You are on page 1of 40

The Basics of Hazardous Locations & Lighting

Quality Since 1898


MADE IN USA

Kurtzon Lighting Kurtzon Lighting


www.Kurtzon.com

Applications include:
Class 1 Division 2
Hazardous Research Facilities Food Processing (Bakeries) Compressed Gas Storage Water Treatment Facilities Ethanol Refinement Bio Fuel Production Chemical Plants Oil Refineries Fuel Storage Laboratories Breweries Hospitals Forensic School Mining NASA

Class 2 & 3 Division 2 Mining Schools Forensic Hospitals Laboratories Fuel Storage Oil Refineries Grain Elevators Paper Processing Clothing Manufacturing Government Installations Food Processing (Bakeries) Hazardous Research Facilities

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Why specify Kurtzon Products?


Kurtzon Lighting is an industry leader in hazardous location lighting. Kurtzon Lightings Haz Lock (HL) series fixtures can be specified for use in various areas such as: hazardous research facilities, compressed gas storage, water treatment facilities, government Installations, ethanol refinement, bio fuel production, food processing (bakeries). The features of the HL series meets the critical requirements for these areas of lighting. They are National Sanitation Foundation (NSF) labeled & approved, corrosion resistant, non-toxic and non-absorbent. In fact, Kurtzon lighting was the first manufacturer in the industry to have products listed for Hazardous Locations. They are specifically designed without crevices or recesses. All openings are sealed by NSF listed gasket materials to prevent bacterial growth within the fixture. When it comes to lighting areas with specific health, sanitation and environmental requirements, Kurtzons name stands alone.
Other Literature relating to Hazardous Locations from Kurtzon Lighting:
Clean Room Lighting Guide http://www.kurtzon.com/Catalog/pdf/KLBrochure.pdf Food Processing Lighting Guide http://www.kurtzon.com/Catalog/pdf/KurtzonFPBrochure.pdf

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Key Specification Requirements

STANDARDS
Unsurpassed design & fabrication standards result in a sealed product w/ minimal dependence on gasketing Only company that has knockouts that are UL approved & can mainain a hazardous location listing.

NEMA Premium Fluorescent Ballast Standard On Most Products


20 Gauge Cold Roll Steel, Stainless Steel or Aluminum Construcion

Powder Coated Surfaces 1000 HR Salt Spray - 2H Hardness Tig Welding w/ Reinforced Caulk On All Seams / Knockouts 1 piece 90 Beveled Edges Overlapping Door Triple Gasketing 100% Pure Neoprene UL & CUL Listed For Wet Location Class 1 & 2 Groups A,B,C,D,F & G Inset Door Frame - Class 1 .135 lens P12 Virgin Acrylic Locking Lamp Holders IBEW Labeled STI Myers Hub

OPTIONS
All Exposed Room Side Lenses Are Smooth NSF - Klean Lock Seap Pro Listed Gasket IP65 Listed for Wet Locations Class 1 Cleanroom Rating Tamperproof fastners Tempered Glass Lens Emergency Ballast HD85 Hose Down 85 PSI HD1700 Hose Down for 1700 PSI Fusing

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Hazardous Lighting Background


In 1976, our company received notice from Underwriters Laboratories that its submittal for Class 1, Division 2 Hazardous Location lighting in a recessed mounting was approved, thus creating a first for both Kurtzon Lighting and the lighting industry. The type of demanding environment represented by Class I, Division 2 listing placed the company among the leaders in the industry. In 1994, the Haz-Lock line (HL) of fixtures produced by Kurtzon Lighting were being used by NASA and other end-users requiring fixtures for high tech environments. In this complicated world many workers are exposed daily to the danger of fire or explosion. Even ordinary people are regularly exposed to this type of hazard at the gas station, auto dealership or hospital. Protecting these areas from explosion are organizations such as the American Gas Assoc. (AGA), Factory Mutual (FM), Occupational Safety and Health Act (OSHA), Underwriters Laboratories (UL) and above all, the National Fire Protection Association (NFPA). The NFPA publishes the nations most authoritative and comprehensive document on electrical safety, NFPA 70, National Electric Code (commonly called the NEC). The NEC is a part of the wide variety of safety documents the NFPA publishes. The NEC addresses in chapter five the requirements for electrical equipment and wiring used in locations where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dusts or ignitable fibers. Knowing when and what type of a hazardous location exists is the professional engineers job as well as the local authority with jurisdiction. The NEC contains the requirements needed to design the electrical system in a way that reduces the hazard in the location.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Attributes of Some Class 1 Gases / Vapors


Group
A B C D

Gas
Acetylene Hydrogen Hydrazine Propane

Flammable Range or Limits (Percent by Volume)


Low Concentration

Auto Ignition Temp (F)

Density (Air - 1)

2.5 4.0 2.9 2.1

High Concentration

100 75 98 9.5

580 930 100 100

0.9 0.1 1.1 1.6

Defining Locations:
The specific difference between ordinary and hazardous locations is the presence of a combustible atmosphere. The presence of a fuel in an environment where electric service is provided is the essence of any hazardous location. The term presence is important to define. There are many areas where fuel is or could be made available that are not considered hazardous locations. The determining factor is concentration. Most gaseous fuels have a range of concentration that is ignitable. Above or below this range, the atmosphere may not be ignitable. (Keep in mind that we should always treat the high concentration as a hazard since it would be very easy to reduce the concentration into the hazardous conditions.)

Most gases are heavier or lighter than air, so concentrations in a space may vary greatly throughout the room. A heavy vapor like propane will have a higher concentration near the ceiling. The concentration is important to determine the hazard involved. For instance, natural gas has a flammable (explosive) limit of 5% lower and 15% for a higher limit. When concentrations are below 5%, the mixture is too lean to burn and if it is above 15%, it is too rich to burn. Do not use the upper limit for a margin of safety because the mixture will go through the explosive range during an accidental spillage or release.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Dust / Fibers and Flyings


Another type of hazardous location is where combustible dusts are stored or handled. Combustible dusts are heavier than air and easily accumulate on the surfaces of electrical components, which can insulate them and thereby cause them to overheat. Dusts also can easily be temporarily suspended in an ignitable cloud when released or disturbed. Therefore, some hazardous locations are areas where the build up of a combustible dusts or the generation of a dust cloud is possible. Similarly, other hazardous locations are areas where the build up of combustible fibers or flyings is possible. To summarize, the type of combustible atmosphere present in the environment whether gas, dust or fiber is the key element in the classification and definition of the hazardous location.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Ignition
Ignition happens when the fuel, within the explosive range, in the presence of air, is exposed to an ignition source such as sparks, a flame, or to temperatures above its Auto Ignition Temperature (AIT). The AIT is specific to a volatile mix. Assuming a concentration of natural gas in a normal air environment the AIT is 1000 degrees F. (See chart for other gases AIT values). If heated to this temperature it would ignite and burn without the addition of any other energy such as spark or flame. The AIT is important to determine the type of equipment needed, where this kind of fuel is available. Using a margin of safety, authorities determine the required Maximum Operating Temperatures of heat generating devices such as lighting fixtures, motors, etc., with reference to the AIT. Since a hazardous fuel presence is expected the products intended for use in these environments must be assured of not providing the ignition energy. Electrical equipment must be designed to contain all sparks or flames generated during normal or abnormal conditions as well as not to exceed the maximum operating temperature required for this environment. Once a hazardous location is defined and classified, its requirements must be matched to the correct electrical equipment for use in that environment. Only special electrical equipment is allowed into these environments, and a great deal of effort and expense by manufacturers is devoted to offering this equipment. Only certain organizations, such as UL, have developed standards and procedures for designing and testing of this equipment for hazardous locations. This work is keyed to three important concepts: Class, Division and Group.

For more information on this or any other technical lighting topic please contact your local Kurtzon representative or email us at customerservice@kurtzon.com

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Classes
The type of fuel involved determine classes. Class 1 is related to the gases like hydrogen or gasoline, Class 2 is associated with the dusts like coal and grain dusts. Class 3 encompasses fibers or flyings as found in the textile and woodworking industry; though areas of wood dust are a Class II location.

Divisions
Divisions are the second category used to determine the extent of the hazard. Will the site be exposed to the fuel regularly or rarely due to containment or ventilation system failure? The answer to this question determines which division applies to this site.
Division I is the most severe environment. The hazardous

atmosphere is always or is often present or may become present during frequent servicing or repair.

during accidental spillage or the like. These environments are usually storage or handling facilities where the element is kept in sealed containers or closed systems. This division can also be found adjacent to Div I areas where the fuel might occasionally be communicated. Also, Div II environments exist where ignitable concentrations of the fuel are normally prevented by mechanical positive ventilation, which could become hazardous upon failure or abnormal operation of the ventilation systems. Kurtzon offers many lighting products for Division II (Classes I, II & III).

Division II is where the hazardous atmosphere is only available

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Hazardous Locations (NEC & IEC) Standard and Alternate Methods of Classifying Locations
Standard Method (Classified) NEC Article 500-504

Class 1 Gases, Vapors and Liquids Division 1 Regularly Present Division 2 Accidentally Present

Class 2 Dusts

Class 3 Fibers and Flyings Division 1 Regularly Present Division 2 Accidentally Present

Division 1 Regularly Present

Division 2 Accidentally Present

Groups A, B, C & D

Groups E, F & G

Groups F & G only

No Groups for Class III

Alternate Method Classes and Zones NEC Article 505 Requires Supervision of a Registered P.E.
Class 1 Gases, and Dusts Zone 0 Continuosly Present Zone 1 Regularly Present Zone 2 Accidentally present for short periods

Group IIC, IIB & IIA (Approx. Inverse Relationship To Article 500 Groups)

For more information on this or any other technical lighting topic please contact your local Kurtzon representative or email us at customerservice@kurtzon.com

HL-A-1-40

HL-LPB-1-40

HL-C-2-40

HL-D-1-40

HL-F-1-2x4

HL-S-3-2x4

HL-F-2-2x2

HL-S-3-541

10

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Groups
The last major category for specifying a hazardous location are groups. Hazardous materials are separated into groups based on their physical characteristics. Some of these characteristics are explosive energy, particle size and conductivity. The group designation further defines the type of hazard involved and the type of equipment needed to maintain safety. Class I groups are defined as letters A through D. The letter designation refers to the relative pressure generated during an explosion. It does not relate to the AIT, or the flammable range. Class I, Group A gases are capable of generating the highest explosion pressures. Where Group D gases generate the least pressure. Due to the higher explosive energy involved, the equipment destined for group A environments are most difficult to manufacture compared to the group D fixtures. Group designations for Class II areas refer to the type of dust involved. Group E dusts contain combustible metal dusts like coal and some other combustible dusts. Group G dust are the combustible dusts not found in groups E or F.

Protection

There are several ways to provide acceptable protection from electrical equipment in hazardous (classified) locations. Each class may require different methods to arrest the hazard. We provide this section to help you understand the physical differences between the products offered for each class or division.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

11

Explosion Proof
Explosion proof devices for Class I Division I or II. A device, including its enclosure, that is designed to withstand an explosion from within, of a certain gas or vapor. The divide and its enclosure also prevent the ignition of the same surrounding atmosphere by arresting sparks, flame, hot gases or flashes created within the fixture. In addition, the external operating temperature (hottest extended surface) will not ignite the surrounding hazardous gas or vapor. It is expected that an explosion will occur within the enclosure. Protection is only afforded by controlling the energy released from the enclosure. One of the key methods used to control the explosive energy release is usually unexpected. The fixtures are not sealed. The fixtures are purposely designed with special leak paths that allow for the safe exit of the expanding gases from an internal explosion. Concentric rings, special threads and/or machined joints are what leak the exhaust of the explosion. If these leaks were sealed, the fixture might rupture and ignite the surrounding atmosphere. The process of leaking hot gases from the enclosure is important. The escaping gases must be cooled well below the auto ignition temperature of the surrounding atmosphere or the flame could spread. Once cooled by the flame fronts close contact with the metal escape path, the exhaust is no longer a hazard. Explosion proof devices are suitable for both Division I and Division II Class I environments.

12

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Class I Div. II
Protection for Class I Div. II devices are handled differently based on the device. You can use products listed for Class I Division I in these areas. You can also use many of the other methods of protection as found in the NEC. One of the more economical methods is to provide electrical devices that are NRLT listed to meet the specific features described by the NEC for Div. II installations. Fixtures, for instance, must be designed to contain all arcing and sparking. In addition to this, other construction requirements / tests must be done to determine the maximum operating temperature of every surface of the fixture, inside or out. These fixtures are marked with the maximum operating temperature or the Temperature Range Code and the maximum ambient temperature (room temperature). Products listed for this area are also marked with the Class, Division and Group. The NEC still allows Enclosed and Gasketed or what used to be called Vapor tight fixtures for this area but regulatory agencies have all but eliminated this fixtures use in practice.
For more information on this or any other technical lighting topic please contact your local Kurtzon representative or email us at customerservice@kurtzon.com

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

13

Purged and Pressurized


Another protection method is the purged and pressurized (P&P) system. This system is created using purged and pressurized enclosures in conjunction with a protective gas to reduce the classification of internal enclosure spaces to a new Division II space or possibly a non-classified space. The protective gas must be supplied at a suitable pressure and flow to prevent the entrance of the hazardous element (gas, dust or fiber). In addition, protective measures must be taken to provide safeguards against pressure system failure. There are three types of purged and pressurized systems: Type X, reduces the classification within the protected enclosure from Div I to non-classified (ordinary) locations. Type Y, Div I to Div II. and Type Z, Div. II non-classified for more information on P&P see NFPA 49608.

Intrinsically Safe
This is another recognized form of protection for hazardous locations. The protection comes from limiting the energy available to a level incapable of igniting the hazardous atmosphere even when in an overload or abnormal condition. This protection is usually used for control circuits and measurement equipment such as thermocouples, LEDs and pressure sensors. Nonincendive circuits and nonincendive components are permitted where approved for Class I, Div II locations and are similar to the intrinsically safe, in that they will not ignite the atmosphere.

Class II
Dust-ignition proof construction excludes dust from inside the enclosure and when properly installed will not permit arcs or sparks or heat to ignite an exterior accumulation or cloud of a specific dust on or near the enclosure. The exclusion of dust from the inside of the enclosure and the effect of the dust build-up on external temperatures are two of the concerns addressed by Laboratory testing.

14

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Class III
The methods of protection for this category are similar to the ones provided for Class II in that they relate to keeping the fibers out of the device and containing any arcs or sparks and avoiding overheating of the components.

Paint Spray Booths


This space has special requirements regarding lighting fixtures. Surface mounted fixtures installed inside must be rated for Class I or II, Div. I. Where recessed fixtures are in use in ceiling or walls the Division II products may in some conditions be applied if they are additionally listed for paint spray booths. The lens frame must provide for control of an interlock switch wired to disable the application process. This interlock would prevent the generation of vapor if the fixture lens is not sealed. Another method of lighting these areas uses break resistant clear tempered glass panels separating the classified space from fixed mounted Division 2 listed fixtures (as required) installed outside of the booth. Fixture installation must be so that radiant or conductive heat will not create excess heat that may ignite residue or vapor on or near the glass panel. This allows the use of less expensive wiring methods and equipment as well. Consult NFPA Article 516 for specifics regarding this application.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

15

Laboratory Testing
In the United States there are several nationally recognized testing laboratories that test and approve hazardous location products. The products that have approval are published in books or directories. These directories are available to local authorities to verify the suitability of a product for a certain application. One of these books is called the Hazardous Location Equipment Directory published by Underwriters Laboratories Inc. commonly called the UL Red Book.

FOR INFORMATIONAL PURPOSES ONLY None of the forgoing information is to be construed in any way as a replacement for the guidance, advice or approval of a qualified professional engineer. As always, consult your local authority and all relevant standards.
1. The NEC does not classify areas where ammunition, blasting powder or dynamite is used, made or stored. These areas are covered by other regulating authorities who may use classified products as part of their safety precautions, even though the products have not been evaluated for such service 2. Values are referenced to standard temperatures and pressures. The lower limits are lower and the upper limits are higher when the temperature is increased.

Other Literature relating to Hazardous Locations from Kurtzon Lighting:


Clean Room Lighting Guide http://www.kurtzon.com/Catalog/pdf/KLBrochure.pdf Food Processing Lighting Guide http://www.kurtzon.com/Catalog/pdf/KurtzonFPBrochure.pdf

For more information on this or any other technical lighting topic please contact your local Kurtzon representative or email us at customerservice@kurtzon.com

16

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Glossary
Auto Ignition Temperature (AIT) - The temperature where burning may start without presence of a flame, spark or arc. Classes - Shown as I, II or III. Distinctions made between the type of hazard involved regarding the kind of fuel in the environment. Classified - Referring to areas or electric components that are or for hazardous locations. Concentration - Expressed in percentages of the subject fuel such as 25% hydrogen where the balance is in air. Density - Expressed as a factor usually referenced to air or water to help determine whether a fuel will rise or fall. (In this document it is referenced to air which equals 1.0) Divisions - Shown as 1 or 2. Distinctions made between the extent of the hazard involving the likelihood of the exposure to the hazard. Explosion - The spontaneous violent burning of fuel. Flash point - The temperature where a flammable liquid becomes a gas. Flying - Small, light and thin polymeric materials, typically the result of a manufacturing process. Fuel - Chemical or molecular energy stored in many forms, liquid, gas or solid. They usually contain a form of hydrogen or carbon or both. Groups - Shown as letters A through G. Further Distinctions made between the types of fuels and their specific explosive characteristics or particle size. Fuels are grouped together when they pose a similar hazard. Groups A through D are for Class I and include gases, liquids and vapors. Groups E, F & G are dusts for Class II locations. There are no groups for Class III locations. Hermetically Sealed - (As it applies here) A seal that is created by the fusion of glass to metal or metal to metal. Ignition source - The introduction of sufficient energy to cause burning. Listed - Referring to a product that has been tested or otherwise evaluated for safety be a nationally recognized testing laboratory. Nonincendive - Low energy electrical systems or components designed to not ignite an atmosphere. NRTL - Nationally Recognized Testing Laboratory such as Underwriters Laboratories and Canadian Standards Assoc. Temperature Code - An assigned designation referenced to a maximum operating temperature range for a heat generating device such as a motor or lighting fixtures. Zones - A new method of describing locations that are hazardous due to the presence of fuels.

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

17

Haz-Lock Series Air-Flow Vega Luminaires for T-Bar Installation Class I Division 2, Group A, B, C, & D
Project:

HL01

Specifications: Housing: Die-formed 20-gauge CRS or type 304 stainless steel construction. Regressed welded ends secure endcaps or adjacent fixture housing. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125 White/Opal Acrylic Lens See Options for other lens choices. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Two .312 holes for mounting to T-Bar. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.

Fixture Type:

Cross Section 2.12

6.25

Installation Detail (2) .312 Holes

36.0 48.125

Ordering Information: HL Series HL - AFV Installation Type AFV = Surface T-Bar Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal Size Lamps Voltage 120V 277V 347V* UNV* Options H/FF = Hazardous Fuse & Holder 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* TP = Stainless Steel Tamperproof Fasteners WHT= White Finished Stainless Steel LPA= Linear Prismatic Clear Acrylic* UVA= Near clear UVA (<380nm) filter lens UVB= Yellow UVB (<450nm) filter lens

Qty/Type

40 = 4' Housing

1/T8 = F32T8 32W T8 (G13) (T-code T4A)

* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

18

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 1x4 Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings and CRS door frames. Stainless steel doorframes are satin polished unless option WHT is chosen. See SSP option for satin (#4) polished stainless steel housings. Installation: Four .312 holes for surface mounting. Two .875 flattened and silicone sealed knockouts for wiring through cast 1/2 hub. See below for mounting options. Listings: UL and CUL Listed for Wet Location, Hazardous Locations Class I, Div. 2, Groups A, B, C & D. IBEW Union Label. Ordering Information: HL Series HL -S Installation Type S = Surface Material 1 = CRS Hsg. & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = AL Hsg. & SS Door Size Lamps Voltage 120V 277V 347V* UNV* Options
12.0 Cross Section 4.50
Project: Fixture Type:

HL02

Installation Detail

3.5

(4) .312 Holes

12.06

36.0 48.12

Qty/Type

1x4 = 1'x4 Housing

1, 2 or 3/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Steel Door LEX = .125 Prismatic Polycarbonate A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass PMB= Pendant Mount Brackets (not feed) SSP= Satin Polished Stainless Housings
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

19

Haz-Lock Series 1x4 Luminaires for Recessed Flange Installation Class I Division 2, Group A, B, C, & D
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Adjustable toggle arm mounting standard. See Options for yoke mounting system (YOKE). Four .875 flattened and silicone sealed knockouts for wiring through supplied trade size cast hub. Listings: UL and CUL Listed for Wet Location, Hazardous Locations Class I, Div. 2, Groups A, B, C & D. IBEW Union Label. Ordering Information: HL Series HL -F Installation Type F = Flanged Recessed
(for Drywall or Plaster)
12.0 Ceiling Cutout 48.5

HL03

Project: Fixture Type:

Cross Section Toggle Arms


(Standard)

Yoke (Optional) 4.50

13.25 x 50.25

Material

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Steel Door LEX = .125 Prismatic Polycarbonate HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass PF= Plaster frame (For wet plaster ceilings) YOKE= Yoke Mounting System
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

1 = CRS Hsg. & Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & Door 4 = Alum. Hsg. & SS Door

Qty/Type

1x4 = 1'x4 Housing

1, 2 or 3/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

20

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 2x2 and 2x4 Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder 14.0 coat finish standard for all housings and CRS door frames. Stainless steel doorframes are satin polished unless option WHT is chosen. See SSP option for satin (#4) polished stainless steel housings. Installation: Four .312 holes for surface mounting. Two .875 flattened and silicone sealed knockouts for wiring through cast 1/2 hub. See below for mounting options. Listings: UL and CUL Listed for Wet Location, Hazardous Locations Class I, Div. 2, Groups A, B, C & D. IBEW Union Label. Ordering Information: HL Series HL -S Installation Type S = Surface Material 1 = CRS Hsg. & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door Size Lamps Voltage 120V 277V 347V* UNV* Options
Project: Fixture Type:

HL05

Cross Section

4.50 24.1 x 48.12

Installation Detail

(2) .875" KO's Gasketed (4) .312 Holes Access Cover

24.1

36.0 48.12

Qty/Type

2x2 = 2'x2 Housing

2, 3 or 4/T8 = F17T8 17W T8 (G13) (T-Code= T4A) 1 or 2/T8U6 = F32T8/U/6 (6 U-Lamp, G13) 2 or 3/T8U1 = F31T8/U (1.625 U-Lamp, G13) 2 or 3/BX = 40-Watt Biax (2G11) 2, 3 or 4/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

2x4 = 2'x4 Housing

H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Steel Door LEX = .125 Prismatic Polycarbonate A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass SSP= Satin Polished Stainless Housings
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

21

Haz-Lock Series 2x2 and 2x4 Luminaires for Recessed Flange Installation Class I Division 2, Group A, B, C, & D
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Adjustable toggle arm mounting standard. Consult factory for yoke mounting system option (YOKE). Four .875 flattened and silicone sealed knockouts for wiring through supplied trade size cast hub. Listings: UL and CUL Listed for Wet Location, Hazardous Locations Class I, Div. 2, Groups A, B, C & D. IBEW Union Label. Ordering Information: HL Series HL -F Installation Type F = Flanged Recessed
(for Drywall or Plaster) Project: Fixture Type:

HL06

Cross Section Toggle Arms


(Standard)

Yoke (Optional) 4.50 25.25 x 50.25


Ceiling Cutouts

2x2

24.0

25.0

2x4

24.0

49.0

Material

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Steel Door LEX = .125 Prismatic Polycarbonate A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass PF= Plaster frame (For wet plaster ceilings) YOKE= Yoke Mounting System
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

1 = CRS Hsg. & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

2x2 = 2'x2 Housing

2, 3 or 4/T8 = F17T8 17W T8 (G13) (T-Code= T4A) 1 or 2/T8U6 = F32T8/U/6 (6 U-Lamp, G13) 2 or 3/T8U1 = F31T8/U (1.625 U-Lamp, G13) 2 or 3/BX = 40-Watt Biax (2G11) 2, 3 or 4/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

2x4 = 2'x4 Housing

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

22

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 2x2 and 2x4 Luminaires for 1.0 and 1.5 Recessed T-Bar Grid Installation Class I Division 2, Group A, B, C, & D
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Standard luminaires accommodate 1.0 & 1.5 T-Bar Grid. Four .875 flattened and silicone sealed knockouts for wiring through supplied trade size cast hub. Listings: UL and CUL Listed for Wet Location, Hazardous Locations Class I, Div. 2, Groups A, B, C & D. IBEW Union Label. Ordering Information: HL Series HL -G Installation Type G = T-Bar Grid
(1 & 1.5 T-bar ceilings) Project: Fixture Type:

HL07

Cross Section 5.0 24.0 x 48.0

Housing Detail

21.0 (4) .875 KO's

23.75

42.0 48.0

Material

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Steel Door LEX = .125 Prismatic Polycarbonate A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass EQ= Earthquake Clips for seismic support
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

1 = CRS Hsg. & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

2x2 = 2'x2 Housing

2, 3 or 4/T8 = F17T8 17W T8 (G13) (T-Code= T4A) 1 or 2/T8U6 = F32T8/U/6 (6 U-Lamp, G13) 2 or 3/T8U1 = F31T8/U (1.625 U-Lamp, G13) 2 or 3/BX = 40-Watt Biax (2G11)

2x4 = 2'x4 Housing

2, 3 or 4/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

23

Haz-Lock Series 4 Luminaires for Corner Mount Installation Class I Division 2, Group A, B, C, & D
Project:

HL08

Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Door Frame: 20-gauge CRS or type 304 stainless steel channel door frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85). Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for CRS housings and Door frames. Stainless steel housings and door frames are satin polished unless option WHT is chosen. Installation: Four .312 holes for surface mounting. Meyers Hub (ST-1) provided for field drilling or installation in one of six locations. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label. Ordering Information: HL Series HL - COR Installation Type Material Size Lamps

Fixture Type:

Cross Section 7.50

7.50 8.12

Installation Detail Top and Rear 36.0

7.50

48.12

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown GG = NSF listed SealPro Gasket WHT= White Finished Stainless Hsg. & Door LEX = .125 Prismatic Polycarbonate PA= Prismatic P12 Pattern Clear Acrylic* A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass
* * Standard ballasts are are compatible with every Note: Not all options electronic for T-8 lamps. option. Ex: EBPRS isT-12Compatibleand high Standard ballasts for not rapid start with EBL. Consult factory for multiple options marked "*". output are magnetic type.

COR = Surface Corner 1 = CRS Hsg. & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = AL Hsg. & SS Door

Qty/Type

40 = 4 Housing

1, 2 or 3/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

24

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series Vega A - 2 , 4 and 8 Acrylic Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125" White/Opal high impact blend virgin acrylic. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Project: Fixture Type:

HL09

Cross Section
3.7"

4.50"

Ordering Information: HL Series HL -A Installation Type A = Vega Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal Size Lamps Voltage 120V 277V 347V* UNV* Options H/FF = Hazardous Fuse & Holder H/FD = Double Hazardous Fuse & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

1/T8 = F17T8 17W T8 (G13) T-code T4A 1/T8 = F32T8 32W T8 (G13) T-code T4A 2/T8 = F32T8 32W T8 (G13) T-code T4A

* Note: Not all options are compatible with every fixture. Ex: 2/EB is not compatible with 20 model. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

25

Haz-Lock Series Vega B - 2' , 4' and 8' Acrylic Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125" White/Opal high impact blend virgin acrylic. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Project: Fixture Type:

HL10

Cross Section 5.5"

6"

Ordering Information: HL Series HL -B Installation Type B = Vega Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
1 or 2/T8 = F17T8 17W T8 (G13) 1 or 2/T8 = F32T8 32W T8 (G13) 2 or 4/T8 = F32T8 32W T8 (G13) (Tandem)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

26

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series Vega C - 2' and 4' Acrylic Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125" White/Opal high impact blend virgin acrylic. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Cross Section 8" 2.625" Project: Fixture Type:

HL11

Ordering Information: HL Series HL -C Installation Type C = Vega Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
2/T8 = F17T8 17W T8 (G13) 2/T8 = F32T8 32W T8 (G13)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

27

Haz-Lock Series Vega D - 2' , 4' and 8' Acrylic Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reector: High reectance white powder coat nished (min. reectivity 88%). Lens: Smooth surface .125" White/Opal high impact blend virgin acrylic. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat nish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel nish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Cross Section 9.00"
Project: Fixture Type:

HL12

4.00"

Ordering Information: HL Series HL -D Installation Type D = Vega Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
2, 3 or 4/T8 = F17T8 17W T8 (G13) 2, 3 or 4/T8 = F32T8 32W T8 (G13) 4, 6, or 8/T8 = F32T8 32W T8 (G13) (Tandem)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

28

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series Linear Prismatic A - 2' , 4' and 8' Polycarbonate Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125 clear linear prismatic polycarbonate. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
4.50"

HL13

Project: Fixture Type:

Cross Section
3.7"

Ordering Information: HL Series HL - LPA Installation Type LPA = Linear Poly Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
1/T8 = F17T8 17W T8 (G13) 1/T8 = F32T8 32W T8 (G13) 2/T8 = F32T8 32W T8 (G13) (Tandem)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

29

Haz-Lock Series Linear Prismatic B - 2' , 4' and 8' Polycarbonate Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125 clear linear prismatic polycarbonate. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Project: Fixture Type:

HL14

Cross Section 5.5"

6"

Ordering Information: HL Series HL - LPB Installation Type LPB = Linear Poly Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
1 or 2/T8 = F17T8 17W T8 (G13) 1 or 2/T8 = F32T8 32W T8 (G13) 2 or 4/T8 = F32T8 32W T8 (G13) (Tandem)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

30

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series Linear Prismatic C - 2' and 4' Polycarbonate Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125 clear linear prismatic polycarbonate. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Cross Section 8" 2.625" Project: Fixture Type:

HL15

Ordering Information: HL Series HL - LPC Installation Type Material Size Lamps Voltage 120V 277V 347V* UNV* Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

LPC = Linear Prismatic 1 = CRS External & Internal Surface 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
2/T8 = F17T8 17W T8 (G13) 2/T8 = F32T8 32W T8 (G13)

Qty/Type

20 = 2' Housing 40 = 4' Housing

* Note: Not all options are compatible with every option. Ex: CRM is not Compatible with HD85. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

31

Haz-Lock Series Linear Prismatic D - 2' , 4' and 8' Polycarbonate Wrap Luminaires for Surface Installation Class I Division 2, Group A, B, C, & D
Specifications:
Housing: Double channel housing of 20-gauge CRS, stainless steel or aluminum construction. End Caps: Precision stamped 20-gauge stainless steel end caps secured to housing hub assembly at each end with a threaded knurled ring. Gasket: Closed cell 100% pure neoprene gasketing. See Option GG for SealPro NSF Listed closed cell gasketing. Reflector: High reflectance white powder coat finished (min. reflectivity 88%). Lens: Smooth surface .125 clear linear prismatic polycarbonate. Lamps: Select lamps listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start (0F) universal voltage (120-277 volt). See options for other choices. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. See Options for white powder coated stainless. Installation: Four .312 debossed holes for surface mounting. Stainless steel Hub/Ring/Plug assembly provided for wiring through end caps. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.
Cross Section 9.00"
Project: Fixture Type:

HL16

4.00"

Ordering Information: HL Series HL - LPD Installation Type LPD = Linear Poly Surface Material 1 = CRS External & Internal 2 = SS Ext. & CRS Internal 3 = SS External & Internal 4 = AL Ext. & CRS Internal
2, 3 or 4/T8 = F17T8 17W T8 (G13) 2, 3 or 4/T8 = F32T8 32W T8 (G13) 2, 4, or 8/T8 = F32T8 32W T8 (G13) (Tandem)

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* GG = N.S.F. Listed Gasketing TP = Stainless Steel Tamperproof Fasteners HD85 = 85 P.S.I. Hosedown WHT= White Finished Stainless Steel PMB= Pendant Mount Bracket PA= Linear Prismatic Clear Acrylic*

Qty/Type

20 = 2' Housing 40 = 4' Housing 80 = 8' Housing

* Note: Not all options are compatible with every option. Ex: 2/EB is not compatible with H/EM. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

32

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 2 x 2 H.I.D. Luminaires for Surface Installation (400-Watt Max) Class I Division 2, Group A, B, C, & D
Project:

HL17

Specifications: Housing: Lapped and spot welded 20-gauge CRS or stainless steel construction. Door Frame: One-piece type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Door frame gasketed to housing and secured with 12 captive flush mounted stainless steel fasteners. See Options for 1700 PSI rating (HD-1700). Reflector: Die-formed semi-specular aluminum reflector. Vertical lamp, Type V distribution. Lens: Inverted .156 C73 tempered glass lens silicone sealed in door frame and secured with continuous stainless steel lens retention system. Lamps: See lamp options listed below. Lamps supplied by others. Mogul base sockets standard. See Options for medium base sockets (MBS). Electrical: CWA high power factor, open core and coil ballast standard. See Options for encapsulated ballast. Finish: White powder coat finish (1,000 hour salt spray test) or 4-B (satin polish) stainless steel finish. Stainless steel housings and doorframes are satin polished unless option WHT is chosen. Installation: Four .312 holes for surface mounting. Meyers Hub (ST-1) provided for field drilling. Listings: National Sanitation Foundation (NSF) Listed. UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C, & D). IBEW Label.

Fixture Type:
Cross Section

16.00

23.64

Installation Detail 23.75 14.50

.312" HOLES

14.50 23.75

Ordering Information: HL Series HL - S Installation Type S = Surface Material 1 = CRS Hsg, & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 150PMH = 150-Watt Pulse Metal Halide 175MH = 175-Watt Metal Halide 250PMH = 250-Watt Pulse Metal Halide 250MH = 250-Watt Metal Halide 400PMH = 400-Watt Pulse Metal Halide 400MH = 400-Watt Metal Halide Size Lamps Voltage 120V 277V 347V Options H/FF =KTK Fuse & Holder H/FD = Two KTK Fuses & Holders MBS = Medium Base Socket ENC = Encapsulated Ballast GG = N.S.F Listed Gasketing HD1700 = 1700 P .S.I. Hosedown WHT = White Powder Coated Hsg. & Door TIG = One-piece TIG Welded Housing

541 = 2 x 2 Housing

* Note: Quartz restrike is not available for Hazardous Locations. Consult Factory for other standby or emergency lighting options.

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

33

Haz-Lock Series 2 x 2 H.I.D. Luminaires for Recessed Flange Installation (400-Watt Max) Class I, Division 2, Group A, B, C, D.
Specifications: Housing: Lapped and spot welded 20-gauge CRS or stainless steel construction. National Sanitation Foundation (NSF) Listed gasketing material provided to seal housing flange to ceiling structure. Door Frame: One-piece type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Door frame gasketed to housing and secured with 12 captive flush mounted stainless steel fasteners. See Options for 85 PSI rating (HD-85). Reflector: Die-formed semi-specular aluminum reflector. Vertical lamp, Type V distribution. Lens: Inverted .156 C73 tempered glass lens silicone sealed in door frame and secured with continuous stainless steel lens retention system. Lamps: See lamp options listed below. Lamps supplied by others. Mogul base sockets standard. See Options for medium base sockets (MBS). Electrical: CWA high power factor, open core and coil ballast standard. See Options for encapsulated ballast. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all CRS housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Adjustable toggle arm mounting system is standard. Meyers Hub (ST-1) provided for field drilling. Listings: UL and CUL Listed for Wet Location and Hazardous Locations, Class I, Division 2, Groups A, B, C & D. IBEW Union Label.
C SI ZE
Ceiling Cutout

HL18

Project: Fixture Type:


Cross Section

16.0

Installation Detail

23.0

23.75

Note: This fixture is not for T- Grid installation.

EW

23.0

23.75

Ordering Information: HL Series HL - F Installation Type F = Flange Material 1 = CRS Hsg, & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 150PMH = 150-Watt Pulse Metal Halide 175MH = 175-Watt Metal Halide 250PMH = 250-Watt Pulse Metal Halide 250MH = 250-Watt Metal Halide 400PMH = 400-Watt Pulse Metal Halide 400MH = 400-Watt Metal Halide Size Lamps Voltage 120V 277V 347V Options H/FF =KTK Fuse & Holder H/FD = Two KTK Fuses & Holders MBS = Medium Base Socket ENC = Encapsulated Ballast GG = N.S.F Listed Gasketing HD1700 = 1700 P .S.I. Hosedown PF = Plaster Frame WHT = White Finished Stainless Door

541 = 2 x 2 Housing

* Note: Quartz restrike is not available for Hazardous Locations. Consult Factory for other standby or emergency lighting options.

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

34

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 2 x 2 H.I.D. Luminaires for Recessed T-Bar Grid Installation (400-Watt Max) Class I, Division 2, Group A, B, C, D.
Specifications: Housing: Lapped and spot welded 20-gauge CRS or stainless steel construction. National Sanitation Foundation (NSF) Listed closed cell gasketing provided on housing flange for positive seal to ceiling. Door Frame: One-piece type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Door frame gasketed to housing and secured with 12 captive flush mounted stainless steel fasteners. See Options for 85 PSI rating (HD-85). Reflector: Die-formed semi-specular aluminum reflector. Vertical lamp, Type V distribution. Lens: .156 C73 tempered glass lens silicone sealed in door frame and secured with continuous stainless steel lens retention system. Lamps: See lamp options listed below. Lamps supplied by others. Mogul base sockets standard. See Options for medium base sockets (MBS). Electrical: CWA high power factor, open core and coil ballast standard. See Options for encapsulated ballast. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all CRS housings. Stainless steel door frames are satin polished unless option WHT is chosen. Installation: Standard luminaires accomodate 1.0 & 1.5 T-Bar Grid. See Options for 2.0 T-Bar Grids. Meyers Hub (ST-1) provided for field drilling. Listings: UL and CUL Listed for Wet Location and Hazardous Locations, Class I, Division 2, Groups A, B, C & D. IBEW Union Label.
Project: Fixture Type:

HL19

16"

24.0"x 24.0"

Installation Detail

.875 KO 24

24
Ordering Information: HL Series HL - G Installation Type G = Grid 1.0 & 1.5 T-Bar Material 1 = CRS Hsg, & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 150PMH = 150-Watt Pulse Metal Halide 175MH = 175-Watt Metal Halide 250PMH = 250-Watt Pulse Metal Halide 250MH = 250-Watt Metal Halide 400PMH = 400-Watt Pulse Metal Halide 400MH = 400-Watt Metal Halide Size Lamps Voltage 120V 277V 347V Options H/FF =KTK Fuse & Holder H/FD = Two KTK Fuses & Holders MBS = Medium Base Socket ENC = Encapsulated Ballast GG = N.S.F Listed Gasketing HD1700 = 1700 P .S.I. Hosedown WHT = White Finished Stainless Door

541 = 2 x 2 Housing

* Note: Quartz restrike is not available for Hazardous Locations. Consult Factory for other standby or emergency lighting options.

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

35

Haz-Lock Series 1x4 Luminaires for Recessed Flange Installation Class I, II & III Division 2, Group A, B, C, D, F & G
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: One-piece 18-gauge CRS or 20-gauge type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Secured by 12 captive stainless steel screws. See Options for 1700 PSI rating (HD-1700). Gaskets: NSF Listed closed cell microcellular extruded KleanLock SealPro with vulcanized corners making a one-piece acid, alkali, oil and solvent resistant gasket system. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat fin- 12.0 ish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Adjustable toggle arm mounting standard. See Options for yoke mounting system (YOKE). Four .875 flattened and silicone sealed knockouts for wiring. Listings: UL and CUL Listed for Wet and Hazardous Locations. Class I, II & III Division 2, Groups A, B, C, D, F & G Listing (X12 & X22). Dust and water resistance rated IP-65. IBEW Label. Note: This fixture is not suitable for T-Bar Grid ceiling systems. Ordering Information: HL Series HL - FDF Installation Type Material Size Lamps Voltage 120V 277V 347V* UNV* Options
12.75 x 49.25 Project: Fixture Type:

HL20

Cross Section Toggle Arms


(Standard)

Yoke (Optional) 4.50

Ceiling Cutout 48.5 12.0"

FDF = Flanged Recessed 1 = CRS Hsg, & CRS Door (for Drywall or Plaster) 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

1x4 = 1'x4 Housing

1, 2 or 3/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD1700 = 1700 P.S.I. Hosedown WHT= White Finished Stainless Door LEX = .125 Prismatic Polycarbonate PA= Prismatic P12 Pattern Clear Acrylic* A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass PF= Plaster Frame (For wet plaster ceilings) YOKE= Yoke Mounting System
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

36

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 1x4 Luminaires for 1.0& 1.5 Recessed T-Bar Grid Installation Class I, II & III Division 2, Group A, B, C, D, F & G
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: One-piece 18-gauge CRS or 20-gauge type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Secured by 12 captive stainless steel screws. See Options for 1700 PSI rating (HD-1700). Gaskets: NSF Listed closed cell microcellular extruded KleanLock SealPro with vulcanized corners making a one-piece acid, alkali, oil and solvent resistant gasket system. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Standard luminaires accomodate 1.0 and 1.5 T-Bar Grid. Meyers Hub (ST-1) provided for field drilling or installation in one of four locations. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C & D, Class II Division 2, Groups F & G, and Class III). IBEW Label. Ordering Information: HL Series HL - GDF Installation Type GDF = T-Bar Grid
(1 & 1.5 T-bar ceilings) Installation Detail (4) .875 KO's Project: Fixture Type:

HL21

Cross Section 5.0 12.0 x 48.0

9.0 36.0 48.0

12.0

Material

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD1700 = 1700 P.S.I. Hosedown WHT= White Finished Stainless Door LEX = .125 Prismatic Polycarbonate PA= Prismatic P12 Pattern Clear Acrylic* A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass

1 = CRS Hsg, & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

1x4 = 1'x4 Housing

1, 2 or 3/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

37

Haz-Lock Series 2x2 & 2x4 Luminaires for Recessed Flange Installation Class I, II & III Division 2, Group A, B, C, D, F & G
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated.
Project: Fixture Type: Cross Section Yoke (Optional)

HL22

Door Frame: One-piece 18-gauge CRS or 20-gauge type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 Toggle Arms stainless steel aircraft cables. Secured by 12 captive stainless steel screws. See Op- (Standard) tions for 1700 PSI rating (HD-1700). Gaskets: NSF Listed closed cell microcellular extruded KleanLock SealPro with vulcanized corners making a one-piece acid, alkali, oil and solvent resistant gasket system. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Adjustable toggle arm mounting standard. See Options for yoke mounting system (YOKE). Four .875 flattened and silicone sealed knockouts for wiring. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C & D, Class II Division 2, Groups F & G, and Class III). IBEW Label. Note: This fixture is not suitable for T-Bar Grid ceiling systems. Ordering Information: HL Series HL - FDF Installation Type Material Size Lamps Voltage 120V 277V 347V* UNV* 24.5

4.50 24.75x 49.25 Ceiling Cutouts

2x2

24.0

2x4

24.0

48.5

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD1700 = 1700 P.S.I. Hosedown WHT= White Finished Stainless Door LEX = .125 Prismatic Polycarbonate PA= Prismatic P12 Pattern Clear Acrylic* A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass PF= Plaster frame (For wet plaster ceilings) YOKE= Yoke Mounting System
* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

FDF = Flanged Recessed 1 = CRS Hsg, & CRS Door (for Drywall or Plaster) 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

2x2 = 2'x2 Housing

2, 3 or 4/T8 = F17T8 17W T8 (G13) (T-Code= T4A) 1 or 2/T8U6 = F32T8/U/6 (6 U-Lamp, G13) 2 or 3/T8U1 = F31T8/U (1.625 U-Lamp, G13) 2, 3 or 4/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

2x4 = 2'x4 Housing

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

38

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

Haz-Lock Series 2x2 and 2x4 Luminaires for 1.0& 1.5 Recessed T-Bar Grid Installation Class I, II & III Division 2, Group A, B, C, D, F & G
Specifications: Housing: One piece, seam welded, hole free 20-gauge CRS, stainless steel or aluminum construction. Fully white powder coated. Door Frame: One-piece 18-gauge CRS or 20-gauge type 304 stainless steel door frame with 90 bevelled edges. Door frame suspended from housing by two 8 stainless steel aircraft cables. Secured by 12 captive stainless steel screws. See Options for 1700 PSI rating (HD-1700). Gaskets: NSF Listed closed cell microcellular extruded KleanLock SealPro with vulcanized corners making a one-piece acid, alkali, oil and solvent resistant gasket system. Reflector: Die formed metal with high reflectance white polyester powder coat finish. (minimum reflectivity 88%) Lens: High durability .135 thick virgin acrylic with P12 prismatic pattern. See Options for other choices. Lamps: Select lamp options listed below. Lamps supplied by others. Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for other choices. Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings. Stainless steel doorframes are satin polished unless option WHT is chosen. Installation: Standard luminaires accomodate 1.0 and 1.5 T-Bar Grid. Meyers Hub (ST-1) provided for field drilling or installation in one of four locations. Listings: UL and CUL Listed for Wet Location and Hazardous Locations (Class I, Division 2, Groups A, B, C & D, Class II Division 2, Groups F & G, and Class III). IBEW Label. Ordering Information: HL Series HL - GDF Installation Type GDF = T-Bar Grid
(1 & 1.5 T-bar ceilings) Installation Detail Project: Fixture Type:

HL23

Cross Section

5.0 24.0 x 48.0

21.0 (4) .875 KO's

23.75

36.0 48.0

Material

Size

Lamps

Voltage 120V 277V 347V* UNV*

Options H/FF = Hazardous Fuse & Holder H/FD = Two Hazardous Fuses & Holders 2/EB = Two Ballasts, (Two Circuits)* EBL = -20F Electronic Ballast* EBPRS= Program Rapid Start Ballast* H/EM = 1 Lamp Battery Pack (700L)* H2/EM = 2 Lamp Battery Pack (1300L)* TP = Stainless Steel Tamperproof Fasteners HD1700 = 1700 P.S.I. Hosedown WHT= White Finished Stainless Door LEX = .125 Prismatic Polycarbonate PA= Prismatic P12 Pattern Clear Acrylic* A19= Prismatic P19 Pattern Clear Acrylic HIA= High Impact P12 Pattern Acrylic TG= Prismatic (C73) Tempered Glass

1 = CRS Hsg, & CRS Door 2 = CRS Hsg. & SS Door 3 = SS Hsg. & SS Door 4 = Alum. Hsg. & SS Door

Qty/Type

2x2 = 2'x2 Housing

2, 3 or 4/T8 = F17T8 17W T8 (G13) (T-Code= T4A) 1 or 2/T8U6 = F32T8/U/6 (6 U-Lamp, G13) 2 or 3/T8U1 = F31T8/U (1.625 U-Lamp, G13) 2, 3 or 4/T8 = F32T8 32W T8 (G13) (T-Code= T4A)

2x4 = 2'x4 Housing

* Note: Not all options are compatible with every option. Ex: EBPRS is not Compatible with EBL. Consult factory for multiple options marked "*".

Kurtzon Lighting / Quality Since 1898 Website - www.kurtzon.com

Morris Kurtzon, Incorporated 1420 South Talman Avenue, Chicago, Illinois 60608 773/277-2121 FAX 773/277-9164 2008

Kurtzon Lighting Kurtzon Lighting

www.Kurtzon.com

39

Kurtzon Lighting
Quality Lighting Made in Chicago, IL since 1898 Quality Lighting Made in Chicago, IL since 1898

Hazardous Location Lighting

WWW.KURTZON.COM
800-837-8937 1420 S. Talman Ave Chicago, IL

You might also like