PASOLINK NEO PASOLINK NEO/c Maintenance

Xian/GuiLin NEC Aug. 2008


NEC-MIC-0807506 Ver.2.1

Course target
Target Audience The program is intended for staffs to operating and maintaining NEC NEO&NEO/c Microwave Equipment Prerequisites Having at least one year experience in installing and testing of RF equipment Being familiar with Windows operation system;Having the basic knowledge of telecommunications Objectives On completion of this program, the participants will be able to: Describe the structure of the NEC NEO, direct or carry our Routine maintenance and troubleshooting for NEC Pasolink MW

2 NEC-MIC-0807506 Ver.2.1

Maintenance Test sets Accessories preparation


No
1 2 3 4 5 6 7 8

Model type
SDH analyzer Optical Variable attenuator Digital meter Bit error meter Screwdriver T type hexagonal driver Torque wrench PC for LCT Terminal

Model number
Mp1570A MN95D -

Manufacture
ANRITSU ANRITSU -

Note: - mean Customer can prepare the tool by themselves, No special requesting about the model number & manufacture
3 NEC-MIC-0807506 Ver.2.1

Maintenance Tasks
The problems existing during installation: 1, Prompt problem due to poor installation or setting mistakes This problem will find out immediately and fix after installation. For instance: IF cable opening, circuit shorting; wrong CH setting 2, Potential problems due to poor installation or setting mistakes This problem remains on your system and not easy be find out. For instance: poor antenna fix, poor grounding system; wrong E1 impedance setting.
Most of installation and manufacture problems will happen within one annual year operation. After that system goes into normal operation period.

4 NEC-MIC-0807506 Ver.2.1

Maintenance Equipment
NEO
NEO /c (NEO PDH sample version)
SAME with NEO
239(W)x247(H)x68(D)mm

O D U I D U

237(W)x237(H)x101(D)mm

482(W)x44(H)x240(D)mm

482(W)x44(H)x190(D)mm 1+0 482(W)x44(H)x230(D)mm 1+1

5 NEC-MIC-0807506 Ver.2.1

Maintenance Tasks
Two Maintenance Tasks in ordinary work 1. Routine Maintenance:
Through routine activity to avoid links problems happen.

2. Troubleshooting:
When problem has happen, or equipment fault, Fix problem, Recover links service.

6 NEC-MIC-0807506 Ver.2.1

1. Routine Maintenance
Meter reading Reading the RSL metering test result and check the link status. Link performance monitoring Check the link performance, 15min and 1 day history monitoring data record can help to analysis the link performance.

7 NEC-MIC-0807506 Ver.2.1

1. Routine Maintenance
Routine maintenance need use NMS by software PNMSJ (remote checking) or PNMTJ (local checking).
Remote access by PNMSJ
Upper NMS

Local access by PNMTJ

admin

Remote Client Access


Filtered Traps

demo

Managed Digital Radio Network

8 NEC-MIC-0807506 Ver.2.1

Routine Maintenance
Metering reading (PNMTJ>performance monitor>meter)

TX power checking the Specification +/- 1dBm RX level according by LOSS design +/3dBm

ODU power supply follow by IDU power 9 NEC-MIC-0807506 Ver.2.1

Routine Maintenance
Metering reading on ODU

Note: lower batter will affect your reading!


10 NEC-MIC-0807506 Ver.2.1

Routine Maintenance : Performance Monitor


Function: To monitor the Link Performance. Procedure: Click Performance Monitor---> Link Performance Monitor button in the NE-specific menu bar.

Link

(PNMTJ>performancemonitor>link performance monitor) 11


NEC-MIC-0807506 Ver.2.1

2. Trouble shooting
For the basic troubleshooting, following method is needed to know by engineer. Alarm status checking Loop back BER measurement Troubleshooting Flow
12 NEC-MIC-0807506 Ver.2.1

2. Trouble shooting
Following items should pay attention during troubleshooting

LED alarm situation ODU Rx=? ODU Tx=? Order wire test DC power supply
13

NEC-MIC-0807506

Ver.2.1

Trouble shooting -alarm checking


How to check the alarm of one link? Basic method is check the alarm first, the microwave equipment has alarm system to instruct

Alarm checking by NMS Alarm checking by LED of IDU

14 NEC-MIC-0807506 Ver.2.1

Trouble shooting -alarm checking on PNMTJ

15 NEC-MIC-0807506 Ver.2.1

Trouble shooting -Alarm checking by PNMSJ&PNMTJ


Alarm checking can use NMS by software PNMSJ (remote checking) or PNMTJ (local checking).
Remote access by PNMSJ
Upper NMS

Local access by PNMTJ

admin

Remote Client Access


Filtered Traps

demo

Managed Digital Radio Network

16 NEC-MIC-0807506 Ver.2.1

Routine Maintenance
-Alarm Checking by NMS

17 NEC-MIC-0807506 Ver.2.1

Routine Maintenance -Alarm Checking by LCT


1. The normal status is in PNMSJ& PNMTJ system is all the board is green. 2. The correlation block of the structure figure of main window will change green into red when the equipment occur fault. So you need log in PNMTJ to check Alarm:
PNMSJ &PNMTJ (START)

PC (Start)

Alarm board (Click)

(Show) alarm status

(an example as following figure), then you can click on red block, and check fault information description.

18 NEC-MIC-0807506 Ver.2.1

Routine Maintenance -ALARM Checking BY PNMTJ

19 NEC-MIC-0807506 Ver.2.1

Trouble shooting -Alarm checking on PNMTJ


Path: PNMTJ>EVENT LOG>CLICK and Checking like upper status

* Detail Alarm inform checking by Event log interface


NEC-MIC-0807506

20 Ver.2.1

Trouble shooting -Alarm checking on LED

Alarm checking on front of IDU LED

NEO 1+0 &NEO/C IDU 1 + 0 Configuration

NEO IDU 1 + 1 Configuration


21 NEC-MIC-0807506 Ver.2.1

Routine Maintenance -Alarm checking by IDU LED


IDU

CTRL Module LED

22 NEC-MIC-0807506 Ver.2.1

Routine Maintenance -Alarm checking by IDU LED


IDU

Modem Module LED

23 NEC-MIC-0807506 Ver.2.1

Trouble shooting
-loop back by PNMTJ
MAINTENANCE - PDH MAINTENANCE - SDH

24 NEC-MIC-0807506 Ver.2.1

Trouble shooting
Function: To loop back the MUX signal at the IF Procedure: (Maintenance mode must be ON) Click IF Loop back button in Maintenance menu

-loop back by PNMTJ

Function: To conduct DADE adjustment Procedure: (Maintenance mode must be ON) Click DADE Adjust button in Maintenance menu
25 NEC-MIC-0807506 Ver.2.1

Trouble shooting

-loop back by PNMTJ


Function: To loop back the signal sent from selected NE via the INTFC Procedure: (Maintenance mode must be ON) Click Main Loopback-1(INTFC)button in Maintenance menu For
PDH

For SDH

200894 NEC-MIC-0807506

NEC Corporation 2007

26 Ver.2.1

Trouble shooting

-loop back by PNMTJ


Function: To loop back the signal sent from the opposite NE at selected NE Procedure: (Maintenance mode must be ON) Click Main Loopback-2 button in Maintenance menu
For PDH

For SDH

200894 NEC-MIC-0807506

NEC Corporation 2007

27 Ver.2.1

Trouble shooting

-loop back by PNMTJ


PDH- NEAR END / FAR END

SDH- NEAR END / FAR END

28 NEC-MIC-0807506 Ver.2.1

Trouble shooting

BER measurement

BER TEST is used for the PDH bit error test

Notes : For the one PDH channel bit error test , the opposite relate channel need to be done loop back at same time!
29 NEC-MIC-0807506 Ver.2.1

Trouble shooting

BER measurement

SDH analyzer is used in SDH channel bit error Test


TX/RX

Notes : For the one SDH channel connect with analyzer to make bit error test , the opposite relate SDH channel need to be done loop back at same time!
30 NEC-MIC-0807506 Ver.2.1

Troubleshooting flow

31 NEC-MIC-0807506 Ver.2.1

Troubleshooting Procedure
On NMS center: 1, 2, 3, 4, Service quality down Check networks through NMS system Problem location: MW or BTS? For MW problem collect information remotely with help of your local maint. staffs. 5, Solve problem by your local staffs, or dispatch expert to site with suitable spares. On site: 1, 2, 3, 4, Check by PNMT, or LCT Adjust antenna for antenna moving Check IF cable, DC connector for poor installation Replace IDU, ODU for hardware problem.
32 NEC-MIC-0807506 Ver.2.1

Trouble shooting

-Fault isolation

33 NEC-MIC-0807506 Ver.2.1

Troubleshooting

Fault equipment changing procedure when troubleshooting


ODU trouble shooting flow IDU ODU trouble shooting flow

34 NEC-MIC-0807506 Ver.2.1

Start

IF in put Alarm?

IF cable length?

Change IF Cable

MOD DEM Alarm IDU

Change IF Cable IF in put Alarm?

Replace IDU

Replace ODU

APC1 APC2 Alarm?

Freq. setting ?

Resetting freq.

Replace ODU Tx POW Alarm? Replace ODU

MW is OK!

35 NEC-MIC-0807506 Ver.2.1

Start

APC1 APC2 Alarm?

Freq. setting ?

Resetting freq.

Replace ODU

Rx level alarm?

Opposite ODU OK?

Opposite ODU fails

Freq. setting ?

Resetting freq.

Rx Level less 1V

Antenna sys problem

MW OK

Replace ODU

36 NEC-MIC-0807506 Ver.2.1

MOD ALM

Replace IDU
Replace IDU

TX DPU ALM

Replace IDU TX CPU ALM Replace IDU

TX CLK LOSS

Replace IDU Replace IDU

MUX ALM

Replace IDU
Replace IDU and ODU

Replace IDU

OPR ALM

Grounding system or IDU,ODU IF cable connector

Input ALM

IF Cable connector

Correct connector

Equipment OK

120, 75 setting Replace IDU

Correct Imp setting

Replace IDU
NEC-MIC-0807506

37 Ver.2.1

38 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

ODU replacement

39 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

ODU Replacement

40 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

ODU Replacement

41 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

Waterproof for ODU

42 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

IDU replace

43 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

IDU Replacement

44 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /

IDU Replace

To replace the MODEM module

45 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /
To remove IDU

IDU Replace To Mount the IDU

46 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement /Fuse Replacement

47 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement
Important points for Unit replace-1
1, Prepare correct type of equipment 2, Turn off DC power before replace IDU and ODU 3, Check ODU: Tx high always working with Tx low 4, 7G,8G Paso+ ODU is point freq. unit. Its freq. has to setting same with printed freq. on ODU 5, Normal DC supply Paso+: 40 60V; Paso is 20-70V

48 NEC-MIC-0807506 Ver.2.1

Troubleshooting

-Fault replacement
Important points for Unit replace-2
6, IDU ID setting should same on both side of one link 7, DEM maybe setting to ON for 7, 8G ODU 8, Check IF cable impedance: about 100M OHM for open, about 10K OHM with ODU. 9, Mark damage equipment, send it to NEC on time. 10,Check installation situation for frequent equipment damage on same site.

49 NEC-MIC-0807506 Ver.2.1

Trouble

-Examples 1

shooting

Sebah019 link problem, BTS alarm, Check Rx lower -70dBm Check Opposite Rx level -70dBm Tx out put OK

A: Rx -70dBm

B: Rx -70dBm

Problem on antenna system----antenna misallignment , change the antenna allignment, the service was ok.
Note: Long term Rx down on both site, problem on antenna system, propagation section. Short term Rx down on both side problem relative to fading or poor IF cable Connection. 50 NEC-MIC-0807506 Ver.2.1

Case1 Troubleshooting Summary


1. phenomena BTS service down, MW link is off; two side ODU alarm. a. b. c. d. One side fault? Water influence ? ODU lightning strike ? Antenna ?

2.

Analysis

3.

Measure

Step by step to insulate the problem, and then concentrate the problem was Antenna miss alignment ; After alignment again the MW link was ok, the BTS signal was normal.
51

4.

Result

NEC-MIC-0807506

Ver.2.1

Trouble shooting -Examples 2


Eajadabia link problem Check Rx lower ***dBm Check Opposite Rx level -34dBm Problem on ODU! --------replace ODU with spares
Note: One site Rx down, problem on ODU.
A: Rx ***dBm B: Rx -34dBm

52 NEC-MIC-0807506 Ver.2.1

Case2 Troubleshooting Summary


1. phenomena BTS service down, MW link is off; the A side ODU alarm ,IDU alarm. a. b. c. d. Configuration problem? Water influence ? A side IF cable normal ? ODU lightning strike ?

2.

Analysis

3.

Measure

Step by step to insulate the problem, and then concentrate the problem was ODU problem ; After change to new ODU (same band with same sub-band) , MW link was ok, the BTS signal was normal.

4.

Result

53 Ver.2.1

NEC-MIC-0807506

Maintenance summary
Maintenance activity include Routine maintenance and troubleshooting. Alarm checking is very important operation in maintenance, after checking Alarm, we can analysis when kind of trouble system possible have. For troubleshooting follow thing need careful before installation.
1, poor operation situation Temperature over equipment specification, water damage, Lighting damage by poor grounding system, DC power supply problem, new building affection etc. 2, poor installation poor Antenna fix, poor IF cable connector assembly, E1 cable short circuit or opening, IF connector short circuit etc. 3, Un suitable transportation
54 NEC-MIC-0807506 Ver.2.1

Question

&

Answer

1 How to check the alarm?


check the IDU or check the PNMTJ.

2 How to trouble shooting the link?


check the IDU indicator or check the PNMTJ alarm pannel.

3 How to check the link performance?


remote connect PNMSJ or local connect the PNMTJ software to IDU, click the manus of performance monitor>link performance monitor> check the link performance by PNMTJ software. The error data should be 0.

4 How to connect the link status by PNMTJ?


local connect the PC to one of the IDU of one link , then start the PNMTJ software.

5 How to remote control IDU?


check the IDU through network by the PNMSJ.

55 NEC-MIC-0807506 Ver.2.1