugs.

C
J K T

Calibration
White Yellow Blue Red Red Red

Standard Male Plug ( 218 C ) Standard Female Jack ( 218 C ) Mini Male Plug ( 218 C ) Mini Female Jack ( 218 C )

D
Single Duplex

Junction Styles
Grounded
Common

G
A B C D E

Cable Insulation Description

Element Description

Ungrounded
Common Isolated

G D C

U I

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

J Options

Termination

1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouple


Metric General Purpose Thermocouple-90 Bend
7/8" R = 5/8"
NORDIC SENSORS

Model Code: C6

1 1/2"

Maximum operating temperature: 900F or 500C

Compression Fitting ( Optional). Item purchased separately

C6
A Diameter
A B C D E 2mm 3mm 4mm 5mm 6mm

Outside

"B" Dimension

Specify " B " Length 0 3 In Meters Example "B" is 3 M = 03

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable:


7.11mm Outside Diameter

H Protection

Outer Jacket

4 Armor Flexible Cable


5.33mm Outside Diameter

"U" Dimension

Metal Braid Protection not available on P.V.C insulation cable.

Specify " U " Length In mm 1 5 0 Example "U" , is 150mm = 150

F
1 2 3 4

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

I
A B C D E F

Termination
90mm Split leads & bare ends
90mm Split leads & No.10 spade lugs.

C Calibration
J K T White Yellow Blue Red Red Red

Standard Male Plug ( 218 C ) Standard Female Jack ( 218 C ) Mini Male Plug ( 218 C ) Mini Female Jack ( 218 C )

D
Single Duplex

Junction Styles
Ungrounded
Common Isolated

G
A B C D E

Cable Insulation Description

Element Grounded Description Common


G D

U C I

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

J Options

Termination

1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Nozzle Bolt Style Thermocouple
Model Code: D1
3/8" 3/8" O.D. Strain Relief Spring

Maximum operating temperature: 900F or 500C

1 1/2" 1/2"

3 1/2"

Steps: Model:

1.

2.

3.

4.

5.

6.

7.

D1
1 2 3 4

1.

Nozzle Bolt Thread Size


1/4" x 28 UNF M6 x 1mm M8 x 1mm M8 x 1.25mm

5.

"B" Dimension

0 4 8 "B"= ________"
Leads Wire Length In Inches

2.

Wire Description
S X F T 20 Gage Stranded Stainless Steel Braid Flexible Armor Cable 20 Gage Stranded Fiberglass Cable 20 Gage Stranded Teflon Cable

6.

Termination Type
A 3" Split Leads & 1/2" Bare Ends. B 3" Slip Leads & No.10 Spade Lugs C Standard Male Plug D Standard Female Jack E Mini Male Plug F Mini Female Jack

3.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

7. 4.
Junction
G U Grounded Ungrounded

Accessories
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Ring Terminal Style Thermocouple
Model Code: E1
Maximum operating temperature: 900F or 500C

3/4"

3"

Unground Style Configeration


1/8" O.D. 1"

Steps: Model:

1.

2.

3.

4.

5.

6.

7.

E1
1 No. 8 Ring Terminal 2 No. 10 Ring Terminal 3 1/4" I.D. Hole Ring Terminal 4 1/2" I.D. Hole Ring Terminal

1.

Ring Terminal Hole Size

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S X F T 20 Gage Stranded Stainless Steel Braid Flexible Armor Cable 20 Gage Stranded Fiberglass Cable 20 Gage Stranded Teflon Cable

6.

Termination Type
A 3" Split Leads & 1/2" Bare Ends. B 3" Slip Leads & No.10 Spade Lugs C Standard Male Plug D Standard Female Jack E Mini Male Plug F Mini Female Jack

3.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum T (+) Copper Vs. (-) Copper-Nickel

Calibration

7.

Accessories
1 None 2 Bx Connector 3 Cable Clamp

4.

Junction
G U Grounded Ungrounded

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Shim Stock Style Thermocouple. Brass Shim
" 10 .020" 0.0 0

Model Code: F1
Maximum operating temperature: 900F or 500C
Flexible 1/8" O.D brass stem.

W
Grounded Junction Only

0.315"

B
1"
1. 2. 3. 4. 5. 6.

3"

L Steps: Model:

F1
Shim Size: Width x Length
1/2" x 1/2" 3/4" x 3/4" 3/4" x 7/8" 1" x 1"

1.

1 2 3 4

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S 20 Gage, Stranded, Stainless Steel Braid F 20 Gage, Stranded, Fiberglass Cable

5.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & No. 10 Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

3.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

6.

Accessories
1 None 2 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Shim Stock Style Thermocouple. Stainless Steel Shim
" 24 0.0

Model Code: F2
Maximum operating temperature: 900F or 500C
3/16" O.D Stainless Steel Stem.

1"

3"

Steps: Model:

1.

2.

3.

4.

5.

6.

7.

F2
1 2 3 4

1.

Shim Size: Width x Length


1/2" x 1/2" 3/4" x 3/4" 3/4" x 7/8" 1" x 1"

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

5. 2.
Wire Description
S 20 Gage, Stranded, Stainless Steel Braid F 20 Gage, Stranded, Fiberglass Cable X Flexible Armor Cable

Junction
G U Grounded Ungrounded

6.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & No.10 Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

3.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

7.

Accessories
A None B Bx Connector C Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Pipe Clamp Style Thermocouple
Maximum operating temperature: 900F or 500C
3/8"

Model Code: G1
A
3/16"

A
1/2" 1/8"

1" Steps To Follow: Model No.

B
3. 4. 5. 6.

3"

1.

2.

G1
Pipe Clamp Description

1.
1 2 3 4 5

A= Diameter Range Minimum Maximum 2" 1 1/16" 1 13/16" 2 3/4" 2 9/16" 3 1/2" 3" 5" 5" 7"

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S 20 Gage Stranded Stainless Steel Braid X Flexible Armor Cable F 20 Gage Stranded Fiberglass Cable

5.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

3.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

6.

Accessories
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


European Adjustable Bayonet
Model Code: H1
Metric Double Pin Bayonet Cap 8mm O.D Metric Double Slotted Bayonet Cap Spring Outside Diameter: 8mm O.D. European Stainless Steel Braid ( 22 AWG Stranded ) Maximum operating temperature: 900F or 500C

190mm
14mm

90mm

B Dimension

Steps To Follow:

1.

2.

3.

4.

5.

6.

Model: 1.

H1
Radius Tip Style Flat Tip Style

Probe Tip Description


R F

4.

"B" Dimension 3M 0 48 "B"= _____" OR "B"= _____


Length In Inches

Length In Meters

2.

Bayonet Cap Option


1 2 3 4 M12 Bayonet Cap M14 Bayonet Cap M16 Bayonet Cap Double Pin Bayonet Cap

5.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

3.

Termination Type
A 3 1/2" Split Leads & 1/2" Bare Ends. B 3 1/2" Split Leads & Pin Connectors C Standard Male Plug D Standard Female Jack E Mini Male Plug F Mini Female Jack

6.
Single Dual

Junction Styles
Grounded G D Ungrounded U Y

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


European Adjustable Bayonet , Exposed Brass Tip Style
Model Code: H2
Exposed Junction Metric Double Pin Bayonet Cap 8mm O.D Metric Double Slotted Bayonet Cap European Stainless Steel Braid ( 22 AWG Stranded ) Maximum operating temperature: 900F or 500C

190mm
Spring Outside Diameter: 8mm O.D. 14mm

90mm

B Dimension

Steps To Follow:

1.

2.

3.

4.

Model: 1.

H2
3.
"B" Dimension 0 48 3M "B"= _____" OR "B"= _____
Length In Inches

Bayonet Cap Option


1 2 3 4 M12 Bayonet Cap M14 Bayonet Cap M16 Bayonet Cap Double Pin Bayonet Cap

Length In Meters

2.

Termination Type
A B C D E F 3 1/2" Split Leads & 1/2" Bare Ends. 3 1/2" Split Leads & Pin Connectors Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

4.

J K

(+) Iron Vs. (-) Constantan (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


European Fixed Adjustable Bayonet
Model Code: H3
Metric Double Pin Bayonet Cap 3mm or 4mm O.D
Flat Tip

Maximum operating temperature: 900F or 500C

Metric Double Slotted Bayonet Cap Spring Outside Diameter: 8mm O.D.

European Stainless Steel Braid ( 22 AWG Stranded )

190mm

90mm

B Dimension
Steps To Follow:

1.

2.

3.

4.

5.

6.

7.

Model: 1.

H3
Probe Tip Diameter
3mm Outside Diameter 4mm Outside Diameter

A B

4.

"B" Dimension 0 48 3M "B"= _____" OR "B"= _____


Length In Inches

Length In Meters

2.

"U" Dimension 25 "U"= _____mm


Length In MM

5.

Termination Type
A 3 1/2" Split Leads & 1/2" Bare Ends. B 3 1/2" Split Leads & Pin Connectors C Standard Male Plug D Standard Female Jack E Mini Male Plug F Mini Female Jack

3.

Bayonet Cap Option


A B C D M12 Bayonet Cap M14 Bayonet Cap M16 Bayonet Cap Double Pin Bayonet Cap

6.

J (+) Iron Vs. (-) Constantan K (+) Ni.-Chromium Vs. (-) Ni.-Aluminum

Calibration

7.
Single Dual

Junction Styles
Grounded G D Ungrounded U Y

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Hot Runner Style Thermocouple
Model Code: J1
0.236" O.D. Maximum operating temperature: 900F or 500C

1"

3"

Compression fittings are sold seperatly. See accessory section. A Model: B C D E F G H I

J1
Outside Diameter

D
A B C D E F G H I N

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

"B" Dimension

1 0.020" = 0.5mm 2 0.032" 3 0.040" = 1mm 4 0.059" = 1.5mm 5 0.063"

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F

Cable Insulation Description


24 Gage, Stranded, Kapton 24 Gage, Solid, Kapton 24 Gage, Stranded, Teflon 24 Gage, Solid, Teflon 24 Gage, Stranded, Fiberglass 24 Gage, Solid, Fiberglass

Sheath Material

A 304 Stainless B 316 Stainless C Inconel 600

E
1 2 3 4 5

Calibration

Standard Special Limits of Limits of Error Error

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

I
1 2 3 4 5 6 7 8

Termination
3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

F
Single

Junction Styles
Grounded
Common

Element Description
Duplex

Ungrounded
Common Isolated

G D F

U H

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Metric Hot Runner Style Thermocouple
Model Code: J2
Outside Diameter 6mm O.D. Epoxy Potting Maximum operating temperature: 500F or 260C

25mm

50mm

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

J2
A
1 2 3

Outside Diameter
0.5mm 1mm 1.5mm

D
1 2 3 4 5

Calibration

"B" Dimension

Standard Special Limits of Limits of Error Error

Specify " B " Length In Meters 0 2 Example "B" is 2M = 02

Sheath Material

J K T E N

6 7 8 9 10

J K T E N

G
A B C D E F

Cable Insulation Description


24 Gage, Stranded, Kapton 24 Gage, Solid, Kapton 24 Gage, Stranded, Teflon 24 Gage, Solid, Teflon 24 Gage, Stranded, Fiberglass 24 Gage, Solid, Fiberglass

A 304 Stainless B 316 Stainless C Inconel 600

"U" Dimension

E
Single

Junction Styles
Grounded
Common

H
1 2 3 4 5 6 7 8

Termination

Specify " U " Length 1 5 0 In mm Example "U" is 150mm = 150

Element Description
Duplex

Ungrounded
Common Isolated

G D F

U H

50mm Split Leads,15mm bare ends. 50mm Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Melt Bolt Thermocouple. Mineral Insulated
Model Code: K1
1/2" -20 UNF Operating Temperature: -200 C to +500 C

Flexible Armor Cable


NORDIC SENSORS

Transition Fitting U

Steps: Model

K1
Melt Bolt Length " L "
3" 4" 6"

A
3 4 6

D
1 2 3 4 5

Calibration

"B" Dimension

Standard Special Limits of Limits of Error Error

Specify " B " Length In Inches 0 4 8 Example "B" is 048 =48"

B
F A B C

"U" Tip Diameter


Flush Tip 0.125" 0.188" 0.250"

J K T E N

6 7 8 9 10

J K T E N

G
A B C D E F

Termination
3" Split leads, 1/2" bare ends.
3" Split leads & No. 10 spade lugs.

E
Single Duplex

Junction Styles
Ungrounded
Common Isolated

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

Element Grounded Description Common


G D

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

U F H

H Options

Termination

1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Rigid Melt Bolt Thermocouple. Mineral Insulated
Model Code: K2
Tip Diameter 1/2" x 20 UNF
304 Stainless Steel Bar 2 1/4" U
NORDIC SENSORS

Operating Temperature: -200 C to +500 C

Steps: Model

K2
Melt Bolt Length " L "
3" 4" 6"

A
3 4 6

D
1 2 3 4 5

Calibration

F
1 2 3 4

Termination

Standard Special Limits of Limits of Error Error

B
F A B C

"U" Tip Diameter


Flush Tip 0.125" 0.188" 0.250"

J K T E N

6 7 8 9 10

J K T E N

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

E
Single Duplex

Junction Styles
Ungrounded
Common Isolated

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

Element Grounded Description Common


G D

U F H

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Fixed Melt Bolt Thermocouple. Mineral Insulated
Model Code: K3
1/2" -20 UNF Operating Temperature: -200 C to +500 C

Sheath diameter is the same as tip diameter


U

Steps: Model

NORDIC SENSORS

Mineral Insulated 316 SS Metal Sheath

K3
Melt Bolt Length " L "
3" 4" 6"

A
3 4 6

D
1 2 3 4 5

Calibration

"B" Dimension

Standard Special Limits of Limits of Error Error

Specify " B " Length 0 4 In Inches Example "B" is 04 = 4"

B
F A B C

"U" Tip Diameter


Flush Tip 0.125" 0.188" 0.250"

J K T E N

6 7 8 9 10

J K T E N

E
Single Duplex

Junction Styles
Ungrounded
Common Isolated

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

Element Grounded Description Common


G D

G
A B C D

Termination

U F M

Standard Male Plug. Standard Female Jack. Mini Male Plug. Mini Female Jack.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry Thermocouples


Adjustable Melt Bolt Thermocouple. Mineral Insulated
Model Code: K4
1/2" -20 UNF Operating Temperature: -200 C to +500 C Mineral Insulated 316 SS Metal Sheath
NORDIC SENSORS

Compression Fitting
U

Steps: Model

K4
Melt Bolt Length " L "
3" 4" 6"

A
3 4 6

D
1 2 3 4 5

Calibration

"B" Dimension

Standard Special Limits of Limits of Error Error

Specify " B " Length 0 4 In Inches Example "B" is 04" = 4"

B
F A B C

"U" Tip Diameter


Flush Tip 0.125" 0.188" 0.250"

J K T E N

6 7 8 9 10

J K T E N

E
Single Duplex

Junction Styles
Grounded
Common

Element Description

Ungrounded
Common Isolated

G
A B C D

Termination

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

G D F

U H

Standard Male Plug. Standard Female Jack. Mini Male Plug. Mini Female Jack.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Miniature Adjustable Bayonet Style RTD
Armor cable outside diameter: 0.210"
1/2"

Operating Temperature: -200 C to +250 C

B
Bayonet cap runs along armor cable length.
NORDIC SENSORS

1/8" O.D.

Steps To Follow:

Model:

1A

1.

2.

3.

4.

5.

1.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

2.

Accessories
N X C None Bx Connector Cable Clamp

5.

RTD Wire Connection


2 3 4 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

3.

"B" Dimension

3 Wire Configuration
RED RED

WHITE WHITE

0 4 8 "B"= ________"
Leads Wire Length In Inches

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Adjustable Bayonet Style RTD
3/16" O.D. Low temperature application

1/2"

10" B
NORDIC SENSORS

3 1/2"

Standard bayonet cap runs along spring & armor cable length.
1. 2. 3. 4. 5. 6.

Operating Temperature: -200 C to +250 C

2A
1.
Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

5. 2.
Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) Mini Female Jack

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

6.

RTD Wire Connection


2 3 4 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

3.

Accessories
N X C None Bx Connector Cable Clamp

2 Wire Configuration

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


1/4" Diameter Adjustable Bayonet Style RTD
1/4" O.D.
Operating Temperature: -200 C to +250 C

1/2"

10"
NORDIC SENSORS

3"

Bayonet cap runs along spring & armor cable length. Steps To Follow:

Model:

3A

1.

2.

3.

4.

5.

6.

1.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

4.

"B" Dimension

0 4 8 "B"= ________"
Leads Wire Length In Inches

5. 2.
Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

RTD Element Type


Ohms 1 x Pt100 2 x Pt100 1 x Pt1000 2 x Pt1000 Class A 1 3 5 7 Class B 2 4 6 8

Temperature Coefficient: 0.00385 Platinum element IEC 751

6.

RTD Wire Connection


2 3 4 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
RED RED RED RED

3.

Accessories
N X C None Bx Connector Cable Clamp

2 Wire Configuration

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Fixed Bayonet Style RTD.
A
3/16" O.D. 1/2" Low temperature application

Model Code: 1B
NORDIC SENSORS

1 5/8" Standard 12mm I.D. bayonet cap

B
Operating Temperature: -200 C to +250 C
4. 5. 6. 7.

Steps To Follow: Model:

1.

2.

3.

1B
"A" Dimension 0 2 "A"= ________"
Insertion Length In Inches

1.

4.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

6.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

3.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

7.
WHITE WHITE

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Fixed Bayonet Style RTD. 45 Bend
1 1/2"
NORDIC SENSORS

Low temperature application

Model Code: 2B

A
1 5/ 8"

1/ 2"

B
Standard 12mm I.D. bayonet cap
1. 2. 3. 4.

3/16" O.D. Steps To Follow: Model:

Operating Temperature: -200 C to +250 C


5. 6. 7.

2B
"A" Dimension 0 2 "A"= ________"
Insertion Length In Inches

1.

4.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

6.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

3.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

7.
WHITE WHITE

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Fixed Bayonet Style RTD, 90 Bend
1 1/2"
NORDIC SENSORS

Low temperature application

7/8"

R = 5/8"

A
Steps To Follow: Model:

1 5/8"

Model Code: 3B
Operating Temperature: -200 C to +250 C
3. 4. 5. 6. 7.

3/16" O.D.
1. 2.

3B
"A" Dimension 0 2 "A"= ________"
Insertion Length In Inches

1.

4.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

6.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

3.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

7.
WHITE WHITE

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Tube & Wire General Purpose RTD.
A
NORDIC SENSORS

B
Thin Film Element Model:

Model Code: 1C
Low temperature RTD. -200C to +250C
3. 4. 5. 6. 7. 8.

1C
1.
A B C

1.

2.

Outside Diameter
1/8" 3/16" 1/4"

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 0 2 "A"= ________"


Insertion Length In Inches

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

6.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

7.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


General Purpose RTD. 45 Bend
1 1/2"
NORDIC SENSORS

45 Bend

B
Thin Film Element

Model Code: 2C
Operating Temperature: -200 C to +250 C
4. 5. 6. 7. 8.

Model:

2C
1.
A B C

1.

2.

3.

Outside Diameter
1/8" 3/16" 1/4"

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 0 2 "A"= ________"


Insertion Length In Inches

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 1 x Pt1000 5 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

6.

"B" Dimension

0 4 8 "B"= ________"
Leads Wire Length In Inches

7.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


General Purpose RTD. 90 Bend
1 1/2"
NORDIC SENSORS

7/8" R = 5/8"

B
Thin Film Element

A
1. 2. 3.

Model Code: 3C
Operating Temperature: -200 C to +250 C
5. 6. 7. 8.

Model:

3C
1.
A B C

4.

Outside Diameter
1/8" 3/16" 1/4"

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 0 2 "A"= ________"


Insertion Length In Inches

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

6.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

7.

Termination Type
A B C D E F 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

WHITE

Plastic Industry RTD's


Metric Size Tube & Wire General Purpose RTD
A
NORDIC SENSORS

B
Thin Film Element Model:

Model Code: 4C
Low temperature RTD. -200C to +250C
3. 4. 5. 6. 7. 8.

4C
1.
A B C D

1.

2.

Outside Diameter
3mm 4mm 5mm 6mm

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 150 "A"= ________"


Insertion Length In mm

6.

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension 0 1 "B"= ________"


Leads Wire Length In Meters

7.

Termination Type
A B C D E F 90mm Split Leads & Bare Ends. 90mm Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

WHITE

Plastic Industry RTD's


Metric Size General Purpose RTD. 45 Bend
1 1/2"
NORDIC SENSORS

45 Bend

B
Thin Film Element

Model Code: 5C
Operating Temperature: -200 C to +250 C
4. 5. 6. 7. 8.

Model:

5C
1.
A B C D

1.

2.

3.

Outside Diameter
3mm 4mm 5mm 6mm

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 150 "A"= ________"


Insertion Length In mm

6.

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension 0 1 "B"= ________"


Leads Wire Length In Meters

7.

Termination Type
A B C D E F 90mm Split Leads & Bare Ends. 90mm Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


General Purpose RTD. 90 Bend
1 1/2"
NORDIC SENSORS

7/8" R = 5/8"

B
Thin Film Element

Model Code: 6C
Operating Temperature: -200 C to +250 C
5. 6. 7. 8.

6C
1.
A B C D

1.

2.

3.

4.

Outside Diameter
3mm 4mm 5mm 6mm

5.

Wire Description
S X F T 24 Gage Stranded Stainless Steel Braid Flexible Armor Cable 24 Gage Stranded Fiberglass Cable 24 Gage Stranded Teflon Cable

2.

"A" Dimension 150 "A"= ________"


Insertion Length In mm

6.

3.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension 0 1 "B"= ________"


Leads Wire Length In Meters

7.

Termination Type
A B C D E F 90mm Split Leads & Bare Ends. 90mm Slip Leads & Spade Lugs Standard Male Plug (2 & 3 Wire config. only) Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

4.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

8.

Accessories
1 2 3 None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

WHITE

Plastic Industry RTD's


Nozzle Bolt Style RTD
Model Code: 1D
3/8" Operating Temperature: -200 C to +250 C

1/2"

1 1/2"

3 1/2"

Model:

1D
1 2 3 4 5

1.

2.

3.

4.

5.

6.

7.

1.

Nozzle Bolt Thread Size


1/4" x 28 UNF M6 x 1mm M6 x 1.25mm M8 x 1mm M8 x 1.25mm

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S T X F C 26 Gage, Stranded, Stainless Steel Braid 26 Gage, Stranded, Teflon 0.210 O.D., Flexible Armor, Teflon Wire 26 Gage, Stranded, Fiberglass Cable 0.210 O.D., Flexible Armor, Fiberglass Wire

6.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

3.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) Mini Female Jack

7.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED

2 Wire Configuration

4.

Accessories
A B C None Bx Connector Cable Clamp

RED

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Ring Terminal Style RTD.
Model Code: 1E
1/8" O.D Operating Temperature: -200 C to +250 C

Epoxy Potting 3/4" 1 1/2"

B
2. 3. 4. 5. 6. 7.

3 1/2"

Model:

1E
1 2 3 4

1.

1.

Ring Terminal Hole Size


No. 8 Screw No. 10 Screw 1/4" Hole 1/2" Hole

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S T X F C 26 Gage, Stranded, Stainless Steel Braid 26 Gage, Stranded, Teflon 0.210 O.D., Flexible Armor, Teflon Wire 26 Gage, Stranded, Fiberglass Cable 0.210 O.D., Flexible Armor, Fiberglass Wire

6.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 1 x Pt1000 5 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

3.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) Mini Female Jack

7.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED

2 Wire Configuration

4.

Accessories
A B C None Bx Connector Cable Clamp

RED

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Shim Stock Style RTD. Stainless Steel Shim
" 24 0.0

Model Code: 1F
Operating Temperature: -200 C to +250 C 3/16" O.D Stainless Steel Stem.

W
Epoxy Potting

1 1/2" 2. 3. 4.

B
5. 6. 7.

3 1/2"

Model:

1F
1 2 3 4

1.

1.

Shim Size: Width x Length


1/2" x 1/2" 3/4" x 3/4" 3/4" x 7/8" 1" x 1"

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

2.

Wire Description
S T X F C 26 Gage, Stranded, Stainless Steel Braid 26 Gage, Stranded, Teflon 0.210 O.D., Flexible Armor, Teflon Wire 26 Gage, Stranded, Fiberglass Cable 0.210 O.D., Flexible Armor, Fiberglass Wire

6.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

3.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) Mini Female Jack

7.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED

2 Wire Configuration

4.

Accessories
A B C None Bx Connector Cable Clamp

RED

3 Wire Configuration
RED RED

WHITE WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

WHITE

Plastic Industry RTDs


Pipe Clamp Style RTD
Operating Temperature: -200 C to +250 C
3/8"

Model Code: 1G
A
3/16"

A
1/2" 1/8"

1"

3"

Model:

1G

1.

2.

3.

4.

5.

6.

7.

1.
1 2 3 4 5

Pipe Clamp Description


A = Diameter Range Maximum Minimum 1 1/16" 2" 1 13/16" 2 3/4" 2 9/16" 3 1/2" 5" 3" 5" 7"

5.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

6.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

2.

Wire Description
S T X F C 26 Gage, Stranded, Stainless Steel Braid 26 Gage, Stranded, Teflon 0.210 O.D., Flexible Armor, Teflon Wire 26 Gage, Stranded, Fiberglass Cable 0.210 O.D., Flexible Armor, Fiberglass Wire

3.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) Mini Female Jack

7.

RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

2 Wire Configuration

4.

Accessories
A B C None Bx Connector Cable Clamp

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Melt Bolt RTD. Mineral Insulated
Model Code: 1K
1/2" -20 UNF Operating Temperature: -200 C to +500 C Flexible Armor Cable
NORDIC SENSORS

Transition Fitting
U

L
A B C E

Mineral insulated 316SS sensor tip. Model D


F

1K
A
1 2 3

Melt Bolt Length " L "


3" 4" 6"

RTD Element Type

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 0 4 Example "B" is 4" = 004

B
F A B

"U" Tip Diameter


Flush Tip 0.188" 0.250"

G
A B C D E F

Termination Type
3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack Connectors can only be installed on 2 & 3 wire configuration RTDs.

E RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
RED

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Rigid Melt Bolt RTD. Mineral Insulated
Model Code: 2K
Tip Diameter 1/2" x 20 UNF
304 Stainless Steel Bar 2 1/4" U
NORDIC SENSORS

Operating Temperature: -200 C to +500 C

Mineral insulated 316SS sensor tip. Model A B C D E F

2K
A
1 2 3

Melt Bolt Length " L "


3" 4" 6"

RTD Element Type

F
A B C D E F

Termination Type
3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack Connectors can only be installed on 2 & 3 wire configuration RTDs.

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

B
F A B

"U" Tip Diameter


Flush Tip 0.188" 0.250"

E RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
RED

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Fixed Melt Bolt RTD. Mineral Insulated
Model Code: 3K
1/2" -20 UNF
NORDIC SENSORS

Operating Temperature: -200 C to +500 C

Mineral insulated 316SS sensor tip. Model A B C D E


F

3K
A
1 2 3

Melt Bolt Length " L "


3" 4" 6"

D RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 4 Example "B" is 4" = 04

B
F A B

"U" Tip Diameter


Flush Tip 0.188" 0.250"

G
A B C D E F

Termination Type
3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack Connectors can only be installed on 2 & 3 wire configuration RTDs.

E RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
RED

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Plastic Industry RTD's


Adjustable Melt Bolt RTD.
Model Code: 4K
1/2" -20 UNF Operating Temperature: -200 C to +500 C Brass Compression Fitting
NORDIC SENSORS

L
A B C

Mineral insulated 316SS tip. Model D E


F

4K
A
1 2 3

Melt Bolt Length " L "


3" 4" 6"

RTD Element Type

B
F A B

"U" Tip Diameter


Flush Tip 0.188" 0.250"

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 4 Example "B" is 4" = 04

G E RTD Wire Connection


A B C 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
RED

Termination Type
3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack Connectors can only be installed on 2 & 3 wire configuration RTDs.

C
1 2 3 4 5 6

Insertion Depth " U "


Flush 0.125" 0.250" 0.500" 0.750" 1"

2 Wire Configuration 4 Wire Configuration


RED RED RED

A B C D E F

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Process Industry Thermocouples


Mineral Insulated Thermocouple With Plastic Handle
3 mm O.D 26 Gauge Wire, P.V.C Coiled Cord Black Nylon Probe Handle

4.75"

B
Maximum operating temperature 900 F or 500 C.

Steps To Follow: Model:

1.

2.

3.

4.

5.

6.

L1
Probe Tip Option
R D Radius Tip Style Drill Tip Style

1.

4.
A B C D E

Coiled Cord "B" Dimension


Retracted Length 12" 24" 32" 60" 96" Extended Length 48" to 60" 120" 180" 30 ft 45 ft

2.

Termination Type
1 3" Split Leads & 1/2" Bare Ends. 2 Mini Male Plug

5.

1 2 3

J K T

Calibration
(+) Iron Vs. (-) Constantan (+) Ni.-Chromium Vs. (-) Ni.-Aluminum (+) CU. Copper Vs. (-) Cu.-Ni. Nickel

For all other calibrations contact factory for availability.

3.

"A" Dimension 0 4 "A"= _____"


Length In Inches

6.

Junction
G U Grounded Ungrounded

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Straight Thermocouple Elements
Model Code: M1
Outside Diameter Epoxy Potting
NORDIC SENSO RS

Operating Temperature: -200 C to +1000 C Max.

Optional Male Connector

Optional Female Connector


NORDIC SENSORS

U Termination 3/8" or 3"


Model: A B C D E F

M1
A
1 2 3 4 5 6 7 8

Outside Diameter
0.020" 0.040" 0.063" 0.125" 0.188" 0.250" 0.315" 0.375"

D
A B C D E F G H I J

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

F
Element Description
Single Duplex Triplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D T F Q

U H R I S

E M V

B
A B C D

Sheath Material
304 Stainless 316 Stainless 310 Stainless Inconel 600

G
Calibration
1 2 3 4 5 6 7 8

Termination

E
1 2 3 4 5

"U" Dimension

Standard Special Limits of Limits of Error Error

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

3/8" Split bare leads. 3" Split & Color Coded leads. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


General Purpose Thermocouple
Outside Dimension 3/8" O.D. Transition Epoxy Potting 275C Max. Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

Model Code: M2

2"

3 1/2"

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H I

M2
A
1 2 3 4 5 6 7 8

Outside Diameter
0.020" 0.040" 0.063" 0.125" 0.188" 0.250" 0.315" 0.375"

D
A B C D E F G H I N

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F

Cable Insulation Description

Sheath Material

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

E
1 2 3 4 5

Calibration

Standard Special Limits of Limits of Error Error

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

I
1 2 3 4 5 6 7 8

Termination
3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

F
Element Description
Single Duplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D F

U H I

E M

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


General Purpose Thermocouple: 45 Deg. Bend
1 1/2" 3/8" O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

Model Code: M3

U
45 Deg.

2"

3 1/2"

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H I

M3
A
1 2 3 4 5 6 7 8

Outside Diameter
0.020" 0.040" 0.063" 0.125" 0.188" 0.250" 0.315" 0.375"

D
A B C D E F G H I N

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F

Cable Insulation Description

Sheath Material

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

E
1 2 3 4 5

Calibration

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

Standard Special Limits of Limits of Error Error

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

I
1 2 3 4 5 6 7 8

Termination
3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

F
Single Duplex

Junction Styles
Exposed
Common Isolated

Element Grounded Ungrounded Description Common Common Isolated


G D F U H

E I M

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


General Purpose Thermocouple: 90 Deg. Bend
1 1/2"
3/8" O.D. Transition Stress Relief Spring Operating Temperature: -200 C to +1000 C Max.

Model Code: M4
B
3 1/2"

5/8"
90 Deg.

2"

U
Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H I

M4
A
1 2 3 4 5 6 7 8

Outside Diameter
0.020" 0.040" 0.063" 0.125" 0.188" 0.250" 0.315" 0.375"

D
A B C D E F G H I N

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F

Cable Insulation Description

Sheath Material

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

E
1 2 3 4 5

Calibration

Standard Special Limits of Limits of Error Error

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

I
1 2 3 4 5 6 7 8

Termination
3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

F
Single Duplex

Junction Styles
Exposed
Common Isolated

Element Grounded Ungrounded Description Common Common Isolated


G D F U H

E I M

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Metric Straight Thermocouple Elements
Model Code: M5
Outside Diameter Epoxy Potting
NORDIC SENSO RS

Operating Temperature: -200 C to +1000 C Max.

Optional Male Connector

Optional Female Connector


NORDIC SENSORS

U Termination 10mm or 75mm


Model: A B C D E

M5
A
1 2 3 4 5 6 7 8 9

Outside Diameter
0.5mm 1mm 1.5mm 2mm 3mm 4mm 5mm 6mm 8mm

E C
"U" Dimension
Element Description
Single Duplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D F

U H I

E M

Specify " U " Length 1 5 0 In MM Example "U" is 150mm= 150

F B
A B C D

Termination
10mm Split bare leads.
75mm Split & Color Coded leads.

Sheath Material
304 Stainless 316 Stainless 310 Stainless Inconel 600

D
1 2 3 4 5

Calibration

Standard Special Limits of Limits of Error Error

J K T E N

6 7 8 9 10

J K T E N

1 2 3 4 5 6 7 8

Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Metric General Purpose Thermocouple
Outside Dimension 6 mm O.D. Transition Epoxy Potting 275C Max. Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

Model Code: M6

50 mm

90 mm

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

M6
A
1 2 3 4 5 6 7 8

Outside Diameter
0.5 mm 1 mm 1.5 mm 2 mm 3 mm 4 mm 6 mm 8 mm

"U" Dimension

"B" Dimension

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G D
Calibration
A B C D E F

Cable Insulation Description

Sheath Material

Standard Special Limits of Limits of Error Error

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

1 2 3 4 5

J K T E N

6 7 8 9 10

J K T E N

H
1 2 3 4 5 6 7 8

Termination
75 mm Split Leads & 15 mm bare ends. 75 mm Split Leads & Spade Lugs.

E
Element Description
Single Duplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D F

U H I

E M

Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Metric General Purpose Thermocouple: 45 Deg. Bend
40mm 6mm O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

Model Code: M7

U
45 Deg.

50mm

90mm

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

M7
A
1 2 3 4 5 6 7 8

Outside Diameter
0.5 mm 1 mm 1.5 mm 2 mm 3 mm 4 mm 6 mm 8 mm

"U" Dimension

"B" Dimension

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G D
1 2 3 4 5

Calibration

Cable Insulation Description

Standard Special Limits of Limits of Error Error

Sheath Material

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

J K T E N

6 7 8 9 10

J K T E N

A B C D E F

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

H
1 2 3 4 5 6 7 8

Termination
75 mm Split Leads & 15 mm bare ends. 75 mm Split Leads & Spade Lugs.

E
Single Duplex

Junction Styles
Exposed
Common Isolated

Element Grounded Ungrounded Description Common Common Isolated


G D F U H

E I M

Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Metric General Purpose Thermocouple: 90 Deg. Bend
40mm 6mm O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

Model Code: M8

9.5mm 90 Deg.

50mm

90mm

U
Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

M8
A
1 2 3 4 5 6 7 8

Outside Diameter
0.5 mm 1 mm 1.5 mm 2 mm 3 mm 4 mm 6 mm 8 mm

"U" Dimension

"B" Dimension

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G D
1 2 3 4 5

Calibration

Cable Insulation Description

Standard Special Limits of Limits of Error Error

Sheath Material

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

J K T E N

6 7 8 9 10

J K T E N

A B C D E F

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

H
1 2 3 4 5 6 7 8

Termination
75 mm Split Leads & 15 mm bare ends. 75 mm Split Leads & Spade Lugs.

E
Element Description
Single Duplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D F

U H I

E M

Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Hex Bushing Style Thermocouple
Model Code: N1
Outside Diameter Process Connection
Operating Temperature: -200 C to +1000 C Max.

Epoxy Potting: 275 C Max.

U Model Code: N2
Outside Diameter Process Connection

1"

B
Epoxy Potting: 275 C Max.

3 1/2"

U
Model:

1" C D E F G

B
H

3 1/2" I J

N1 N2

A
1 2 3 4 5 6 7

Outside Diameter
0.063" 0.125" 0.188" 0.250" 0.315" 0.375" 0.500"

E
1 2 3

Process Connection
1/4" NPT 1/2" NPT 3/4" NPT

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

Sheath Material

F
1 2 3 4 5

I
Calibration
A B C D E F

Cable Insulation Description


20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC .210" O.D. Flexible Armor Cable

Standard Special Limits of Limits of Error Error

"U" Dimension

Specify " U " Length In Inches 0 0 6


Example "U" is 6" = 006

J K T E N

6 7 8 9 10

J K T E N

J
1 2 3 4 5 6 7 8

Termination

D
A B C D E F

"U" Fractional

Dimension
0.125" 0.250" 0.375" 0.500" 0.750" None

G
Element Description
Single Duplex Triplex

Junction Styles
Grounded
Common

Ungrounded

Exposed

Common Isolated Common Isolated

G D T F Q

U H R I S

E M V

3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Compression Fitting Mounting Style
Connection Head
Conduit Opening Grounded Ungrounded Exposed Operating Temperature: -200 C to +1000 C Max.

Model Code: N3
Head Connection Compression Fitting *( Optional ) 20 Gage Fiberglass Leads

Outside Diameter 3 1/2"

1"

Epoxy Potting 275 C Max.

3 5/8" Model: A B C

U
*See Accessories section for compression fitting information.

3"
F G H I J

N3
A
1 2 3 4 5 6 7

Outside Diameter
0.063" 0.125" 0.188" 0.250" 0.315" 0.375" 0.500"

D
A B C D E F G H I J

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

G
1 2 3

Head Connection
1/4" NPT 1/2" NPT 3/4" NPT

H
A B C D E F G

Connection Head Model

Sheath Material

E
1 2 3 4 5

Calibration
Special

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

Standard

limits of error limits of error

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

"U" Dimension

J K T E N

6 7 8 9 10

J K T E N

I
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
Single Duplex Triplex

Junction Styles
Exposed
Common Isolated

Element Grounded Ungrounded Description Common Common Isolated


G D T F Q U H R

Connection Head Options

E I S M V

N None T 4-20mA Transmitter X No Terminal Block

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple


Hex Nipple Style
Connection Head
Conduit Opening Grounded Ungrounded Exposed Operating Temperature: -200 C to +1000 C Max.

Model Code: N4
Process Connection 20 Gage Fiberglass Leads

3 1/2"

Outside Diameter

1 3/4"

Epoxy Potting 275 C Max

3 5/8" Model: A B C D E

U
F G H

3"
I J

N4
A
1 2 3 4 5 6 7

Outside Diameter
0.063" 0.125" 0.188" 0.250" 0.315" 0.375" 0.500"

D
A B C D E F G H I J

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

G
1 2 3

Process Connection
1/4" NPT 1/2" NPT 3/4" NPT

H
A B C D E F G

Connection Head Model

Sheath Material

E
1 2 3 4 5

Calibration
Special

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

A 304 Stainless B 316 Stainless C 310 Stainless D Inconel 600

Standard

limits of error limits of error

I
1 2 3

"U" Dimension

J K T E N

6 7 8 9 10

Conduit Opening
None 1/2" NPT 3/4" NPT

J K T E N

J
Exposed

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
Element Description
Single Duplex Triplex

Junction Styles
Grounded
Common

Connection Head Options


None No Terminal Block Spring Loaded 4-20mA Transmitter Options S & T Options S & B

Ungrounded

Common Isolated Common Isolated

G D T F Q

U H R I S

E M V

N B S T R Q

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple & Thermowell Assembly Standard Stepped Threaded Thermowell
Model Code: P1
U
0.5" 2.5" Process Connection U + 1.75" All Thermowell Assemblies Are Spring Loaded. C A B 1/2" NPT Hex Nipple Connection Head Model
Operating Temperature: -200 C to +1000 C Max.

Conduit Opening

3"

Model:

P1
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

C
1 2 3 4 5

Calibration

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

Standard Special Limits of Limits of Error Error

J K T E N

6 7 8 9 10

J K T E N

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

B
1 2 3 4 5

Sheath Material
304 Stainless 316 Stainless Inconel 600 Carbon Steel Solid Teflon

D
Single

Junction Styles
Ungrounded
Common Isolated

G
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

Element Grounded Description Common


G D T Duplex Triplex

U F Q H R

For all other materials contact factory for availability.

Connection Head Options

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple & Thermowell Assembly Standard Straight Threaded Thermowell
Model Code: P2
U
0.765" Process Connection U + 1.75" All Thermowell Assemblies Are Spring Loaded. B C A D
1/2" NPT Hex Nipple Operating Temperature: -200 C to +1000 C Max.

Conduit Opening

3"

Connection Head Model E F G H

Model:

P2
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

C
1 2 3 4 5

Calibration

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

Standard Special Limits of Limits of Error Error

J K T E N

6 7 8 9 10

J K T E N

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

B
1 2 3 4 5

Sheath Material
304 Stainless 316 Stainless Inconel 600 Carbon Steel Solid Teflon

D Junction Styles
Element Grounded Description Common
Single Duplex Triplex G D T F Q Ungrounded
Common Isolated

G
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

U H R

For all other materials contact factory for availability.

H
N B T

Connection Head Options


None No Terminal Block 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple & Thermowell Assembly Standard Tapered Threaded Thermowell
Model Code: P3
U
0.625" Operating Temperature: -200 C to +1000 C Max.

Conduit Opening

3"

Process Connection U + 1.75" All Thermowell Assemblies Are Spring Loaded. Model: A B C

1/2" NPT Hex Nipple

Connection Head Model

P3
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

C
1 2 3 4 5

Calibration

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

Standard Special Limits of Limits of Error Error

J K T E N

6 7 8 9 10

J K T E N

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

B
1 2 3 4 5

Sheath Material
304 Stainless 316 Stainless Inconel 600 Carbon Steel Solid Teflon

D
Single

Junction Styles
Ungrounded
Common Isolated

G
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

Element Grounded Description Common


G D T Duplex Triplex

U F Q H R

For all other materials contact factory for availability.

Connection Head Options

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated Thermocouple & Thermowell Assembly Nipple-Union-Nipple-Thermowell Style


Model Code: P4
U
0.765" Process Connection Operating Temperature: -200 C to +1000 C Max.

Conduit Opening

6"

U + 1.75" All Thermowell Assemblies Are Spring Loaded. Model: A B C D

1/2" NPT Pipe Nipples

Connection Head Model

P4
A
1 2 3

Thermowell Type
Stepped Straight Tapered

Sheath Material

F
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

1 304 Stainless 2 316 Stainless 3 Inconel 600 4 Carbon Steel 5 Solid Teflon For all other materials contact factory for availability.

G
A B C D E F G

Connection Head Model

D B
A B C D E F G H "U" Fractional

Calibration

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

Standard Special Limits of Limits of Error Error

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

1 2 3 4 5

J K T E N

6 7 8 9 10

J K T E N

H
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

E
Single

Junction Styles
Ungrounded
Common Isolated

For all other U lengths contact factory for availability.

Element Grounded Description Common


G D T Duplex Triplex

I
N B T

Connection Head Options


None No Terminal Block 4-20mA Transmitter

U F Q H R

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Process Industry RTD's


Hand Held RTD Probe
1/8" O.D Black Nylon Probe Handle Low temperature application -200 C To +100 C 26 Gauge Wire, P.V.C Coiled Cord

4.75"

B
Operating Temperature: -200 C to +250 C

Steps To Follow: Model:

1.

2.

3.

4.

5.

6.

1L
Probe Tip Option
R D Radius Tip Style Drill Point Style

1.

4.
A B C D E

Coiled Cord "B" Dimension


Retracted Length 12" 24" 32" 60" 96" Extended Length 48" to 60" 120" 180" 360" 540"

2.

Termination Type
1 3" Split Leads & 1/2" Bare Ends. 2 Mini Male Plug (2 wire configuration only)

5.

RTD Element Type


Ohms 1 x Pt100 2 x Pt100 1 x Pt1000 2 x Pt1000 Class A 2 4 6 8 Class B 1 3 5 7

Temperature Coefficient: 0.00385 Platinum element IEC 751

3.

"A" Dimension 0 4 "A"= _____"


Length In Inches

6.

RTD Wire Connection


A B 2 Wire Configuration 3 Wire Configuration
3 Wire Configuration
RED RED RED

2 Wire Configuration

RED

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Straight RTD Elements
Ceramic RTD Element
Operating Temperature: -200 C to +500 C Max.

Model Code: 1M

Optional Male Connector


NORDIC SENSORS

Flat Tip Construction For Quicker Response Outside Diameter Epoxy Potting

Optional Female Connector

Termination 3/8" or 3" D E F

Model:

NORDIC SENSORS

1M
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

D
A B C D E F G H I N

"U" Fractional

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration
RED RED WHITE WHITE

B
A B

Sheath Material
304 Stainless 316 Stainless

RTD Element Type

WHITE

"U" Dimension

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

G
1 2 3 4 5 6

Termination Type
3/8" Split Bare Ends. 3" Split & Color Coded Leads. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

Connectors can only be installed on 2 & 3 wire configuration RTDs.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


General Purpose Type
Ceramic RTD Element 3/8" O.D. Transition Outside Dimension Epoxy Potting 275C Max. Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 2M

U
Model: A B C D

2" E F

B
G

3 1/2" H I

2M
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

RTD Element Type

B
A B

Sheath Material
304 Stainless 316 Stainless

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F G H

Cable Insulation Description


24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

D
A B C D E F G H I N

"U" Fractional

2 Wire Configuration 4 Wire Configuration


RED RED RED

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

I
1 2 3 4 5 6

Termination
3 1/2" Split leads & bare ends 3 1/2" Split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


General Purpose Type: 45 Deg. Bend
1 1/2" 3/8" O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 3M

U
45 Deg.

2"

3 1/2"

Ceramic RTD Element Model: A B C D E F G H I

3M
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

RTD Element Type

B
A B

Sheath Material
304 Stainless 316 Stainless

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F G H

Cable Insulation Description


24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

D
A B C D E F G H I N

"U" Fractional

2 Wire Configuration 4 Wire Configuration


RED RED RED

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

I
1 2 3 4 5 6

Termination
3 1/2" Split leads & bare ends 3 1/2" Split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


General Purpose Type: 90 Deg. Bend
1 1/2" 3/8" O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 4M
B
3 1/2"

5/8"
90 Deg.

2"

Ceramic RTD Element

Model:

4M
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

RTD Element Type

B
A B

Sheath Material
304 Stainless 316 Stainless

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

H
A B C D E F G H

Cable Insulation Description


24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

D
A B C D E F G H I N

"U" Fractional

2 Wire Configuration 4 Wire Configuration


RED RED RED

Dimension
0.125" 0.188" 0.250" 0.315" 0.375" 0.500" 0.625" 0.750" 0.875" None

I
1 2 3 4 5 6

Termination
3 1/2" Split leads & bare ends 3 1/2" Split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Metric Straight RTD Elements
Ceramic RTD Element
Operating Temperature: -200 C to +500 C Max.

Model Code: 5M

Optional Male Connector


NORDIC SENSORS

Flat Tip Construction For Quicker Response Outside Diameter Epoxy Potting

Optional Female Connector

U
Compression fittings are sold seperatly. See accessory section. Model: A B C

Termination 10 mm or 75 mm D E

NORDIC SENSORS

5M
A
1 2 3 4

Outside Diameter
2 mm 3 mm 4 mm 6 mm

E C
"U" Dimension
Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100 A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration

B
A B

Sheath Material
304 Stainless 316 Stainless

RED RED

WHITE WHITE

RTD Element Type

WHITE

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum Element IEC 751

Termination Type

10 mm Split Bare Ends. 1 2 75 mm Split & Color Coded Leads. Standard Male Plug 3 Standard Female Jack 4 Mini Male Plug 5 6 Mini Female Jack Connectors can only be installed on 2 & 3 wire configuration RTDs.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Metric General Purpose Type
Ceramic RTD Element 6 mm O.D. Transition Outside Dimension Epoxy Potting 275C Max. Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 6M
Compression fittings are sold seperatly. See accessory section.

U
Model: A B C

50 mm D E

B
F

90 mm G H

6M
A
1 2 3 4

Outside Diameter
2 mm 3 mm 4 mm 6 mm

D RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G
A B C D E F G H

Cable Insulation Description

Sheath Material

A 304 Stainless B 316 Stainless

E
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

2 Wire Configuration

"U" Dimension

4 Wire Configuration
RED RED RED

H
1 2 3 4 5 6

Termination

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

3 Wire Configuration
RED RED WHITE WHITE

75 mm split leads & 15 mm bare ends 75 mm split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Metric General Purpose Type: 45 Deg. Bend
40mm 6mm O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 7M

U
45 Deg.

50mm

90mm

Ceramic RTD Element

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

7M
A
1 2 3 4

Outside Diameter
2 mm 3 mm 4 mm 6 mm

D RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G
A B C D E F G H

Cable Insulation Description

B
A B

Sheath Material
304 Stainless 316 Stainless

E
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

2 Wire Configuration

"U" Dimension

4 Wire Configuration
RED RED RED

H
1 2 3 4 5 6

Termination

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

3 Wire Configuration
RED RED WHITE WHITE

75 mm split leads & 15 mm bare ends 75 mm split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Metric General Purpose Type: 90 Deg. Bend
40mm 6mm O.D. Transition Stress Relief Spring
Operating Temperature: -200 C to +500 C Max.

Model Code: 8M
B
90mm

16mm
90 Deg.

50mm

Ceramic RTD Element

Compression fittings are sold seperatly. See accessory section. Model: A B C D E F G H

8M
A
1 2 3 4

Outside Diameter
2 mm 3 mm 4 mm 6 mm

D RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

"B" Dimension

Specify " B " Length 0 2 In Meters Example "B" is 2 Meters = 02

G
A B C D E F G H

Cable Insulation Description

B
A B

Sheath Material
304 Stainless 316 Stainless

E
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

2 Wire Configuration

"U" Dimension

4 Wire Configuration
RED RED RED

H
1 2 3 4 5 6

Termination

Specify " U " Length 1 0 0 In mm Example "U" is 100 mm = 100

3 Wire Configuration
RED RED WHITE WHITE

75 mm split leads & 15 mm bare ends 75 mm split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD


Hex Bushing Style RTD
Process Connection
Operating Temperature: -200 C to +500 C Max.

Model Code: 1N
Outside Diameter

Epoxy Potting: 275 C Max.

U Model Code: 2N
Outside Diameter Process Connection

1"

B
Epoxy Potting: 275 C Max.

3 1/2"

U
Model: A B C D

1" E F G

B
H I

3 1/2" J

1N 2N

A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

E
1 2 3

Process Connection
1/4" NPT 1/2" NPT 3/4" NPT

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

B
A B

Sheath Material
304 Stainless 316 Stainless

RTD Element Type

I
A B C D E F G H

"U" Dimension

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8


Temperature Coefficient: 0.00385 Platinum element IEC 751

Cable Insulation Description


24 gage, Stranded, Fiberglass 24 gage, Fiberglass, Metal Braid .281" O.D. Flexible Armor Cable .210" O.D. Flexible Armor Cable 24 gage, Stranded, Teflon 24 gage, Stranded, Sheilded, Teflon 24 gage, Stranded, PVC 24 gage, Stranded, Sheilded, PVC

Specify " U " Length In Inches 0 0 6


Example "U" is 6" = 006

G
A B C

D
A B C D E F

"U" Fractional

Dimension
0.125" 0.250" 0.375" 0.500" 0.750" None

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

J
1 2 3 4 5 6

Termination

2 Wire Configuration 4 Wire Configuration


RED RED RED

3 Wire Configuration
RED RED WHITE WHITE

3 1/2" Split leads & bare ends 3 1/2" Split leads & No.10 spade lugs Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F ) Connectors can only be installed on 2 & 3 wire configuration RTDs.

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD Probe Assembly


Compression Fitting Mounting Style
Connection Head
Conduit Opening Ceramic RTD Element
Operating Temperature: -200 C to +500 C Max.

Model Code: 3N
Head Connection 20 Gage Fiberglass Leads

Compression Fitting 3 1/2" Outside Diameter *( Optional )


1" Epoxy Potting 275 C Max

U
3 5/8" Model: A B Compression fittings are sold seperatly. See accessory section. C D E G H F

3"
I J

3N
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

RTD Element Type

G
1 2 3

Head Connection
1/4" NPT 1/2" NPT 3/4" NPT

B
A B

Sheath Material
304 Stainless 316 Stainless

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

H
A B C D E F

Connection Head Model

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel

I
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

D
A B C D E F G

"U" Fractional

2 Wire Configuration 4 Wire Configuration


RED RED RED

Dimension
0.125" 0.250" 0.375" 0.500" 0.625" 0.750" None

3 Wire Configuration
RED RED WHITE WHITE

Connection Head Options

WHITE

N None T 4-20mA Transmitter X No Terminal Block

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD Probe Assembly


Hex Nipple Process Style
Connection Head
Conduit Opening Operating Temperature: -200 C to +500 C Max.

Ceramic RTD Element

Model Code: 4N
Process Connection 20 Gage Fiberglass Leads

3 1/2"

Outside Diameter

1 3/4"

Epoxy Potting 275 C Max

3 5/8" Model: A B C D

U
E F G H

3"
I J

4N
A
1 2 3 4

Outside Diameter
0.079" 0.125" 0.188" 0.250"

RTD Element Type

G
1 2 3

Process Connection
1/4" NPT 1/2" NPT 3/4" NPT

B
A B

Sheath Material
304 Stainless 316 Stainless

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

H
A B C D E F G

Connection Head Model

"U" Dimension

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

F
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosition Proof

I
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

D
A B C D E F G

"U" Fractional

2 Wire Configuration 4 Wire Configuration


RED RED RED

Dimension
0.125" 0.250" 0.375" 0.500" 0.625" 0.750" None

J
N B S T R Q

Connection Head Options


None No Terminal Block Spring Loaded 4-20mA Transmitter Options S & T Options S & B

3 Wire Configuration
RED RED WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD & Thermowell Assembly Standard Stepped Threaded Thermowell
Model Code: 1P
U
0.5" Operating Temperature: -200 C to +500 C Max.

Conduit Opening

3"

2.5"

Process Connection

U + 1.75" All Thermowell Assemblies Are Spring Loaded. C B A

1/2" NPT Hex Nipple D E

Connection Head Model

Model:

1P
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

RTD Element Type

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

D
A B C

B
1 2 3

Sheath Material
304 Stainless 316 Stainless Solid Teflon

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

G
RED

Conduit Opening
None 1/2" NPT 3/4" NPT

2 Wire Configuration 4 Wire Configuration


RED RED

1 2 3

For all other materials contact factory for availability.

3 Wire Configuration
RED RED WHITE WHITE

Connection Head Options

WHITE

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD & Thermowell Assembly Standard Straight Threaded Thermowell
Model Code: 2P
U
0.765" Process Connection U + 1.75" All Thermowell Assemblies Are Spring Loaded. C B A 1/2" NPT Hex Nipple D E Connection Head Model F G H
Operating Temperature: -200 C to +500 C Max.

Conduit Opening

3"

Model:

2P
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

C RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

D
A B C

B
1 2 3

Sheath Material
304 Stainless 316 Stainless Solid Teflon

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

G
RED

Conduit Opening
None 1/2" NPT 3/4" NPT

2 Wire Configuration 4 Wire Configuration


RED RED

1 2 3

For all other materials contact factory for availability.

3 Wire Configuration
RED RED WHITE WHITE

Connection Head Options

WHITE

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD & Thermowell Assembly Standard Tapered Threaded Thermowell
Model Code: 3P
U
0.625" Operating Temperature: -200 C to +500 C Max.

Conduit Opening

3"

Process Connection U + 1.75" All Thermowell Assemblies Are Spring Loaded. C B A 1/2" NPT Hex Nipple Connection Head Model

Model:

3P
A
A B C D E F G H "U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

RTD Element Type

E
1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751

F
A B C D E F G

Connection Head Model


None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

For all other U lengths contact factory for availability.

D
A B C

B
1 2 3

Sheath Material
304 Stainless 316 Stainless Solid Teflon

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

G
RED

Conduit Opening
None 1/2" NPT 3/4" NPT

2 Wire Configuration 4 Wire Configuration


RED RED

1 2 3

For all other materials contact factory for availability.

3 Wire Configuration
RED RED WHITE WHITE

Connection Head Options

WHITE

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Mineral Insulated RTD & Thermowell Assembly Nipple-Union-Nipple-Thermowell Style


Model Code: 4P
U
0.765" Operating Temperature: -200 C to +500 C Max.

Conduit Opening

6"

Process Connection U + 1.75"


1/2" NPT Pipe Nipples

Connection Head Model

Model:

All Thermowell Assemblies Are Spring Loaded. D A B C

4P
A
1 2 3

Thermowell Type
Stepped Straight Tapered "U" Fractional

F D RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 3 4 2 x Pt100 5 1 x Pt1000 6 2 x Pt1000 7 8 Temperature Coefficient: 0.00385 Platinum element IEC 751 1 2 3

Process Connection
1/2" NPT 3/4" NPT 1" NPT

B
A B C D E F G H

G
A B C D E F G

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

Connection Head Model

E
A B C

2 Wire Configuration 3 Wire Configuration 4 Wire Configuration


RED

RTD Wire Connection

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Polypropylene: FDA Appr. Cast Iron: Standard 316 Stainless Steel Explosion Proof

H
RED

For all other U lengths contact factory for availability.

Conduit Opening
None 1/2" NPT 3/4" NPT

2 Wire Configuration 4 Wire Configuration


RED RED

1 2 3

C
1 2 3

Sheath Material
304 Stainless 316 Stainless Solid Teflon

3 Wire Configuration
RED RED WHITE WHITE

Connection Head Options

WHITE

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Bare Thermocouple Elements
1 Butt-Weld

Model: Q1
Wire Gage, 8,14 or 20 AWG Bare Element Thermocouple Color Coded Bare Ends
BARE

2 Parallel-Weld

Twist-Weld

SINGLE

2"

Steps: Model:

Q1
C
A B

Junction Weld Description

Calibration

"U" Dimension

A Butt-weld B Parallel-weld C Twist-weld

Standard Special Limits of Limits of Error Error

Specify " U " Length In Inches 0 1 8 Example "U" is 18" = 018

J K

C D

J K

B
Model 1 2 3

Thermocouple Wire Gage


Wire Gage 8 14 20 Description No Ceramic Insulators, Bare Thermocouple Element No Ceramic Insulators, Bare Thermocouple Element No Ceramic Insulators, Bare Thermocouple Element

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Thermocouple Elements With Ceramic Insulators
1 Butt-Weld

Model: Q2
ROUND ROUND OVAL

Mullite Ceramic Insulators

2 Parallel-Weld

C
DUAL SINGLE SINGLE

U
Ball & Socket Ceramic Insulators

2" Color Coded Bare Ends

BALL & SOCKET

Twist-Weld
SINGLE

U
Steps: Model: A B C

2" D

Q2
C
A B

Junction Weld Description

Calibration

"U" Dimension

A Butt-weld B Parallel-weld C Twist-weld

Standard Special Limits of Limits of Error Error

Specify " U " Length In Inches 0 1 8 Example "U" is 18" = 018

J K

C D

J K

B Wire Gage & Ceramic Insulator Selection


Model 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Wire Gage Shape "C" Length Round 8 1" Round 8 3" 8 1" Oval 8 Oval 3" Round 14 1" Round 14 3" Round 14 1" 14 Oval 1" 14 Oval 3" Round 1" 20 Round 20 3" Ball & Socket 8 0.260" Ball & Socket 0.200" 14 Ball & Socket 20 0.170" Outside Diameter 0.468" 0.500" 0.435" x 0.250" 0.562" x 0.312" 0.250" 0.281" 0.312" 0.312" x 0.187" 0.375" x 0.217" 0.187" 0.225" 0.260" 0.200" 0.170" Elements Single Single Single Single Single Single Dual Single Single Single Single Single Single Single

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Angle Thermocouple Elements With Ceramic Insulators
1 Butt-Weld

Model: Q3

Ball & Socket Ceramic Insulators

2 Parallel-Weld
ROUND ROUND OVAL

U = Hot Leg
Mullite Insulators

B = Cold Leg

Twist-Weld

DUAL

SINGLE

SINGLE

2" Color Coded Bare Ends


Steps: Model: A B C D E

Q3
Junction Weld

A Description
A Butt-weld B Parallel-weld C Twist-weld

C
A B

Calibration

D Dimension
Specify " U " Length In Inches 1 2 Example "U" is 12" = 12

"U" Hot

E Dimension
Specify " B " Length In Inches 1 8 Example "U" is 18" = 18

"B" Cold

Standard Special Limits of Limits of Error Error

J K

C D

J K

B Wire Gage & Ceramic Insulator Selection


Model 1 2 3 4 5 6 7 8 9 10 11 Wire Gage 8 8 8 8 14 14 14 14 14 20 20 Shape Round Round Oval Oval Round Round Round Oval Oval Round Round "C" Length 1" 3" 1" 3" 1" 3" 1" 1" 3" 1" 3" Outside Diameter 0.468" 0.500" 0.435" x 0.250" 0.562" x 0.312" 0.250" 0.281" 0.312" 0.312" x 0.187" 0.375" x 0.217" 0.187" 0.225" Elements Single Single Single Single Single Single Dual Single Single Single Single

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Thermocouple & Metal Protection Tube Assembly

Model Code: R1
Grounded Junction Metal Protection Tube O.D. Mullite Insulators 1.775"

Conduit Opening

U
Process Connection Steps: Model: A B C D E F G H I J

R1
A
Outside Diameter

E
A B

Calibration

H
A B C D E F G

Connection Head Model

1 1/4" NPT Pipe 2 1/2" NPT Pipe 3 3/4" NPT Pipe

Standard Special Limits of Limits of Error Error

1 Schedule 20 2 Schedule 40 3 Schedule 80

Wall Thickness

J K

C D

J K

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

Junction I
1 2 3

C
A B C D E

Carbon Steel 304 SS 316 SS Inconel 600 Ceramic Coated

Sheath Material

Wire Gounded Ungounded Gage Single Dual Single Dual 8 10 1 4 7 14 11 2 5 8 20 12 3 6 9

Conduit Opening
None 1/2" NPT 3/4" NPT

"U" Dimension

G
1 2 3 4

Process Connection
None 1/2" NPT 3/4" NPT 1" NPT

Connection Head Options

Specify " U " Length In Inches 0 0 6 Example "U" is 6" = 006

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Angle Thermocouple & Metal Protection Tube Assembly

Model Code: R2
Cross Section

B
1/2" NPT Steel Pipe Connection Head

Process Connection

A U

Conduit Opening

Metal Protection Tube


Steps: Model: A B C D E F G H I J K L

R2
Protection Tube O.D.
1/4" Pipe 1/2" Pipe 3/4" Pipe

A
A B C

E
A B

Calibration

I
A B C D E F G

Standard Special Limits of Limits of Error Error

1 Schedule 20 2 Schedule 40 3 Schedule 80

Wall Thickness

J K

C D

J K

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

Connection Head Model

F
8 14 20 1 2 3

Junction
4 5 6 7 8 9 10 11 12

J
1 2 3

Wire Gounded Ungounded Gage Single Dual Single Dual

Conduit Opening
None 1/2" NPT 3/4" NPT

C
A B C D E

Carbon Steel 304 SS 316 SS Inconel 600 Ceramic Coated

Sheath Material

Connection Head Options

G
A B C D

Process Connection
None 1/2" NPT 3/4" NPT 1" NPT

N None B No Terminal Block T 4-20mA Transmitter

"A" Dimension

"U" Dimension

"B" Insertion

Specify " A " Length In Inches 0 1 2 Example "A" is 12" = 012

Specify " U " Length In Inches 0 0 8 Example "U" is 8" = 008

Specify " B " Length In Inches 0 1 8 Example "B" is 18" = 018

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Thermocouple & Metal Protection Tube Assembly

Model Code: R3
Metal Protection Tube Process Connection Mullite Insulators

Conduit Opening

A
D E F G H I J K

Steps: Model:

R3

A
A B C

Protection Tube O.D.


1/4" Pipe 1/2" Pipe 3/4" Pipe

"A" Dimension

Specify " A " Length In Inches 0 1 2 Example "A" is 12" = 012

"U" Dimension

Specify " U " Length In Inches 0 0 8 Example "U" is 8" = 008

E B
Wall Thickness
A B

Calibration

Standard Special Limits of Limits of Error Error

I
A B C D E F G

1 Schedule 20 2 Schedule 40 3 Schedule 80

J K

C D

J K

F
8 14 20 1 2 3

Junction
4 5 6 7 8 9 10 11 12

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

Connection Head Model

C
A B C D E

Carbon Steel 304 SS 316 SS Inconel 600 Ceramic Coated

Sheath Material

Wire Gounded Ungounded Gage Single Dual Single Dual

J
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

Process Connection

A 1/2" NPT Hex Bushing B 3/4" NPT Hex Bushing C 1" NPT Hex Bushing

Connection Head Options

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Thermocouple & Ceramic Protection Tube Assembly

Model Code: S1
Ungrounded Junction Ceramic Protection Tube Mullite Insulators 1.775"

Conduit Opening

U
Process Connection Model: A B C D E F G H I

S1
A
Ceramic Tube Size

D
A B

Calibration

G
A B C D E F G

Connection Head Model

A 1/4" O.D. B 3/8" O.D. C 1/2" O.D. D 11/16" O.D. E 1" O.D.

Standard Special Limits of Limits of Error Error

J K

C D

J K

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

Protection Tube

E
8 14 20

Wire Size
Dual
4 5 6 1 2 3

1 Alumina 1800C Max. 2 Mullite 1600C Max.

Gage Single

H
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

"U" Dimension

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

F
1 2 3 4

Process Connection
None 1/2" NPT 3/4" NPT 1" NPT

Connection Head Options

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

INDUSTRIAL THERMOCOUPLES
Base Metal Thermocouple, Ceramic Protection Tube & Terminal Block Assembly

Model Code: S2
Ceramic Protection Tube Mullite Insulators Metal Sleeve Stainless Steel Compression Fitting Terminal Block

Operating Temperature: +1000 C Max.

2"

U 2"
Base Plate

Model:

S2
A
A B

Ceramic Tube Size


1/4" O.D. 3/8" O.D.

D
A B

Calibration

Terminal Block Description

Standard Special Limits of Limits of Error Error

A Ceramic B Ceramic, Spring Loaded C Plastic, 1" Dia. Micro Head Size

Protection Tube

J K

C D

J K

1 Alumina 1800C Max. 2 Mullite 1600C Max.

E
20 24

Wire Size
Dual
4 5 1 2

"U" Dimension

Gage Single

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

NOBEL METAL THERMOCOUPLES


Bare Element Thermocouples
Model: T1
Bare Element Thermocouple BARE Color Coded Bare Ends

SINGLE

2"

Steps: Model:

T1
Wire Gage
20 Gage 24 Gage 26 Gage 28 Gage

A
A B C D

B
A B C

Calibration

"U" Dimension

Standard Special Limits of Limits of Error Error

Specify " U " Length In Inches 0 1 8 Example "U" is 18" = 018

S R B

D E F

S R B

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

NOBEL METAL THERMOCOUPLES


Nobel Metal Thermocouple Elements With Ceramic Insulators
1 Butt-Weld

Model: T2
ROUND ROUND DUAL SINGLE

2 Parallel-Weld

Alumina Ceramic Insulator 3 Twist-Weld

Color Coded Bare Ends

2"

Steps: Model:

T2
Wire Size
Dual
5 6 7 8 1 2 3 4

A
20 24 26 28

C
A B C

Calibration

"U" Dimension

Gage Single

Standard Special Limits of Limits of Error Error

Specify " U " Length In Inches 0 1 8 Example "U" is 18" = 018

S R B

D E F

S R B

B
A B C

Insulator Diameter
1/8" O.D. 3/16" O.D. 1/4" O.D.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

NOBEL METAL THERMOCOUPLES


Nobel Metal Thermocouple & Metal Protection Tube Assembly

Model Code: T3
Ungrounded Junction Metal Protection Tube O.D. Alumina Insulator 1.775"

Conduit Opening

U
Process Connection Steps: Model: A B C D E F G H I J

T3
A
Outside Diameter

E
A B C

Calibration

H
A B C D E F G

Connection Head Model

1 1/4" NPT Pipe 2 1/2" NPT Pipe 3 3/4" NPT Pipe

Standard Special Limits of Limits of Error Error

1 Schedule 20 2 Schedule 40 3 Schedule 80

Wall Thickness

S R B

D E F

S R B

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

F
20 24 26 28

Wire Size
Dual
5 6 7 8 1 2 3 4

C
A B C D E

Carbon Steel 304 SS 316 SS Inconel 600 Ceramic Coated

Sheath Material

Gage Single

I
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

"U" Dimension

G
1 2 3 4

Process Connection
None 1/2" NPT 3/4" NPT 1" NPT

Connection Head Options

Specify " U " Length 0 6 In Inches Example "U" is 6" = 06

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

NOBEL METAL THERMOCOUPLES


Nobel Metal Thermocouple & Ceramic Protection Tube Assembly

Model Code: T4
Ungrounded Junction Ceramic Protection Tube O.D. 1.775" Alumina Insulator

Conduit Opening

U
Process Connection Model: A B C D E F G H I

T4
A
Ceramic Tube Size

D
A B C

Calibration

G
A B C D E F G

Connection Head Model

1/4" O.D. A B 3/8" O.D. C 1/2" O.D. D 11/16" O.D. E 1" O.D.

Standard Special Limits of Limits of Error Error

S R B

D E F

S R B

None , 3" Split Leads Cast Aluminum: Standard Cast Aluminum: Mini Black Nylon Head Cast Iron: Standard Size 316 Stainless Steel Explosion Proof

Protection Tube

E
20 24 26 28

Wire Size
Dual
5 6 7 8 1 2 3 4

1 Alumina 1800C Max. 2 Mullite 1600C Max.

Gage Single

H
1 2 3

Conduit Opening
None 1/2" NPT 3/4" NPT

"U" Dimension

F
1 2 3 4

Process Connection
None 1/2" NPT 3/4" NPT 1" NPT

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Connection Head Options

N None B No Terminal Block T 4-20mA Transmitter

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

NOBEL METAL THERMOCOUPLES


Nobel Metal Thermocouple, Ceramic Protection Tube & Terminal Block Assembly

Model Code: T5
Ceramic Protection Tube O.D. Alumina Insulator Metal Sleeve Stainless Steel Compression Fitting Terminal Block

Operating Temperature: +1000 C Max.

2"

U 2"
Base Plate

Model:

T5
A
1 2

Ceramic Tube Size


1/4" O.D. 3/8" O.D.

D
A B C

Calibration

Terminal Block Description

Standard Special Limits of Limits of Error Error

A Ceramic B Ceramic, Spring Loaded C Plastic, 1" Dia. Micro Head Size

Protection Tube

S R B

D E F

S R B

A Alumina 1800C Max. B Mullite 1600C Max.

E C
"U" Dimension
Specify " U " Length In Inches 0 6 Example "U" is 6" = 06 20 24 26 28

Wire Size
Dual
5 6 7 8 1 2 3 4

Gage Single

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

SPECIAL THERMOCOUPLE ASSEMBLIES


Flanged Style Tube & Wire Thermocouple Probe
Model Code: Z1
1" Diameter Maximum operating temperature: 900F or 500C

R = 0.144" Mounting Hole

3/4" Model: A
B C

U
D E

1"
F G H

B
I

3 1/2"
J K

Z1
A Diameter
A B C D 1/8" 3/16" 1/4" 5/16"

Outside

E Calibration
J K T White Yellow Blue Red Red Red

1 None 2 Stainless Steel Braid 3 Armor Flexible Cable:


0.280" Outside Diameter

I Protection

Outer Jacket

4 Armor Flexible Cable

"U" B Dimension
Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

F
Single Duplex

Junction Styles
Grounded
Common

0.210" Outside Diameter

Element Description

Ungrounded
Common Isolated

Metal Braid Protection not available on P.V.C insulation cable.

G D C

U I

C
A B C D E F G H

"U" Length Fractional


0" 1/8" 3/16" 1/4" 1/2" 5/8" 3/4" 7/8"

J G
1 2 3 4

Termination
3 1/2" Split leads & bare ends
3 1/2" Split leads & No.10 spade lugs.

Cable Conductor Description


24 Gage, Solid Conductor 24 Gage, 7 Stranded Conductors 20 Gage, Solid Conductor 20 Gage, 7 Stranded Conductors

A B C D E F

Standard Male Plug (350 F) Standard Female Jack (350 F ) Mini Male Plug ( 350 F ) Mini Female Jack (350 F )

"B" Dimension

H
A B C D E

Cable Insulation Description

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

Fiberglass Insulation: 950F / 510C Teflon Insulation: 500F / 260C P.V. C. Insulation: 221F / 105C Teflon, Shielded + Drain Wire P.V.C., Shieded + Drain Wire

K Termination Options
1 None 2 Bx Connector 3 Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

SPECIAL THERMOCOUPLE ASSEMBLIES


Mineral Insulated Thermocouple & Terminal Block Assembly

Model Code: Z2
Stainless Steel Compression Fitting

Operating Temperature: -200 C to +1000 C Max.

Terminal Block

2"

U 1"
Base Plate

Model:

Z2
A
A B C D

Outside Diameter
1/8" O.D. 3/16" O.D. 1/4" O.D. 1/2" O.D.

C
A B C

Calibration

Terminal Block Description

Standard Special Limits of Limits of Error Error

A Ceramic B Ceramic, Spring Loaded C Plastic, Micro Head Size

J K T

D E F

J K T

"U" Dimension

D
Single

Junction Styles
Grounded
Common

Specify " U " Length In Inches 0 6 Example "U" is 6" = 06

Element Description
Duplex

Ungrounded
Common Isolated

G D F

U H

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

SPECIAL SENSOR ASSEMBLIES


Epoxy Potted RTD Assembly
Low temperature application

Model Code: Z3
Epoxy Potted RTD Element

1"

3 1/2"
Operating Temperature: -200 C to +250 C

Steps To Follow:

1.

2.

3.

4.

5.

6.

Model: 1.

Z3
Wire Description

S 24 Gage Stranded Stainless Steel Braid F 24 Gage Stranded Fiberglass Cable T 24 Gage Stranded Teflon Cable

4.

"B" Dimension

0 4 8 "B"= ________"
Leads Wire Length In Inches

5.

RTD Element Type


Ohms Class A Class B 2 1 1 x Pt100 4 3 2 x Pt100 1 x Pt1000 5 6 2 x Pt1000 8 7 Temperature Coefficient: 0.00385 Platinum element IEC 751

2.

Termination Type
0 1 2 3 4 5 3" Split Leads & 1/2" Bare Ends. 3" Slip Leads & Spade Lugs (2 & 3 Wire config. only) Standard Male Plug Standard Female Jack (2 & 3 Wire config. only) Mini Male Plug (2 & 3 Wire config. only) (2 & 3 Wire config. only) Mini Female Jack

6.

RTD Wire Connection


2 3 4 2 Wire Configuration 3 Wire Configuration 4 Wire Configuration
4 Wire Configuration
RED RED RED RED

3.

Accessories
N X C None Bx Connector Cable Clamp

2 Wire Configuration

3 Wire Configuration
RED RED

WHITE WHITE

WHITE

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

SPECIAL THERMOCOUPLE ASSEMBLIES


MAGNET MOUNT THERMOCOUPLE
Model Code: Z4
Epoxy Potting 275C Max. Stress Relief Spring
Operating Temperature: -200 C to +1000 C Max.

1.77"

0.55"

1.18"
A B C

2"
D

B
E F

3 1/2"

Model:

Z4
A
1 2

Magnet Pull
12 Ibs 24 lbs

"B" Dimension

Specify " B " Length In Inches 0 4 8 Example "B" is 48" = 048

B
1 2 3 4 5

Calibration

E
A B C D E

Cable Insulation Description

Standard Special Limits of Limits of Error Error

J K T E N

6 7 8 9 10

J K T E N

20 Gage, Stranded, Metal Braid 20 Gage, Stranded, Fiberglass .281" O.D. Flexible Armor Cable 20 Gage, Stranded, Teflon 20 Gage, Stranded, PVC

F C
Single Duplex

Termination
3" Split Leads & 1/2" bare ends. 3" Split Leads & Spade Lugs. Standard Male Plug (425 F) Standard Female Jack (425 F ) Mini Male Plug ( 425 F ) Mini Female Jack (425 F ) Hi Temp. Male Plug (800 F) Hi Temp. Female Jack (800 F)

Junction Styles
Ungrounded
Common Isolated

Element Grounded Description Common


G D

U F H

1 2 3 4 5 6 7 8

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

Stepped Thermowell
1/2" NPT Female Thread

ACCESSORIES P-SERIES THERMOWELLS


Straight Thermowell
1/2" NPT Female Thread

Tapered Thermowell
1/2" NPT Female Thread

Process Connection

Process Connection

Process Connection

U + 1.75"

U + 1.75"

U + 1.75"

U
0.25"

U
2.5"
0.25"

U
0.25"

Bore holes are 0.26" O.D.

0.5"

Bore holes are 0.26" O.D.

0.765"

Bore holes are 0.26" O.D.

0.625"

Model Code: P1
Model A

Model Code: P2
B

Model Code: P3
C

Thermowell Model
1 2 3 P1 P2 P3

A
A B C D E F G H

"U" Fractional

Dimension
1 5/8" 2 1/2" 4 1/2" 7 1/2" 10 1/2" 13 1/2" 16 1/2" 22 1/2"

B
1 2 3 4 5

Sheath Material
304 Stainless 316 Stainless Inconel 600 Carbon Steel Solid Teflon

C
A B C

Process Connection
1/2" NPT 3/4" NPT 1" NPT

For all other materials contact factory for availability.

For all other U lengths contact factory for availability.

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

ACCESSORIES
THERMOCOUPLE EXTENTION CABLES
( Step No. 2 )

Input Termination

Model Code: X1
Wire Insulation Cable Protection

( Step No. 8 )

Output Termination
NORDIC SENSORS

3 1/2"
Model:
1. 2. 3. 4.

B
5. 6. 7. 8. 9.

X1
1.
Calibration
J K T E N (+) Iron Vs. (-) Constantan (+) Ni.-Chromium Vs. (-) Ni.-Aluminum (+) Copper Vs. (-) Constantan (+) Ni.-Chromium Vs. (-) Constantan (+) Nicrosil Vs. (-) Nisil

6.

Wire Insulation Description


1 2 3 4 5 Fiberglass Insulation Jacket Teflon Insulation Jacket Teflon Jacket, Tin foil Sheild & Drain Wire P.V.C. Insulation Jacket P.V.C. Jacket, Tin foil Sheild & Drain Wire

2.

Input Termination Option


1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

7.

Wire Cable Protection


N None S Stanless Steel Overbraid F Flexible Armor Cable

3.

Input Accessories
A None B Bx Connector C Cable Clamp

8.

Output Termination Option


1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. Standard Male Plug Standard Female Jack Mini Male Plug Mini Female Jack

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

5.

Wire Gage Description


A B C D 24 Gage Stranded Conductors 24 Gage Solid Conductors 20 Gage Stranded Conductors 20 Gage Solid Conductors

9.

Output Accessories
A None B Bx Connector C Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

ACCESSORIES
RTD EXTENTION CABLES
( Step No. 2 )

Input Termination

Model Code: X2
Wire Insulation Cable Protection

( Step No. 8 )

Output Termination
NORDIC SENSORS

3 1/2"
Model:
1. 2. 3. 4.

B
5. 6. 7. 8. 9.

X2
1.
Number Of Conductors
A 2 Conductors B 3 Conductors C 4 Conductors

6.

Wire Insulation Description


1 2 3 4 5 Fiberglass Insulation Jacket Teflon Insulation Jacket Teflon Jacket, Tin foil Sheild & Drain Wire P.V.C. Insulation Jacket P.V.C. Jacket, Tin foil Sheild & Drain Wire

2.

Input Termination Option


1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. 2 & 3 Wire Cable, Only Standard Male Plug Standard Female Jack 2 & 3 Wire Cable, Only 2 & 3 Wire Cable, Only Mini Male Plug 2 & 3 Wire Cable, Only Mini Female Jack

7.

Wire Cable Protection


N None S Stanless Steel Overbraid F Flexible Armor Cable

3.

Input Accessories
A None B Bx Connector C Cable Clamp

8.

Output Termination Option


1 2 3 4 5 6 3" Split Leads & 1/2" Bare Ends. 3" Split Leads & No.10 Spade Lugs. 2 & 3 Wire Cable, Only Standard Male Plug Standard Female Jack 2 & 3 Wire Cable, Only 2 & 3 Wire Cable, Only Mini Male Plug 2 & 3 Wire Cable, Only Mini Female Jack

4.

"B" Dimension 0 4 8 "B"= ________"


Leads Wire Length In Inches

5.

Wire Gage Description


A 26 Gage Stranded Conductors B 24 Gage Stranded Conductors C 20 Gage Stranded Conductors

9.

Output Accessories
A None B Bx Connector C Cable Clamp

Nordic Sensors Ind. Inc. Tel: 1-888-667-3421 & Fax: 1-888-867-9986.

ACCESSORIES
STANDARD CONNECTORS

Temperature rating 425 F Max

MALE (2-PIN) PART #


LP - (__)

FEMALE (2-PIN) PART #


LJ - (__)

CALIBRATIONS
J, K, T, R, U, E, N

CALIBRATIONS
J, K, T, R, U, E, N

MALE (3-PIN) PART # CALIBRATIONS


LP3 - (__) J, K, T, R, U, E, N

FEMALE (3-PIN) PART #


LJ3 -(__)

CALIBRATIONS
J, K, T, R, U, E, N

HIGH TEMPERATURE
High temperature rating 800 F continuous (1000 F intermittent)

MALE (2-PIN) PART # CALIBRATIONS


HTLP - (__) J, K, T, R, U, E, N,

FEMALE (2-PIN) PART # CALIBRATIONS


HTLJ - (__) J, K, T, R, U, E, N,

MALE (3-PIN) PART # CALIBRATIONS


HTLP3 -(__) J, K, T, R, U, E, N,

FEMALE (3-PIN) PART # CALIBRATIONS


HTLJ3 -(__) J, K, T, R, U, E, N,

PANEL JACKS

Temperature rating 400 F (max) 2 - PIN 3 - PIN

PART #
H 30 - __

CALIBRATIONS
J, K, T, R, U, E, N

PART #
H 303 - __

CALIBRATIONS
J, K, T, R, U, E, N

CIRCULAR (2-PIN) PART #


H 32 - __

CALIBRATIONS
J, K, T, R, U, E, N

HIGH TEMPERATURE
High temperature rating 550 F (max)

STANDARD (2-PIN) PART #


HTH30 - _

CIRCULAR (2-PIN) PART #


HTH32 - _

CALIBRATIONS
J, K, T, R, U, E, N

CALIBRATIONS
J, K, T, R, U, E, N,

MINI MALE PLUG

Temperature rating 400 F

2-PIN PART #
MP -( _ )

3-PIN CALIBRATIONS
J, K, T, R, U, E, N,

PART #
MP3 -( _ )

CALIBRATIONS
J, K, T, R, U, E, N,

HIGH TEMPERATURE MINI PLUG


High temperature rating 550 F

2-PIN PART #
HTMP -( _ )

3-PIN CALIBRATIONS
J, K, T, R, U, E, N,

PART #
HTMP3 -( _ )

CALIBRATIONS
J, K, T, R, U, E, N,

MINI JACK ( FEMALE)

Temperature rating 400 F

2-PIN PART #
MJ -( _ )

3-PIN CALIBRATIONS
J, K, T, R, U, E, N,

PART #
MJ3 -( _ )

CALIBRATIONS
J, K, T, R, U, E, N,

HIGH TEMPERATURE MINI JACK


High temperature rating 550 F

2-PIN PART #
HTMJ - ( _ )

3-PIN CALIBRATIONS
J, K, T, R, U, E, N,

PART #
HTMJ3 - ( _ )

CALIBRATIONS
J, K, T, R, U, E, N,

STANDARD PANELS FOR OUTLET BOXES

No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

PART#
H510 H511 H512 H513 H514 H515 H516 H550 H551 H551-1 H552 H553 H554 H555 H555-16 H555-18 H556 (2 rows of 20) H557 (4 rows of 20)

# OF JACKS
0 1 2 3 4 5 6 5 6 6 8 10 12 20 16 18 40 80

SIZE
2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 2 3/4" x 4 1/2" 3 1/4" x 5 3/4" 3 1/4" x 5 3/4" 2 5/8" x 5 3/4" 3 1/4" x 7 1/4" 3 1/4" x 8 3/4" 3 1/4" x 10 1/4" 3 1/2" x 19" 3 1/2" x 19" 3 1/2" x 19" 5 1/4" x 19" 8 3/4" x 19"

BAYONET ADAPTORS

No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

PART #
H440-7-1-NI H440-7-3 H440-7-3-NI H440-7-BPT H441-0-3-16 H441-2-1-NI H441-3-1-NI H441-3-3 H441-3-3-16 H441-4-1-NI H441-6-1 H442-0-1-NI H442-2-1-NI H442-4-1-NI H443-0-1-NI H443-0-3 H443-4-1-NI H443-4-3-NI H444-0-1-NI H444-4-1 H445-0-1 H445-4-1

MATERIAL
Steel, Nickel PI. Steel, Zinc PI. Steel, Nickel PI. Steel, Blk. Ox Steel, Zinc PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Zinc PI. Steel, Zinc PI. Steel, Nickel PI. Steel, Zinc PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Zinc PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Nickel PI. Steel, Zinc PI. Steel, Zinc PI. Steel, Zinc PI.

LENGTH
7/8" 7/8" 7/8" 7/8" 1" 1 1/4" 1 3/8" 1 3/8" 1 3/8" 1 1/2" 1 3/4" 2" 2 1/4" 2 1/2" 3" 3" 3 1/2" 3 1/2" 4" 4 1/2" 5" 5 1/2"

THREADS
1/8 NPT 3/8 x 24 3/8 x 24 1/8 x 28 British 3/8 x 16 1/8 NPT 1/8 NPT 3/8 x 24 3/8 x 16 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT 3/8 x 24 1/8 NPT 3/8 x 24 1/8 NPT 1/8 NPT 1/8 NPT 1/8 NPT

STOCK METRIC ADAPTORS

PART #
EA121 EA1215 EA1275 EA141 EA1415 EA142 EA1615

SIZE & THREAD


M12 x 1 M12 x 1.5 M12 x 1.75 M14 x 1 M14 x 1.5 M14 x 2 M16 x 1.5

LENGTH
25 mm 25 mm 25 mm 30 mm 38 mm 30 MM 30 MM

* For Additional models please inquire

2-WIRE HEAD MOUNT ( RTD, T/C ) TRANSMITTER


FEATURE
Accuracy: RTD: 0.15%, T/C: 0.3% Wide selection of input / output range Dimension small Low output ripple Head Mount type High stability & low cost

TT

SPECIFICATION
Input Range
Type K 0 ~ 1200 Type J 0 ~ 1000 Type E 0 ~ 800 Type T -50 ~ 400 Pt100 -100 ~ 800

ADJUSTMENT
Output Range Load Resistance
Pt100 INPUT:
MODEL: TT-RTD RANGE: SERIAL NO: 24V DC

Input Impedance
1M ohm 1M ohm 1M ohm 1M ohm 10M ohm

THERMOCOUPLE INPUT:
MODEL: TTRANGE: SERIAL NO: 24V DC

2
ZERO

4 ~ 20 mA

( Vs-12 ) / 20mA (ohm)

SPAN

SPAN

ZERO: Zero Adjust Pot (Clockwise: o/p increase) SPAN: Span Adjust Pot (Clockwise: o/p increase)

Accuracy: Response time: Span adjustment:: Zero adjustment:: Output ripple: Power Supply: Open circuit protection: Operating temperature: Operating relative humidity: Temperature coefficient: Cold junction Storage temperature: Weight:

RTD ( Pt100 ): 0.15% of R.O. T/C ( K, J, E, T ): 0.3% of R.O. 300 msec. 10% of R.O. 5% of R.O. 0.3% of R.O. DC 16 ~ 36V Upscale > 22mA 0~60 20~95 %RH 100 PPM/ 2510, error0.5 -10~70 50g

DIMENSIONS

4 1.2 8.0 12.3 7.0 50.0 12.3 8.0 1.2

ZERO

(Unit: mm)

CONNECTION DIAGRAM
RTD Transmitter TT-RTD
A B b

T/C Transmitter
DC 24V Power Supply

TT-

DC 24V Power Supply

Meter, Recorder or A/I Module

Meter, Recorder or A/I Module

ORDER INFORMATION TT- Input Type Input Range


RTD THERMOCOPLE CODE P K J E T A n n B n C n n n n n D n n n n n E n n n n n F n n n n n G n n n n H n n n n I n n n n J n n K n O TEMPERATURE RANGE
-50 ~+100 -10 ~+40 0 ~ 50 0 ~ 100 0 ~ 200 0 ~ 400 0 ~ 500 0 ~ 600 0 ~ 800 0 ~ 1000 0 ~ 1200 Specify

D-11

NYLON BARRIER TERMINAL STRIPS


Made 0f the same glass-filled Nylon used in our thermocouple connectors (350 F - 400 F Max) Similar to Cinch type 141 or equivalent with 27/64" screw spacing ineach section, with 6-32 terminal screws Nuts for the terminal screws are pressed into the back of the terminal strips. There are no terminal lugs or connecting strips between the terminal screws in each section on the basic H221-XX and H222-XX barrier terminal strips.
Series H221 - Screws are not installed, but are supplied in a separate bag ready for installation of the terminal lugs. Series H222 - Screws are installed (there is no lug between them in each section). Series H223 - Has nickel plated copper lugs installed in each section. For non-thermocople applications. Series H224 - Has thermocouple compensating lugs installed, as specified.
Number of Terminals Length: Inches Mounting Centers: Inches Part Number Basic Strip Part No. w/Screws Installed Part No.w/ Nickel Part Number w/TC Plated Copper Lugs lugs (Calibration)

2 3 4 6 8 10 12 14 16 20

1 5/8 2 1/8 2 1/2 3 3/8 4 1/4 5 1/8 6 6 7/8 7 3/4 9 1/2 Terminal Lugs

1 5/16 1 3/4 2 1/5 3 1/16 3 15/16 4 13/16 5 11/16 6 9/16 7 7/16 9 3/16

H221-2 H221-3 H221-4 H221-6 H221-8 H221-10 H221-12 H221-14 H221-16 H221-20 Spade Lugs

H222-2 H222-3 H222-4 H222-6 H222-8 H222-10 H222-12 H222-14 H222-16 H222-20

H223-2 H223-3 H223-4 H223-6 H223-8 H223-10 H223-12 H223-14 H223-16 H223-20

H224-2-_____ H224-3-_____ H224-4-_____ H224-6-_____ H224-8-_____ H224-10-____ H224-12-____ H224-14-____ H224-16-____ H224-20-____ Ring Lugs

T/C Alloy Chromel Alumel Iron Constantan Copper Alloy II Nicrosil Nisil

Terminal Lug P/N H200-CH H200-AL H200-IR H200-CO H200-CP H200-11 H200-N+ H200-N-

Spade Lug P/N H210-CH H210-AL H210-IR H210-CO H210-CP H210-11 H210-N+ H210-N-

Ring Lug for #8 Stud P/N H230-CH H230-AL H230-IR H230-CO H230-CP H230-11

Ring Lug for #10 Stud P/N H231-CH H231-AL

H231-N+ H231-N-

Compensated Terminal Lugs to Fit Barrier Terminal Blocks Compensated Spade and Ring Lugs to Accept AWG 18 Wire and Smaller. All Lugs Alloy Marked. (Sold in bags of 100)

COMPRESSION FITTINGS

"Drilled-Thru" for Thermocouples Re-Adjustable Fittings use a Teflon ferrule Lava and Neoprene Ferrules Available - Inquire

PART# NCB 12 NCB 14 NCB 18 NCB 22 NCB 24 NCB 28 NCB 32 NCB 32-4.5mm NCB 34 NCB 38 NCB 38-4.5mm NCB 42 NCB 44 NCB 48 NCB 88 NCS 11 NCS 12 NCS 12T NCS 21 NCS 22 NCS 22T NCS 22-3mm NCS 24 NCS 24T NCS 32 NCS 32T NCS 34 NCS 34T NCS 42 NCS 42T NCS 42-6mm NCS 44 NCS 44T NCS 48 NCS 48T NCS 64 NCS 64T NCS 68 NCS 68T

BORE 1/16" 1/16" 1/16" 1/8" 1/8" 1/8" 3/16" 4.5mm 3/16" 3/16" 4.5mm 1/4" 1/4" 1/4" 1/2" 1/16" 1/16" 1/16" 1/8" 1/8" 1/8" 3mm 1/8" 1/8" 3/16" 3/16" 3/16" 3/16" 1/4" 1/4" 6mm 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8"

MATERIAL Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting Brass Compression Fitting S/S Compression Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting S/S Compression Fitting S/S Re-Adjustable Fitting

NPT 1/8 1/4 1/2 1/8 1/4 1/2 1/8 1/8 1/4 1/2 1/2 1/8 1/4 1/2 1/2 1/16 1/8 1/8 1/16 1/8 1/8 1/8 1/4 1/4 1/8 1/8 1/4 1/4 1/8 1/8 1/8 1/4 1/4 1/2 1/2 1/4 1/4 1/2 1/2

Nominal Weights and Dimensions


Conductor Size AWG (MM) 12 (2.05) 14 (1.63) 14F* (1.80) 16 (1.29) 16F* (1.47) 18 (1.02) 18F* (1.22) 20 (0.81) 20F* (0.97) 22 (0.64) 24 (0.51) 24F* (0.61) Insulation Thickness Inches (MM) .020 (.51) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) Jacket Thickness Inches (MM) .020 (.51) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38)

PVC Insulated 221F (105C)


Outer Diameter Inches (MM) .161 x .282 (4.1 x 7.2) .124 x .218 (3.1 x 5.5) .132 x .234 (3.4 x 5.9) .111 x .192 (2.8 x 4.9) .118 x .206 (3.0 x 5.2) .100 x .170 (2.5 x 4.3) .108 x .186 (2.7 x 4.7) .092 x .154 (2.3 x 3.9) .096 x .162 (2.4 x 4.1) .085 x .140 (2.2 x 3.6) .080 x .130 (2.0 x 3.3) .084 x .138 (2.1 x 3.5) Net Weight LB/MF (KG/KM) 57 (85) 34 (51) 38 (57) 24 (36) 26 (39) 17 (25) 18 (27) 14 (21) 15 (22) 8.1 (13) 7.1 (11) 7.6 (12)

* Denotes flexible 7-strand wire

Initial Calibration Tolerances Per ASTM E230 and MC96.1


Tolerance-Reference Junction 32F (0C) Standard Grade Special Grade Limits Limits F (C) whichever is Grade F (C) whichever greater Designat is greater ion +1.8 (1) or +0.75% +4 (2.2) or +0.75% +3.1(1.7) or +0.50% +4 (2.2) or +0.75% +1.8 (1) or +1.5% +3.1(1.7) or +1% +4 (2.2) or +2% +1.8 (1) +4 (2.2) +3.1(1.7) +4 (2.2) TT JJ EE KK or NN TT EE KK TTX JJX EEX KKX or NNX +0.9 (0.5) or 0.4% +2 (1.1) or 0.4% +1.8 (1) or 0.4% +2 (1.1) or 0.4% +0.9(0.5) or 0.8%** +1.8 (1) or 0.5%** ** +0.9 (0.5) +2 (1.1) +1.8 (1) +2 (1.1)

Thermocouple Type

Temperature Range F (C)

Grade Designation T J E K or N T E K TX JX EX KX or NX

Thermocouple Wire T 32 (0) to 700 (370) J 32 (0) to 1400 (760) E 32 (0) to 1600 (870) K or N 32 (0) to 2300 (1260) T* E* K* Extension Wire TX JX EX KX or NX -328 (-200) to 32 (0) -328 (-200) to 32 (0) -328 (-200) to 32 (0) 32 (0) to 212 (100) 32 (0) to 400 (200) 32 (0) to 400 (200) 32 (0) to 400 (200)

Compensating Extension Wire RX or SX 32 (0) to 400 (200) RX or SX +9 (5) BX 32 (0) to 212 (100) BX*** +7.6 (4.2) BX 32 (0) to 400 (200) BX ALLOY*** +6.7(3.7) Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet tolerances below 0C (32F), the purchase order must so state. Special selection of material is required. ** Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier. *** Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (112F). Above 100C (112F), PCLW30-6 alloy should be used as the positive extension wire.

Nominal Weights and Dimensions


Conductor Size AWG (MM) 12 (2.05) 14 (1.63) 14F* (1.80) 16 (1.29) 16F* (1.47) 18 (1.02) 18F* (1.22) 20 (0.81) 20F* (0.97) 22 (0.64) 24 (0.51) 24F* (0.61) Insulation Thickness Inches (MM) .020 (.51) .020 (.51) .020 (.51) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) .015 (.38) Jacket Thickness Inches (MM) .025 (.64) .025 (.64) .025 (.64) .020 (.51) .020 (.51) .020 (.51) .020 (.51) .020 (.51) .020 (.51) .020 (.51) .020 (.51) .020 (.51)

Shielded PVC Insulated 221F (105C)


Outer Diameter Inches (MM) .308 (7.8) .274 (7.0) .290 (7.4) .218 (5.5) .232 (5.9) .196 (5.0) .208 (5.3) .180 (4.6) .188 (4.8) .166 (4.2) .156 (4.0) .164 (4.1) Net Weight LB/MF (KG/KM) 77 (115) 54 (80) 60 (89) 35 (52) 38 (57) 25 (37) 27 (40) 18 (27) 20 (30) 16 (24) 12 (18) 13 (19)

* Denotes flexible 7-strand wire

Initial Calibration Tolerances Per ASTM E230 and MC96.1


Tolerance-Reference Junction 32F (0C) Standard Grade Special Grade Limits Limits F (C) whichever is Grade F (C) whichever greater Designat is greater ion +1.8 (1) or +0.75% +4 (2.2) or +0.75% +3.1(1.7) or +0.50% +4 (2.2) or +0.75% +1.8 (1) or +1.5% +3.1(1.7) or +1% +4 (2.2) or +2% +1.8 (1) +4 (2.2) +3.1(1.7) +4 (2.2) +9 (5) +7.6 (4.2) +6.7(3.7) TT JJ EE KK or NN TT EE KK TTX JJX EEX KKX or NNX +0.9 (0.5) or 0.4% +2 (1.1) or 0.4% +1.8 (1) or 0.4% +2 (1.1) or 0.4% +0.9(0.5) or 0.8%** +1.8 (1) or 0.5%** ** +0.9 (0.5) +2 (1.1) +1.8 (1) +2 (1.1)

Thermocouple Type

Temperature Range F (C)

Grade Designation T J E K or N T E K TX JX EX KX or NX RX or SX BX*** BX ALLOY***

Thermocouple Wire T 32 (0) to 700 (370) J 32 (0) to 1400 (760) E 32 (0) to 1600 (870) K or N T* E* K* Extension Wire TX JX EX KX or NX 32 (0) to 2300 (1260) -328 (-200) to 32 (0) -328 (-200) to 32 (0) -328 (-200) to 32 (0) 32 (0) to 212 (100) 32 (0) to 400 (200) 32 (0) to 400 (200) 32 (0) to 400 (200)

Compensating Extension Wire RX or SX 32 (0) to 400 (200) BX 32 (0) to 212 (100) BX 32 (0) to 400 (200)

Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet tolerances below 0C (32F), the purchase order must so state. Special selection of material is required. ** Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier. *** Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (112F). Above 100C (112F), PCLW30-6 alloy should be used as the positive extension wire.

Nominal Weights and Dimensions


Conductor Size AWG (MM) 14 (1.63) 16 (1.29) 16F* (1.47) 18 (1.02) 20 (0.81) 20F* (0.97) 22 (0.64) 24 (0.51) 24F* (0.61) 26 (0.41) 28 (0.32) 30 (0.25) Insulation Thickness Inches (MM) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) .008 (.20) Jacket Thickness Inches (MM) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .010 (.25)

PFA Insulated 500F (260C)


Outer Diameter Inches (MM) .104 x .188 (2.6 x 4.8) .087 x .154 (2.2 x 3.9) .094 x .168 (2.4 x 4.3) .076 x .132 (1.9 x 3.4) .068 x .116 (1.7 x 2.9) .072 x .124 (1.8 x 3.1) .061 x .102 (1.5 x 2.6) .056 x .092 (1.4 x 2.3) .060 x .100 (1.6 x 2.7) .052 x .084 (1.3 x 2.1) .049 x .078 (1.2 x 2.0) .046 x .072 (1.2 x 1.8) Net Weight LB/MF (KG/KM) 34 (51) 22 (33) 24 (36) 15 (22) 11 (16) 12 (18) 7.6 (11) 5.7 (8.5) 6.2 (9.2) 4.4 (6.5) 3.7 (5.5) 3.0 (4.5)

* Denotes flexible 7-strand wire

Initial Calibration Tolerances Per ASTM E230 and MC96.1


Tolerance-Reference Junction 32F (0C) Standard Grade Special Grade Limits Limits F (C) whichever is Grade F (C) whichever greater Designat is greater ion +1.8 (1) or +0.75% +4 (2.2) or +0.75% +3.1(1.7) or +0.50% +4 (2.2) or +0.75% +1.8 (1) or +1.5% +3.1(1.7) or +1% +4 (2.2) or +2% +1.8 (1) +4 (2.2) +3.1(1.7) +4 (2.2) +9 (5) +7.6 (4.2) +6.7(3.7) TT JJ EE KK or NN TT EE KK TTX JJX EEX KKX or NNX +0.9 (0.5) or 0.4% +2 (1.1) or 0.4% +1.8 (1) or 0.4% +2 (1.1) or 0.4% +0.9(0.5) or 0.8%** +1.8 (1) or 0.5%** ** +0.9 (0.5) +2 (1.1) +1.8 (1) +2 (1.1)

Thermocouple Type

Temperature Range F (C)

Grade Designation T J E K or N T E K TX JX EX KX or NX RX or SX BX*** BX ALLOY***

Thermocouple Wire T 32 (0) to 700 (370) J 32 (0) to 1400 (760) E 32 (0) to 1600 (870) K or N 32 (0) to 2300 (1260) T* E* K* Extension Wire TX JX EX KX or NX -328 (-200) to 32 (0) -328 (-200) to 32 (0) -328 (-200) to 32 (0) 32 (0) to 212 (100) 32 (0) to 400 (200) 32 (0) to 400 (200) 32 (0) to 400 (200)

Compensating Extension Wire RX or SX 32 (0) to 400 (200) BX 32 (0) to 212 (100) BX 32 (0) to 400 (200)

Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet tolerances below 0C (32F), the purchase order must so state. Special selection of material is required. ** Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier. *** Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (112F). Above 100C (112F), PCLW30-6 alloy should be used as the positive extension wire.

Nominal Weights and Dimensions


Conductor Size AWG (MM) 14 (1.63) 16 (1.29) 16F* (1.47) 18 (1.02) 20 (0.81) 20F* (0.97) 22 (0.64) 24 (0.51) 24F* (0.61) 26 (0.41) 28 (0.32) 30 (0.25) Insulation Thickness Inches (MM) .007 (.18) .007 (.18) .007 (.18) .007 (.18) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .004 (.11) .004 (.11) .004 (.11) Jacket Thickness Inches (MM) .010 (.25) .010 (.25) .010 (.25) .010 (.25) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .006 (.15) .006 (.15)

Fiberglass Insulated 950F (510C)


Outer Diameter Inches (MM) .100 x .180 (2.5 x 4.6) .085 x .150 (2.2 x 3.8) .094 x .168 (2.4 x 4.3) .070 x .124 (1.8 x 3.2) .056 x .100 (1.4 x 2.5) .060 x .108 (1.5 x 2.7) .049 x .086 (1.2 x 2.2) .040 x .068 (1.0 x 1.7) .048 x .084 (1.2 x 2.1) .036 x .060 (0.9 x 1.5) .033 x .054 (0.8 x 1.4) .030 x .048 (0.8 x 1.2) Net Weight LB/MF (KG/KM) 29 (43) 20 (30) 22 (33) 13 (19) 7.7 (11) 8.3 (12) 5.4 (8.0) 3.2 (4.8) 3.4 (5.1) 2.2 (3.3) 1.7 (2.5) 1.3 (1.9)

* Denotes flexible 7-strand wire

Initial Calibration Tolerances Per ASTM E230 and MC96.1


Tolerance-Reference Junction 32F (0C) Standard Grade Special Grade Limits Limits F (C) whichever is Grade F (C) whichever greater Designat is greater ion +1.8 (1) or +0.75% +4 (2.2) or +0.75% +3.1(1.7) or +0.50% +4 (2.2) or +0.75% +1.8 (1) or +1.5% +3.1(1.7) or +1% +4 (2.2) or +2% +1.8 (1) +4 (2.2) +3.1(1.7) +4 (2.2) +9 (5) +7.6 (4.2) +6.7(3.7) TT JJ EE KK or NN TT EE KK TTX JJX EEX KKX or NNX +0.9 (0.5) or 0.4% +2 (1.1) or 0.4% +1.8 (1) or 0.4% +2 (1.1) or 0.4% +0.9(0.5) or 0.8%** +1.8 (1) or 0.5%** ** +0.9 (0.5) +2 (1.1) +1.8 (1) +2 (1.1)

Thermocouple Type

Temperature Range F (C)

Grade Designation T J E K or N T E K TX JX EX KX or NX RX or SX BX*** BX ALLOY***

Thermocouple Wire T 32 (0) to 700 (370) J 32 (0) to 1400 (760) E 32 (0) to 1600 (870) K or N 32 (0) to 2300 (1260) T* E* K* Extension Wire TX JX EX KX or NX -328 (-200) to 32 (0) -328 (-200) to 32 (0) -328 (-200) to 32 (0) 32 (0) to 212 (100) 32 (0) to 400 (200) 32 (0) to 400 (200) 32 (0) to 400 (200)

Compensating Extension Wire RX or SX 32 (0) to 400 (200) BX 32 (0) to 212 (100) BX 32 (0) to 400 (200)

Thermocouple material is normally supplied to meet tolerances above 0C (32F). If material is required to meet tolerances below 0C (32F), the purchase order must so state. Special selection of material is required. ** Suggested initial calibration tolerance. Requirements should be discussed between purchaser and supplier. *** Copper vs. copper can be used as an extension for Type B thermocouples if the transition is below 100C (112F). Above 100C (112F), PCLW30-6 alloy should be used as the positive extension wire.

Color Codes

TEMPERATURE AND METRIC CONVERSION DATA


F..C
140..60.00 141..60.55 142..61.11 143..61.66 144..62.22 145..62.78 146.63.33 147..63.88 148..64.44 149..65.00 150..65.56 151..66.11 152.66.66 153..67.22 154..67.77 155..68.33 156..68.88 157..69.44 158..70.00 159..70.55

Temperature Conversion Data F..C F..C


160..71.11 161..71.66 162..72.22 163..72.77 164..73.33 165..73.89 166..74.44 167..75.00 168..75.55 169..76.11 170..76.67 171..77.22 172..77.77 173..78.33 174..78.88 175..79.44 176..80.00 177..80.55 178..81.11 179..81.66 180..82.22 181..82.77 182..83.33 183..83.88 184..84.44 185..85.00 186..85.55 187..86.11 188..86.66 189..87.22 190..87.78 191..88.33 192..88.88 193..89.44 194..90.00 195..90.55 196..91.11 197..91.66 198..92.22 199..92.77

F..C
200..93.33 205..96.11 210..98.89 215....101.67 220104.44 225....107.22 230....110.00 235....112.78 240........115.56 245....118.33 250....121.11 255....123.89 260....126.67 265....129.44 270....132.22 275....135.00 280....137.78 285....140.55 290....143.33 295146.11

F..C
300..148.89 305..151.67 310..154.44 315..157.22 320..160.00 325..162.78 330..165.56 335..168.33 340..171.11 345..173.89 350..176.67 355..179.44 360..182.22 365..185.00 370..187.78 375..190.55 380..193.33 385..196.11 390..198.89 395..201.67

Length
Inch x 25.4 = Millimeters Millimeters x 0.03937 = Inches Feet x 0.3048 = Meters Meters x 3.281 = Feet

Metric Conversion Factors Area


Square Inch x 6.452 = Square Centimeter Square Centimeter x 0.1550 = Square Inch Square Foot x 0.0929 = Square Meter Square Meter x 10.76 = Square Foot

Mass
Ounce x 28.35 = Gram Gram x 0.03527 = Ounce Pound x 0.4536 = Kilogram Kilogram x 2.205 = Pound

Volume
Cubic Inch x 16.39 = Cubic Centimeter Cubic Centimeter x 0.06102 = Cubic Inch Cubic Foot x 0.02832 = Cubic Meter Cubic meter x 35.31 = Cubic Foot

Fractions to decimals to Millimeters Conversion Chart Inches


Fraction Decimal mm

Inches
Fraction Decimal

mm

Inches
Fraction Decimal

mm

Inches
Fraction Decimal

mm

1/64 1/32 3/64 1/16 5/64 3/32 7/64 1/8 9/64 5/32 11/64 3/16 13/64 7/32 15/64 1/4

0.0156 0.0312 0.0468 0.0625 0.0781 0.0937 0.1093 0.1250 0.1406 0.1562 0.1718 0.1875 0.2031 0.2187 0.2343 0.2500

0.3969 0.7938 1.1906 1.5875 1.9844 2.3812 2.7781 3.1750 3.5719 3.9688 4.3656 4.7625 5.1594 5.5562 5.9531 6.3500

17/64 9/32 19/64 5/16 21/64 11/32 23/64 3/8 25/64 13/32 27/64 7/16 29/64 5/32 31/64 1/2

0.2656 0.2812 0.2968 0.3125 0.3281 0.3437 0.3593 0.3750 0.3906 0.4062 0.4218 0.4375 0.4531 0.4687 0.4843 0.5000

6.7469 7.1438 7.5406 7.9375 8.3344 8.7312 9.1281 9.5250 9.9219 10.3188 10.7156 11.1125 11.5094 11.9062 12.3031 12.7000

33/64 17/32 35/64 9/16 37/64 19/32 39/64 5/8 41/64 21/32 43/64 11/16 45/64 23/32 47/64 3/4

0.5156 0.5312 0.5468 0.5625 0.5781 0.5937 0.6093 0.6250 0.6406 0.6562 0.6718 0.6875 0.7031 0.7187 0.7343 0.7500

13.0969 13.4938 13.8906 14.2875 14.6844 15.0812 15.4781 15.8750 16.2719 16.6688 17.0656 17.4625 17.8594 18.2562 18.6531 19.0500

49/64 25/32 51/64 13/16 53/64 27/32 55/64 7/8 57/64 29/32 59/64 15/16 61/64 31/32 63/64 1

0.7656 0.7812 0.7968 0.8125 0.8281 0.8437 0.8593 0.8750 0.8906 0.9062 0.9218 0.9375 0.9531 0.9687 0.9843 1.0000

19.4469 19.8437 20.2406 20.6375 21.0344 21.4312 21.8281 22.2250 22.6219 23.0188 23.4156 23.8125 24.2094 24.6062 25.0031 25.4000