Data sheet LA 11TAS Air-to-water heat pump

Order reference: LA 11TAS Max. flow temperature for heating: 58 C Casing colour: white aluminium Air-to-water heat pumps for outdoor installation with external temperature controlled WPM 2006 plus heat pump manager. Sound-optimised through the use of low-noise "owl's wings" ventilator blades; Energy-efficient defrosting by reverse circulation. High coefficients of performance due to compliance with EN 255 for larger volume flows on the heat consumption side. Observe the minimum clearances for installation close to walls. Universal design with optional DHW preparation and the option of flexible expansion for: - Bivalent or bivalent-renewable operating mode - Distribution systems with unmixed and mixed heating circuits Integrated flow sensor and soft starter, return flow sensor and external temperature sensor included in the scope of supply. Electric cable EVL ... to connect the heat pump and heat pump manager, must be ordered separately.

Technical data LA 11TAS

Dimplex Air-to-water heat pump (Low temperature)


Order reference
Casing colour Max. flow temperature for heating Temperature operating limits for air Heat output / COP at A-7/W35 Heat output / COP at A+2/W35 Heat output / COP at A+7/W35 Heat output / COP at A+10/W35 Sound pressure level at a distance of 10 m (air outlet side) Sound power level Refrigerant R404A Flow rate (heat source) Heating water flow rate with an int. pressure differential of Dimensions (W x D x H) Weight (incl. packing) Connection voltage Starting current with soft starter Fuse protection Type of defrosting Connection heating

LA 11TAS
white aluminium 58 C -25 C to 35 C 7,30 / 2,90 8,60 / 3,50 10,20 / 3,90 11,30 / 4,60 31 59 2,50 2500 1,30 / 4100 1050 x 852 x 1340 193 3/PE ~400 V, 50 Hz 15 13 Reverse circulation 1

kW/kW/kW/kW/dB (A) dB (A) kg m/h m/h / Pa mm kg A A

Heat output and COP according to EN 255 at A2/W35 (A2 = air intake temperature +2 C, W35 = heating water outlet temperature +35 C) Please note that additional space is required for pipe connections, operation and maintenance.

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 1/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

System accessories LA 11TAS


Description
Heat pumps
Air-to-water heat pump 10 m control line 20m control line 30m control line 40 m control line DN 25 double-sphere rubber expansion joint DN 25 dirt trap Air-to-water heat pump connection kit LA 11TAS EVL 996-1 EVL 997-1 EVL 998-1 EVL 999-1 KOMP 25 SMF 25 VSF 25 AS 976 PSW 100 PSW 200 PSW 500 KPV 25 DDV 25 UP 60 UP 80 WWM 25 UPE 60 UPE 70-25 VTB 25 MMH 25 MMB 25 HVL 25-50 HVL 25-75 HVL 25-100 HVL 25-150 HVL 32-150 HVL 32-200 HVL 32-250 VSE 32-50 VSE 32-100 VSE 32-150 VSE 32-200 VSE 32-300 SRX 080M SRX 120M SRX 140M SRX 180M HL 11C HL 16C HL 26C HL 36C HCT 300 HDLR 450 WWSP 332 WWSP 880 WWSP 442E WWSP 432 SOL HWK 332 PWS 332 CTHK 630 CTHK 631 CTHK 632 CTHK 633 CTHK 634 362570 321990 322000 322010 359120 362050 362130 361790 322180 351090 339830 339210 346590 358390 340300 340310 346600 358870 362790 339870 348640 348880 358650 358660 358670 358880 358680 358690 358700 362520 362530 362540 362550 362560 359080 359090 359100 359110 351730 351740 351750 351760 351210 337450 346610 337880 353370 361080 362360 348620 363610 336180 335910 322140 322150 1 1

Order ref.

Article number

Sample item

Item

Price

Hydraulic accessories
1" connecting hose* Floor-mounted buffer tank (100 l)* Floor-mounted buffer tank (200l)* Universal buffer tank (500 l)* Compact manifold with overflow valve* Dual differential pressureless manifold Circulating pump for heating water Circulating pump for heating water Hot water module / unmixed heating circuit module Electronically regulated circulating pump for heating water Electronically regulated wet running pump (0-10 V) with coupling relay Manifold bar Mixed heating circuit module with temperature sensor Mixer module for bivalent systems District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* District heating lines with ready-to-use 90 bend* Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe Ready-for-use DN 32 stainless steel Wellflex pipe

1 1 1 1

Heating accessories
Fan convector for heating 800 W Fan convector for heating 1200 W Fan convector for heating 1400 W Fan convector for heating 1800 W Fan convector for heating/cooling Fan convector for heating/cooling Fan convector for heating/cooling Fan convector for heating/cooling 3 kW pipe heater Immersion heater pipe assembly*

DHW preparation accessories


Hot water cylinder (300l) with temperature sensor* Hot water cylinder (400l) with temperature sensor* Design hot water cylinder with sheet metal coverings and temperature sensor* 400l solar cylinder for heat pump Hydro tower without regulation Combination tank for heating and DHW preparation CTHK 630 immersion heater, 4.5 kW, ~230 V CTHK 631 immersion heater, 2.0 kW CTHK 632 immersion heater, 2.9 kW CTHK 633 immersion heater, 4.5 kW CTHK 634 immersion heater, 6.0 kW

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 2/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

System accessories LA 11TAS


Description
Immersion heater 7.5 kW; ~400 V Flange heater for domestic hot water Flange heater for domestic hot water FLH 25M flange heater Safety valve combination Combo tank for heating and domestic hot water preparation with central flow* Combo tank for heating and domestic hot water preparation with central flow* Manifold bar Hot water module / unmixed heating circuit module Pump unit DN 25 for direct connection of the hot water cylinder Circulating pump for heating water

Order ref.
CTHK 635 FLH 60 FLHU 70 FLH 25M SVK 852 PWD 750 PWD 900 VTB 25 WWM 25 WPG 25 UP 60 NWPM EWPM LWPM 410 RBG WPM AP PGD FG 3115 Norm NTC-2 FA 550 KRRV 003 SOLPU 1

Article number
322160 338060 338070 349430 326660 349100 362860 339870 346600 356030 340300 356960 356970 339410 339700 356570 336620 353400 338550 322070 356230

Sample item

Item

Price

1 1

Control accessories
Extension for an Ethernet network connection Extension for a KNX/EIB bus connection Extension for a Modbus connection Swimming pool / remote fault indicator relay module Remote control for WPM 2006/2007/EconPlus/R* External temperature sensor with casing Temperature sensor Strap-on sensor Thermostat for heating and domestic hot water

Solar thermal systems accessories


Solar station * Other specific accessories available / required Important information: The combination of the components and the quantities indicated represent a non-binding sample system, which needs to be tested and individually adapted as required. Pump dimensioning must be reviewed according to the pressure loss of the system and the minimum heating water flow rate of the heat pump.

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 3/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater
Note: The given hydraulic integration schematic is a schematic representation of the key components and serves as an aid for planning your customized system. The current status is available at all times under www.dimplex.de/nc/en/professional/onli ne-planner/hydraulic-integrations.html. It does not contain all the required safety devices, the components needed to maintain constant pressure, or any other additional valves which may be required for maintenance and service work as stipulated by EN 12828. The heat pump manager settings and any external regulation system which may be connected must be adapted to the present integration diagram. Software updates may be required!

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 4/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Integration Diagram: 10211020 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater
System description:
Air-to-water heat pumps with defrosting by reverse circulation extract the energy required for defrosting from the heating system. In the case of air-to-water heat pumps, a buffer tank connected in series, into which the immersion heater is screwed, must be installed in the flow in mono energy systems to ensure defrosting. A dirt trap with a mesh size of between 0.6mm and 0.8mm is to be installed in order to protect the plate heat exchanger from larger dirt deposits. Clean the filter sieve of the dirt trap one day after start-up. These intervals can be extended as soon as no more impurities are detected. When the level of impurities is significantly high (e.g. due to corrosion found in the building), it is recommended that a sludge trap be installed in order to minimise the need for regular cleaning. A permanent corrosion process, caused by the entry of oxygen into the system, is characteristic of heating systems featuring open diffusion. This is best alleviated using an electrophysical anti-corrosion system. Condensate which forms during defrosting must be drained off without risk of frost. Acoustic emissions must be taken into account, and a free air circuit provided for, when the installation location is being selected. Heat pumps without weather-proof protective covers in particular need to be installed outdoors in such a manner that the air outlet is not positioned against the main wind direction. A buffer tank connected in series is recommended for heat pump heating systems, to ensure the minimum heat pump runtime of 6 minutes for all operating statuses.

Presettings:
Pre-configuration
Operating mode Heating circuit 1 Heating circuit 2 DHW preparation DHW preparation request by Domestic hot water preparation flange heater Swimming pool water preparation

Setting
Mono energy Yes No Yes Sensor Yes No

The heat pump supplies a large part of the required heat output. An electric heating element (immersion heater) supplements the heat pump on days when the external temperature lies below the bivalence point. In mono energy systems, the contactor for the immersion heater (E10.1) must be set according to the output. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J13/NO4. The heat exchanger in the hot water cylinder must transfer the maximum heat output at the maximum heat source temperature. In systems with high hot water consumption (multiple dwellings, industrial applications) the cylinder must be set to the maximum peak demand while taking the shut-off times into account. The maximum heat output and the maximum heating water flow must be adhered to! The contactor for the flange heater (E9) in the hot water cylinder should be dimensioned according to the output and must be supplied by the customer. It is controlled (230 V AC) by the heat pump manager via terminals X1/N and J16/NO10. The maximum heat output of the heat pump and the water flow are to be observed. When room temperature controllers are used, the heating element valves / thermostat valves can cause the volume flows in the consumer circuit to fluctuate. These volume flow fluctuations must be compensated for by an overflow valve installed in the heating bypass downstream from the unregulated heating pump main circuit (M13); this must be set by a technician.

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 5/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Integration Diagram: 10211020 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

Air-to-water heat pump, Integration Diagram, Heat pump and immersion heater
Legend:
1. 1.1 1.2 1.3 1.4 1.5 1.6 2. 3. 3.1 4. 5. 6. 7. 8. 9. 10. 13. 15. 16. 17. Heat Pump Air-to-water heat pump Brine-to-water heat pump Water-to-water heat pump Reversible air-to-water heat pump Reversible brine-to-water heat pump Reversible water-to-water heat pump Heat pump manager Parallel buffer tank Buffer tank Hot water cylinder Swimming pool heat exchanger Passive cooling station with cooling controller N6 Heating and silent or dynamic cooling Fan convector with 4-wire connection Cooling circuit only Heating circuit only Heat source Hydraulic tower Scalding protection Hydro tower HWK 332 B3 B4 E9 E10 E10.1 E10.2 E10.3 E10.5 F7 K20 K21 M11 M12 M13 M14 M15 M16 M17 M18 M19 MA MZ M21/M22 N1 N2 N3/N4 N6 N12 R1 R2/2.1 R3 R4 R5 R9 R11 R13 SMF TC Y5 Y6 Y7 Y8 Y12 Hot water thermostat Swimming pool thermostat Flange heater, hot water 2nd heat generator (HG2) Immersion heater Oil/gas boiler Solid fuel boiler Solar energy system Safety temperature monitor Contactor for 2nd heat generator Contactor for immersion heater hot water Primary pump for heating operation Primary pump for cooling operation Heat circulating pump for main circuit Heat circulating pump for heating circuit 1 Heat circulating pump for heating circuit 2 Auxiliary circulating pump Cooling circulating pump Hot water circulating pump Swimming pool water circulating pump Mixer open Mixer closed Mixer Heating controller Cooling controller for reversible heat pumps Room climate control stations Cooling controller for passive cooling Solar controller External wall sensor Return flow sensor Hot water sensor Return flow sensor for cooling water Temperature sensor for heating circuit 2 Flow sensor (antifreeze) Flow sensor for cooling water Sensor for heating circuit 3 / bivalent-renewable Dirt trap Room temperature controller Three-way distribution valve Two-way valve Three-way mixing valve Three-way valve (closing time max. 10 sec.) External 4-way reversing valve

Domestic hot water distribution system: DDV 32 EB KPV KPV 25 MMB 25 MMH 25 VTB 25 WWM 25 Dual differential pressureless manifold (up to 2.5 m/h)* Extension module for compact manifold (up to 2.0 m/h)* Compact manifold with overflow valve (up to 1.3 m/h)* In combination with EB KPV (up to 2.0 m/h)* Mixer module, bivalent (up to 2.0 m/h)* Mixer module for heating circuit Manifold bar (up to 2.5 m/h)* Hot water module / unmixed heating circuit (up to 2.5 m/h)*

* Recommended max. heating waterflow

Solarthermics: SST 25 SOLK 1204 SOLPU 1 SOLCU 1 SOLCU 2 T1 T2 T3 Solar station for hot water Collector field Solar station Solar controller Solar controller Temperature sensor (collector sensor) Temperature sensor (cylinder 1) Temperature sensor (cylinder 2 /optional display function)

Glen Dimplex Deutschland GmbH Dimplex Division Am Goldenen Feld 18 95326 Kulmbach

Page 6/6 Subject to change and errors! E-mail: dimplex@dimplex.de Internet: www.dimplex.de

Internet: 29.09.2010 Integration Diagram: 10211020 Phone: +49 (0)9221 709-201 Fax: +49 (0)9221 709-339

You might also like