You are on page 1of 50

MAIN CATALOGUE 2010/11

Measurement technology and high frequency engineering: Research. Development. Industrial Production.

GIGAHERTZ SOLUTIONS
Made in Germany

Measurement technology

HF measurement devices 27MHz - 10 GHz LF measurement devices 5 Hz - 1,000 kHz Data logger

Demand switches

NA comfort series with VDE certificate Ultima series

Protective shielding
Shielding material Socket lines Aero_99 Headset

www.gigahertz-solutions.com

ps

y + py pl p p T1 u u C S , ics Lam er S kers ics er r -T T n n s e w B o w o e o e g V B w o o g n m n Po rm DV , T DV eli lta ar avi g P n C Po a , g o d o i , H i 0 n S n o V u lH hin ad RA s ial gy tchi cti tio 90 G c ra N ar R t n c c i i r u u i d A T M , t a i O a e w L E S Tr Ra ... ... M ... Na ... Art En Sw Ind ... CB T ... G TC ... S ... ... D e T av C w E o ,D icr 0 M 0 18 N / AX N M LA SM LA I G W W W r da a R
10GHz 2,5 GHz 7 GHz 100KHz 400KHz 1MHz 3 MHz 27MHz 800MHz 1 GHz

0 5Hz 16Hz

50 Hz

2KHz 30KHz

Low Frequency
HF 32D HF 35C HF 38B HFE 35C HFEW 35C HF 58B HF58B- r

High Frequency

ME 3030B

ME 3830B

1D

ME 3840B

ME 3851A

ME 3951A

set consisting of HFE 35C and HFW 35C

HFE 59B

professional line

3D-LF-Analyser with data logger


HFW 35C

NFA 30M

NFA 400

HFW 59B in planning stage

NFA 1000
www.gigahertz-solutions.de
Last update: 05/2011

About Us

Page 4 6 10 20 30 36

HF Measurement Technology LF Measurement Technology Protective Shielding Demand Switches Product Tables

With the release of this catalogue all former prices become invalid.

-3-

Demand Switches

Shielding

40

LF - Technology

Measurement Kits

HF - Technology

Content

Measurement Kits

About us...

Head Office of Gigahertz Solutions GmbH in Langenzenn / Germany

...upper floor only!

Founded: 1997 Registered Office: 90579 Langenzenn, Am Galgenberg 12, HRB 6459 Frth/Bayern/Deutschland Managing Partners: Dipl. Wi.-Ing. Niels Dernedde and Dipl. Ing. Thomas Lorenz Fields of Activity: Development and production of high frequency and low frequency field strength measurement technology, as well as demand switches (11 patent registrations, 12 further patent applications (update: spring 2010) ) Technical Equipment: State-of-the-art measurement and testing technology for laboratory use as well as for the production reaching up to 30 GHz from worldwide leading producers: - For the high frequency: single and multiple signal source with frequency synthesizer for all relevant transmission protocols (GSM, UMTS, WIMAX, WLAN etc.), spectrum analysers, scalar analysers, and network analysers - Antenna test station in accordance with the pan-European standards of the absolute method (quasi free-space conditions) - For the low frequency: FFT-analyser, 100 MHz oscilloscope, 4 m plate capacitor, Helmholtz-reels up to 400 kHz ...and of course anything you need concerning the hard- and software (simulation tools, etc.) as well as for the mechanical processing! Fully automatic SMD component insertion machine with up to 5000 pieces per hour (ROHS compliant)

Quality Management As our demand switches have been awarded the VDE-mark (VDE = German Association for Electrical, Electronic & Information Technologies), our quality management has to undergo an annual control by VDE-staff members. Our OEM customers Berker, Eltako, Gira, Jung, Legrand, Schrack and Schupa/Gewiss have also tested and approved our quality management.

-4-

... and our values


We develop and produce our measurement instrumentation ourselves A multitude of granted patents as well as applications for patents are a guarantee for our progressive devices, the potentials of which by far exceed the stateof-the-art technology. Most modern production techniques as well as our qualified personnel ensure constant high quality and an excellent price-performance ratio. Tens of thousands of high and low frequency analysers have delivered an optimal and reliable performance with measurement technicians in the biological construction consultancy, with citizens action groups, with doctors, companies, and private users in all of Germany and Europe, and even worldwide . Customer satisfaction is one of our main aims, therefore of course all our products come with the statutory two-year full warranty. Furthermore we grant a longtime ex gratia agreement How long is long-time? Well, we dont really know ourselves In any case, we havent issued a repair invoice since our foundation in 1997. The official upgrade-promise: We want clear terms! Upon purchase of a more expensive measurement device of the same product category, you may return your old device and will only be charged the corresponding price difference plus an allowance for utilization and depreciation calculated according to the age of the returned device. This upgrade-promise applies for all low and high frequency analysers up to two years of age. For details see Measurement. If your device is already older than two years, please contact us for a specific offer.

Quality & Service

GIGAHERTZ INTERNATIONAL

-5-

Please note the following updates to our catalogue:


Page 2 2 11 12 15 16 17 17 17 26 28 31 32 Product HFEW 47C HFW 59B MW1 HF38B HFW35C FF3 & FF6 VF4 DG20_G10 HV10_27G3 NFA 400M PM4s AERO_99 ST-Naturell Update To be replaced by HFEW35C (EUR 1066; combi of HFE35C & HFW35C) Production planned for 2012 No longer available Transport case not part of the supply Audio Analysis for WLAN, WiMAX and Microwave No longer available No longer available Also suitable for HFW 35C Also suitable for HF 58B, HF 58B-r, HFE 35C Will not be produced Price: EUR 84.20 incl. VAT No longer available Attenuation of 35 dB instead of 40 dB

Measuring Kits
Set offers with a substantial price point vs. purchase of individual devices In our surroundings, high and low frequency occur totally independently from one another. Their physical characteristics have differing impacts on the body, and specific measuring technology is required for an exhaustive and satisfactory detection.

Common Advantages of our Measurement Technology:


Made in Germany just like the complete field strength measuring technology from Gigahertz Solutions: * Development, production, quality management, consultancy, service the all-in-one solution. Metrologically outstanding in all price categories from below 100 to over 2,000 Euro. Innovative, in many cases patented circuit elements ensure a reliable performance of all devices: * Extremely high linearity right down to the lowest scale limit (Patents DE19809784 and DE10317805) * Fully compensated frequency responses allowing informative measurement results The devices are equipped with an LC-display showing the total exposure within the measured frequency range, directly in the unit corresponding to the building biologys recommended safe values. This allows an easy evaluation of the personal exposure, as well as a determination of suitable remedial actions, and a control of their effectiveness. The scope of supply includes a battery, further accessories and a detailed instruction manual, so you can start measuring immediately upon receipt. Useful details are a standard implementation, such as an acoustic signal proportional to the field strength, a lowbatt.-indication, and the battery saving auto-power-off.

-6-

Electrosmog measuring kit MK10

for an easy evaluation of your personal exposure

Combines all "common advantages"

This solid basic equipment, consisting of an HF32D and an ME3030B, allows for a reliable interpretation of the personal exposure to HF and LF electrosmog on the basis of acknowledged measurement procedures. For detailed specifications of the devices please refer to the respective product descriptions.

Scope of delivery: HF32D, ME3030B incl. accessories, compact transport case

Electrosmog measuring kit MK20

for an easy evaluation of your personal exposure

Combines all "common advantages".

Contains the instruments ME3830B and HF35C. Allows an easy evaluation of the personal exposure to HF and LF electrosmog according to the guidelines and recommended safe values of the "Standard of Building Biology Measuring Techniques" ( Maes, IBN). The HF-device includes the very useful feature of an acoustic analysis for a reliable identification of the various pulsed HF sources, and the LF-device has an extended frequency range designed to also measure the artificial harmonics. For detailed specifications of the devices please refer to the respective product descriptions.
Scope of delivery: HF35C, ME3830B incl. accessories, transport case

Electrosmog measuring kit "Profi" MK30

The link between the amateur and the professional instruments

Combines all "common advantages".

The devices contained in this measuring kit are a perfect combination of the easily operated devices for technical amateurs with the additional analytical possibilities offered by the devices for professional evaluations. This is the top-selling kit for doctors and healers looking for a competent overview over the total emf-pollution either for themselves or for their patients, but who neither have the daily practice nor the time to get acquainted in the necessary manner with the technology of a professional measurement device. The HF38B, for instance, already features the frequency range, the peak-hold function and the antenna of the professional series. And the ME3840B is already equipped with the switchable frequency filter for a clear differentiation of traction supply and mains supply as well as the corresponding artificial harmonics. The devices come well protected in a plastic case with shaped foam filler for a safe transportation.
Scope of delivery: HF38B, ME3840B incl. accessories, transport case

Electrosmog measuring kit "Profi" MK60-3D

for the professional analysis

Professional equipment with a worthwhile price point.

The professional equipment for building biologists for the high and low frequency. The NFA400 allows for a frequency range extended to the full TCO band width within the low frequency and includes a data logger. The HF58B-r is equipped with an additional internal switching module for especially precise measurements of radar and UMTS-FDD.

Scope of delivery: HF58B-r, NFA-400, incl. accessories, transport case

-7-

Measuring Kits

Measuring Kits

Electrosmog measuring kit "Profi" MK70-3D

for the professional analysis

Professional equipment with a worthwhile price point. This set consits of our two top models, the NFA1000 and the HFE59B. The quasiisotropic antenna of the HF-device has special advantages for the building biology immission measurements, the identification of so-called hot spots, and additionally extends the analysed frequency range down to 27 MHz. It therefore also includes the TV- and radio-frequencies, as well as the TETRA standards which are to be introduced all over Europe. The NFA1000 with its 3D sensors for E & M, FFT analysis, and data logger is definitely a convincing instrument.
Scope of delivery: HFE59B, NFA1000, incl. accessories, transport case

Electrosmog measuring kit "Profi plus" MK70-3D plus1.0

for the professional analysis

Professional equipment with a worthwhile price point. The MK70-3D with the following additional devices: HFW35C (2.4 - 6 Ghz) FF6E selective frequency filter TCO3 probe for the NFA1000 PM4 potential-free holder Capacious aluminium transport case

Scope of delivery: HFE59B, NFA1000, HFW35C, FF6E, TCO3, incl. accessories, aluminium case

Demonstration kit "Profi" DK20

for professionals in terms of "electrosmog"

A complete selection of useful demonstration items. Important for courses, lectures, trade fairs, or explanations during house examinations. 50% discount (= 299 Euro) for all who work related to the electrosmog subject, be it as a building biologists, be it in healing or teaching professions. (proof required, can be ordered only once per person!)

Scope of delivery: 1 demand switch demo set NA-DEMO, 10 polarisation gaugers MFP, 3 shielded socket lines SLS4000, 2 low-heat device power cables KAS-0006, 1m shielding material N-80, 1 low radiation headset Aero_99, 1 set of adapters Adabundle, 1 aluminium case

Ask for your INDIVIDUAL i-Set

... the COMPLETE range at a worthwile price point

Are you absolving a building biology training and looking for a customised set for the start of your career? Do you just want to be on the safe side? Are you electrosensitive? Do you have special demands? Whatever - just send us an e-mail with your special choice of devices, and we will be pleased to calculate a special individual set offer for you!

-8-

Plastic transport case K5

fits one or two devices (with small antenna)

Universal transport case with 2 shaped foam filler inserts, dimensions: approx. 33 x 27 x 8 cm.

Scope of delivery: Transport case with foam filler inserts for various types of devices

Plastic transport case K2

fits one HF and one LF device of any type

Universal transport case with shaped foam filler inserts, dimensions: approx. 33 x 27 x 16 cm.

Scope of delivery: Transport case with inserts

Aluminium case K3

For a safe storage and transportation of several instruments

Transport case with brushed aluminium surface. Dimensions: approx. 52 x 40 x 21 cm. Contains flexible and variable padded compartments to protect your valuable equipment.

Any questions regarding your individual measuring kit? Just give us a call! Hotline : +49 9101 90 93 - 0

-9-

Measuring Kits

HF Measurement Technology
For the evaluation of high frequency radiation from 27 MHz to 6 GHz (to be amplified to 3 Mhz - 10 GHz in 2010), a range comprising frequencies from radio and TV (digital as well as analogue), TETRA (digital public safety networks), microwave radio relay, GSM mobile radio, radar, DECT cordless telephones, UMTS mobile radio, Wi-Fi, WLAN, microwave ovens, WiMAX.

HF-Technology

S Ra hor t RF dio Wa ID , P ve ow , A er m lin at e eu (P r LC ), CB Ra TE dio TR , R A ad , D io VB , TV G SM -T 90 0, DV BRa T, CT da r 1+ G SM W 180 LA 0, N D / M EC icr T ow W IM av e W AX LA N


... ... ... ...
27MHz 800MHz 1 GHz 2,5 GHz

...

3MHz

6 GHz 10GHz

Common Advantages:
Made in Germany just like the complete field strength measuring technology from Gigahertz Solutions: * Development, production, quality management, consultancy, service the all-in-one solution. All our devices, even the most inexpensive ones, are reliable meters of the much discussed pulsed radiation as caused by GSM mobile radios, DECT cordless telephones, WLAN, and others, as well as, of course, of the un-pulsed radiation between 800 MHz und 2.5 GHz. They are equipped with a digital measured value display which shows the total exposure within the measured frequency range, directly in the entity corresponding to the building biology standard values (W/m), without error-prone add-ups, thus allowing a straight forward assessment of the exposure, as well as a determination of suitable remedial actions, and a control of their effectiveness. All devices come with a mechanically stable, logarithmic-periodic measuring antenna with excellent directionality, allowing a reliable location of the source of radiation qualified according to the panEuropean standards of the so called absolute method under quasi free-space conditions (patent no. DE10352175). Innovative, in many cases patented circuit elements ensure a reliable performance of all devices: * The self aligned HF-entry circuit: eliminates the temperature- or age-dependent zero deviation of these sensitive components. (Patent DE10317805) * The antenna curve is fully compensated, and falsifying influences from radiation sources below the specified frequency range are inhibited by a steep-sided high pass filter. * Extremely high linearity right down to the lowest scale limit. (Patents DE19809784 and DE10317805). Useful details are a standard implementation, such as an acoustic signal proportional to the field strength, a lowbatt.-indication, and the battery saving auto-power-off.

- 10 -

Ra d

ar

RF-Analyser HF32D

for an easy evaluation of the HF exposure This is the device for technical amateurs - especially easy to operate. It allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness. Even this starter device already combines all common advantages. The reading shows the total pollution without any calculation required. The measured values are reliably displayed directly in the entity corresponding to the building biology standard values. An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps identifying regions with increased exposure. Digital display of 1 W/m up to 1999 W/m.
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable, alkaline manganese battery, detailed instructions manual with factual background information

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 800 MHz - 2.5 GHz Power flux density: 1 - 1999 W/m Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits Logarithmic periodic antenna acoustic signal proportional to the field strength with "Geiger-counter-effect" peak value 9 Volt alkaline manganese battery (included), average operation time 10 - 12 hours Low-Batt. indication, auto-power-off

RF-Analyser HF35C

for an easy HF evaluation, incl. audio analysis This is THE device for technical amateurs - especially easy to operate. It supports all above mentioned "common advantages" and it allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness. Has the same features and configuration as the HF32D, however additionally offers Audio analyses for the identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency. Display of peak value as well as average value (switchable). Sensitivity increased by a factor of 10 (from a minimum display resolution of 0.1W/m to a maximum of 1999 W/m). HINT: Our best-selling meter for the easy evaluation!
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable alkaline manganese battery, detailed instructions manual with factual background information

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 800 MHz - 2.5 GHz Power flux density: 0.1 - 1999 W/m Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits Logarithmic periodic antenna Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control-radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value as well as average value (switchable) 9 Volt alkaline manganese battery (included), average operation time 6 - 7 hours Low-Batt. indication, auto-power-off

- 11 -

HF-Technology

RF-Analyser HF38B

The link between amateur and professional instruments This device supports all above mentioned "common advantages". It is especially popular among medics and alternative practitioners, as it offers a perfect combination of easy handling and professional measurement possibilities. It allows an easy allocation of the electrosmog frequencies to the traction power or the mains power as well as to the artificial harmonics, thus facilitating an especially precise consultation of remedial actions and an easy control of their effectiveness. Has the same features and configuration as the HF35C, however additionally offers some important professional features: The log.-per. antenna with further improved frequency response. A 10 times higher sensitivity: Minimum display resolution 0.01 W/m . A measuring range extended upwards by a factor of 10: max. 19.99 mW/m . Clearly simplified measurements with the help of the "peak-hold"- function.
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable Alkaline Mangan battery, detailed instructions manual with factual background information

HF-Technology

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 800 MHz - 2.5 GHz (3.3 GHz with increased tolerance) Power flux density: 0.01 - 19,990 W/m Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits Optimised logarithmic periodic antenna: Less ripple, better directionality, improved shielding vs. ground Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value, peak hold as well as average value (switchable) 9 Volt alkaline manganese battery (included), average operation time 6 - 7 hours Low-Batt. indication, auto-power-off

RF-Analyser HF58B

for the professional HF analysis This device represents the low cost access to the professional high frequency broadband measurement technology. Its functions and features are tailored to the needs and practical experiences of the building biology. In addition to the full functionality of the HF38B: A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology (based on our patent DE10317805) A NiMH battery, a battery charger and a power supply unit inclusive An AC- and a DC-output (AC: demodulated signal) LEDs monitoring the function of the antenna
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable, NiMH battery inside the meter, mains adaptor, battery charger, various adaptors,detailed instructions manual, plastic case.

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Signal output ports: Power supply: 800 MHz - 2.5 GHz (3.3 GHz with increased tolerance) Power flux density: 0.01 - 19,990 W/m Basic accuracy including linearity tolerance : +/- 4.5dB Zero offset and rollover +/- 7 digits Optimised logarithmic periodic antenna: Less ripple, better directionality, improved shielding vs. ground Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control-radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value, peak hold as well as average value (switchable) A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology An AC- and a DC-output (AC: demodulated signal) Rechargeable highpower 9.6 Volt NiMH battery pack inside the meter, average operation time: 7 - 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included

- 12 -

RF-Analyser HF58B-r

RADAR-/Crest-optimised version of the HF58B The radar module sets standards in this category of devices. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes, especially in the cell phone and wireless sector. In addition to the full functionality of the HF58B: A switch for 2 MHz video bandwidth, allowing especially precise measurements, also of ultra short RADAR signals within the frequency range subject to measurement with a minimum pulse length of up to 0.5 micro seconds, as well as of UMTS-FDD/3G. Especially high speed of response in the operational mode "peak hold" (patented).
Scope of delivery: Measurement device, attachable log.-per. antenna, incl. cable, NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instructions manual, plastic case.

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Signal output ports: Power supply: 800 MHz - 2.5 GHz (3.3 GHz with increased tolerance) Power flux density: 0.01 - 19,990 W/m Basic accuracy including linearity tolerance : +/- 4.5dB Zero offset and rollover +/- 7 digits Optimised logarithmic periodic antenna: Less ripple, better directionality, improved shielding vs. ground, continuous LED-monitoring of quality of connections Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value, peak hold as well as average value (switchable) A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology An AC- and a DC-output (AC: demodulated signal) Rechargeable highpower 9.6 Volt NiMH battery pack inside the meter, average operation time: 7 - 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included

RF-Analyser HF59B

Our first class HF-device Due to its extra broad frequency response, this basic device is predestined for an extension with the UBB27 and for detailed, professional analyses. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes - mostly as kit called HF E 59B especially in the sector of EMVU and product development (precompliance). In addition to the full functionality of the HF58B-r: A frequency range of down to 27 MHz within the basic device - suitable for the connection of the optionally available antenna UBB27_G3 (the scope of delivery includes a compensated antenna for 800 MHz up to 2.5 or 3.3 GHz). A calibrated extra AC-measurement output for the demodulated signal, and a scalable DC-output. HINT: If you only need to measure above 800 MHz the HF58B-r is the cheaper and better solution for you. Only with the antenna UBB27 (included in the kit HFE59B) you can in fact measure frequencies below 800 MHz (e.g. digital TV, TETRA, new GSM Channels in Europe).
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable, NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instructions manual, plastic case.

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Signal output ports: Power supply: A frequency range of down to 27 MHz within the basic device - suitable for the connection of an optionally available antenna (the scope of delivery includes a compensated antenna for 800 MHz up to 2.5 or 3.3 GHz) Power flux density: 0.01 - 19,990 W/m Basic accuracy including linearity tolerance : +/- 3dB Zero offset and rollover +/- 5 digits Optimised logarithmic periodic antenna with frequeny compensation directly on the antenna: Less ripple, better directionality, improved shielding vs. ground, continuous LED-monitoring of quality of connections Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value, peak hold as well as average value (switchable) A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology A calibrated extra AC-measurement output for the demodulated signal, and a DC-output Rechargeable highpower 9.6 Volt NiMH battery pack inside the meter, average operation time: 7 - 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included

- 13 -

HF-Technology

RF-Analyser kit HFE35C

for an easy evaluation, incl. UBB-antenna It supports all above mentioned "common advantages". The extra-broad frequency response of the UBB27 together with the features and specifications of the HFE35C offer an outstanding overview over the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness. Set offer including the following components: The instrument itself, based on the HF35C but with an extended frequency range reaching down to 27 MHz. Two antennas: The especially compensated log.-per. antenna for the range above 800 MHz, and the horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to far beyond 2.5 GHz (limited by the frequency response of the HFE35C). Small plastic case K5: with convoluted foam filler for a safe transportation of the measuring device and both antennas.
Scope of delivery: Measurement device, log.-per. and UBB antenna, alkaline manganese battery, detailed instructions manual with factual background information, plastic case.

HF-Technology

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 27 MHz - far above 3.3 GHz Power flux density: 0.1 - 1999 W/m Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits Logarithmic periodic antenna with frequeny compensation directly on the antenna Quasiisotropic ultrabroadband antenna ("omni"-characteristic) aligned for vertically polarised fields Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value as well as average value (switchable) 9 Volt alkaline manganese battery (included), average operation time 4 - 7 hours Low-Batt. indication, auto-power-off

RF-Analyser kit HFE59B

Our first class HF-device including UBB antenna and accessories This kit, based on the HF59B, offers an excellent dynamic response of approx. 93 dB. The innovative functions of the basic device HF59B in combination with the broad frequency response of the UBB27 offers outstanding possibilities for the evaluation of high frequency. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes, especially in the sector of EMVU and product development (precompliance). Set offer consisting of the HF59B and a wide range of accessories: Horizontal isotropic ultra broad bandwidth antenna UBB27_G3 from 27 MHz up to beyond 3.3 GHz (limited by the frequency response of the HF59B). 800 MHz high pass filter HP800_G3 for the suppression of low frequencies when measuring with the log.-per. antenna of the HF59B. High frequency preamplifier HV10_27G3. Increases the measurement range by 10 dB (by a factor of 10) - important when wanting to reduce the increased noise background in the radar or UMTS/3G-mode. Attenuator DG20_G3: Increases the maximum measurable value by 20 dB (or by a factor of 100) to 1,999 mW/m (= 1.999 W/m). Plastic case K2 with shaped foam filler for a safe transportation of all components. Offers enough space for yet another Gigahertz Solutions measuring device (high frequency or low frequency).
Scope of delivery: Measurement device, log.-per. and UBB antenna, NiMH battery inside the meter, mains adaptor / battery charger, high pass filter HP800, high frequency amplifier HV10, attenuator DG20, various adaptors, detailed instructions manual, comes in a plastic case

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: 27 MHz - far above 3.3 GHz Power flux density: 0.001 - 1,999,000 W/m (i.e. 1 nanoW/m nominal display resolution to 1.999 W/m when applying the amplifier and attenuator enclosed) Basic accuracy including linearity tolerance : +/- 3dB Zero offset and rollover +/- 5 digits 2 antennas: Optimised logarithmic periodic antenna with frequeny compensation directly on the antenna: Less ripple, better directionality, improved shielding vs. ground, continuous LED-monitoring of quality of connections Quasiisotropic ultrabroadband antenna ("omni"-characteristic) aligned for vertically polarised fields Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value, peak hold as well as average value (switchable) A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology A calibrated extra AC-measurement output for the demodulated signal, and a scalable DC-output Rechargeable highpower 9.6 Volt NiMH battery pack inside the meter, average operation time: 7 - 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included

Audio Analysis: Signal rating: Signal output ports: Power supply:

- 14 -

RF-Analyser HFW35C

widens the range of analysis up to 6 GHz The "common advantages" are fulfilled by this instrument for the specified frequency range. As simple to operate as the HF35C. Its functions and features are tailored to the needs and practical experiences of the building biology. Due to its comparably low price, it is often also used by computer retailers, authorities and industry for dimensioning of WLAN-networks. Functionality similar to the HF35C, however: Frequency range from 2.4 to 6 GHz. A special device suitable for the measurement of radiation caused by wireless applications / computer networks, including the new standards (Bluetooth, WLAN, WiFi), also covering the WiMAX-frequencies auctioned off in 2006. It comes with an especially aligned log.-per. antenna with excellent directivity (Patent pending: AZ 10 2006 051 180.8 ). It suppresses frequencies from mobile radios and DECT by means of a steepsided high pass filter integrated into the antenna to avoid falsified measurements of the frequency range from 2.4 to 6 GHz. The instrument is equipped with the switch of the professional line for quantitative differentiation between pulsed and un-pulsed radiation.
Scope of delivery: Measurement device, attachable log.-per. antenna incl. cable, alkaline manganese battery, detailed instructions manual with factual background information

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 2.4 - 6.0 GHz Power flux density: 0.1 - 1999 uW/m Basic accuracy including linearity tolerance : +/- 6dB Zero offset and rollover +/- 9 digits Optimised logarithmic periodic antenna with frequeny compensation directly on the antenna, better directionality Identification of pulsed radiation sources (mobile radio (GSM, UMTS/G3), cordless telephones (DECT), WLAN (Bluetooth), air-traffic control radar) by means of an acoustic signal proportional to the modulation frequency Display of peak value as well as average value (switchable) A quantitative differentiation between pulsed and un-pulsed radiation - a unique feature within the broadband measuring technology 9 Volt alkaline manganese battery (included), average operation time 6 - 7 hours Low-Batt. indication, auto-power-off

- 15 -

HF-Technology

Service-specific frequency filter FF3

Recommended for: HF35C, HF38B

The service specific filters always only show the preset radio service, and suppress all other frequencies. Evaluates each radio service separately To be connected between the antenna cable and the antenna input socket of the measurement device (by the operator). Cascadable with all amplifiers and attenuators. Also allows a broadband measurement without additional transmission loss, which means the filter can remain attached to the measurement device. Comprises the most common sources of radiation.Very good selection of the chosen radio services. Possible exposures to sheath currents on the cable behind the filter can be additionally suppressed with the help of a free of charge modification of your HF-device. Please do not hesitate to contact us.
Scope of delivery: filter, tightening aid, manual Technical data:
Frequency Range: Accuracy: Power supply: ALL / GSM9 / GSM18 / DECT / UMTS / WLAN Typical suppression of unwanted frequencies : > 25-30 dB, GSM1800 vs. DECT eff. 20-30 dB. 9 V battery

HF-Technology

Service-specific frequency filter FF6

Recommended for: HF58B, HF58B-r

Accessories

The service specific filter always only shows the preset radio service and suppress all other frequencies. Evaluates each radio service separately Additional features as compared to the FF3: The 50-60 dB suppression of unwanted frequencies is unequalled in this product segment. It allows for a precise analysis of the selected frequency ranges. An additional high pass filter applied at 1100 MHz helps differentiating in areas with high levels in the TV bands. To be connected between the antenna cable and the antenna input socket of the measuring device (by the operator). Cascadable with all amplifiers and attenuators. Also allows for a broadband measurement without additional transmission loss, which means the filter can remain attached to the device. Perfectly shielded against interferences. Possible exposures to sheath currents on the cable behind the filter can be additionally suppressed with the help of a free of charge modification of your HF-device.
Scope of delivery: filter, RG58 coaxial cable, tightening aid, manual, charger. Technical data:
Frequency Range: Accuracy: Power supply: ALL / GSM9 / GSM18 / DECT / UMTS / WLAN / HP11 Typical suppression of unwanted frequencies: > 50-60 dB, GSM1800 vs. DECT eff. 20-30 dB. 9 V NiMH battery, average time of operation: 8 hours, Low-Batt. indication, auto-power-off-function, mains adaptor, battery charger

Service-specific frequency filter FF6E

Recommended for: HF E 35C, HF E 59B

The service specific filters always only show the preset radio service, and suppress all other frequencies. Evaluates each radio service separately Additional features as compared to the FF6: The 50-60 dB suppression of unwanted frequencies is unequalled in this product segment. It allows for a precise analysis of the selected frequency ranges. With its additional filters for TETRA-BOS, DVB-T, as well as high and low pass combinations applied at 1100 MHz this filter is especially suited for our E-type measuring devices (as from 27 MHz). To be connected between the antenna cable and the antenna input socket of the measuring device (by the operator). Cascadable with all amplifiers and attenuators. Also allows for a broadband measurement without additional transmission loss, which means the filter can remain attached to the device. Perfectly shielded against interferences. Possible exposures to sheath currents on the cable behind the filter can be additionally suppressed with the help of a free of charge modification of your HF-device.
Scope of delivery: filter, Rg58 coaxial cable, tightening aid, manual, charger. Technical data:
Frequency Range: Accuracy: Power supply: ALL / GSM9 / GSM18 / DECT / UMTS / WLAN / HP11/ TP11 /TETRA / DVB-T Typical suppression of unwanted frequencies: > 50-60 dB, GSM1800 vs. DECT eff. 20-30 dB. 9 V NiMH battery, average time of operation: 8 hours, Low-Batt. indication, auto-power-off-function, mains adaptor, battery charger

- 16 -

Variable frequency filter (trap) VF4

suitable for any HF-Analyser as from HF35C

For a "what-if" analysis prior to shielding measures. Variable frequency filter (suppression 40 dB = factor 10,000) for a simplified differentiation of the HF radiation sources between 700 and 3000 MHz. To be connected between the antenna cable and the antenna input socket of the measuring device (by the operator). No battery needed. In combination with the HF59B or the HFE35C, the variable frequency filter should only be used together with the log.-per. antenna and the HP800, if possible.

Attenuator DG20

suitable for: HF32D, HF35C, HF38B Allows a measurement of major exposures. For high exposures Reduces the sensitivity of the measuring device by a factor of 100 (= 20 dB). Adaptor plug to be connected to the antenna input socket.

Attenuator with DC-Bypass DG20_G10

suitable for: HFE35C, HF58B, HF58B-r, HF59B, HFE59B

For the measurement of major exposures. In addition to all features of the DG20: enhanced frequency linearity and DC-bypass.

RF-preamplifier HV10_27G3

suitable for: HF59B, HFE59B Increases the sensitivity of the HF-analyser by a factor of 10 (= 10 dB), that is nominal 0.001 W/m*. Adaptor plug to be connected to the antenna input socket, remote-fed by the respective basic device. It is especially recommended for the HF59B for measurements in the highly sensitive measuring range of the radar and UMTS mode. Future-proof: Comprises the full frequency range of the HF59B. In order to avoid measurement errors due to intermodulations, a high pass filter matching to the antenna (such as the HP800) should be applied when measuring with the log.-per. antenna. * The actual sensitivity is limited by the device-specific residual noise of the HF-analyser.

- 17 -

Accessories

HF-Technology

RF-preamplifier HV20_2400G10

suitable for: HFW35C, HFW59B

Increases the sensitivity of the HF-analyser by a factor of 100 (= 20 dB). Adaptor plug to be connected to the antenna input socket, remote-fed by the respective basic device.

HF-Technology

RF-preamplifier HV30_27G3

suitable for: HF58B, HF58B-r, Hf59B

Increases the sensitivity of the HF-analyser by a factor of 1000 (= 30 dB). Adaptor plug to be connected to the antenna input socket, remote-fed by the respective basic device.

Accessories

High-pass filter HP800_G3

suitable for: HFE35C, HF59B, HFE59B The HP800 increases the measuring accuracy when measuring with the log.-per. antenna in combination with the extremely broad band devices HFE35C and HF59B(Filter included in the scope of supply of the HFE59B). Why? The log.-per. antennas are sensitive also for individual frequencies below the specified frequency range. These can be successfully suppressed with the filter, which in turn allows a significantly improved analysis of the measurements with a log.-per. antenna, as the measurements are not impaired by unidentified interference signals. This filter helps suppress the lower frequencies. It reaches an attenuation of more than 50 dB (= factor 100,000) below 600 MHz. All Gigahertz analysers specified above 800 MHz already come with a similar filter integrated in the basic device. This integration naturally makes no sense for the HFE-types. Adaptor plug to be connected to the antenna input socket.

Ultra broadband antenna for RF-Analysers UBB27_G3

suitable for: HFE35C, HF59B, HFE59B The outstanding parameters with regard to the frequency linearity and the responsivity render this antenna a very useful equipment for broadband measuring devices for the definition of the total exposure to high frequency radiation. From 27 MHz to far beyond 3.3 GHz*: For the measurement of the primary high frequency ranges: CB and amateur radio, directional radio, TV and radio (digital and analogue), TETRA, GSM, radar, DECT, UMTS, WLAN, and more. "Overall (non-directional) reception": Horizontal isotropic directional pattern - a fundamental feature for long-term measurements. Compact construction: Identifies so-called "hot spots". To be attached directly onto the HFE35C or the HF59B. * Limited in real terms by the frequency response and specifications of the respective HF analyser.

- 18 -

Quasi isotropic ultra broadband antenna UBB27-SA3

suitable for: spectrum analysers

UBB27_G3 incl. accessories designed for measurements with spectrum analysers_G3. DC input element, antenna mounted on plastic housing, including adapters and antenna cablel

Bearing antenna LAT10

suitable for: all HF analysers Please note: not suitable for exact quantitative measurements! Due to its very narrow directional characteristics, some sources of radiation can easily be "overlooked" as the antenna is not compensated and shows far too high values. Very simple log.-per. antenna with extremely narrow directional characteristics. Especially suited for the identification of (even concealed) sources of radiation.

Scope of delivery: Bearing antenna with approx. 1 m of antenna cable and SMA connector

Bearing antenna below 900 Mhz LAT170

suitable for all HF analysers

Similar to the LAT10, but for the lower frequency range of 170 MHz to 900 Mhz, ideal for the location of, for example, DVB-T. (Adequate only for location purposes - not for proper measurement evaluations).

Silicon holster (protective sheath) black HOL2

Protection and professional outfit!

for 3D LF and HF series colour: black (delivery without measuring device)

- 19 -

Accessories

HF-Technology

LF Measurement Technology
For the measurement of low frequency alternating magnetic and electric fields caused, for instance, by the domestic mains supply and the devices connected to it, by switches and lights, by high-voltage lines, transformer stations and traction power.

0 5Hz 16Hz 50 Hz 2KHz 30KHz

LF-Technology

Po M we ain r s Vo lta Na ge tu ra lH ar Ar m on En tific i ics e a Sw rg l H itc y-s ar hin av mo g in n Ind Po g L ics uc we am tio r S p n u Co pp ok ly er s TC O G uid eli Sw ne itc hin g Po we rS up
... ... ... ... ...
100KHz 400KHz 1MHz

Tra

ct ion

Decision support: ME- series or NFA-series?


I would like to analyse my exposure to low frequency electromagnetic pollution at home or at work for my own purpose and at a reasonable price. * Even our two low-priced devices of the ME-series meet all common advantages of our measurement technology, and therefore have an excellent price-performance ratio. The frequency responses and the accuracy of these devices allow convincing measurement value comparisons with the recommended standards of the building biologists. I want exact and detailed results, and might also be interested to offer measurements for others as a service. * The devices of the ME-series by far exceed the state of the technology in this price class, and thus set standards. They are easy to use and comparatively low-priced, but require clearly more time for measurements (one-dimensional measurements), and allow less detailed results. I am a measurement technician or in technical training in the field of geobiology or building biology, and am interested in equipment which will optimally support my work. * The innovative and groundbreaking concept of the NFA-series will allow an all-time combination of an efficient three-dimensional measurement and long-term recording, a complete documentation of all relevant aspects of the field situation, as well as a comfortable evaluation on your PC (for further information please see further on in the catalogue).

- 20 -

pl

Low frequency analyser ME3030B

for an easy evaluation of LF-exposure

This is the device for technical amateurs - especially easy to operate. It allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness. Even this starter device already comprises all common advantages - the only one of ist kind in this price category. The reading shows the total pollution without any calculation required. The measured values are reliably displayed directly in the entity corresponding to the building biology standard values, namely: The electric field strength from 1 to 1999 V/m (against ground potential) The magnetic flux density from 1 to 1999 nT. An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps identifying regions with increased exposure.
Scope of delivery: Measurement device, grounding cable, alkaline manganese battery, detailed instructions manual with factual background information Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 16 Hz - 2 KHz (compensated, better than -2 dB) Magnetic flux density (unidimensional): 1 - 1999 nT Electric field strength: 1 - 1999 V/m +/- 2 %, +/- 20 digits @ 50/60 Hz E-field sensor for electrical LF- fields H-field sensor for magnetic LF-fields (one-dimensional) acoustic signal proportional to the field strength with "Geiger-counter-effect" RMS 9 Volt alkaline manganese battery (included), average operation time 24-36 hours Low-Batt. indication, auto-power-off

Low frequency analyser ME3830B

for an easy evaluation of LF-exposure

This is THE device for technical amateurs - especially easy to operate. It supports all above mentioned "common advantages" and it allows a straight forward assessment of the exposure, a determination of suitable remedial actions, as well as a control of their effectiveness. Comprises all features of the ME3030B, and additionally offers: A clearly extended frequency range: from 5 Hertz to 100 Kilohertz. This frequency range (in accordance with SBM) also includes the higher frequencies caused by, for instance, energy saving lamps, switching-mode power supplies, electronic dimmers, or monitors, which are considered especially critical.
Scope of delivery: Measurement device, grounding cable, alkaline manganese battery, detailed instructions manual with factual background information Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 16 Hz - 100 KHz (compensated, better than -2 dB). Magnetic flux density (unidimensional): 1 - 1999 nT Electric field strength: 1 - 1999 V/m +/- 2 %, +/- 20 digits @ 50/60 Hz E-field sensor for electrical LF- fields H-field sensor for magnetic LF-fields (one-dimensional) acoustic signal proportional to the field strength with "Geiger-counter-effect" RMS 9 Volt Alkaline manganese battery (included), average operation time 24-36 hours

- 21 -

LF-Technology

Low frequency analyser ME3840B

The link between amateur and professional instruments

This device supports all above mentioned "common advantages". It is especially popular among medics and alternative practitioners, as it offers a perfect combination of easy handling and professional measurement possibilities. It allows an easy allocation of the electrosmog frequencies to the traction power or the mains power as well as to the artificial harmonics, thus facilitating an especially precise consultation of remedial actions and an easy control of their effectiveness. Comprises all features of the ME3830B, and additionally offers: A switchable internal filter module as in the professional devices, allowing a numeric differentiation of traction power and mains supply as well as the artificial higher frequencies. A useful aspect considering the even lower precautionary values for higher frequencies.
Scope of delivery: Measurement device, grounding cable, alkaline manganese battery, detailed instructions manual with factual background information Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Power supply: 5 Hz - 100 KHz (compensated, better than -2 dB). Magnetic flux density (unidimensional): 1 - 1999 nT Electric field strength: 1 - 1999 V/m +/- 2 %, +/- 20 digits @ 50/60 Hz E-field sensor for electrical LF- fields H-field sensor for magnetic LF-fields (one-dimensional) acoustic signal proportional to the field strength with "Geiger-counter-effect" RMS 9 Volt Alkaline manganese battery (included), average operation time 24-36 hours Low-Batt. indication, auto-power-off

LF-Technology

Low frequency analyser ME3851A

compact and professional

This device represents the low-cost access to the professional low-frequency measurement technology. Its functions and features are tailored to the needs and practical experiences of the building biology. Comprises all features of the ME3840B, and additionally offers: Responsivity increased by a factor of 10 (minimum display resolution: 0.1 V/m / 0.1 nT). NiMH battery, battery charger / power supply unit included. An AC- and a DC-output. Increased reliability by the use of a test switching mode for the zero deviation. Perfectly suitable also for potential-free measurements with the help of the potential-free mounting for LF measurement devices.
Scope of delivery: Measurement device, highly flexible grounding cable with a copper diameter of 1mm, grounding clamp NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instructions manual, plastic case Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Signal output ports: Power supply: 5 Hz - 100 KHz (compensated, better than -2 dB). Switchable, internal frequeny filter: 16.6 Hz bandpass, 50 Hz highpass, 2 kHz highpass for identification and evaluation of sources of pollution Magnetic flux density (unidimensional): 0.1 - 1999 nT Electric field strength: 0.1 - 1999 V/m +/- 2 %, +/- 7 digits @ 50/60 Hz E-field sensor for electrical LF- fields H-field sensor for magnetic LF-fields (one-dimensional) acoustic signal proportional to the field strength with "Geiger-counter-effect" RMS AC- and DC-output Rechargeable NiMH battery inside the meter, average operation time: 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included

- 22 -

Low frequency analyser ME3951A

compact and professional

With its full TCO bandwidth, this device is predestined for the professional user. Its functions and features are tailored to the needs and practical experience of the building biology. Due to its comparably low price, it is often also used for scientific and industrial purposes. Comprises all features of the ME3851A, and additionally offers: An extended frequency range from 5 Hertz to 400 Kilohertz, in accordance with the TCO guidelines. An important decision criterion when offering professional LF measurements.

Scope of delivery: Measurement device, highly flexible grounding cable with a copper diameter of 1mm, grounding clamp NiMH battery inside the meter, mains adaptor, battery charger, various adaptors, detailed instructions manual, plastic case Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Signal rating: Signal output ports: Power supply: 5 Hz - 400 KHz (compensated, better than -2 dB). Switchable, internal frequency filter: 16.6Hz bandpass, 50 Hz highpass, 2 kHz highpass for the identification and evaluation of sources of pollution Magnetic flux density (unidimensional): 0.1 - 1999 nT Electric field strength: 0.1 - 1999 V/m +/- 2 %, +/- 7 digits @ 50/60 Hz E-field sensor for electrical LF- fields H-field sensor for magnetic LF-fields (one-dimensional) acoustic signal proportional to the field strength with "Geiger-counter-effect" RMS Rechargeable NiMH battery inside the meter, average operation time: 8 hours Low-Batt. indication, auto-power-off AC-adaptor for charging and long-term-operation included AC- and DC-output

How healthy is your sleep? Measurements provide answers!

- 23 -

LF-Technology

GIGAHERTZ SOLUTIONS
Made in Germany

NFA-SERIES
3D NF Analyser with Data Logger
The innovative concept for the field strenght measurement technology within the building biology

The NFA 1000 requires only very few settings and is able to process hundreds of thousands of pieces of information per second in the background, allowing you to capture the most important parameters at one glance in the process of measuring. At the same time, all relevant measurement and instrument data are simultaneously and continuously recorded onto a standard SD memory card, linked with the possibility of dictating audio notes live directly into the device. A minimum of effort will therefore provide a maximum of information for a detailed analysis on your PC later on. This leaves you with more time for the essential task: The best possible consultation of your customer. The PC evaluation software NFA-see included in the scope of supply requires no installation, impressively displays the measuring results, supplies statistical evaluations in real time, and provides all information you need for your measurement protocol in a flash.
- 24 -

The measurement: Less is more!


The NFA only displays the information important for the process of measurement: - A default display indication is the 3D-total pollution.

PC Software within the scope of supply NFAsee: All at one glance !


The innovative PC evaluation software: An in-house product developped specifically for the NFA, opening up all possibilities of the NFA to the user.

- Differently coloured LEDs parallelly show the relevant frequency components and a limit value indication. - Measurement algorithms and audio notes allow for an extremely rational measurement process. - The NFAs indicate and correct absurd settings. This programme permits a detailed view and analysis of the recorded data, backed up also by the integrated audio notes recorded by the NFA during the process of measurement. Further highlights: - supplies statistical evaluations of the selected range in real time - supports the efficient elaboration of informative measurement protocols.

The evaluation: More is more!


- In order to avoid an uncomplete protocol on your PC due to a lack of details, the NFA is able to capture the frequency and axis information simultaneously, continuously, and without blind spots. - The high resolution of 10 data records per second as well as the revolutionary PC evaluation software NFA-see allow for a completely new aspect of the much discussed phenomenon of dirty power.

NFAset: Everything under control !


You can define the standard settings you prefer for your device: Simple Operation or All Details, whichever suits you most. And you can easily control all functions such as the measurement unit or the pre-programming of longterm recordings.

GIGAHERTZ SOLUTIONS
Made in Germany

... patented high-tech ... trend-setting innovations !

Potential-free 3D measurement without the cube - Is that possible?


Yes, indeed, it is - with the help of two patents and a few further ideas, we have managed to literally square the circle: - Standardised active sensor covers compensate the differing sizes of the field plate pairs. - The utilisation of parasitic effects of the sensors helps compensate the shortening effect of the long axis.

- 25 -

NF - Technik

3D-Magnetic field analyser with data logger NFA 30M

for a most in-depth analysis

Allows long-term measurements as required in the standard values for bedrooms (SBM). It is based on a superior concept for efficient data acquisition of magnetic fields, extensive long-term recordings of all relevant parameters and an easier interpretation and documentation of the acquired data. The photo shows the optically identical NFA 1000, as a photo of this device is not yet available. Features: 3D measurement in a truly isotropic point. Separate recording of railway and grid frequency as well as higher harmonics with true RMS valuation (16.6 Hz | 50/60 Hz | 100/120 Hz plus even harmonics | 150/180 Hz plus uneven harmonics | other frequencies < 2 kHz | all > 2 kHz). Measures 110,000 samples per second, the maxima of which are recorded up to 10 times per second on the 4 GB SDHC memory card supplied. Due to the simultaneous and continuous sampling of frequency and axis information you won't miss even the smallest peaks. Voice recording of audio notes to facilitate measurement and interpretation of recordings. Input jack to record an external HF-Analyser. Supplied with revolutionary PC evaluation software: Super fast real-time presentation, statistic functions (e.g. 95. percentile), analysis tool for "Dirty Power". Li-Ion rechargeable batteries for up to 48 hours of continuous recording. External power supply possible (power adaptor included).

LF-Technology

Technical data:
Frequency Range: 16 Hz to 32 KHz (compensated, better than -2 dB).

3D-Magnetic field analyser with data logger NFA 400M

for the most in-depth analysis

Allows long-term measurements as required in the standard values for bedrooms (SBM). It is based on a superior concept for efficient data acquisition of magnetic fields, extensive long-term recordings of all relevant parameters and an easier interpretation and documentation of the acquired data. The photo shows the optically identical NFA 1000, as a photo of this device is not yet available. Comprises all features of the NFA 30M, and additionally offers: Frequency range extended to the full 400 kHz in accordance with the TCO guidelines. This is an important criterion for an in-depth analysis of artificially generated higher harmonics, as for example produced by the so-called "Dirty Power". Broadband peak measurements (genuine peak of a wave) as a firmware update in preparation.
Technical data:
Frequency Range: 5 Hz to 400 KHz (compensated, better than -2 dB).

3D-LF-Analyser with data logger NFA 400

for the most in-depth analysis

Innovative alternative to the ME series based on a superior concept for efficient data acquisition of electric and magnetic fields, extensive long-term recording of all relevant parameters and an easy interpretation and documentation of the acquired data. The photo shows the optically identical NFA 1000, as a photo of this device is not yet available. Comprises all features of the NFA1000, but... ONE-dimensional instead of THREE-dimensional electrical field measurements (Y-axis) and no peak measurements.

Technical data:
Frequency Range: 5 Hz to 400 KHz (compensated, better than -2 dB), even better than the technical specifications required by the TCO standards for workstations.

- 26 -

3D-LF-Analyser with data logger NFA 1000

for the most in-depth analysis - our masterpiece!

Innovative alternative to the ME series based on a superior concept for efficient data acquisition of electric and magnetic fields, extensive long-term recordings of all relevant parameters and facilitated interpretation and documentation of the acquired data. Features: Real 3D potential-free electric field measurement, patent pending. 3D measurement of the magnetic field in a truly isotropic point. Separate recordings of railway and grid frequencies as well as higher harmonics with true RMS valuation (16.6 Hz | 50/60 Hz | 100/120 Hz plus even harmonics | 150/180 Hz plus uneven harmonics | other frequencies < 2 kHz | all > 2kHz) Measures 110,000 samples per second, the maxima of which are recorded up to 10 times per second on the 4 GB SDHC memory card supplied. Due to the simultaneous and continuous sampling of frequency and axis information you won't miss even the smallest peaks. Voice recording of audio notes to facilitate measurement and interpretation of recordings. Broadband peak measurements (genuine peak of a wave) as a firmware update in preparation. Optional, in preparation: Wireless data transfer to external display unit /PC. Supplied with revolutionary PC evaluation software: Super fast real-time presentation, statistic functions (e.g. 95. percentile), analysis tool for "Dirty Power". Li-Ion rechargeable batteries for up to 48 hours of continuous recordings. External power supply possible (power adaptor included).
Technical data:
Frequency Range: 5 Hz to 1000 KHz (compensated, better than -2 dB), also includes modern power adapter radiation, reducible to 400 KHz for TCO measurements

PC Evaluation Software NFAsee

for the NFA series

Allows for an uncomplicated summary of the extensive recordings of your NFA. Revolutionizes the evaluation of individual measurements and long term recordings. Included in the NFA scope of supply. No installation required. Can be run with all systems as from Windows 98, with Linux, and, if required, also with MAC. In combination with the NFA, it offers totally new possibilities of analysis, especially concerning the so-called "dirty power". Easy to operate. Real-time indication of statistic values for the selected range. It is of great support when issuing informative and reliable measuring protocols. Multilingual.

Ask for our EMF - courses !

- 27 -

LF-Technology

TCO-compliant probe for the NFA series TCO3

Simplifies the measurements of E-fields in line with the regulations at locations of difficult access, such as bedroom measurements or low-field electrical installation inspections.

Potential-free telescopic rod 80 cm PM2

Potential free rod 80 cm Made of non conductive material Fits all ME series meters Also available in 160 cm ( PM4/34,75 Euro).

LF-Technology

Potential-free telescopic rod 160 cm PM4s

Accessories

Potential free rod 160 cm. Made of non conductive material. With special connection for the NFA-series.

Magnetostatic probe MS-NFA

Designed to be connected to the NFA series A low-cost possibility to extend the measuring range of your NFA. Features: High-precision one-dimensional measurement of constant magnetic fields. Resolution of only 10 nT (therefore even the smallest geomagnetic anomalies can be identified). Switch to select between absolute and relative measurements. To be connected to the CH4 jack of your NFA, while power is supplied via the earphone jack (no need for batteries). This way, measured values can also be recorded and commented through the integrated voice recorder.

Technical data:
Frequency Range: Measurement Range: Accuracy: Sensor: Audio Analysis: Power supply: 0 Hz 10 nT - 100 T +/- 10% (50% rH, 20C) Hall probe Acoustic signal proportional to the field strength (with "Geiger-counter effect", switchable) via the NFA

- 28 -

Electrostatic probe ES-NFA

Designed to be connected to the NFA series A low-cost possibility to extend the measuring range of your NFA. Features: For a measurement of the electrostatic charging of surfaces. A useful aid when choosing material conducive to the indoor environment, such as carpets, curtains, or others. For a measurement and control of electrostatic chargings in the electronics production sector as well as in the paper, textile and plastics industry. The charging voltage of up to +/- 10,000 Volt is displayed with a resolution of 1 V plus its polarity. Spacers ensure that an exact distance be kept to the object to be measured, and thus enable an easy and precise measurement. The electrostatic induction measurement procedure applied does not need any movable or flexible parts, which in turn allows for a robust instrument of a handy size. Delivery in an antistatic transport case.
Scope of delivery: Probe with connecting cables, manual

Technical data:
Frequency Range: Measurement Range: Accuracy: Audio Analysis: Power supply: 0 Hz 1 - 10.000 V/m +/- 10% (50% rH, 20C) Acoustic signal proportional to the field strength (with "Geiger-counter effect", switchable) via NFA

Including hand electrode and grounding cable. To be used for the measurement of the capacitive body voltage in accordance with the standard guidelines of the building biology measurement technology (SBM). A useful supplement for field strength measurements.

Scope of delivery: Measuring device, set of adapters and plugs, accessories

Silicon holster (protective sheath) yellow HOL1

Protection and professional outfit!

for 3D-LF and HF series colour: yellow (delivery without measuring device)

USB data logger EL-USB3

for HF + LF devices! USB data logger stick for the recording of the DC output of our measuring devices. Easy-to-operate software for a graphical evaluation of the measured values included. DC-voltage data logger. suitable for HF58B, HF58B-r, HF59B, ME3851A, ME3951A and NFA series. To be connected with an optional Gigahertz-produced adapter cable (Logkab1+2 / 38,20 Euro). Logging rate adjustable from 1 s to 12 hours. Memorizes 32,000 measured values,voltage measuring range DC 0 to 30V
Scope of delivery: Data logger, manual, Gigahertz brief instructions, software CD, Lithium battery

- 29 -

Accessories

LF-Technology

Digital multimeter set VC-840 Set

Protective Shielding
A physical problem such as electro smog with all its various specifications can be successfully met with several physical solutions, a selection of which you will find on this page. Our product line does, of course, not include mobile phone chips or any other item without proven physical effect. If you are interested in large surface shielding of complete walls or houses, we recommend to contact an experienced building biologist. In the following please find basic solutions for widespread sources of radiation, which can also be successfully implemented by non-professionals.

- 30 -

Headset AERO_99

phoning mobile at a "safe distance" Mobile phones, but also conventional headsets, especially also their earphones, are known to cause considerable electro smog directly next to the head.The AERO_99 is able to reduce this HF-radiation by 99% (SAR-certificate is available). The earphone is 100% LF-field-free (acoustic connector without electronic loudspeaker). Reduces HF-radiation by 99% The functional principal has proven successful millions of times in the medical technology (stethoscope). Ultralight AirComTM technology for crystal-clear sound propagation and high wearing comfort at the same time. Important: Please ask for adapters for your phone type.
Scope of delivery: Headset AERO_99

Shielding paint 1 litre HSF54-1

protects from high and low frequencies

Shielding paint for interior and exterior shielding against high-frequency radiation (HF) and low-frequency electric fields (LF). Based on a high quality pure-acrylic binder, this shielding paint offers a perfect compromise of excellent shielding attenuation, high water resistance and good ecology. Grounding essential! Please see the ground-connection set. For interior and exterior application Attenuation in a single-layer coat: Up to 40 dB (99.99 % shielding effectiveness). Breathable, low-emission, solvent-free. Durably corrosion resistant, without metal particles. Yield for interior application: 7.5 m/ l, exterior application: 5 m/l. Excellent adhesion on different surfaces in the interior and exterior, e.g. on older coatings, plasterings, concrete, styrofoam, wood, etc. Colour: black. Can easily be overcoated with all kinds of emulsion paints.
Scope of delivery: Paint, manual

Shielding paint 5 litres HSF54-5

protects from high and low frequencies

For interior and exterior application Attenuation in a single-layer coat: Up to 40 dB (99.99 % shielding effectiveness). Breathable, low-emission, solvent-free. Durably corrosion resistant, without metal particles. Yield for interior application: 7.5 m/ l, exterior application: 5 m/l. Excellent adhesion on different surfaces in the interior and exterior, e.g. on older coatings, plasterings, concrete, styrofoam, wood, etc. Colour: black. Can easily be overcoated with all kinds of emulsion paints.
Scope of delivery: Paint, manual

Ground-Connection-Set ES interior ES

Ground-Connection-Set for shielding paints - interior

Each connected area (or surface) requires one Ground-Connection-Set. High-grade steel plate 8 x 8 x 0.3 cm with special conductive fleece on the backside. Earth-connection M6. 4 stainless steel screws, 4 dowels with a of 6 mm. 1 m grounding cable 2.5 mm pre-assembled. Illustrated instruction sheet enclosed. Also available as ground-connection set for an exterior installation.

Scope of delivery: Ground-Connection-Set

- 31 -

Shielding

Shielding paint for interior and exterior shielding against high-frequency radiation (HF) and low-frequency electric fields (LF). Based on a high quality pure-acrylic binder, this shielding paint offers a perfect compromise of excellent shielding attenuation, high water resistance and good ecology. Grounding essential! Please see the ground-connection set.

HF-shielding fabric ST-Naturell

to protect from high frequency radiation!

You can order this product in measures of 0.1 linear meters. Please enter for instance 4.6 in your order! This product is cut off a large roll of fabric according to customer specifications. No return possible! NATURELL is a semi-transparent cotton fabric for the protection against high-frequency (HF) radiation. Perfectly suited as curtain. 100% textile characteristics: Washable, easy sewing and ironing. For questions or special cuts please contact us by email. Price stated per running meter. Width: 250 cm, Length: linear meter. Attenuation 40 dB (99.99 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany. The shielding power is effected by a wrapped silver-plated copper fiber. Material: Ecological cotton fabric, certified to ko-Tex 100 and 1000. Colour: white. Cannot be grounded. If you wish to order individually tailor-made curtains, please contact us by mail or phone. These orders are subject to an extra charge of 10 per curtain incl. lead weights.

HF-Shielding fabric ST-New-Daylite

to protect from high frequency radiation! Especially translucid and permeable to air!

You can order this product in measures of 0.1 linear meters. Please enter for instance 4.6 in your order! This product is cut off a large roll of fabric according to customer specifications. No return possible! NEW-DAYLITE is a highly-transparent polyester fabric (Trevira) for the protection against high frequency (HF) radiation. Perfectly suited as curtain. 100 % textile characteristics: Washable, easy sewing and ironing. For questions and special cuts please contact us by email. Price stated per running meter. Width: 260 cm, Length: linear meter (price per linear meter). Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich.The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, Colour: white. Cannot be grounded. If you wish to order individually tailor-made curtains, please contact us by mail or phone. These orders are subject to an extra charge of 10 per curtain incl. lead weights.

Shielding

HF-Shielding fabric ST-New-Topas

to protect from high frequency radiation! Meets high fire protection requirements.

You can order this product in measures of 0.1 linear meters. Please enter for instance 4.6 in your order! This product is cut off a large roll of fabric according to customer specifications. No return possible! NEW-TOPAS is a semi-transparent polyester fabric (Trevira CS) for the protection against high frequency (HF) radiation. Perfectly suited as curtain. 100% textile characteristics: Washable, easy sewing and ironing. Meets fire protection standard B1 for public buildings! For questions and special cuts please contact us by email. Price stated per running meter Width: 250 cm, Length: linear meter. Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany. The shielding power is effected by a wrapped silver-plated polyamid fiber. Material: Trevira CS, meets fire protection standard B1 for public buildings! Weight: 39 g/m, colour: white. Grounding: Cannot be grounded. If you wish to order individually tailor-made curtains, please contact us by mail or phone. These orders are subject to an extra charge of 10 per curtain incl. lead weights.

- 32 -

HF- king-size bed canopy NEW-DAYLITE CDD25 BD-DO

uncomplicated and effective! Extremely spacious.

NEW-DAYLITE is a highly-transparent polyester fabric (Trevira) for the protection against high frequency radiation (HF). This shielding canopy provides a simple and low-priced method for a complete shielding of beds. Width: 230 cm, depth: 230 cm, height: 240 cm. Appearance: Box-shaped. Entry: Easy entry through two overlapping openings. Mounting: By 4 points on the ceiling. The canopy installation can be stabilized by inserting bars of any kind (not included in delivery) into the sewed hangers. Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany.The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, colour: white Grounding: Cannot be grounded.
Scope of delivery: Canopy, mounting material (plugs, hooks, snap hooks, cord).

HF-single bed canopy NEW-DAYLITE CSD25 BD-EN

uncomplicated and effective! Extremely spacious.

NEW-DAYLITE is a highly-transparent polyester fabric (Trevira) for the protection against high frequency radiation (HF). This shielding canopy provides a simple and low-priced method for a complete shielding of beds. Width: 130 cm, depth: 230 cm, height: 240 cm. Form: Box-shaped, easy entry through one overlapping opening. Mounting: By 4 points on the ceiling. The canopy installation can be stabilized by inserting bars of any kind (not included in delivery) into the sewed hangers. Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany.The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, colour: white. Grounding: Cannot be grounded.
Scope of delivery: Canopy, mounting material (plugs, hooks, snap hooks, cord).

HF-universal bed canopy made of NEW-DAYLITE CUD25 BD-UN

uncomplicated and effective!

NEW-DAYLITE is a highly-transparent polyester fabric (Trevira) for the protection against high-frequency radiation (HF). This shielding canopy provides a simple and low-priced method for a complete shielding of beds. Low priced, but not as spacious as the box-shape canopy due to its pyramidal shape! In our opinion only recommendable when a fast buildup or a cheap shielding solution is required. Bottom width: 300 cm, bottom depth: 300 cm, height: 240 cm. Form: pyramidal, with a 60 cm ring to increase top width, easy entry through overlapping opening. Mounting: by one point on the ceiling. Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany. The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, colour: white. Grounding: Cannot be grounded.
Scope of delivery: Canopy, mounting material (plugs, hooks, snap hooks, cord).

- 33 -

Shielding

HF-floor mat "small" NEW-DAYLITE CND25 BD-ULK

shielding mat for underneath the bed - closes the Faraday cage

We also recommend shielding the canopy from below, to achieve a complete Faraday cage. This floor mat is a sewed piece of shielding fabric that can be laid under the bed or under a carpet. Deep-pile fabrics, by default, are not supplied with lining, to both keep costs down and avoid any incompatibility with your interior design. Appropriate for our single-bed canopy. Width: 150 cm, depth: 250 cm Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany.The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, color: white. Grounding: Cannot be grounded.

HF-floor mat "big" NEW-DAYLITE CMD25 BD-ULG

shielding mat for underneath the bed - closes the Faraday cage

We also recommend shielding the bed canopy from below, to achieve a complete Faraday cage. This floor mat is a sewed piece of shielding fabric that can be laid under the bed or under a carpet. Deep-pile fabrics, by default, are not supplied with lining, to both keep costs down and avoid any incompatibility with your interior design. Appropriate for our kingsize-bed and single-bed canopy. Width: 250 cm, depth: 250 cm. Attenuation 25 dB (99.7 % shielding effectiveness) at 1 GHz. Attenuation certified by Prof. Dipl.-Ing. P. Pauli of the University of the German Federal Armed Forces in Munich, Germany. The shielding power is effected by a wrapped silver-plated copper fiber. Material: Trevira, colour: white. Grounding: Cannot be grounded.

Shielded cable, sold by the metre KAB-LM

reliably shields electrical fields

Shielding

Installation in accordance with VDE 0298, part 3: On-wall or in-wall mounting in dry, humid or wet rooms, as well as in the bricking and in the concrete, except for direct embedding in no-fines concrete, jolted, or compressed concrete. Also suitable for outside mounting as long as protected against direct sunlight, however not in the soil. Primarily adequate for laboratories, clinics, technical studios, biological buildings and computer technology. High protection against interfering radiation from electrical fields penetrating from outside, as well as shielding of the fields caused at the wires. Price per meter NYMST-J 3x1,5 mm house installation cable Shielded Outside diametre approx. 9 mm PVC

4-fold shielded multiple socket outlet SLS4000

with VDE certificate

Minimises the electromagnetic radiation caused by the mains current (ideal, for example, for computer workstations) Industrial quality Shielded casing. Flexible PVC hose line, shielded and twisted (length approx. 2.2 m, 3 x 1.5 mm). With HF-interference suppression filter for the attenuation of supply voltage peaks ("dirty power"). Falls below the limit values set by the TCO guidelines. Includes VDE certificate, child safety lock and double-pole switch. Capacity: 250 VAC / max. 16A / 3500 W. Solid aluminium profile with 4 Schuko socket elements (45). Take-up options at both ends.
Scope of delivery: Multiple outlet strip

- 34 -

Shielded low-heat-device connecting cables KAS-0006

offers continuous protection

Minimizes electromagnetic pollution from computer connecting cables, monitors, printers, and other flexible devices. Flexible PVC hose cable with VDE certificate, shielded and twisted. Coated right-angle Schuko plug and low-heat-device socket, coated. Safety values below those determined in the TCO guidelines. 250 VAC / resistant to max. 10A

Scope of delivery: Connecting cable for low-heat-devices

Shielded laptop connecting cable KAS-0007

offers continuous protection

Minimizes electromagnetic pollution from computer connecting cables, monitors, printers, and other flexible devices. Flexible PVC hose cable with VDE certificate, shielded and twisted. Right-angle Schuko plug and C5 socket, black. Safety values below those determined in the TCO guidelines. 250 VAC / resistant to max. 10A

Scope of delivery: Connecting cable

Shielded extension lead KAS-0008

offers continuous protection

Minimizes electromagnetic pollution from flexible leads and devices. Flexible PVC hose cable with VDE certificate, shielded and twisted. Schuko socket and plug, white, 5m. Safety values below those determined in the TCO guidelines. 250 VAC / resistant to max. 10A

Scope of delivery: Extension lead

- 35 -

Shielding

Demand Switches
For the first time ever, the VDE-mark for approved and certified security (VDE = German Association of Electrical, Electronic and Information Technologies) has been awarded for the demand switches of our NA-comfort series. The devices are additionally equipped with a patented energy-saving circuitry.

Compared to conventional demand switches, the NA7 has the following advantages: Easy installation without complicated adjustments to the local situation or installation of additional base load elements. It reliably works also with electronic consumers (such as rotating dimmers, vacuum cleaners, switching power supplies for instance for halogen ceiling lights) The controlled direct voltage and a cascaded rectifier circuit forces the critical residual ripple down to only few millivolts. The system control lamp which comes with the device allows an easy and constant function monitoring. It also serves as excellent lightning protector in the case of excessive voltage due to a lightning strike in your neighbourhood. Reverse polarity protection: If phase and neutral are accidentally wired the wrong way, this will be signalised and so protect you from installation errors. Resumes functionality autonomously after an electric power outage. Minimum turn-on delays and short turn-off delays, without risking instable switching status

Gigahertz Demand Switches: industrial production made in Germany

- 36 -

Demand switch Comfort 1 C1

the best-price device of its type Even the basic model is already equipped with the most important innovations of the comfort-series. Reliable operation, also with dimmers, fluorescent lamps and energy-saving lamps, halogen spot lights and devices with electronic start-ups, such as vacuum cleaners. Navigation lights within the light switches and night lights still work also when the circuit is disconnected. Protected against reverse polarity and excess voltage. An LED display indicates circuit disconnection.
Scope of delivery: Demand switch, system control lamp, detailed instructions manual

Technical data:
Effective power: Nominal voltage / capacity: 10 A, 230 VAC +/- 10%, 2300 watt bulb load. Mechanical operating time of relay: approx. 15,000,000 switching cycles. Single-pole disconnection: for optimum operator protection and minimum residual ripple. A low resistance outlet will allow optimal channeling in the case of overcouplings. < 8 mV / < 16 mV / < 32 mV (nominal/typical/maximum) Surveillance voltage: DC voltage (230 VDC, max. 8 mA or 1.8 watt load) uncritical with regard to the building biology standards.

Ripple:

Demand switch NA5 comfort with VDE mark NA5

the low-priced 16A-type with VDE certificate

Disconnects voltage directly in the fuse box as long as no electricity is needed. In addition to all functions of the NA1, it offers: Higher capacity: Pre-fuse 16 A Lower residual ripple: < 8 mV

Scope of delivery: Demand switch, control lamp, detailed instructions manual Technical data:
Effective power: Nominal voltage / capacity: 16 A, 230 VAC +/- 10%, 2300 watt bulb load. Mechanical operating time of relay: approx. 15,000,000 switching cycles. Single-pole disconnection: for optimum operator protection and minimum residual ripple. A low resistance outlet will allow optimal channeling in the case of overcouplings. < 4 mV / < 8 mV / < 16 mV (nominal/typical/maximum) Surveillance voltage: DC voltage (230 VDC, max. 8 mA) uncritical with regard to the building biology standards.

Ripple:

Demand switch NA7 comfort with VDE mark NA7

Our top-selling demand switch with VDE Mark

Disconnects voltage directly in the fuse box as long as no electricity is needed. In addition to all functions of the NA5 it offers: Even lower residual ripple: < 4 mV. LED-supported function diagnose for even easier installation and operation. The TOPSELLER among the demand switches!

Scope of delivery: Demand switch, control lamp, detailed instructions manual Technical data:
Effective power: Nominal voltage / capacity: 16 A, 230 VAC +/- 10%, 2300 watt bulb load. Mechanical operating time of relay: approx. 15,000,000 switching cycles. Single-pole disconnection: for optimum operator protection and minimum residual ripple. A low resistance outlet will allow optimal channeling in the case of overcouplings. < 2 mV / < 4 mV / < 8 mV (nominal/typical/maximum) Surveillance voltage: DC voltage (230 VDC, max. 8 mA) uncritical with regard to the building biology standards.

Ripple:

- 37 -

Demand Switches

Demand switch U8

also for the disconnection of stand-by devices Disconnects voltage directly in the fuse box as long as no electricity is needed. A patented coupling also allows for a reliable disconnection of the so-called "primary side supply units". The apparent output which can be disconnected is up to 100 watt. Ideal, for instance, for the control of roller shutters which cannot be disconnected with the conventional demand switches. Surveillance voltage only 230 Millivolt - the lowest value on the market. The different setting opitons render a lot possible, but also require a little more installation and mind effort.
Scope of delivery: demand switch, control lamp, base load element, detailed instructions manual

Technical data:
Effective power: Ripple: Nominal voltage / capacity: 16 A, 230 VAC +/- 10%, 2300 watt bulb load. Mechanical operating time of relay: approx. 15,000,000 switching cycles. Single-pole disconnection: for optimum operator protection, minimum residual ripple, and an active HF-NF-compensation. < 1 mV / < 1 mV / < 1 mV (nominal/typical/maximum) Surveillance voltage: Minimum DC-voltage (230 Millivolt)

Installation example of a demand switch:

Consumer / Lamp Fuses Demand switches

interruptor House service connection diferencial

Monitoring circuit voltage NA1-8 + C1-8series: 250 V DC Ultima series: 0.23 V DC

Demand Switches

- 38 -

For a healthy and restful sleep...


Automatic disconnection of the electric fields with the Gigahertz demand switches.

Childrens bedroom

Bedroom

Fuse box

- after switching off the last consumer the demand switches automatically take the mains voltage off the lines - one demand switch needed per electric system, e.g. one for the bedroom and one for the childrens room - simple installation into the fuse box by your local electrician

- 39 -

Demand switches

Technical Annex / Tables

Youre welcome to also inform yourself online under

www.gigahertz-solutions.com
You will find a great deal of background information on electromagnetic pollution and on our courses, as well as plenty of audio-visual material!

- 40 -

Demand Switches and Accessories


Technical data, range of functions & features

Type

Demand switch NA 1 to 8 comfort with VDE certificate NA1 comfort with VDE 10 < 16 NA5 comfort with VDE 16 <8 NA7 comfort with VDE * 16 <4 NA8 comfort with VDE 16 <4
Demand switch comfort 1 to 8 (predecessor of the NA 1 to 8 with VDE certificate) comfort 1 10 < 16 comfort 5 16 <8 comfort 7 * 16 <4 comfort 8 16 <4

* the most popular type of the whole range

Demand switch ultima (especially made for electric systems with standby devices) ultima 8 * 16 <1 ultima 8 time (also for 16 <1
refrigerators and water beds)

* the most popular type of its series

100 W 100 W
* the most popular type of its series

Mains disconnection relays for special installation situations NEFA 16-plus S16 narrow line, for common installation situations NEFA 16-plus 2P16 for two-phase circuits (e.g. in Belgium, partly in Spain and Italy) NEFA 16-plus F/1 Manual remote switching only ("for extreme cases")
The NEFA 16-plus S and -2P require base load elements to switch off electronic devices. Details upon request

Demand switches accessories System control lamp ultima (additional; one lamp is included in the scope of supply) System control lamp comfort (additional; one lamp is included in the scope of supply) Base load element (for the ultima-series; one piece included in the scope of supply) Wall mounting cases Socket outlet adapter (without demand switch!) Demo-Set "Disconnecting/Shielding/Field characteristics" (for instance for lectures)
(The demo set consists of one NA7 comfort integrated in a table housing with shielded cables, Schuko socket and halogen table lamp)

Decision aid: Which type for which application?


The patented circuit technology guarantees high functionality and switching stability as well as best building biology results in the competitive comparison. High quality components and processing - reliable devices. NA 1 to 8 comfort. The first with VDE certificate for certified device safety. Simple installation, as no adjustment required. Reliable operation also with electronic consumers. New power saving circuit. comfort 1 to 8: Like all common bargain offers w i t h o u t VDE certificate, but already w i t h the unreached basic advantages of the new NA comfort series certified by the VDE. ultima: The only demand switch capable of automatically disconnecting circuits with stand-by devices (shutter controls, charging devices, etc.) Manual adjustment and, if necessary, base load elements (1 incl. in scope of supply) required for critical consumers. Mains disconnection relay: Especially worth mentioning is the remote mains disconnection relay: The manual disconnection by hand-held transmitter allows for the reliable disconnection of also critical consumers, such as telephones, faxes, alarm systems

- 41 -

Demand Switches - Product Chart and Prices

within the scope of supply Manual connection of mains voltage possible

System control lamp

Manual adjustment possible/required

Nominal switching capacity (Amp. at 250 V AC)

(in

Residual current indication for function diagnose

Apparent power disconnectable

Ripple (typ.) Millivolt)

M / E Analyser for the low frequency


Basic Analysis LF Analysers Frequency ranges Frequency range (from ... to) Filter module 16.7 Hz / 50Hz / 2kHz Measuring range Measuring range 1 - 2000 nT / Vm Measuring range 0.1 - 200 nT / Vm Sensors Internal 1D magnetic field sensor Internal sensors bound to earth potential in Y-direction Internal potential-free 1D-E-field sensor in Y-direction (increased tolerance) TCO-compliant E-field sensor "TCO Light" (mountable) Features AC and DC outputs Auto power-off Scope of supply and optional accessories 9 V battery NiMH rechargeable battery Power supply unit Certificate of calibration with frequency run " KAL-NF" External dislpay DP3000A Grounding cable Grounding clamp Potential-free telescopic rod Plastic transport case
16 Hz 2 kHz 16Hz 100 kHz 5 Hz 100 kHz ME3030 ME3830

ME Series

Made in Germany

Professional Analysis
ME3840 ME3851 ME3951

5 Hz 100 kHz

5 Hz 400 kHz
opt.


opt.


incl.

incl.

incl.

incl. incl. opt. opt. incl. opt. opt. opt. incl. opt. opt. opt. incl. opt. opt. opt. incl. incl. opt. incl.

incl. incl. opt. opt. incl. incl. opt. incl.

- 42 -

NFA Series
3D LF analysers with data logger
3D LF analysers Frequency ranges Frequency range (from ... to) Frequency selective filter 16.6 | 50/60 | 100/120 | 150/180 | Rest < 2kHz | >2kHz Magnetic flux density Measuring range "M" in Nanotesla (alternatively displayed in Milligauss)
Internal 3D sensor (isotropic point < 3cm ) (pat. pend.)
3

M a d e in G e r m a n y

NFA 30M

NFA 400

NFA 1000

16 Hz 32 kHz

5 Hz 400 kHz

5 Hz 1MHz

1 - 19999 nT (up to 400 T upon request)

Electric field strength Measurement range in Volt per meter (V/m) Optional range extension upon request Internal potential-free 3D-E-field sensor (Patent DE 10 2007 025 911) Internal potential-free 1D-E-field sensor in Y-direction Internal sensor bound to earth potential in Y-direction (TCO Recommendation) Input for the measurement of capacitive body coupling acc. to SBM (hand electrode opt.) Optional sensors ("CH 4") TCO compliant E-field sensor (diameter 30 cm, mountable) Magnetostatic sensor Electrostatic sensor Input for AC or DC signals (for instance for the connection of an HF analyser) Signal analysis True RMS True RMS hold / Peak hold Peak value, broad band (true peak of the wave) Display features Large LC display (4 digits), also easy to read from afar Frequency indication by differently coloured LEDs or by numerical value Acoustic signal (Geiger-counter-effect, volume adjustable) Internal data logger
Sampling rate: 110,000 samples/sec., maxima are saved up to 10 times/sec onto the SDHC card. Simultaneous and frequency selective for XYZ and CH4, i.e. without "blind spots".

0.1 to 1,999 V/m

1 - 19,990 mV

opt. opt. opt.

opt. opt. opt.

Voice recorder Configuration and evaluation software for PC: Innovative graphical and statistical functions, frequency- and axis-specific Instrument "lockable" to assure safe recordings in the case of unauthorised access Scope of supply and optional accessories Internal Li-Ion battery pack (for up to 48 h "full speed"-recordings, NFA 30M more than 48h) AC-adaptor for quick loading or for mains supply (unlimited recordings possible in this case) Terminal nut for the stand integrated at the bottom of the housing Grounding cable Floating potential telescopic rod (PM4s) or instrument holder (PM1) Compact plastic transport case K5

opt.

opt.

Rev. 4.0 as of February 2011, subject to change without prior notice

High Frequency Analysers


Accessories

27 MHz to 10 GHz
Basic Analysis
HF32D HF35C HF38B HFE35C HFW35C
199,50 299,50 499,50 749,40 392,70 167,65 251,68 419,75 629,75 330,00 849,00 713,45 994,60 835,80

Professional Analysis
HF58B HF58B-r HF59B HFE59B HFW59B
1.166,20 1.844,50 1.166,20 980,00 1.550,00 980,00

price incl. VAT

HF Analysers

List price incl. 19% VAT List price net (excl. 19% VAT)

Frequency range (basic device incl. antenna) 800 MHz - 2.5 GHz 800 MHz - 3.3 GHz (2.5 - 3.3 GHz with increased tolerance) 27 MHz - 2.5 GHz (HFE35C), 27 MHz - 3.3 GHz (HFE59B) 2.4 - 6 GHz (e.g. WLAN, WiMAX) 2.4 - 10 GHz (e.g. WLAN, WiMAX, radar) Measuring ranges
Recommended value for sleeping places ("no abnomality") according to SBM08: 0.1 W/m 58.55 99.6 149,70 149,70

10 - 19,990 W/m 1 - 1,999 W/m

(1)

opt.

opt.

opt. opt. opt. opt. opt. opt. opt. opt. opt. opt. +/-4.5dB +/-4.5dB +/- 5 +/- 5 opt. opt. opt. +/-3dB +/- 5

0.1 - 199.9 W/m (1) 0.01 - 19.99 W/m Attenuator DG20 (adapter for 100 x stronger radiation) Attenuator DG20_G10 (like DG20 with improved frequency linearity and DC feedthrough) Preamplifier HV10_27G3 (adapter for 10 x lower radiation) Preamplifier HV20_2400G10 (adapter for 100 x lower radiation) Accuracy Basic accuracy incl. linearity tolerance (incl. antenna tolerance; UBB27 allows increased tolerance below 100 MHz ) Zero deviation (in digits, always only concerning the last digit)

opt. +/-3dB +/- 5

opt. opt. opt. +/-3dB +/- 5

+/-6dB +/-6dB +/-6dB +/-6dB +/-6dB +/- 9 +/- 9 +/- 7 +/- 9 +/- 9

Antenna, logarithmc-periodic within the scope of supply. Several patents granted or pending. Improved resistance against ground influence, minimum deviation, from HF58B upwards with LED control Compensated antenna (HFW: 2.4 GHz high pass filter integrated) 89.25 Direction-finding antenna LAT10 with very narrow directional pattern up to 1.9 GHz (n o t suitable for quantitative measurements)
445,00

opt.

opt.

opt.

opt.

opt.

opt.

opt. opt.

opt.

UBB27_G3: active, quasi-isotropic ultra broad bandwidth antenna from 27 MHz to 3.3 GHz (no log-per.)

LC display: 3.5 digits in W/m

Features for acoustic analysis Sound signal proportional to the field strength (Piezo buzzer) Sound signal proportional to the frequency for an acoustic analysis of pulsed radiation (i.e.: amplitude modulation radiation) (40 mm membrane loudspeaker) Volume regulation for loudspeaker / earphones HFEW35C set consisting of HFE35C andHFW35C HFW59B in planning stage

(1) In combination witht he new NFA-series, a display in V/m is also possible

High Frequency Analysers


Accessories

27 MHz to 10 GHz
Basic Analysis
HF32D HF35C HF38B HFE35C HFW35C
199,50 299,50 499,50 749,40 392,70 167,65 251,68 419,75 629,75 330,00 849,00 713,45 994,60 835,80

Professional Analysis
HF58B HF58B-r HF59B HFE59B HFW59B
1.166,20 1.844,50 1.166,20 980,00 1.550,00 980,00

price incl. VAT

HF Analysers

List price incl. 19% VAT List price net (excl. 19% VAT)

LC display of the overall signal (Patent No. DE 103 17 805) Peak value (Patent No. DE 10334886) Average value (Patent No. DE19809784) Peak hold

Digital display of the pulsed singals only (i.e. of the amplitude modulated part; additional tolerance) Average value / peak value / peak hold (same as for the overall signal, switchable)

Video bandwidth 2 MHz (radar/UMTS-module-optimisation), switchable*

* in this setting there will be higher background noise in the finest measurement range inherent in the system

Frequency filter for frequency selective analysis within a specified frequency range (to be mounted externally)
595,00 125,00

Service specific filter FF6E (switchable: GSM900, GSM1800, DECT, UMTS, WLAN, HP1100, TP1100, TETRA-BOS, DVB-T) rec. rec.

rec. rec.

Steep sided high pass filter HP800_G3 for an improved suppression of the frequencies below 800 MHz

Signal outputs DC output for longterm recordings Audio output (moduliated AC signal) for PC (sound card) / earphones / spectrum analyser Additional standardised AC output (mod. Signal) for NFA series

Power supply (battery included in scope of supply) 9 Volt Alkali Manganese E-block battery spare part price 9-Volt NiMH high quality battery pack (easy replacement by user himself) Power supply unit (for charging of the internal battery or for external power supply) Antenna input for remote power supply (e.g. for active antenna and filter, as well as amplifiers, equalizers, etc.) Average life expectancy per battery / battery pack (almost half when using UBB27)
33.8

10-12h

6-7h

6-7h

6-7h

6-7h

7-8h

7-8h

7-8h

7-8h

7-8h

25,70 43,20 79,85

Transport cases Plastic case K5 ( approx. 27 x 18 x 8 cm ) with foam filler Plastic case K2 ( approx. 33 x 27 x 16 cm ) with formed foam filler (fits two devices with antenna) Aluminium case K3 (surface brushed aluminium; approx. 52 x 40 x 21 cm) with flexible compartments

opt. opt.

opt. opt. opt. = optional opt. opt. opt.

opt. opt. opt. opt. rec. = recommended poss. = possible opt. opt. opt. opt. opt. opt. HFW59B in planning stage

Last update: April 14, 2010

Gigahertz Solutions GmbH, Am Galgenberg 12, D-90579 Langenzenn, Tel. +49 (0)9101 9093-0, Fax +49 (0)9101 9093-23, internet: www.gigahertz-solutions.de, e-mail: info@gigahertz-solutions.de

Small Accessories
Cable Logkab01, connecting cable for EL-USB data logger with ME3851/3951, HF58B/B-r Logkab02, connecting cable for EL-USB data logger with HF59 KAB0048 connecting cable for an HF device to the NFA series (2.5mm jack/jack) Shielding N-80, demo version of shielding material Naturell 80cmx80cm KF-2 retractable ferrites for the reduction of HF on cables (such as Aero_99) ADA-NOK adapter for Nokia pop-port telephones ADA-SAM adapter for various Samsung telephones ADA-MOT adapter for various Motorola telephones ADA-SON adapter for various SonyEricsson telephones Nokia AV, Aero retrofit for NOKIA AV connection TAE2 TAE telephone insert (e.g. 2 telephone on one line) Demand Switches SK1 system control lamp for NA series SK2 system control lamp for Ultima series X21 external line filter 1F GL base load element Accessories / Spare parts DP3000 external display MFP multi function tester MP-1 3D-compass BAT0001 8.4V/200mAh Ni-MH battery for ME/ETC/EMT BAT0007 9.6V/750mAh Ni-MH battery pack for HF5xxx BAT0010 3.7V/2200mAh Li-Ionen battery for NFA series

- 46 -

- 47 -

Measurement technology and high frequency engineering: Research. Development. Industrial Production.

GIGAHERTZ SOLUTIONS
Made in Germany

GIGAHERTZ SOLUTIONS GmbH Managers: Niels Dernedde and Thomas Lorenz Am Galgenberg 12 D-90579 Langenzenn Tel +49-9101-9093-0 Fax +49-9101-9093-23 info@gigahertz-solutions.de http://www.gigahertz-solutions.com

Copyright by Gigahertz Solutions GmbH, Errors and omissions excepted. The standard terms and conditions for delivery and service of the ZVEI e.V. apply.

You might also like