Table of Contents 1. Corrections .....................................................................................................................................3 1.1 1372CNESPE07 BER&FER degradation after EMR activation (1-296629792) ..................3 1.2 14930CNESPE01 UltraSite transmits in None Shutdown after Abis break (16481ESPE01) .................................................................................................................................3 1.3 14931CNESPE01 Non BCCH TRXs stuck after recovery from Shutdown state (7758ESPE07.....................................................................................................................................3 1.4 14932CNESPE01 UltraSite comes up in wrong state after loss of LMU synchronisation (7729ESPE07...........................................................................................................3 1.5 25212CNESPE05 Change to Alarm Handling Specification for alarms when the OMU is blocked ..................................................................................................................................4 1.6 25213CNESPE05 support 'WBC solution for same band co-siting with WCDMA' in HW Configurator.................................................................................................................................4 2. New / Changed functionality...........................................................................................................5 2.1 25211CNESPE05 Addition of Windows Vista Feature to CX6 CD1.0..................................5 3. 3rd party corrections.......................................................................................................................5 4. Previous deliveries for the release .................................................................................................6 5. Appendices / References ...............................................................................................................6 Contact
Contact your local Nokia Siemens Networks support

Summary of changes
01-11-2008 1.0 First Version

DN0821846 Nokia Siemens Networks

2 (7)

Purpose
The purpose of this document is to give a brief summary on this CX6.0 CD1.0 Software Change Delivery (CD) content.

1. CORRECTIONS 1.1 1372CNESPE07 BER&FER degradation after EMR activation (1296629792)


Original problem: When EMR feature is activated, an increase in FER and BER is observed in some sites. The FER and BER degradation affects UL RX Quality measurements and therefore the number of reports in quality bands 4-7 will increase Description of the correction: State machine is changed to speech state only when onset is decoded by the BTS. The original design was that it was changed to speech state when both speech and onset were decoded by BTS.

1.2 14930CNESPE01 UltraSite transmits in None Shutdown after Abis break (7840ESPE07)
Original problem: Site is in shutdown mode following a mains failure, if a short Abis break occurs then following recovery from that Abis break the BCCH will start transmitting again until the NTIM and BTIM timers have expired again. Description of the correction: An additional check has been added so that when the LAPD links are recovering there is a check to determine if the TRX is currently in a shutdown state.

1.3 14931CNESPE01 Non BCCH TRXs stuck after recovery from Shutdown state (7758ESPE07
Original problem: The Block/Unblock of the BCCH TRX when the BTS is in non-BCCH shutdown mode cause the non-BCCH TRX which are in shutdown state at the time not to recover to supervisory state when they are taken out of shutdown state. Description of the correction: An additional check has been added when setting a TRX to blocked user so that it will not be possible if the BTS is in intelligent shutdown state.

1.4 14932CNESPE01 UltraSite comes up in wrong state after loss of LMU synchronisation (7729ESPE07
Original problem: UltraSite can come up in incorrect working state after loss of synchronisation from the LMU. Then when BCF reset is selected there are misleading message shown to user. Description of the correction: The misleading warning shown at BTS Manager is corrected.

DN0821846 Nokia Siemens Networks

3 (7)

1.5 25212CNESPE05 Change to Alarm Handling Specification for alarms when the OMU is blocked
Reason for the Change Note: As per alarm handling specs concerning the alarm Fault in VSWR antenna monitoring it reads that this alarm will be reported on BTS Manager when OMU link is in blocked state. The same incorrect information is also present in the Trouble Management Document provided to customers. Description of the correction: Alarm handling specification and the Trouble Management Document are amended

1.6 25213CNESPE05 support 'WBC solution for same band co-siting with WCDMA' in HW Configurator
Reason for the Change Note: Existing BTS HW Configurator support for XML feature allows the opening/saving of HW Configuration files in XML format (file extension .ewb). The implementation of same band co-siting support in an earlier CX5 release means that when the changes are merged a change in the XML format is required. Description of the correction: A new parameter is added to the CABINET_INFO managed class object to save MRC supported with WBC information in the MMI-EW XML Interface

DN0821846 Nokia Siemens Networks

4 (7)

2. NEW / CHANGED FUNCTIONALITY 2.1 25211CNESPE05 Addition of Windows Vista Feature to CX6 CD1.0
Hardware Configurator and BTS Manager in both Local and Remote connection now support 32 bit Windows Vista Business Edition when used with GCS version R6.0.

3. 3RD PARTY CORRECTIONS


None

DN0821846 Nokia Siemens Networks

5 (7)

4. PREVIOUS DELIVERIES FOR THE RELEASE

CX6.0 Release

CX6.0 CD.1.0

28/02/2007
Release Date BTS Software Products

01/11/2008

BTS_C800.738 06.00-00
BTS Software A5/0

BTS_C800.924 06.01-00 BTS_C800.925 06.01-01 BTS Manager CX6 CD1 (6.0.23)

BTS_C800.739 06.00-01
BTS Software A5/1

BTS Manager 6
BTS Manager Application

Related Products

5. APPENDICES / REFERENCES
None

DN0821846 Nokia Siemens Networks

6 (7)

Disclaimer The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given as is and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright Nokia Siemens Networks 2008. All rights reserved.

DN0821846 Nokia Siemens Networks

7 (7)

You might also like