You are on page 1of 5

N2XB(AL)Y (16-800) mm 0.6/1 N2XB(AL)Y 11 xx (16-800) mm 0.

6/1 kV kV
Cu / XLPE / ATA / PVC
(Copper Conductor, XLPE Insulated, Aluminium Tape Armor, PVC Sheathed) Standard Specification : IEC 60502-1

Construction Data
Nom. Cross Section Area mm 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 Overall Diameter approx. mm 15.4 15.6 16.7 18.5 20.5 22.5 24.0 26.0 28.5 31.5 34.5 38.0 42.5 47.5 52.5 Cable Weight approx. kg/km 386 460 567 731 957 1,215 1,472 1,756 2,168 2,770 3,345 4,250 5,380 6,947 8,702
Note : Conductor Shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 800 sqmm supplied in non compacted circular stranded (rm) or compacted circular stranded (cm) conductor shape Standard Packing 16 - 300 sqmm supplied in wooden drum @ 1000 m 400 - 800 sqmm supplied wooden drum on available length Length Tolerance per drum 2% Application : For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur. Special Features on Request Fire Resistance Oil Resistance UV Resistance Flame Retardant Cat. A, B, C Flame Retardant Non Category Anti Termite Anti Rodent Low Smoke Zero Halogen
Copper Conductor XLPE Insulation PVC Inner Sheath Aluminium Tape Armor PVC Sheath

Electrical Data
Conductor Nom. Cross Sect. DC Resistance at 20C Max. (/km) 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 0.0221 AC Resistance at 90C Max. (/km) 1.466 0.927 0.668 0.494 0.342 0.247 0.196 0.159 0.128 0.099 0.080 0.064 0.052 0.042 0.035 Inductance Trefoil formation Flat formation Current - Carrying Capacity at 30 C * in air Max. (A) 118 154 188 229 287 352 407 465 537 636 728 838 960 1092 1216 in ground Max. (A) 118 153 183 217 265 317 359 402 453 523 585 655 731 807 877 in air Max. (A) 121 158 193 235 295 361 418 476 549 648 739 846 964 1087 1202 in ground Max. (A) 121 157 188 223 272 324 367 410 461 529 590 657 728 797 858 Short circuit current at 1 sec Max. (kA) 2.29 3.58 5.01 7.15 10.01 13.59 17.16 21.45 26.46 34.32 42.90 57.20 71.50 90.09 114.40

(mm) 16 25 35 50 70 95

(mH/km) 0.412 0.366 0.349 0.332 0.318 0.304 0.296 0.292 0.286 0.277 0.272 0.270 0.266 0.261 0.259

(mH/km) 0.458 0.412 0.395 0.378 0.364 0.350 0.342 0.338 0.332 0.323 0.318 0.317 0.312 0.307 0.305

120 150 185 240 300 400 500 630 800

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

16733-01 Rev. 2.0 / 2009

N2XBY (1.5-300) mm 0.6/1 N2XBY 22xx (1.5-300) mm 0.6/1 kV kV


Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Tape Armor, PVC Sheathed) Standard Specification : IEC 60502-1

Construction Data
Nom. Cross Section Area mm 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Overall Diameter approx. mm 14.4 14.4 14.4 15.4 17.4 19.4 22.5 25.0 28.0 32.0 35.5 40.5 45.0 50.0 55.5 61.0 Cable Weight approx. kg/km 293 310 328 397 533 705 986 1,252 1,529 2,081 2,739 3,726 4,518 5,537 6,987 8,514
Note : Conductor Shape 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape Standard Packing 1.5 - 120 sqmm supplied in wooden drum @ 1000 m 150 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum 2% Application : For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur. Special Features on Request Fire Resistance Oil Resistance UV Resistance Flame Retardant Cat. A, B, C Flame Retardant Non Category Anti Termite Anti Rodent Low Smoke Zero Halogen
Copper Conductor XLPE Insulation PVC Inner Sheath Galvanized Steel Tape Armor

PVC Sheath

Electrical Data
Conductor Nom. Cross Sect. DC Resistance at 20C Max. (mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 (/km) 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 AC Resistance at 90C Max. (/km) 15.429 9.449 5.878 3.927 2.334 1.467 0.927 0.669 0.494 0.342 0.247 0.196 0.160 0.128 0.099 0.080 (mH/km) 0.328 0.304 0.275 0.263 0.248 0.238 0.240 0.233 0.232 0.229 0.224 0.223 0.224 0.225 0.223 0.221 Inductance Current - Carrying Capacity at 30C * in air Max. (A) 29 39 51 65 89 118 157 193 233 295 360 423 482 551 652 744 in ground Max. (A) 34 45 59 74 100 130 167 201 239 293 350 401 449 505 584 656 Short circuit current at 1 sec

Max. (kA) 0.21 0.36 0.57 0.86 1.43 2.29 3.58 5.01 7.15 10.01 13.59 17.16 21.45 26.46 34.32
16733-02 Rev. 2.0 / 2009

42.90

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

N2XBY (1.5-300) mm 0.6/1 N2XBY 33xx (1.5-300) mm 0.6/1 kV kV


Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Tape Armor, PVC Sheathed) Standard Specification : IEC 60502-1

Construction Data
Nom. Cross Section Area mm 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Overall Diameter approx. mm 14.4 14.4 15.0 16.2 18.2 20.5 24.0 26.5 28.5 32.5 36.0 41.0 45.5 50.0 56.0 61.0 Cable Weight approx. kg/km 304 324 377 463 638 860 1,223 1,574 1,818 2,518 3,335 4,451 5,449 6,656 8,514 10,375
Note : Conductor Shape 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor Standard Packing 1.5 - 95 sqmm supplied in wooden drum @ 1000 m 120 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum 2% Application : For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur. Special Features on Request Fire Resistance Oil Resistance UV Resistance Flame Retardant Cat. A, B, C Flame Retardant Non Category Anti Termite Anti Rodent Low Smoke Zero Halogen
Copper Conductor XLPE Insulation PVC Inner Sheath Galvanized Steel Tape Armor

PVC Sheath

Electrical Data
Conductor Nom. Cross Sect. DC Resistance at 20C Max. (mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 (/km) 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 AC Resistance at 90C Max. (/km) 15.429 9.449 5.878 3.927 2.334 1.467 0.927 0.669 0.494 0.342 0.247 0.196 0.160 0.128 0.099 0.080 (mH/km) 0.328 0.293 0.275 0.263 0.248 0.238 0.240 0.233 0.232 0.229 0.224 0.223 0.224 0.225 0.223 0.221 Inductance Current - Carrying Capacity at 30C * in air Max. (A) 25 33 43 55 75 100 133 164 202 255 312 366 418 483 569 652 in ground Max. (A) 29 38 50 62 84 109 140 169 205 250 299 342 382 433 499 561 Short circuit current at 1 sec

Max. (kA) 0.21 0.36 0.57 0.86 1.43 2.29 3.58 5.01 7.15 10.01 13.59 17.16 21.45 26.46 34.32
16733-03 Rev. 2.0 / 2009

42.90

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

N2XBY (1.5-300) mm 0.6/1 N2XBY 44xx (1.5-300) mm 0.6/1 kV kV


Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Tape Armor, PVC Sheathed) Standard Specification : IEC 60502-1

Construction Data
Nom. Cross Section Area mm 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 Overall Diameter approx. mm 14.4 14.7 16.0 17.4 19.7 22.5 26.0 29.0 32.5 37.0 42.5 47.5 53.5 57.5 64.0 69.5 Cable Weight approx. kg/km 310 347 440 548 773 1,055 1,517 1,967 2,356 3,260 4,727 5,823 7,104 8,651 11,087 13,530
Note : Conductor Shape 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 35 sqmm supplied in compacted circular stranded (cm) conductor shape 50 - 300 sqmm supplied in sector shaped stranded (sm) conductor Standard Packing 1.5 - 70 sqmm supplied in wooden drum @ 1000 m 95 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum 2%Length Tolerance per drum 2% Application : For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur. Special Features on Request : Fire Resistance Oil Resistance UV Resistance Flame Retardant Cat. A, B, C Flame Retardant Non Category Anti Termite Anti Rodent Low Smoke Zero Halogen
Copper Conductor XLPE Insulation PVC Inner Sheath Galvanized Steel Tape Armor PVC Sheath

Electrical Data
Conductor Nom. Cross Sect. DC Resistance at 20C Max. (mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 (/km) 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 AC Resistance at 90C Max. (/km) 15.429 9.449 5.878 3.927 2.334 1.467 0.927 0.669 0.494 0.342 0.247 0.196 0.160 0.128 0.099 0.080 (mH/km) 0.315 0.293 0.275 0.263 0.248 0.238 0.240 0.233 0.232 0.229 0.224 0.223 0.224 0.225 0.223 0.221 Inductance Current - Carrying Capacity at 30C * in air Max. (A) 27 36 48 60 83 110 148 183 214 269 334 386 449 512 604 692 in ground Max. (A) 32 42 55 68 91 118 152 183 210 256 309 350 395 444 513 577 Short circuit current at 1 sec

Max. (kA) 0.21 0.36 0.57 0.86 1.43 2.29 3.58 5.01 7.15 10.01 13.59 17.16 21.45 26.46 34.32
16733-04 Rev. 2.0 / 2009

42.90

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

N2XBY (1.5-50) mm 0.6/1 N2XBY 55xx (1.5-50) mm 0.6/1 kV kV


Cu / XLPE / STA / PVC
(Copper Conductor, XLPE Insulated, Galvanized Steel Tape Armor, PVC Sheathed) Standard Specification : IEC 60502-1

Construction Data
Nom. Cross Section Area mm 1.5 2.5 4 6 10 16 25 35 50 Overall Diameter approx. mm 14.4 15.7 17.2 18.7 21.5 24.5 28.5 32.0 36.0 Cable Weight approx. kg/km 322 403 517 649 919 1,265 1,833 2,403 3,069
Note : Conductor Shape 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape Standard Packing 1.5 - 50 sqmm supplied in wooden drum @ 1000 m Length Tolerance per drum 2% Application : For installation indoors, cable channels and in ground, for industry installations, switchgear, and power station, if there is a risk that low mechanical damage may occur. Special Features on Request Fire Resistance Oil Resistance UV Resistance Flame Retardant Cat. A, B, C Flame Retardant Non Category Anti Termite Anti Rodent Low Smoke Zero Halogen
PVC Filler Copper Conductor XLPE Insulation PVC Inner Sheath Galvanized Steel Tape Armor PVC Sheath

Electrical Data
Conductor Nom. Cross Sect. DC Resistance at 20C Max. (mm) 1.5 2.5 4 6 10 16 25 35 50 (/km) 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 AC Resistance at 90C Max. (/km) 15.429 9.449 5.878 3.927 2.334 1.467 0.927 0.669 0.494 (mH/km) 0.315 0.293 0.275 0.263 0.248 0.238 0.240 0.233 0.232 Inductance Current - Carrying Capacity at 30C * in air Max. (A) 28 37 49 62 86 114 154 190 230 in ground Max. (A) 33 43 55 69 92 120 155 186 219 Short circuit current at 1 sec

Max. (kA) 0.21 0.36 0.57 0.86 1.43 2.29 3.58 5.01 7.15

www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

16733-05 Rev. 2.0 / 2009