You are on page 1of 73

CommScope Fiber Optic Cable Products

Fiber Optic Cable Products

Fiber Optic Cable Products


> Loose Tube > Central Tube > Fiber Drop > Hybrids > Tight Buffered

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

FIBER OPTIC CABLE PRODUCTS

CommScope Fiber Optic Cable Products


Fiber Optic Cable Products

Fiber Optic Cable

Fiber Optic Cable Overview .................................................................................................... F3 Fiber Optic Catalog Numbering Key ....................................................................................... F7 Cabled Fiber Specifications Singlemode Fiber................................................................................................................. F8 Multimode Fiber Specifications ........................................................................................... F11 Loose Tube Cable Designs Dry Stranded Loose Tube Armored..................................................................................... F13 Dry Stranded Loose Tube All-Dielectric ............................................................................... F14 Dry Double Jacketed/Single Armored Stranded Loose Tube................................................ F15 Arid-Core Stranded Loose Tube Armored ......................................................................... F16 Arid-Core Stranded Loose Tube All-Dielectric .................................................................... F17 Arid-Core Double Jacketed/Single Armored Stranded Loose Tube .................................... F18 Arid-Core Mini Stranded Loose Tube Armored .................................................................. F19 Arid-Core Mini Stranded Loose Tube Non-Armored .......................................................... F20 LSZH Arid-Core Mini Stranded Loose Tube Armored ......................................................... F21 LSZH Arid-Core Mini Stranded Loose Tube Non-Armored ................................................. F22 High Density Stranded Loose Tube .................................................................................... F23 ADSS Short Span Stranded Loose Tube .............................................................................. F24 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.250in) ............................... F25 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.250in) ....................... F26 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Armored (0.250in) .............. F27 Self-Supporting Figure-8 Arid-Core Dry Stranded Loose Tube Non-Armored (0.250in)...... F28 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.188in) ............................... F29 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.188in) ....................... F30 Self-Supporting Figure-8 Dry Stranded Loose Tube Armored (0.109in) ............................... F31 Self-Supporting Figure-8 Dry Stranded Loose Tube Non-Armored (0.109in) ....................... F32 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric................................... F33 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube All-Dielectric .............................. F34 Riser-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor .................. F35 Plenum-Rated, Indoor/Outdoor Dry Stranded Loose Tube with Interlocking Armor .............. F36 Central Tube Cable Designs Central Tube Armored ....................................................................................................... F37 Central Tube All-Dielectric .................................................................................................. F37 Riser-Rated, Indoor/Outdoor Central Tube All-Dielectric ..................................................... F38 Fiber Drop Cable Designs Drop Armored ................................................................................................................... F39 Drop All-Dielectric ............................................................................................................. F40 Messengered Drop (0.109in) ............................................................................................. F41 Messengered Drop (0.083in) ............................................................................................. F42 Figure-8 Mini-Drop (Solid Messenger)................................................................................ F43 Flat Drop ........................................................................................................................... F44 Toneable Flat Drop ............................................................................................................ F45 LSZH, Indoor/Outdoor Central Tube All-Dielectric .............................................................. F46 ConQuest Fiber Optic Products............................................................................................ F47 Hybrid Cable Designs Fiber/Coax Designs ........................................................................................................... F51 Fiber/Twisted Pair Designs .................................................................................................. F53 Fiber/Tone Wire Designs .................................................................................................... F55 Tight Buffered Cable Designs Riser-Rated, Indoor/Outdoor LSZH Distribution .................................................................. F58 Riser-Rated, Indoor/Outdoor LSZH Cordage ...................................................................... F59 Riser-Rated, Indoor Distribution .......................................................................................... F60 Riser-Rated, Indoor Cordage.............................................................................................. F61 Plenum Rated, Indoor Distribution ...................................................................................... F62 Plenum-Rated, Indoor Cordage ......................................................................................... F63 Packaging and Shipping Information..................................................................................... F64

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

33 F2

CommScope Fiber Optic Cable Products


Proven Quality and Performance

Fiber Optic Cable Products

The Cable Industrys Fiber Supplier

TM

Better fiber equals better fiber optic cable. CommScope provides key optical and geometrical features in its standard singlemode fiber for fusion splice compatibility with other fiber manufacturers and legacy fiber. LightScope ZWP singlemode optical fiber cable continues a CommScope tradition of being a leader in manufacturing innovative and performanceenhanced products for the cable industry. LightScope ZWP optical fiber cable makes available 30% more usable transmission spectrum, which can be used for return path, enhanced video services such as video on demand (VOD) or Dedicated Wavelength Services for business or other demanding applications.

Outside Plant Cables for Standard and Rugged Environments


For direct buried, underground conduit and aerial installations, CommScope offers several designs, which include a variety of loose tube cables. Design options include Drop Armored, a smaller, lighter weight Central Tube cable construction; Central Tube, Flat Drop, and Stranded Loose Tube cables. Craft friendly product solutions are a foremost requirement in todays fast paced world. CommScope engineers are committed to offering evolutionary improvements and easy-to-handle constructions in our fiber product offering. For example, our Dry Loose Tube family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications. Any of these cables may be factory-installed in a variety of CommScopes ConQuest premium high density polyethylene conduit including Toneable Conduit a patented location and damage prevention solution.

TM

CommScope has developed key families of fiber optic cables specifically to be used throughout the HFC communication hierarchy as well as an offering of fiber optic components including connectors and other passive devices that are commonly required in broadband infrastructure.

Indoor/Outdoor Cables for Strength and Safety Including Low-Smoke Zero-Halogen (LSZH) Types
CommScopes design for these cables offer construction and jacketing suitable for outside usage yet comply with UL and CSA riser (OFNR) or plenum (OFNP) flame standards. This design allows you to run cable through the building entrance without having to terminate and splice different cables together which results in significant savings in time and labor. Cable types include dielectric central tube designs, dielectric stranded loose tube cables and Triathlon , a specially designed low-smoke/zero halogen distribution and cordage cable construction.

Premise Cables for Safety and Performance


CommScopes premises cables are designed to handle the unique stresses of indoor applications. Design options include riser and plenum-rated distribution and cordage cables.
32 F3

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable Products

Test Reports A Higher Standard for Higher Speeds


Every reel of CommScope fiber optic cable is subjected to stringent testing throughout the entire manufacturing process. Our state-of-the-art process controls and testing systems ensure that every meter of CommScope cable consistently meets or exceeds our high standards. To prove that our fiber optic cables exceed industry standards, we go to the extra step of attaching an individual cable test report to each reel. In addition to the paper copy of the test reports, we also offer WebTrak, a web program that puts cabling factory results on-line for all of our fiber optic cables. It is our understanding that sometimes this critical test information is misplaced or never makes it to the end-user. With WebTrak, it is easy to find that important paperwork; CommScopes web interface puts factory testing reports for individual cables on-line for 24 hour immediate access. The patented and trademarked WebTrak program resides on our commscope.com website for quick access from any computer. For access to the electronic test reports, all the installers need is the 11 digit serial number printed on the cable jacket and a footage or meter marker for reference. Installers can then enter this number on the WebTrak portion of the CommScope website and pull up the cables factory test results from anywhere in the world at any time of the day or night. Provides documentation of CommScope fiber optic cable performance, allowing a convenient way to track a reel of cable and verify performance. Provides an alternative to managing paper reports. With WebTrak, you can get all the information you need on-line. Provides quick verifications to ensure the product meets or exceeds performance requirements, should there be a performance issue in the field. Provides easy 24/7 access via the internet. WebTrak is just one more example of how CommScope listens to our customers and delivers. You get proof-positive that the cable you purchase will perform to the level you require. Remember, a network is only as good as the cable that connects it. Specify the cables that make networks work fiber optic cables from CommScope.

Request a FREE Broadband Applications & Construction Library


CommScopes Broadband Applications & Construction Library includes a 5-piece set of valuable reference manuals plus a DVD containing essential training videos on topics such as connectorization, expansion loop formation and fiber optic splicing. These tools teach you how to protect the integrity of your broadband plant while lowering operating/installation costs. From construction and installation practices, to performance and testing of cable CommScope Construction Manuals are simply a must-have for anyone upgrading or maintaining broadband networks. Download a PDF version at our website: http://www.commscope.com or request a set by phone at 1-800-982-1708.

CommScopes Broadband Resource Center This repository of experience, knowledge, services and tools is provided to CommScope customers to assist installers, technicians, engineers, designers and managers of broadband service providers. Tools in various media and formats include: SpanMaster software for cable sag and tension calculations; center conductor sizing guides; attenuation slide rules; and call center spec assistance and review. Call us at 1-866-333-3BRC (3272) or e-mail brc@commscope.com for answers to product questions or issues related to any CommScope broadband product.
TM

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

33 F4

CommScope Outside Plant Cables


Robust Dielectric and Armored Constructions

Fiber Optic Cable Products

All CommScope Outside Plant (OSP) cables are designed and manufactured to provide outstanding mechanical and optical performance. This cable family includes a loose tube construction to provide multiple levels of protection for the fiber strands. We manufacture all loose tube cables with appropriate Excess Fiber Length (EFL) to ensure, that when properly installed, the fiber strands will remain strain-free, which is essential to good optical performance and longevity. Our heavyduty products are engineered to withstand the rigors of environmental extremes. There are many cable choices when considering applications that require environmental protection and provide for network diversity. CommScope cable surpasses requirements in the aerial, underground and conduit applications. We offer self-support cable for aerial environments and cable-in-conduit or armored cables for extra protection in burial applications. CommScope manufactures cables that are lightweight, flexible and especially suited for aerial cable installations. Our loose tube cables are available in armored and alldielectric versions.

OSP Fiber Optic Cable Design Options Include: Drop - a small, lightweight Central Tube cable designed for use when space is at a minimum; features a robust PBT buffer tube and is available in fiber counts up to 12 Central Tube - armored and dielectric construction for point-to-point installations in counts up to 48 arranged in easy-to-handle color-coded subunits of 12 fiber each Stranded Loose Tube - for direct buried, underground conduit and aerial installations; design variations range from all-dielectric to armored constructions with up to 576 fibers

Dry Loose Tube Craft friendly product solutions are a foremost requirement in todays fast paced world. CommScope engineers are committed to offering evolutionary improvements and easyto-handle constructions in our fiber product offering. The latest example is our new Dry Loose Tube cable design. This family of gel-free stranded loose tube cables uses all-dry water blocking technology and reduced diameter buffer tubes. The design is completely gel-free, yet provides full water blocking protection for outside plant applications and meets all of the requirements for outside plant cable.

Arid-Core Moisture Barrier CommScope defeats moisture with a unique multi-level approach. In addition to tough outer jacketing, we employ Arid-Core, a super-absorbent polymer technology. Arid-Core is applied between the jacket and the buffer tubes in stranded loose tube cables, and coats the central tubes of drop armored and central tube cables. When moisture meets Arid-Core, the polymer swells to prevent moisture migration - it acts as a mechanical block to prevent further water penetration.

CommScope OSP fiber optic cables are designed to meet or exceed the requirements of Telcordia, EIA/TIA, REA/RUS, IEC and RUS industry standards.

Drop Cables CommScopes Drop family of cables offer craft friendly access product solutions for Fiber to the Premise (FTTP) applications designed for use as systems develop commercial services and expand networks to non-traditional customers. The design of drop cables compliments the needs often found for the last mile of your fiber network. Drop cables offer a compact, flexible and cost-efficient configuration that provides low-loss performance when twelve fibers or less are needed. Drop cables are commonly used to branch from the main cable route to outlying distribution points or the premise. All drop cables can be pre-installed in conduit.

32 F5

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

CommScope Cable Constructions


Fiber Optic Cable Products
Stranded Loose Tube Available in All-Dielectric and Armored designs with up to 576 fibers For Direct Buried, Underground Conduit, and Aerial installations Available in ADSS and Figure-8 constructions Hybrid configurations that include coax or copper conductors are available Mini-Diameter Stranded Loose Tube Smaller, lightweight cable design utilizing 2.0mm buffer tubes Available with up to 144 fibers in Armored, AllDielectric and LSZH designs Improved ease of handling and better utilization of duct space Indoor/Outdoor Stranded Loose Tube Riser, Plenum, and Low Smoke Zero Halogen (LSZH) constructions Eliminates the need for a splice point when entering a building Tough enough for the OSP environment and flame rated for indoor use

Hybrid Cables Flexibility and options for future growth in a single cost-effective cable run Easier material management Drop Cost effective, low fiber count cables for outside plant applications Wide variety of flexible, versatile, and craft-friendly products available For Direct Buried, Underground Conduit, and Aerial Drop applications Small, lightweight cable designs developed for ease of installation Capable of voice transmission, cable location, and site powering

Messenger Figure-8 Multiple messenger size options for increased versatility in designs with up to 60 fibers Allows easy, one-step installation resulting in cost savings Armored and Non-Armored versions with .250 messenger available with up to 288 fibers Central Tube Available in All-Dielectric and Armored designs with up to 48 fibers Effective solution for point-to-point installations Robust constructions offer excellent fiber protection Single buffer tube saves time and reduces termination costs

Premise Cables Complete line of Riser and Plenum rated cables for indoor use Engineered to provide excellent mechanical and optical performance FiberGuard Aluminum Interlocking Armor available
33 F6

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Catalog Numbering Key


Fiber Optic Cable Products

Steps to Building the Catalog Number for the Cable You Need!

CommScope Catalog Number Position

10

11

12

CABLE STYLE (Position 1)


D ......Dry O .....Outdoor (Arid Core Standard) S.......Self-Supporting (ADSS) M .....Messenger P.......Plenum R.......Riser Z ......Zero Halogen

CABLE MARKING (Position 9)


F .........Jacket Sequentially Marked in Feet (standard) M........Jacket Sequentially Marked in Meters X .........Custom Print Required

CABLE CONSTRUCTION SPECIFICS (Position 10)


For outdoor and indoor/outdoor loose tube cables, this value indicates the fiber content per subunit: 01-12.......... Fiber Count Per Subunit For indoor distribution cables, this value indicates additional information pertaining to the cable construction: SU ............... Single Unit Construction MU .............. Multi-Unit Construction For cordage cables, this value indicates the outside diameter: 16 ............... 1.6mm Jacket Outer Diameter 25 ............... 2.5mm Jacket Outer Diameter 29 ............... 2.9mm Jacket Outer Diameter

FIBER COUNT* (Positions 2, 3, & 4)


Total Fiber Count (in increments of two)
*Substitute for XXX variable in catalog number.

CONSTRUCTION (Positions 5 & 6)


Loose Tube Cables LA ..........Stranded Loose Tube Armored LN .........Stranded Loose Tube Non-Armored L2 ..........Stranded Loose Tube Double Jacketed, Single Armored LZ ..........Indoor/Outdoor Stranded Loose Tube, Aluminum Interlocking Armor DA .........Drop Armored DN ........Drop Non-Armored DF .........Flat Drop MN........Mini-Drop Non-Armored CA.........Central Tube Armored CN ........Central Tube Non-Armored, All-Dielectric Tight Buffered Cables DS .........Distribution IC .......Interconnect SP ..........Simplex ZC ......Zipcord

COLOR FIELD (Positions 11 & 12)


For outdoor cables, this field designates the tracer/stripe requirements: NS.................No Stripe (Std) WH....................White BL..................Blue YL ......................Yellow OR ................Orange VI.......................Violet GR ................Green For indoor/outdoor cables, this field designates the jacket color: BK .................Black For indoor cables, this field designates jacket color: OR ......... Orange -62.5 m multimode and composite cables YL .......... Yellow - singlemode cables AQ ......... Aqua - 50 m multimode LazrSPEED cables

Note: Non-standard jacket colors are available. (minimum order required) Please contact your Customer Service Representative for additional information.

FIBER TYPE (Positions 7 & 8)


Singlemode 8W .........LightScope ZWP Dispersion-Unshifted, Matched-Clad, Singlemode Fiber 8F...........Bend Insensitive Singlemode Fiber

ZZ variable in catalog number

NOTES
When Positions 7 & 8 are CM (composite cables), positions 14-23 are required. Positions 14 & 15 ............. Singlemode fiber type Positions 16 - 18............. Singlemode fiber count
(aaa variable in the catalog number)

8T...........LightScope NZD Non-Zero DispersionShifted, Singlemode Fiber


TM

Multimode 6F...........62.5m, FDDI Grade, Multimode Fiber 5M .........LazrSPEED 150, 50m, Multimode Fiber CM.........Composite (Singlemode & Multimode)

Positions 19 & 20 ............. Multimode fiber type Positions 21 - 23 .............. Multimode fiber count
(bbb variable in the catalog number) Please note that positions 13 and above are often used to differentiate similar cable constructions. Please see the individual product pages for additional part number details.

Hybrids HY ..........Fiber/Copper
*XY variable in catalog number

F7

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Available in All CommScope Cable Types

Type 8W Singlemode Fiber Specifications


Fiber Optic Cable Products

Zero Water Peak: Dispersion-Unshifted, Matched-Clad Singlemode Fiber


Standards Compliance: ITU-T G.652.D
Physical Characteristics

Cladding Diameter Core/Clad Offset Coating Diameter (uncolored) Coating Diameter (colored) Coating/Cladding Concentricity Error, maximum Clad Non-Circularity
Mechanical Characteristics

125 0.7 m < 0.5 m 245 10 m 254 7 m 12 m < 1%

Proof Test Coating Strip Force Fiber Curl Dynamic Fatigue Parameter Macrobend 100 turns @ 50 mm mandrel 1310/1550 nm Macrobend 100 turns @ 60 mm mandrel 1625nm Macrobend 1 turn @ 32 mm mandrel 1550 nm
Optical Characteristics, Wavelength Specific

100 kpsi (.69 Gpa) 0.3 - 2.0 lbf (1.3 - 8.9 N) >4m > 20 nd 0.05 dB maximum 0.05 dB maximum 0.05 dB maximum

Attenuation, Loose Tube Cable 1310 nm 1385 nm 1550 nm Attenuation, Tight Buffer Cable 1310 nm 1385 nm 1550 nm Mode Field Diameter 1310 nm 1385 nm 1550 nm Group Refractive Index 1310 nm 1385 nm 1550 nm Dispersion 1310 nm 1550 nm
Optical Characteristics, General

0.34 dB/km 0.31 dB/km 0.22 dB/km 0.50 dB/km 0.50 dB/km 0.50 db/km 9.2 + 0.3 m 9.6 + 0.6 m 10.4 + 0.5 m 1.467 1.468 1.468 3.2 ps/(nm-km) from 1285 to 1330 nm 18 ps/(nm-km)

Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value
Environmental Characteristics

0.10 dB < 1260 nm 1302 - 1322 nm 0.090 ps/(km-nm-nm) < 0.06 ps/sqrt(km)

Temperature Dependence -60C to +85C Temperature Humidity Cycling -10C to +85C up to 95% RH Water Immersion, 23 + 2C Heat Aging, 85 + 2C
Specifications are subject to change without notice.

< 0.05 dB < 0.05 dB < 0.05 dB < 0.05 dB


F8

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Bend Insensitive Type 8F Singlemode Fiber Specifications


Available in All CommScope Cable Types

Fiber Optic Cable Products

Dispersion-Unshifted, Matched-Clad Singlemode Fiber


Standards Compliance: ITU-T G.657.A
Physical Characteristics

Cladding Diameter Core/Clad Offset Coating Diameter (uncolored) Coating Diameter (colored) Coating/Cladding Concentricity Error, maximum Clad Non-Circularity
Mechanical Characteristics

125 0.7 m < 0.5 m 245 10 m 254 7 m 12 m < 1% 100 kpsi (.69 Gpa) 0.3 - 2.0 lbf (1.3 - 8.9 N) >4m > 18 nd 0.01 dB 0.05 dB 0.2 dB 0.5 dB 0.02.dB
0.2 dB

Proof Test Coating Strip Force Fiber Curl Dynamic Fatigue Parameter Macrobend 100 turns @ 50 mm diameter (maximum) 1550 nm 1625 nm Macrobend 10 turns @ 30 mm diameter (maximum) 1550 nm 1625 nm Macrobend 1 turn @ 30 mm diameter (maximum) 1550 nm Macrobend 1 turn @ 20 mm diameter (maximum)
1550 nm Optical Characteristics, Wavelength Specific

Attenuation, Loose Tube Cable 1310 nm 1385 1550 nm Attenuation, Tight Buffer Cable 1310 nm 1385 nm 1550 nm Mode Field Diameter 1310 nm 1550 nm Group Refractive Index 1310 nm 1385 nm 1550 nm Dispersion 1310 nm 1550 nm
Optical Characteristics, General

0.36 dB/km 0.33 dB/km 0.25 dB/km 0.50 dB/km 0.50 dB/km 0.50 db/km 8.9 + 0.4 m 10.0 + 0.5 m 1.467 1.467 1.468 3.5 ps/(nm-km) from 1285 to 1330 nm 18 ps/(nm-km)

Point Defects, maximum Cutoff Wavelength Zero Dispersion Wavelength Zero Dispersion Slope Polarization Mode Dispersion Link Design Value
Environmental Characteristics

0.10 dB < 1260 nm 1302 - 1322 nm 0.092 ps/(km-nm-nm) < 0.06 ps/sqrt(km)

Temperature Dependence -60C to +85C Temperature Humidity Cycling -10C to +85C up to 95% RH Water Immersion, 23 + 2C Heat Aging, 85 + 2C
F9
Specifications are subject to change without notice.

< 0.05 dB < 0.05 dB < 0.05 dB < 0.05 dB

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

LightScope NZD Type 8T Singlemode Fiber Specifications


TM

Available in CommScope Outside Plant Cable Types


Non-Zero Dispersion Shifted Singlemode Fiber
Standards Compliance: ITU-T G.655.C, D
Physical Characteristics

Fiber Optic Cable Products

Cladding Diameter Core/Clad Offset Coating Diameter (uncolored) Coating Diameter (colored) Coating/Cladding Concentricity Error, maximum Clad Non-Circularity
Mechanical Characteristics

125 0.7 m < 0.5 m 245 5 m 256 8 m 10 m < 0.7%

Proof Test Coating Strip Force Fiber Curl Dynamic Fatigue Parameter Macrobend 100 turns @ 75mm mandrel 1550 and 1625 nm Macrobend 1 turn @ 32mm mandrel 1550 and 1625nm
Optical Characteristics, Wavelength Specific

100 kpsi (.69 Gpa) 0.3 - 2.0 lbf (1.3 - 8.9 N) >4m > 20 nd 0.05 dB maximum 0.50 dB maximum

Attenuation, Loose Tube Cable 1310 nm 1550 nm 1625 nm Mode Field Diameter 1550 nm 1625 nm Group Refractive Index 1310 nm 1550 nm 1625 nm Dispersion 1310 nm 1550 nm 1625 nm
Optical Characteristics, General

0.45 dB/km 0.25 dB/km 0.34 dB/km 8.4 + 0.6 m 8.9 + 0.6 m 1.471 1.470 1.470 -8 ps/(nm-km) (typical) 2.6 to 6 ps/(nm-km) from 1530 - 1565 nm 4.0 to 8.9 ps/(nm-km) from 1565 - 1625 nm

Maximum Attenuation at 1385 nm Point Defects, maximum Cutoff Wavelength Dispersion Slope Polarization Mode Dispersion Link Design Value
Environmental Characteristics

0.45 dB/km 0.10 dB < 1260 nm < 0.05 ps/(km-nm-nm) at 1550 nm < 0.04 ps/sqrt(km)

Temperature Dependence -60C to +85C Temperature Humidity Cycling -10C to +85C up to 95% RH Water Immersion, 23 + 2C Heat Aging, 85 + 2C
Specifications are subject to change without notice.

< 0.05 dB < 0.05 dB < 0.05 dB < 0.05 dB


F10

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Type 6F Multimode Fiber Specifications


Available in All CommScope Cable Types

Fiber Optic Cable Products

62.5 micron, FDDI Grade Multimode Fiber


Standards Compliance: TIA 492AAAA (OM1)
Physical Characteristics

Core Diameter Cladding Diameter Core/Clad Offset Coating Diameter (uncolored) Coating Diameter (colored) Coating/Cladding Concentricity Error, maximum Clad Non-Circularity

62.5 2.5 m 125 1.0 m < 1.0 m 245 10 m 254 7 m 8 m < 1%

Mechanical Characteristics Proof Test Coating Strip Force Dynamic Fatigue Parameter Macrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm 0.50 dB maximum 100 kpsi (.69 Gpa) 0.3 - 2.0 lbf (1.3 - 8.9 N) > 18 nd

Optical Characteristics, Wavelength Specific Attenuation, Loose Tube Cable 850 nm 1300 nm Attenuation, Tight Buffer Cable 850 nm 1300 nm Bandwidth, OFL (Over-Filled Launch) 850 nm 1300 nm Group Refractive Index 850 nm 1300 nm 1 GB Ethernet Distance 850 nm 1300 nm 300 m 550 m 1.496 1.491 220 MHz - km 500 MHz - km 3.4 dB/km 1.0 db/km 3.0 dB/km 1.0 dB/km

Optical Characteristics, General Numerical Aperature Point Defects, maximum Zero Dispersion Wavelength Zero Dispersion Slope, maximum Environmental Characteristics Temperature Dependence -60C to +85C Temperature Humidity Cycling -10C to +85C up to 95% RH Water Immersion, 23 + 2C Heat Aging, 85 + 2C
Specifications are subject to change without notice.

0.275 0.015 0.15 dB 1320 - 1365 nm 0.097 ps/(km-nm-nm)

< 0.20 dB < 0.20 dB < 0.20 dB < 0.20 dB

F11

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

LazrSPEED 150 Type 5M Multimode Fiber Specifications

Available in All CommScope Cable Types

Fiber Optic Cable Products

LazrSPEED 150, 50 micron Multimode Fiber


Standards Compliance: Exceeds TIA 492AAAB (OM2+)
Physical Characteristics

Core Diameter Cladding Diameter Core/Clad Offset Coating Diameter (uncolored) Coating Diameter (colored) Coating/Cladding Concentricity Error, maximum Clad Non-Circularity
Mechanical Characteristics

50.0 2.5 m 125 1.0 m < 1.5 m 245 10 m 255 7 m 6 m < 1%

Proof Test Coating Strip Force Dynamic Fatigue Parameter Macrobend 100 turns @ 75mm mandrel 850 nm and 1300 nm
Optical Characteristics, Wavelength Specific

100 kpsi (.69 Gpa) 0.3 - 2.0 lbf (1.3 - 8.9 N) > 18 nd 0.50 dB maximum

Attenuation, Loose Tube Cable 850 nm 1300 nm Attenuation, Tight Buffer Cable 850 nm 1300 nm Bandwidth, OFL 850 nm 1300 nm Bandwidth, Laser 850 nm 1300 nm Differential Mode Delay 850 nm 1300 nm Group Refractive Index 850 nm 1300 nm 1 GB Ethernet Distance 850 nm 1300 nm 10 GB Ethernet Distance 850 nm
Optical Characteristics, General

3.0 dB/km 1.0 dB/km 3.0 dB/km 1.0 db/km 700 MHz - km 500 MHz - km 950 MHz - km 500 MHz - km 0.70 ps/m 0.88 ps/m 1.483 1.479 800 m 600 m 150 m

Numerical Aperature Point Defects, maximum Zero Dispersion Wavelength Zero Dispersion Slope

0.200 + 0.015 0.15 dB 1297 - 1316 nm 0.105 ps/(km-nm-nm)

Environmental Characteristics
Temperature Dependence -60C to +85C Temperature Humidity Cycling -10C to 85C up to 95% RH Water Immersion, 23 + 2C Heat Aging, 85 + 2C
Specifications are subject to change without notice.

0.10 dB 0.10 dB 0.20 dB 0.20 dB

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F12

Outside Plant Gel-Free Stranded Loose Tube Cable


Armored

Fiber Optic Cable Products

Jacket/Armor Combinations for Buried/Underground/Aerial Applications


100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight kg/ km

lbs/ kft

Single Jacket/ Single Armor 2 - 60 Fibers 62 - 72 Fibers

D-XXX-LA-XY-F12NS D-XXX-LA-XY-F12NS

5 6

0.45/11.5 0.47/12.0

6.8/17.3 7.1/18.0

4.5/11.5 4.7/12.0

607/2700 607/2700

180/800 180/800

78 82

116 123

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

D-XXX-LA-XY-F12NS D-XXX-LA-XY-F12NS D-XXX-LA-XY-F12NS D-XXX-LA-XY-F12NS D-XXX-LA-XY-F12NS

8 10 12 18 24

0.53/13.6 0.60/15.1 0.68/17.2 0.68/17.2 0.77/19.6

8.0/20.3 8.9/22.7 10.2/25.8 10.2/25.8 11.6/29.4

5.3/13.6 6.0/15.1 6.8/17.2 6.8/17.2 7.7/19.6

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

103 126 158 141 177

154 188 235 209 264

Singlemode/Multimode D-XXX-LA-CM-F12NS/AAaaa/BBbbb Composite (4-288 Fibers) Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

Refer to above specifications.

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Gel-Free Stranded Loose Tube Armored Cable


(72 Fiber Version Shown)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (2)

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.

F13

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Gel-Free Stranded Loose Tube Cable


Non-Armored, All-Dielectric

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ 2 - 60 Fibers 62 - 72 Fibers

D-XXX-LN-XY-F12NS D-XXX-LN-XY-F12NS

5 6

0.40/10.2 0.42/10.5

6.0/15.3 6.3/15.8

4.0/10.2 4.2/10.5

607/2700 607/2700

180/800 180/800

44 48

66 71

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

D-XXX-LN-XY-F12NS D-XXX-LN-XY-F12NS D-XXX-LN-XY-F12NS D-XXX-LN-XY-F12NS D-XXX-LN-XY-F12NS

8 10 12 18 24

0.48/12.1 0.54/13.7 0.62/15.8 0.62/15.8 0.72/18.2

7.2/18.2 8.1/20.6 9.3/23.7 9.3/23.7 10.7/27.3

4.8/12.1 5.4/13.7 6.2/15.8 6.2/15.8 7.2/18.2

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

63 82 119 89 120

94 121 177 132 179

Singlemode/Multimode D-XXX-LN-CM-F12NS/AAaaa/BBbbb Composite (4-288 Fibers) Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

Refer to above specifications.

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Gel-Free Stranded Loose Tube Non-Armored, All-Dielectric Cable


(72 Fiber Version Shown)
PE Outer Jacket Water Swellable Tape 2.5mm Gel-Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F14

Outside Plant Gel-Free Stranded Loose Tube Cable


Double Jacketed, Single Armored

Fiber Optic Cable Products

Double Jacket for Buried/Underground/Aerial Applications


100% dry stranded loose tube cable reduces cable prep time and keeps gel from getting on clothes, workbenches, or splicing equipment Corrugated steel tape is strong yet flexible, providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons lbs/ kft Weight kg/ km

Double Jacket/ Single Armor 2 - 60 Fibers 62 - 72 Fibers

D-XXX-L2-XY-F12NS D-XXX-L2-XY-F12NS

5 6

0.59/15.0 0.61/15.4

8.9/22.5 9.1/23.1

5.9/15.0 6.1/15.4

607/2700 607/2700

180/800 180/800

129 134

192 200

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

D-XXX-L2-XY-F12NS D-XXX-L2-XY-F12NS D-XXX-L2-XY-F12NS D-XXX-L2-XY-F12NS D-XXX-L2-XY-F12NS

8 10 12 18 24

0.67/17.0 0.73/18.5 0.81/20.6 0.81/20.6 0.90/23.0

10.0/25.4 10.9/27.8 12.2/30.9 12.2/30.9 13.6/34.5

6.7/17.0 7.3/18.5 8.1/20.6 8.1/20.6 9.0/23.0

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

160 189 224 207 255

238 281 334 308 380

Singlemode/Multimode D-XXX-L2-CM-F12NS/AAaaa/BBbbb Composite (4-288 Fibers) Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

Refer to above specifications.

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Gel-Free Stranded Loose Tube Armored Cable Double Jacketed, Single Armored
(72 Fiber Version Shown)
PE Outer Jacket Steel Tape Armoring Water Blocking Tape 2.5mm Gel-Free Buffer Tubes PE Inner Jacket Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP 7 CFR 1755.902 RD Telecommunications Program Listed.

F15

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Arid-Core Stranded Loose Tube Cable

Armored

Fiber Optic Cable Products

Jacket/Armor Combinations for Buried/Underground/Aerial Applications


Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ Single Armor 2 - 60 Fibers 62 - 72 Fibers

O-XXX-LA-XY-F12NS/25T O-XXX-LA-XY-F12NS/25T

5 6

0.45/11.5 0.47/11.9

6.8/17.2 7.0/17.9

4.5/11.5 4.7/11.9

607/2700 607/2700

180/800 180/800

81 86

121 128

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

O-XXX-LA-XY-F12NS/25T O-XXX-LA-XY-F12NS/25T O-XXX-LA-XY-F12NS/25T O-XXX-LA-XY-F12NS/25T O-XXX-LA-XY-F12NS/25T

8 10 12 18 24

0.53/13.5 0.59/15.1 0.68/17.2 0.68/17.2 0.77/19.5

8.0/20.2 8.9/22.6 10.1/25.7 10.1/25.7 11.5/29.3

5.3/13.5 5.9/15.1 6.8/17.2 6.8/17.2 7.7/19.5

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

108 161 133 197 165 246 153 228 194 288

Singlemode/Multimode O-XXX-LA-CM-F12NS/25T/AAaaa/BBbbb Composite (4-288 Fibers) Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

Refer to above specifications.

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripes

Arid-Core Stranded Loose Tube Armored Cable


(72 Fiber Version Shown)
PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.5 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Binder Ripcord (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F16

Outside Plant Arid-Core Stranded Loose Tube Cable

Non-Armored, All-Dielectric

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS) Lightweight, small design is installer-preferred due to ease of handling
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ 2 - 60 Fibers 62 - 72 Fibers

O-XXX-LN-XY-F12NS/25T O-XXX-LN-XY-F12NS/25T

5 6

0.40/10.2 0.42/10.5

6.0/15.3 6.2/15.8

4.0/10.2 4.2/10.5

607/2700 607/2700

180/800 180/800

48 52

71 78

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

O-XXX-LN-XY-F12NS/25T O-XXX-LN-XY-F12NS/25T O-XXX-LN-XY-F12NS/25T O-XXX-LN-XY-F12NS/25T O-XXX-LN-XY-F12NS/25T

8 10 12 18 24

0.48/12.1 0.54/13.7 0.62/15.8 0.62/15.8 0.72/18.2

7.2/18.2 8.1/20.6 9.3/23.7 9.3/23.7 10.7/27.3

4.8/12.1 8.1/13.7 6.2/15.8 6.2/15.8 7.2/18.2

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

69 89 114 102 138

103 133 170 153 206

Singlemode/Multimode O-XXX-LN-CM-F12NS/25T/AAaaa/BBbbb Composite (4-288 Fibers) Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

Refer to above specifications.

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripes

Arid-Core Stranded Loose Tube Non-Armored, All-Dielectric Cable


(72 Fiber Version Shown)
PE Outer Jacket Water Swellable Tape 2.5 mm Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F17

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Multi-Jacketed Stranded Loose Tube Cable


Double Jacketed, Single Armored

Fiber Optic Cable Products

Jacket/Armor Combinations for Buried/Underground/Aerial Applications


Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)

Product Type/ Fiber Count

Catalog Number

Sub Units

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load lbs/meters Short Term Long Term

Weight lbs/ kg/ kft km

Double Jacket/ Single Armor 2 - 60 Fibers

O-XXX-L2-XY-F12NS/25T 5

0.59/15.0

8.8/22.4

5.9/15.0

607/2700

180/800

132

196

62 - 72 Fibers 74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

O-XXX-L2-XY-F12NS/25T O-XXX-L2-XY-F12NS/25T

6 8

0.60/15.3

9.0/23.0

6.0/15.3 6.7/16.9 7.3/18.5 8.1/20.6 8.1/20.6 9.0/22.9

607/2700 607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800 180/800

138 164 195 232 220 272

205 245 290 345 327 404

0.67/16.9 10.0/25.3 0.73/18.5 10.9/27.7 0.81/20.6 12.1/30.8 0.81/20.6 12.1/30.8 0.90/22.9 13.6/34.4

O-XXX-L2-XY-F12NS/25T 10 O-XXX-L2-XY-F12NS/25T 12 O-XXX-L2-XY-F12NS/25T 18 O-XXX-L2-XY-F12NS/25T 24

Singlemode/Multimode O-XXX-L2-CM-F12NS/25T/AAaaa/BBbbb Composite (4-288 Fibers)


*Other jacket/armor configurations available upon request.

Refer to above specifications.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Double Jacket/Single Armor Loose Tube Cable


(72 Fiber Version Shown)
PE Outer Jacket Ripcord (2) Steel Tape Armoring Water Blocking Tape Binder 2.5 mm Buffer Tubes PE Inner Jacket Dielectric Strength Member 250 Micron Fibers Water Blocking Tape Strength Elements Ripcord (1)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105; RUS/RDUP CFR 1755.902 RD Telecommunications Program Listed

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F18

Outside Plant Arid-Core Mini Stranded Loose Tube Cable

Armored

Fiber Optic Cable Products

Jacket/Armor Combinations for Buried/Underground/Lashed Aerial Applications


Very small 2.0 mm buffer tubes improve kink resistance and facilitate route management in closures Lightweight, small design is installer-preferred due to ease of handling Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Smaller form factor cable can be utilized for tight duct spaces Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ Single Armor 2 - 72 Fibers 74 - 96 Fibers

O-XXX-LA-XY-FZZNS/20T O-XXX-LA-XY-FZZNS/20T

6 8

0.43/10.8 0.48/12.1

6.4/16.2 7.2/18.2

4.3/10.8 4.8/12.1

607/2700 607/2700

180/800 180/800

79 92

117 137

98 - 120 Fibers 122 - 144 Fibers

O-XXX-LA-XY-FZZNS/20T O-XXX-LA-XY-FZZNS/20T

10 12

0.52/13.1 0.58/14.6

7.8/19.7 8.6/22.0

5.2/13.1 5.8/14.6

607/2700 607/2700

180/800 180/800

108 134

160 200

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Mini-Diameter Stranded Loose Tube Cable


(72 Fiber Armored Version Shown)
PE Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Water Blocking Gel Dielectric Strength Member Strength Elements 250 Micron Fiber Binder Ripcord (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression (Armored) Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 140F (+70 C) FOTP-81; IEC 60794-1-2, Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

F19

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Arid-Core Mini Stranded Loose Tube Cable

Non-Armored, All-Dielectric

Fiber Optic Cable Products

For Buried/Underground/Lashed Aerial Applications


Lightweight, small design is installer-preferred due to ease of handling Smaller form factor cable which can be utilized for tight duct space requirements Small and flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitates route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ 2 - 72 Fibers 74 - 96 Fibers

O-XXX-LN-XY-F12NS/20T

0.37/9.5

5.6/14.3

3.7/9.5

607/2700

180/800

48

72

O-XXX-LN-XY-F12NS/20T

0.41/10.5

6.2/15.7

4.1/10.5

607/2700

180/800

58

86

98 - 120 Fibers 122 - 144 Fibers

O-XXX-LN-XY-F12NS/20T O-XXX-LN-XY-F12NS/20T

10 12

0.46/11.8 0.52/13.3

6.9/17.6 7.8/19.9

4.6/11.8 5.2/13.3

607/2700 607/2700

180/800 180/800

71 92

106 138

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Arid-Core Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable


(72 Fiber Version Shown)
PE Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F20

Indoor/Outdoor LSZH Arid-Core Mini Stranded Loose Tube Cable

Low-Smoke Zero-Halogen, Armored

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a LSZH Rating

Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors Corrugated steel armor is strong yet flexible providing additional crush and rodent protection
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ 2 - 72 Fibers 74 - 96 Fibers

Z-XXX-LA-XY-F12BK/20G

0.48/12.3

7.3/18.5

4.8/12.3

607/2700

180/800

123

183

Z-XXX-LA-XY-F12BK/20G

0.54/13.6

8.0/20.4

5.4/13.6

607/2700

180/800

143

213

98 - 120 Fibers 122 - 144 Fibers

Z-XXX-LA-XY-F12BK/20G Z-XXX-LA-XY-F12BK/20G

10 12

0.58/14.6 0.64/16.1

8.6/21.9 9.5/24.2

5.8/14.6 6.4/16.1

607/2700 607/2700

180/800 180/800

166 201

248 300

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

LSZH Arid Core Mini Stranded Loose Tube Armored Cable


(72 Fiber Version Shown)
LSZH Outer Jacket Steel Tape Armoring Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Ripcord (1) Binder

Flame Test Specifications


Flame Test Listing Flame Test Standard NEC Type: OFNR-LS (ETL) and c(ETL) UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383

Environmental Specifications
Installation Temperature -22 to +158F (-30 to +70C) Operating Temperature -40 to +158F (-40 to +70C) Storage Temperature
Test

-40 to +167F (-40 to +75C)


Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105

Specifications are subject to change without notice.

F21

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Indoor/Outdoor LSZH Mini Stranded Loose Tube Cable


Low-Smoke Zero-Halogen, Non-Armored, All-Dielectric

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a LSZH Rating


Helps eliminate transition splicing at the building entrance Lightweight, small design is installer-preferred due to ease of handling Flexible 2.0mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management UV-resistant jacket suitable for use outdoors
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Single Jacket/ 2 - 72 Fibers 74 - 96 Fibers

Z-XXX-LN-XY-F12BK/20G

0.43/11.0

6.5/16.5

4.3/11.0

607/2700

180/800

85

127

Z-XXX-LN-XY-F12BK/20G

0.47/12.0

7.1/18.0

4.7/12.0

607/2700

180/800

101

151

98 - 120 Fibers 122 - 144 Fibers

Z-XXX-LN-XY-F12BK/20G Z-XXX-LN-XY-F12BK/20G

10 12

0.52/13.3 0.58/14.7

7.8/19.9 8.7/22.0

5.2/13.3 5.8/14.7

607/2700 607/2700

180/800 180/800

123 151

183 225

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

LSZH Mini Stranded Loose Tube Non-Armored, All-Dielectric Cable


(72 Fiber Version Shown)
LSZH Outer Jacket Water Swellable Tape 2.0 mm Gel Filled Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fibers Binder Ripcord (1)

Flame Test Specifications


Flame Test Listing Flame Test Standard NEC Type: OFNR-LS (ETL) and c(ETL) UL-1666, UL-1685, IEC 60332-3, IEC 61034-2; IEC 60754-2, IEEE 383

Environmental Specifications
Installation Temperature -22 to +158F (-30 to +70C) Operating Temperature -40 to +158F (-40 to +70C) Storage Temperature
Test

-40 to +167F (-40 to +75C)


Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-20-CORE Issue 2; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F22

Outside Plant Stranded Loose Tube Cable


High Density Loose Tube

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Flexible buffer tubes improve kink resistance, reduce bend sensitivity and facilitates route management in closures Eliminates the need for ribbonized fibers by giving you a compact cable with up to 576 loose fibers
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Armored 290-432 Fibers

O-XXX-LA-XY-F24NS

18

0.90/22.9

13.5/34.3

9.0/22.9

607/2700

180/800

241

358

434-576 Fibers All Dielectric 290-432 Fibers 434-576 Fibers Double Jacketed Single Armored 290-432 Fibers 434-576 Fibers

O-XXX-LA-XY-F24NS O-XXX-LN-XY-F24NS O-XXX-LN-XY-F24NS O-XXX-L2-XY-F24NS O-XXX-L2-XY-F24NS

24 18 24 18 24

1.03/26.2 0.85/21.5 0.98/24.8 1.02/25.9 1.15/29.2

15.4/39.2 12.7/32.2 14.6/37.2 15.3/38.9 17.3/43.8

10.3/26.2 607/2700 8.5/21.5 9.8/24.8 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

310 173 233 337 423

461 258 347 501 630

10.2/25.9 607/2700 11.5/29.2 607/2700

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

All-Dielectric High Density Loose Tube Fiber Cable


(432 Fiber Version Shown)
PE Outer Jacket Strength Elements 3.5 mm Gel Filled Buffer Tube Dielectric Strength Member Fiber Binder Threads Water Swellable Tape 250 Micron Optical Fibers Ripcord (1)

Subunit Detail

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression (dielectric) Compression (armored) Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F23

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

ADSS Short Span Loose Tube Cable


For Aerial Long Haul and Metro Applications

All-Dielectric, Self-Supporting (ADSS) Aerial Design

Fiber Optic Cable Products

Small cable diameter and bend radius for lightweight and ease of handling and installation Designed for aerial spans requiring a self-supporting, non-messengered product Single Medium Density Polyethylene (MDPE) jacket for fast convenient cable preparation Fully qualified in accordance with Telcordia Technologies, EIA/TIA and IEEE Standards
Product Type/ Fiber Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm lbs/newtons Maximum Tensile Load Short Term Long Term kft km Weight l bs/ kg/ kft km

Single Jacket 2-60 Fibers

S-XXX-LN-XY-F12NS/NFB

0.46/11.8

7.0/17.7

4.6/11.8 960/4270 775/3447

66

99

Other ADSS designs are available upon request.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Custom Sag & Tension Tables are available upon request. ADSS Double Jacket Loose Tube All-Dielectric Cable
(60 Fiber Version Shown)
PE Outer Jacket Aramid Strength Elements 3.0mm Gel-Filled Buffer Tube Dielectric Strength Member Water Swellable Tape Ripcord (1) Binder 250 Micron Fibers

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F24

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube Armored

Fiber Optic Cable Products

For Aerial Applications


Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Weight lbs/ kg/ kft km

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable OD inch/mm

Cable Height inch/cm

Messenger Jacket. OD

Figure-8 Armored 2 - 60 Fibers

M-XXX-LA-XY-F12NS/ 25D

0.47/11.9

0.89/22.5 0.33/8.3

7.0/17.8

4.7/11.9

230

342

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Armored Cable


(60 Fiber Version Shown)
MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Binder Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

F25

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube Non-Armored
For Aerial Applications
Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Uses standard figure-8 cable hardware and installation practices 100% gel-free stranded loose tube cable reduces cable prep time Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip

Fiber Optic Cable Products

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable Outer Diameter inch/mm

Cable Height inch/cm

Messenger Jacket OD inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Weight lbs/ kg/ kft km

Figure-8 Non-Armored 2 - 60 Fibers

M-XXX-LN-XY-F12NS/ 25D

0.41/10.5

0.85/21.7 0.33/8.3

16.5/42.0

8.2/21.0

200

299

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Self-Supporting Non-Armored Cable


(60 Fiber Version Shown)
MDPE Outer Jacket Stranded 0.25 Flooded Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

Water Swellable Tape Binder Strength Elements 2.5 mm Gel-Free Buffer Tube Dielectric Strength Member 250 Micron Fiber Ripcord Binder

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F26

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube Armored

Fiber Optic Cable Products

For Aerial Applications


Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Uses standard figure-8 cable hardware and installation practices

Product Type/ Fiber Count

Catalog Number

Sub Units

Cable Outer Diameter inch/mm

Cable Height inch/cm

Messenger Jacket OD inch/cm

Minimum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Armored 2 - 60 Fibers

M-XXX-LA-XY-F12NS

0.51/13.0

0.95/24.2

0.35/8.9

7.7/19.4

5.1/13.0

251

373

62 - 72 Fibers 74 - 144 Fibers 146 - 216 Fibers 218-288 Fibers

M-XXX-LA-XY-F12NS M-XXX-LA-XY-F12NS M-XXX-LA-XY-F12NS M-XXX-LA-XY-F12NS

6 12 18 24

0.55/14.0 0.79/20.2 0.79/20.2 0.91/23.2

0.99/25.1 1.24/31.4 1.24/31.4 1.35/34.4

0.35/8.9 0.35/8.9 0.35/8.9 0.35/8.9

8.2/20.9 11.9/30.3 11.9/30.3 13.7/34.7

5.5/14.0 7.9/20.2 7.9/20.2 9.1/23.2

267 372 357 424

397 554 531 633

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Armored Cable


(72 Fiber Version Shown)
MPDE Outer Jacket Stranded 0.25 Galvanized Steel Messenger Steel Tape Armoring Binder Water Swellable Tape 3.0 mm Gel Filled Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

F27

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube Non-Armored
For Aerial Applications
Figure-8 cable design allows easy, one-step installation resulting in cost savings Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Standard color-coding on fibers and buffer tubes helps ease installation All buffer tubes are constructed to a nominal OD of 3mm reducing the number of tools required in the field Uses standard figure-8 cable hardware and installation practices

Fiber Optic Cable Products

Product Type/ Fiber Count

Catalog Number

Sub Units

Cable Outer Diameter inch/mm

Cable Height inch/cm

Messenger Jacket OD inch/cm

Minimum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Non-Armored 2 - 60 Fibers

M-XXX-LN-XY-F12NS

0.46/11.6

0.90/22.8

0.35/8.9

6.8/17.4

4.6/11.6

214

318

2 - 72 Fibers 74 - 144 Fibers 146 - 216 Fibers 218-288 Fibers

M-XXX-LN-XY-F12NS M-XXX-LN-XY-F12NS M-XXX-LN-XY-F12NS M-XXX-LN-XY-F12NS

6 12 18 24

0.50/12.6 0.74/18.8 0.74/18.8 0.86/21.8

0.94/23.8 1.18/30.0 1.18/30.0 1.30/33.0

0.35/8.9 0.35/8.9 0.35/8.9 0.35/8.9

7.4/18.9 11.1/28.2 11.1/28.2 12.9/32.7

5.0/12.6 7.4/18.8 7.4/18.8 8.6/21.8

227 313 298 349

338 466 443 520

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Non-Armored Cable


(72 Fiber Version Shown)
MDPE Outer Jacket Stranded 0.25 Galvanized Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

Water Swellable Tape Binder Strength Elements 3.0 mm Gel-Filled Buffer Tube Dielectric Strength Member 250 Micron Fiber Binder Ripcord Binder

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F28

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube Armored

Fiber Optic Cable Products

For Aerial Applications


100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable Outer Diameter inch/mm

Cable Height inch/mm

Messenger Jacket OD inch/mm

Maximum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Armored 2 - 60 Fibers

M-XXX-LA-XY-F12NS/ 25D/188

0.47/11.9

0.83/21.1

0.27/6.9

7.0/17.8

4.7/11.9

180

267

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Armored Cable


(60 Fiber Version Shown)
MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger Steel Tape Armoring Binder Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140F (+70C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

F29

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube, Non-Armored
For Aerial Applications
100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip

Fiber Optic Cable Products

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable Outer Diameter inch/mm

Cable Height inch/mm

Messenger Jacket OD inch/mm

Maximum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Non-Armored 2 - 60 Fibers

M-XXX-LN-XY-F12NS/ 25D/188

0.41/10.5

0.78/19.7

0.27/6.9

6.2/15.8

4.1/10.5

146

217

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Non-Armored Cable


(60 Fiber Version Shown)
MPDE Outer Jacket Stranded 3/16 Galvanized Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Binder Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Compression Flex Impact Strain Twist Water Penetration


Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F30

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube, Armored

Fiber Optic Cable Products

For Aerial Applications


100% gel-free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable Outer Diameter inch/mm

Cable Height inch/mm

Messenger Jacket OD inch/mm

Maximum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Armored 2 - 60 Fibers

M-XXX-LA-XY-F12NS/ 25D/109

0.47/11.9

0.75/19.2

0.20/5.0

7.0/17.8

4.7/11.9

124

185

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Armored Cable


(60 Fiber Version Shown)
MPDE Outer Jacket 0.109 Galvanized Steel Messenger Steel Tape Armoring Binder Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

F31

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Self-Supporting Figure-8 Cable


Messengered Stranded Loose Tube, Non-Armored
For Aerial Applications
100% gel free stranded loose tube cable reduces cable prep time Smaller, more flexible messenger for shorter spans, facilitating a lower cost alternative Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip

Fiber Optic Cable Products

Product Type/ Fiber Count

Catalog Number

Buffer Tubes

Cable Outer Diameter inch/mm

Cable Height inch/mm

Messenger Jacket OD inch/mm

Maximum Bend Radius Loaded Unloaded inch/cm lbs/newtons

Weight lbs/ kg/ kft km

Figure-8 Non-Armored 2 - 60 Fibers

M-XXX-LN-XY-F12NS/ 25D/109

0.41/10.5

0.70/17.8

0.20/5.0

6.2/15.8

4.1/10.5

90

134

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Non-Armored Cable


(60 Fiber Version Shown)
MPDE Outer Jacket 0.109 Galvanized Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Binder Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member 250 Micron Fibers Strength Elements Ripcord (1) Binder

Compression Flex Impact Strain Twist Water Penetration


Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F32

Indoor/Outdoor Stranded Loose Tube Cable


Riser-Rated

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a Riser Rating


All meet critical NEC/CEC riser (OFNR) safety standards, eliminating the need for splice point at building entrance 100% gel free stranded loose tube cable reduces cable prep time Lightweight, small design is installer-preferred due to ease of handling Flexible 2.5mm buffer tubes improve kink resistance, reduce bend sensitivity, and facilitate route management in closures
Product Type/ Fiber Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term Weight lbs/ kg/ kft km

Single Jacket 2 - 60 Fibers 62 - 72 Fibers

R-XXX-LN-XY-F12BK/25D R-XXX-LN-XY-F12BK/25D

5 6

0.45/11.5 0.47/11.9

6.8/17.3 7.1/17.9

4.5/11.5 4.7/11.9

607/2700 607/2700

180/800 180/800

79 85

118 127

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

R-XXX-LN-XY-F12BK/25D R-XXX-LN-XY-F12BK/25D R-XXX-LN-XY-F12BK/25D R-XXX-LN-XY-F12BK/25D R-XXX-LN-XY-F12BK/25D

8 10 12 18 24

0.53/13.5 0.59/15.1 0.68/17.2 0.70/17.8 0.79/20.2

8.0/20.3 8.9/22.6 10.1/25.7 10.5/26.7 11.9/30.2

5.3/13.5 5.9/15.1 6.8/17.2 7.0/17.8 7.9/20.2

607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800

109 130 176 162 208

161 193 262 240 309

Singlemode/Multimode R-XXX-LN-XY-F12BK/25D/AAaaa/BBbbb Composite (4-288 Fibers)

Refer to above specifications.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable


(72 Fiber Version Shown)
PVC Outer Jacket Water Swellable Tape 2.5 mm Gel Free Buffer Tube Dielectric Strength Member Strength Element 250 Micron Fiber Binder Ripcord Binder

Flame Test Specifications


Flame Test Listing Flame Test Standard Installation Temperature Operating Temperature Storage Temperature
Test

NEC Type OFNR (ETL) and c(ETL) UL-1666 -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Environmental Specifications

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105

F33

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Indoor/Outdoor Stranded Loose Tube Cable


Plenum-Rated

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a Plenum Rating


Combines application spaces of building interconnect and plenum in a campus environment Dielectric design is lightweight, easy to access and does not require grounding 100% gel-free stranded loose tube cable reduces cable prep time Water blocking prevents moisture migration Temperature range is fully outside plant rated
Product Type/ Fiber Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term lbs/ kft Weight kg/ km

Single Jacket 2 - 60 Fibers 61 - 72 Fibers

P-XXX-LN-XY-F12BK/25D P-XXX-LN-XY-F12BK/25D P-XXX-LN-XY-F12BK/25D P-XXX-LN-XY-F12BK/25D P-XXX-LN-XY-F12BK/25D

5 6 8 10 12

0.38/9.7 0.40/10.1 0.46/11.7 0.52/13.3 0.60/15.3

5.7/14.6 6.0/15.2 6.9/17.5 7.8/19.9 9.1/23.0

3.8/9.7 4.0/10.1 4.6/11.7 5.2/13.3 6.0/15.3

600/2700 600/2700 600/2700 600/2700 600/2700

180/800 180/800 180/800 180/800 180/800

64 71 95 124 168

96 105 142 185 250

74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers

Singlemode/Multimode P-XXX-LN-CM-F12BK/25D/AAaaa/BBbbb Refer to above specifications. Composite (4-144 Fibers) Variables in the Catalog Number:
XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable


(72 Fiber Version Shown)
Plenum-Rated Outer Jacket Water Swellable Tape 2.5mm Gel Free Buffer Tubes Dielectric Strength Member Strength Elements 250 Micron Fiber Binder Ripcord (1) Binder

Flame Test Specifications


Flame Test Listing Flame Test Standard Installation Temperature Operating Temperature Storage Temperature
Test

NEC Type OFNP (ETL) and c(ETL) NFPA-262 -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Environmental Specifications

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F34

Indoor/Outdoor FiberGuard Stranded Loose Tube Cable


TM

Riser-Rated

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a Riser Rating


Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket NEC/CEC compliant Outstanding mechanical protection for sensitive cables combined with excellent flexibility
Product Type/ Fiber Count Catalog Number Buffer Tubes Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term Weight lbs/ kg/ kft km

2 - 60 Fibers

R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D R-XXX-LZ-XY-FZZBK/25D

5 6 8 10 12 18 24

0.81/20.5 0.81/20.5 0.86/21.7 0.91/23.0 1.01/25.5 1.06/26.8 1.11/28.1

16.1/40.9 16.1/40.9 17.1/43.5 18.1/46.0 20.1/51.1 21.1/53.6 22.1/56.2

11.3/28.6 300/1335 11.3/28.6 300/1335 12.0/30.4 300/1335 12.7/32.2 300/1335 14.1/35.7 300/1335 14.8/37.5 300/1335 15.5/39.3 300/1335

90/400 90/400 90/400 90/400 90/400 90/400 90/400

215 221 254 285 329 323 378

320 328 378 424 489 481 563

62 - 72 Fibers 74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers 146 - 216 Fibers 218 - 288 Fibers

Singlemode/Multimode R-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Composite (4-288 Fibers)

Refer to above specifications.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Riser-Rated Indoor/Outdoor Stranded Loose Tube Cable


(72 Fiber Version Shown)
Riser-Rated Outer Jacket Interlocking Aluminum Armor Riser-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber Binder 2.5 mm Gel Free Buffer Tubes Ripcord(1)

Flame Test Specifications


Flame Test Listing Flame Test Standard Installation Temperature Operating Temperature Storage Temperature
Test

NEC Type OFCR (ETL) and c(ETL) UL-1666 -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Environmental Specifications

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

483 lbf/in (85 N/mm) 25 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105

F35

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Indoor/Outdoor FiberGuard Stranded Loose Tube Cable


TM

Plenum-Rated

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a Plenum Rating


Cables are protected with an interlocking armor to shield against damage Well suited for construction and renovations, heavy industry and high security area applications Aluminum interlocking armor with overall jacket 100% gel-free stranded loose tube cable reduces cable prep time Outstanding mechanical protection for sensitive cables combined with excellent flexibility
Product Type/ Fiber Count Catalog Number Buffer Tubes Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term Weight lbs/ kg/ kft km

2 - 60 Fibers

P-XXX-LZ-XY-FZZBK/25D P-XXX-LZ-XY-FZZBK/25D P-XXX-LZ-XY-FZZBK/25D P-XXX-LZ-XY-FZZBK/25D P-XXX-LZ-XY-FZZBK/25D

5 6 8 10 12

0.71/17.9 0.71/17.9 0.81/20.5 0.86/21.7 0.96/24.3

14.1/35.8 14.1/35.8 16.1/40.9 17.1/43.5 19.1/48.5

9.9/25.1 9.9/25.1

300/1335 300/1335

90/400 90/400 90/400 90/400 90/400

192 199 245 285 330

286 296 365 425 491

62 - 72 Fibers 74 - 96 Fibers 98 - 120 Fibers 122 - 144 Fibers

11.3/28.6 300/1335 12.0/30.4 300/1335 13.4/34.0 300/1335

Singlemode/Multimode P-XXX-LZ-XY-FZZBK/25D/AAaaa/BBbbb Composite (4-288 Fibers)

Refer to above specifications.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-24 repeat color sequence with tracer stripe

Plenum-Rated Indoor/Outdoor Stranded Loose Tube Cable


(72 Fiber Version Shown)
Plenum-Rated Outer Jacket Interlocking Aluminum Armor Plenum-Rated Inner Jacket Strength Elements Water Swellable Tape Dielectric Strength Member 250 Micron Fiber Binder 2.5 mm Gel Free Buffer Tubes Ripcord(1)

Flame Test Specifications


Flame Test Listing Flame Test Standard Installation Temperature Operating Temperature Storage Temperature
Test

NEC Type OFCP (ETL) and c(ETL) NFPA-262 -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Environmental Specifications

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

483 lbf/in (85 N/mm) 25 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) FOTP-98 N/A N/A -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F36

Outside Plant Central Tube Cable


Armored and All-Dielectric Designs

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


Robust constructions offer excellent protection of fibers Provides easy access to the fibers Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort

Product Type/ Fiber Count

Catalog Number

Subunits

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons

Weight lbs/ kg/ kft km

Armored 2-24 Fibers, 4mm Tube

O-XXX-CA-XY-F12NS

2 4

0.43/11.0 0.51/13.0

6.5/16.5 7.7/19.5

4.3/11.0 607/2700 5.1/13.0 607/2700

180/800 180/800

91 118

135 176

26-48 Fibers, 6mm Tube O-XXX-CA-XY-F12NS

All-Dielectric 2-24 Fibers, 4mm Tube

O-XXX-CN-XY-F12NS

2 4

0.40/10.1 0.48/12.1

5.9/15.1 7.2/18.2

4.0/10.1 607/2700 4.8/12.1 607/2700

180/800 180/800

63 86

94 128

26-48 Fibers, 6mm Tube O-XXX-CN-XY-F12NS

Singlemode/Multimode Composite (4-48 Fibers)

O-XXX-CA-CM-F12NS/AAAaa/BBbbb Refer to above specifications. O-XXX-CN-CM-F12NS/AAaaa/BBbbb (Tube size will vary depending on fiber count/configuration.)

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Central Tube Armored Cable


(24 Fiber Version Shown)
Steel RSM (2) Ripcord for Armor Access (2) PE Outer Jacket Gel 4.0 mm Buffer Tube Fiber Binder Thread 250 Micron Fibers Steel Armor Ripcord for Jacket Access (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression (Dielectric) Compression (Armored) Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Central Tube Non-Armored All-Dielectric Cable


(36 Fiber All-Dielectric Version Shown)
Rigid RSM (2) PE Outer Jacket Water-Blocking Tape Gel 6.0 mm Buffer Tube Fiber Binder Threads 250 Micron Fibers Ripcord for Jacket Access (2)

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +70 (+140 C) FOTP-81; IEC 60794-102, Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F37

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Indoor/Outdoor Central Tube Cables


Riser-Rated

Fiber Optic Cable Products

For Indoor/Outdoor Applications that Require a Riser Rating


All meet critical NEC/CEC riser (OFNR) safety standards eliminating the need for splice point at building entrance Arid-Core water blocking technology helps protect fibers from moisture Standard color-coding on fibers helps ease installation Robust constructions offer excellent protection of fibers

Product Type/ Fiber Count

Catalog Number

Sub Units

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load lbs/meters Short Term Long Term

Weight lbs/ kg/ kft km

Single Jacket 2-24 Fibers, 4mm Tube R-XXX-CN-XY-F12BK

0.40/10.1

5.9/15.1

4.0/10.1

607/2700

180/800

87

129

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Indoor/Outdoor Central Tube Cable


(24 Fiber Version Shown)
Rigid RSM (2) PVC Outer Jacket Flexible Strength Elements Gel 4.0mm Buffer Tube 250 Micron Fibers Fiber Binder Threads Ripcord for Jacket Access (2)

Flame Test Specifications


Flame Test Listing Flame Test Standard Installation Temperature Operating Temperature Storage Temperature
Test

NEC Type OFNR (ETL) and c(ETL) UL-1666 -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Environmental Specifications

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant See long & short tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle +28 F (-2 C) FOTP-98 +140 F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-104-696-2001; Telcordia GR-409-CORE Issue 2; EN 187105

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F38

Outside Plant Drop Cable


Armored Design

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination (no preferential bend) Cost effective, low fiber count cable for outside plant applications Corrugated steel tape armor is strong yet flexible providing additional crush and rodent protection Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)

Product Type/ Fiber Count

Catalog Number

Subunits

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons

Weight lbs/ kg/ kft km

Armored 1-12 Fibers

O-XXX-DA-XY-F12NS

0.32/8.1

4.8/12.2

3.2/8.1

300/1334

90/400

47

70

Singlemode/Multimode O-XXX-DA-CM-F12NS/AAaaa/BBbbb Composite (4-12 Fibers)

Refer to above specifications.

*This design is also available with a ripcord for applications where mid-span access is important (O-XXX-DA-XY-F12NS/BP) Variables in the Catalog Number:
XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend Insensitive, Singlemode Fiber*

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F a minimum bend radius of 5X the cable diameter ,

Drop Armored Cable


(12 fiber version shown)
MDPE Outer Jacket Steel Armor Fiberglass Strength Elements 3.0mm Buffer Tube Aramid Strength Elements Gel 250 Micron Fibers

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours


Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

F39

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Drop Cable


All-Dielectric Design

Fiber Optic Cable Products

For Buried/Underground/Aerial Applications


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications An outstanding choice when space is at a premium Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip

Product Type/ Fiber Count

Catalog Number

Subunits

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons

Weight lbs/ kg/ kft km

All-Dielectric 1 - 12 Fibers

O-XXX-DN-XY-F12NS

0.34/8.7

5.1/13.0

3.4/8.7

300/1334

90/400

46

69

Singlemode/Multimode O-XXX-DN-CM-F12NS/AAaaa/BBbbb Composite (4-12 Fibers)

Refer to above specifications.

Variables in the Catalog Number:

XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend-Insensitive, Singlemode Fiber*

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F a minimum bend radius of 5X the cable diameter ,

All-Dielectric Drop Cable


(12 fiber version shown)
PE Outer Jacket Rigid RSM (2) Strength Elements 3.0 mm Buffer Tube Gel 250 Micron Fibers

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F40

Self-Support Non-Armor Figure-8 Outdoor Drop Cable


1 - 6 Fiber Arid-Core Construction

Fiber Optic Cable Products

For Aerial Applications


Cost effective, low fiber count cable for outside plant applications Figure-8 cable designed for extended span capability Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed Fiber leg was designed to function as a self-sufficient cable once separated from the messenger
Product Type/ Fiber Count Catalog Number Diameter Over Messenger inch/mm Cable Height inch/mm Diameter Over Fiber inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Max Tensile Load Weight Short Term Long Term lbs/ kg/ Lbs/N Lbs/N kft km

Figure-8 Drop 1 - 6 Fibers

M-XXX-MN-XY-FZZNS/ 25G/109

0.17/4.3

0.42/10.7

0.20/5.1

3.0/7.7

2.0/5.1

300/1334

90/400 52

77

Variables in the Catalog Number:

XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend-Insensitive, Singlemode Fiber*

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F a minimum bend radius of 5X the cable diameter ,

Figure-8 Drop Cable


(6 fiber version shown)
Low Density Polyethylene Outer Jacket 0.109 Solid Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression 57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Strength Elements 2.5 mm Gel Filled Buffer Tube 250 Micron Fibers Rigid Strength Elements Ripcord (1)

Flex Impact Strain Twist Water Penetration


Test

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

F41

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant Self-Supporting Figure-8 Drop Cable


1 - 12 Fiber Arid-Core Construction
For Aerial Applications
Small, lightweight cable allowing for increased ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Medium Density Polyethylene (MDPE) jacket is rugged, durable and easy to strip Solid steel messenger member for simplified aerial applications Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)
Product Type/ Fiber Count Catalog Number Diameter Over Messenger inch/mm Cable Height inch/mm Diameter Over Fiber inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Max Tensile Load Weight Short Term Long Term lbs/ kg/ Lbs/N Lbs/N kft km

Fiber Optic Cable Products

Figure-8 Drop 1 - 12 Fibers

M-XXX-DN-XY-FZZNS/ GSM/40T

0.13/3.4

0.45/11.5

0.27/6.8

4.0/10.2

2.7/6.8

300/1334

90/400 47

69

Variables in the Catalog Number:

XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend-Insensitive, Singlemode Fiber*

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F a minimum bend radius of 5X the cable diameter ,

Figure-8 Drop Cable


(2 fiber version shown)
MDPE Outer Jacket 0.083 Messenger Wire

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

Strength Elements Ripcord (1) 4.0 mm Buffer Tube Gel 250 Micron Fibers

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours


Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F42

Outside Plant Self-Supporting Figure-8 Mini-Drop Cable


1 - 6 Fiber Arid-Core Construction Copper Clad Steel Messenger

Fiber Optic Cable Products

For Underground/Conduit Applications


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Small, lightweight cable increases ease of installation, routing and termination Cost effective, low fiber count cable for outside plant applications Solid steel messenger member can be used for toning Flexible design allows ease of routing and placement Rural Development Utilities Program (RDUP) listed, a program administered by the Rural Utilities Service (RUS)

Product Type/ Fiber Count

Catalog Number

Diameter Over Messenger inch/mm

Cable Height inch/mm

Diameter Over Fiber inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Max Tensile Load Weight Short Term Long Term lbs/ kg/ Lbs/N Lbs/N kft km

Figure-8 Drop 1 - 12 Fibers

M-XXX-MN-XY-F12NS/ CCS

0.16/4.0

0.36/9.0

0.15/3.8

2.2/5.6

1.5/3.8

300/1334

90/400 26

39

Variables in the Catalog Number:

XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8F Bend-Insensitive, Singlemode Fiber*

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Identification Threads/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua *CommScope offers bend-insensitive, ITU-T G.657.A compliant singlemode fiber (CommScope Type 8F). When using Fiber Type 8F a minimum bend radius of 5X the cable diameter ,

Figure-8 Mini-Drop Cable


(6 fiber version shown)
Linear Low Density Polyethylene Outer Jacket Solid Steel Messenger

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


2.5mm Gel Filled Buffer Tube 250 Micron Fibers

Compression Flex Impact Strain Twist Water Penetration


Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours


Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

F43

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Outside Plant All-Dielectric Flat Drop Cable


For Aerial Applications

1 - 12 Fiber Arid-Core Construction Aerial Self-Support or Direct Burial

Fiber Optic Cable Products

All dielectric cable design, which requires no bonding or grounding Compatible with industry standard hanging hardware Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination
Product Type/ Fiber Count Catalog Number Cable Outer Diameter inch/mm Cable Height inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Max. Tensile Window Short Term Long Term lbs/N lbs/N Weight lbs/ kg/ kft km

All-Dielectric Flat Drop 1 - 12 Fibers O-XXX-DF-XY-F12NS

0.32/8.2

0.18/4.5

4.8/12.3

3.2/8.1

300/1334

90/400

28

42

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Mini-Drop Cable


(12 fiber version shown)
MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F44

Outside Plant All-Dielectric Flat Drop Cable


1 - 12 Fiber Arid-Core Construction Aerial Self-Support

Fiber Optic Cable Products

For Underground/Conduit Applications


Incorporated tone wire designed for tone locating when digging Cost effective, low fiber count cable for outside plant applications Small, lightweight cable increases ease of installation, routing and termination Tone wire can be easily separated as needed Medium Density Polyethylene (MDPE) jacket is rugged, durable, and easy to strip
Product Type/ Fiber Count Catalog Number Cable Outer Diameter inch/mm Cable Height inch/mm Msg. Jkt. Outer Dia. inch/mm Minimum Bend Radius Loaded Unloaded inch/mm inch/cm Max. Tensile Window Short Term Long Term inch/cm lbs/N Weight lbs/ kg/ kft km

All-Dielectric Flat Drop 1 - 12 Fibers

O-XXX-DF-HY-F12NS/ XYXXX/1x24AWG

0.40/10.2 0.18/4.5 0.08/2.0 6.0/15.3

3.2/8.1

300/1334

90/400

38

57

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Figure-8 Mini-Drop Cable


(12 fiber version shown)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

24-awg Copper Conductor MDPE Outer Jacket GRP Rods 2.0mm Buffer Tube 250 Micron Fibers Ripcords (2)

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours


Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F ;+70 C FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003 RUS/RDUP 7 CFR 1755.903 RD Telecommunications Program Listed

Specifications are subject to change without notice.

F45

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

LSZH Indoor/Outdoor Cable


Non-Armored, All-Dielectric

Fiber Optic Cable Products

For Indoor/Outdoor Drop Applications that Require a LSZH Rating

Black jackets are UV-stable for outdoor use yet meet critical NEC type safety standards OFNR-LS (ETL) and C(ETL) Also meets many international flame ratings such as IEC 60332-1, IEC 60332-3, IEC 61034-02, IEC 60754-1, IEC 60754-2 and NES 713 Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment

Product Type/ Fiber Count

Catalog Number

Sub Units

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load lbs/meters Short Term Long Term

Weight lbs/ kg/ kft km

Single Jacket 1-12 Fibers

Z-XXX-DN-XY-F12BK/ 20G

0.24/6.1

3.6/9.1

2.4/6.1

300/1334

90/400

30

44

Product Type/ Fiber Count

Catalog Number

Sub Units

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load lbs/meters Short Term Long Term

Weight lbs/ kg/ kft km

Single Jacket 1-24 Fibers

Z-XXX-DN-XY-F12BK

0.33/8.3

4.9/12.5

3.3/8.3

300/1334

90/400

48

72

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

LSZH All-Dielectric Indoor/Outdoor Cable


(12 Fiber, 4.0 mm Tube Version Shown)

Flame Test Specifications


Flame Test Listing Flame Test Standard NEC Type OFNR-LS (ETL) and c(ETL) UL-1666, UL-1685, IEC 60332-3, IEC 61034-2, IEC 60754-2, IEEE 383

FRPE Outer Jacket Fiberglass Strength Elements 4.0 mm Gel Filled Buffer Tube 250 Micron Fibers Ripcord

Environmental Specifications
Installation Temperature -4 to +158F (-20 to +70C) Operating Temperature -4 to +158F (-20 to +70C) Storage Temperature -4 to +167F (-20 to +75C)

Mechanical Test Specifications


Test Requirement Test Method

Compression Flex Impact Strain Twist Water Penetration


Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

+28 F (-2 C) +140 F (+70 C) -4 to +185F (-20 to +85C) -4 to +140F (-20 to +60C) -4 to +158F (-20 to +70C)

FOTP-98 FOTP-81; IEC 60794-1-2; Sec. 17 N/A FOTP-28; IEC 60794-1-2; Sec. 28 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2003

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F46

ConQuest Toneable Conduit

TM

Installed with Central Tube Fiber Optic Products

Fiber Optic Cable Products

Fiber In ConQuest Toneable Conduit Cuts Installation Effort and Costs

High strength 18 gauge copper clad steel tone wire saves installation dollars Moisture resistant polymer coated tone wire accurately detectable over various depths and lengths Tone wire embedded in the wall of the HDPE conduit results in easy wire removal Internally reinforced HDPE wall works with standard conduit connections
Fiber Part Number & Conduit Description Cable OD & Weight (kft) Available Conduit OD Available Wall Thicknesses SDR 11 Weight (lb/kft)* SDR 13.5 SCH 40

Cable Type/ Fiber Count

Central Tube Dielectric 2 - 24 Fibers

O-XXX-CN-XY-F12NS Specify Conduit OD, Wall Thickness and Color

0.40 63 lbs.

1 11/4 11/2 2

SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

265 381 477

230 326 405 593

533

Central Tube Dielectric 26 - 48 Fibers

O-XXX-CN-XY-F12NS Specify Conduit OD, Wall Thickness and Color

0.48 86 lbs.

1 11/4 11/2 2

SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

273 389 485

238 334 413 601

541

Other cables and wall sizes may be available upon request. For more information, please see the Conduit section of this catalog.

* Weight does not include reel.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Central Tube Fiber-In-Conduit


(24 Fiber Construction in Toneable Conduit Shown)

Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Central Tube Cable

Specifications are subject to change without notice.

F47

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

ConQuest Toneable Conduit

TM

Pre-Installed with CommScope Dry Loose Tube Fiber Optic Cable

Fiber Optic Cable Products

Fiber-In-Conduit

All of CommScopes fiber cables can be pre-installed in conduit, including the gel free, Dry Loose Tube cable. Available in five different diameters - 3/4, 1, 11/4, 11/2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com.
Cable Type/ Fiber Count Fiber Part Number & Conduit Description Cable OD & Weight (kft) Available Conduit OD Available Wall Thicknesses SDR 11 Weight (lb/kft)* SDR 13.5 SCH 40

Dry (gel free) Loose Tube Dielectric 2 - 60 Fibers Dry (gel free) Loose Tube Dielectric 62 - 72 Fibers

D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color

0.40 45 lbs.

/ 1 11/4 11/2 2
3 4

SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

175 249 355 461 179 253 369 465

156 214 264 389 577 160 218 314 393 581

517

D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color

0.42 49 lbs.

/ 1 11/4 11/2 2
3 4

521

Dry (gel free) Loose Tube Dielectric 74 - 96 Fibers Dry (gel free) Loose Tube Dielectric 98 - 120 Fibers Dry (gel free) Loose Tube Dielectric 122 - 144 Fibers Dry (gel free) Loose Tube Dielectric 146 - 216 Fibers Dry (gel free) Loose Tube Dielectric 218 - 288 Fibers

D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color D-XXX-LN-XY-F12NS Specify Conduit OD, Wall Thickness and Color

0.48 64 lbs.

/4 1 11/4 11/2 2
3

SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

194 269 384 480 287 403 499 427 523

175 233 329 408 596 252 348 427 615 372 451 639 355 434 622 387 466 654

536

0.54 83 lbs.

1 11/4 11/2 2 1/ 11/2 2


1 4

555

0.62 107 lbs.

579

0.62 90 lbs.

11/4 11/2 2 11/4 11/2 2

410 506

562

0.72 122 lbs.

442 538

594

Other cables and wall sizes may be available upon request.

* Weight does not include reel.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Dry Loose Tube Fiber-In-Conduit


(72 Fiber Construction in Toneable Conduit Shown)
Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Dry Loose Tube Cable * Weight does not include reel. Other cables and wall sizes may be available upon request.

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F48

ConQuest Toneable Conduit

TM

Pre-Installed with CommScope Arid-Core Fiber Optic Cable

Fiber Optic Cable Products

Fiber-In-ConQuest Toneable Conduit Cuts Installation Effort and Costs

All of CommScopes fiber cables can be pre-installed in conduit, including the Arid-Core Loose Tube cable. Available in five different diameters - 3/4, 1, 11/4, 11/2 and 2 and three different wall thicknesses - SDR 11, SDR 13.5 and SCH 40. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com.
Cable Type/ Fiber Count Fiber Part Number & Conduit Description Cable OD & Weight (kft) Available Conduit OD Available Wall Thicknesses SDR 11 Weight (lb/kft)* SDR 13.5 SCH 40

Arid-Core Loose Tube Dielectric 2 - 60 Fibers Arid-Core Loose Tube Dielectric 62 - 72 Fibers

O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color

0.40 48 lbs.

/ 1 11/4 11/2 2
3 4

SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

178 252 368 464 182 256 372 468

159 217 313 392 580 163 221 327 396 584

520

O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color

0.42 52 lbs.

/ 1 11/4 11/2 2
3 4

524

Arid-Core Loose Tube Dielectric 74 - 96 Fibers Arid-Core Loose Tube Dielectric 98 - 120 Fibers Arid-Core Loose Tube Dielectric 122 - 144 Fibers Arid-Core Loose Tube Dielectric 146 - 216 Fibers Arid-Core Loose Tube Dielectric 218 - 288 Fibers

O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color

0.48 69 lbs.

/ 1 11/4 11/2 2
3 4

SDR 11 or 1.35 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR 11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40 SDR11 or 13.5 SDR 11 or 13.5 SDR 13.5 or SCH 40

200 273 389 485 293 409 505 434 530

180 268 334 413 578 258 382 461 649 379 458 646 367 446 634 403 482 670

518

O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color O-XXX-LN-XY-F12NS/25T Specify Conduit OD, Wall Thickness and Color

0.54 89 lbs.

1 11/4 11/2 2 11/4 11/2 2 11/4 11/2 2 11/4 11/2 2

561

0.62 114 lbs.

586

0.62 102 lbs.

422 518

574

0.72 138 lbs.

458 554

610

Other cables and wall sizes may be available upon request.

* Weight does not include reel.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Arid-Core Loose Tube Fiber-In-Conduit


(72 Fiber Construction in Toneable Conduit Shown)
Copper Clad Steel Tone Wire High-Grade Polyethylene Conduit Silicon-Based Lubricant Arid-Core Loose Tube Cable Specifications are subject to change without notice. * Weight does not include reel. Other cables and wall sizes may be available upon request.

F49

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

ConQuest Conduit

Pre-Installed with CommScope Fiber Drop Cable

Fiber Optic Cable Products

Fiber-In-Conduit

All of CommScopes fiber cables can be pre-installed in conduit, including the Fiber Drop cables. Available in 1/2 or 3/4 and two different wall thicknesses - SDR 11 or SDR 13.5. For more information or specifications on Fiber Optic cables, please visit our website at www.commscope.com.

Figure-8 Fiber Drop Cable In Conduit


Cable Type/ Fiber Count Catalog Number (Description) Cable OD & Weight (kft) Available Conduit OD Available Wall Thickness Weight (lb/kft)* SDR 11 SDR 13.5

Fiber Drop Messengered 1 - 6 Fibers

M-XXX-MN-XY-FZZNS/CCS (Solid Steel Construction) Specify Conduit OD, Wall Thickness and Color

0.16 x 0.31 27 lbs.

SDR 11 or 13.5

112 157

98 138

NOTE: The solid or stranded steel messengers can be used to pull the cable during installation, and for locating after burial.

All-Dielectric Flat Drop Cable In Conduit


Cable Type/ Fiber Count Catalog Number (Description) Cable OD & Weight (kft) Available Conduit OD Available Wall Thickness SDR 11 Weight (lb/kft)* SDR 13.5

Flat Drop 1 - 12 Fibers

O-XXX-DF-XY-FZZNS Specify Conduit OD, Wall Thickness and Color

0.18 x 0.32 30 lbs.

SDR 11 or 13.5

115 160

101 141

*Other size conduits may be available upon request.

* Weight does not include reel.

Toneable Flat Drop Cable In Conduit


Cable Type/ Fiber Count Catalog Number (Description) Cable OD & Weight (kft) Available Conduit OD Available Wall Thickness SDR 11 Weight (lb/kft)* SDR 13.5

Toneable Flat Drop 1 - 12 Fibers

O-XXX-DF-HY-FZZNS/XYZZZ/ 1X12AWG Specify Conduit OD, Wall Thickness and Color

0.18 x 0.40 38 lbs.

SDR 11 or 13.5 SDR 11 or 13.6

168 242

149 207

*Other size conduits may be available upon request.

* Weight does not include reel.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

6F 62.5m, FDDI Grade Multimode Fiber 5M LaserCore 150, 50m, Multimode Fiber bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua

Solid Steel Messengered Fiber Drop In ConQuest Conduit (6 Fiber Construction Shown)
High-Grade Polyethylene Conduit Silicon-Based Lubricant Messengered Fiber Drop Cable

All-Dielectric Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown)


High-Grade Polyethylene Conduit Silicon-Based Lubricant

Toneable Flat Drop Cable in ConQuest Conduit (6 Fiber Construction Shown)


High-Grade Polyethylene Conduit Silicon-Based Lubricant

Flat Drop Cable

Toneable Flat Drop Cable

Drawings are not to scale Specifications are subject to change without notice

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F50

CommScope Hybrid Cable


Fiber Optic Cable Products
Features & Benefits

Fiber/6 Series Drop Cable (BrightWire )

The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed
Catalog Number Cable Outer Diameter inch/mm Cable Height inch/mm Component Jacket OD inch/mm Sub Units Minimum Bend Radius Max. Tensile Window Loaded Unloaded Short Term Long Term inch/cm inch/cm lbs/N lbs/N Weight lbs/ kg/ kft km

Product Type/ Fiber Count

1 - 12 Fibers

O-XXX-DN-HY-F12NS/ 0.26/6.6 40G/XYXXX/F6SSBW

0.61/15.4

0.30/7.5

3.9/9.9

2.6/6.6 300/1334 90/400

78

116

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Jacket Color: Black Medium Density Polyethylene

Arid-Core Construction Fiber Coax Hybrid Cable


(12 Fiber Version Shown)
LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape 18 AWG Copper Clad Steel Dielectric Fiberglass Strength Elements 4.0mm Buffer Tube Gel 250 Micron Fibers Ripcord

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2002

Specifications are subject to change without notice.

F51

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

CommScope Self-Support Figure-8 Hybrid Cable


Fiber/6 Series Drop Cable (BrightWire )

Fiber Optic Cable Products

Features & Benefits


The BrightWire drop cable leg is designed to carry video The optical leg is designed to carry voice and data Only a single installation is required Small, very flexible cable allowing for increased ease of installation, routing and termination The legs can be easily separated as needed
Catalog Number Cable Outer Diameter inch/mm Cable Height inch/mm Messenger Jacket OD inch/mm Copper Comp./ Buffer Tubes Minimum Bend Radius Max. Tensile Window Loaded Unloaded Short Term Long Term inch/cm inch/cm lbs/N lbs/N Weight lbs/ kg/ kft km

Product Type/ Fiber Count

1 - 12 Fibers

M-XXX-DN-HY-F12NS/ 0.26/6.6 XYXXX/40T/F6SSBW/ GSM

0.79/20.1

0.13/3.4

1/1

3.9/9.9

2.6/6.6 300/1334 90/400

101 150

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Jacket Color: Black Linear Low Density Polyethylene

Arid-Core Construction Self-Supporting Hybrid Cable


(12 Fiber Version with Messenger Shown)
Galvanized Steel Messenger LDPE Jacket BrightWire Aluminum Braid Anti-Corrosion Tape BrightWire Aluminum Braid Anti-Corrosion Tape 0.0403 CU/Steel Dielectric 4.0mm Buffer Tube Strength Elements Gel Ripcord (1) 250 Micron Fibers

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

57 lbf/in (10 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-110-717-2002

Specifications are subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F52

Hybrid Single Jacket Outdoor Cable


Armored

Fiber Optic Cable Products

Features & Benefits


Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging and for communications Used for powering optoelectrical equipment down the line Provides line fault detection and location
Product Type/ Fiber Count/Pair Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term lbs/ kft Weight kg/ km

2 - 48 Fibers 1 Pair

O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP

0.50/12.7

7.5/19.0

5.0/12.7

607/2700

180/800

95

141

50 - 60 Fibers 1 Pair 62 - 84 Fibers 1 Pair 86 - 108 Fibers 1 Pair 110 - 132 Fibers 1 Pair 134 - 204 Fibers 1 Pair 206 - 276 Fibers 1 Pair

O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LA-HY-FZZNS/ XYXXX/1X22UTP

6 8 10 12 18 24

0.54/13.7 0.62/15.7

8.1/20.5 9.3/23.6

5.4/13.7 6.2/15.7 7.0/17.8 7.8/19.9 7.8/19.9 9.0/22.9

607/2700 607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800 180/800

110 141 174 214 199 258

164 210 259 318 296 383

0.70/17.8 10.5/26.7 0.78/19.9 11.7/29.8 0.78/19.9 11.7/29.8 0.90/22.9 13.5/34.3

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey

Hybrid Single Jacket Armored Cable


(108 Fiber Version Shown)
PE Outer Jacket Binder 22 AWG UTP (1) Water Swellable Tape Steel Tape Armoring Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord (2)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F53

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Hybrid Single Jacket Outdoor Cable


All-Dielectric

Fiber Optic Cable Products

Features & Benefits

Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for communications and tone locating when digging Used for powering optoelectrical equipment down the line Provides line fault detection and location
Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile lbs/meters Short Term Long Term Load Weight lbs/ kg/ kft km

Product Type/ Fiber Count/Pair Count

2 - 48 Fibers 1 Pair

O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP

0.44/11.3

6.7/16.9

4.4/11.3

607/2700

180/800

58

87

50 - 60 Fibers 1 Pair 62 - 84 Fibers 1 Pair 86 - 108 Fibers 1 Pair 110 - 132 Fibers 1 Pair 134 - 204 Fibers 1 Pair 206 - 276 Fibers 1 Pair

O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP O-XXX-LN-HY-FZZNS/ XYXXX/1X22UTP

6 8 10 12 18 24

0.48/12.3 0.56/14.3 0.65/16.4 0.73/18.5 0.73/18.5 0.85/21.5

7.3/18.4 8.5/21.5 9.7/24.6 10.9/27.8 10.9/27.8 12.7/32.2

4.8/12.3 5.6/14.3 6.5/16.4 7.3/18.5 7.3/18.5 8.5/21.5

607/2700 607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800 180/800

71 96 123 155 140 191

106 143 184 231 209 284

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Copper Twisted Pairs are identified with standard color coding: 1/White/Blue, 2/White/Orange, 3/White/Green, 4/White/Brown, 5/White/Grey

Hybrid Single Jacket All-Dielectric Cable


(108 Fiber Version Shown)
PE Outer Jacket Binder 22 AWG UTP (1) Water Swellable Tape Strength Elements Dielectric Strength Member Central Member Upjacket 3.0mm Gel Filled Buffer Tubes 250 Micron Fibers Ripcord

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F54

Hybrid Single Jacket Outdoor Cable + Conductor


Armored

Fiber Optic Cable Products

Features & Benefits


Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection Designed for tone locating when digging Provides line fault detection and location
Product Type/ Fiber Count/Conductor Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term lbs/ kft Weight kg/ km

2 - 48 Fibers 1-4 Conductors

O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG

0.50/12.7

7.5/19.0

5.0/12.7

607/2700

180/800

113

168

50 - 60 Fibers 1-4 Conductors 62 - 84 Fibers 1-4 Conductors 86 - 108 Fibers 1-4 Conductors 110 - 132 Fibers 1-4 Conductors 134 - 204 Fibers 1-4 Conductors 206 - 276 Fibers 1-4 Conductors

O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LA-HY-FZZNS/ XYXXX/NX12AWG

6 8 10 12 18 24

0.54/13.7 0.62/15.7

8.1/20.5 9.3/23.6

5.4/13.7 6.2/15.7 7.0/17.8 7.8/19.9 7.8/19.9 9.0/22.9

607/2700 607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800 180/800

128 160 193 232 217 276

191 238 287 346 323 411

0.70/17.8 10.5/26.7 0.78/19.9 11.7/29.8 0.78/19.9 11.7/29.8 0.90/22.9 13.5/34.3

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Copper Conductors Color Coding: Specified by customer

Hybrid Single Jacket All-Dielectric Cable


(108 Fiber Version Shown)
PE Outer Jacket Steel Tape Armoring Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) Binder 250 Micron Fibers Ripcord (1)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

250 lbf/in (44 N/mm) 35 Cycles Cable Diameter Dependant See long & short term tensile loads 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-33; IEC 60794-1-2; Sec. 5 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

28 F (-2 C)

FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F55

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Hybrid Single Jacket Outdoor Cable + Conductor


All-Dielectric

Fiber Optic Cable Products

Features & Benefits


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location
Product Type/ Fiber Count/Conductor Count Catalog Number Sub Units Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load lbs/meters Short Term Long Term lbs/ kft Weight kg/ km

2 - 48 Fibers 1-4 Conductors

O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG

0.44/11.3

6.7/16.9

4.4/11.3

607/2700

180/800

76

114

50 - 60 Fibers 1-4 Conductors 62 - 84 Fibers 1-4 Conductors 86 - 108 Fibers 1-4 Conductors 110 - 132 Fibers 1-4 Conductors 134 - 204 Fibers 1-4 Conductors 206 - 276 Fibers 1-4 Conductors

O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG O-XXX-LN-HY-FZZNS/ XYXXX/NX12AWG

6 8 10 12 18 24

0.48/12.3 0.56/14.3 0.65/16.4

7.3/18.4 8.5/21.5 9.7/24.6

4.8/12.3 5.6/14.3 6.5/16.4 7.3/18.5 7.3/18.5 8.5/21.5

607/2700 607/2700 607/2700 607/2700 607/2700 607/2700

180/800 180/800 180/800 180/800 180/800 180/800

89 114 142 174 159 210

133 170 211 259 236 312

0.73/18.5 10.9/27.8 0.73/18.5 10.9/27.8 0.85/21.5 12.7/32.2

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Copper Conductors are identified with a standard color coding: 1/Red, 2/Black, 3/Green, 4/Brown

Hybrid Single Jacket All-Dielectric Cable


(108 Fiber Version Shown)
PE Outer Jacket Water Swellable Tape Strength Elements 3.0mm Gel Filled Buffer Tubes Dielectric Strength Member 12 AWG Copper Conductor White (1) Binder 250 Micron Fibers Ripcord (1)

Environmental Specifications
Installation Temperature Operating Temperature Storage Temperature
Test

-22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle
Specifications are subject to change without notice.

28 F (-2 C)

FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F56

Single Jacket Single Armor Outdoor Cable + Conductor


Armored and Non-Armored, All Dielectric

Fiber Optic Cable Products

Features & Benefits


Arid-Core water blocking technology helps protect fibers from moisture and reduces termination effort Designed for tone locating when digging Provides line fault detection and location
Product Type/ Fiber Count Catalog Number Subunits Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short Term Long Term lbs/newtons lbs/newtons Weight lbs/ kg/ kft km

Armored 278-408 Fibers 1-4 Conductors

O-XXX-LA-HY-F24NS/ XYXXX/NX12AWG

18

0.90/22.9

13.5/34.3

9.0/22.9

607/2700

180/800

261

389

410-552 Fibers 1-4 Conductors All-Dielectric 278-408 Fibers 1-4 Conductors

O-XXX-LA-HY-F24NS/ XYXXX/NX12AWG O-XXX-LN-HY-F24NS/ XYXXX/NX12AWG

24

1.03/26.2

15.4/39.2

10.3/26.2 607/2700

180/800

337

502

18

0.84/21.5

12.7/32.2

8.5/21.5

607/2700

180/800

194

289

410-552 Fibers 1-4 Conductors

O-XXX-LN-HY-F24NS/ XYXXX/NX12AWG

24

0.97/24.8

14.6/39.2

9.8/24.8

607/2700

180/800

261

388

*Weights were calculated using a single 12 AWG conductor. Providing number of conductors, custom tables are available upon request.

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Buffer Tubes 13-23 repeat color sequence with tracer stripe Copper Conductors Color Coding: Specified by customer

Environmental Specifications
Installation Temperature Operating Temperature -22 to +158F (-30 to +70C) -40 to +158F (-40 to +70C) -40 to +167F (-40 to +75C)
Requirement Test Method

Single Jacket Single Armor Outdoor Cable + Conductor


(552 Fiber Armored,1 x 12 AWG Version Shown)
12 AWG Copper Conductor (1) PE Outer Jacket Steel Tape Armor Strength Elements Binder Water Swellable Tape 3.5mm Gel Filled Buffer Tubes 250 Micron Fibers Dielectric Strength Member Ripcord (1)

Storage Temperature
Test

Mechanical Test Specifications


Compression Flex Impact Strain Twist Water Penetration
Test

125 lbf/in (22 N/mm) 35 Cycles Cable Diameter Dependant 10 Cycles 24 Hours
Requirement

FOTP-41; IEC 60794-1-2; Sec. 7 FOTP-24; IEC 60794-1-2; Sec.10 FOTP-25; IEC 60794-1-2; Sec. 8 FOTP-85; IEC 60794-1-2; Sec. 11 FOTP-82; IEC 60794-1-2; Sec. 24
Test Method

See long & short term tensile loads FOTP-33; IEC 60794-1-2; Sec. 5

Environmental Test Specifications


Cable Freeze Drip Heat Age Low High Bend Temperature Cycle 28 F (-2 C) FOTP-98

140F (+70 C) FOTP-81; IEC 60794-1-2; Sec. 17 -40 to +185F (-40 to +85C) N/A -22 to +140F (-30 to +60C) FOTP-28; IEC 60794-1-2; Sec. 28 -40 to +158F (-40 to +70C) 24 Hours

Specifications are subject to change without notice.

CommScope Optical Cables are qualified under the general guidelines to the following specifications: ANSI/ICEA S-87-640-2006; Telcordia GR-20-CORE Issue 3; EN 187105

F57

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Indoor/Outdoor LSZH Distribution Cable


Low-Smoke Zero-Halogen, Riser-Rated

Fiber Optic Cable Products

LSZH Construction Permits Riser Applications as Well

Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen (LSZH) gives added protection to building occupants and equipment Tight buffered construction reduces installation cost
Catalog Number Outer Diameter Minimum Bend Radius Loaded Unloaded Maximum Tensile Load Short term Long term Weight lbs/kft kg/km

Fiber Count

2 Fibers (no central member) Z-2-DS-XY-FSUBK 4 Fibers (no central member) Z-4-DS-XY-FSUBK 6 Fibers 8 Fibers 12 Fibers Z-6-DS-XY-FSUBK Z-8-DS-XY-FSUBK Z-12-DS-XY-FSUBK Z-18-DS-XY-FSUBK Z-24-DS-XY-FSUBK Z-36-DS-XY-FMUBK Z-48-DS-XY-FMUBK Z-60-DS-XY-FMUBK Z-72-DS-XY-FMUBK

0.15/3.8 0.20/5.1 0.22/5.5 0.25/6.3 0.28/7.2 0.31/7.9 0.34/8.7 0.70/17.8 0.80/20.2 0.87/22.0 0.95/24.1

3.0/7.7 4.0/10.1 4.4/11.1 5.0/12.6 5.6/14.2 6.2/15.7 6.8/17.4 14.0/35.6 16.0/40.6 17.4/44.2 19.0/48.2

1.5/3.8 2.0/5.1 2.2/5.5 2.5/6.3 2.8/7.1 3.1/7.9 3.4/8.7 7.0/17.8 8.0/20.3 8.7/22.1 9.5/24.1

225/1001 300/1335 300/1335 300/1335 400/1780 300/1335 300/1335 800/3560 800/3560 1000/4450 1000/4450

68/300 90/400 90/400 90/400 120/534 90/400 90/400 240/1068 240/1068 300/1335 300/1335

7.8 13.5 17.6 23.7 32.6 37.0 45.2 162.4 206.6 260.7 320.5

11.6 20.1 26.3 35.3 48.6 55.0 67.3 241.6 307.4 387.9 477.0

18 Fibers 24 Fibers 36 Fibers 48 Fibers 60 Fibers 72 Fibers

Singlemode/Multimode Z--DS-CM-FSUBK/AAaaa/BBbbb Custom design - sizes/specs will vary depending on fiber count Composite (4 - 72 Fibers) Z--DS-CM-FMUBK/AAaaa/BBbbb Variables in the Catalog Number:
XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type

bbb is replaced by multimode fiber count BB is replaced by multimode type

Tight Buffer Tubes/Fiber identification colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Jacket Color: UV Stabilized Black

LSZH Indoor/Outdoor Riser-Rated Distribution Cable (Multi-Unit) (72 Fiber Version Shown)
Low-Smoke Zero-Halogen (LSZH) Outer Jacket Triathlon Subunit with Arid-Core

12 Fiber Unit (Single Unit)

LSZH Jacket Aramid Yarn Central Strength Member 900 Micron Tight-Buffered 250 Micron Fiber Ripcord Water Blocking Thread

Central Strength Member Water Blocking Tapes Ripcord

Mechanical Properties
Description Specification Test Method

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-40 to 158F (-40 to 70C) -22 to 158F (-30 to 70C) -40 to 167F (-40 to 75C) Exceeds 126 lbf/in (22 N/mm) Exceeds 4.34 lbft (5.88 Nm) Exceeds 100 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

Specifications are subject to change without notice.

CommScope Fiber Optic Premises cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F58

Indoor/Outdoor LSZH Cordage Cable


Low-Smoke Zero-Halogen, Riser-Rated

Fiber Optic Cable Products

LSZH Construction Permits Riser Applications as Well


Black jackets are UV-stable for outdoor use yet meet critical NEC/CEC riser (OFNR and OFN-LS) safety standards Riser rating eliminates splice points at the building entrance Arid-Core water blocking technology helps protect fibers from moisture Low-Smoke Zero-Halogen gives added protection to building occupants and equipment Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination
Catalog Number Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short term Long term lbs./ Newtons lbs./Newtons lbs/ kft Weight kg/ km

Cable Type/Unit Size

Simplex/1.6mm Simplex/2.5mm Simplex/2.9mm Zipcord/1.6mm

Z-1-SP-XY-F16BK Z-1-SP-XY-F25BK Z-1-SP-XY-F29BK Z-2-ZC-XY-F16BK

0.067/1.70 0.098/2.50 0.114/2.90 0.067 x 0.138/ 1.70 x 3.50 0.098 x 0.201/ 2.50 x 5.10 0.114 x 0.232/ 2.90 x 5.90 0.114/2.90

2.0/5.0 2.0/5.0 2.3/5.8 2.0/5.0

1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0

35/156 60/267 60/267 70/311

11/47 18/80 18/80 21/93

1.9 4.5 6.2 3.8

2.9 6.7 9.2 5.6

Zipcord/2.5mm Zipcord/2.9mm Interconnect/2.9mm

Z-2-ZC-XY-F25BK Z-2-ZC-XY-F29BK Z-2-IC-XY-F29BK

2.0/5.0 2.3/5.8 2.3/5.8

1.2/3.0 1.2/3.0 1.2/3.0

90/400 90/400 70/311

27/120 27/120 21/93

9.0 12.4 5.0

13.4 18.5 7.4

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

For Composites Only:

aaa is replaced with singlemode fiber count AA is replaced with singlemode type Tight Buffer/Fiber Identification Colors: 1/Blue, 2/Orange Jacket Color: UV Stabilized Black

bbb is replaced by multimode fiber count BB is replaced by multimode type

Indoor/Outdoor LSZH Simplex Cable


LSZH Riser Rated Outer Jacket Water Blocking System Aramid Yarn 900m Tight Buffer 250m Optical Fiber

Indoor/Outdoor LSZH Zipcord Cable


LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900m Tight Buffer 250m Optical Fiber

Indoor/Outdoor LSZH 2-Fiber Interconnect Cable


LSZH Riser Rated Outer Jacket Aramid Yarn Water Blocking System 900m Tight Buffer 250m Optical Fibers

Mechanical Properties
Description Specification Test Method

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-40 to 158F (-40 to 70C) -22 to 158F (-30 to 70C) -40 to 167F (-40 to 75C) Exceeds 57 lbf/in (10 N/mm) Exceeds 0.54 lbfft (0.74 Nm) Exceeds 300 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

Specifications are subject to change without notice.

CommScope Fiber Optic Premise cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Water penetration performance meets the requirements of Telcordia GR-20-CORE, Issue 2.

F59

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Premise Riser-Rated Distribution Cable


Fiber Optic Cable Products
For Indoor Applications that Require a Riser Rating
Meets critical NEC/CEC riser (OFNR) safety standards Colored-Coded and color-coded fibers help ease installation
Fiber Count Catalog Number Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short term Long term lbs./ Newtons lbs./Newtons lbs/ kft Weight kg/ km

2 Fibers 4 Fibers 6 Fibers 8 Fibers 12 Fibers

R-2-DS-XY-FSUZZ R-4-DS-XY-FSUZZ R-6-DS-XY-FSUZZ R-8-DS-XY-FSUZZ R-12-DS-XY-FSUZZ R-18-DS-XY-FSUZZ R-24-DS-XY-FSUZZ

0.16/4.1 0.19/4.8 0.20/5.1 0.22/5.5 0.24/6.0 0.30/7.7 0.33/8.4

3.2/8.1 3.8/9.5 4.1/10.3 4.3/11.0 4.7/12.1 6.0/15.4 6.6/16.7

1.6/4.1 1.9/4.8 2.0/5.1 2.2/5.5 2.4/6.0 3.0/7.7 3.3/8.4 5.8/14.6 6.3/16.1 7.1/18.0 7.9/20.0 9.3/23.7 10.3/26.1

225/1001 300/1335 300/1335 300/1335 300/1335 300/1335 300/1335 800/3560 800/3560 1000/4450 1000/4450 1000/4450 1000/4450

68/300 90/400 90/400 90/400 90/400 90/400 90/400 240/1068 240/1068 300/1335 300/1335 300/1335 300/1335

8.6 13.1 15.2 17.2 21.7 32.1 37.9 112.0 143.0 188.0 232.0 337.0 350.0

12.9 19.4 22.7 25.7 32.2 47.7 56.4 167.0 212.0 279.0 345.0 502.0 522.0

18 Fibers 24 Fibers 36 Fibers (3 subunits) 48 Fibers (4 subunits) 60 Fibers (5 subunits) 72 Fibers (6 subunits) 96 Fibers (8 subunits) 144 Fibers (12 subunits) Singlemode/Multimode Composite (4 - 144 Fibers)

R-36-DS-XY-FMUZZ 0.58/14.6 11.5/29.3 R-48-DS-XY-FMUZZ 0.63/16.1 12.7/32.2 R-6-DS-XY-FMUZZ 0.71/18.0 14.2/36.1 R-72-DS-XY-FMUZZ 0.79/20.0 15.8/40.1 R-96-DS-XY-FMUZZ 0.93/23.7 18.7/47.5 R-144-DS-XY-FMUZZ 1.03/26.1 20.5/52.2

R-XXX-DS-CM-FSUOR/AAaaa/BBbbb R-XXX-DS-CM-FMUOR/AAaaa/BBbbb

Custom design - sizes/specs will vary depending on fiber count

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber


TM

For Composites Only:

aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded in the same manner.

Riser Distribution Cable (Multi-Unit)


(72 and 12 Fiber Versions Shown)
Riser Rated Outer Jacket Core Wrap Tape Central Strength Member 12 Fiber Subunit

12 Fiber Unit (Single Unit)


Riser Rated Outer Jacket Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber Ripcord

Mechanical Properties
Description Specification Test Method

Ripcord

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-4 to 158F (-20 to 70C) -4 to 158F (-20 to 70C) -40 to 158F (-40 to 70C) Exceeds 57 lbf/in (10N/mm) Exceeds 4.34 lbft (5.88 Nm) Exceeds 100 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

Specifications are subject to change without notice.

CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F60

Premise Riser-Rated Cordage Cable


Fiber Optic Cable Products

Several Constructions Available for a Variety of Applications


For Indoor Applications that Require a Riser Rating
Meets critical NEC/CEC riser (OFNR) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination
Cable Type/Unit Size Catalog Number Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short term Long term lbs./ Newtons lbs./Newtons lbs/ kft Weight kg/ km

Simplex/1.6mm Simplex/2.0mm Simplex/2.5mm Simplex/2.9mm Zipcord/1.6mm

R-1-SP-XY-F16ZZ R-1-SP-XY-F20ZZ R-1-SP-XY-F25ZZ R-1-SP-XY-F29ZZ R-2-ZC-XY-F16ZZ

0.067/1.70 0.079/2.00 0.098/2.50 0.114/2.90 0.067 x 0.138/ 1.70 x 3.50 0.079 x 0.161/ 2.00 x 4.10 0.098 x 0.201/ 2.50 x 5.10 0.114 x 0.232/ 2.90 x 5.90 0.114/2.90

2.0/5.0 2.0/5.0 2.0/5.0 2.3/5.8 2.0/5.0

1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0

35/156 50/222 60/267 60/267 70/311

11/47 15/67 18/80 18/80 21/93

1.8 2.8 4.2 5.8 3.7

2.7 4.1 6.3 8.7 5.5

Zipcord/2.0mm Zipcord/2.5mm Zipcord/2.9mm Interconnect /2.9mm

R-2-ZC-XY-F20ZZ R-2-ZC-XY-F25ZZ R-2-ZC-XY-F29ZZ R-2-IC-XY-F29ZZ

2.0/5.0 2.0/5.0 2.3/5.8 2.3/5.8

1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0

80/356 90/400 90/400 70/311

24/107 27/120 27/120 21/93

5.4 8.5 11.7 4.7

8.0 12.6 17.4 7.0

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber 8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber
TM

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

ZZ

= Standard Jacket Color

YL (Yellow - Singlemode Cable)

Fiber Identification Colors: 1/Blue, 2/Orange

OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable)

Riser Simplex Cable


Riser Rated Outer Jacket 900 m Tight Buffer 250 m Optical Fiber Aramid Yarn

Riser Zipcord Cable


Riser Rated Outer Jacket

Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber

Riser 2-Fiber Interconnect Cable


Riser Rated Outer Jacket Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber

Mechanical Properties
Description Specification Test Method

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-4 to 158F (-20 to 70C) -4 to 158F (-20 to 70C) -40 to 158F (-40 to 70C) Exceeds 57 lbf/in (10N/mm) Exceeds 0.54 lbft (0.74 Nm) Exceeds 300 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Specifications are subject to change without notice.

F61

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Premise Plenum-Rated Distribution Cable


Fiber Optic Cable Products
For Indoor Applications that Require a Plenum Rating
Meets critical NEC/CEC plenum (OFNP) safety standards Color-coded subunits and color-coded fibers help ease installation
Fiber Count Catalog Number Outer Diameter inch/mm Minimum Bend Radius Loaded Unloaded inch/cm inch/cm Maximum Tensile Load Short term Long term lbs./ Newtons lbs./Newtons lbs/ kft Weight kg/ km

2 Fibers 4 Fibers 6 Fibers 8 Fibers 12 Fibers

P-2-DS-XY-FSUZZ P-4-DS-XY-FSUZZ P-6-DS-XY-FSUZZ P-8-DS-XY-FSUZZ P-12-DS-XY-FSUZZ P-18-DS-XY-FSUZZ P-24-DS-XY-FSUZZ P-36-DS-XY-FMUZZ P-48-DS-XY-FMUZZ

0.15/3.9 0.17/4.4 0.19/4.8 0.20/5.1 0.23/5.8 0.31/7.9 0.33/8.5

3.1/7.8 3.4/8.7 3.8/9.7 4.0/10.2 4.6/11.7 6.2/15.8 6.7/16.9

1.5/3.9 1.7/4.4 1.9/4.8 2.0/5.1 2.3/5.8 3.1/7.9 3.3/8.5 5.4/13.7 5.9/15.1 6.8/17.2 7.5/19.1 9.1/23.1 9.7/24.8

225/1001 300/1335 300/1335 300/1335 300/1335 300/1335 300/1335 800/3560 800/3560 1000/4450 1000/4450 1000/4450 1000/4450

68/300 90/400 90/400 90/400 90/400 90/400 90/400 240/1068 240/1068 300/1335 300/1335 300/1335 300/1335

8.8 12.2 15.1 16.8 20.8 40.9 47.3 128.0 138.0 190.0 237.0 361.0 357.0

13.1 18.2 22.5 24.9 30.9 60.9 70.4 191.0 205.0 282.0 353.0 537.0 531.0

18 Fibers 24 Fibers 36 Fibers (3 subunits) 48 Fibers (4 subunits) 60 Fibers (5 subunits) 72 Fibers (6 subunits) 96 Fibers (8 subunits) 144 Fibers (12 subunits) Singlemode/Multimode Composite (4 - 144 Fibers)

0.54/13.7 10.8/27.4 0.59/15.1 11.9/30.2

P-6-DS-XY-FMUZZ 0.68/17.2 13.6/34.4 P-72-DS-XY-FMUZZ P-96-DS-XY-FMUZZ P-144-DS-XY-FMUZZ 0.75/19.1 15.1/38.2 0.91/23.1 18.2/46.1 0.97/24.8 19.5/49.5

P-XXX-DS-CM-FSUOR/AAaaa/BBbbb P-XXX-DS-CM-FMUOR/AAaaa/BBbbb

Custom design - sizes/specs will vary depending on fiber count

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber


TM

For Composites Only:

aaa is replaced with singlemode fiber count bbb is replaced by multimode fiber count AA is replaced with singlemode type BB is replaced by multimode type Tight Buffer/Fiber Colors: 1/Blue, 2/Orange, 3/Green, 4/Brown, 5/Slate, 6/White, 7/Red, 8/Black, 9/Yellow, 10/Violet, 11/Rose, 12/Aqua Subunits are color-coded for easy identification

Plenum Distribution Cable (Multi-Unit)


(72 and 12 Fiber Versions Shown)
Plenum Rated Outer Jacket

12 Fiber Unit (Single Unit)


Riser Rated Outer Jacket Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber Ripcord

Central Strength Member

Mechanical Properties
12 Fiber Subunit Description Specification Test Method

Ripcord

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-4 to 158F (-20 to 70C) 32 to 158F (0 to 70C) -40 to 158F (-40 to 70C) Exceeds 57 lbf/in (10N/mm) Exceeds 4.34 lbft (5.88 Nm) Exceeds 100 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

Specifications are subject to change without notice.

CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F62

Premise Plenum-Rated Cordage Cable


Several Constructions Available for a Variety of Uses

Fiber Optic Cable Products

For Indoor Applications that Require a Plenum Rating


Meets critical NEC/CEC plenum (OFNP) safety standards Simplex and zipcord cables are available in a variety of sizes Designed for ease of handling and termination
Cable Type/Unit Size Catalog Number

Outer Diameter inch/mm

Minimum Bend Radius Loaded Unloaded inch/cm inch/cm

Maximum Tensile Load Short term Long term lbs./ Newtons lbs./Newtons

Weight lbs/ kg/ kft km

Simplex/1.6mm Simplex/2.0mm Simplex/2.5mm Simplex/2.9mm Zipcord/1.6mm

P-1-SP-XY-F16ZZ P-1-SP-XY-F20ZZ P-1-SP-XY-F25ZZ P-1-SP-XY-F29ZZ

0.067/1.70 0.079/2.00 0.098/2.50 0.114/2.90

2.0/5.0 2.0/5.0 2.0/5.0 2.3/5.8 2.0/5.0

1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0

35/156 50/222 60/267 60/267 70/311

11/47 15/67 18/80 18/80 21/93

2.0 3.0 4.9 6.8 4.0

3.0 4.5 7.3 10.1 6.0

P-2-ZC-XY-F16ZZ 0.067 x 0.138/ 1.70 x 3.50 P-2-ZC-XY-F20ZZ 0.079 x 0.161/ 2.00 x 4.10 P-2-ZC-XY-F25ZZ 0.098 x 0.201/ 2.50 x 5.10 P-2-ZC-XY-F29ZZ 0.114 x 0.232/ 2.90 x 5.90 P-2-IC-XY-F29ZZ 0.114/2.90

Zipcord/2.0mm Zipcord/2.5mm Zipcord/2.9mm Interconnect/2.9mm

2.0/5.0 2.0/5.0 2.3/5.8 2.3/5.8

1.2/3.0 1.2/3.0 1.2/3.0 1.2/3.0

80/356 90/400 90/400 70/311

24/107 27/120 27/120 21/93

5.9 9.8 13.6 5.8

8.8 14.6 20.2 8.6

Variables in the Catalog Number:


XXX = Total Fiber Count XY = Fiber Grade 8W LightScope ZWP Dispersion-Unshifted, Matched-Clad Singlemode Fiber

6F 62.5m, FDDI Grade Multimode Fiber 5M LazrSPEED 150, 50m, Multimode Fiber

8T LightScope NZD Non-Zero DispersionShifted Singlemode Fiber


TM

ZZ

= Standard Jacket Color

YL (Yellow - Singlemode Cable)

Fiber Identification Colors: 1/Blue, 2/Orange

OR (Orange - Multimode or Composite Cable) AQ (Aqua - LaserCore Cable)

Plenum Simplex Cable


Plenum Rated Outer Jacket 900 m Tight Buffer 250 m Optical Fiber Aramid Yarn

Plenum Zipcord Cable


Plenum Rated Outer Jacket

Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber

Plenum 2-Fiber Interconnect Cable


Plenum Rated Outer Jacket Aramid Yarn 900 m Tight Buffer 250 m Optical Fiber

Mechanical Properties
Description Specification Test Method

Operating Temperature Installation Temperature Storage Temperature Crush Resistance Impact Resistance Flexing Twist Bend

-4 to 158F (-20 to 70C) 32 to 158F (0 to 70C) -40 to 158F (-40 to 70C) Exceeds 57 lbf/in (10N/mm) Exceeds 0.54 lbft (0.74 Nm) Exceeds 300 cycles Exceeds

FOTP-3 N/A N/A FOTP-41 FOTP-25 FOTP-104 FOTP-85

CommScope Fiber Optic Premises Cables are qualified to the requirements of Telcordia GR-409-CORE, Issue 1. Specifications are subject to change without notice.

F63

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable

Packaging and Shipping Information

Fiber Optic Cable Products

Packaging and Shipping Fiber optic cable is packaged for shipment on wooden or composite reels. Each package contains only one continuous length of cable. The packaging is designed to prevent damage to the cable during shipping and handling. Fiber cable reels are protected with a reel wrap, the highest technology available today. This wrap is stronger, lighter and more environmentally friendly than other methods of lagging. In addition, reel wrap is simple to remove from the reel and readily disposable. All reel sizes between 35 and 78 inches will be blocked and palletized to help ensure safe arrival to the customer. Reels larger than 78 inches are placed on the rolling edge and securely fastened to the trailer during shipment. Each reel is plainly marked to indicate the direction in which it should be rolled to prevent loosening of the cable on the reel.

Traverse Width

Flange Diameter

Drum Diameter

Method of Shipment CommScopes customary method of shipment of fiber optic cable from Claremont, North Carolina to the purchasers site will vary depending on factors such as the size and number of cable reels, and the destination location. Shipper options include Federal Express, UPS, BAX, LTL motor freight carriers and CommScopes own fleet of trucks, Cable Transport. Some trucks within CommScopes fleet are equipped with Cargo Master equipment for ease in unloading cable reels on location where no loading dock is available. CommScope has red arm Cargo Masters, which can lift anything 2,500 pounds or less. CommScope also has white arm Cargo Masters which will lift anything up to 8,000 pounds that is on an 84 reel or smaller. These specially equipped trucks are available by request.

International Packaging Products shipped outside the continental United States are protected with reel wrap, lagged with wood, and blocked and palletized (for reel sizes between 35 and 78 inches) or placed on the rolling edge and securely fastened to international shipping containers.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F64

Fiber Optic Cable


Fiber Optic Cable Products

Packaging and Shipping Information


Outside Plant Dry Stranded Loose Tube Armored (D-LA) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1,125
2Flange Clearance

3,805 6,706 8,816 15,058 16,987 22,681 29,384 38,603 47,398 59,951 N/A N/A

3,752 6,008 8,021 13,828 15,888 20,988 26,363 34,883 44,759 56,558 59,942 N/A

2,834 4,988 6,249 10,597 12,526 16,528 20,713 27,084 34,523 43,978 50,344 59,910

2,414 3,838 5,231 8,624 9,881 12,973 16,715 21,831 27,371 35,569 39,867 56,045

1,742 3,101 3,885 6,868 7,914 10,548 12,885 17,174 22,174 27,634 31,433 42,748

1,722 3,101 3,885 6,868 7,914 10,548 12,885 17,174 22,114 27,634 31,433 42,748

1,411 2,510 3,165 5,279 5,821 7,724 9,987 13,002 16,407 20,574 23,844 33,491

Outside Plant Dry Stranded Loose Tube Non-Armored (D-LN) Cables


Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

5,195 8,572 11,173 19,027 21,977 29,256 36,834 48,165 59,950 N/A N/A N/A

4,783 7,784 10,816 17,654 20,432 27,346 34,662 45,550 56,756 59,942 N/A N/A

3,671 6,029 7,922 12,932 15,705 20,773 26,098 34,589 42,952 54,434 59,910 N/A

2,847 4,566 6,156 10,648 11,680 15,736 20,458 26,798 34,179 42,065 48,310 59,872

2,054 3,683 4,614 7,832 8,819 11,903 15,199 20,008 25,296 33,135 37,275 46,351

2,054 3,683 4,614 7,832 8,819 11,903 15,199 20,008 25,296 33,135 37,275 46,351

1,704 2,630 3,755 6,035 7,157 9,388 11,848 15,583 19,307 23,925 27,448 33,491

Outside Plant Dry Loose Tube Double Jacket, Single Armor (D-L2) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

2,407 3,831 5,328 8,760 10,464 13,973 17,505 23,217 28,917 35,461 41,206 55,862

2,110 3,756 5,145 8,509 9,727 12,793 16,490 21,578 27,071 35,237 39,508 53,103

1,735 3,091 3,963 6,835 7,874 10,502 13,106 17,098 22,003 27,501 31,272 43,166

1,449 2,560 3,289 5,932 6,517 8,590 10,960 14,480 19,034 23,625 27,115 36,645

1,191 2,083 2,684 4,651 5,595 7,459 9,034 11,843 15,108 19,069 22,231 29,694

1,191 2,083 2,684 4,651 5,595 7,459 9,034 11,843 15,108 19,069 22,231 29,694

N/A 1,651 2,204 3,913 4,319 5,864 7,270 9,442 11,597 15,869 17,770 23,862

Reel Weights subject to change without notice.

F65

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable

Packaging and Shipping Information

Fiber Optic Cable Products

Outside Plant Stranded Loose Tube Armored (O-LA/25T) Cables


Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

3 35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

4,118 6,832 8,950 15,045 16,972 22,663 29,357 38,572 48,885 59,951 N/A N/A

3,746 6,121 8,615 14,008 15,856 21,265 27,785 36,172 44,670 57,121 59,942 N/a

2,831 5,097 6,778 10,761 12,506 16,786 21,621 28,238 34,470 44,507 50,944 59,910

2,411 3,836 5,227 8,615 9,869 12,960 16,697 21,809 28,502 35,530 41,293 55,980

1,741 3,099 3,882 6,861 7,906 10,539 12,872 17,158 22,092 27,607 31,401 43,342

1,741 3,099 3,882 6,861 7,906 10,539 12,872 17,158 22,092 27,607 31,401 43,342

1,410 2,509 3,163 5,276 5,817 7,719 9,980 12,994 16,396 20,560 23,827 33,491

Outside Plant Stranded Loose Tube Non-Armored (O-LN/25T) Cables


Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

5,189 8,565 11,162 19,002 21,947 29,221 36,785 48,108 59,952 N/A N/A N/A

4,773 7,772 10,797 17,847 20,693 27,651 34,583 45,458 56,628 59,942 N/A N/A

3,666 6,023 7,911 13,878 15,677 21.056 26,054 34,537 42,879 54,346 59,910 N/A

2,8473 4,562 6,149 10,633 12.329 16,579 20,428 26,762 34,127 44,128 48,896 59,873

2,052 3,681 4,611 7,825 9,001 11,895 15,186 19,992 25,274 33,108 37,242 46,351

2,052 3,681 4,611 7,825 9,011 11,895 15,186 19,992 25,274 33,108 37,242 46,351

1,703 2,629 3,752 6,031 7,152 9,382 11,849 15,573 19,292 23,908 27,427 33,491

Outside Plant Loose Tube Double Jacket, Single Armor (O-L2/25T) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6@1 218-288F 15@9@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

2,407 3,831 5,328 8,760 10,464 13,973 17,505 23,217 28,917 35,461 41,206 55,862

2,110 3,756 5,145 8,509 9,727 12,793 16,490 21,578 27,071 35,237 39,508 53,103

1,735 3,091 3,963 6,835 7,874 10,502 13,106 17,098 22,003 27,501 31,272 43,166

1,449 2,560 3,289 5,932 6,517 8,590 10,960 14,480 19,034 23,625 27,115 36,645

1,191 2,083 2,684 4,651 5,595 7,459 9,034 11,843 15,108 19,069 22,231 29,694

1,191 2,083 2,684 4,651 5,595 7,459 9,034 11,843 15,108 19,069 22,231 29,694

N/A 1,651 2,204 3,913 4,319 5,864 7,270 9,442 11,597 15,869 17,770 23,862

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F66

Fiber Optic Cable


Fiber Optic Cable Products

Packaging and Shipping Information


Outside Plant Stranded Loose Tube Armored (O-LA), Loose Tube Non-Armored (O-LN) and Loose Tube Double Jacket, Single Armored (O-L2) High Density Cables
Armored (O-LA) Flange x Drum x Traverse Reel Weight (lbs) 290-432F 12@6@1 434-576F 15@9@1 Non-Armored (O-LN) 290-432F 12@6@1 434-576F 15@9@1 Double Jacket, Single Armored (O-L2) 290-432F 12@6@1

35 x 16.5 x 18 42 x 24 x 25 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 32 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 176 370 433 506 627 758 913 958 1,020
2Flange Clearance

N/A 1,713 2,270 4,019 4,456 5,855 7,472 9,670 12,648 15,844 17,740 24,298

N/A 1,327 1,713 2,884 3,341 4,469 5,902 7,327 9,224 11,853 13,489 18,714

N/A 2,099 2,709 4,585 5,059 6,781 9,145 11,427 13,778 17,518 20,545 27,682

N/A 1,612 2,104 3,387 3,757 4,998 6,483 8,484 10,545 13,389 15,143 20,696

N/A 1,325 1,770 2,875 3,330 4,457 5,882 7,521 9,464 12,126 13,796 19,074

Outside Plant Stranded Loose Tube Armored (O-LA/20T) and Loose Tube Non-Armored (O-LN/20T) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-72 6@1 Armored (O-LA/20T) 74-96 98-120 8@1 10@1 122-144 12@1 2-72 6@1 Non-Armored (O-LN/20T) 74-96 98-120 8@1 10@1 122-144 12@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

4,698 7,678 10,032 16,664 19,397 26,033 32,770 43,244 54,160 59,962 N/A N/A

3,666 6,023 7,911 13,878 15,677 21,056 26,054 34,537 42,879 54,346 59,945 N/A

3,169 5,178 6,978 11,540 13,568 17,818 21,785 28,837 36,490 46,879 53,479 59,920

2,470 4,313 5,403 9,487 10,599 14,131 17,697 23,428 29,155 37,670 43,599 58,733

5,935 9,786 13,244 21,938 24,908 33,282 42,214 55,904 59,962 N/A N/A N/A

4,766 7,901 10,939 17,820 20,659 27,612 34,527 45,920 57,194 59,945 N/A N/A

3,731 6,609 8,725 14,151 16,834 22,501 27,656 36,497 46,540 59,333 59,920 N/A

2,901 5,076 6,871 11,578 12,668 16,975 21,859 28,503 36,083 46,421 52,968 59,885

Outside Plant Stranded Loose Tube Armored (Z-LA/20G) and Loose Tube Non-Armored (Z-LN/20G) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-72 6@1 Armored (Z-LA/20G) 74-96 98-120 8@1 10@1 122-144 12@1 2-72 6@1 Non-Armored (Z-LN/20G) 74-96 98-120 8@1 10@1 122-144 12@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

3,383 5,923 7,813 12,784 14,747 19,573 24,770 32,930 42,545 53,982 59,962 N/A

2,838 4,993 6,256 10,612 12,545 16,550 20,387 27,120 34,575 44,042 50,423 59,945

2,469 4,312 5,403 9,485 10,596 14,128 17,693 23,423 29,148 37,662 43,589 58,719

2,066 3,601 4,536 7,727 8,878 11,737 14,988 19,773 23,932 31,000 34,989 48,345

4,276 7,572 9,784 16,317 18,383 24,408 31,366 40,990 51,613 59,962 N/A N/A

3,753 6,010 8,023 13,832 15,893 20,994 26,371 34,892 44,772 56,574 59,945 N/A

2,901 5,076 6,871 11,578 12,668 16,975 21,859 28,503 36,083 46,421 52,968 59,920

2,471 4,315 5,406 9,493 10,606 14,140 17,709 23,443 29,175 37,696 43,631 58,775

F67

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable

Packaging and Shipping Information

Fiber Optic Cable Products

Outside Plant Figure-8 Armored (M-LA) and Non-Armored (M-LN) Cables


Flange x Drum x Traverse Reel Weight (lbs) 5@1 2-60 6@1 62-72 Armored (M LA) 12@1 12@6 74-144 146-216 15@9 218-288 5@1 2-60 6@1 62-72 Non-Armored (M LN) 12@1 12@6 74-144 146-216 15@9 218-288

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 32 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1,125

1,671 2,807 3,726 6,218 7,256 9,604 12,283 16,062 20,201 26,345 29,968 34,498

1,559 2,498 3,380 5,801 6,443 8,569 11,179 14,678 18,030 23,153 26,599 34,498

867 1,359 1,983 2,961 3,594 4,751 6,306 8,271 9,887 13,036 14,411 20,364

867 1,359 1,983 2,961 3,594 4,751 6,306 8,271 9,887 13,036 14,411 20,364

N/A 1,082 1,449 2,578 2,887 3,862 4,717 6,309 7,752 9,878 11,745 16,271

1,955 3,358 4,486 7,546 8,653 11,364 14,727 19,587 24,056 30,211 34,498 N/A

1,748 3,036 3,994 6,733 7,557 10,302 13,068 17,017 21,264 26,957 30,567 34,498

909 1,605 2,032 3,431 3,965 5,417 6,820 8,905 11,129 14,509 15,929 22,219

909 1,605 2,032 3,431 3,965 5,417 6,820 8,905 11,129 14,509 15,929 22,219

N/A 1,309 1,711 2,637 3,242 4,308 5,198 6,907 8,919 11,256 12,544 17,227

2 Flange Clearance

Outside Plant Figure-8 Armored (M-LA/25D) and Non-Armored (M-LN/25D) Cables


Armored (M LA/25D) Flange x Drum x Traverse Reel Weight (lbs) 5@1 2-60 1@1 2-60 5@1 2-60 5@1 2-60 Non-Armored (M LN/25D) 5@1 2-60 5@1 2-60

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 32 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1,125
2 Flange Clearance

2,266 3,719 5,363 8,645 9,935 13,124 17,245 22,352 27,601 34,498 N/A N/A

2,069 3,359 4,799 7,821 8,861 11,874 15,563 20,450 25,252 30,000 N/A N/A

1,970 3,239 4,516 7,410 8,324 11,249 14,722 19,023 23,490 30,215 34,063 34,498

2,773 4,633 6,411 10,421 12,342 16,146 20,543 26,934 33,549 34,498 N/A N/A

2,551 4,088 5,785 9,494 11,108 14,711 18,208 24,294 30,000 N/A N/A N/A

2,329 3,816 5,316 8,800 10,182 13,634 17,275 22,709 28,286 34,498 N/A N/A

Outside Plant ADSS Loose Tube (S-LN) Cables


Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1,125
2Flange Clearance

3,733 6,612 8,729 13,954 16,844 22,187 27,672 36,516 45,075 59,367 66,768 85,636

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F68

Fiber Optic Cable


Fiber Optic Cable Products

Packaging and Shipping Information


Indoor/Outdoor Stranded Loose Tube Non-Armored (R-LN/25D) Cables
Flange x Drum x Traverse Reel Weight (lbs) 2-60F 5@1 62-72F 6@1 74-96F 8@1 98-120F 10@1 122-144F 12@1 146-216F 12@6 218-288F 15@9

3 35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1125
2Flange Clearance

3,808 6,710 8,822 15,071 17,002 22,699 29,410 38,634 47,440 59,950 N/A N/A

3,748 6,123 8,619 14,016 15,865 21,275 27,380 36,191 44,695 57,152 59,942 N/A

2,831 5,097 6,778 10,761 12,506 16,786 21,621 28,238 34,470 44,507 50,944 59,910

2,411 3,836 5,227 8,615 9,869 12,960 16,697 21,809 28,502 35,530 41,293 55,980

1,741 3,099 3,882 6,860 7,904 10,537 12,870 17,155 22,088 27,602 31,394 43,333

1,691 3,035 3,825 6,125 7,280 9,533 12,025 15,780 20,519 25,786 29,456 40,371

1,361 2,145 3,103 4,737 5,715 7,600 9,834 12,830 15,336 20,362 22,510 31,361

Indoor/Outdoor Stranded Loose Tube Plenum Non-Armored (P-LN/25D) Cables and Plenum/Interlocking Armor (P-LZ/25D) Cables
Flange x Drum x Traverse Reel Weight (lbs) 5@1 2-60 Non-Armored (P-LN/25D) 6@1 8@1 10@1 62-72 74-144 146-216 12@1 218-288 5@1 2-60 Interlocking Armor (P-LZ/25D) 6@1 8@1 10@1 62-72 74-144 146-216 12@1 218-288

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 32 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40 96 x 44 x 46


All Units in Feet

70 109 118 140 350 433 580 627 758 850 958 1,125
2 Flange Clearance

5,466 9,523 12,224 20,610 23,795 31,486 40,683 53,412 59,950 N/A N/A N/A

5,297 8,699 11,860 19,205 22,219 29,539 37,957 50,160 59,942 N/A N/A N/a

3,821 6,728 8,850 14,120 16,794 22,455 28,009 36,895 47,033 59,199 59,910 N/A

2,901 5,076 6,871 11,578 12,668 16,975 21,859 28,503 36,083 46,421 52,968 59,872

2,343 3,753 5,249 8,662 9,714 13,023 16,468 21,553 27,035 35,191 39,453 46,351

N/A 2,701 3,832 6,140 7,118 9,555 10,000 N/A N/A N/A N/A N/A

N/A 2,701 3,832 6,140 7,118 9,555 10,000 N/A N/A N/A N/A N/A

N/A 2,080 N/A N/A 5,581 7,442 9,012 10,000 N/A N/A N/A N/A

N/A 2,034 N/A N/A 4,936 6,637 8,128 10,000 N/A N/A N/A N/A

N/A N/A N/A N/A N/A 5,130 6,448 8,444 10,000 N/A N/A N/A

Indoor/Outdoor and Outside Plant Central Tube Non-Armored (R-CN, O-CN) Cables
Flange x Drum x Traverse Reel Weight (lbs) RCN 1-24 CN 1-24 CN 26-48

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40


All Units in Feet 2 Flange Clearance

70 109 118 140 350 433 580 627 758 850

5,288 8,687 12,006 19,168 22,173 29,487 38,371 48,648 N/A N/A

5,288 8,687 12,006 19,168 22,173 29,487 38,371 48,648 N/A N/A

3,668 6,026 7,917 12,922 15,691 20,757 26,076 34,563 42,915 48,593

Reel Weights subject to change without notice.

F69

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable

Packaging and Shipping Information

Fiber Optic Cable Products

Outside Plant Central Tube Armored (O-CA) Cables


Flange x Drum x Traverse Reel Weight (lbs) CA 2-24 CA 26-48

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x 40 x 40


All Units in Feet 2 Flange Clearance

70 109 118 140 350 433 580 627 758 850 958

4,278 7,574 9,786 16,322 18,389 24,414 31,376 41,002 51,545 N/A N/A

3,254 5,169 6,964 11,700 13,532 18,068 23,067 30,430 38,278 46,761 51,545

Outside Plant Flat Drop (O-DF, O-DF/HY) Cables


Flange x Drum x Traverse Reel Weight (lbs) ODF 1-12 ODF/HY 1-12

LZSH Indoor/Outdoor (Z-DN) Cables


Flange x Drum x Traverse Reel Weight (lbs) ZDN 1-12 ZDN/20T 1-12

34 x 6.75 x 12 35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5


All Units in Feet

1 70 92 118 140

1,000 14,350 23,926 31,728 48,685

11,918 19,606 25,282 43,324 48,685

2 Flange Clearance

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31


All Units in Feet

70 92 118 140 350 433 580

7,706 12,980 17,195 28,321 32,726 43,439 48,671

14,403 24,286 32,181 48,685 N/A N/A N/A

2 Flange Clearance

Outside Plant Drop (O-DA, O-DN, M-MN and M-DN) Cables


Flange x Drum x Traverse Reel Weight (lbs) DA 1-12 DN 1-12 MMN 1-12 MDN/109 1-6 MDN 1-12

14 x 6.75 x 12 35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31


All Units in Feet 2 Flange Clearance

12 70 92 118 140 350 433 627

N/A 8,498 14,146 18,697 30,251 36,099 44,200 N/A

N/A 7,087 11,861 15,751 26,446 30,945 40,792 48,684

N/A 15,530 26,042 34,948 41,001 N/A N/A N/A

N/A 9,657 16,103 21,560 34,498 N/A N/A N/A

N/A 6,782 11,596 14,957 25,375 28,829 38,469 48,674

Hybrid Loose Tube Non-Armored/Coax (O-DN-HY, M-DN-HY) Cables


Flange x Drum x Traverse Reel Weight (lbs) Fiber + Coax Hybrid DN (1-12F) Self Supporting Fiber + Coax Hybrid DN (1-12F)

35 x 16.5 x 18 42 x 24 x 24 42 x 22 x 29.75 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 31 72 x 36 x 36 78 x 36 x 36


All Units in Feet 2 Flange Clearance

70 109 118 140 350 433 580 627 758

4,998 8,476 11,362 19,262 22,714 29,842 37,946 44,198 N/A

3,791 6,520 8,703 14,817 17,282 22,955 29,017 37,863 44,198

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F70

Fiber Optic Cable


Fiber Optic Cable Products

Packaging and Shipping Information


Low-Smoke Zero-Halogen (LSZH) Distribution (Z-DS) Cables
Fiber Construction 18x12x12 Type FT 22x12x12 FT 30x12x12 FT 35x16.5x18 FT 35x16.5x18 FT 42x24x25 FT 42x22x29.75 FT 48x22x32.5 FT 54x24x28 FT 60x30x32 FT 66x30x32 FT 72x36x36 FT 78x36x36 FT

2 4 6 8 12 18 24 18 24 36 48 60 72

SU SU SU SU SU SU SU MU MU MU MU MU MU

4,090 2,419 1,976 1,583 1,228 N/A N/A N/A N/A N/A N/A N/A N/A

8,991 5,278 4,287 3,418 2,626 N/A N/A N/A N/A N/A N/A N/A N/A

22,563 12,881 10,420 8,294 6,326 N/A N/A N/A N/A N/A N/A N/A N/A

28,000 24,443 19,855 15,862 12,375 10,069 8,393 N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A N/A 2,115 1,737 1,692 1,365 N/A N/A

N/A 28,000 28,000 27,646 21,514 17,289 14,595 3,859 3,271 3,125 2,220 2,043 1,669

N/A N/A N/A 28,000 28,000 23,123 18,966 5,266 4,060 3,919 3,197 2,655 2,162

N/A N/A N/A N/A N/A 28,000 28,000 8,695 6,990 6,262 4,750 4,085 3,466

N/A N/A N/A N/A N/A N/A N/A 9,540 7,885 7,282 5,732 4,547 3,864

N/A N/A N/A N/A N/A N/A N/A 12,822 10,516 9,536 7,619 5,963 5,122

N/A N/A N/A N/A N/A N/A N/A 16,857 13,410 12,302 10,116 8,176 6,639

N/A N/A N/A N/A N/A N/A N/A 21,628 17,120 15,784 12,865 10,536 8,431

N/A N/A N/A N/A N/A N/A N/A 27,141 22,035 20,524 15,381 12,816 11,188

Reel Weights subject to change without notice.

Riser-Rated Distribution (R-DS) Cables


Fiber Construction Type 18x12x12 22x12x12 FT FT 30x12x12 FT 35x16.5x18 FT 35x16.5x18 FT 42x24x25 FT 42x22x29.75 FT 48x22x32.5 FT 54x24x28 FT 60x30x32 FT 66x30x32 FT 72x36x36 FT 78x36x36 FT

2 4 6 8 12 18 24 18 24 36 48 60 72 96 144

SU SU SU SU SU SU SU MU MU MU MU MU MU MU MU

3,553 2,522 2,419 1,976 1,640 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

8,168 5,802 5,278 4,287 3,525 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

20,028 14,170 12,881 10,420 8,866 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

28,000 26,713 24,443 19,855 16,947 10,820 9,097 N/A N/A N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A N/A 3,673 2,529 2,475 2,061 1,699 1,360 N/A N/A

N/A 28,000 28,000 28,000 28,000 18,657 15,669 6,273 4,600 4,531 3,790 2,785 2,215 1,661 1,327

N/A N/A N/A N/A N/A 24,907 20,392 8,058 6,211 5,522 4,728 3,840 3,186 2,150 1,713

N/A N/A N/A N/A N/A 28,000 28,000 13,136 9,912 9,036 7,861 6,154 4,849 3,443 288

N/A N/A N/A N/A N/A N/A N/A 15,714 11,586 10,625 8,854 7,135 5,707 3,968 3,341

N/A N/A N/A N/A N/A N/A N/A 20,784 15,357 14,161 11,710 9,576 7,591 5,245 4,469

N/A N/A N/A N/A N/A N/A N/A 26,930 19,768 18,409 15,571 12,361 10,072 7,340 5,902

N/A N/A N/A N/A N/A N/A N/A 28,000 25,111 23,479 20,078 15,541 12,815 9,278 7,327

N/A N/A N/A N/A N/A N/A N/A N/A 28,000 28,000 25,397 19,248 16,187 11,407 9,224

Plenum-Rated Distribution (P-DS) Cables


Fiber Construction Type 18x12x12 22x12x12 FT FT 30x12x12 FT 35x16.5x18 FT 35x16.5x25 FT 42x24x25 FT 42x22x29.75 FT 48x22x32.5 FT 54x24x28 FT 60x30x32 FT 66x30x32 FT 72x36x36 FT 78x36x36 FT

2 4 6 8 12 18 24 18 24 36 48 60 72 96 144

SU SU SU SU SU SU SU MU MU MU MU MU MU MU MU

4,090 3,050 2,522 2,419 1,696 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

8,991 6,998 5,802 5,278 3,899 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

22,563 17,584 14,170 12,881 9,444 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

28,000 28,000 26,713 24,443 18,048 10,069 9,097 N/A N/A N/A N/A N/A N/A N/A N/A

N/A N/A N/A N/A N/A N/A N/A 4,679 3,302 2,845 2,408 1,745 1,461 N/A N/A

N/A N/A 28,000 28,000 28,000 17,289 15,669 8,067 6,181 4,772 4,023 3,193 2,657 1,717 1,612

N/A N/A N/A N/A N/A 23,123 20,392 10,988 7,968 6,385 5,437 3,982 3,313 2,208 2,104

N/A N/A N/A N/A N/A 28,000 28,000 17,918 13,027 10,820 8,924 6,878 5,488 3,921 3,387

N/A N/A N/A N/A N/A N/A N/A 19,605 14,803 12,337 10,466 7,926 6,408 4,328 3,757

N/A N/A N/A N/A N/A N/A N/A 26,276 19,637 16,589 13,975 10,562 8,461 5,874 4,998

N/A N/A N/A N/A N/A N/A N/A 28,000 25,652 21,158 18,181 13,478 11,067 7,500 6,483

N/A N/A N/A N/A N/A N/A N/A N/A 28,000 26,779 23,227 16,872 14,307 9,459 8,484

N/A N/A N/A N/A N/A N/A N/A N/A N/A 28,000 28,000 20,721 17,888 11,621 10,545

F71

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

Fiber Optic Cable

Packaging and Shipping Information

Fiber Optic Cable Products

Riser, Plenum and LSZH* Simplex (SP) Cables


Fiber Size 18x12x12 FT 22x12x12 FT 30x12x12 FT

1 1 1 1

1.6 2.0 2.5 2.9

19,602 14,364 9,363 6,897

28,000 28,000 20,848 15,824

N/A N/A 28,000 28,000

* LSZH is only for the 2.5 and 2.9 cables.

Riser, Plenum and LSZH* Zipcord (ZC) Cables


Fiber Size 24 x 12 x 19.25 FT 35 x 16.5 x 18 FT

2 2 2 2

1.6 2.0 2.5 2.9

28,000 28,000 21,983 15,965

N/A N/A 28,000 28,000

* LSZH is only for the 2.5 and 2.9 cables.

Riser, Plenum and LSZH* Interconnect (IC) Cables


Fiber Size 18x12x12 FT 22x12x12 FT 30x12x12 FT

2.9

6,897

15,824

28,000

All reels calculated using 2 flange clearance

Reel Weights subject to change without notice.

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

F72

Fiber Optic Cable


Fiber Optic Cable Products

Packaging and Shipping Information


International Packaging - Weights and Dimensions
Reel Dimensions Reels per Layer Layers Cube Size (in.) (l x w x h) Lagging Weight (lbs.) Reel Weight (lbs.) Pallet Weight (lbs.) Total Weight (lbs.)

18 x 12 x 12 18 x 12 x 12 18 x 12 x 12 18 x 12 x 12 18 x 12 x 12 18 x 12 x 12 22 x 12 x 12 22 x 12 x 12 22 x 12 x 12 24 x 12 x 19.25 30 x 12 x 12 35 x 16.5 x 18.5 42 x 22 x 29.75 42 x 24 x 24 48 x 22 x 32.5 54 x 24 x 28 60 x 30 x 32 66 x 30 x 32 72 x 36 x 36 78 x 36 x 36 84 x 40 x 40 88 x40 x 40 96 x 44 x 40

5 5 5 4 4 4 4 4 4 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 2 3 1 2 3 1 2 3 1 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

44 x 44 x19 44 x 44 x 32 44 x 44 x 45 36 x 36 x 19 36 x36 x 32 36 x 36 x 45 44 x 44 x 19.25 44 x 44 x 32.5 44 x 44 x 45.75 36 X 24 X 30 42 x 42 x 19.25 39 X 25 X 41 44 X 40 X 52 44 X 33 X 52 51 x 42 x 58 57 x 42 x 64 63 X 45 X 70 69 X 45 X 75 75 X 48 X 82 81 x 48 x 88 85 x 52 x 92 91 x 52 x 97 not palletized

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 60 189 189 169 188 215 241 333 360 387 414 450

10 10 10 10 10 10 12 12 12 17 22 70 118 109 140 350 433 580 627 758 850 958 1125

32 32 32 23 23 23 32 32 32 32 30 36 43 41 78 78 138 138 197 197 210 210 0

82 132 182 63 103 143 80 128 176 49 52 166 350 339 387 616 786 959 1157 1315 1447 1582 1575

NOTE: Units per container can be limited due to product weight

Reel Weights subject to change without notice.

F73

For more information, call Customer Service at 800.982.1708 or 828.324.2200 Fax 828.328.3400 custserv@commscope.com

You might also like