You are on page 1of 112

Menvier Fire Systems

ONE COOPER
Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on high quality and excellent service. Which is why our brands have earned leading positions in the markets we serve. Cooper Safety specialises in products designed to save lives and protect property in commercial, industrial and residential buildings. Its just one of the seven divisions that continue to uphold our reputation through unparalleled sales support and customer service.

Conventional 5 Conventional Contents 7 Fire Panels 15 Detectors 17 Standard Base 19 Relay Base 21 Remote Indicator 23 Reflective Beam Detectors 25 Callpoints 27 Bells 29 Flush Sounders 31 Sounder and Sounder Beacon 33 Surface Sounders 37 Xenon Beacons 41 LED Beacons 45 Door Retainers

Intelligent Addressable 47 Intelligent Addressable Contents 49 Fire Panels 61 Repeater Panels 65 Sensors 67 Standard Base 69 Sounder Base 71 Sounder Beacon Base 73 Loop Connected Remote Indicator 75 Reflective Beam Detectors 77 Callpoints 79 Wall Sounders 81 Wall Sounder Beacons 83 LED Beacons 85 Interfaces 97 Micro Interfaces

Ancillaries and Test Equipment 103 Heavy Duty Relay Unit 105 Power Supply Unit 107 Loop Tester Kit 108 Addressable Device Programmer

About us

PREVEN

Cooper Safety Fire Systems


Cooper Fire offers a comprehensive range of Menvier fire detection products suitable for a wide range of projects, from a small simple installation to a large complex multi building site. Cooper Fire manufacture a wide range of products and offers complete fire solutions, not just individual components. A complete system can be specified from a single source, confident in the knowledge that all the components have been specifically designed and tested to

It is absolutely vital that all the elements of a fire detection system are fully compatible with each other. To support this philosophy, a large multi-disciplined research and development team is based in the UK at the Cooper Doncaster facility, responsible for the integration of the very latest technology into the design of our comprehensive range of fire products.

LO

ensure they are all fully compatible with each other and will function as a truly integrated fire detection and alarm system.

IO

ERTI N C F

I
C

LPCB
S

AT

ION BO

Conventional Product Range

Conventional Contents
Page 7 Control Panels MF9300 Page 31 Sounder and Sounder Beacon MDS824 and MDS824B

Page 11 Control Panels MF200 and MF400

Page 33 Surface Sounders MWS424SB and MWS424DB

Page 15 Detectors MPD821, MPT951, MFR830 MMT860 and MHT890

Page 35 Low Current Sounder MLC624

Page 17 Standard Base MDB800

Page 37 Xenon Beacons MXB124SB and MXB124DB

Page 19 Relay Base MDB800R

Page 39 Xenon Sounder Beacons MCD524SB and MCD524DB

Page 21 Remote Indicator CIR301

Page 41 LED Beacons MLB124SB and MLB124DB

Page 23 Reflective Beam Detectors MBD50R and MBD100R

Page 43 LED Sounder Beacon MSB124SB and MSB124DB

Page 25 Callpoints MBG914 and MBG917

Page 45 Heavy Duty Door Retainers MDR240 and MDR25L

Page 27 Bells MBM246. MBM248 and MWB824

Page 29 Flush Sounders MFS324 and MFS324W

Conventional System Architecture


The philosophy of a conventional system revolves around dividing the building into a number of areas called zones. The detectors and callpoints within each zone are then wired on dedicated circuits. In the event of a detector or callpoint being triggered, the panel is able to identify which circuit contains the triggered device and thereby indicate which zone the fire alarm has come from. It is then necessary to manually search the indicated zone to pinpoint the exact cause of the fire alarm. Unwanted Alarms Because most conventional detectors are simple two state devices they can only be in either a normal or fire condition. Although modern components and good system design can go some way to reducing potential problems, it is not uncommon for conventional systems to generate unwanted alarms due to certain operating conditions or transient environmental conditions such as the presence of steam near to a smoke detector. A key development aimed at reducing such unwanted alarms has been the multi-criteria detector. Traditionally, detectors were designed to respond to particular fire phenomena such as heat or the presence of smoke. However, Cooper now offer multi-criteria devices, which contain both a smoke sensing element and a thermal sensing element. The fire alarm decision is taken by analysis of the responses from both elements, resulting in improved detection performance as well as greatly enhanced false alarm suppression. Sounder Circuits In addition to the detection circuits, there is also a need for separate circuits of alarm annunciation devices such as sounders and beacons to signal the existence of a fire alarm condition to the building users. For sounder circuit continuity monitoring to function effectively, sounder circuits have to be wired in a single radial circuit, spurs and tees are not permitted. Almost every conventional fire panel will have facilities for more than one sounder circuit and generally the higher the specification of the panel or the higher the number of detection zones provided, the more sounder circuits will be provided. Normally however there will be less sounder circuits than detection zone circuits so it will be necessary for a sounder circuit to provide cover for more than one zone.
Zone 1 Zone 2

This increases installation complexity by forcing the sounder wiring to follow different routes to that of the detector wiring. When designing a conventional system it is important to ensure that the panel has adequate zone capacity for the size and complexity of the building and that the panel can support the intended sounder circuit wiring and loading.

Zone 3

Zone 4

Conventional Product Range

MF9300 Range Control Panel

simple access to connection terminals and batteries

MF9304 control panel

Overview
The Menvier MF9300 is a range of high specification conventional control panels designed for a wide range of building types and sizes at a competitive price. Available in a choice of 2, 4, 8 or 16 zone versions, the MF9300 range is designed for ease of installation and simple operation. All panels can be either surface or flush mounted, without the need of additional bezels or back boxes. System flexibility is emphasised by the availability of matching repeater panels for the 4, 8 and 16 zone panels.

Features
2, 4, 8 or 16 zone panels Matching repeaters available for 4, 8 and 16 zone panels Coincidence detection and non-latching zone features on 4, 8 and 16 zone panels Surface or flush mounting option as standard Up to 32 detectors per zone 72 hour standby as standard 24 hour standby available

MFR9300 repeater panel

Benefits
Designed for ease of installation One man walk test facility Fully compatible with Menvier range of ancillaries

Conventional Control Panel - MF9300 Range

Technical Specification
Code Description Standards MF9302 2 zone control panel EN54 Pt2 & Pt4 1998 EN50130-4:1996 EN500081-1:1992 & EN61000-2-2:1994 Specification Number of Zones Detectors per Zone Number of Alarm Circuits Alarm Circuit Load End of Line Devices 2 32 2 500mA per circuit. 1A total Detection circuits: 12K resistor Alarm lines: 12K resistor Auxiliary Fire Signal Output 1A 24V dc (resistive) single pole changeover contacts. Isolate facility available Auxiliary Fault Output N/A 4 32 2 500mA per circuit. 1A total Detection circuits: 12K resistor Alarm lines: 12K resistor 1A 2 4V dc (resistive) single pole changeover contacts. Isolate facility available 1A 2 4V dc (resistive) single pole changeover contacts Auxiliary Common Output Auxiliary dc Output Repeater output 24V dc pull to 0V. Max 10mA 24V dc fused. 100mA N/A 24V dc pull to 0V. Max 10mA 24V dc fused. 100mA 2 wire serial link (repeater also requires separate 230V ac supply) Mains Input Voltage System Operating Voltage Standby Duration Battery Recharge Period Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Cable entries ABS/Polycarbonate housing & back box 344mm x 395mm x 95mm 10.6kg IP20 Top: 13 x 20mm knockouts Back: 1 x 20mm knockout ABS/Polycarbonate housing & back box 344mm x 395mm x 114mm 10.6kg IP20 Top: 13 x 20mm knockouts Back: 1 x 20mm knockout ABS/Polycarbonate housing & steel back box 386mm x 395mm x 114mm 16.8kg (24 hours option 16.0kg) IP20 Top: 27 x 20mm knockouts Back: 1 x 20mm knockout ABS/Polycarbonate housing & steel back box 386mm x 395mm x 114mm 16.9kg (24 hours option 16.0kg) IP20 Top: 27 x 20mm knockouts Back: 1 x 20mm knockout -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH 230V ac 10%. 50/60Hz 24V dc 72 hours 2 x 7Ah sealed lead acid battery 24 hours 230V ac 10%. 50/60Hz 24V dc 72 hours 2 x 7Ah sealed lead acid battery 24 hours 8 32 4 500mA per circuit. 2A total Detection circuits: 12K resistor Alarm lines: 12K resistor 1A 24V dc (resistive) single pole changeover contacts. Isolate facility available 1A 24V dc (resistive) single pole changeover contacts 24V dc pull to 0V. Max 10mA 24V dc fused. 350mA 2 wire serial link (repeater also requires separate 230V ac supply) 230V ac 10%. 50/60Hz 24V dc 72 hours (24 hours option) 2 x 12Ah sealed lead acid battery 24 hours 16 32 4 500mA per circuit. 2A total Detection circuits: 12K resistor Alarm lines: 12K resistor 1A 24V dc (resistive) single pole changeover contacts. Isolate facility available 1A 24V dc (resistive) single pole changeover contacts 24V dc pull to 0V. Max 10mA 24V dc fused. 350mA 2 wire serial link (repeater also requires separate 230V ac supply) 230V ac 10%. 50/60Hz 24V dc 72 hours (24 hours option) 2 x 12Ah sealed lead acid battery 24 hours MF9304 4 zone control panel EN54 Pt2 & Pt4 1998 EN50130-4:1996 EN500081-1:1992 & EN61000-2-2:1994 MF9308 8 zone control panel EN54 Pt2 & Pt4 1998 EN50130-4:1996 EN500081-1:1992 & EN61000-2-2:1994 MF9316 16 zone control panel EN54 Pt2 & Pt4 1998 EN50130-4:1996 EN500081-1:1992 & EN61000-2-2:1994

Note:

If a repeater panel is required to operate with the MF9304, use the MFR9308, 8 zone repeater.

Dimensions
D1 D2 W

Description H (mm) W (mm) D1 (mm) D2 (mm) MF9302 344 395 25 70 MF9304 344 395 25 70 MF9308 386 395 25 119 MF9316 386 395 25 119 MFR9308 386 395 25 119 MFR9316 386 395 25 119 Description MF9302 MF9304 MF9308 MF9316 Note: Cut-out (mm) 324 x 385 324 x 385 376 x 385 376 x 385

If surface mounting add D1 and D2 to obtain depth dimension.

Product Codes
Code MF9302 MF9304 MF9308 MF9316 MF9308L MF9316L MFR9308 MFR9316 MFALOG Description Conventional 2 zone control panel Conventional 4 zone control panel Conventional 8 zone control panel Conventional 16 zone control panel Conventional 8 zone control panel (24 hour standby) Conventional 16 zone control panel (24 hour standby) Conventional 8 zone repeater panel Conventional 16 zone repeater panel Fire alarm system log book

Conventional Control Panel - MF9300 Range

Installation
1. A full set of installation and user instructions is supplied with each panel to assist the installer to carry out the work efficiently and safely, and the end user to perform routine tests. 2. Panels are designed to be wall mounted. When surface fixed use keyhole slot mounting holes found on back of housing, if recessed mounted use an appropriate cut-out for panel and fixed via 6 x screw fixing holes around the housing flange. 3. Mains power supply cable must be routed via the designated 20mm conduit entry knockouts on the top or rear of the housing. The mains terminal block is provided with fuse protection. 4. Conduit entry knockouts are provided on the top of the housing for zone, alarm and output cables. A total of 13 (2/4 zone) or 27 (8/16 zone) knockouts are provided. 5. Standby batteries are connected via push-on terminal connectors. 6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring. 7. Front cover is screw fixed with hinged battery compartment door and hinged upper door for access to zone/alarm connections and configuration settings, which requires use of a special tool for access.

one zone (except 2 zone panel). An alarm condition is dependant upon a fire signal from 2 detectors within a defined period, when facility is selected. A single detector fire signal is indicated by sounding the integral buzzer and flashing LED on the panel. Any fire signal from a manual callpoint on the zone immediately operates the alarm. 7. An alarm line delay feature can be selected (except 2 zone panel). Preset delays of 1 to 7 minutes can be programmed during commissioning, permanently illuminating a panel indicator when set. Indicator and zone LED flash when fire signal is received and delay is in operation. Any fire signal from a manual callpoint immediately operates the alarm.

Repeater Panels
1. Repeaters match the style and appearance of main control panels. 2. Facility for signalling to repeater panels provided on all main panels (except 2 zone). 3. Displays essential information at other key locations in a large building/site. Zone fire or fault conditions Zones or alarm lines in test mode Zones or alarm lines in disabled mode Alarm delays Faults, isolations and test mode for control outputs 4. Repeater panel requires only a single pair of wires to receive signals from main control panel, plus local mains power supply, reducing cost of installation.

User Interface
1. Stylish and attractive panel with easy to use 8 button keypad to control all functions. 2. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication. 3. Panel can be surface mounted or recessed, without the need of an additional fixing bezel or back box. 4. Special tool used to release hinged upper door to access connections and configuration settings or bottom door to access battery.

System Functionality
1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. Service engineer and configuration modes accessed by further security codes. 2. Supervisor mode provides access to test mode, where zones can be tested individually or in any combination. 3. One man walk test feature permits each manual callpoint and detector on the zone(s) in test mode to be put into fire condition and activates the alarms for 2 seconds. Panel automatically resets the zone(s) 10 seconds after each device has been tested. A fire condition received from a zone not in test mode results in an immediate alarm, overriding the test mode. 4. Supervisor mode also provides facility to disable/isolate the following for maintenance or other purposes each detection zone independently the alarm circuits the remote signal output (except 2 zone panel) 5. Non-latching zone facility can be selected on one zone, enabling the direct interconnection of panels in a simple network. 6. Coincidence detection facility can be selected on

Interface Options
1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change. 2. Auxiliary 1A 24V dc fault relay (except 2 zone panel). 3. Remote signal 1A 24V dc relay for remote location signalling, or operation of a remote dialler (can be isolated during tests/servicing). 4. 24V dc common output provided (does not operate with non-latching zone). 5. Auxiliary 24V dc output power supply provided as standard.

Detection Capacity
1. Up to 32 detectors per zone. End of line monitoring devices must be fitted and are supplied as standard. 2. Detector circuits are monitored for open circuit, short circuit and detector removal.

Alarm Capacity
1. 2 separate alarm lines on 2 and 4 zone panels. 500 mA maximum load per line. 2. 4 separate alarm lines on 8 and 16 zone panels. 500mA maximum load per line. 3. Alarm lines are monitored for open circuit and short circuit faults.

Conventional Control Panel - MF9300 Range

Standard Panel Connections


END OF LINE 12K RESISTOR TO DOOR RELEASE UNITS

MDB800 DETECTOR BASE END OF LINE 12K RESISTOR

NC NC

MAR724 HEAVY DUTY RELAY


C C

24V dc 10mA COIL

+
TO APPLICATIONS REQUIRING RELAY WITH ISOLATING FACILITY TO REPEATER PANEL (NOTE 3) REPEATER GROUND REPEATER TRANSMIT

+
(NOTE 1)

MBG914/917 CALLPOINT connect as per instructions

+ subsequent alarm lines

subsequent zones

- + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - +
EARTH
ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ALARM ALARM ALARM ALARM 1 2 3 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

FAULT

NC C NO NC C NO

- +
AUXILIARY COMMON OUTPUT (NOTE 2) AUXILIARY 24V DC OUTPUT

- +
CLASS CHANGE

FAULT REMOTE RELAY SIGNAL RELAY

NOTES: 1. All sounders must be polarised and suppressed. 2. Connection details for door release units when required. 3. Connection details for repeater panels when required.

10

TO VOLT FREE CONTACTS

- VE IN & OUT ON 2

+ VE IN & OUT ON 1

+
230V ac +/- 10% 50/60Hz

Conventional Product Range

MF200 and MF400 Range Control Panels

MAR424 remote fire and fault relay PCB

MF200 control panel

Overview
The Menvier MF200 and MF400 range of conventional control panels offer a competitive solution for smaller installations. Easy to install and operate, the panels are designed to provide fire detection and alarm facilities in buildings where the basic elements of protection to meet BS5839 are required. Available as either a 2 zone or 4 zone panel with up to 20 detectors per zone can be connected. This range of Menvier control panels are conveniently supplied complete with end of line devices and batteries offering 24 hours standby as standard, with the option of 72 hours on the 4 zone version. One man walk test and class change facilities, along with 24V dc remote signalling fire and fault outputs augment a value for money range.

Features
2 or 4 zone panels Competitively priced Supplied complete with battery and end of line devices

Benefits
Simple end user operation One man walk test facility Fully compatible with Menvier range of ancillaries

MAR424 fits inside MF200 and MF400 panels

11

Conventional Control Panels - MF200 and MF400

Technical Specification
Code Description Standards Specification Number of Zones Detectors per Zone Number of Alarm Lines Alarm Circuit Load End of Line Devices 2 20 2 375mA per circuit. 750mA total Detection circuits: 22K resistor Alarm lines: 22K resistor Auxiliary Fire Signal Output Auxiliary Fault Output Auxiliary dc Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc fused. 32mA (up to 100mA at the expense of alarm load) Mains Input Voltage System Operating Voltage Standby Duration Battery 240V ac +10%-15% 24V dc 24 hours 1 x 4Ah sealed lead acid battery 4 20 2 375mA per circuit. 750mA total Detection circuits: 22K resistor Alarm lines: 22K resistor 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA 24V dc fused. 32mA (up to 100mA at the expense of alarm load) 240V ac +10%-15% 24V dc 24 hours (72 hours on MF400-72) 1 x 4Ah sealed lead acid battery (1 x 7Ah on MF400-72) Recharge Period Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Cable entries ABS/Polycarbonate housing. Steel back box. 300mm x 300mm x 74mm 4.8kg IP30 Top: 10 x 20mm conduit entries Bottom: 1 x 20mm conduit entry (mains cable) Back: 1 x mains cable entry slot ABS/Polycarbonate housing. Steel back box. 300mm x 300mm x 74mm 4.8kg (6.0kg on MF400-72) IP30 Top: 10 x 20mm conduit entries Bottom: 1 x 20mm conduit entry (mains cable) Back: 1 x mains cable entry slot -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH 48 hours (80% in 24 hours) 48 hours (80% in 24 hours) MF200 2 zone control panel EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996 MF400 4 zone control panel EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996

Dimensions
D W

H (mm) W (mm) D (mm) 300 300 74

Product Codes
Code MF200 MF400 MF400-72 MAR424 MFALOG Description Conventional 2 zone control panel Conventional 4 zone control panel Conventional 4 zone control panel (72 hour standby) Conventional fire and fault relay PCB Fire alarm system log book

12

Conventional Control Panels - MF200 and MF400

Installation
1. A full set of Installation and user Instructions is supplied with each panel to assist the installer to carry out the work efficiently and safely, and the user to perform routine tests. 2. Panels are wall mounted via keyhole slot mounting holes on back of housing. 3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or bottom of the housing, or via the rear cable entry slot. The mains terminal block is provided with fuse protection. 4. A total of 10 x 20mm conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for unused entries. 5. Standby battery connected via push-on terminal connectors. 6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring. 7. Front cover retained by anti-tamper screws.

User Interface
1. Attractive compact panel with easy to use 5 button keyboard to control all functions 2. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication

Interface Options
1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change. 2. 24V dc outputs provided for remote signalling of fire and fault conditions. 3. Optional relay board available (MAR424) to convert fire and fault signals to volt free change over rated at 24V dc, 1A dc. 4. Auxiliary 24V dc output power supply provided as standard.

Detection Capacity
1. Up to 20 detectors per zone. End of line monitoring devices must be fitted and are supplied as standard. 2. Detector circuits are monitored for open circuit, short circuit and detector removal.

System Functionality
1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. 2. Supervisor mode provides access to test mode, where zones can be tested individually. 3. One man walk test feature permits each manual callpoint and detector on the zone in test mode to be put into fire condition and activates the alarms for 2 seconds. Panel automatically resets the zone 10 seconds after each device has been tested. A fire condition received from a zone not in test mode results in an immediate alarm, overriding the test mode. 4. Supervisor mode also provides facility to disable/isolate the following for maintenance or other purposes each detection zone independently the alarm circuits the remote signal outputs

Alarm Capacity
1. Two separate alarm lines, each with a maximum rated load of 375mA. 2. Alarm lines are monitored for open circuit and short circuit faults.

13

Conventional Control Panels - MF200 and MF400

Standard Panel Connections


SWITCH /CONTACTOR/TIMER (APPLY NO VOLTAGE) END OF LINE 22KOhm RESISTOR MDB800 DETECTOR BASE FAULT SIGNAL
24V dc 10mA PULL TO 0V DOOR RELEASE UNITS RELAY OUTPUTS 240V dc 10A

NC C NO NO C NC

MAR724

ISOLATING FIRE SIGNAL

+
24V dc AUXILARY SUPPORT
24V 10mA COIL

END OF LINE 22KOhm RESISTOR

+ VE IN & OUT ON 1

- VE IN & OUT ON 2

+ -

+ -

MAR724 MAR424 24V 10mA

AUX FAULT / REMOTE SIGNAL

AUX FAULT / REMOTE SIGNAL

MBG914/917 CALLPOINT connect as per instuctions

AUX FAULT

RELAY OUTPUTS 24V 1A (resistive)

REMOTE SIGNAL

NC

NO

NC

NO

subsequent zones

subsequent alarm lines


24V 10mA COIL

MAR424

+ -

E
24V 10mA COIL

+ -

+ ZONE 1

+ ZONE 2

+ ZONE 3*

+ ZONE 4*

+ -

+ -

+ -

+ REM SIG

+ -

+ AUX DC

+ -

+ -

ALARM 1

ALARM 2

AUX FAULT

CLASS CHANGE

AUX FAULT

REMOTE SIGNAL

* MF400 ONLY

C = COMMON NC = NOT NORMALLY CONNECTED NO = NORMALLY OPEN

14

Conventional Product Range

Detectors

optical / photo-thermal / heat detectors

Overview
The Menvier range of conventional detectors have been specifically designed to operate with Menvier control panels. The Menvier optical detector MPD821 is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. innovative light pipe technology allows LED to be seen from any angle The Menvier photo-thermal detector MPT951 will respond quickly to fast clean burning fires yet maintain the advantage of optical detectors when detecting smouldering fires. The thermal enhancement of this detector allows a higher alarm threshold which provides a greater rejection of false alarms. The detector will also raise an alarm at temperatures exceeding 60C. The Menvier fixed heat detectors MMT860 and MHT890 will detect temperatures above 77C and 92C. The rate of rise heat detector MFR830 is used to detect rapid increases in temperature with a maximum threshold of 60C. These detectors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.

Features
Quick and simple to install Stylish low profile design 360 viewable LED Removable detector chamber Drift compensation

Benefits
Clean me feature means detector can be cleaned on site using the Menvier manual cleaning procedure Common mounting base Positive lock indication

15

Conventional Detectors

Technical Specification
Code Description Standards Supply Ratings Operating Voltage Standby Current Startup Current Alarm Current Fixing Information Mounting Position Mounting Options Area Coverage System Wiring Operation Detection Mode Light scatter principle Light scatter principle & Heat sensitive element Heat Class Alarm Temperature Indication Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions Excl Base (Dia x H) Dimensions Incl Base (Dia x H) Ingress Protection EMC Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems PC/ABS White 101mm x 33mm 101mm x 45mm IP40 CE Marked PC/ABS White 101mm x 43mm 101mm x 55mm IP40 CE Marked PC/ABS White 100mm x 43mm 100mm x 55mm IP40 CE Marked PC/ABS White 101mm x 43mm 101mm x 55mm IP40 CE Marked PC/ABS White 101mm x 43mm 101mm x 55mm IP40 CE Marked -20C to 60C 0 to 93% RH -20C to 45C 0 to 93% RH -20C to 45C 0 to 93% RH -20C to 60C 0 to 93% RH -20C to 75C 0 to 93% RH N/A N/A 360 visible LED A2S 60C 360 visible LED A2R 60C 360 visible LED BS 77C 360 visible LED CS 92C 360 visible LED Heat sensitive element Heat sensitive element Heat sensitive element Ceiling in open areas Surface mount with MDB800 base 100m (subject to local standards) 2 Core Ceiling in open areas Surface mount with MDB800 base 100m (subject to local standards) 2 Core Ceiling in open areas Surface mount with MDB800 base 50m (subject to local standards) 2 Core Ceiling in open areas Surface mount with MDB800 base 50m (subject to local standards) 2 Core Ceiling in open areas Surface mount with MDB800 base 50m (subject to local standards) 2 Core 15V dc to 30V dc 30A (max) 340A (max) 25mA (max) 15V dc to 30V dc 30A (max) 340A (max) 25mA (max) 15V dc to 30V dc 30A (max) N/A 25mA (max) 15V dc to 30V dc 30A (max) N/A 25mA (max) 15V dc to 30V dc 30A (max) N/A 25mA (max) MPD821 Optical smoke Detector EN54 Pt7 2000, A1 2002 MPT951 Photo-thermal detector EN54 Pt 5 & Pt 7 2000, A1 2002 MFR830 Rate of rise detector EN54 Pt 5 2000, A1 2002 MMT860 Fixed heat detector (77C) EN54 Pt 5 2000, A1 2002 MHT890 Fixed heat detector (92C) EN54 Pt 5 2000, A1 2002

Dimensions
Dia

Installation
1. Detectors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised detector removal without the use of a special tool. 4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base. Note: For wiring information please see MDB800 base.

User Interface
1. Red LED to indicate alarm condition. 2. Amber LED to indicate chamber fault/drift compensation limit (enhanced versions only). 3. All wiring connections are via a common mounting base (supplied separately).

Description Optical Photo-thermal Heat

Dia (mm) 101 101 101

D (mm) D (mm) (excl base) (incl base) 33 45 43 55 43 55

Product Codes
Code MPD821 MPT951 MFR830 MMT860 MHT890 MDB800 MDP201 Description Conventional optical smoke detector Conventional photo-thermal detector Conventional rate of rise heat detector Conventional fixed heat detector (77C) Conventional fixed heat detector (92C) Conventional detector base Duct Probe

16

Conventional Product Range

Standard Base MDB800


Suitable detectors for use with the MDB800 standard base

MPD821 optical detector

MDB800 standard base

Overview
MPT951 photo-thermal detector The MDB800 Menvier conventional base has been specifically designed to be compatible with the Menvier range of conventional detectors. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity. The base has a spring contact switch and a parallel zener diode to enable fault monitoring. MFR830, MMT860, MHT890 heat detectors

Features
Quick and simple to install Separate zone in and zone out terminals Stand off fixing feature Selectable detector locking

Benefits
Accepts side entry surface cables Common base for Menvier conventional detectors

17

Conventional Standard Base - MDB800

Dimensions
Dia (mm) 104
D

Technical Specification
D (mm) 22
Code Description Physical Construction Colour Dimensions (Dia x D) Compatibility Suitable for use with Menvier conventional detectors PC/ABS White 104mm x 22mm MDB800 Standard base

Dia

Installation
1. Base incorporates a retaining clip to provide positive feedback when detector is correctly fitted. 2. Separate terminals are provided for zone in and zone out connections. 3. Each terminal can accept up to 2 x 2.5mm cables 4. Base incorporates a substantial cable entry aperture in the rear of the base. 5. Breakouts are provided to enable the detector base to sit neatly over surface cables and then enter via the rear entry aperture. 6. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 7. Fixings are suitable for standard BESA box or direct fixing to suitable surface 8. Optional locking devices (supplied with base) to prevent unauthorised detector removal.

Interface Options
1. Menvier conventional detectors and bases support the use of a remote LED (optional extra CIR301).

Standard Connection
+ VE +
remote indicator (optional)

Compatible Menvier Conventional Control Panel

ZONE

4 2 3 E 2 3 E

- VE

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code MDB800 MDB800*10 CIR301 Description Conventional standard base Conventional standard base (pack of 10) Conventional remote indicator

18

end of line resistor

LED

LED

Conventional Product Range

Relay Base MDB800R


Suitable detectors for use with the MDB800R relay base

MPD821 optical detector

MDB800R relay base

Overview
MPT951 photo-thermal detector The MDB800R Menvier conventional relay base has been specifically designed to be compatible with the Menvier range of conventional detectors. This relay base as been designed for flexibility, simplicity and speed of installation. It provides a local relay signal in the event of its host detector being triggered, making it ideal for instigating a local response.

Features
Quick and simple to install Designed specifically for use with Menvier detectors Provides remote signal for external interfacing

Benefits
First fix mounting plate for ease of installation Local control output from host detector

MFR830, MMT860, MHT890 heat detectors

19

Conventional Relay Base - MDB800R

Dimensions
Dia (mm) 102
D

Technical Specification
Code MDB800R Relay base

D (mm) 40

Description Specification Relay Contact Rating Relay Trigger Source Detector Locking Facility Physical Construction Colour

1A at 24V dc Detector remote LED output Supplied as standard

PC/ABS White 102mm x 40mm

Dia

Dimensions (Dia x D) Compatibility Suitable for use with

Menvier conventional detectors

Installation
1. Relay base is supplied with a first fix fixing plate. 2. Fixing plate has a central cable aperture. 3. Cable entry is from rear. 4. Main body is then clipped into place on base, body locks into place when pressed into position.

Interface Options
1. Bases are compatible with latest generation conventional Menvier detectors.

System Functionality
1. Relay is controlled by status of host detector. 2. If host detector is triggered relay activates.

Standard Connection
+ VE +
remote indicator (optional)

Compatible Menvier Conventional Control Panel

ZONE

4 2 3 E 2 3 E

- VE

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code MDB800R Description Conventional relay base

20

end of line resistor

LED

LED

Conventional Product Range

Remote Indicator CIR301

CIR301 remote indicator

Overview
The CIR301 conventional remote indicator is designed to provide discreet remote indication for use with Menvier conventional detectors. The remote indicator is ideal for applications such as void spaces or outside locked or inaccessible rooms to provide indication of the activation of an automatic detector.

Features
Quick and simple to install Wide viewing angle high brightness LED Attractive styling

Benefits
High profile LED Fits onto standard single gang back box

21

Conventional Remote Indicator - CIR301

Dimensions
D

Technical Specification
H (mm) W (mm) D (mm) 87 87 30
Code Description Environmental Operating Temperature -10C to +55C 0 to 95% RH CIR301 Remote indicator

Humidity (Non Condensing) Physical Construction Colour


W

ABS White Red 87mm x 87mm x 30mm 0.28kg IP30

Lens Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

Menvier conventional fire systems

Standard Connection
CIR301
+ VE

Installation
1. Mounting plate fixes to single gang back box or can be direct fixed to wall or ceiling. 2. Cable entry is normally from rear but breakouts are provided in side of base plate. 3. Cables connect to terminals on PCB within base plate. 4. Front cover is pushed onto base plate and locks in place.

System Functionality
1. The remote indicator is connected to an individual detector. 2. The remote indicator activates if detector is triggered. 3. LED cancels when detector is reset. 4. Low current consumption.

+
remote indicator (optional)

Compatible Menvier Conventional Control Panel

+
ZONE 2

LED

4 E 3

- VE

IN
Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

DETECTOR BASE

Terminal block unplugs for ease of connection

Product Codes
Code CIR301 M1R195B Description Conventional remote indicator Conventional remote indicator (with buzzer)

22

Conventional Product Range

Reflective Beam Detectors MBD50R and MBD100R

optional mounting bracket with cable clamp facilities

MBD50R and MBD100R reflective beam detectors

Overview
The Menvier range of zone powered reflective beam detectors are specifically designed to be compatible with the full range of conventional Menvier control panels. Two versions are available, the MBD50R with a range of up to 50 metres, and the MBD100R with a range of 50 - 100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard zone wiring so no additional interconnection is required. In normal operation only one beam detector may be connected per zone, however special versions are available to work with external power supply if multiple beam detectors are required to be connected to a single zone.

Features
Quick and simple to install Simple two wire connection No power supply required

Benefits
Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance

combined transmitter and receiver for ease of installation

23

Conventional Reflective Beam Detector - MBD50R and MBD100R

Dimensions
H (mm) W (mm) D (mm) 210 130 120
H D

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current Alarm Current Alignment Current 18V dc to 30V dc <5mA (no LEDs illuminated) <9mA <18mA 20 seconds (approx) 5 to 50 metres 18V dc to 30V dc <5mA (no LEDs illuminated) <9mA <18mA 20 seconds (approx) 50 to 100 metres MBD50R Reflective beam detector EN54 Pt 12 2002 MBD100R Reflective beam detector EN54 Pt 12 2002

Power up Time Operating Range Tolerance to Beam Misalignment at 35% Fire Alarm Thresholds Optical Wavelength Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

Detector 0.8, Prism 5.0 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 880nm

Detector 0.8, Prism 5.0 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 880nm

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

PC/ABS White 210mm 130mm x 120mm 0.8kg IP40

PC/ABS White 210mm 130mm x 120mm 0.8kg IP40

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MBD50R / MBD100R
to beam detector socket

Installation
1. Must be fixed to solid structure. 2. Recommended mounting height is 0.3 to 0.6 metres below the ceiling. 3. Only 1 conventional reflective beam allowed per control panel zone, if multiple beams per zone required, special externally powered version available. 4. Cables can be terminated into separate termination box (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately. 5. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector. 6. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation.

System Functionality
1. Beam detectors have 3 modes Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly. Alignment mode Enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator. Normal running mode

+ - + Compatible Menvier Conventional Control Panel

ZONE IN

IN EOL DEVICE WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of zone.

User Interface
1. Beam detector status LEDs Red LED constantly illuminated indicates fire condition. Flashing amber LED indicates fault condition.

Interface Options
1. Conventional beam detectors are connected directly to the Menvier conventional panel.

Product Codes
Code MBD50R MBD100R MRBFP Description Conventional reflective beam detector, 50m range Conventional reflective beam detector, 100m range Mounting bracket

24

Conventional Product Range

Callpoints MBG914 and MBG917

MBG917 weatherproof callpoint

MBG914 callpoint

Overview
This attractively designed, simple to install, range of callpoints have been specifically developed to be compatible with Menvier conventional fire panels. There are 2 versions of callpoint in this range. The MBG914 which can be either surface or flush mounted and the MBG917 which is a weatherproof version. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications.

Features
High visibility status LED Standard and weatherproof versions available Wide range of accessories Heavy duty terminals

MBGHCC protective hinged cover

Benefits
Quick and simple to install Fast fit clip on front cover Single tool for test and access

MBGBEZ recessing bezel

25

Conventional Callpoints - MBG914 and MBG917

Dimensions
W

Technical Specification
Code Description Standards Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc MBG914 Surface/flush mount callpoint EN54 Pt11 MBG917 Weatherproof callpoint EN54 Pt11

Environmental Operating Temperature Humidity (Non Condensing) Physical -10C to +55C 0 to 93% RH -25C to +70C 0 to 93% RH

Construction Colour

PC/ABS Red 87mm x 87mm x 57mm (36mm flush) 0.2kg IP42

PC/ABS Red 87mm x 87mm x 59mm 0.2kg IP65

Description H (mm) Flush mounted 87 Surface mounted 87 Weatherproof 87

W (mm) 87 87 87

D (mm) 36 57 59

Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MBG914 / MBG917
COMMON

Installation
1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate zone in and zone out terminals are provided for all connections. 7. Surface/flush callpoints are IP42, weatherproof is IP65.

Accessories
Semi recess bezel Spacer plates Hinged clear cover Resettable plastic element Replacement test key Replacement glass elements Earth continuity links

470

+ + - - - Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: 470 connection is for standard Menvier conventional panels. 4V7 connection can be used with MF9300 to enable certain features on the Menvier MF9300 range of control panels.

4V7

User Interface
1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element.

Product Codes
Code MBG914 MBG917 MBGHCC MBGSP MBGBEZ MBGREKIT MBG118 MBG119 MFBGKEY3 Description Conventional surface/flush callpoint Conventional weatherproof callpoint Protective hinged cover Spacer plates (pack of 10) Recessing bezels (pack of 10) Resettable element kit (pack of 10) Spare break glasses (pack of 5) Earth continuity links (pack of 5) Callpoint keys (pack of 10)

26

Conventional Product Range

Bells MBM246, MBM248 and MWB824

MWB824 weatherproof bell

MBM246 and MBM248 internal bells

Overview
Bells still remain a popular choice for many applications such as schools where they can sometimes be used as a signal for non fire purposes such as class change. MBM246 and MBM248 The MBM246 and MBM248 Menvier internal bells incorporate highly efficient rotary centrifugal movements combining high sound output with low current consumption. MWB824 The MWB824 Menvier weatherproof bell enables a common bell sound to be achieved throughout a complete site, including areas where a weatherproof device is required.

Features
Quick and simple to install High sound output Low current consumption Multi-fixing base plate (internal) IP42 rated (internal) IP54 rated (weatherproof)

Benefits
Can be used for non fire applications

27

Conventional Bells - MBM246, MBM248 and MWB824

Dimensions
D
Dia

Technical Specification
Code Description Standards Specification MBM246 Internal 6 Inch bell EN54 Pt3 MBM248 Internal 8 Inch bell EN54 Pt3 MWB824 Weatherproof 8 Inch bell EN54 Pt3

Dia

Operating Voltage Current Consumption Sound Output Environmental


D

24V dc 25mA at 24V dc 93-95dB(A) at 24V dc

24V dc 28mA at 24V dc 95-97dB(A) at 24V dc

24V dc 28mA at 24V dc 95dB(A) (+/-2)

Operating Temperature Humidity (Non Condensing)

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

Internal bell

Weatherproof bell

Physical Construction Colour Dimensions (Dia x D) gong - steel / base-polycarbonate Red 152mm x 63mm 0.85kg IP21C Rear gong - steel / base-polycarbonate Red 203mm x 67mm 1.7kg IP21C Rear stove enamelled Red 200mm x 104mm 0.49kg IP54 Via separate back box

Description 6 inch internal bell 8 inch internal bell 8 inch weatherproof bell

Dia (mm) 152 203 200

D (mm) 63 67 104

Weight Ingress Protection Cable Entry Compatibility Suitable for use with

Menvier conventional fire systems

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MBM246 / MBM248 / MBM824
- - + +
Compatible Menvier Conventional Control Panel

Installation
MBM246 / MBM248 1. Multiple rear fixing options, can be fixed direct to wall or mounted on suitable BESA box. 2. Cable entry into bell is from rear. 3. Incorporates heavy duty terminals suitable for 2.5mm cables. MWB824 1. Supplied with heavy duty gasketed back box which supports bottom entry cables. 2. Incorporates heavy duty terminals.

Device Functionality
MBM246 / MBM248 1. Sound output is fixed and determined by size of the bell. 2. Operation is driven by an internal motor and striker arrangement. 3. Bells are polarised and suppressed. MWB824 1. Bell operates via solenoid. 2. Bell is polarised and suppressed.

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable

Product Codes
Code MBM246 MBM248 MWB824 Description Conventional internal 6 Inch bell Conventional internal 8 Inch bell Conventional weatherproof 8 Inch bell

28

Conventional Product Range

Flush Sounders MFS324 and MFS324W

MFS324W white flush sounder

MFS324 red flush sounder

Overview
The Menvier discreet flush sounder is designed to be compatible with Menvier conventional fire systems. Available in a choice of colours MFS324 red and MFS324W white. These flush sounders provide an excellent combination of high sound output and discreet appearance. Ideal for retail, hotel and residential applications such as sheltered housing.

Features
Choice of colours Separate volume control Choice of tone is determined by selection of appropriate terminal for negative connection

Benefits
Quick and simple to install Low profile design

29

Conventional Flush Sounder - MFS324 and MFS324W

Dimensions
W D

Technical Specification
H (mm) W (mm) D (mm) 86 86 36
Code Description Standards Specification Operating Voltage
H

MFS324 Flush sounder EN54 Pt3

MFS324W Flush sounder EN54 Pt3

6V dc to 28V dc 20mA at 24V dc 98dB(a) at 1 Metre (+/- 2)

6V dc to 28V dc 20mA at 24V dc 98dB(a) at 1 Metre (+/- 2)

Current Consumption Sound Output Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

-25C to +55C 0 to 95% RH

-25C to +55C 0 to 95% RH

ABS Red 86mm x 86mm x 36mm 0.3kg IP20 Via separate back box

ABS White 86mm x 86mm x 36mm 0.3kg IP20 Via separate back box

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MFS324 / MFS324W
2nd SOUND 1st SOUND COMMON

Installation
1. Sounder fixes to a single gang deep back box. 2. Fixing screws included. 3. Connections are to main sounder body. 4. Separate loop in and loop out terminals are provided. 5. For surface mount applications a separate red single gang box can be ordered separately.

Interface Options
1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

+ + - - - Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MFS324 MFS324W MFSSBB Description Conventional flush sounder, red Conventional flush sounder, white Back box, red

30

Conventional Product Range

Sounder and Sounder Beacon MDS824 and MDS824B

MDS824B sounder beacon with conventional detector and base

MDS824 base mountable sounder

MDS824B sounder beacon with blanking plate (MDS824COV)

Overview
The Menvier base mountable sounder and sounder beacon have a slim and aesthetically pleasing design and can be installed as either as a discreet stand alone sounder / sounder beacon or ceiling mounted as shown, with detector and base. When mounted with a detector and base it simplifies the installation of the system by enabling a detector and sounder to be fixed at a single common point. When used as a stand alone sounder the device can be either wall or ceiling mounted and completed with an optional cover plate (MDS824COV). The sounder is ideal for applications such as hotel bedrooms or where a detector sounder / sounder beacon is required.

Features
Quick and simple to install Low profile design Discreet appearance Blanking plate available when used as a stand alone sounder

Benefits
Single installation point Can be wired as a stand alone unit

31

Sounder and Sounder Beacon - MDS824 and MDS824B

Dimensions
Dia

Technical Specification
Dia (mm) 111 D (mm) 26
Code Description Standards Specification MDS824 Sounder EN54 Pt3 MDS824B Sounder beacon EN54 Pt3

Operating Voltage Current Consumption Sound Output Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

10V dc to 28V dc 5mA (low) 7 ma (high) at 24V 80/90dB(a) (+/-3) @ 1 Metre

10V dc to 28V dc 7mA (low) 10 ma (high) at 24V 80/90dB(a) (+/-3) @ 1 Metre

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

ABS White 111mm x 26mm 0.4kg IP30 Rear

ABS White 111mm x 26mm 0.4kg IP30 Rear

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MDS824 / MDS824B
2nd SOUND 1st SOUND COMMON

Installation
1. Sounder/beacon fixes to mounting surface. 2. Cables pass through the middle of the sounder. 3. Sounder/beacon wiring terminates at the sounder terminals. 4. Detector wiring terminates at normal connections on detector base. 5. If no detector is to be fitted, a blanking plate can be fitted instead.

Interface Options
1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

- - - - + +
Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MDS824 MDS824B MDS824COV Description Conventional sounder Conventional sounder beacon Blanking plate (pack of 5)

32

Conventional Product Range

Surface Sounders MWS424SB and MWS424DB

MWS424DB weatherproof surface sounder

MWS424SB low profile surface sounder

Overview
These general purpose conventional surface sounders have been specifically designed to work with Menvier conventional control panels. MWS424SB The MWS424SB is a low profile surface sounder. Volume is adjustable via the internal volume control and 32 different alarm tone selections are provided. low profile base Depending on the selected tone, sound levels of up to 105dB(A) can be achieved. MWS424DB The MWS424DB is a weatherproof (IP65) surface sounder. Volume is adjustable via the internal volume control and 32 different alarm tone selections are provided. Depending on the selected tone, sound levels of up to 105dB(A) can be achieved.

Features
MWS424SB Low profile design Pre drilled cable entries 32 selectable tones MWS424DB Weatherproof version (IP65) Choice of cable entry positions 32 selectable tones

Benefits
Low current, high sound output Suitable for a wide range of applications Automatic synchronisation

weatherproof base

33

Conventional Surface Sounders - MWS424SB and MWS424DB

Dimensions
D

Technical Specification
D

Code Description Standards Specification Operating Voltage Current Consumption Sound Output Number of Tones

MWS424SB Low profile surface sounder EN54 Pt3

MWS424DB Weatherproof surface sounder EN54 Pt3

9V dc to 28V dc 16mA at 24V dc 105dB(a) max (+/-2) at 24V dc 32

9V dc to 28V dc 16mA at 24V dc 105dB(a) max (+/-2) at 24V dc 32

Dia

Dia

Environmental Operating Temperature -25C to +70C 0 to 93% RH -25C to +70C 0 to 93% RH

Low profile surface sounder

Weatherproof surface sounder D (mm) 63 93

Humidity (Non Condensing) Physical Construction Colour

PC/ABS Red 93mm x 63mm 0.24kg IP54 Rear

PC/ABS Red 93mm x 93mm 0.3kg IP65 Rear/side

Description Dia (mm) Low profile surface sounder 93 Weatherproof surface sounder 93

Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MWS424SB / MWS424DB
2nd SOUND 1st SOUND COMMON

Installation
MWS424SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main sounder body. 5. Separate zone in and zone out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. MWS424DB 1. Supplied with simple to install first fix mounting base. 2. To maintain weatherproof integrity, fixing holes are drilled upon installation. 3. Cable entry can be rear or side. 4. Connections are to main sounder body. 5. Separate zone in and zone out terminals are provided. 6. Main sounder body is pushed into mounting base and twisted to lock.

Interface Options
MWS424SB / MWS424DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

+ + - - - Compatible Menvier Conventional Control Panel

Options
MWS424SB / MWS424DB 1. Choice of tone setting (set via DIP switches can be altered at any time).

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MWS424SB MWS424DB Description Conventional low profile surface sounder Conventional weatherproof surface sounder

34

Conventional Product Range

Low Current Sounder MLC624

MLC624 low current sounder

Overview
The MLC624 Menvier low current sounder has been designed to provide a high sound output with a low current consumption. It is ideal for applications where high sound levels need to be achieved but where available sounder circuit capacity is limited. The low current sounder is simple to install and uses a first fix back plate onto which the main body attaches with a self locking press fix assembly.

Features
Quick and simple to install Low current consumption High efficiency design 3 different tones Separate volume control

Benefits
Low current, high sound output Automatic synchronisation Self locking assembly

35

Conventional Low Current - MLC624

Dimensions
D

Technical Specification
H (mm) W (mm) D (mm) 105 105 95
Code Description Standards Specification
H

MLC624 Low current sounder EN54 Pt3

Operating Voltage Current Consumption Sound Output Environmental

12V dc to 30V dc 5mA at 24V dc 100dB(a) at 24V dc

Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

-25C to +70C 0 to 93% RH

PC/ABS Red 105mm x 105mm x 95mm 0.25kg IP42 Rear or top/bottom

Menvier conventional fire systems

Standard Connection
MLC624
2nd SOUND 1st SOUND COMMON

Installation
1. First fix mounting plate is fixed to wall. 2. Cable entry is from rear, or top/bottom. 3. Connections are to main sounder body. 4. Separate alarm line in / out terminals are provided.

Interface Options
1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

+ + - - - Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MLC624 Description Conventional low current sounder

36

Conventional Product Range

Xenon Beacons MXB124SB and MXB124DB

MXB124DB weatherproof xenon beacon

MXB124SB low profile xenon beacon

Overview
This range of Menvier xenon beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. Xenon beacons have a high light output to maximise the attention attracting potential of the device. low profile base MXB124SB The MXB124SB low profile xenon beacon features a high performance light source. Pre-drilled fixing and cable entry holes it is simple to install. MXB124DB The MXB124DB weatherproof xenon beacon is IP65 rated and supports side entry surface cables making it ideal for industrial applications. Lower power LED variants are also available which offer a lower current consumption but have a consequently lower light output than traditional xenon types (MLB124SB and MLB124DB LED beacons).

Features
MXB124SB Unobtrusive low profile design High output xenon beacon Pre drilled cable entries entry holes MXB124DB Weatherproof version (IP65) High output xenon beacon Choice of cable entry positions

Benefits
first fix base Compatible with range of Menvier fire detection panels Weatherproof version

weatherproof base

37

Conventional Xenon Beacons - MXB124SB and MXB124DB

Dimensions

Technical Specification
Code Description Specification Operating Voltage 24V dc 45mA at 24V dc Continuous 1.45J 60 per minute 24V dc 45mA at 24V dc Continuous 1.45J 60 per minute MXB124SB Low profile xenon beacon MXB124DB Weatherproof xenon beacon

Current Consumption Operation Flash Energy Flash Frequency

Dia
Dia

Environmental Operating Temperature -20C to +55C 0 to 93% RH -20C to +55C 0 to 93 RH

Low profile xenon beacon

Weatherproof xenon beacon D (mm) 72 101

Humidity (Non Condensing) Physical Construction Colour

PC/ABS Red Red 93mm x 72mm 0.2kg IP54 Rear

PC/ABS Red Red 93mm x 101mm 0.25kg IP65 Rear/side

Description Dia (mm) Low profile xenon beacon 93 Weatherproof xenon beacon 93

Lens Colour Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MXB124SB / MXB124DB + + Compatible Menvier Conventional Control Panel

Installation
MXB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. MXB124DB 1. Supplied with simple to install first fix mounting base. 2. Cable entry is from rear or side. 3. Connections are to main beacon body. 4. Separate alarm line in / out terminals are provided. 5. Main body is pushed into sounder base and then twisted to lock into place.

Interface Options
MXB124SB / MXB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable

Product Codes
Code MXB124SB MXB124DB MXB224SB MXB224DB Description Conventional low profile xenon beacon, 1 Watt Conventional weatherproof xenon beacon, 1 Watt Conventional low profile xenon beacon, 2 Watt Conventional weatherproof xenon beacon, 2 Watt

38

Conventional Product Range

Xenon Sounder Beacons MCD524SB and MCD524DB

MCD524DB weatherproof xenon sounder beacon

MCD524SB low profile xenon sounder beacon

Overview
This range of Menvier xenon sounder beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. The key benefit of these devices is that an audible and a visual alarm are combined together and require only a single installation point. This greatly reduces installation time and cost and is much less obtrusive than 2 separate devices. Xenon beacons have a high light output to maximise the attention attracting potential of the device. MCD524SB The MCD524SB low profile xenon sounder beacon features a high performance light source and adjustable volume control. Due to predrilled fixing and cable entry holes it is simple to install. MCD524DB The MCD524DB weatherproof xenon sounder beacon is IP65 rated and features a high performance light source and adjustable volume control. weatherproof base Lower power LED variants are also available which offer a lower current consumption but have a consequently lower light output than traditional xenon types (MSB124SB and MSB124DB LED sounder beacons).

Features
MCD524SB Unobtrusive low profile design High output xenon beacon Pre drilled cable entries Sounder and beacon with a single installation point 32 selectable tones MCD524DB Weatherproof version (IP65) High output xenon beacon Side entry surface cables Sounder and beacon with a single installation point 32 selectable tones

low profile base

Benefits
Combined audio / visual unit Single installation point

39

Conventional Xenon Sounder Beacons - MCD524SB and MCD524DB

Dimensions
D

Technical Specification
D

Code Description Specification Operating Voltage Current Consumption Operation Flash Energy Flash Frequency

MCD524SB Low profile xenon sounder beacon

MCD524DB Weatherproof xenon sounder beacon

18V dc to 30V dc 68mA (av) 73mA (peak) Continuous 0.7J 60 per minute 101dB(a) max (+/-3) at 24V dc 32

18V dc to 30V dc 68mA (av) 73mA (peak) Continuous 0.7J 60 per minute 101dB(a) max (+/-3) at 24V dc 32

Dia

Dia

Sound Output Number of Tones

Low profile xenon sounder beacon Description Low profile xenon sounder beacon Weatherproof xenon sounder beacon

Weatherproof xenon sounder beacon Dia (mm) 93 93 D (mm) 92 121

Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Lens Colour Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems PC/ABS Red Red 93mm x 92mm 0.25kg IP54 Rear PC/ABS Red Red 93mm x 121mm 0.33kg IP65 Rear/side -20C to +55C 0 to 93% RH -20C to +55C 0 to 93% RH

Standard Connection
MCD524SB / MCD524DB
2nd SOUND 1st SOUND COMMON

Installation
MCD524SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. 7. Supply is common for sounder and beacon MCD524DB 1. Cable entry is from rear or side. 2. Connections are to main beacon body. 3. Separate alarm line in / out terminals are provided. 4. Main body is pushed into sounder base and then twisted to lock into place. 5. Supply is common for sounder and beacon

Interface Options
MCD524SB / MCD524DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

- - - - + +
Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MCD524SB MCD524DB Description Conventional low profile xenon sounder beacon Conventional weatherproof xenon sounder beacon

40

Conventional Product Range

LED Beacons MLB124SB and MLB124DB

MLB124DB weatherproof LED beacon

MLB124SB low profile LED beacon

Overview
This range of Menvier LED beacons is available to complement audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. low profile base MLB124SB The MLB124SB low profile LED beacon is simple to install, and offers a reduced depth with pre-drilled fixing and cable entry holes, suitable for both wall or ceiling mounting. This beacon utilises 18 carefully positioned LED's to provide a high intensity output. Both output intensity and flash frequency is selectable using internal DIP switch. MLB124DB The MLB124DB weatherproof LED beacon is IP65 rated making them ideal for industrial applications. This beacon utilises 18 carefully positioned LED's to provide a high intensity output. Both output intensity and flash frequency is selectable using internal DIP switch.

Features
MLB124SB Unobtrusive low profile design Low power consumption LEDs Choice of flash frequency Choice of power settings Pre drilled cable entries MLB124DB Weatherproof version (IP65) Low power consumption LEDs Choice of flash frequency Choice of power settings Choice of cable entry positions

Benefits
Low power requirement Selectable flash frequency Selectable flash intensity

weatherproof base

41

Conventional LED Beacons - MLB124SB and MLB124DB

Dimensions

Technical Specification
Code Description Specification
D

MLB124SB Low profile LED beacon

MLB124DB Weatherproof LED beacon

Operating Voltage Current Consumption Flash Frequency Environmental Operating Temperature

18V dc to 30V dc 3 to 6mA at 24V dc (depending on power setting) 30 or 60 per minute (selectable)

18V dc to 30V dc 3 to 6mA at 24V dc (depending on power setting) 30 or 60 per minute (selectable)

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

Dia

Dia

Humidity (Non Condensing) Physical

Low profile LED beacon Description Low profile LED beacon Weatherproof LED beacon

Weatherproof LED beacon Dia (mm) 95 95 D (mm) 53 80

Construction Colour Lens Colour Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

PC/ABS Red Red 95mm x 53mm 0.1kg IP54 Rear

PC/ABS Red Red 95mm x 80mm 0.15kg IP65 Rear/side

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MLB124SB / MLB124DB + + Compatible Menvier Conventional Control Panel

Installation
MLB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into base and then twisted to lock into place. MLB124DB 1. Supplied with simple to install first fix mounting base. 2. Cable entry is from rear or side. 3. Connections are to main beacon body. 4. Separate alarm line in / out terminals are provided. 5. Main body is pushed into base and then twisted to lock into place.

Interface Options
MLB124SB / MLB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable

Product Codes
Code MLB124SB MLB124DB Description Conventional low profile LED beacon Conventional weatherproof LED beacon

42

Conventional Product Range

LED Sounder Beacon MSB124SB and MSB124DB

MSB124DB weatherproof LED sounder beacon

MSB124SB low profile LED sounder beacon

Overview
This range of Menvier LED sounder beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. MSB124SB The MSB124SB low profile LED sounder beacon features a low current LED light source and adjustable volume control. Choice of tones can be selected via the DIP switch. With predrilled fixing and cable entry holes it is simple to install. MSB124DB The MSB124DB weatherproof LED sounder beacon is IP65 rated and features a low current LED light source and adjustable volume control.

Features
MSB124SB Unobtrusive low profile design Low current LED beacon Sounder and beacon with a single installation point Pre-drilled fixing and cable entry holes 32 selectable tones MSB124DB Weatherproof version (IP65) Low current LED beacon Sounder and beacon with a single installation point Choice of cable entry positions 32 selectable tones

low profile base

Benefits
Low power requirement Adjustable sounder volume Selectable tones

weatherproof base

43

Conventional LED Sounder Beacon - MSB124SB and MSB124DB

Dimensions
Dia
Dia

Technical Specification
Code Description Standards Specification Operating Voltage 9V dc to 28V dc 20mA at tone 3 Continuous 60 per minute 32 9V dc to 28V dc 20mA at tone 3 Continuous 60 per minute 32 MSB124SB Low profile LED sounder beacon EN54 Pt3 MSB124DB Weatherproof LED sounder beacon EN54 Pt3

Current Consumption Operation Flash Frequency Number of Tones Environmental

Low profile LED sounder beacon Description Low profile LED sounder beacon Weatherproof LED sounder beacon

Weatherproof LED sounder beacon Dia (mm) 93 95 D (mm) 80 109

Operating Temperature Humidity (Non Condensing) Physical Construction Colour Lens Colour Dimensions (Dia x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

PC/ABS Red Red 93mm x 80mm 0.25kg IP54 Rear

PC/ABS Red Red 95mm x 109mm 0.3kg IP65 Rear/side

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MSB124SB / MSB124DB
2nd SOUND 1st SOUND COMMON

Installation
MSB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. 7. Supply is common for sounder and beacon MSB124DB 1. Cable entry is from rear or side. 2. Connections are to main beacon body. 3. Separate alarm line in / out terminals are provided. 4. Main body is pushed into base and then twisted to lock into place. 5. Supply is common for sounder and beacon

Interface Options
MSB124SB / MSB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. .

+ + - - - Compatible Menvier Conventional Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal.

Product Codes
Code MSB124SB MSB124DB Description Conventional low profile LED sounder beacon Conventional weatherproof LED sounder beacon

44

Conventional Product Range

Heavy Duty Door Retainers MDR240 and MDR24L

floor mounted heavy duty door retainer

wall mounted heavy duty door retainer

Overview
door strike plate This range of Menvier heavy duty magnetic door retainers are robust and simple to install, making them ideal for a wide range of applications, such as nursing homes, hospitals, schools and industrial premises. Two versions are available, the mains powered MDR240 which has a holding force of 40kg and the MDR24L 24V dc powered also with a holding force of 40kg Both versions enable doors to be held open under normal conditions but to be automatically released in the event of fire alarm activation. Their die cast aluminium construction with plastic front cover plate make them suitable for most applications. Both versions are supplied with door mounted striker plates and can be fixed directly to a suitable wall, alternatively a floor bracket can be used to allow floor mounting. An override switch is fitted as standard to enable door to be manually released as required.

Features
Heavy duty construction Mains and 24V dc version Manual release switch Optional floor mounting bracket available

Benefits
Quick and simple to install Slim profile unit

45

Conventional Heavy Duty Door Retainers - MDR240 and MDR24L

Dimensions
D W D W

Technical Specification
Code Description Specification Operating Voltage Power Consumption 230V ac to 240V ac 1.2VA 40kg 24V dc 40mA 40kg MDR240 Mains powered heavy duty door retainer MDR24L 24V dc powered heavy duty door retainer

H H

Holding Force Environmental Operating Temperature Humidity (Non Condensing) Physical Construction

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

PC/ABS White body / black plate Magnet: 95mm x 95mm 40mm Striker plate: 65mm x 65mm x 48mm

PC/ABS White body / black plate Magnet: 95mm x 95mm 40mm Striker plate: 65mm x 65mm x 48mm 1.0kg IP40

Description Magnet Striker Plate

H (mm) 95 65

W (mm) 95 65

D (mm) 40 48

Colour Dimensions (H x W x D)

Weight Ingress Protection Compatibility Suitable for use with

1.0kg IP40

Menvier conventional fire systems

Menvier conventional fire systems

Standard Connection
MDR240 / MDR24L
INPUT VOLTAGE

Installation
1. Door retainer unit and striker plate should be fixed to a smooth surface. 2. A single 20mm cable entry facility is provided. 3. Door retainer can be rotated to provide cable entry at either top, bottom or side as required. 4. Fixings should be able to support at least double the holding force of the magnet.

System Functionality
1. Designed to operate only with self closing doors. 2. Door retainer is fitted to wall or floor using floor bracket. 3. Striker plate is fitted to door. 4. Door retainer is fed with a constant supply via an external control device. 5. Supply energises an electromagnet, which holds the striker plate securely against the magnet. 6. If supply to magnet is interrupted, magnet deenergises. 7. Door closes under control of its own self closing device.

TO HEAVY DUTY DOOR MAGNET WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Product Codes
Code MDR240 MDR24L ZMDRFBB Description Conventional mains powered heavy duty magnetic door retainer Conventional 24V dc heavy duty magnetic door retainer Floor mounting bracket for heavy duty door retainer

46

Intelligent Addressable Product Range

Intelligent Addressable Contents


Page 49 Control Panels DF6100 Page 77 Callpoints MBG813 and MBG817

Page 55 Control Panels DF6000

Page 79 Wall Sounders MAS850LPS and MAS850LPSWP

Page 61 Passive Repeater Panel DF6000PR

Page 81 Wall Sounder Beacons MASB860 and MASB860WP

Page 63 Touch Screen Repeater Panel DTPR6000

Page 83 Loop Connected LED Beacon MAB870

Page 65 Sensors MAP820, MAOH850 and MAH830

Page 85 Interfaces

Page 67 Standard Base MAB800

Page 97 Micro Interfaces

Page 69 Sounder Base MAS850

Page 103 Ancillaries and Test Equipment

Page 71 Sounder Beacon Base MASB870

Page 73 Loop Connected Remote Indicator MRIAD

Page 75 Reflective Beam Detectors MAB50R and MAB100R

47

Intelligent Addressable Product Range

Intelligent Addressable System Architecture


Standard conventional systems utilise simple two state detectors, which simply provide a switch type signal to the conventional control panel. To enable the source of the alarm to be identified, each zone must be wired using a separate circuit, furthermore in the event of a fire alarm being triggered, the panel can only identify which zone contains the triggered device, it is then necessary to manually search the affected zone to discover the actual cause of the alarm. Intelligent addressable systems overcome these limitations, each fire detecting sensor or callpoint is electronically coded with a unique identification or 'address' which is programmed into the device during installation. The control panel is then able to conduct two way communication with any of the addressable devices connected to the system by using the unique address number to define which device it wishes to communicate with. This operates in a similar manner to that of a telephone number enabling communication between specific telephones. Under normal conditions the control panel continuously interrogates each device in sequence using a low power digitally pulsed signal, and analyses the reply to determine the status of the sensor or callpoint. In this manner, the panel can ascertain whether each device is functioning correctly and also discover the amount of smoke or heat that the device is currently sensing. This technology allows the panel to make intelligent decisions as to the appropriate action to take based on the information it receives from the individual sensors. This has many advantages, for example very slow build up of apparent smoke density seen by a sensor can cause a warning or pre alarm condition to be triggered by the alarm panel prior to the situation becoming serious enough to warrant a full alarm. A typical practical benefit of this technology is the situation whereby airborne dust particles enter smoke detectors and mimic the appearance of smoke, over time the concentration of dust can increase to a point where it can cause the detector to falsely trigger an alarm condition. With an intelligent addressable system, a pre alarm condition will normally be triggered rather than a full alarm giving the building operator the opportunity to clean or replace the sensor rather than suffer the disruption of an unwanted false alarm. If whilst continually interrogating the smoke and heat sensors, the panel determines that the data gathered from a specific device is appropriate to instigate either a fire, fault or pre alarm condition, it uses the unique identifying number or address to determine which device is involved. Consequently the panel can pinpoint and identify precisely which device has triggered the fire, fault or pre alarm condition. This level of sophistication removes the need for each zone of the building to be wired as a separate circuit. For this reason intelligent addressable system components are typically connected to the panel using a small number of large loops thus greatly simplifying the installation of the system and reducing the installation cost. Detectors instead of being simple two state devices now function as sensors continually communicating with the control panel and providing information regarding the temperature or concentration of smoke in their local environment.

Zone 1

Zone 2

15 14

16

2 3

13

Mains Supply 12 5

11

10

Zone 3

Zone 4

48

Intelligent Addressable Product Range

DF6100 Control Panels

DF6100 control panel, interior

DF6100 control panel

Overview
The Menvier DF6100 range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation. The simplicity of operation, powerful cause and effect programming capability, and competitive pricing make the system suitable for a wide range of small to medium sized projects. DF6100 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. These panels can operate as a stand alone panel or as part of a network with the Menvier range of DF6000 panels or other DF6100 panels, (additional network card required). The DF6100 panel has an integral power supply and is supplied with batteries as standard. An extensive range of compatible intelligent addressable system ancillaries are available to work with the DF6100 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the loop.

Features
Large versatile touch screen display Competitive single or two loop system Spur tolerant soft addressing Large selection of compatible ancillaries Full network capability Integral battery and power supply 200 address capacity per loop Approved to EN54 Pt13 and EN54 Pt2 and Pt4

Benefits
Simple end user interface Range of compatible ancillaries System protocol allows fast and accurate configuration

49

Intelligent Addressable Control Panel - DF6100 and DF61002

Technical Specification
Code Description Standards DF6100 1 loop control panel EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt13, EN50130-4 Specification Number of Loops Addresses per Loop Number of Conventional Sounder Circuits Auxiliary Fire Routing Equipment Output (Monitored) Auxiliary Fire Protection Equipment Output (Monitored) Auxiliary Fault Routing Equipment Output (Monitored) System Operating Voltage Mains Input Supply Class Change Facility 12V dc 30mA (max) 24V dc (nom) 230V ac +10% / -15% Terminals for connection of external contacts, can also be instigated via input interface Auxiliary Relay 1 set of changeover contacts operate in event of fire condition Output Ports Standby Duration Battery Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Cable entries System Networking Steel back box 375mm x 375mm x 95mm 8kg IP30 Top: cable knockouts (20mm) Back: cable aperture Fully Networkable up to 127 panels (requires additional network card, per panel) Steel back box 375mm x 375mm x 95mm 8kg IP30 Top: cable knockouts (20mm) Back: cable aperture Fully Networkable up to 127 panels (requires additional network card, per panel) -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH RS485, RS232 for connection of repeaters etc Dependant on loop loading and battery configuration 2 x 7Ah 12V dc 30mA (max) 24V dc (nom) 230V ac +10% / -15% Terminals for connection of external contacts, can also be instigated via input interface 1 set of changeover contacts operate in event of fire condition RS485, RS232 for connection of repeaters etc Dependant on loop loading and battery configuration 2 x 7Ah 24V dc 30mA (max) 24V dc 30mA (max) 24V dc 30mA (max) 24V dc 30mA (max) 1 200 2 monitored for open and short circuit (max 1.5A combined) 2 200 2 monitored for open and short circuit (max 1.5A combined) DF61002 2 loop control panel EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt13, EN50130-4

Dimensions
D W

H (mm) W (mm) D (mm) 375 375 95

Product Codes
Code DF6100 DF61002 NC DF61NETKIT DF6000PR DTPR6000 MFALOG Description Intelligent addressable 1 loop control panel Intelligent addressable 2 loop control panel Add to end of product code if network card required Network kit (retro fit) Passive repeater panel Touch screen repeater panel Fire alarm system log book

50

Intelligent Addressable Control Panel - DF6100 and DF61002

Installation
1. Panel is designed for surface or recessed mounting (without the need for an additional bezel). 2. Cable entry is by means of top entry knockouts in the metal back box, along with a substantial rear entry cutout. 3. Panels are wall mounted via keyhole/slot mounting holes on back of housing. 4. Key operated hinged lockable door provides access to all internal wiring. 5. Cable entry can either be top or rear. 6. Mains input protection is provided by integral fuse 7. All external wiring should be in accordance with relevant section of latest edition of BS5839-Pt1. 8. Comprehensive installation and operation manual provided with each system.

User Interface
1. The main element of the user interface with DF6100 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as a multifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated. 2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation. 3. The DF6100 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automatically formatted as a full QWERTY keyboard to enable fast and simple text entry. 4. As well as a large format LCD display providing full system status information, the panel incorporates 16 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users 5. Audible buzzer with mute facility. 6. Hinged lockable door provides access to all internal wiring and components.

Interface Options
Day night mode override via external switched signal. (Can be a timer). Multiple Programmable remote inputs can be set: Override of day night mode setting - Photo-thermal detectors go to thermal only. - Rate of rise detectors go to fixed high temperature mode. - High temperature heat detectors go to rate of rise mode. T1 and T2 timer. HMO facility. Comprehensive cause and effect programming. Test per zone or address. Alarm verification per zone. Coincidence detection. Disablement of pre assigned group of addresses. Class change. Non latching zone input. Evacuate. 2 Conventional sounder circuits provided. Zone monitor units can be used to connect zones of suitable conventional detectors or loop powered beam detectors. Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel. Mains rated input/output unit available. 3 way 24V rated input/output unit available. Spur isolator available to allow spurs of intelligent addressable devices. Compact input and output modules available Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel.

System Functionality
1. Panel has 3 modes of operation, normal mode, user maintenance mode and engineer mode. 2. User maintenance and engineer modes can only be accessed by entering relevant pass codes 3. Maintenance mode allows access to system test functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset. 4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming. 5. Engineer mode also allows adding and removal of devices and alteration of existing text. 6. DF6100 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6100 will allocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of as fitted drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use, the addresses of the remaining devices are not affected. 7. All devices are soft addressed during commissioning however once allocated, addresses are locked until manually altered thus enabling simple system additions and deletions without affecting other addresses. 8. In event of an external short circuit occurring, short circuit isolators on output of the devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices.

Detection Capacity
1. Up to 200 addresses per loop which can be a mixture of callpoints, detectors, interfaces or loop sounders. 2. DF6100 panels can be networked with all Cooper intelligent addressable and wireless panels.

Alarm Capacity
1. Up to 80 loop powered outputs per loop (60 sounders/beacons and 20 I/O units). 2. 3 stages of cause and effect programming per output device. 3. 0.8A of panel connected conventional sounders. 4. Additional conventional sounders can be connected via loop mounted MPU424 units.

51

Intelligent Addressable Control Panel - DF6100 and DF61002

System Networking
DF6000 and DF6100 systems can both be networked together. Up to 126 DF6000 panels, DF6100 panels and low cost repeaters can be networked together to operate as a single networked system. To achieve this each panel must be fitted with a network card (optional extra). When operating as a networked system all fire and fault event information can be displayed at every panel. Panels can be configured by service engineers to control whether fire and fault information from each panel is transmitted around the network or not. Silencing and resetting of alarms can also be carried out from any panel on a networked system. Networked panels are connected using a loop topology as illustrated.

Typical System Architecture


4 independently controlled conventional sounder circuits

spur of analogue devices

zone of compatible conventional devices

Mains Supply sounder controller unit

loop connected repeater panel

spur isolator unit

zone monitor unit

DF6100
3 independent volt free output contacts 3 way input/output unit 3 separate inputs to accept re or non re inputs mains rated output relay contact input/output unit

shop monitor unit

Mains Supply

Mains Supply

Mains Supply

Mains Supply

DF6000, DF6100 and DTPR6000

re or non re input

zone of compatible conventional devices control panel

2 circuits of conventional sounders

Mains Supply

Mains Supply

Mains Supply

Mains Supply

2 circuits of conventional sounders

network connected repeater panel

52

Intelligent Addressable Control Panel - DF6100 and DF61002

Standard Panel Connections


MENVIER CONVENTIONAL SOUNDERS (IF REQUIRIED)

}
SOUNDER SOUNDER CIRCUIT 1 CIRCUIT 2 FAULT RELAY

+ +
NO NO

6K8 EOL RESISTOR* 6K8 EOL RESISTOR*

AUX RELAY 1 C NC AUX RELAY 2 C NC

VOLT FREE CHANGE OVER CONTACT

VOLT FREE CHANGE OVER CONTACT

+ A E A E

FAULT RELAY

NETWORK 1 B X Y NETWORK 2 B X Y + 24V OUT

NETWORK 1

NETWORK 2

+
E S+ SE S+ SE E

24V dc OUTPUT

LOOP 1 F+ FLOOP 2 F+ F-

LOOP 1 CONNECTIONS

LOOP 2 CONNECTIONS (IF DF61002)

START LOOP TERMINALS

FINISH LOOP TERMINALS * required to be tted to terminal if circuits not used

53

Intelligent Addressable Product Range

54

Intelligent Addressable Product Range

DF6000 Range Control Panels

DF6000 control panel with printer

DF6000 graphite control panel with protective cover and printer

Overview
The Menvier DF6000 is a high specification intelligent addressable control panel available in various loop configurations. It combines sophisticated functionality with simple operation and a very aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments and industrial applications. DF6000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. The DF6000 can operate as a stand alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local. The DF6000 panel has integral power supply and batteries the batteries are supplied with the panel as standard. An extensive range of compatible intelligent addressable systems ancillaries are available to work with the DF6000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop.

Features
1, 2 and 4 loop versions Spur tolerant soft addressing Full network capability Optional integral printer Integral battery and power supply 200 addresses per loop Charger with temperature compensation built in Checks battery capacity

Benefits
Simple end user interface Range of compatible ancillaries Easy to design system System Integrity Battery life can be extended

rack mounted panels

55

Intelligent Addressable Control Panels - DF6000 Range

Technical Specification
Code Description Standards Specification Number of Loops Addresses per Loop Number of Conventional Sounder Circuits Auxiliary Fire Routing Equipment Output (Monitored) Auxiliary Fire Protection Equipment Output (Monitored) Auxiliary Fault Routing Equipment Output (Monitored) System Operating Voltage Mains Input Supply Class Change Facility 12V 30mA (max) 24V dc (nom) 230V ac +10% / -15% Terminals for connection of external contacts, can also be instigated via input interface Auxiliary Relay Output Ports Standby Duration Battery Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Dimensions (H x W x D) Back box - mild steel, front door - PC/ABS Standard versions: 395mm x 495mm x 180mm Back box - mild steel, front door - PC/ABS Standard versions: 395mm x 495mm x 180mm EB versions: 395mm x 495mm x 280mm Weight Ingress Protection Cable entries System Networking 18kg IP30 Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Fully networkable up to 126 panels (requires additional network card - 1 per panel) 18kg IP30 Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Fully networkable up to 126 panels (requires additional network card - 1 per panel) Back box - mild steel, front door - PC/ABS Standard versions: 395mm x 495mm x 180mm EB versions: 395mm x 495mm x 280mm 18kg IP30 Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Fully networkable up to 126 panels (requires additional network card - 1 per panel) -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH -5C to +40C 0 to 75% RH 1 set of changeover contacts operate in event of fire condition RS485, RS232 for connection of repeaters etc Dependant on loop loading and battery configuration 2 x 12Ah (standard versions) 12V 30mA (max) 24V dc (nom) 230V ac +10% / -15% Terminals for connection of external contacts, can also be instigated via input interface 1 set of changeover contacts operate in event of fire condition RS485, RS232 for connection of repeaters etc Dependant on loop loading and battery configuration 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) 12V 30mA (max) 24V dc (nom) 230V ac +10% / -15% Terminals for connection of external contacts, can also be instigated via input interface 1 set of changeover contacts operate in event of fire condition RS485, RS232 for connection of repeaters etc Dependant on loop loading and battery configuration 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) 4 monitored for open and short circuit 4 monitored for open and short circuit 4 monitored for open and short circuit 1 200 2 200 4 200 DF60001 1 loop control panel EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 DF60002 2 loop control panel EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 DF60004 4 loop control panel EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4

Dimensions
D2 W

Product Codes
Code DF60001 DF60002 DF60004 DF60001P DF60002P DF60004P DF60001G DF60002G DF60004G DF60001PG DF60002PG DF60004PG DF60002EB DF60004EB DF60002PEB DF60004PEB DF60002GEB DF60004GEB DF60002PGEB DF60004PGEB NC DF6000NETKIT DF6000COV DF6000PR DTPR6000 39UECRACK MFALOG Description 1 loop control panel 2 loop control panel 4 loop control panel 1 loop control panel, integral printer 2 loop control panel, integral printer 4 loop control panel, integral printer 1 loop control panel, graphite finish 2 loop control panel, graphite finish 4 loop control panel, graphite finish 1 loop control panel, integral printer, graphite finish 2 loop control panel, integral printer, graphite finish 4 loop control panel, integral printer, graphite finish 2 loop control panel, extended battery 4 loop control panel, extended battery 2 loop control panel, integral printer, extended battery 4 loop control panel, integral printer, extended battery 2 loop control panel, graphite finish, extended battery 4 loop control panel, graphite finish, extended battery 2 loop control panel, graphite finish, integral printer, extended battery 4 loop control panel, graphite finish, integral printer, extended battery Add to end of product code if network card required Network kit (for retor fit) Hinged protective cover kit Passive repeater panel Touch screen repeater panel 19" rack, 39 units high* Fire alarm system log book

D1

Description H (mm) W (mm) D1 (mm) D2 (mm) Standard 395 495 55 125 EB 395 495 55 225 Note: If surface mounting add D1 and D2 to obtain depth dimension.

* For further information on the 39UERACK 19" rack and associated panels contact Cooper Fire technical support: 01302 303350

56

Intelligent Addressable Control Panels - DF6000 Range

Installation
1. Standard panel is designed for surface or recessed mounting (without the need for an additional bezel). 2. Cable entry is by means of top entry knockouts in the metal back box, along with a substantial rear entry cutout. 3. Panels are wall mounted via keyhole/slot mounting holes on back of housing. 4. Front cover retained by screws, accessed after opening the printer bay door. 5. Flush mounting requires suitable aperture and fixings. 6. Mains input protection is provided by a polyswitch. 7. All external wiring should be in accordance with relevant section of latest edition of BS5839-Pt1. 8. Comprehensive installation and operation manual provided with each system. 9. Maximum length of network cable loop is 1500 metres, beyond this distance or where cables pass between buildings, boosters will be required.

User Interface
1. The main element of the user interface with DF6000 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as a multifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated. 2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation. 3. The DF6000 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automatically formatted as a full QWERTY keyboard to enable fast and simple text entry. 4. As well as a large format LCD display providing full system status information, the panel incorporates 96 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users 5. Access to printer (when fitted) is via separate locked access door. Paper can be changed by non skilled personnel without exposure to any live components. 6. The printer can either be set to print on demand or to automatically print all system events as they occur. 7. The hinged front door provides simple access to all internal components and wiring. 8. The panel door cannot be opened without the use of a special key (supplied with panel). 9. For applications requiring a high level of resilience, a clear hinged lockable front cover is available that still allows full system visibility but prevents unauthorized access to the touch screen.

Interface Options
Monitored output to fire routing equipment. Monitored output to fire protection equipment. Monitored output to fault monitoring equipment. Multiple Programmable remote inputs can be set: Override of day night mode setting - Photo-thermal detectors go to thermal only. - Rate of rise detectors go to fixed high temperature mode. - High temperature heat detectors go to rate of rise mode. Disablement of pre assigned group of addresses. Class change. Non latching zone input. Evacuate. 4 Conventional sounder circuits provided. Zone monitor units can be used to connect zones of suitable conventional detectors and callpoints. Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel. Mains rated input/output unit available. 3 way 24V rated input/output unit available. Spur isolator available to allow spurs of intelligent addressable devices. Compact input and output modules available Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel.

System Functionality
1. Panel has 3 modes of operation, normal mode, user maintenance mode and engineer mode. 2. User maintenance and engineer modes can only be accessed by entering relevant pass codes 3. Maintenance mode allows access to system test functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset. 4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming. 5. Engineer mode also allows adding and removal of devices and alteration of existing text. 6. DF6000 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6000 will allocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of as fitted drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use, the addresses of the remaining devices are not affected. 7. All devices are soft addressed during commissioning however once allocated, addresses are locked until manually altered thus enabling simple system additions and deletions without affecting other addresses. 8. In event of an external short circuit occurring, short circuit isolators on output of devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices.

Detection Capacity
1. Up to 200 addresses per loop which can be a mixture of callpoints, detectors, interfaces loop sounders or repeaters. 2. To comply with EN54 requirements no more than 512 addresses should be connected to a single panel. 3. Panels are available with up to 4 detection loops, up to 126 panels can be networked together giving a total system capacity of over 32,000 devices.

Alarm Capacity
1. Up to 80 loop powered outputs per loop (60 sounders/beacons and 20 I/O units). 2. 3 stages of cause and effect programming per output device. 3. Depending on loop load up to 3A of panel connected conventional sounders. 4. Additional conventional sounders can be connected via loop connected MPU424 units.

57

Intelligent Addressable Control Panels - DF6000 Range

System Networking
DF6000 and DF6100 systems can both be networked together. Up to 126 DF6000 panels, DF6100 panels and low cost repeaters can be networked together to operate as a single networked system. To achieve this each panel must be fitted with a network card (optional extra). When operating as a networked system all fire and fault event information can be displayed at every panel. Panels can be configured by service engineers to control whether fire and fault information from each panel is transmitted around the network or not. Silencing and resetting of alarms can also be carried out from any panel on a networked system. Networked panels are connected using a loop topology as illustrated.

Typical System Architecture


4 independently controlled conventional sounder circuits

spur of analogue devices loops 2-4 if tted

zone of compatible conventional devices

Mains Supply sounder controller unit

loop connected repeater panel

spur isolator unit

zone monitor unit

Networking DF6000
3 independent volt free output contacts 3 way input/output unit 3 separate inputs to accept re or non re inputs

shop monitor unit

Mains Supply

Mains Supply

Mains Supply

Mains Supply

mains rated output relay contact input/output unit

DF6000, DF6100 and DTPR6000

re or non re input

zone of compatible conventional devices control panel

2 circuits of conventional sounders

Mains Supply

Mains Supply

Mains Supply

Mains Supply

2 circuits of conventional sounders

network connected repeater panel

58

Intelligent Addressable Control Panels - DF6000 Range

Standard Panel Connections


+5.5V SUPPLY FOR PRINTER (IF FITTED)

NO

AUX RELAY FAULT RELAY +24V O/P FIRE R/E FIRE P/E LOOP 1 LOOP 2 LOOP 3 LOOP 4 CLASS CHANGE SOUNDER CIRCUIT 1 SOUNDER CIRCUIT 2 MODEM/PC Rs232 MIMC REPEATER LOOP CIRCUITS

C NC

VOLT FREE CHANGE OVER CONTACT

- + - + + - +
S+ SFF+ S+ SFF+ S+ SFF+ S+ SFF+

6K8 EOL RESISTOR*

6K8 EOL RESISTOR* 6K8 EOL RESISTOR* START LOOP 1 FINISH LOOP 1 START LOOP 2 FINISH LOOP 2

START LOOP 3 FINISH LOOP 3 START LOOP 4 FINISH LOOP 4 CLASS CHANGE INPUT IF REQUIRED

- + +
1-

+
2-

+
1-

+ 6K8 EOL RESISTOR*


2-

}
MENVIER CONVENTIONAL SOUNDERS (IF REQUIRED) * required to be tted to terminal if circuits not used

Tx Rx CTS RTS 0V Tx+ Tx-

59

Intelligent Addressable Product Range

60

Intelligent Addressable Product Range

Passive Repeater Panel DF6000PR

simple user interface

DF6000PR passive repeater panel

Overview
The DF6000PR is a cost effective passive repeater panel which can be programmed via its informative display to be either fully passive (display only) or semi passive (restricted system control). When loop connected the repeater panel will display the system information text of the connected control panel and will provide a fire indication, with panel number, of any connected network control panel that has fire activation. The DF6000PR repeater panel only requires programming with local text information. In addition to the repeater panels main menu driven 2 x 40 backlit LCD display, which provides system status information, it also has 6 supervisory LEDs (Power On, Alarm, Trouble, Supervisory, Test In Progress, and Scroll).

Features
Up to 20 repeaters can be connected to the loop 2 x 40 backlit LCD display and 6 supervisory LEDs Compact size Can be surface or semirecessed mounted

Benefits
Menu driven easy to operate Simple connection to panel loop circuit reduces wiring and installation time Distance run up to 2km from main panel without additional cable and equipment, saving cost

2 x 40 backlit LCD display and 6 supervisory LEDs

61

Intelligent Addressable Passive Repeater Panel - DF6000PR

Dimensions
D1 W

Technical Specification
Code Description Standards Specification Mains Input Voltage 230V ac +10% / -15% 24V dc Power on, fire, fault, test, disable and scroll Silence alarms, evacuate and reset RS232 (for connection of programmer) 1 x 12V 3.2Ah 24 hours CF30000PR Passive repeater panel EN54 Pt4

MUTE BUZZER

SCROLL

Operating Voltage System Indicators System Controls Input Ports

D2

Battery Standby Duration Environmental

H (mm) 270

W (mm) 332

D1 (mm) 45

D2 (mm) 47

Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

0C to +25C 0 to 75% RH

PC/ABS Light Grey 332mm x 270mm x 92mm 3.6kg IP30

Menvier intelligent addressable fire systems

Loop Connected

Installation
1. Wall mounted by means of 4 fixing screws. 2. Cable entry at top or back. 3. 12 top entry gland holes with push out blanking plugs. 4. 4 separate rear access cable entry facilities. 5. Local mains supply required.

6. When connected to a detector loop, text for host is downloaded to repeater and updated manually as required. 7. Zonal fire and fault indication is by means of 2 x 40 character LCD display.

Device Overview
Mains Supply

System Functionality
1. Panel operates in either normal, supervisor or engineer mode. 2. Supervisor and engineer modes are accessed via 4 digit pass codes. 3. Supervisor mode allows silence, evacuate and reset commands to be sent to host panel (loop connected) or to network (network connected). 4. Engineer mode enables password to be changed if required and allows access to text download menu 5. When connected to network, all text is transmitted via network, changes to other network panels update automatically.

Mains Supply

Network Link

Note:

In this configuration the repeater would give text information for the panel that is on the loop, but only address number for the other panel on the network.

1. Panel can be connected to either the detection loop of a single panel or to a network as part of a networked system. 2. Supplied with integral power supply and standby battery.

Network Connected

Standard Connection
SCREEN Tx + Tx SCREEN
Rs485 MIMIC LOOP OUT

SCREEN

LOOP IN

TEXT DOWNLOAD

- +

- +

Mains Supply

Network Link

Product Codes
Code DF6000PR DF6000PRNC Description Intelligent addressable passive repeater panel, loop connected Intelligent addressable passive repeater panel, network connected

62

Intelligent Addressable Product Range

Touch Screen Repeater Panel DTPR6000

DTPR6000 touch screen repeater panel

Overview
The DTPR6000 touch screen repeater panel provides sophisticated touch screen functionality yet achieves a simple end-user interface operation within a compact panel design. The DTPR6000 is designed to work with all Menvier intelligent addressable fire alarm control panels as well as other network repeaters. The Menvier touch-screen repeater panel is easy to install and commission. All text is transmitted via the network and is automatically updated.

Features
Plug and play. All information is downloaded through the network Touch-screen display Integrated network capability allows networking with the latest Menvier range of intelligent addressable fire alarm control panels Multi language capability Up to 126 repeaters can be connected to the network Programmable as an active or passive repeater

Benefits
Plug and play requires no programming User friendly touch screen display System integrity, fire alarm system continues to operate even if there is a short circuit or open joint on cable Multi language capability

63

Touch Screen Repeater Panel - DTPR6000

Dimensions
D W

Technical Specification
Code Description Standards Specification Mains Input Voltage 230V ac +10% / -15% 24V dc DTPR6000 Touch screen repeater panel EN54 Pt4

Operating Voltage

System Indicators System Controls Input Ports Battery Standby Duration

Power on, fire, fault, test, disable and scroll Silence alarms, evacuate and reset RS232 (for connection of programmer) 2 x 12V 3.2Ah 24 hours

H (mm) 375

W (mm) 537

D1 (mm) 50

Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with Menvier intelligent addressable fire systems PC/ABS Graphite 375mm x 357mm x 50mm 8kg IP30 -5C to +40C 0 to 75% RH

Network Connected

Installation
Wall mounted by means of 4 fixing screws. Cable entry at top or back. 11 top entry gland holes. Separate rear access cable entry facility. Local mains supply required. Must be network connected.

Device Overview
Panel is connected to the network as part of a networked system. Supplied with integral power supply and standby battery. Touch screen user interface.

System Functionality
Mains Supply

Network Link

Panel operates in either normal, supervisor or engineer mode. Supervisor and engineer modes are accessed via 4 digit pass codes. Supervisor mode allows full system operation. Engineer mode enables password to be changed if required and allows access to text download menu When connected to network, all text is transmitted via network, changes to other network panels update automatically.

Standard Connection
+24V dc IN +24V dc OUT NETWORK 1 NETWORK 2 FAULT RELAY AUX RELAY
PROGRAMMABLE INPUT

+ -

+ -

A B X Y E

A B X Y E

NO C NC NO C NC

TO PANEL EARTH

Product Codes
Code DTPR6000 Description Intelligent addressable touch screen repeater panel

64

Intelligent Addressable Product Range

Sensors MAP820, MAOH850 and MAH830

MAP820 optical sensor

MAOH850 photo-thermal sensor

optical / photo-thermal / heat detectors

Overview
The Menvier range of intelligent addressable sensors have been specifically designed to operate with Menvier intelligent addressable control panels. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors).

Features
Soft addressed Integral short circuit isolator Wide range of sensor types 360 visibility LED

Benefits
Single multi-mode heat sensor

MAH830 heat sensor

65

Intelligent Addressable Sensors - MAP820, MAOH850 and MAH830

Technical Specification
Code Description Standards Operating voltage Standby Current Alarm Current Addressing Mode Specification Mounting Position Mounting Options Area Coverage System Wiring Heat Class Rate of Rise Fixed Heat 77C Fixed Heat 90C Alarm Temperature (static) AIR BS CS Indication Environmental Operating Temperature Humidity (non condensing) Physical Construction Colour Dimensions Excl Base (Dia x D) Dimensions Incl Base (Dia x D) Weight (without base) Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems PC/ABS White 101mm x 33mm 104mm x 45mm 76g PC/ABS White 101mm x 43mm 104mm x 55mm 76g PC/ABS White 101mm x 43mm 104mm x 55mm 76g -20C to +60C 0 to 95% RH -20C to +50C 0 to 95% RH -20C to +60C 0 to 95% RH N/A N/A N/A 360 visibility light pipe 60C N/A N/A 360 visibility light pipe 60C 77C 90C 360 visibility light pipe N/A N/A N/A A1S N/A N/A A1R BS CS Ceiling in open areas Surface mount with MAB800 base 100m (subject to local standard) Min. 1.5mm, 2 core loop or spur Ceiling in open areas Surface mount with MAB800 base 100m (subject to local standard) Min. 1.5mm, 2 core loop or spur Ceiling in open areas Surface mount with MAB800 base 50m (subject to local standard) Min. 1.5mm, 2 core loop or spur MAP820 Optical smoke sensor EN54 Pt7 2000 + A1:2002 18V dc to 30V dc 220A (max) 5mA (max) Auto address MAOH850 Photo-thermal sensor EN54 P5 & P7 2000 + A1:2002 18V dc to 30V dc 220A (max) 5mA (max) Auto address MAH830 Multi-mode heat sensor EN54 Pt5 2000 + A1:2002 18V dc to 30V dc 220A (max) 5mA (max) Auto address

Dimensions
Dia

Installation
1. Sensors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised sensor removal without the use of a special tool. Note: For wiring information please see MAB800 base

User Interface
1. LED indicates detector status, can be set to flash to confirm communication with control panel, illuminates continuously under fire conditions. 2. All wiring connections are via a common mounting base (ordered separately).

Description Optical Photo-thermal Multi-mode heat

Dia (mm) 101 101 101

D (mm) D (mm) (excl base) (incl base) 33 45 43 55 43 55

Product Codes
Code MAP820 MAOH850 MAH830 MAB800 MAB800*10 MDP201 Description Intelligent addressable optical smoke sensor Intelligent addressable photo/thermal sensor Intelligent addressable multi-mode heat sensor Intelligent addressable common base Intelligent addressable common base (pack of 10) Duct Probe

66

Intelligent Addressable Product Range

Standard Base MAB800


Suitable sensors for use with the MAB800 standard base

MAP820 optical sensor

MAB800 standard base

Overview
MAOH850 photo-thermal sensor The MAB800 Menvier intelligent addressable standard base has been specifically designed to be compatible with Menvier intelligent addressable sensors. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates a purpose designed shorting link to ensure wiring continuity if a sensor is removed. The standard base incorporates a retaining clip to provide positive feedback when sensor is correctly fitted and a retaining clip that can be replaced with locking device (supplied with base) to prevent unauthorised sensor removal.

Features
Sensor shorting link Separate loop in and loop out terminals Stand off fixing feature Accepts side entry cables Selectable sensor locking feature

Benefits
Quick and simple to install Accepts side entry surface cables Common base for Menvier intelligent addressable sensors

MAH830 multi-mode heat sensor

67

Intelligent Addressable Standard Base - MAB800

Dimensions
Dia (mm) 104
D

Technical Specification
D (mm) 22
Code Description Physical Construction Colour Dimensions (Dia x D) Compatibility Suitable for use with Menvier intelligent addressable sensors PC/ABS White 104mm x 22mm MAB800 Standard base

Dia

Installation
1. Separate terminals are provided for loop in and loop out connections. 2. Each terminal can accept up to 2 x 2.5mm cables. 3. Base incorporates a substantial cable entry aperture in the rear of the base. 4. Breakouts are provided to enable the sensor base to sit neatly over surface cables and then enter via the rear entry aperture. 5. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 6. Fixings are suitable for standard BESA box or direct fixing to suitable surface.

User Interface
1. Heavy duty terminals are provided for each connection, each terminal can accept 2 x 2.5mm cables. 2. Separate loop in and loop out terminals are provided for each connection.

Standard Connection
+
remote indicator (optional)

+V
Compatible Menvier Intelligent Addressable Control Panel
Loop start

S+
LED

E
LED

4 3

E 3

S-

Loop nish

F-

F+

1 2

1 2

- VE OUT - VE IN
earth screen of cable must be continuous

WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact Ensure that cable or end of line resistor leg does not short onto the contact.

Product Codes
Code MAB800 Description Intelligent addressable standard base

68

Intelligent Addressable Product Range

Sounder Base MAS850

MAS850 with cover fitted

MAS850 sounder base

Overview
The intelligent addressable Menvier sounder base has been developed specifically to operate with the latest generation of Menvier intelligent addressable panels and to complement the latest generation of Menvier intelligent addressable sensors. The MAS850 sounder base incorporates a sensor mounting base, a sensor can be fitted to the sounder base or alternatively an optional cover plate can be used to enable the sounder to operate as a dedicated discreet stand alone sounder.

Features
Integral sensor mounting base Can be used with a sensor as a sounder base or stand alone sounder Optional cover plate available

MAS850 incorporates standard detector base

Benefits
First fix base Selectable tones controlled by the panel Adjustable volume controlled by the panel

69

Intelligent Addressable Sounder Base - MAS850

Dimensions
Dia (mm) 102
D

Technical Specification
Code MAS850 Sounder base EN54 Pt3

D (mm) 40

Description Standards Specification Operating Voltage Standby Current Tones (set by panel)

17V dc to 32V dc < 320A Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz @ 1Hz cycle

Dia

Slow whoop Sound Output @ +/-3dB (set by panel) Low volume : 84dB at <4mA Medium volume : 92dB at <8mA High volume : 95dB @ <12mA Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (Dia x D) Weight Ingress Protection Compatibility Suitable for use with Menvier intelligent addressable fire systems PC/ABS White 120mm x 40mm 0.2kg IP40 -10 to +55C 0 to 95% RH

Installation
1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only) 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Cables pass through aperture in sounder body and terminate at the front. 6. Connections are to connector block on front of main sounder body.

7. Sensor or cover plate is then fixed to sounder. 8. Sensor or cover plate can be locked in place if required.

System Functionality
1. Volume and tone are set by control panel, no need to access sounder to alter setting. 2. Soft addressed.

Standard Connection
3 Compatible Menvier Intelligent Addressable Control Panel
Loop start

3 2 4
LED

S+ S4
F-

Loop nish

F+

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop. NOTE: Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Product Codes
Code MAS850 MASC Description Intelligent addressable sounder base Sounder cover plates (pack of 5)

70

+ - + 1

+ - + LED

Intelligent Addressable Product Range

Sounder Beacon Base MASB870

MASB870 sounder beacon base

MASB870 with sensor fitted

Overview
The intelligent addressable Menvier sounder beacon base has been developed specifically to operate with the latest generation of Menvier intelligent addressable panels and Menvier sensors. The MASB870 sounder beacon base includes all the features of the intelligent addressable sounder base as well as a powerful LED beacon. The intelligent addressable beacon base incorporates a detector mounting base, a sensor can be fitted directly to the base, or alternatively an optional cover plate can be used to provide a dedicated discreet stand alone device.

Features
Integral sounder base Integral high output LED beacon Integral sensor mounting base Can be used with a sensor or stand alone Selectable tones controlled by the panel Adjustable volume controlled by the panel Optional cover plate available

Benefits
Saves time and installation costs Single point connection for sensor, sounder and LED strobe

71

Intelligent Addressable Sounder Beacon Base - MASB870

Dimensions
Dia

Technical Specification
Code MASB870 Sounder beacon base EN54 Pt3

Dia (mm) 115

D (mm) 44

Description Standards Specification Operating Voltage

17V dc to 32V dc < 320A Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz @ 1Hz cycle Slow whoop: 500 1200Hz in 3.5 Seconds

Standby Current Tones (set by panel)

Sound Output at +/-3dB (set by panel)

Low volume : 77dB at <6.6mA Medium volume : 89dB at <8mA High volume : 90dB @ <9mA

Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (Dia x D) Weight Ingress Protection Compatibility Suitable for use with Menvier intelligent addressable fire systems PC/ABS White 115mm x 44mm 0.2kg IP40 -10 to +55C 0 to 95% RH

Installation
1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only) 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Connections are to connector block on front of main sounder body. 6. Sensor or cover plate is then fixed to sounder, (can be locked in place if required).

System Functionality
1. Volume and tone are set by control panel, no need to access sounder to alter setting. 2. Soft addressed.

Standard Connection
3 Compatible Menvier Intelligent Addressable Control Panel
Loop start

3 2 4
LED

S+ S4
F-

Loop nish

F+

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop. NOTE: Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above.

Product Codes
Code MASB870 MASC Description Intelligent addressable sounder beacon base Sounder beacon cover plates (pack of 5)

72

+ - + 1

+ - + LED

Intelligent Addressable Product Range

Loop Connected Remote Indicator MRIAD

MRIAD loop connected remote indicator

Overview
The MRIAD intelligent addressable loop connected remote indicator is designed to provide discreet remote indication, which is controlled by the intelligent addressable fire panel, whilst providing the ability to monitor multiple detectors within an area thereby minimising wiring requirements. The unit is connected directly on the loop, is soft addressed by the panel on system start up and is fitted with integral short circuit isolators. When using Site installer the MRIAD should be programmed as an address output (sounder) and can be programmed using the comprehensive cause and effect tables to operate continuous, pulsing, by global, panel, zone, address or on double knock input etc. The unit is supplied complete with back box and is surface mounted.

Features
Simple to install Fits onto standard single gang back box Wide viewing angle high brightness LED Attractive styling

Benefits
Can be remote mounted Controlled by the panel Can be activated by cause and effect Reduced cost Minimises cabling

73

Intelligent Addressable Remote Indicator - MRIAD

Dimensions
D

Technical Specification
H (mm) W (mm) D (mm) 87 87 49
Code Description Specification Operating Voltage 24V dc 220A 6mA 0.5 mm to 2.5 mm MRIAD Loop connected remote indicator

Quiescent Current Alarm Current Cable Size Environmental


W

Operating Temperature Humidity (Non Condensing) Physical Construction Colour Lens Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +55C 0 to 95% RH

ABS White Red 87mm x 87mm x 49mm 0.28kg IP30

Menvier intelligent addressable fire systems

Standard Connection
MRIAD
screen connected using suitable terminal in backbox

Installation
1. Mounting plate fixes to single gang back box or can be direct fixed to wall or ceiling. 2. Cable entry is normally from rear but breakouts are provided in side of base plate 3. Cables connect to terminals on PCB within base plate. 4. Front cover is pushed onto base plate and locks in place.

System Functionality
1. MRIAD is addressable and is programmed to activate when selected detectors are triggered. 2. LED cancels when detector is reset. 3. Low current consumption.

- + - +
LOOP IN
Compatible Menvier Intelligent Addressable Control Panel

OUT

IN

Terminal block unplugs for ease of connection

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

LOOP OUT

Product Codes
Code MRIAD Description Intelligent addressable loop connected remote indicator

74

Intelligent Addressable Product Range

Reflective Beam Detectors MAB50R and MAB100R

optional mounting bracket with cable clamp facilities

MAB50R and MAB100R reflective beam detectors

Overview
The Menvier loop powered reflective beam detectors are specifically designed to function with the latest intelligent addressable Menvier control panels. combined transmitter and receiver for ease of installation Two versions are available, the MAB50R with a range of up to 50 metres, and the MAB100R with a range of 50 - 100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard loop wiring so no additional interconnection required.

Features
Quick and simple to install IP40 protection Simple loop connection No power supply required

Benefits
Saves time and installation costs Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance, especially in warehouses with racking

75

Intelligent Addressable Reflective Beam Detectors - MAB50R and MAB100R

Dimensions
H (mm) W (mm) D (mm) 210 130 120
H D

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current Alarm Current Alignment Current 18V dc to 30V dc <5mA (no LEDs illuminated) <9mA <18mA 10 seconds (approx) 5 to 50 metres 18V dc to 30V dc <5mA (no LEDs illuminated) <9mA <18mA 10 seconds (approx) 50 to 100 metres MAB50R Reflective beam detector EN54 Pt 12 & 17 2002 MAB100R Reflective beam detector EN54 Pt 12 & 17 2002

Power up Time Operating Range Tolerance to Beam Misalignment at 35% Fire Alarm Thresholds Optical Wavelength Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

Detector 0.8, Prism 5.0 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 880nm

Detector 0.8, Prism 5.0 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 880nm

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

PC/ABS White 210mm 130mm x 120mm 0.8kg IP40

PC/ABS White 210mm 130mm x 120mm 0.8kg IP40

Menvier intelligent addressable fire systems

Menvier intelligent addressable fire systems

Standard Connection
MAB50R / MAB100R
to beam detector socket

Installation
1. Must be fixed to solid structure. 2. Recommended mounting height is 0.3 to 0.6 metres below the ceiling. 3. Cables can be terminated into separate termination box (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately. 4. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector. 5. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation.

System Functionality
1. Beam detectors have 3 modes Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly. Alignment mode Enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator. Normal running mode

+ - + LOOP IN
Compatible Menvier Intelligent Addressable Control Panel

OUT

IN

screen connected using suitable terminal in backbox

LOOP OUT

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

User Interface
1. Beam detectors status LEDs Red LED constantly illuminated indicates fire condition Flashing amber LED indicates fault condition

Product Codes
Code MAB50R MAB100R MRBFP Description Intelligent addressable reflective beam detector 50m range Intelligent addressable reflective beam detector 100m range Mounting bracket

76

Intelligent Addressable Product Range

Callpoints MBG813 and MBG817

MBG817 weatherproof callpoint

MBG813 callpoint

Overview
This attractively designed simple to install range of callpoints have been specifically developed to be compatible with Menvier intelligent addressable fire systems. There are two versions of callpoint in this range. The MBG813 which can be either surface or flush mounted and the MBG817 weatherproof version. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications.

Features
Fast fit clip on front cover High visibility status LED Standard and weatherproof versions available Wide range of available accessories Heavy duty terminals

MBGHCC protective hinged cover

Benefits
Quick and simple to install Fast fit clip on front cover Single tool for test and access

MBGBEZ recessing bezel

77

Intelligent Addressable Callpoints - MBG813 and MBG817

Dimensions
W

Technical Specification
Code Description Standards Specification Operating Voltage 17V dc to 32V dc < 250A 17V dc to 32V dc < 250A MBG813 Surface / flush mounting callpoint EN54 Pt11 MBG817 Weatherproof callpoint EN54 Pt11

Quiescent Current Environmental Operating Temperature Humidity (Non Condensing)

-10C to +55C 0 to 93% RH

-10C to +55C 0 to 93% RH

Physical Construction PC/ABS Red 87mm x 87mm x 57mm (36mm flush) 0.2kg IP42 PC/ABS Red 87mm x 87mm x 59mm 0.2kg IP65

Description H (mm) Flush mounted 87 Surface mounted 87 Weatherproof 87

W (mm) 87 87 87

D (mm) 36 57 59

Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

Menvier intelligent addressable fire systems

Menvier intelligent addressable fire systems

Standard Connection
MBG813 / MBG817
Screen Screen OUT

Installation
1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate loop in and loop out terminals are provided for all connections including screen continuity on intelligent addressable callpoints. 7. Surface/flush callpoints are IP42, weatherproof is IP65.

Accessories
Semi recess bezel Spacer plates Hinged clear cover Resettable plastic element Replacement test key Replacement glass elements Earth continuity links

- + E - +
LOOP OUT

Compatible Menvier Intelligent Addressable Control Panel

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

LOOP IN

IN

User Interface
1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element.

Product Codes
Code MBG813 MBG817 MBGHCC MBGSP MBGBEZ MBGREKIT MBG118 MBG119 MFBGKEY3 Description Intelligent addressable surface/flush callpoint Intelligent addressable weatherproof callpoint Protective hinged cover Spacer plates (pack of 10) Recessing bezels (pack of 10) Resettable element kit (pack of 10) Spare break glasses (pack of 5) Earth continuity links (pack of 5) Callpoint keys (pack of 10)

78

Intelligent Addressable Product Range

Wall Sounders MAS850LPS and MAS850LPSWP

MAS850LPSWP weatherproof wall sounder

MAS850LPS internal wall sounder

Overview
The Menvier intelligent addressable wall sounder has been developed specifically to operate with Menvier intelligent addressable control panels. The high efficiency design of these wall sounders offer excellent sound output levels despite the low current consumption. MAS850LPS The Menvier MAS850LPS is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. MAS850LPSWP The Menvier MAS850LPSWP is IP66 rated so suitable for external and wash down areas, it is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation.

Features
MAS850LPS Loop powered High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel Simple clip fixing assembly MAS850LPSWP Weatherproof version (IP66) Loop powered High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel Simple clip fixing assembly

internal base

Benefits
Low current consumption First fix back box Built in short circuit isolators

weatherproof base

79

Intelligent Addressable Wall Sounders - MAS850LPS and MAS850LPSWP

Dimensions
D

Technical Specification
Code
w

MAS850LPS Internal wall sounder EN54 Pt3

MAS850LPSWP Weatherproof wall sounder EN54 Pt3

Description
D

Standards Specification

Operating Voltage
H

17V dc to 32V dc < 320A Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz

17V dc to 32V dc < 320A Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Low volume : 87dB at <2mA Medium volume : 93dB at <3mA High volume: 100dB @ <6mA

Standby Current Tones (set by panel)

Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap

Internal wall sounder Description Internal Weatherproof H (mm) 105 108

Weatherproof wall sounder W (mm) 105 108 D (mm) 95 103

Sound Output @ +/-3dB (set by panel)

Low volume : 87dB at <2mA Medium volume : 93dB at <3mA High volume: 100dB @ <6mA

Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems PC/ABS Red 105mm x 105mm x 95mm 0.25kg IP42 Rear/side PC/ABS Red 108mm x 108mm x 103mm 0.57kg IP66 Rear/side -10C to +55C 0 to 95% RH -10C to +55C 0 to 95% RH

Standard Connection
MAS850LPS / MAS850LPSWP
Screen Screen OUT

Installation
MAS850LPS 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then clipped into position on mounting base, body locks into position when pressed home. MAS850LPSWP 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then fastened onto base, using 4 allen head screws (supplied).

System Functionality
MAS850LPS / MAS850LPSWP 1. Volume is set by fire control panel, no need to access sounder to alter setting. 2. Tone is set by fire control panel, no need to access sounder to alter setting.

E LOOP IN
Compatible Menvier Intelligent Addressable Control Panel

- + E - +
LOOP OUT

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

IN

Product Codes
Code MAS850LPS MAS850LPSWP Description Intelligent addressable internal wall sounder Intelligent addressable weatherproof wall sounder

80

Intelligent Addressable Product Range

Wall Sounder Beacons MASB860 and MASB860WP

MASB860WP weatherproof wall sounder beacon

MASB860 internal wall sounder beacon

Overview
The Menvier intelligent addressable wall sounder beacon has been developed specifically to operate with the latest generation of Menvier intelligent addressable control panels. The high efficiency design offers excellent sound output levels despite the low current consumption. Whilst also includes a high powered LED beacon to provide both audible and visual alarm signals. internal base MASB860 The Menvier MASB860 is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. MASB860WP The Menvier MASB860WP is IP66 rated so suitable for external and wash down areas, it designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation.

Features
MASB860 Loop powered Combined sounder beacon High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel MASB860WP Weatherproof version (IP66) Loop powered Combined sounder beacon High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel

Benefits
Low current High efficency audio / visual unit suitable for DDA compliance

weatherproof base

81

Intelligent Addressable Wall Sounder Beacons - MASB860 and MASB860WP

Dimensions

Technical Specification
Code Description Standards Specification Operating Voltage Standby Current Tones (set by panel) 17V dc to 32V dc < 320A Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap 17V dc to 32V dc < 320A Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Low volume: 92dB at <6.5mA Medium volume: 97dB at <7.5mA High volume: 100dB @ <8.5mA 1Hz MASB860 Internal wall sounder beacon EN54 Pt3 MASB860WP Weatherproof wall sounder beacon EN54 Pt3

Internal wall sounder beacon Description Internal Weatherproof H (mm) 105 108

Weatherproof wall sounder beacon W (mm) 105 108 D (mm) 95 103

Sound Output @ +/-3dB (set by panel)

Low volume: 92dB at <6.5mA Medium volume: 97dB at <7.5mA High volume: 100dB @ <8.5mA

Flash Energy Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Lens Colour Dimensions (H x W x D) Weight Ingress Protection Cable Entry Cable Size / Type Compatibility Suitable for use with

1Hz

-10C to +55C 0 to 95% RH

-10C to +55C 0 to 95% RH

PC/ABS Red Red 105mm x 105mm x 95mm 0.21kg IP42 Rear/side 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC

PC/ABS Red Red 108mm x 108mm x 103mm 0.32kg IP66 Rear/side 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC

Menvier intelligent addressable fire systems

Menvier intelligent addressable fire systems

Standard Connection
MASB860 / MASB860WP
Screen Screen OUT

Installation
MASB860 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main. sounder body. 5. Main body is then clipped into position on mounting base, body locks into position when pressed home. MASB860WP 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then fastened onto base, using 4 allen head screws (supplied).

System Functionality
MASB860 / MASB860WP 1. Volume is set by fire control panel, no need to access sounder to alter setting. 2. Tone is set by fire control panel, no need to access sounder to alter setting.

E LOOP IN
Compatible Menvier Intelligent Addressable Control Panel

- + E - +
LOOP OUT

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

IN

Product Codes
Code MASB860 MASB860WP Description Intelligent addressable internal wall sounder beacon Intelligent addressable weatherproof wall sounder beacon

82

Intelligent Addressable Product Range

Loop Connected LED Beacon MAB870

MAB870 loop connected LED beacon

Overview
The Menvier intelligent addressable loop connected LED beacon is available to complement audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. The Menvier MAB870 is designed for both wall and ceiling mounting, has a built in short circuit isolator and is soft addressed for ease of installation.

Features
High efficiency design LED technology Low profile design

Benefits
Low current High efficency LED / visual unit suitable for DDA compliance

83

Intelligent Addressable Loop Connected LED Beacon - MAB870

Dimensions
Dia (mm) 95
D

Technical Specification
Code MAB870 Loop connected LED beacon

D (mm) 53

Description Specification Operating Voltage Standby Current Alarm Current Flash Frequency Environmental

17V dc to 32V dc < 250A < 4.1mA 1/2Hz

Dia

Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (Dia x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +55C 0 to 95% RH

PC/ABS Red 95mm x 53mm 0.15kg IP54

Menvier intelligent addressable fire systems

Standard Connection
MAB870
Screen Screen OUT

Installation
1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cable entry is from the rear. 4. Connections are to connector block on beacon body. 5. Beacon body is pressed into first fix base then twisted to lock into position.

System Functionality
1. Utilises multiple LED's combined with careful optical design to provide high intensity flash with low current consumption. 2. Low profile design for discreet installation.

E LOOP IN
Compatible Menvier Intelligent Addressable Control Panel

- + E - +
LOOP OUT

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop.

IN

Product Codes
Code MAB870 Description Intelligent addressable loop connected LED beacon

84

Intelligent Addressable Product Range

4 Way Sounder Controller Unit MPU424

MPU424 4 way sounder controller unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MPU424 4 way sounder controller unit is a loop connected interface, which provides the facility to power and control 4 independent conventional sounder circuits. This greatly simplifies installation in applications where specialist sounders or beacons are required by avoiding the need to connect them directly to the intelligent addressable control panel. The unit only uses a single address yet each circuit can be independently controlled according to the required cause and effect programming.

Features
Quick and simple to install Avoids the need to wire conventional sounders back to the main panel 4 separate sounder circuits (0.4A) All outputs are independently programmable Battery backup via integral battery Built in short circuit isolator Built in power supply

Benefits
Plug and play, no hard addressing required Increased system integrity No external short circuit isolator required Beacon and strobe can be wired direct to the interface thereby saving time and cabling Reduce cost of installation

85

Intelligent Addressable 4 Way Sounder Controller Unit - MPU424

Dimensions
D

Technical Specification
H (mm) W (mm) D (mm) 300 300 74
Code Description Standards Specification Operating Voltage 24V dc 250A 230V ac 0.4A 2 x 12 V, 4Ah, SLA 24 hours + 30 minutes ringing 0.4A (max) 1.6A (max) 30V dc 1A (resistive), 0.5 A (inductive) (max) MPU424 4 channel sounder controller unit EN54 Pt4 & Pt17 2005

Quiescent Current Mains Supply Voltage Mains Current Consumption Battery Standby Period Sounder Circuit Output

Sounder Load Fire Relay Switching Voltage Switching Current Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +45C 0 to 95% RH

ABS/steel 300mm x 300mm x 74mm 5.4kg IP30

Menvier intelligent addressable fire systems

Installation
1. The sounder controller interface requires a local unswitched 230V supply and incorporates a back up battery to maintain functionality under mains failure conditions. 2. Cable entry can be top or rear. 3. Top entry is via 20mm conduit entries (pre-fitted with blanking plugs for unused entries). 4. Rear entry via substantial cable slot in metal back plate 5. Top cover secured with tamper resistant screws

Standard Connections
6K8 6K8 6K8 6K8 intelligent addressable loop

230V ac mains

FIRE RELAY
N/O C N/C

OUT

IN

+
+

BATT
-

back up battery

NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be tted, even if input is not used. 3. Sounder circuits are monitored for wiring open and short circuit. 4. Output re relay is a set of changeover volt free-contacts and is not monitored. 5. This unit should only be nally connected to the 230V ac mains supply and battery, during system commissioning.

Product Codes
Code MPU424 Description 4 way sounder controller unit

86

Intelligent Addressable Product Range

Zone Monitor Unit MIU871

MIU871 zone monitor unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIU871 zone monitor unit connects zones of suitable conventional detectors.

Features
Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Only takes a single address Input monitored for open, short circuits and ground trouble Built in short circuit isolator

Benefits
Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required

87

Intelligent Addressable Zone Monitor Unit - MIU871

Dimensions
H (mm) W (mm) D (mm) 88 147 60
W

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current Alarm Current 18V dc to 30 V dc 2.8mA 8mA 3.4mA 20 detectors per zone (max) Unlimited MIU871 Zone monitor unit EN54 Pt17 & Pt18 2005

H D

Current with 20 Detectors Detector Load Callpoint Load Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +60C 0 to 95% RH

PC/ABS 88mm x 147mm x 60mm 0.23kg IP40

Menvier intelligent addressable fire systems

Installation
1. Zone monitor unit is fixed to a deep double gang back box (supplied). 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom, side or rear. 4. Can be surface or semi recessed mounted.

Standard Connections
EOLM-1 6K

- OUT + - IN +
intelligent addressable loop

- OUT+ - IN +

IN

OUT LOOP

CALLPOINT ZONE

DETECTOR ZONE

Callpoints can be connected with detectors on detector zone if preferred NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be tted, even if input is not used. 3. Maximum spur length - see BS5839 Pt:1 2002 for zone coverage. 4. There is no maximum number of conventional callpoints allowed per zone output. 5. Unit can only be used with its respective Cooper re systems and compatible sensor and base.

Note:

The MIU871 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Product Codes
Code MIU871 Description Zone monitor unit

88

Intelligent Addressable Product Range

Shop Monitor Unit MSU840

MSU840 shop monitor unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MSU840 shop monitor unit is designed to enable small units with conventional fire detection to be fully integrated with a main intelligent addressable fire system. It is ideal for applications such as connecting individual shop units into a main shopping centre system. An external power supply is required to drive the 2 conventional sounder circuits. This power supply must be regulated for fire and current limited.

Features
Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Provides 2 conventional sounder circuits Only takes a single address Includes output changeover relay Inputs monitored for open, short circuits and ground trouble

Benefits
Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required Reduced installation cost by using the 2 sounder circuits

89

Intelligent Addressable Shop Monitor Unit - MSU840

Dimensions
H (mm) W (mm) D (mm) 88 147 60
W

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current Quiescent Load Current 15V dc to 30V dc 3.4mA (max) 2.8mA (max) 8mA (max) MSU840 Shop monitor unit EN54 Pt17 & Pt18

H D

Alarm Current Zone Circuits Number Input Circuits Zone Circuit 1 Zone Circuit 2 Number of Callpoints Callpoint Resistance Zone Circuit 1 EOL Zone Circuit 2 EOL Number of Detectors Short Circuit Fault Threshold Open Circuit Fault Threshold Sounder Circuits Number of Sounder Circuits Load per Output Sounder Circuit 1 and 2 EOL Relay Fire Relay Single Pole C/O Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

2 Callpoints only Detectors and Callpoints Unlimited 470 to 680 6K8 Active EOL 20 (max) 150 N/A active EOL

2 300mA (max) 12K

1A - 30V dc

-10C to +60C 0 to 95% RH

PC/ABS 88mm x 147mm x 60mm 1kg IP40

Menvier intelligent addressable fire systems

Standard Connections
EOLM-1

24V dc output power supply unit 12K 12K


FAULT CONTACT N/O 24V O/P

6K8
- Out + - In +

intelligent addressable loop

12K
- Out + - In +

N/O C N/C + +
1

OUT LOOP

IN

CALLPOINT DETECTOR ZONE ZONE

+
2

SOUNDER FIRE RELAY

24V EXTERNAL EXTERNAL PSU PSU MONITOR INPUT

callpoints can be connected with detectors on detector zone if preferred

Note:

The MSU840 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Product Codes
Code MSU840 Description Shop monitor unit

90

Intelligent Addressable Product Range

Spur Isolator Unit MSI850

MSI850 spur isolator unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MSI850 spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop, the device is designed to simplify installation of remote parts of buildings or for simple system extensions.

Features
Quick and simple to install Allows a spur of intelligent addressable devices to be fed from the main loop Integral short circuit isolators for the loop and the spur Automatically controls addressing sequence Built in short circuit isolator

Benefits
Plug and play no hard addressing required Easy to expand a system using existing wiring Reduced installation cost No external short circuit isolator required

91

Intelligent Addressable Spur Isolator Unit - MSI850

Dimensions
H (mm) W (mm) D (mm) 88 147 60
W

Technical Specification
Code Description Standards Specification Quiescent Current Environmental Operating Temperature -10C to +60C 0 to 95% RH 170A MSI850 Spur isolator unit EN54 Pt17 2005

H D

Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

PC/ABS 88mm x 147mm x 60mm 0.23kg IP40

Menvier intelligent addressable fire systems

Installation
1. Please refer to current edition of BS5839-1 for details of the maximum allowable area to be covered by a single zone. 2. Spur isolator unit is fixed to a deep double gang back box (supplied). 3. All connections are via heavy duty terminals. 4. Cable entry can be top, bottom, side or rear. 5. Can be surface or semi recessed mounted.

Standard Connections

E OUT +
intelligent addressable loop

E IN + SPUR + m

no end of line resistor required

NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. For maximum spur length/load see BS5839 Pt1:2002. 3. Unit can only be used with its respective Cooper re systems and compatible sensor and base.

Product Codes
Code MSI850 Description Spur isolator unit

92

Intelligent Addressable Product Range

3 Channel I/O Unit MIO324

MIO324 3 channel I/O unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIO324 3 channel I/O unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits.

Features
Quick and simple to install Soft addressed 3 separate inputs and 3 separate outputs Inputs monitored for open and short circuits Integral short circuit isolator

Benefits
Plug and play no hard addressing required Built in short circuit isolator no additional hardware required Unit takes 3 inputs, 3 outputs - only 1 address required to monitor and control saving on equipment and installation

93

Intelligent Addressable 3 Channel I/O Unit - MIO324 and MIO324T

Dimensions
H (mm) W (mm) D (mm) 88 147 60
W

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current Maximum Switching Voltage 18V dc to 30V dc 310A 50V ac or 30V dc 1A at 30V resistive, 0.5A inductive MIO324 3 channel I/O unit EN54 Pt17 & Pt18 2005

H D

Output Relay Contact Rating Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +60C 0 to 95% RH

PC/ABS 88mm x 147mm x 60mm 0.23kg IP40

Menvier intelligent addressable fire systems

Installation
1. 3 Channel input output unit is fixed to a deep double gang back box (supplied). 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom, side or rear. 4. Can be surface or semi recessed mounted. 5. Relay contacts are rated at 24V dc 1A.

Standard Connections
5K6
5K6

5K6

22K intelligent addressable loop

22K

22K

N/O C N/C

OUTPUTS N/O C N/C N/O C N/C

IN LOOP

OUT

INPUTS

NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be tted, even if input is not used. 3. Input circuit is monitored for wiring open and short circuit. 4. Output relay is a set of changeover volt free-contacts and is not monitored.

Product Codes
Code MIO324 MIO324S MIO324T Description 3 channel I/O unit 3 channel I/O unit, resets on silence 3 channel I/O unit, contains 3 separate addresses

94

Intelligent Addressable Product Range

230V ac Relay Unit MIO1240

MIO1240 relay unit

Overview
An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIO1240 230V ac relay unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches.

Features
Quick and simple to install Soft addressed Only takes a single address Integral short circuit isolator

Benefits
Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required

95

Intelligent Addressable - 230V ac Relay Unit - MIO1240

Dimensions
D

Technical Specification
H (mm) W (mm) D (mm) 129 180 60
Code Description Standards Specification Operating Voltage 18V dc to 30V dc 310A 250V ac or 30V dc 8A MIO1240 230V ac relay unit EN54 Pt17 & Pt18 2005

Quiescent Current Maximum Switching Voltage Maximum Switching Current Environmental

Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +60C 0 to 95% RH

PC/ABS 129mm x 180mm x 60mm 0.6kg IP65

Menvier intelligent addressable fire systems

Installation
1. Mains rated input relay is designed for surface fixing. 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom or side. 4. Output relay contacts are rated at 230V ac.

Standard Connections

5K6

intelligent addressable loop

22K

volt-free output 230V rated

N/C N/O

IN

OUT

SPUR INPUT

NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be tted, even if input is not used. 3. Input circuit is monitored for wiring open and short circuit. 4. Output relay is a set of changeover volt free-contacts and is not monitored.

Product Codes
Code MIO1240 Description 230V ac relay unit

96

Intelligent Addressable Product Range

Micro Zone Monitor Unit MIU872

MIU872 micro zone monitor unit

Overview
An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIU872 is a single zone input, soft addressed, micro interface, incorporating integral short circuit isolators. It is fully compatible with the current range of Menvier intelligent addressable fire detection panels. It is suitable for interfacing a zone of up to 20 conventional Menvier detectors onto a Menvier intelligent addressable control panel. It will operate with any Menvier conventional detector in configuration with a schottky diode type base.

Features
Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Only takes a single address Input monitored for open and short ground trouble Active end of line monitoring Built in short circuit isolator

Benefits
Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required

97

Intelligent Addressable Micro Zone Monitor Unit - MIU872

Dimensions
H (mm) W (mm) D (mm) 65 35 18.5
D

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current 18V dc to 30V dc 2.6mA (nom) MIU872 Micro zone monitor unit EN54 Pt17 & Pt18

Load With 20 Detectors, and Unlimited Callpoints Alarm Load With 20 Detectors, and Unlimited Callpoints 8.0mA (nom) 3.2mA (nom)

Mounting Details

Detector Zone Detectors per Zone End of Line Monitor Fire Input Trigger Resistance Short Circuit Fault Threshold Resistance 100 (max) 20 (max) Active end of line unit - EOLM-1 680 (nom)

22mm

Open Circuit Fault Threshold Resistance Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) PC/ABS 65mm x 35mm x 18.5mm 0.28kg IP40 -10C to +60C 0 to 95% RH 39K (min)

37.5mm

Weight Ingress Protection Compatibility Suitable for use with

Menvier intelligent addressable fire systems

Installation
1. Suitable for use with any Menvier conventional detector. 2. Connections suitable for single strand fireproof cable up. to 2.5mm2. 3. Loop and output cable screen must be connected to interface earth terminals. Note: No addressing of the interface is required (see control panel operation for details)

Standard Connections
EOLM-1
IN+ INEARTH

LOOP IN

maximum 20 Cooper conventional detectors

INPUT

LOOP OUT

Note:

The MIU872 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base)

Product Codes
Code MIU872 Description Micro zone monitor unit

98

Intelligent Addressable Product Range

Micro Single Channel Output Units MCOM

MCOM-R micro single channel output unit

MCOM micro single channel output unit

Overview
An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Menvier intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Optional Variants The MCOM-R gives a 5 second pulse on reset. The MCOM-S is identified by the panel as a sounder. Dose not reset on silence, resets on reset only.

Features
Quick and simple to install Compact size Soft Addressed Integral short circuit isolator

Benefits
Plug and play no hard addressing required No external short circuit isolator required

MCOM-S
MCOM-S micro single channel output unit

99

Intelligent Addressable Micro Single Channel Output Units

Dimensions
H (mm) W (mm) D (mm) 65 35 18.5
D

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current 18V dc to 30V dc 310A MCOM Micro single channel output unit EN54 Pt17 & Pt18

Output Relay Switching Voltage Contact Rating Switching Power 24V dc to 30V dc 1A 30 Watts

Mounting Details

Environmental Operating temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) PC/ABS 65mm x 35mm x 18.5mm 0.078kg IP40 -10C to +60C 0 to 95% RH

22mm

Weight Ingress protection Compatibility Suitable for use with

Menvier intelligent addressable fire systems

Installation
37.5mm

1. Suitable for switching 24V dc control circuits (fire door retainers etc). 2. Connections suitable for single strand fireproof cable up to 2.5mm2. 3. Loop and output cable screen must be connected to interface earth terminals. 4. The relay output is a set of change over, non-latching, volt free contacts which are non monitored. Note: No addressing of the interface is required (see control panel operation for details)

Standard Connections
N/O N/C C OUTPUT

LOOP IN

LOOP OUT

Product Codes
Code MCOM MCOM-S MCOM-R Description Micro single channel output unit (recognised as output unit) Micro single channel output unit (recognised as sounder) Micro single channel output unit (5 second reset pulse)

100

Intelligent Addressable Product Range

Micro Single Channel Input Units MCIM

MCIM-NF micro single channel output unit

MCIM micro single channel output unit

Overview
An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MCIM is a single input, soft addressed micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. MCIM-C micro single channel output unit The MCIM is fully compatible with the current range of Menvier intelligent addressable fire control panels. It is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches, auxiliary panel fire/fault signals as well as non fire input signals such as flow valve open contacts, generator start up, fire door closed etc. Optional Variants The MCIM-NF is designed for non-fire applications. The MCIM-C is identified by the panel as a callpoint.

Features
Quick and simple to install Compact size Soft Addressed Integral short circuit isolator

Benefits
Plug and play no hard addressing required No external short circuit isolator required

101

Intelligent Addressable Micro Single Channel Input Units

Dimensions
H (mm) W (mm) D (mm) 65 35 18.5
D

Technical Specification
Code Description Standards Specification Operating Voltage Quiescent Current 18V dc to 30V dc 310A MCIM Micro single channel input unit EN54 Pt17 & Pt18

Inputs Trigger Resistance End of Line Resistor Short Circuit Fault 5K6 22K

Mounting Details

Threshold Resistance Open Circuit Fault Threshold Resistance Environmental Operating temperature Humidity (non condensing)

1K

33K

-10C to +60C 0 to 95% RH

22mm

Physical Construction Dimensions (H x W x D) Weight Ingress protection Compatibility Suitable for use with Menvier intelligent addressable fire systems PC/ABS 65mm x 35mm x 18.5mm 0.078kg IP40

37.5mm

Installation
1. Inputs monitored for open and short circuit fault conditions. 2. Suitable for monitoring normally open volt free contacts (flow switches etc). 3. Connections suitable for single strand fireproof cable up to 2.5mm2. 5. Loop and output cable screen must be connected to interface earth terminals 6. The end of line monitoring resistor, must always be fitted at the end of the input wiring, if the input is unused the end of line resistor must be fitted at the interface input terminals. Note: No addressing of the interface is required (see control panel operation for details)

Standard Connections
5K6
IN+

22K

INEARTH INPUT

LOOP IN

LOOP OUT

Product Codes
Code MCIM MCIM-C MCIM-NF Description Micro single channel input unit (recognised as input unit) Micro single channel input unit (recognised as callpoint) Micro single channel input unit (non fire input)

102

Ancillaries and Test Equipment

Heavy Duty Relay Unit MAR724

MAR724 heavy duty relay

Overview
The Menvier heavy duty relay unit is designed for interfacing heavy loads such as door release units or plant shut down equipment with fire alarm systems. It is simple to fix and install and the neat unobtrusive design makes it suitable for use in a wide range of areas. The heavy duty relay is powered by 24V dc external supply and is provided with 2 separate sets of changeover contacts. The front mounted status LED illuminates when relay is energised.

Features
Simple to install Visible status indication LED Double pole change over contacts

Benefits
Low current consumption 230V ac rated contacts Will switch up to 10A (resistive)

103

Heavy Duty Relay Unit - MAR724

Dimensions
H (mm) W (mm) D (mm) 89 150 58
W

Technical Specification
Code Description Specification Coil Rating Contact Rating Contacts Environmental 24V dc 10mA 10A at 240V ac or 30V dc 2 x sets of changeover contacts MAR724 Heavy duty relay unit

H D

Operating Temperature Humidity (Non Condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with

-10C to +55C 0 to 95% RH

PC/ABS 89mm x 150mm x 58mm 0.24Kg IP30

Menvier fire systems

Standard Connection
MAR724
RELAY 1 RELAY 2

Installation
1. Heavy duty relay unit fixes to a standard deep double gang back box (supplied). 2. Cable entry is via back box, cables are terminated into heavy duty terminals on relay PCB.

Interface Options
NC C NO NC C NO
Compatible Menvier Control Panel

1. Relay is powered by an external 24V dc supply.

24V dc OUTPUT

WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system.

Product Codes
Code MAR724 Description Heavy duty relay unit

104

Ancillaries and Test Equipment

Power Supply Unit FX1A

FX1A power supply unit

Overview
The FX1A is a 24V dc battery backed power supply unit complete with back up batteries. The output is continuous and transition from mains to battery is without break in the output. It is monitored and has local fault indication as well as volt free contacts for remote fault signalling, making it ideal as a general purpose power supply for fire alarm applications.

Features
Compact enclosure Integral battery Fault indicator Remote fault contact

Benefits
Simple to use Secure steel enclosure Built in battery back up

105

Power Supply - FX1A

Dimensions
D W

Technical Specification
H (mm) W (mm) D (mm) 230 323 77
Code Description Standards Specification Maximum Continuous Load 0.8A 1.0A 2 x 12V 2.1 Ah 3A at 24V dc Mains input, charger output, system output 27.5V dc 20.4 - 24V dc dependant on battery status FXA1 Power supply unit EN54 Pt4

Maximum Intermittent Load Standby Batteries Fault Relay Contact Rating Fuse Protection Output Voltage (mains healthy) Output Voltage (mains failed) Physical Construction Dimensions (H x W x D) Ingress Protection Compatibility Suitable for use with

Mild steel 230mm x 323mm x 77mm IP30

Menvier fire systems

Installation
1. Enclosure is designed for wall mounting. 2. 2 x 20mm knockouts are provided for cable entry at the top of the enclosure. 3. A fused terminal block is provided for mains supply connection. 4. Output is protected by internal 1.5A fuse.

System Functionality
1. FX1A power supply provides a maximum output of 1A. 2. Output is used to supply any connected load and also to recharge the integral batteries. 3. To enable batteries to be charged correctly maximum continuous external load should not exceed 0.8A. 4. LED indicators are provided to signify: Mains healthy System fault Output supply fault Charger output fault 5. Mains healthy and system fault LED's are visible without removing front cover.

Product Codes
Code FX1A FASP0429 Description 24V dc power supply unit, with battery backup 24V dc power supply unit, no battery backup

106

Ancillaries and Test Equipment

Loop Tester Kit LP800KIT

LP800KIT loop tester kit in box

LP800KIT loop tester

Overview
The LP800 loop tester is a hardware / software combination that can be used to test, commission and fault find a loop of up to 200 Menvier intelligent addressable devices (sensors, sounders, ancillary devices) without having to connect the loop to the Menvier intelligent addressable fire panel. The loop tester is connected between the loop and PC. It allows the engineer to quickly identify and locate any loop device that is operating outside its operating conditions by varying the alarm threshold of any loop device (alarm, prealarm and fault). The loop tester hardware requires a free serial port on the PC, either internal or via a USB extension, a mains power supply and a direct connection to the device loop.

Features
Pre-addressing: Identifies all Menvier field devices and determines their address and device type Analogue Values: Constantly displays in real time the analogue value of all Menvier loop devices in order to determine their status Test LED: This command operates the LED of any inputs (detector/call points) as well as controls the outputs of sounders and output modules Device Settings: Analogue values of all devices can be interpreted according to ranges which can be set and altered by the user (OK, prealarm, fire) Event Log: A history of events can be stored from the date the application was started Soft addressing: Automatically assigns a new, and potentially different, address to every device found on the loop

LP800KIT loop tester kit box

Product Codes
Code LP800KIT Description Programmer

107

Ancillaries and Test Equipment

Addressable Device Programmer CF800PROG

CF800PROG programmer, back

CF800PROG addressable device programmer

Overview
The CF800PROG programmer is a versatile tool to aid the installation, commissioning, maintenance and servicing of current addressable devices and fire alarm systems. This unit is light, robust and easy to operate using a user friendly menu structure on 2 x 40 character LCD display. It is powered from a single PP3 size, heavy duty battery or an external supply. The programmer has a built in addressable base as well as two external terminals for use with all other current addressable ancillary devices.

Features
Reads addresses Writes addresses Reads analogue values Tests devices Deletes addresses Programmes the 3 heat settings

Product Codes
Code CF800PROG Description Addressable device programmer

108

Notes

109

Notes

110

Global Presence
Cooper Industries is a diversified global manufacturer of world-class electrical products, components and tools, with 2009 revenues of $4.5 billion. The Company has seven operating divisions with manufacturing facilities in 23 countries, and employs more than 25,000 people throughout the world. With its broad range of products and global brands including; Bussmann electrical and electronic fuses; Crouse-Hinds and CEAG explosion-proof electrical equipment; Halo, Metalux, Menvier and Crompton mains and emergency luminaires; Kyle and McGrawEdison power systems products; Menvier and JSB fire systems, Cooper is uniquely positioned for several long-term growth trends, including the current global infrastructure developments, improvements to enhance the reliability and productivity of the electric grid, the increased demand for energy-efficient products and the need for improved electrical safety.

Cooper Industries Environmental Policy


On May 1, 1990, Cooper Industries issued a formal policy to affirm its commitment to the environment. The principles of this policy, reinforce standards of operation already in place and remind employees throughout the world that environmental considerations have the highest priority at Cooper.

The Carbon Trust Standard


In 2010 the UK facilities of Cooper Industries have been awarded the Carbon Trust Standard after taking action on climate change by measuring, managing and reducing its carbon emissions by 17%. The Carbon Trust Standard recognises organisations for real carbon reduction. Based on a rigorous, independent assessment, it certifies that organisations have measured, managed and reduced their carbon emissions across their own operations, and are committed to reducing them year on year.

Principles
To observe all environmental laws and regulations To respond effectively to environmental concerns involving Cooper facilities and products To minimize and, wherever possible, to eliminate the generation of all wastes To conduct operations in a manner that demonstrates respect for the environment To cooperate with federal, state and local governments in developing scientifically based environmental standards To encourage the development of environmentally sound procedures and to conduct business with the best-available technology To maintain environmental monitoring programs that ensure compliance with governmental requirements and these principles To provide training programs that emphasize the individual's responsibility for sound environmental decisions In line with this global policy Cooper Lighting and Safety Ltd has an Environmental Management Policy which satisfies the requirements of BS EN 14001:2004

Cooper Safety Fire Systems Cooper Lighting and Safety Ltd Wheatley Hall Road Doncaster South Yorkshire DN2 4NB United Kingdom www.cooperfire.com

Sales T: +44 (0)1302 303 999 F: +44 (0)1302 303 333 E: sales@cooperfire.com Technical and Quotations T: +44 (0)1302 303 350 F: +44 (0)1302 303 332 E: techsupport@cooperfire.com

Service T: +44 (0)1302 303 352 F: +44 (0)1302 303 332 E: service@cooperfire.com Export T: +44 (0)1302 303 344 F: +44 (0)1302 303 345 E: export@cooperfire.com

Conditions of sale All goods supplied are subject to the companys general conditions of sale which are available on request. Trade Descriptions All descriptions represent only particulars of the goods to which they apply and do not form part of any contract. The company reserves the right to change specification without prior notification or public announcement. 2011 Cooper Lighting and Safety All rights reserved. Publication reference: CFS0018_UK_R1

The trade names and brand names contained herein are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries.

Cooper Industries plc 600 Travis, Suite 5600 Houston, TX 77002 - 1001 T: 713 - 209 - 8400 www.cooperindustries.com

You might also like