Residual Current Monitors Residual current monitoring in electrical installations


BETA Low-Voltage Circuit Protection

Plant safety and operating safety are becoming increasingly important along side the protection of personnel. Shutdowns due to the unexpected tripping of protective devices cause high costs. It is possible however to detect residual currents in the electrical installation before the protective device responds. Detect faults in time Residual current monitors (RCM) monitor residual currents in electrical installations and issue a signal when these currents exceed a defined value. Plant operators are thus able to detect and remedy faults before the plant is shut down unexpectedly.
7

Highlights
7

Higher plant availability and operating safety through permanent monitoring of residual currents Adjustable limit values for residual current and response time enable timely detection and signaling plant shutdowns are often avoidable Additional fire protection can be implemented using the monitoring system

Devices for every application The current transformers are available in various sizes, the RCMs can be used optionally for signaling and/or switching.
7

Answers for infrastructure.

Siemens AG 2009

Monitoring of Electrical Values


5SV8 Residual Current Monitors
Overview Unwanted circuit disconnections can be avoided by timely detection and correctly initiated actions. A residual current monitor (RCM) is designed to monitor an electrical installation for residual current and to issue a signal when the residual current exceeds a set value. RCMs are used primarily in plants where a fault should result in a signal but not in disconnection. Plant operators are thus able to detect faults and eliminate their causes before the protective devices disconnect the installation. As the result, plant safety and operating safety are increased and costs decreased. The current transformer detects all conductors required to conduct the current, i.e. also the neutral conductor where applicable. In a fault-free system, the magnetizing effects of the conductors through which current is flowing cancel each other out for the current transformer, i.e. the sum of all currents is zero. If a residual current is flowing due to an insulation fault, a residual magnetic field is left in the core of the transformer and produces a voltage. This voltage is evaluated using the electronics of the RCM. The switched contact can be used e.g. to operate an acoustic/optical signaling device, a higher-level control system or a circuit breaker. Technical specifications
RCM analog, type A Standards Rated operational voltage Ue Frequency Rated residual current n Response time tv Relay contacts Rated voltage Rated current Current transformer Test/Reset External tripping operation/external reset Mounting width Degree of protection Contacts Front Operating temperature
1)

Residual current I

100 % I n Disconnection

50 % I Alarm

Time t

Time characteristic of the rated residual current n

RCM digital, type A

RCM digital, 4 channels, type A

EN 62020, IEC 62020 V AC Hz A s 230 50/60 0.03 ... 5 0.02 ... 5 1 alarm V AC A mm 230 6 20 ... 210 Yes/Yes --/Yes MW 2 IP20 IP41 C -10 ... +50 Yes/Yes 3 Yes/Yes 3 0.03 ... 30 0.02 ... 10, INS, SEL1) 1 alarm, 1 tripping operation 230 6 0.03 ... 30 0.02 ... 10, INS, SEL1) 1 alarm, 1 tripping operation 230 6

INS: Instantaneous, SEL: selective.

Monitoring of Electrical Values

I2_16044

Siemens AG 2009

Selection and ordering data (Dated 08/2009)


Rated operational voltage Ue V AC 230, 50/60 Hz Rated residual current In A 0.03 ... 5 Response time Mounting DT width tv s 0.02 ... 5 TE 2 B 5SV8 000-6KK Unit(s) Unit(s) 1 1 027 Order No. PU PS*/ P. unit PG Weight per PU approx. kg 0.163

RCM analog, type A

RCM digital, type A 230, 50/60 Hz 0.03 ... 30 0.02 ... 10, INS, SEL 3 B 5SV8 001-6KK 1 1 027 0.236

RCM digital, 4 channels, type A 230, 50/60 Hz 0.03 ... 30 0.02 ... 10, INS, SEL 3 B 5SV8 200-6KK 1 1 027 0.236

Internal diameter DT

Order No.

PU

PS*/ P. unit

PG

Weight per PU approx. kg

mm Current transformers Including holder for standard mounting rail 20 30 B B 5SV8 700-0KK 5SV8 701-0KK

Unit(s) Unit(s) 1 1 1 1 027 027

0.076 0.095

Including holder for wall mounting1)

35 70 105 140 210

B B B B B

5SV8 702-0KK 5SV8 703-0KK 5SV8 704-0KK 5SV8 705-0KK 5SV8 706-0KK

1 1 1 1 1

1 1 1 1 1

027 027 027 027 027

0.181 0.274 0.545 1.222 2.040

Including holder for wall mounting

Holders for standard mounting rails Suitable for current transformer with internal diameter of 20 mm, 30 mm, 35 mm, 70 mm and 105 mm

5SV8 900-1KK

027

0.004

1)

Mounting on standard mounting rail with optional holder for standard mounting rail also possible.

* You can order this quantity or a multiple thereof.

Monitoring of Electrical Values

Siemens AG 2009

Dimensional drawings Residual current monitor


I2_16028

I2_116027

36 6

44 68

45 67 85

54 6

44 68

RCM analog, 5SV8 000-6KK

RCM digital, 5SV8 001-6KK, 5SV8 200-6KK

Current transformer
32
I2_116029

32

I2_16030

24

Current transformer, 5SV8 700-0KK

Current transformer, 5SV8 701-0KK

A 33 F
I2_16031

Type

DiA mension 100 130 170 230 299

30
D

20 46

60

59

70

30

45 67 85
E

5SV8 702-0KK 5SV8 703-0KK

79 110 146 196 284

26 32 38 49 69

49 66 94 123 161

35 70 105 140 210

35 52 72 97 141

43 57 73 98 142

5SV8 704-0KK 5SV8 705-0KK 5SV8 706-0KK

6,5

Current transformers, 5SV8 702-0KK, 5SV8 703-0KK, 5SV8 704-0KK, 5SV8 705-0KK, 5SV8 706-0KK

Monitoring of Electrical Values

46

Siemens AG 2009

Schematics Residual current monitor

5 L

7 8

7 8

N S1 S2

L1 L2 L3 N

N S1 S2

L1 L2 L3 N

NO C NC 1 2 3 4

ST

NO C NC 1 2 3 4

ST

1S1 1S2

1S1 1S2

1S1 1S2 2S12S2

RCM analog, 5SV8 000-6KK, shunt trip (ST)

I202_16032a

RCM analog, 5SV8 000-6KK, shunt trip (ST), self-acknowledging

5 L

7 8

5 L

7 8

N S1 S2

N S1 S2

L1 L2 L3 N

L1 L2 L3 N

NO C NC 1 2 3 4

UR

NO C NC 1 2 3 4

UR

1S1 1S2

1S1 1S2

I202_16034a

RCM analog, 5SV8 000-6KK, undervoltage release (UR)

I202_16033a

RCM analog, 5SV8 000-6KK, undervoltage release (UR), self-acknowledging

ST = shunt trip UR = undervoltage release

Monitoring of Electrical Values

I202_16035a

1S1 1S2 2S1 2S2 1S1 1S2 2S1 2S2

1S1 1S2 2S1 2S2

Siemens AG 2009

L1 L2 L3 N

L1 L2 L3 N

T ST

T ST

10 11 12 13 14 15 C2 Reset Test C1

1S1 1S2

10 11 12 13 14 15 C2 Reset Test C1
I202_16041a

1S1 1S2

1S1 1S2 2S1 2S2

1S1 1S2 2S1 2S2

S/R

1 2 3 4 5 6 7 89

S/R

1 2 3 4 5 6 7 89

RCM digital, 5SV8 001-6KK, shunt trip (ST)

RCM digital, 5SV8 001-6KK, shunt trip (ST), self-acknowledging

L1 L2 L3 N

T UR

10 11 12 13 14 15 C2 Reset Test C1

1S1 1S2

S/R

1 2 3 4 5 6 7 89

RCM digital, 5SV8 001-6KK, undervoltage release (UR) ST = shunt trip UR = undervoltage release

Monitoring of Electrical Values

I202_16043a

I202_16042a

1S1 1S2 2S1 2S2

Siemens AG 2009

LN 230 V AC
L1L2 L3N 1S1 1S2

L1L2 L3N

L N S/R

T1
10 11 12 13 14 15

1S1 1S2

T2
Reset Test
I202_16040a

10 11 12 13 14 15 L N C1 Reset C Test C3 C4 1S1 1S2 C2 L1L2 L3N

1 2 3 4 5 6 7 89

1 2 3 4 5 6 7 89 L1L2 L3N

T4
1S2 1S2 1S2 1S2 1S1 1S1 1S1 1S1

T4
T3
I202_16036a

T3

T2

T1

RCM digital, 4 channels, 5SV8 200-6KK, shunt trip (ST) ST = shunt trip

1S1 1S2

RCM digital, 4 channels, 5SV8 200-6KK S/R = set/reset

Monitoring of Electrical Values

Siemens AG 2009

More information Switching positions RCM digital, type A, 5SV8 001-6KK:


Alarm Setting Without power supply "Standard" Trip "Standard" Alarm "+" Trip "+"

4
With power supply

5 6 5 6 5 6 5 6

15

14 13 14 13 14 13 14 13

5 6 5 6 5 6 5 6

15

14 13 14 13 14 13 14 13

4
Over limit

15

15

4
CT disconnection

15

15

15

15

RCM digital, 4 channels, type A, 5SV8 200-6KK:


Alarm Setting Without power supply "Standard" Trip "Standard" Trip "+"

10

C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8

C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9

C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8 C1: 14 C2: 14 C3: 8 C4: 8

C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9 C1: 13 C2: 15 C3: 7 C4: 9

With power supply

10

Over limit

10

CT disconnection

10

Siemens AG Industry Sector Building Technologies Division Electrical Installation Technology Postfach 10 09 53 93009 REGENSBURG GERMANY www.siemens.com/beta

Subject to change without notice PDF only: (E10003-E38-9T-B2211-7600) PI 0809 En

Siemens AG 2009

The information provided in this brochure contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be registered trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes may violate the rights of the owner.

You might also like