QUOTATION To, Principal, Head of the EEE Department, College of Engineering, Andhra Pradesh. Dear Sir , We thank you very much for your enquiry and are pleased to quote as below for M.Tech Power System Lab: All our Products are manufactured to the standards of ISO. Sl. 01 Product Description. Determination of Regulation and Efficiency of Short, Medium and Long Transmission lines. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. To Determine Efficiency and Regulation of 3 phase Transmission model h . 3ph Variable Voltage, Inductors, Capacitors, Wattmeter, Analog Meters MCB for Switching on with fuses and BTI 30 terminals. Fault analysis(LL,LG,LLL) of Trans lines. IDMT Characteristics of Over Current Relay. Non Directional Over Current relay. (IDMT) Time Totalizer, Variable voltage, Variable load and Analog Meters. MCB for Switching on with fuses and BTI-30 terminals. Study of Buccholz Relay. Buccholz Relay, Time Totalizer, Variable voltage, Variable load and Analog Meters. MCB for Switching on with fuses and BTI 30 terminals with compressor. Determination of A,B,C,D parameters of short, medium and long lines. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. To determine ABCD constants :Open circuit and short ckt tests can be conducted in this panel. PF Meter, Wattmeters, and Analog Meters, Variable Supply. MCB for Switching on with fuses and BTI 30 terminals. Differential Protection of Transformer. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. 1 Ph Transformer, Auto Transformer, Analog Meters. MCB for Switching on with fuses and BTI 30 terminals. 1 Over current Relay. Testing of Static differential Relay. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Differential relay consists of operating coil and restraining coil. 3 ph Transformer, Auto transformer, Rheostat, Bridge rectifier, Analog Meters and Terminals. The differential relay is adjustable ,. Sequence Impedance of 3 phase Alternator. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Without Alternator. To determine the Positive, Negative and Zero Sequence impedances or sequence impedances of the given three phase alternator. Analog Meters, Wattmeter Portable, Auto Transformer 3 phase, and necessary Accessories. 5 Hp DC Shunt Motor Coupled to Alternator. Make : Elmo. Determination of Positive, Negative and zero sequence reactance of 3 ph Transformers using sequence current excitation fault calculation. Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. 3 phase Star / Delta Transformer Shell type. 400 / 230 Vac. 1KVA. Variable voltage, and Analog Meters. MCB for Switching on with fuses and BTI 30 terminals. Characteristics of Static Relay UV/OV : Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Relay used is an electronic microcontroller based single phase voltage relay. It is suitable for under / over voltage protection schemes in LV, MV, HV Power Distribution systems. Microprocessor based Relay, Auto Transformer, Timer , Analog Meters and Terminals reqd. Static Excitation of Synchronous Generator : Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Ammeter, Voltmeter, Rheostat, Wattmeter . 5 Hp DC Compound Motor Coupled to Alternator. Make : Elmo. Determinaton of Die electric strength of oils : Price. 1,20,000-00

DEVI ELECTRONICS

Our Ref : DE/001/Dt. 26-01-2013.

02 02b. 03

59,000-00 90,000-00 98,000-00

04

99,000-00

05.

1,95,000-00

06

65,000-00

07

79,000-00 98,000-00

08

59,000-00

09

49,000-00 79,000-00 39,000-00

10

Study of Meggar : Hand wound type. 7,500-00 Parallel Operation of Alternators : Consists of a Panel Closed type with front Hylam sheet. 59,000-00 Panel size 2ft ht x 4 ft wd x 200mm depth. Ammeter, Voltmeter, Rheostat, Wattmeter . 5 Hp DC Compound Motor Coupled to Alternator. 2nos 1,58,000-00 12 Measurement of Capacitance of 3 Core Cables : (Bridge type) 25,000-00 13 Fault Location of Underground Cables : ( Bridge type ) 29,000-00 14 Simulation of string of Insulators for determination of voltage distribution and string efficiency: 19,000-00 Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm . 15 Fault analysis of 3 phase Alternator, (LG, LL, LLG, LLLG faults) Consists of a Panel Closed 43,000-00 type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With All required meters (analog type), voltmeter, ammeter, wattmeter, 1ph variac, mcb, fuses and terminals. 5 Hp DC Shunt Motor Coupled to Alternator Make : Elmo. 79,000-00 16 Determination of sequence Impedances of a Cylindrical Rotor 59,000-00 Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm dpth. Analog Meters, Wattmeter , Auto Transformer 3 phase and terminals etc., 5 Hp DC Shunt Motor Coupled to Alternator (Cylindrical Rotor type) Make : Elmo. 93,000-00 17 Characteristics of Static Negative Sequence Relay. 89,000-00 Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Relay used is an electronic microcontroller based single phase voltage relay. It Microprocessor based Relay, Auto Transformer, Timer , Analog Meters and Terminals reqd. 18 DC Rectifier: DC Rectifier unit fitted with Ammeter and Voltmeter and fuse protection for 1,57,500-00 over load. (DC Power Source to run the DC Motors) (Industrial Grade.) Continuous Rating. Input : 3 Phase 415 Volts AC +/- 10% 50 HZ Output : 220 Volts +/- 2VDC Capacity : 100 AMPS. Make : Devi Electronics Size : 700x1500x600mm 19 Rheostat, 300 ohms, 1.7 amps. 3,500-00 20 Tacho Meter Hand held Contact type , Systems. 2,500-00 21 Determination of Earth resistance under various conditions with accessories. 19,000-00 Earth tester kit, Electrodes, Hammer and connecting wires. 22 Milli Volt Drop Test ( Calibration of Tong Tester). 39,000-00 23 Speed control of Induction motor (3phase) with variable frequency inverter . 99,000-00 V/F control inverter drive , 5 Hp Induction Motor and tachometer (Digital). 24 Four Quadrant Operation of separately excited DC motor using Chopper. 79,000-00 25 Characteristics of Reverse Power Relay. 89,000-00 Consists of a Panel Closed type with front Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. Relay used is an electronic microcontroller based single phase reverse Power relay. Microprocessor based Relay, Auto Transformer, Timer , Analog Meters and Terminals reqd 13 Determination of Xd and Xq on an Alternator. Consists of a Panel Closed type with front 56,000-00 Hylam sheet. Panel size 2ft ht x 4 ft wd x 200mm depth. With All required meters (analog type), voltmeter, ammeter, wattmeter, 1ph variac, mcb, fuses and terminals. 5 Hp DC Shunt Motor Coupled to Alternator Make : Elmo. 79,000-00 Discount : 12.5% on all the above kits. All the above kits are manufactured by us except Motors and oil testing kit. 11 Terms and Conditions : Sales Tax : VAT/CST @ 14.5% Extra. TIN NO :- 28780284346 Delivery Period : 4 to 8 Weeks. Payment Terms : 100% Payment along with Purchase order. Warranty : 1 year. Delivery to the destination will be at your cost. Looking forward to receive your valuable purchase order, Thanking you. For Devi Electronics S.V.Raman. Ph : 09440884985. For any other Requirements Please mail to : svramanhyd@yahoo.com; svramanhyd@gmail.com; Please SMS Your E Mail Id to 09440884985 for Product literatures. For Automation of EEE lab Please Call : 09493975815.

Visit www.devielectronics.com for Specifications.