Construction of Multistories Residential flats and Office Complex for ONGC at Annanagar Western Extension, Chennai - 600 Tamil

Nadu, India. TNBP/ Sl. No Description of item/Work Unit QTY NBC No. CIVIL WORKS PILE WORKS BORED PILE WORKS (Cast in Situ) 1 Mobilisation of pile rig and its related equipments, 30A bringing into site of all plant and machinery along with accessories etc.. including transportation and installation of vertical cast in situ bored piles of following diameter using reinforced cement concrete Design Mix M30 Grade by setting the bored cast in situ pile equipments with all accessories and tools at each locations based on the sequence of operations as directed by the Engineer-incharge., boring for the piles from ground level in all soils to the required depth below cut off level to carry a safe working load not less than specified, by Direct Mud Circulation Method ( using bentenite clay of required density) inclusive of pile accessories, temporary casing pipe, bentenite solution of 10% of concrete with required density and routine test as per IS 2911 (Part- IV) -1985 etc. complete as directed by the Engineer-in-charge.. excluding the cost of steel and fabrication reinforcement grills but including Bentenite solution to carry safe working load not less than specified, machinery charges, labour charges and assembling, erecting the equipment and dismantling, trimming the pile concrete above cutoff level, cleaning the debris & slushy, carting away the surplus from the site inclusive of loading and unloading of transportation, the cost of shoe and the length of the pile to be embedded in the pile cap and removal of plant and machinery from site after completion of work. etc.,all complete, complying with relevant standard specification and as directed by the Engineer-in-charge.. (Pile shall be measured from the top of the shoe to the bottom of the pile cap.) Design Mix M30 Grade concrete should be prepared with ordinary Portland Cement with water cement ratio not exceeding 0.45 including the use of Plasticizer of required Grade and Hard Broken Granite Stone Jelly of 20mm size and down graded as per requirement. Mix Design Data has to be got approved by the Engineer-Incharge before commencement of work. a b c 500mm dia pile of 98 MT safe load 600mm dia pile of 141 MT safe load 750mm dia pile of 220 MT safe load RMT RMT RMT 10419 6210 1380

Vertical load testing of piles in accordance with IS 2911 ( part iv) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc, as per specification and as directed by the Engineer-in-charge... Initial test upto 100 tonne capacity pile. Above100 tonne and upto 200 tonne capacity pile. Above200 tonne and upto 400 tonne capacity pile. Total of Bored Pile Works EARTH WORK EXCAVATION 23 V, VI Earth work excavation for foundation in all type of soils S2 and sub soils to the required depth as may be directed including dense soil, disintegrated/weathered/soft rock not requiring blasting for Footings of columns, Pile caps and hydrant trenches, catch basins,collection chambers, boundary walls, security cabins, rainwater harvesting pit,Tennis court etc.including manual excavation for levelling, dressing of sides and ramming of bottom with all leads and lifts,shoring,strutting and bailing out water wherever necessary etc.all complete as directed by Engineer-Incharge.

a b c

Nos. Nos. Nos.

5 5 1

a b 4

0 to 2m depth. 2 to 3m depth. 23 & 24 V, Earth work excavation in open excavation in all type of VI S2 soils including stiff clay for UG Sump. STP etc.,including levelling, dressing of sides and ramming of bottom with all leads and lifts, shoring, strutting and bailing out water wherever necessary etc.. all complete as directed by Engineer-Incharge. 0 to 2m depth. 2 to 3m depth. 3 to 4m depth. 4 to 5m depth. 5 to 6m depth. 6 to 7m depth.

Cum Cum

8786 203

a b c d e f

Cum Cum Cum Cum Cum Cum

1100 550 550 550 447 1100

24 & 25 V, Supplying and filling in foundations and the area VIS2 wherever specified with approved good quality filling materials in plinths, area development etc. wherever specified in layers of not exceeding 150 mm thick including breaking clods,storing,transportation ,double handling, watering, compacting each layer with vibratory compactor and at un-accessible places with wooden/steel rammers to achieve 95% proctor density at optimum moisture content, all leads and lifts, bailing/ pumping out of water to keep site dry while backfilling; cost shall include conveyance of all materials, labour, machinery etc. complete as directed.The rate to includes loading, unloading, hire and fuel charges for tools and plants and other incidental charges etc., as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. Approved quality gravel Approved quality river sand Quarry dust Filling with excavated earth with necessary ramming Carting away surplus earth/excavated material/debris and like materials outside the site and disposing off the same to the outside the city limit as directed by the Engineer-in-charge for dumping of such material,including spreading etc.,as per the norms by the local authorities. Total of Earth work Excavation Works ANTI-TERMITE TREATMENT Providing Pre - construction Anti - termite treatment and creating a chemical barrier to the building by injecting chemical emulsion of required concentration under grade slab and grade beam, all round the Pile Caps, Catch basins, trenches, pits, tunnels, wall trenches, back fill, plinth filling, junction of wall and floor. External perimeter of building, surrounding of pipes, expansion joints, below U.G. sump and retaining/side walls etc. as per instructions of chemical manufacturer as directed by the Department officer/ Architect. The treatment shall be carried out strictly in accordance with the technical specification and conforming to IS 6313 or equivalent BS specification. The chemical to be used as insecticide for the treatment shall be Biflex Tc, TC stands for Termiticide Concentrate for Termite Control (Bifenthrin) and the application shall be diluted 1 part of chemical Biflex Tc with 49 parts of water to get 0.05% emulsion and strictly in accordance with the manufacturers specification. Cum Cum Cum Cum Cum 9888 744 11340 3600 7478

a b c d 6

The work should be carried out by an approved and registered specialist pest control agency only. Tenderer to furnish the name of the proposed specialist firm. A 10 years post application guarantee against defects shall be furnished by the main Contractor. Note : Horizontal plan area at ground floor level of the building will be measured and paid. The chemical to be used for the treatment and concentration of the chemical solutions should be as laid down in IS - 6313 Part II.as directed by the Engineer-incharge. Total of Anti Termite Works 8 CONCRETE WORKS 28 V, VI Providing and laying plain cement concrete 1:5:10 (1 of S2 (SS.A) cement : 5 of course sand : 10 of hard broken stone jelly ) VII using coarse graded aggregate of 40 mm for levelling course under floors ( Ground Floor level ) etc. including form work wherever necessary and well compacted etc. all complete, as directed by the Engineer-in-charge... 28 V, VI Providing and laying plain cement concrete 1:4:8 (1 of S2 (SS.A) cement : 4 of course sand : 8 of hard broken stone jelly VII )using coarse graded aggregate of 40 mm for levelling course under pilecaps, steps, walls, platform etc. including form work wherever necessary and well compacted etc. all complete, as directed. and as directed by the Engineer-in-charge.. 28 V, VI Providing and laying P.C.C. 1:3:6 (1 of cement : 3 of (S2) (S5A) course sand : 6 of hard broken stone jelly ) of specified VII thick wherever specified using river sand, 20mm including base reperation, Compaction, levelling for drains, trenches and collection chamber all leads and lifts, curing for all structures at all locations etc., Complete .(Footings)s and as directed by the Engineer-in-charge.. Total of Concrete Works REINFORCED CEMENT CONCRETE (RMC) DESIGN MIX CONCRETE NOTE: RMC SHALL BE PROCURED FROM SITE BATCHING PLANT

Sqm.

5115

Cum

421

Cum

210

10

Cum

747

11

Cement Concrete M30 Design Mix for all reinforced cement concrete works namely Pile cap,Grade beam, Raft Slab,Retaining walls,Shear wall,RCC walls,Lift walls,Plinth beams, Column,Column footings,Grade slab,Roof slab & beam,Curved beams, Grid beams,Flat slab / Column drops,Pergola,Staircase waist and landing slab lintel, Sunshades, parapet cum drops, Steps,canopy, fin projects, window boxing slab, Loft,chajjas,Planter box,Deck slab and other similar works and other similar structures etc..using ordinary Portland cement of grade 53 from approved manufacturer, river sand, 20mm and down size coarse aggregates, necessary approved admixtures as per requirement and using fly ash content not excedding the 15 % in structural and non structural works excluding the cost of reinforcement grills, fabrication charges, shuttering and centering but including all leads and lifts,pumping using line pump or boom placer, scaffolding wherever necessary,laying,vibrating, finishing, curing etc all complete complying with relevant standard specification & as directed by the Engineer-in-charge.. Mix Design Data has to be got approved by the Engineerin-charge. before commencement of work. etc. complete (Design mix shall be as approved by the Engineer-incharge.)

a i ii iii b c d e f g h i j k l m n o p q r s t u

M30 GRADE (Structural Concrete) In Foundation and Plinth Upto 1.5 M depth From 1.5 M to 4.5 M depth From 4.5 M depth to 9 M depth Ground/Stilt Floor First Floor Second Floor Third Floor Fourth Floor Fifth Floor Sixth Floor Seventh Floor Eighth Floor Ninth Floor Tenth Floor Eleventh Floor Twelfth Floor Thirteenth Floor Fourteenth Floor Fifteenth Floor Sixteenth Floor Seventeenth Floor Eighteenth Floor Terrace Floor-1

Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum

4451 396 97 1527 1478 1258 1127 428 298 298 298 298 298 298 298 300 205 195 195 195 198 122 76

v 12

Terrace Floor-2 Supplying and fixing of Precast slab for the following thickness made in CC 1:1.5:3 (One cement, one and half fine aggregate and three coarse aggregate) using 12mm size hard broken stone jelly including the cost of slab, moulding, laying,finishing smooth 6mm thick cement plaster 1:3 (one cement and three fine aggregate) on exposed surfaces, curing, transportation, pointing, and also include for providing necessary MS angles of required size based on the thickness of precast slab and to be fixed on the edges of the precast slab including grouting the lugs with Cement concrete 1:1.5:3, for approach slab and other similar works but excluding cost of reinforcement and as directed by the Engineer-incharge.. 100mm thick Precast slab 75mm thick Precast slab Providing, precasting and placing to the required gradient, M25 grade precast Concrete cover slab of 50mm thick with perforation of size as specified in drawings over storm water drain / trenches / ducts / pullout chambers etc., as per the drawing including reinforcement, addition of polypropelene fibers, casting in yards, curing, edge protection of all edges using ISA 25x25x4, finishing all surfaces with all leads and lifts, transportation, placing, cost of PVC sleeves, MS hooks, finishing the joints with CM 1:3 curing etc., complete as directed by Engineer-Incharge. Providing and fixing reinforcement for RCC work with Thermo Mechanically Treated Bars (TMT) or equivalent HYSD bar of various diameters and grade of steel conforming to IS 1786 latest version specification including cutting and waste, bending, hoisting, fabricating and placing in position according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing precast cement concrete / approved PVC cover blocks for placing the reinforcements in position and for maintaining the cover specified and / or according to relevant IS codes.Rate to include transport from the plant to site of work etc., complete as directed by the Engineer-in-charge..

Cum

68

a b 13

Sqm. Sqm. Sqm.

720 379 1971

14

Note : Unless noted otherwise the measurements in accordance with IS 1200. However reinforcement shall be measured only in lengths of bars as actually placed in position on standard weight basis, no allowance being made in the weight for rolling margin. Authorised laps and splices only will be measured. Chairs of any shape & profile, Spacer bar of any shape & profile, cover block, wastage and binding wire will not be measured and shall be included in the quoted rates. Quoted rate shall be deemed to have considered the above stipulation. Quoted rate to include lead, lift, placing at all levels and as directed. a Grade of reinforced steel - Fe 500 - TMT bars Total of RCC Works FORM WORK Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc complete. 30(S) 86 86 All reinforced cement concrete Footings, plinth beam, pile A V, VI cap, staircase steps, sill beam, grade beams & slab etc. (S3) VII Columns,(Rectangular/Square) chajjas, loft and sunshades etc for all floors Lintels, conventional slab & beams, staircase waist slab & landings, pergolas, etc for all floors Walls (any thickness) including, core walls, shear wall, retaining wall, parapet wall etc. for all floors. Extra for additional height in centering, shuttering wherever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.30m ( height shall be the dimension as measured from the top of the lower slab / pcc sub base to the bottom of the subsequent upper slab / soffit of the beam as the case may be.) , for every additional height of 1m or part thereof for: (Plan area to be measured). Suspended floors, flat slabs, drops, post tensioned slabs, slabs curved in plan to any radius, grid slab, roofs, landings, beams including spiral and curved beams of all radius, post tensioned beams, grid beams, plinth beams, girders, bressumers, cantilevers and balconies. Total of Formwork Works MASONRY WORKS Sqm. 9920 MT 2925

15

b c d 16

Sqm. Sqm. Sqm. Sqm.

22708 42757 3648 11153

17

31 & similar to 31C V, VI (S5) VII

18

a b c d e f g h i j k l m n o p q r s 19

20

Brick work with II class ground moulded well burnt chamber bricks of size 9"x4-1/2"x3" (23x115x7.5 cm)with minimum compressive strength of 50 Kg per Sq.cm. in cement mortar 1:5 (1cement : 5 coarse sand) etc. complete and as directed by the Engineer-in-charge.. - For Foundation and Basement 31 & Brick work with II class ground moulded well burnt similar to chamber bricks of size 9"x4-1/2"x3" (23x115x7.5 cm) with 31C V, VI minimum compressive strength of 50 Kg per Sq.cm. in (S5) VII cement mortar 1:6 ( 1cement : 6 coarse sand) for superstructure at all levels etc. complete and as directed by the Engineer-in-charge.. Ground/Stilt Floor First Floor Second Floor Third Floor Fourth Floor Fifth Floor Sixth Floor Seventh Floor Eighth Floor Ninth Floor Tenth Floor Eleventh Floor Twelfth Floor Thirteenth Floor Fourteenth Floor Fifteenth Floor Sixteenth Floor Seventeenth Floor Eighteenth Floor 35-J&K Providing and constructing Cement Concrete Solid Block Masonry in cement mortar 1:5 ( one cement and five coarse sand ) 190mm thick for Foundations using precast machine moulded blocks using standard size of 390 x 190 mm of solid cement concrete blocks with minimum compressive strength of 5N / Sq.mm conforming to IS 2185 or equivalent BS including all scaffolding, staging, curing, and all leads etc. complete and as directed by the Engineer-in-charge.. 35-J&K Providing and constructing Cement Concrete Solid Block Masonry in cement mortar 1:6 ( one cement and five coarse sand ) 190mm thick for Super structure in the following floors using precast machine moulded blocks at all levels using standard size of 390 x 190 mm of solid cement concrete blocks with minimum compressive strength of 5N / Sq.mm conforming to IS 2185 or equivalent BS including all scaffolding, staging, curing, all lifts and leads etc. complete and as directed by the Engineer-Incharge. Ground/Stilt Floor First Floor Second Floor

Cum

906

Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Cum Sqm.

58 40 33 33 33 35 35 35 35 35 35 35 26 26 26 26 30 13 15 188

a b c

Sqm. Sqm. Sqm.

1859 913 976

d e 21

Third Floor Fourth Floor Providing and constructing Cement Concrete Solid Block Masonry in cement mortar 1:5 ( one cement and five coarse sand ) 90mm thick in the following floors using precast machine moulded blocks at all levels using standard size of 390 x 190 mm of solid cement concrete blocks with minimum compressive strength of 5 N/ Sq.mm conforming to IS 2185 or equivalent BS including all scaffolding, staging, curing, all lifts and leads etc. complete and as directed by the Engineer-in-charge. Ground/Stilt Floor First Floor Second Floor Third Floor Providing and constructing Glass Block masonry work at all levels in Fire escape staircase wherever necessary (as per drawing), to be set in sealent of approved quality using standard size of 190x190x80 mm of Glass Brick of approved vendor of approved by Engineer-in-charge / Consultant, manufactured as per Manufacturer's specification etc.. Rate shall include accessories for supporting the system Polystyrene foam over an ezylay frame, Acc-Speed jamb connectors and straight connectors, galvanised reinforced rods and necessary staging and scaffolding arrangement, verticality (Plumb level) of the walls, Skilled labour,loading and unloading, lead & Lift, Tools & Plants, Finishing and curing etc. as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge..

Sqm. Sqm.

650 382

a b c d 22

Sqm. Sqm. Sqm. Sqm. Sqm.

25 13 45 35 116

23

31c

Providing and constructing 115 mm. thick, masonry wall ,at all levels, with approved best quality well chamber burnt moulded bricks(230X115X75mm), with minimum compressive strength of 50 Kg / Sq.cm, in Cement Mortar 1:4 with M20 reinforced cement concrete binders - 80 mm thick, using coarse graded aggregate of 12 mm and downsize, reinforced with 4 nos. of 8 mm dia. Fe-500 grade steel -and 6 mm dia. Mild steel stirrups at 200 mm c/c, and binders placed at 2 M intervals. Rate shall include for cost of reinforcements and tying in postion using binding wire made out of 18 gauge G.I. annealed only or 18 gauge S.S., form work, scaffolding, raking out joints, curing etc complete as directed by the Engineer-in-charge..

a b c d e f

Ground/Stilt Floor First Floor Second Floor Third Floor Fourth Floor Fifth Floor

Sqm. Sqm. Sqm. Sqm. Sqm. Sqm.

74 37 17 17 17 17

g h i j k l m n o p q r s 24

Sixth Floor Seventh Floor Eighth Floor Ninth Floor Tenth Floor Eleventh Floor Twelfth Floor Thirteenth Floor Fourteenth Floor Fifteenth Floor Sixteenth Floor Seventeenth Floor Eighteenth Floor Providing and constructing Autoclaved Cellular (Aerated) Concrete Blocks work at all levels, in cement mortar 1:4 using standard size of 400 x 200 mm , as per approved manufacturer's specification etc. complete and as directed. Blocks manufactured under strict quality control conditions confirming to IS 2185 - Part - 3 latest version shall be used. Rate shall include the following: a) Fixing the panels at all levels and supported on slab soffit with suitable arrangement including necessary staging, scaffolding arrangement, alignment and verticality (plumb level) of the walls. Rate Shall also include cutting necessary grooves / chases of required size and at required height for concealing electrical, plumbing, conduits / pipes, holdfasts, bolts etc. and making good surfaces after concealing is complete. b)Grouting of cores in blocks to complete course for fixing of frames and all joinery works etc complete, as directed. All materials required to carry out all related works including specialised work required around and above opening to receive the Frame and to ensure that the load of the panels are not transferred on to the frames or shutters of the doors, windows and ventilators so as to avoid bending of door frames/shutters and affecting the opening / closing operation of the door shutter. etc complete and as directed. c) Finished work should be sand papered to receive plaster and any unevenness or undulations on the block should be made good by the application putty ) If required to do so the test at an approved laboratory to ensure the compression strength of blocks confirming to IS standards Rate shall include accessories for supporting the system into the ceiling with cleats & Anchor fasteners, scaffolding, loading and unloading, lead & Lift, Tools & Plants etc. complete and as directed. Autoclaved Cellular (Aerated) Concrete Blocks wall of 200 mm thick Ground/Stilt Floor

Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm.

17 17 17 17 17 17 17 17 17 17 23 9 24

i a

Sqm.

1938

b c d e f g h i j k l m n o p q r s t u ii a b c d e f g h i j k l m n o p q r s t

First Floor Second Floor Third Floor Fourth Floor Fifth Floor Sixth Floor Seventh Floor Eighth Floor Ninth Floor Tenth Floor Eleventh Floor Twelfth Floor Thirteenth Floor Fourteenth Floor Fifteenth Floor Sixteenth Floor Seventeenth Floor Eighteenth Floor Terrace Floor-1 Terrace Floor-2 Autoclaved Cellular (Aerated) Concrete Blocks wall of 100 mm thick Ground/Stilt Floor First Floor Second Floor Third Floor Fourth Floor Fifth Floor Sixth Floor Seventh Floor Eighth Floor Ninth Floor Tenth Floor Eleventh Floor Twelfth Floor Thirteenth Floor Fourteenth Floor Fifteenth Floor Sixteenth Floor Seventeenth Floor Eighteenth Floor Terrace Floor-1

Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm.

1587 912 744 744 754 754 754 754 754 754 754 678 487 407 407 507 301 256 262 323

Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm. Sqm.

29 287 305 305 305 281 281 281 281 281 281 281 277 277 277 277 336 115 100 3

25

Extra rate over & above Solid Masonry wall for providing R.C.Binder - 80 mm thick with M20 reinforced cement concrete using coarse graded aggregate of 12 mm and downsize, reinforced with 4 nos. of 8 mm dia. Tor steel and 6 mm dia. Mild steel stirrups at 200 mm c/c and binders placed at intervals not more than 1000 mm, including cost of reinforcements and tying in position using binding wire made out of 18 gauge GI annealed only or 18 gauge SS, form work, scaffolding, all labour, hire and fuel charges for all tools and plants employed and all other incidental charges etc. all complete, as directed by the Engineer-in-charge. Solid block wall of 200mm thick for all floor. Solid block wall of 100mm thick for all floor Total of Masonry Works IRON AND STEEL WORKS 86 & 86A Supply and fixing in position Hot rolled structural steel Members / Sections at all levels and to any shape & profile consisting of MS joists, channels, angles, purlins, runners, insert plates, flats and sag rods with necessary sleeves, bolts and nuts, gratings, pipes including cutting, straightening, welding as per standards for connections including consumables etc.complete. Rate shall include preparation of surface, All MS members shall be painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint and total dry film thickness 225 microns etc. all complete, as directed by the Engineer-in-charge.. Rmt Rmt 17837 4929

a b

26

MT

260

27

Providing and fixing in position Hot rolled structural steel Members / Sections at all levels and to any shape & profile consisting of MS joists, channels, angles, purlins, runners, insert plates, flats and sag rods with necessary sleeves, bolts and nuts, gratings, pipes including cutting, straightening, welding as per standards for connections including consumables etc.complete. Rate shall include preparation of surface, applying two coats of Zinc chromate/Phosphate primer before and after erection and two coats of first quality synthetic enamel paint of approved make after erection, sand blasting etc. complete, as directed by the Engineer-incharge.

MT

42

28

86 & 86A Supplying, fabricating and placing in position M.S.chequered plate of required thickness for duct closing and shafts closing at all floors at all levels with necessary supports such as M.S. angles/M.S. flats including stiffeners to be placed on angle iron frame work. (Frame work, angles, stiffeners will be measured under relevant structural steel item). Rate shall include making necessary cutouts for inserts, All MS members shall be painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint make and total dry film thickness 225 microns. etc all complete complying with relevant standard specifications & as directed by the Engineer-Incharge. 86 & 86A Providing and fixing welded M.S. grills to the window openings,along the compound wall details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall include for two coats of first quality synthetic enamel paint over a coat of zinc phosphate primer, necessary tools & plants, welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Engineer-in-charge. Supplying and fixing Motorised rolling shutters from 84A approved fabricator as per IS 6248 made out of electro galvinized/ galvolume laths of 75 x 1.20 mm size duly interlocked together through their entire length including perforated galvolume lath strip at 1000mm lenght from standard eye level in the amid of shutter and jointed together at the end by end locks mounted plate with arrangements for inside and outside locking with push and pull operation, suspension pipe shaft roller steel pipe conforming to heavy duty as per IS 1161 shall be designed deflection shall not be exceed 5mm per 1m width with M.S. brackets plate size not less than 450 x 450 x 6 mm, M.S. side guide channel thichness shall not be less than 3.14mm with necessary depth as per IS 6248. Rate including the cost of providing and fixing necessary good quality high tensile steel wire springs.

MT

30

29

MT

60

30

Rate including 0.9mm thick GI sheet top cover. Rate includes one coat of grey epoxy primer and automation system comprising of side one operator with manual chain override in case of power failure and key selector etc.. all complete as directed by Engineer-Incharge.

Sqm.

72

31

Supplying and fixing in position of M20 grade 2.28m long RCC precast concrete struts of size 150 mm x 150 mm and 125 mm x 125 mm for bottom and top respectively using and 20 mm and down graded metal for Chain link fencing including necessary shuttering for precasting, oiling, concreting and removing, curing appropriately, including the cost of fabricating and fixing of reinforcements 4 nos of 8 mm dia as main rods and 8mm dia stirrpus at 150 mm ctc. The struts are to be laid in position vertically or diagonally as shown in drawing. The rate shall include the cost of conveyance, material, labour and duties , taxes etc all complete as directed by Engineer-Incharge.

Nos

426

32

33

Providing, supplying and fixing GI Chain link 50 x 50mm using 10 gauge with posts of specified material and of standard design placed steel wire fabric fixed between the posts fitted and fixed with G.I. staples / G.I Bolts complete all as per specifications and drawings and as directed at site. Providing and fixing pre-polished Stainless steel railing using 50mm dia bent to shape as shown in drawing and 32mm dia for vertical and 25mm dia three bracing bar as per drawing. Rate shall be inclusive of fixing the railing into the concrete surface with necessary hardware's, SS caps, grouting for the same etc. complete.(for staircase,balcony,open to sky) and as per drawing SS shall conforming of grade AISI 304.etc. all complete, as directed by the Engineer-in-charge Providing and fixing of GI hand railing, in general it shall be made with 50mm dia bend to shape as shown in drawing fixed at top and three 25mm dia pipe for bracing bar as per drawing. Vertical post shall be 32mm dia Rate shall be inclusive of fixing the railing into the concrete surface with necessary hardware's, GI caps, grouting for the same etc. complete. The rate shall be inclusive of finishing the GI surfaces with Duco paint of approved color to the required level after the base prepration(for staircase height 1050mm) etc. all complete, as directed by the Engineer-in-charge

Sqm.

614

Kgs

11725

34

Rmt

939

35

86,86A

Supplying, fabricating, erecting and fixing in position gates , bottom rail for gates, monkey ladders and all miscellaneous steel works as shown in the drg. or as directed by the Engineer at all heights and depths above and below finished floor level using MS angles channels, rails, tees, plates, flats, rounds, squares etc., of various sizes and other structural steel sections including, straightening, cutting, fabricating, welding, bending to shape bolting, fixing in position, welding to insert plate embedded in concrete and inclusive of the following finishes : I) Sand blasting as specified ii) 2 Coats of epoxy paint over one coat of red oxide primer. etc. all complete, as directed by the Engineer-in-charge Total of Iron & Steel Works

MT

36

FLOORING WORKS 28 & 39 H Providing and laying in panels not more than 20 sqm. in plan granolithic flooring with cement concrete 1:2:4 by using coarse graded aggregate of 6 to 12 mm size laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. The screed shall be laid for effective separation of panels not exceeding 20 sqm. in plan etc. complete as per Specifications and as directed. Unevenness in floor finish shall not exceed +2mm in one squaremetre area. Rate to include lead , lift at all levels, pumping, placing, necessary formwork, curing etc., all complete, as directed by the Engineer-in-charge 50 mm thick. 40 mm thick. Providing and laying self levelling epoxy of 1000 micron thick joint less floor topping from approved make, application over the granolithic flooring as per approved manufacturer's specification, including preparation of surface, application, wastage, equipment, tools and plants, work at all levels etc. complete as directed by the Engineer-in-charge.. Providing flooring with best quality approved make White ceramic tiles ranges, Size of tiles shall be 6mm thick of 305 x 305 mm size set in CM 1:4, 20mm thick and pointing the joints with Laticrete and pointing with Laticrete of approved make and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, and protecting and with Gypsum / POP layer over Plastic sheet and removing the same before handing over, work at all levels etc. as complete in all respects and complying with relevant standard specifications and as directed by the Engineer-incharge..( Over Head Tanks & U.G.Sump) Sqm. Sqm. Sqm. 3241 1255 777

a b 37

38

Sqm.

715

39

39A

Providing and fixing wall dado with best quality approved make White Glossy ceramic tiles ranges, sizes 150 x 150 mm x 6 mm thick set in CM 1:2, 10mm thick and pointing with white cement and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, work at all levels etc. as complete in all respects and complying with relevant standard specifications and as directed by the Engineerincharge.( Over Head Tanks & U.G.Sump) Total of Flooring Works

Sqm.

1158

40

56&57

INTERNAL & EXTERNAL FINISHES Plastering to R.C walls, slabs, peripheral beams and columns with Cement Mortar 1:3,(1cement : 3 fine sand) 10 mm thick according to the specification. Rate shall include for necessary hacking,staging,scafolding and curing at all levels and elevations etc.complete as directed. and as directed by the Engineer-incharge. Plastering for external surfaces with 12 mm thick in Cement Mortar 1:5 (1 cement : 5 fine sand ) and as directed. Rate shall include for include for providing and fixing of GI plastermesh and corner bead inluding necessary hacking,staging,scafolding and curing at all levels and elevations and for providing drip bands / moulds / grooves to any size and shape as directed by the Engineer-in-charge.. Applying white washing three coats to ceilings and walls with pure shell lime or fat lime conforming to IS-712 all as per Specification including cost of lime, brush etc.. complying with relevant standard specification, as directed by the Engineer-in-charge. . Providing and applying External texture paint of approved colour and Granito Spray (1947) of Spectrum paints or equivalent approved make . Rate shall include surface preparation, with two coats of primer and 2 coats of natural granite based approved Granito Spray (Grey colour) Paint followed by two coats of silicon based clear coat for excellent weatherability and contrast grooves as per manufacturer specification with necessary staging,scaffolding etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge..

Sqm.

26204

41

56&57

Sqm.

81634

42

63

Sqm.

11741

43

Sqm.

7037

44

Providing and applying External texture paint of approved colour and Granito Smooth (1901) of Spectrum paints or equivalent approved make . Rate shall include surface preparation, with two coats of primer and 2 coats of sand,silica and mica based approved Texture Paint followed by two coats of silicon based clear coat for excellent protection and weatherability and contrast grooves as per manufacturer specification with necessary staging,scaffolding etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.. Providing and applying External texture paint of approved colour and Rustic fine (1004) texture of Spectrum paints or equivalent approved make . Rate shall include surface preparation, with two coats of primer and 2 coats of approved Texture Paint followed by two coats of silicon based clear coat for excellent protection and weatherability and contrast grooves as per manufacturer specification with necessary staging,scaffolding etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge..

Sqm.

645

45

Sqm.

8058

46

Providing and applying External texture paint of approved colour and Spray coat bubble (1018) texture of Spectrum paints or equivalent approved make . Rate shall include surface preparation, with two coats of primer and 2 coats of approved Texture Paint followed by two coats of silicon based clear coat for excellent protection and weatherability and contrast grooves as per manufacturer specification with necessary staging,scaffolding etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge..

Sqm.

8058

47

Providing and applying External Emulsion paint of approved colour of Compo Silicon W55 of SKKAKEN or equivalent make. Rate shall include surface preparation, with two coats of primer followed by 2 coats of silicon based approved emulsion paint for excellent protection and weatherability as per manufacturer specification with necessary staging,scaffolding etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.. Total of Internal & External Finishes Works

Sqm.

4096

48

WATERPROOFING WORKS Treatment to side wall, base slab of Lift pit from exterior surface covering the following sequence of operations :

Providing and applying 3 coats of crystalline waterproofing slurry containing highly active, deep penetrative, reactive catalysts and shall have a mix density of 2.0 kg/litre.. The product shall be applied in 3 coats one over the other at a time gap of 4 to 6 hours depending on the climatic conditions, including curing of the same for at least 5 days fog spraying water. Rate is inclusive of material and labour. Providing Covings/Chamfers at junction of slab and wall with 75mm X 75 mm fillet with cement sand mortar 1:2 mixed with polymer modifier of styrene-butadiene co-polymer latex liquid, produced from styrene and butadiene by high pressure emulsion polymerisation @ 5 L per bag cement. The product shall have minimum butadiene content of 40% by weight. Protective Plaster: The coated surface should be protected with 1:3CM admixed with lignosulphonate polymer based, waterproofing cum plasticing liquid integral waterproofer at a dosage of 100 ml per 50 kg of cement and shall comply with IS: 26452003. Treat the construction joints wherever necessary as per below item specification. Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, Shuttering etc.as complete with all respects complying with relevant manufacturer's specification as directed by the Engineer-in-charge. Treatment to side wall,base slab of UG sump from exterior surface covering the following sequence of operations : Providing and applying 3 coats of of crystalline waterproofing slurry containing highly active, deep penetrative, reactive catalysts and shall have a mix density of 2.0 kg/litre. The product shall be applied in 3 coats one over the other at a time gap of 4 to 6 hours depending on the climatic conditions, including curing of the same for at least 5 days fog spraying water. Providing Covings/Chamfers at junction of slab and wall with 75mm X 75 mm fillet with cement sand mortar 1:2 mixed with polymer modifier of styrene-butadiene co-polymer latex liquid, produced from styrene and butadiene by high pressure emulsion polymerisation @ 5 L per bag cement. The product shall have minimum butadiene content of 40% by weight. Protective Plaster: The coated surface should be protected with 1:3CM admixed with lignosulphonate polymer based, waterproofing cum plasticing liquid integral waterproofer at a dosage of 100 ml per 50 kg of cement and shall comply with IS: 26452003. Treat the construction joints wherever necessary as per below item specification. Sqm. 233

49

50

Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, Shuttering etc.as complete with all respects complying with relevant manufacturer's specification as directed by the Engineer-in-charge. Treatment for STP tanks covering the following sequence of operation : The STP tanks has to be protected with High build, pitch extended epoxy coating which shall be formulated to resist exposure to accelerated weathering test as per ASTM D4587 and shall not exhibit any flaking or blistering. It shall be a 100% solids, solvent free, tough abrasion resistant protective coating used over pile caps. The product shall exhibit excellent bond strength with the substrate at least exceeding 2.5 MPa, when tested as per ASTM D4541. The product shall be formulated to have high build thickness exceeding 150 microns per coat on average and shall be applied to achieve overall thickness of 300 microns in two coats. Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, Shuttering etc.as complete with all respects complying with relevant manufacturer's specification as directed by the Engineer-in-charge. Treatment to side wall,base slab of OH Tank from exterior surface covering the following sequence of operations : Providing and applying 3 coats of a two component reactive polymer composite. The product shall be applied in minimum three coats to achieve total DFT of 2 mm. The product shall resist 7 bars pressure when tested as per DIN 1048 at 2mm DFT. The cured coating shall have the following diffusion co-effiecient. Carbon dioxide 4.21x107 cm2/s Oxygen 7.60x10-6 cm2/s Chloride ion 1.04x107 cm2/s. Rate is inclusive if material and labour. Providing Covings/Chamfers at junction of slab and wall with 75mm X 75 mm fillet with cement sand mortar 1:2 mixed with polymer modifier of styrene-butadiene copolymer latex liquid, produced from styrene and butadiene by high pressure emulsion polymerisation @ 5 L per bag cement. The product shall have minimum butadiene content of 40% by weight.

Sqm.

1919

Sqm.

1194

51

Protective Plaster: The coated surface should be protected with 1:3CM admixed with lignosulphonate polymer based, waterproofing cum plasticing liquid integral waterproofer at a dosage of 100 ml per 50 kg of cement and shall comply with IS: 2645-2003. Treat the construction joints wherever necessary as per below item specification.Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, Shuttering etc.as complete with all respects complying with relevant manufacturer's specification as directed by the Engineer-in-charge. 52 Treatment to sunken slab and its walls covering the following sequence of operations Providing and applying 3 coats of a two component reactive polymer composite. The product shall be applied in minimum three coats to achieve total DFT of 2 mm. The product shall resist 7 bars pressure when tested as per DIN 1048 at 2mm DFT. The cured coating shall have the following diffusion co-effiecient.Carbon dioxide 4.21x107 cm2/sOxygen 7.60x10-6 cm2/sChloride ion 1.04x107 cm2/s.Rate is inclusive if material and labour. Providing Covings/Chamfers at junction of slab and wall with 75mm X 75 mm fillet with cement sand mortar 1:2 mixed with polymer modifier of styrene-butadiene co-polymer latex liquid, produced from styrene and butadiene by high pressure emulsion polymerisation @ 5 L per bag cement. The product shall have minimum butadiene content of 40% by weight. Protective Plaster: The coated surface should be protected with 1:3CM admixed with lignosulphonate polymer based, waterproofing cum plasticing liquid integral waterproofer at a dosage of 100 ml per 50 kg of cement and shall comply with IS: 26452003. Treat the construction joints wherever necessary as per below item specification.( Note: Wall upto 1 M ht ) Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, Shuttering etc.as complete with all respects complying with relevant manufacturer's specification as directed by the Engineer-in-charge. Water proofing treatment over RCC roof slab laid to slope in terrace and gutter slab with Thermal Insulation covering the following sequence of operation and specifications:

Sqm.

607

Sqm.

2396

53

a) SURFACE PREPARATION: The roof slab laid in slope / gutter slab shall be thoroughly cleaned by removing the debris and dust, to receive the water proofing treatment. The cleaning and preparation of the substrate to which the asphalt-modified polyurethane based membrane system is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application of the primer.

b) Waterproofing Membrane: Providing and applying liquid, cold-applied elastomeric waterproofing membrane system a single component moisture curing, asphaltmodified polyurethane based coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric, seamless waterproof membrane applied in 1 or 2 coats to a total DFT of 1.20 mm thick, having an elongation capacity of over 600%(ASTM D 412) and with solid content more than 85% applied on the RCC surface including priming (if required), crack filling, grouting, tie rod filling, coving, ponding etc complete. It shall resist bacterial attack and many acids, alkalis and salts. It shall have a yield of 0.61-0.74 m2/L at 1.1 1.4mm dry thickness SEPARATION LAYER: Providing and laying a separation layer of non-woven polypropylene geo-textile of 200 gsm over the entire surface of insulation board.

c) INSULATION BOARD: Supplying and installation of Expanded polystyrene board for thermal insulation on the terrace of approved make. The insulation board shall be shape moulded and the insulation board shall avoid thermal bridging and have Tongue & groove arrangement for fixing. The board shall have a K-value of 0.032 W/mK and Water Absorption of (% vol) : <0.05% (by total immersion) as per BS EN 12087.The board shall be free from CFC, HCFC and HFC. The board shall be self extinguishing and shall have HF1 rating as per UL94 Test standard. The Actual area covered would be used for measurement. Refer technical data sheet for details.

d) SEPARATION LAYER: Providing and laying a separation layer of non-woven polypropylene geo-textile of 200 gsm over the entire surface of insulation board.

e) SLOPE/PROTECTION SCREED:Providing and laying light-weight site batched trowel finished EPS concrete using selective grade of EPS beads with a density of 12-18 kg/m3, on the geotextile separation layer as in Item-3. The mix shall offer Thermal conductivity of 0.23 0.26 W/m-ok,Comp strength (28 days) of 30-60 kg/cm2.Dry density of 750-950 kg/m3. The mix shall have a water cement ratio of 0.28-0.32 and the hyper-plasticiser range of admixture shall have 1 2 % dosage by weight of cement. The slope built-up cum protection layer shall be laid with a slope gradient of 1:100 (Rate considered for 100mm thickness). It shall be laid to the required level and finish as directed including curing by ponding for a minimum of 7 days. The mix proportion shall be preapproved by Engineer-in-charge. Refer data sheet of THERMOCRETE for mix proportion.

f) FINISHING/WEARING LAYER: Providing and laying China mosaic finish as the final exposed layer of the floor complete as directed. The bedding mortar shall be cementitious polymer modified tile adhesive capable to maintain adhesion under submerged conditions. The product shall have BS 5980 Type 1 standards compliance. It shall have a fresh wet density of 2.1 kg / litre and have 0.18 water/powder ratio, by weight. Immediately after setting of the tiles, rake joints & clean to a uniform depth corresponding to the thickness of the tile. All the ceramic tile joints shall be grouted using, crack resistant, cementitious, water resistant joint grout. The joint grout shall be formulated to maintain water powder ratio of 0.33 by weight and shall comply with BS 5980. Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, supply and adding water proofing chemicals at the specified proportion as per manufacturer's specifications, all materials, wastages, conveyance, tools and plants, mixing device and gauge, shuttering and also include for conducting leakage test at terrace by storing water on the terrace for about 25 mm depth continuously for a period of 7 days etc.as complete with all respect complying with relevant manufacturer specification as directed by the Engineer-in-charge. 54 Water proofing treatment over RCC roof slab laid to slope in terrace and gutter slab without Insulation covering the following sequence of operation and specifications: Sqm. 2605

a) SURFACE PREPARATION: The roof slab laid in slope / gutter slab shall be thoroughly cleaned by removing the debris and dust, to receive the water proofing treatment.The cleaning and preparation of the substrate to which the asphalt-modified polyurethane waterproofing membrane is applied must be carried out thoroughly to leave a sound base for the application. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application of the primer. b) Waterproofing Membrane: Providing and applying liquid, cold-applied elastomeric waterproofing membrane system a single component moisture curing, asphaltmodified polyurethane based coating that cures by reaction with atmospheric moisture to form a tough but flexible waterproofing membrane. It is elastomeric, seamless waterproof membrane applied in 1 or 2 coats to a total DFT of 1.20 mm thick, having an elongation capacity of over 600%(ASTM D 412) and with solid content more than 85% applied on the RCC surface including priming (if required), crack filling, grouting, tie rod filling, coving, ponding etc complete. It shall resist bacterial attack and many acids, alkalis and salts. It shall have a yield of 0.61-0.74 m2/L at 1.1 1.4mm dry thickness SEPARATION LAYER: Providing and laying a separation layer of non-woven polypropylene geo-textile of 200 gsm over the entire surface of insulation board.

c) SEPARATION LAYER: Providing and laying a separation layer of non-woven polypropylene geo-textile of 200 gsm over the entire surface of insulation board. d) Providing and laying light-weight site batched trowel finished EPS concrete using selective grade of EPS beads with a density of 12-18 kg/m3, on the geotextile separation layer as in Item-3. The mix shall offer Thermal conductivity of 0.23 0.26 W/m-ok,Comp strength (28 days) of 30-60 kg/cm2.Dry density of 750-950 kg/m3. The mix shall have a water cement ratio of 0.28-0.32 and the hyper-plasticiser range of admixture shall have 1 2 % dosage by weight of cement. The slope built-up cum protection layer shall be laid with a slope gradient of 1:100 (Rate considered for 100mm thickness). It shall be laid to the required level and finish as directed including curing by ponding for a minimum of 7 days. The mix proportion shall be pre-approved by Engineer-in-charge. Refer data sheet of THERMOCRETE for mix proportion.

e) FINISHING/WEARING LAYER: Providing and laying China mosaic finish as the final exposed layer of the floor complete as directed. The bedding mortar shall be cementitious polymer modified tile adhesive capable to maintain adhesion under submerged conditions. The product shall have BS 5980 Type 1 standards compliance. It shall have a fresh wet density of 2.1 kg / litre and have 0.18 water/powder ratio, by weight. Immediately after setting of the tiles, rake joints & clean to a uniform depth corresponding to the thickness of the tile. All the ceramic tile joints shall be grouted using, crack resistant, cementitious, water resistant joint grout. The joint grout shall be formulated to maintain water powder ratio of 0.33 by weight and shall comply with BS 5980.

Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, supply and adding water proofing chemicals at the specified proportion as per manufacturer's specifications, all materials, wastages, conveyance, tools and plants, mixing device and gauge, shuttering and also include for conducting leakage test at terrace by storing water on the terrace for about 25 mm depth continuously for a period of 7 days etc.as complete with all respect complying with relevant manufacturer specification as directed by the Engineer-in-charge. 55 Providing and laying brickbat coba in CM 1:4( one of cement & four of brickjelly) using well burnt half bricks / bats of 20mm size brickjelly for using toilets and other specified areas including ramming, curing etc.. all complete as directed by Engineer-v

Sqm.

2398

Cum

746

56

Providing chemical injection in the form of pressure grouting to the base slab of Lift pit,retaining walls of lift pit,underground sump and STP from interior surfaces works at any depth, height and level by Drilling 12mm dia holes with percussive drilling machine at areas with honeycombs and at weak zones in the concrete in a staggered pattern at to a depth of 50mm and fixing PVC nozzle of 10mm dia in place using quick setting compound Masterseal 505 of approved maket.Pressure grouting cement slurry mixed with shrinkage compensating additive Flowcable 50, at 250 gms per bag of cement, using hand operated pressure grouting pump with a pressure of 2 to 3 kg/sq.cm through the nozzles by starting from one nozzle and stopping when the grout starts coming out from adjacent nozzle or getting rejected from the same nozzle and similarly carrying out grouting operation in all the nozzles as per approved manufacturer specifications in all the points including the cost of chemical, labour for carrying grouting operations etc.. as complete. Rate shall include for preparation of surface, de-watering, drilling holes, using pneumatic hammer for fixing of PVC nozzles to the required depth, grouting admixture and finally cutting the projected nozzles and sealing of the PVC nozzles after injection operation is over with approved equivalent admixed with cement, finishing, curing, etc., as per manufacturers specification. Rate shall include for preparation of surface by mechanical upgrading to remove all loose mortar and laitance, oil, grease etc. and washing the surface with water to get neat surface, dewatering, finishing, curing, scaffolding, waterproofing chemicals, wastage, conveyance, tools and plants, mixing device and gauge, shuttering, Nozzles etc. complete as per manufacturer's specification and as directed by the Engineer-in-charge. Sqm. 3113

Total of Waterproofing Works 57 MISCELLANEOUS WORKS Providing, supplying and spraying/spreading the Fire sealing in shaft chequered plate for pipe outlets,trays,cables,openings of required dia.outlets using penetration seals of approved make inclusing necessary mechanical equipments,tools and tackles etc complete.cost to include cotton pads,sealing of joints using self sealing, non shrink cement penetration seals / grouts of approved makes either single or double component with necessary formwork, staging, tools, etc., complete with minimum of 30 mm depth for two hours fire rating.Hilti or Promat or Equivalent make are approved by the Engineer-in-charge. Sqm. 498

58

Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'HILTI' or equivalent make diamond drilling machine with tolerance for any type of inserts, anchor fasteners etc. Rate shall include for all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding application of necessary chemical / foil (HAV) as per manufactures specification with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete, as directed by the Engineer-in-charge. 75 to 100 mm dia to the following depth: 150 mm Depth 200 mm Depth 250 mm Depth 300 mm Depth 100 to 150 mm dia to the following depth: 150 mm Depth 200 mm Depth 250 mm Depth 300 mm Depth 150 to 225 mm dia to the following depth: 150 mm Depth 200 mm Depth 250 mm Depth 300 mm Depth 225 to 300 mm dia to the following depth: 150 mm Depth 200 mm Depth 250 mm Depth 300 mm Depth 300 to 450 mm dia to the following depth: 150 mm Depth 200 mm Depth 250 mm Depth 300 mm Depth Supplying and fixing poly-propelene rungs of 25 mm square bar of size 260 x 170 mm for access way including anchorage in walls to a minimum depth of 100 mm with C.C 1:2:4 (one cement,two fine aggregate and four coarse aggregate) etc. complete and as directed by the Engineerin-charge.( Duct ,Shafts & UG sump,Over Head Tank and wherever necessary) Note: Rungs to be fixed before concreting and necessary provision to be made in the shuttering.etc complete, as directed by the Engineer-incharge.

a i ii iii iv b i ii iii iv c i ii iii iv d i ii iii iv e i ii iii iv 59

Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos Nos No's

10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 100

60

TRANSPLANTING Transplanting of Tree fouling in the proposed building layout in ONGC project to the suitable place as per the Architectual drawing and as directed by the Engineer in charge,including trimming the tree branches excavating earth around the tree to required length,width and depth to remove the tree with required roots to transport the tree to new location as per the drawing inside the site and digging the new pit,torequired size to transplant the tree including cost for earth work excavation,trimming the tree branches to required size,removing and shifting the tree using machinaries and equipments to new location as per the drawing and as directed by the Engineed in charge, digging required size of pit to transplant the tree, refilling the pit after planting the tree with river sand,poring water and providing manure etc., and maintaining the tree planter for a further period of Twenty Four months including watering etc.,complete as directed,includes for all operations as discribed and nothing extra shall be paid for Rain Tree,Coconut Tree. Etc., CUTTING, AND REMOVING Cutting the dead trees and trees which are not able to transplant etc., in to pieces including uprooting the trees,by excavating earth to required size and levelling the ground after removal of the trees and cutting pieces of trees stacked in site as directed by the engineer in charge. Note: Prior permission from the forest department shall be obtained before cutting. Rain Tree,Neem tree etc., Clearing light / scrub jungle and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared etc all complete as directed by the engineer in charge. Credit to Client towards the dismantling and taking away from the site of existing old dilapidated Asbestos Cement (AC) sheet roof buildings having the following dimensions. The rate shall inclusive of dismantling the superstructure with any type to any thickness, masonry, walls, lintels, beams, plastering, flooring, wooden/steel trusses, rafters, pulins, AC roof sheeting, any Reinforcement Concrete members, ,joineries like doors, windows, ventilators, internal & external electrical wiring with fixtures, water supply and sanitary installations and the like as exists at site including substructures to the required full depth as directed. The rate shall include disposing of unserviceable materials away from the site, including clearing the site neatly etc. all complete as directed by the engineer in charge. Note: Prior approval shall be obtained from the concerned department. AC sheet roof building of size 7.20 x 4.50m Nos 30

61

62

Nos Sqm.

32 30000

63

18

No.

64

18

AC sheet roof building of size 6.40 x 6.40m AC sheet roof building of size 7.60 x 7.60m AC sheet roof building of size 21.50 x 9.70m Credit to Client towards the dismantling and taking away from the site of existing reinforced cement concrete (RCC) roof buildings having the following dimensions. The rate shall inclusive of dismantling the superstructure with any type to any thickness, masonry, walls, lintels, beams, columns, plastering, flooring, roof slab, ,joineries like doors, windows, ventilators, internal & external electrical wiring with fixtures, water supply and sanitary installations and the like as exists at site including substructures to the required full depth as directed. The rate shall include disposing of unserviceable materials away from the site, including clearing the site neatly etc. all complete as directed by the engineer in charge. Note: Prior approval shall be obtained from the concerned department Community center building 17.50 x 9.50m Dismantling of Brick Work / Stone work / Solid Block Work including plastering/pointing to any depth and width, at all levels below & above Ground Level including removal of debris, disposing the same away from the site, loading and unloading, making the surface good etc. complete. Rate shall include for dismantling of Brick Work / Solid Block Work including plastring/pointing, removal of debris by manual / mechanical means with necessary tools and plants, scaffolding, water and power charges, cleaning the surface, preparation of surface. Rate shall include for stacking the serviceable materials and disposing the unserviceable materials/debris away from the site by mechanical means including loading, unloading clearing the site etc. complete as directed by the Engineer-incharge. Providing and laying of light weight concrete fill on structural slab using Hemalite/Vermiculite cement based composition having physical elasticity , chemical inertness, firm adhesion, fire resistance with thermal / acoustic insulation properties, anti-corrosion, anticondensation, etc in the required proportion to get the desired density, mixing, transportation, placing, compacting and finishing to the required level with necessary side supports, equipments and its density is 600kg/cum wherever necessary areas to be fill as directed by the Engineer-in-charge.etc as complete with all respects complying with relevant standarad specification as directed by the Engineer-in-charge.

No. No. No.

1 1 1

65

18

Nos. Cum

1 141

66

Cum

39

67

Supplying and fixing 40mm dia. and 150mm or more long G.I. pipe spouts in sun shades including painting two coats of first quality synthetic enamel paint of approved make and tint over one coat of primer as complete in all respects complying with relevant standard specification and as directed by the Engineer-in-charge. Supplying and fixing Ductile Iron manhole cover and frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge. 600X600 mm Medium duty DI manhole cover not less than 65kgs 600X600 mm Heavy duty DI manhole cover not less than 90kgs Providing Plinth protection with PCC 1:3:6 (One cement, three fine aggregate and six coarse aggregate) 50mm thick using coarse graded aggregate of 20 mm and downsize, top finished smooth while wet and laid with a nominal slope, over a sand bed of 75 mm thick including necessary excavation wherever, necessary form work etc . The end slab shall have 115 mm thick brick retaining walls with CM 1:4 (one cement and four fine aggregate) at the edge 300 mm high. The exposed faces of wall shall be plastered with cement mortar 1:5 - 15 mm thick. The effective separation of panels not exceeding 10 sqm in plan by making grooves or by using glass or other metals strips etc.and also including for providing necessary form work, excavation, refilling, consolidation and compaction of filled earth, plastering, pointing, curing and reinforcement as complete in all respects complying with relevant standard specification and as directed by the Engineer-incharge. Providing and laying in position the RCC humepipes(NP2) of approved quality and make including collars,. necessary Excavation, PCC 1:2:4 supports, Sand cushion of 150mm on all sides, Refilling with earth, Compaction and making good the level, alignment etc.,complete as directed by the Engineer-incharge. 300 mm dia

No's

50

68

a b 69

No's No's Sqm.

10 49 872

70

RMT

410

71

Supplying and fixing single skin bare Galvalume metal sheet Roof cladding for car shed at all heights using 0.47 mm TCT 550 Mpa profiled Galvalume steel (Aluminium zinc alloy coating 150 gms / sqm total of both sides) sheet including necessary structural steel frame work consisting of all vertical / horizontal members,purlins, and all other fixtures etc. The rate should inclusive of cutting, fabricating, erection at all levels, providing openings, all fixtures and fixing accessories such as self drilling, self tapping fasteners, butyl or acrylic sealants, profiled foam /neoprene fillers etc. including necessary civil works to erect the vertcal struts, two coats of PU painting over one coat of zinc chromate primer, cost of all materials, steel members, purlins, labour,scaffolding, wastage, tools, tackles, equipment,transportation, preparation of shop drawings etc. all complete as per specifications, drawings and as directed by the Engineer-incharge. Supplying, fabricating, erecting, testing and commissioning of Cylinder Manifold system,centralized Gas Bank with individual connection to all kitchens using reticulated LPG pipeline with (Schedule 40) 25 mm dia C class MS pipe and appropriate 16mm / 20mm razor composite pipe to the required length as per the site condition up to the connection point inside the kitchen in the C&D type residential block. The rate should include the cost of gas meter, inlet, outlet fittings, all other necessary accessories like butterfly valves, pressure gauges, gas filters, nonreturn valves, flexible hoses, composite brass fittings etc..as requied to complete the work in all respects and testing and commissioning all as per IS6044 Part-1 2000 specification and as per the approved firm. The rate shall include all necessary materials and accessories, civil works, painting,scaffolding, core cutting wherever necessary, and making good condition, power etc.. as directed.

Sqm.

1323

72

Job (One Job).

66

Total of Miscellaneous Works ROAD & PAVEMENT WORKS Concrete Road Preparation & sectioning the area road surface and compacting with 10 ton power roller including forming camber and gradients watering and rolling to reach required density as complete.as directed by the Engineerin-charge.

73

Sqm.

11808

74

Construction of 300mm thk Granular subbase (GSB) by providing coarse graded material 53mm to 4.75 mm ,spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as complete in all respects complying with relevant standard IRC,MORTH and MOST Specifications and as directed by the Engineer-incharge. Providing, Laying, Spreading and compacting 45 mm to 4.75 mm graded stone aggragate of 200mm thk wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant,carriage of mixed material by tipper to site,laying in uniform layers with paver in subbase / sub course on well prepared surface and compacting with vibratory riller to achieve the desired density,as complete in all respects complying with relevanat standard MOST specification,as directed by the Engineer-in-charge. Providing and laying 100mm thk. Plain cement concrete1:3:6 (One cement, three fine aggregate and six coarse aggregate) by using coarse graded aggregate of 25 mm and down size for levelling course in road and pavement areas wherever necessary (as per drawing) including laying in layers of thickness not exceeding 100mm and in alternative bays not exceeding 40 sqm as directed including form work wherever necessary and well compacted etc. as complete in all respects complying with relevant standard specification as directed by the Engineer-in-charge Providing and laying controlled cement concrete mix of M20 grade to a thickness of 150 mm for roads and pavements laid to required slope and camber in panels confirming to IRC standard. Rate shall include for providing IRC Weldmesh of size 100x100 - 12 Gauge - one layers confirming to IS: 1566 & IS: 4948 or equivalent BS,necessary formwork, shuttering,props, bracing and wedges, sufficiently strong & stable, providing 25 mm wide expansion joints and construction joints & closing the joints using polyurethene sealant "VULKEM" - 202 PU from Supreme or approved equivalent make etc.complete, as directed by the Engineer-in-charge . Kerb and Pavement works

Cum

3543

75

Cum

2362

76

Cum

1181

77

Cum

1771

78

Providing and fixing vacuum wetpress concrete precast Splay kerb to shape by using reinforced cement concrete M20 grade road kerbs of size 150X375X600 mm made to shape using 20 mm down size Coarse graded Basalt aggregate including form work and nominal reinforcement of Fe 415 grade, 12 mm dia at 150 c/c with 8 mm dia stirrups at 150 mm c/c fixing in cement concrete 1:3:6 nominal mix (one cement,three sand and six hard stone jelly) including all materials and labour components,laying,finishing,curing and the pointing exposed faces with C.M 1:3 (one cement and three fine sand) and colour washing with acrylic emulsion over a coat of primer etc..as complete in all respects complying with relevant standard specifications and as directed by the Engineer-incharge. 79 Supplying and laying Shotblasted Flexi Pavers of approved design - 65 mm thick, total weight shall be 25 kg approximately per one set or 1.94 Sft of flexi pavers contains five pieces including transportation of the blocks to the site ,preparation of surface,supplying and filling with dry river sand to 50 mm thick, leveling and compacting with plate vibrator and laying of the flexi paver blocks with sand binding and final compaction with plate vibrator of 3 tone capacity finishing the surface including cutting of blocks at the edges including all labour and materials etc as complete in all respects complying with relevant standard specification, as directed by the Engineer-incharge. (For Pathway) 3000 Providing thermoplastic painting for car park and road line and arrow marks with 100mm wide involving cleaning the surface free of dirt and loose particles applying one coat of primer and applying one layer of thermoplastic paint wih drop on glass beads. Rate shall include for all materials & labour components etc., as complete all respects complying with relevant IRC specifications, as directed by the Engineer-incharge. Total of Road & Pavement Works 81 Tennis Court Preparation, Formation & Construction of Tennis court as per the ITF (International Tennis Federation) specification having the following sequence of works: Earth work excavation to the required depth as shown in the drawing by manual/mechanical including levelling the base, dressing of sides and ramming with all leads and lifts, shoring, strutting and bailing out of water if required.The rate shall include disposing the excavated earth away from the site or dumping & levelling inside the campus as directed.

RMT

3280

Sqm.

2792

80

RMT

1808

ii

Filling and levelling of good earth brought from outside and to be laid in layers of 150mm thick and compacted with 10tonne power vibrating roller including forming required gradient (1:10),watering and rolling to reach the required density etc., as directed. Providing Anti-termite treatment over the prepared base surface using approved chemical in appropriate proportion to avoid the growth of weeds and termites, as directed. Construction of 200mm thk Granular subbase (GSB) by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density, as directed. Providing, Laying, Spreading and compacting graded stone aggragate of 150mm thk wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant,carriage of mixed material by tipper to site, laying in uniform layers over the granular sub-base and compacting with vibratory roller to achieve the desired density,as directed. Providing and laying Dense Bitumen Macadam for compacted thickness of 30mm using 20mm down size metals mixed with 80/100 grade hot bitument at 4% of weight and mix from central hot mix plant and laid by paver finishing and compacting with vibratory roller. Rate shall be include with all plants and machineries, cost, conveyance and incidential charges, as directed. Providing and laying of 30 mm compacted thick asphalt concrete (HOT MIX) over the dense bituminous macadam base with IRC standard 12mm and down coarse graded basalt aggregate and binder content by using 80/100 grade Bitumen, adopting suitable job mix formula as directed, including surface preparation, heating and mixing in central hot mix plant to the required temperature, cost and conveyance of all materials to site, laying the mix to the required temperature, specified lines, grades, gradient and cross section using mechanical paver finisher and consolidation by 10 tonne power roller to get the required density including all labour charges, hire and fuel charges for all tools and plants employed etc., as directed.

iii

iv

vi

vii

viii

Providing and laying of 20 mm compacted thick asphalt concrete (HOT MIX) over the dense bituminous macadam base with IRC standard 6mm and down coarse graded basalt aggregate and binder content by using 80/100 grade Bitumen, adopting suitable job mix formula as directed, including surface preparation, heating and mixing in central hot mix plant to the required temperature, cost and conveyance of all materials to site, laying the mix to the required temperature, specified lines, grades, gradient and cross section using mechanical paver finisher and consolidation by 10 tonne power roller to get the required density including all labour charges, hire and fuel charges for all tools and plants employed etc., as directed. Providing and laying tack coats over the prepared surface of WMM,DBM,30mm thk asphalt as per the MORTH specification, as directed. Providing and laying seal coat (Type-B) over the prepared surface of 20mm thk asphalt as per the MORTH specification, as directed. Providing and laying ITF certified Ultra cushion nine layer system Synthetic surface over the 20mm thick Asphalt Base, it shall be made ready by cleaning with Water and is checked for any Bird Baths. Minor Patch work if required shall be carried out done with acrylic resurfacer. The ratio of mixing of resurfacer for Patch work is 3 (acrylic resurfacer): 1 (Silica Sand) : 1 (Water) The rate shall include for supply and installation of a) Resurfacer to make an underlay for the cushion surface comprising of Mixing ratio is 3:1.25 (Silica Sand) : 1( water). b) Five Cushion layers above the resurfacer comprising of Mixing ratio of 4 (cushion) : 1 Water. c) First & Second Layer of Colour shall be provided and installed on top of the Cushion layer. Mixing Ratio is 5 (acrylic Colour) : 3 (sand) : 2 (Water)d) Third layer of Colour is poured on top of the first layers of Colour. Mixing Ratio is 2:1 (Water). e) Supply and installing Line Marking.All Acrylic is poured onto the surface and spread with a Squeejie. In addition to the above sequence of works, the quoted rates shall inclusive of power, water, CIF values of synthetic surface, transportation, installation, all duties and taxes, etc.,as complete in all respects complying with relevant standard specification .as directed by the Engineer-Incharge. Providing and constructing of Edge wall/Retaining RCC wall in cement concrete M25 grade, around the perimeter of the tennis court including necessary form work, reinforcement, base PCC, etc., all as shown in the drawing, as directed by the Engineer-incharge. Providing and constructing of Saucer Drain with gratings along the longer end of the tennis court, all as shown in the drawings.

ix

xi

xii

Sqm.

674

82

RMT

110

83

RMT

37

84

Supplying, fabricating and fixing in position of PVC coated 10 gauge chain link Wire mesh fencing fixed along with GI Pole pipes measuring 3.0m high from toe wall and one metre insert the toe wall around the perimeter of the tennis court (as per drawing) at all levels with the provision of door opening of the required size & profile consisting of channels, angles, runners, insert plates, flats and sag rods with necessary sleeves, bolts and nuts,pipes,embedding the poles in concrete etc.. including cutting, straightening, welding as per standards for connections including consumables etc.as complete. Rate shall include preparation of surface, applying two coats of Zinc chromate/Phosphate primer and two coats of synthetic enamel paint of approved make etc.. as directed by the Engineer-incharge. Supplying,fabricating and Fixing ITF certified Tennis Net of size 42X 3 feet fixed to the MS net post of size 80x80X3mm as shown in the drawing and as per approved make and specification including ITF certified Water Removing Roller as per approved make and specification.etc., as directed by the Engineer-incharge. Total of Tennis Court

Sqm.

279

85

No.

86

Golf Fencing Supply and installation of High strength weather proof polyolefin Golf Fencing Net of approved brand using 1.5mm twisted and 2mm mesh square to height of 20m along with the 100mm dia MS hollow pipe erected at equal intervals including plates,nutbolts,cleats, ladder, 8mm dia PVC coated Steel wire rope for net erection etc..as per the specification. The rate shall be including of all necessary civil works, Structural works, epoxy painting works, power, electricity,erection machneries etc.. as directed by the Engineer-incharge. Golf Fencing Total of Golf Fencing RMT 140

87

Garbage Chute Supplying, Fabricating and commissioning of Centralized Garbage chute of approved make (SS430 X 1.2mm thk), 450mm dia ( Ground to Eighteenth Floor ) .with a provision of autoclosing intake down at every floor level and a fire rated door (90 minutes rating-UL label 10B) at the discharged end, with required garbage trolley, etc., complete as per BS 1703:2005,IS6924-2001& NBC 2005 specification. The rate shall include all installation components, scaffolding for erection, required structural brackets with anchor fasteners, Sprinklers for fire and cleaning, necessary vent with bird netting etc.. as directed by the Engineer-incharge. Total of Garbage Chute

No.

SANITARY FIXTURES & FITTINGS: (PROVIDING & INSTALLATION) Note: Detail of Sanitary fixture are for the information of the Contractor, however model / makes of all sanitary fixture shall be selected by Engineer-Incharge and the same shall be binding for execution No additional all fixing cost shall be paid for change in type of sanitary fixture or fitting. Provision of extension piece for final connection of CP fitting shall be supplied and installed by the contractor accordingly (as required) Providing & Fixing, testing and commissioning of white vitreous China wall mounting type European water closet (RS346467460) including providing & fixing C.P. bolts, nuts (C8152), bakelite / poly propylene seat & cover (RA80P467001) with C.P. hinges & rubber buffers, C.P. brass screw, washer with all accessories. Including cutting & making good the walls, floors, slab wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA / Equal approved make, Model:GIRALDAWALL HUNG WC WITH SOFT CLOSE SEAT COVER) Providing & Fixing, testing and commissioning of white vitreous China wall mounting type European water closet (RS346247000) including providing & fixing C.P. bolts, nuts (C8152), bakelite / poly propylene seat & cover (RA8012A2004) with C.P. hinges & rubber buffers, C.P. brass screw, washer with all accessories. Including cutting & making good the walls, floors, slab wherever required as directed by the Engineer-incharge. (Make :- ROCA/ Equal approved make, Model NEW MERIDIAN WALL HUNG WC WITH SOFT CLOSE SEAT COVER- )

88

102

Nos.

191

89

102

Nos.

90

102

Providing & Fixing, testing and commissioning of white vitreous China wall mounting type European water closet (RS346477000) including providing & fixing C.P. bolts, nuts (C8152), bakelite / poly propylene seat & cover (RA8012A2004) with C.P. hinges & rubber buffers, C.P. brass screw, washer with all accessories. Including cutting & making good the walls, floors, slab wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Gap wallhung with soft close seat cover )

Nos.

91

102

Providing & Fixing, testing and commissioning of white vitreous China wall mounting type European water closet (C0255) including providing & fixing C.P. bolts, nuts (C8152), bakelite / poly propylene seat & cover (RA8012A2004) with C.P. hinges & rubber buffers, C.P. brass screw, washer with all accessories. Including cutting & making good the walls, floors, slab wherever required and as complete, as directed by Engineer-Incharge(Make :ROCA/ Equal approved make, Model:- Indus Walvit Pan with seat cover ) Providing&Fixing, testing and commissioning of white vitreous China Indian type(orissa patern) water closet. Including cutting & making good the walls, floors, slab wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model & No.Orissa Pan 500mm - C0111) Providing, fixing, testing and commissioning of exposed plastic low level cistern for WC, with dual flush facility complete with all necessary fittings, flush pipes & accessories including all supports and making good and as complete, as directed by Engineer-Incharge (Make :ROCA/ Equal approved make, Model & No.Slimline Economy Dual flush - C8109) Providing&Fixing, testing & commissioning of concealed type cistern with dual flush facility comprising of actuator button facia assembly and Push plat including brass / SS screws and washer complete, providing protection cover over cistern, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:- Slendra concealed cistern 80 mm , No:RA890031410, Chrome Push plate round knob No:RA8900450B1 ) Health Faucet Providing&Fixing, testing & commissioning of ABS Rinsing spray with regulator of approved quality with plastic flexible pipe 1.5 m long, wall hook complete as required and as complete, as directed by EngineerIncharge (Make :- Jaquar/ Equal approved make, Model:Health faucet No:- ALD-563) Providing&Fixing, testing & commissioning of ABS Rinsing spray with regulator of approved quality with plastic flexible pipe 1.5 m long, wall hook complete as required and as complete, as directed by EngineerIncharge (Make :- Jaquar/ Equal approved make, Model:Health faucet No:- ALD-577) Wash basin

Nos.

92

102

Nos.

93

102

Nos.

94

102

Nos.

205

95

102

Nos.

197

96

102

Nos.

97

Providing&Fixing first quality white vitreous china oval / round / square wash basin (RS327465000) (size as per architectural drawing) for counter top mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :- Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA// Equal approved make , Model:- Giralda countertop basin 600*475 mm, ) Providing&Fixing first quality white vitreous china oval / round / square wash basin (RS327240000) (size as per architectural drawing) for counter top mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :- Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:- Meridian N wall hung wash basin 700*460, ) Providing&Fixing first quality white vitreous china oval / round / square wash basin (RS327115000) (size as per architectural drawing) for under counter mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :-Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA// Equal approved make, Model:- Diverta UC washbasin 620*440mm) Providing&Fixing first quality white vitreous china oval / round / square wash basin (C0471) (size as per architectural drawing) for counter top mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :- Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:- Indus basin (500*400mm),

Nos.

228

98

Nos.

99

Nos.

22

100

Nos.

101

Providing&Fixing first quality white vitreous china oval / round / square wash basin (RS327874000) (size as per architectural drawing) for counter top mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :- Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:- kalahari vanity Basin 650*450mm) Providing&Fixing first quality white vitreous china oval / round / square wash basin (RS32751A000) (size as per architectural drawing) for counter top mounting, 32 mm CP brass waste coupling and CP brass cast bottle trap (Make :- Jaquar/ Equal approved make, Model:- ALD-709 & ALD-769 ) and pipe to wall with CP brass flange and rubber adopter for waste connection complete including filling gap between counter and wash basin with approved type poly sulphide sealant, cutting and making good the walls wherever required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:-Dama Senso Compacto square washbasin 650*470mm ) Basin mixer Providing&Fixing, testing and commissioning of Basin mixer with Aerator and wall flange (as required) and making good as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- OPL 15051B) Providing&Fixing, testing and commissioning of Basin mixer with Aerator and wall flange as required and making good as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- KUB 35051B). Urinal Providing&Fixing, testing and commissioning of white viterous china urinal including providing & fixing CI / MS bracket (duly painted with 2 coats of paints over a coat of primer), including CP brass waste with dome type grating, complete with all accessories and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make,Model:-Integrated EFS - Smart AC with Power Source, C8195)

Nos.

16

102

Nos.

103

Nos.

268

104

Nos.

105

Nos.

106

Providing, fixing, testing and commissioning of white viterous china large flat back / half stall urinal supported by CI / MS bracket (duly painted with 2 coats of paints over a coat of primer), including CP brass waste with dome type grating, CP cast brass bottle trap with extension piece, wall flanges complete with all accessories and as complete, as directed by Engineer-Incharge ((Make :- ROCA/ Equal approved make,Model:-Euret urinal 425*797 mm back inlet, RS35945F000) Providing, fixing, testing and commissioning of automatic flushing systems for urinal to ensure pre-flush & flushing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting / chasing and making good, as required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make,Model:-Urinal sensor powered by 220 volts - AC, RT5X9415E00) Providing & Fixing, testing, and commissioning of Acrylic bath tub (Vythos drop-in bathtub 1700*800mm) completely leveled, including waste overflow drain set (RF506403010) , chain plug, legs, grouting of legs etc with cement concrete all complete as required and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:- RW247701000) Providing & Fixing Deck mount bath tub mixer with spout and telephonic hand shower and as complete, as directed by Engineer-Incharge.((Make :- ROCA/ Equal approved make, Model:- AMURA 4 HOLE HIGHNECK TUB FILLER +H.SWR, RT527306580) Shower area Providing&Fixing Concealed bath shower divertor, Single lever divertor exposed parts, spout, shower arm, overhead shower and wall flanges complete and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:-ALD - 065, KUB 35065K, SPJ- 35429, SHA - 479 L 450, and OHS-1823 ). Providing&Fixing Concealed bath shower divertor, Single lever divertor exposed parts, spout, shower arm, overhead shower and wall flanges complete and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:-ALD - 065, OPL 15065K, SPJ- 429, SHA - 483 L 450, and OHS-1779).

Nos.

107

Nos.

15

108

Nos.

109

Nos.

110

Nos.

111

Nos.

174

112

Providing&Fixing Thermostatic shower column complete and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Neo Basic Thermostatic shower cloumn, Model No. RP2H035800 ), Providing&Fixing Thermostatic shower column complete and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Neos II Basic Thermostatic shower cloumn, Model No. RP2H0348000 ), Providing&Fixing Overhead shower with short / long arm and wall flange complete and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make,Model: Single flow overhead showerT9901A1), Providing&Fixing push type liquid soap dispenser with PVC rawl plug & C.P. brass screw complete as required and as complete, as directed by Engineer-Incharge(Make :ROCA/ Equal approved make,) Towel Rail & Ring Providing & fixing C.P. brass towel rail with C.P. brass wall brackets & C.P brass screws complete as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- ACN-1111n). Providing & fixing C.P. brass towel ring with C.P. brass wall brackets & C.P brass screws complete as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:-ACN-1121 BN). Providing & fixing C.P. brass towel with C.P. brass wall brackets & C.P brass screws complete as required and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:- QUA - 61723). Providing & fixing C.P. brass Double coat hook with PVC rawl plug & C.P. brass screw complete as required and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:- AKB - 35761). Providing&Fixing C.P brass toilet paper holder with PVC rawl plug & C.P. brass screw complete as required and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:- ACN - 1155N). Providing&Fixing C.P brass toilet paper holder with PVC rawl plug & C.P. brass screw complete as required and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:- ACN - 1153N).

Nos.

113

Nos.

114

Nos.

115

Nos.

10

116

Nos.

183

117

Nos.

96

118

Nos.

119

Nos.

69

120

Nos.

181

121

Nos.

24

122

Providing&Fixing, testing and commissioning of Kitchen sink including providing & fixing C.I./M.S. Brackets (duly painted with 2 coats of paint over a coat of primer) C.P. cast brass bottle trap with extension piece, rubber adaptor, wall flange, union, C.P. brass chainrubber plug & making good and as complete, as directed by EngineerIncharge (Make-Nirali / Equal approved make, Model No. C853199, C854399) Stainless steel sink without drain board. Supplying and fixing 600 x 450 mm Reflextion mirror of Parryware make or approved equivalent with necessary screws, nuts and washer and as complete, as directed by Engineer-Incharge Model:No:C 8608 - Parryware make or approved equivalent make. Providing&Fixing, testing and commissioning of C.P. brass wall / counter mounted Sink Cock with Regular Swinging Casted Spout with Wall Flange complete as required and making good and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- FLR-5347N). Providing&Fixing solid state, no touch operting, fully hygienic hand drier of approved shade with single/double blower, with time delay, summer & winter control, music while drying, volume ON/OFF controls including providing necessary brackets, cable from drier to Plug, Plug top key and lock etc, complete as directed by the Engineer-incharge.(Make-Eronics / Equal approved make, Model No. - EH06S ) Providing&Fixing, testing and commissioning of C.P Copper connection 450 mm long including nuts and washers and making connection to fixtures and fittings complete as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- ALD-805B). Providing & Fixing, testing and commissioning of C.P. brass angle valve with C.P. wall flange, Nut and Washer etc. complete as required and as complete, as directed by Engineer-Incharge (Make :- Jaquar/ Equal approved make, Model:- FLR-5053N). Providing, fixing, testing and commissioning of 15 mm dia C.P. brass long body bib cock with C.P. wall flange of approved quality and making good as required and as complete, as directed by Engineer-Incharge (Make :Jaquar/ Equal approved make, Model:- CON-107KN). Providing and fixing Heavy class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement & suitable for waste and FD and as complete, as directed by EngineerIncharge(Make :- Chilly- India King or equal approved make,) No. No. 20 194

123

124

No.

115

125

No.

10

126

No.

389

127

No.

598

128

No.

22

129

No.

568

130

Providing&Fixing, testing and commissioning of Adjustable Type of Washbasin 65x35 with one pair of mounting brackets, EWC and cistern complete with fittings and seat cover, one no hinged rail, 76 cm and five no grab rails 60 cm and as complete, as directed by Engineer-Incharge (Make :- ROCA/ Equal approved make, Model:-(Carron PP Closet with Antimicrobial seat cover - C0250 + C8094), (Hand Rails 600 - C8154), (Hinged Arms - C8153), (Plastic cistern - C8157), Indus basin (500*400mm - C0471), (Pillar Cock with Aerator T1602A1)) Total of 'Sanitary Fixtures & Fittings COLD WATER SUPPLY Providing and fixing in position Class 'C' GI pipe work for all pump suction / discharge line with common header complete with all fittings like elbow, tee, reducer, flange, union etc. conforming to IS:1239 (Part 1) for pipes and IS : 1879 (Part 1 to 10) for fittings including fixing in wall / ceiling / floor level, supported by galvanized clamps, hangers, vertical pipe support etc. and as complete, as directed by Engineer-Incharge. 80 mm dia 100 mm dia 150 mm dia Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes confirming to IS:15778/2007 with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 23 Deg C)for pipes from 1/2 Inch to 2 Inch. Schedule 40 Pipe to be used from 2-1/2 Inch to 6 Inch Schedule 40 Pipe to be used . Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846. ASTM F441 with only CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings.

No.

B 131

a b c 132

RMT RMT RMT

10 20 10

a b

Cost shall be inclusive of (a)Making maximum of 7.5 x 7.5 cm chase in wall and floors for the pipe, making good the same by using 1:3:6 cement mortar over the wire mesh and providing protection to embedded pipes and fittings (in wall chase) by wrapping two layers of 400 micron polythene sheet including proper overlaps on joints complete as required.and as complete, as directed by Engineer-Incharge. 3/4" dia (20 mm) 1" dia (25 mm)

RMT RMT

3945 4

133

a b c d e f 134

a b c d e 135

a b 136

a b 137

a b

Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes as above. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, fastener, hangers etc, as per specification. Exposed pipes to be painted of legends with direction arrow. GI pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end and as complete, as directed by Engineer-Incharge. 3/4" dia (20 mm) 1" dia (25 mm) 1.1/4: dia (32 mm) 1.5" dia (40 mm) 2" dia (50 mm) 2-1/2" dia (65 mm) Providing & fixing male/ female screwed end full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated ball & teflon seat tested to a pressure 15 Kg / sqcm with (threaded joints) complete as required and as complete, as directed by Engineer-Incharge 20 mm dia 25 mm dia 32 mm dia 40 mm dia 50 mm dia Providing and fixing C.I. Butterfly valve (Body : Grey Cast Iron, shaft : SS, Disc : SG Iron (nickel plated), Liner : HT - EPDM/Nylon) of approved make with flange, washer, nuts & bolts and PN 16 pressure rating including rubber gasket & painting complete.and as directed by Engineer-Incharge. 65 mm dia 80 mm dia Providing & fixing C.I. wafer type check valve of rating PN 16 including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required and as complete, as directed by Engineer-Incharge 65 mm dia 80 mm dia Providing & fixing dual flanged C.I. `Y' Strainer with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required and as complete, as directed by Engineer-Incharge 65 mm dia 80 mm dia

RMT RMT RMT RMT RMT RMT

4 2735 2756 1278 170 2

No. No. No. No. No.

2 830 68 33 25

No. No.

1 2

No. No.

1 2

No. No.

1 2

138

Providing and fixing in position of approved quality high pressure rated Gun Metal Float Valve with copper ball float and brass rods of required length suitable for test pressure of not less than 15 Kg/sqcm of the following sizes and as complete, as directed by Engineer-Incharge. 25 mm dia 32 mm dia 40 mm dia Providing and fixing pressure reducing station for cold water supply comprising of 2 Nos Gun Metal ball valves on inlet & outlet & 1 no. globe valve for by-pass 1 No pressure reducing valve with flanged/ screwed connection, 1 No. `Y' strainer, 2 Nos Pressure gauge on inlet & outlet, and 1 No. 15 mm dia safety valve. The complete system is tested to a pressure not less than 15 Kg/Sq.cm and suitable to reduce the pressure upto 2 Kg/Sq.cm) Including necessary pipe & fittings; i.e. flanges/ unions, nuts, bolts and washers complete as required and as complete, as directed by EngineerIncharge 25 mm dia (Brass Housing - PRV) 32 mm dia (Brass Housing - PRV) 40 mm dia (Brass Housing - PRV) Providing, fixing , testing and commissioning water metre with direct reading dial in KL with all necessary fitting such as threaded pieces, unions pressure gauge, isolation cock, flanges piece for future removal, flanges / unions complete with all necessary testing charges and obtaining test certificates from municipal authorities and as complete, as directed by Engineer-Incharge., on following size pipe lines (1 no. strainer shall be provided at inlet & outlet and cost shall be inclusive for the same). No. No. No. 5 7 10

a b c 139

a b c 140

No. No. No.

6 74 27

a b 141

50 mm dia (CI) 65 mm dia (CI) Providing & fixing Auto Air vent for cold water supply risers, suitable for pressure not less than 15 Kg/Sq.cm. 25 mm dia Constructing brick masonary chamber (for housing valves,metres etc.) of brick work with bricks of 230X115X75mm class 50 with cement mortar 1:5 (1 cement:5 fine sand) plastering internal face & (with a floating coat of neat cement) cement mortar 1:3 (1 cement: 3 fine sand and rough plaster on outer face. R.C.C top slab with medium duty D.I. manhole cover and frame of 600x600 mm (weight : 60 KG). Including excavation, dewatering, refilling, watering, ramming and removing the surplus excavated material complete as required and as complete, as directed by Engineer-Incharge (All sizes are clear internal sizes). Size 600 x 600 x 600 mm deep

No. No.

1 2

a 142

No.

22

31

No.

143

144

Providing & fixing of LOFT Tank (Make: Sintex, Model No:IWS 30.01,Cap-300 lts)(Location :Toilet).as complete, as directed by Engineer-Incharge Providing & fixing of SS Tank ( 304 grade ) For RO Water supply (Cap-500 lts) (Location : Terrace).as complete, as directed by Engineer-Incharge Total of Cold Water Supply INTERNAL DRAINAGE : (RAIN,SOIL, WASTE & VENT) Providing, fixing, jointing, testing and commissioning of UPVC pipe conforming to I S 4985 with 6kg/sq.cm. waste pipe from fixture to floor trap cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces (plain or door) & vent cowl. Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated. As complete, as directed by Engineer-Incharge. 40 mm dia 50 mm dia Providing, fixing, jointing, testing and commissioning of UPVC pipe confirming to I S 4985 with 6kg/sq.cm cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces and material and making good the same complete as required and as directed by Engineer-Incharge Cost shall be inclusive of providing protection to pipe all round / haunches as per specification. (Running at toilet sunken,shaft, Rain water down take, data cabling & balcony) 75 mm dia 110 mm dia 160 mm dia Providing, fixing, jointing, testing and commissioning of UPVC pipe confirming to IS : 13592, and confirming to IS : 4985 (Pipe Class II -6 kg / sq.cm) cut to required lengths including all necessary fittings and specials such as bends, junctions offsets, access pieces (plain or door) & vent cowl. Fixing at wall / ceiling level supported by G.I. clamps, hangers etc. duly epoxy coated and as complete, as directed by Engineer-Incharge(Location for Shaft )

No.

202

No.

C 145

a b 146

RMT RMT

596 103

a b c 147

RMT RMT RMT

2311 4843 1760

a b c d

63 mm dia 75 mm dia 110 mm dia 160 mm dia

RMT RMT RMT RMT

656 200 1162 786

148

Providing, fixing, jointing, testing and commissioning UPVC (Class III) Rain water down take pipe conforming to IS:4985 cut to required lengths including all necessary fittings and specials. Fixing at wall/ceiling level supported by galvanized steel clamps & hangers etc. Making proper connection with cement solvent joint as per BIS / manufacturer. Cutting, chases / holes in floors / walls / slab. and as complete, as directed by EngineerIncharge 75 mm dia 110 mm dia 160 mm dia Supplying and fixing of approved make UPVC multi inlet floor trap with110mm dia inlet & 75mm dia outlet and it is fixed in Sunken slab .and as complete, as directed by Engineer-Incharge. Supplying and fixing in position of Custom Made P trap of the following sizes from UPVC 6kg/cm2 pipe by maintaing 50mm water seal including providing necessary support and as per Specification as complete, as directed by Engineer-Incharge. 110mm dia inlet & 110mm dia outlet Providing & fixing rain water `Khurras' size 450x450 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. Including Heavy duty CI/MS grating as per drawing complete as required and as directed by Engineer-Incharge Total of Internal Drainage :(Rain,Soil,Waste & Vent) EXTERNAL SEWAGE / DRAINAGE/WATER SUPPLY: STORM WATER RMT RMT RMT Nos. 737 103 970 635

a b c 149

150

151

No. No.

4 28

152

External Water supply Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes confirming to IS:15778/2007 with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 23 Deg C)for pipes from 1/2 Inch to 2 Inch. Schedule 40 Pipe to be used from 2-1/2 Inch to 6 Inch Schedule 40 Pipe to be used . Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846. ASTM F441 with only CPVC solvent cement conforming to ASTM F-493. All termination points for installation of faucets shall have brass termination fittings. Installation shall be to as per Technical Manual of manufacturer of pipes & fittings.

a b c d e f g 153

Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes as above. Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, fastener, hangers etc, as per specification. Exposed pipes to be painted of legends with direction arrow. GI pipe sleeves suitable higher size shall be provided wherever the pipes are crossing the fire rated walls / floors slab and sealing the sleeves with glass wool in between and fire sealant compound at either end. As complete, as directed by Engineer-Incharge. External Water supply 1" dia (25 mm) 1.1/4" dia (32 mm) 1.1/2" dia (40 mm) 2" dia (50 mm) 2-1/2" dia (65 mm) 3" dia (80 mm) 4" dia (100 mm) Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 6 Kg / Sq.cm for drainage system cut to required length. Pipe to be laid below ground level in trenches upto required depth including excavation in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round / haunches as per specification and also as complete, as directed by Engineer-Incharge (For sewer and Sullage line) 160 mm dia 200 mm dia Providing, fixing, jointing and testing in position the following UPVC pipes confirming to IS:4985 of 6 Kg / Sq.cm for drainage system cut to required length. Pipe to be laid below ground level in trenches upto required depth including excavation in all kind of soil (hard rock), dewatering, refilling, watering, ramming and removing the surplus excavated material and making good the same complete as required. Cost shall be inclusive of providing protection to pipe all round / haunches as per specification and also as complete, as directed by Engineer-Incharge (For storm water line) 200 mm dia Providing and fixing square mouth cast iron gully trap complete in brick masonry 300 x 300 mm chamber of standard detail with first class bricks and water tight double seal CI cover with frame of 300 x 300 mm internal size. The weight of cover and frame to be not less than 10 Kg as per standard design and also as complete, as directed by Engineer-Incharge

RMT RMT RMT RMT RMT RMT RMT

252 401 355 420 343 343 10

a b 154

RMT RMT

604 367

RMT

606

155

156

(Note : Cost shall include excavation dewatering and watering proofing of chambers as directed at site) 300 x 300 mm chamber with 150 x 100 mm size GULLEY trap Designing and constructing brick masonry inspection chamber of the following sizes in brick work of class 75 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face, proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD - 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same complete as required.

Set

33

a b c 157

Contractor shall submit the structural design and drawings for the approval of Engineer-incharge prior to execution. 900 x 800 mm size(UP TO 900mm) 1200 x 900 mm size(UP TO 2.4M) 1500mm Dia Circular(2.4 to 3.0m Depth) Providing & fixing Cast Iron Manhole cover with frame in Cement concrete 1:2:4 (one of cement two of sand and four of hardbroken stone jally) finished neatly etc..as complete, as directed by Engineer-Incharge.- For inspection chamber 600 x 600 mm, Heavy Duty (B-125), Wt 115 kg Designing and constructing brick masonry Rain water collection chamber for fire protection valve chamber and for data cabling of the following sizes in brick work size 230x115x75mm of class 50 in cement mortar 1:5 (1 cement:5 fine sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm. nominal size) embeded with frame for manhole, RCC foundation slab. 1:2:4 mix (1 cement : 2 coarse sand:4 graded stone aggregate 40 mm nominal size) both inside and outside of plastering 12 mm thick with cement motar 1:3 (1 cement : 3 coarse sand) with a floating coat of neat cement on inside face,

No. No. No.

38 19 4

a 158

No.

61

proper water proofing to ensure no ground water seepage in the manhole, Poly propylene (conforming to ASTMD 4101) foot rests (meeting the 224 kg load requirement as per IS 5455) at 300 mm spacing, benching and making channels with 1:2:4 cement concrete neatly finished, including necessary centering and shuttering, reinforcement, excavation, in all kind of soil, dewatering, refilling, watering, ramming and removing the surplus excavated earth, making good the same all complete as directed by Engineer-incharge. a b 159 600 x 600 x 600 mm size 900 x 800 mm size x 900 mm size Providing & fixing Ductile Iron Manhole cover with frame in Cement concrete 1:2:4 (one of cement two of sand and four of hardbroken stone jally) finished neatly etc..as complete, as directed by Engineer-Incharge.- For Rain water collection chamber 600 x 600 mm, Medium Duty (B-125), Wt 115 kg Total of 'External Sewage/Storm Water Drainage/Water Supply E 160 CIVIL WORKS / MISCELLANEOUS ITEMS: Providing and fixing 600 mm long MS hot dip galvanized PUDDLE FLANGES fabricated out of 6 mm thick MS plates of suitable size and IS:1239 heavy class pipes properly fixed in walls & top slab of tanks. The entire fittings shall be hot dipped galvanized after fabrication. Length shall be minimum 600 mm or wall thickness plus 200 mm on either side (which ever is more). etc. as complete, as directed by Engineer-Incharge. 50 mm dia (flanged ends) 80 mm dia (flanged ends) 100 mm dia (flanged ends) 150 mm dia (flanged ends) 200 mm dia (flanged ends) Providing and fixing electronic type level indicator for water tanks mounting in panel with the following features, level display, alarm when water level is low or high, full range from one level to four level display and manual reset for alarm etc. with electrical wiring conduit supports from wall & ceiling probs and all other accessories etc as complete, as directed by EngineerIncharge. Total of Civil Works/Miscellaneous Items WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT Hydropneumatic System: Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System As Follows: In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) No. No. No. No. No. No. 62 49 48 9 2 6 No. No. 34 171

No.

205

a b c d e 161

162

a.

(Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. Nos. of Pumps : 3 (2W +1S) Water Flow Rate : 4.09 LPS each Head : 108 M Purpose :- Cold water supply Electric control panel with change over swich, relays, electrical wiring, cabling from panel to pumps, level controller complete with all accessories as per manufacturer specification. Complete (Skid mounted wall mounted / floor mounted) electrical control panel comprising of all accessories such as PLCs, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor) Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc complete. Set of accessories such as pressure switches, pressure transducers, inter connecting power and control cabling etc. complete Accessories like NRVs, isolating valves, SS-304 (nonMagnetic) suction and delivery header, pressure gauge, MS base frame (Synthetic enamel painted over a coat of primer) Hydropneumatic System as described above Supply, installation, testing and commissioning of terrace Booster pump comprising of the following: Horizontal mono-block centrifugal pump, suitable for operation on 415 volts 6%, 3 phase, 50 HZ A.C supply. The pump casing shall be CI, shaft shall be CS & impeller / shaft sleeve / casing wearing ring shall be bronze. The system shall be complete with necessary pressure gauge with gun metal shut off cock on delivery side. (The pump should meet the condition and shall be gotten approved by the Local fire Authority). Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ AC supply for the above pump with speed of 2900 R.P.M. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by others) complete with Antivibration arrangement of cushy foot mounting. Nos. of Pumps : 2 (1W +1S) Water Flow Rate : 1.0 LPS each Set 5

b.

c.

d.

e.

f.

Set

163

Head : 25 M Purpose :- Terrace booster pump Submersiable Pumps Submersiable Centrifugal Non-clog Drainage Pumps Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc.Cost shall be inclusive of auto pumping arrangement. (IW +1S) Flow rate : 3.3 LPS Head : 25 Mts Solid Handling : 10-12 MM Location : Rain water storage sump-1 &2 Purpose : Rain water transfer to Fire water tank. MOC : CI Body, impeller and SS Shaft Flow rate : 3.3 LPS Head : 25Mts Solid Handling : 10-12 MM Location: Plumbing Plant Room MOC : SS body SS Impeller & Shaft Total of Water Supply,Drainage,Pumps & Equipment Set 2

164

165

Set

G 166

ELECTRICAL INSTALLATION FOR PLUMBING Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel T sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables (in accordance to specification) with earthing from panel to each motor / equyipment. PLUMBING SYSTEM

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel T sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. Quoted rates shall inclusive of cables, cable trays, control cabling, cabling, earthing (in accordance to specification) with earthing from panel to each motor / equipment.

MCC 1 (Plumbing Panel) Incoming 100 amps TPN MCCB with the following accessories: a. 0-500 volts 96 x 96 mm square voltmeter with selector switch protected by 2 amps TP MCB. 1 Set b. 0-200 amps 96 x 96 mm square ammeter with selector switch and 200/5 amps 10 VA CL:1 CTs. 1 Set c. Phase indicating lamps protected by 2 amp SP MCB 3 Sets Bus Bar 125 amps TPN (25 KA) aluminium bus bar with heat shrinkable insulation sleeves. Outgoings a. 1 No. 32 amps TPN MCCB outgoing feeder to RO Water Hydro-pneumatic. b. 1 No. 63 amps TPN MCCB outgoing feeder to Domestic Water Hydro-pneumatic. c. 2 No. 32 amps TPN MCCB for 3 HP DOL starter and outgoing feeder to Water treatment pump motor (including 1nos. standby). Each compartment shall contain auto / manual selector swtich and indicating / pushbutton lamps with MCB for ON / OFF / TRIP of motor. d. 2 No. 32 amps TPN MCCB for 2 HP DOL starter and outgoing feeder to plumbing plant room drain pump (including 1nos. standby). Each compartment shall contain auto / manual selector swtich and indicating / pushbutton lamps with MCB for ON / OFF / TRIP of motor.

e. 4 No. 32 amps TPN MCCB for 5 HP DOL starter and outgoing feeder to Storm water transfer pump (including 1nos. standby). Each compartment shall contain auto / manual selector swtich and indicating / pushbutton lamps with MCB for ON / OFF / TRIP of motor. (Note : Starter to be located at near storm water sump. so seprate encloser required for starter with all nessacery items.) f. Spare MCCBs of following capacities: i. 32 amps TPN MPCBs 2 Nos. iii. 63 amps TPN MPCBs 1 Nos. Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also be included. Notes : a. All MCCBs shall be of 25 KA breaking capacity and suitable for motor duty application. b. Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS c. Provision shall be made to ensure system protection from dry running of the pump MCC - 1 (Plumbing panel) as described above. Total of Electrical Installation for Plumbing 167 Water Treatment Plant-90,000Liter/Day Providing, Installing, testing and commissioning of SS vertical centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber. Pump shall be provided with mechanical seal. The pump shall be suitable for auto / manual operation. The installation shall be complete with all necessary ancillaries & accessories including base plate complete as required. (1Working + 1Standby). Flow rate : 11250 LPH each Head : 30 Mts Required for : Raw water treatment for Feed pump Providing, Fixing, Testing & Commissioning of vertical MSEP filter with adequate dirt holding capacity. Fabricated from MS sheet as per manufacturer's specifications complete with initial charge filter media including painting inside with two coats of non toxic epoxy and with one coat of zinc chromate two coats of synthetic enamel paint outside. Including concrete foundation with cement plaster complete as required. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Complete with frontal piping (heavy) and butterfly valves designed on 1.50 m / sec velocity. Pressure Sand Filter for Domestic Water services. Filtration Rate 15000L/Sqm/Hr Working pressure 3 Kg/Sq.cm

Set

Capacity : 11250 LPH Activated Carbon Filter Filtration Rate 15000L/Sqm/Hr Working pressure 3 Kg/Sq.cm Capacity : 11250 LPH Providing, Fixing, Testing & Commissioning of MSEP water softening plant (suitable for 3 Kg/Sqcm working pressure) complete with initial charge with T-40 NA Resin, multiport valve with built in ejector for controlling all operations), regeneration system and HDPE tank, pressure gauge at inlet, outlet and back wash (each with isolation cock), valves, fittings and water hardness testing kit & associated works. Softener shall be suitable for the following duty: Raw water hardness 800 Mg/L Treated water harness 100 Mg/L Regeneration Period 8 Hrs. Capacity : 11250 LPH Providing, Installing, testing and commissioning of dosing system (for domestic water treatment plant) consisting of one HDPE tank of 100 liters capacity with a positive displacement diaphragm dosing pump having variable flow rate of 0-4 lph. The motor shall be suitable for operation at 240 V/Single phase/50 Hz. Supply. The pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall be speed & stroke control Asia LMI / equivalent make. The cost shall be inclusive of providing salt for the testing and operation of system before handover to the owner. Supply, installation, testing & commissioning of High Flow UV system for tertiary water treatment. The UV chamber shall be internally & externally electro polished with double side flange, drain part & probe bar. The unit shall use quartz glass technology for superior UV transmission and specialized high intensity UV lamp rated for 16000 hour operation. The UV dosage shall be greater than 30,000 uW-Sec / sq.cm system to be complete with monitoring units. Unit flow : 90 Cum / Day ( 11.25 KL/hr) Providing, Fixing, Testing & Commissioning of pressure switch for water pumps to start/stop the pump at set pressure. Including wiring, cabling from pump to panel & all other accessories as required to operate the system automatically.

Providing, Fixing, Testing & Commissioning of the following heavy class GI pipes conforming to IS:1239 cut to required lengths including all necessary fittings (conforming to IS:1879) and specials such as bends, tees, unions, reducers, flanges & plugs etc. fixing at wall / ceiling level supported by clamps, hangers etc, (to be galvanized after fabrication) cutting hole in wall / floor / slab and making good the same good with cement concrete 1:2:4 / fire sealant complete as required. Painting two coats of Synthetic enamel paint of approved shade on pipes and supports as per pipe color code over a coat of primer. Including painting of legends with direction arrow as per the approval of the EngineerIncharge. Providing, Installation, testing and commissioning of tanker inlet connection complete with 80 mm dia GI inlet piping, hose inlet connection, MS cabinet enclosure (epoxy painted after fabrication), pad locking arrangement, inlet flexible hose complete with all necessary arrangement. Providing, Fixing, Testing & Commissioning of butterfly valve (Body : Grey Cast Iron, Shaft : SS, Disc : SG Iron (Rilson coated), Liner : HT - EPDM) (up to 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 15 Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. Providing, Fixing, Testing & Commissioning of CI wafer type check valve tested to a pressure of 15 Kg/sqcm. Including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required. Providing, Fixing, Testing & Commissioning of CI `Y' Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required (on pump suction). Providing, Fixing, Testing & Commissioning of on line turbine type flowmetre with preamplifier electronic flowmetre mounted in plumbing plant room electrical control panel with the following features. Monitoring the total flow, Flow rate, high low arm batching and blending etc. Including electrical wiring from preamplifier to microprocessor based flowmetre. Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete with all respect. Providing, Fixing, Testing & Commissioning of Heavy class header complete for pump suction / discharge manifold comprising of expansion bellows, flanges, unions, check nuts, tee elbow etc. including all flanged connections as per drawing / site requirement. Supports from wall, floor and ceiling etc. Including dead end flanged connection complete as required.

Rate shall include all the above works / specification as directed by Engineer-incharge. Total of WTP 168 RO TREATMENT Plant Capacity of 2000 Liter/Day Supply, installation, testing and commissioning of 500 liters/day @ 4hr per day capacity of RO plant and suitable Filter Feed pump, Pressure Sand Filter, Activated Carbon Filter, antiscalant dosing system, reverse osmosis system sikd mounted, high pressure pump, membrane pressure vessel, Ro membrane with CIP system , ph correction dosing system, Pressure Gauge, Flowmetre, Piping, Electrical panel and cable etc... Note :- 1. Outlet water from the RO plant meeting the drinking water quality requirement with chemical parameters in acceptable limits as per the : IS 10500, 1991, 2. and also all pumps are provide ( 1 work +1 standby ). Hydropneumatic System: Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System As Follows: In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) (Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. Nos. of Pumps : 2 (IW +1S) Water Flow Rate : 0.23 LPS each Head : 108 M Purpose :- RO water supply Total of RO Treatment 169 Sewage Treatment Plant Capacity of 2, 50,000Litres/Day, Design, supplying, installing, testing & commissioning of Sewage Treatment Plant (excluding excavation, back filling & disposal of surplus earth Civil construction work) for the following duty: Nature of effluent - Domestic Sewage from residential toilets & kitchens. Daily average flow - 225 Kld pH - 7.5 8.5 BOD5 - 250 400 Mg/L S. Solids - 150 200 Mg/L COD - 300 600 Mg/L Oil & Grease - 50 Mg / L Effluent discharge standard after treatment

Set

Set

pH - 6.0 8.5 BOD5 - Less than 5 Mg/L S. Solids - Less than 5 Mg/L COD - Less than 30 Mg/L Oil & Grease - Less than 5 Mg/L Sewage treatment plant shall include the following items: Screen Chamber Sewage equalization tank/sump Aerobic MBBR Reactor Floating Media Secondary Clarifier tank Flocculator Tertiary Clarifier Tank Sludge holding tank Air Blowers, Pumps & equipment Screw Pump & Filter Press Piping, valves etc Electrical Panel & Cabling Flushing / Irrigation water storage tank Common plant room adjacent to STP. Multigrade sand filters and Activated carbon filters. Supply, installation, testing & commissioning of 2 Nos Stainless Steel Coarse & Fine Perforated Screen with suitable lifting arrangement (size 600 mm wide x 1000 mm high approx) Supply of MS hot dip galvanized puddle flanges in accordance to BS:10 table D as required to be provided (in the structural slab and wall) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil contractor in accordance to the Civil GA drawing (to be prepared by the STP contractor) at the required levels & position; under the supervision of the STP contractor Supply of plastic manhole step/foot rest (@ 300 mm c/C) with polypropylene compound injection molded around 12 mm dia (Fe-415) steel reinforcing bar. Provision of the foot rest is envisaged in various tanks/ components of the STP for the purpose of accessibility. The installation of the foot rest shall be done by the civil contractor as per civil GA drawing Supply, installation, testing & commissioning of CI medium duty rectangular manhole cover with frame for the feasibility of access in the tank Size : 600 x 600 (175 kg) Supply of vent pipes of 100 mm dia with mosquito proof grating suitable for the ventilation purpose of the various tanks

Supply, installation, testing & commissioning of electronic type level controller for automatic operation of the system with high/low level alarm complete with auxillary NO/NC contacts for Raw Sewage Pumps Contractor shall ensure submission of detailed GA drawings (Plan & Section), P & I diagram, schematic diagram for the above mentioned component and additional component if so required for the complete working of the STP and got it approved by the EngineerIncharge. Supply, installation, testing & commissioning of non clogging type pumps capable of handling solids upto 38 mm having CI casing & impeller complete with all accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation cock, level controller (with wiring) to control the level of sump automatically. Pumps shall have following duty: Submersible Sump Pumps (1W + 1S) Flow rate (each) = 11.25 cum / hr Head = 10 Mtr Plant room sump pump with CI body & CI impeller pump (1W + 1S) Flow rate (each) = 5 cum / hr Head = 15 Mtr (Solid handling size for this pump shall be 8 to 15 mm). Cost shall be inclusive of PVC flexible Hose pipe ( for piping submeged in effluent) with PVC/GI piping (for piping non-submerged in effluent) Provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section shall be made by the STP contractor. (If Required) Contractor is requested to submit quote rate for above pumps with CI Casing & SS impeller, material of construction. Air diffusion system shall include the following: Twin lobe rotary air blowers capable of delivering 450 cum/hr. of free air at 0.5 kg.cm2. driven through V belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 10% volts, 3 phase, 50 cycles A/C supply (1W +1S). Blower to be housed in an acoustically treated room such that their operating noise does not exceed 80 DB at 3 mtrs. from the blower enclouser. Air piping shall comprise of pipes droppers/ laterals with GI Header complete with all fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc . Contactor to submit detailed P & I indicating their proposal.

Non clog type air dispersion system . Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. Supply of MBBR media consisting of Virgin PE carrier modules with Surface are not less than 500 M2/M3 Bronze Ball valve and air dispersion grid as required for STP as described above. Note : Air dispersion system shall be provided for Sewage Sump, Aerobic digester cum Thickner & Aeration Tank. Providing and fixing all piping (as described below) and isolation control valves for making the system complete. SS /GI / PVC : Submerged air piping GI : Air piping PVC Piping : Pumped effluent , tank overflow pipe line & Process Piping. GI Heavy : Interconnecting pipe line after delivery header of pump/ filter Designing, supplying, providing, fixing, testing and commissioning of STP as mentioned above. Supplying, installation, testing and commissioning of horizontal sludge recirculation pumps coupled with motor of capacity 10 cum/hr at 10 m head of C.I. Parts and mechanical seal complete with isolation and nonreturn valves. (1working + 1 standby) Capacity : 10 cum/hr Head : 10 M Supplying, installing, testing & commissioning of Horizontal centrifugal filter feed water pumps CI Impeller along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, strainer at suction.Mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia.) for the pump. The pump shall be suitable for 41510% volts 3 phase AC supply (solid handling size for this pump shall be - 5 mm) (1W + 1S). Capacity : 11.25 cum/hr Head : 30 M Supplying, installing, testing and commissioning of centrifugal Horizontal water supply pump C.I Body, CI Impeller with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation valve, strainer at suction. Suction & delivery header (sized at velocity of 1.5m/sec.). Suitable vibration elimination pads of approved design for the pump. The pump shall be suitable for 41510% volts 3 phase AC. Supply. Capacity : 2 LPS (1W + 1S) Head : 50 M

Purpose : Irrigation water transfer pump Note Operation of pump shall be based on level controller proposed to be installed in tank as per site location. The contractor to recheck the Head required for pumps as per site conditions and provide accordingly. Supplying, installing, testing and commissioning of composite MSEP vessel filter with MS frontal piping. Filter shall be suitable for working pressure of 5 kg / cm2 and shall include media, standard fittings like pressure gauges, sampling cock, backwash, rinse drain, vacuum breaker, including multiport valve, &1 no. water flowmetre at outlet (flowmetre shall be approved by dept. of weights & measures). Multigrade pressure sand filter Flow rate : 11..25 cum/hr (1W) Filtration velocity 15000 Ltrs./ Hr./ Sq.m. Activated Carbon Filter Flow rate : 11..25 cum/hr (1W) Filtration velocity 12000 Ltrs./ Hr./ Sq.m. Supply, installation, testing & commissioning of High Flow UV system for tertiary water treatment. The UV chamber shall be internally & externally electro polished with double side flange, drain part & probe bar. The unit shall use quartz glass technology for superior UV transmission and specialized high intensity UV lamp rated for 16000 hour operation. The UV dosage shall be greater than 60,000 uW-Sec / sq.cm system to be complete with monitoring units. Unit flow : 11.25 Cum / hr Supply, installation, testing & commissioning of poly electro type dosing system comprising of 100 ltrs HDPE tank with 0-6 lph electronicmetreing type pump and SS agitator complete with motor. Supply, installation, testing & commissioning of single screw double stage, flanged end, CI body alloy steel screw and rotateing parts, pump to filter press 400 LPH 60 mtr. head complete. Supply, installation, testing & commissioning of Manual closing mechanism filter press comprising of CI body grade FG 20, polypropylene plate with sludge cake holding capacity of 650 ltrs.

Providing, fixing, testing and commissioning watermetre with direct reading dial in KL with all integral parts of gun metal or brass with necessary fitting such as threaded pieces, unions pressure gauge and isolation cock, flanges piece for future removal, flanges / unions complete with all necessary testing charges and obtaining test certificates from municipal authorities, on following size pipe lines (1 no. strainer & 2 nos. pressure gauges shall be provided at inlet & outlet and cost shall be inclusive for the same).

50 mm dia Total of STP Works WATER SUPPLY, DRAINAGE, PUMPS & EQUIPMENT Hydropneumatic System: Supply, Installation, Testing And Commissioning Of Compact Self Contained Skid Mounted Hydropneumatic System As Follows: In-Line, Multisage, centrifugal pumps with SS-304 casing and impeller and SS-316 shaft, CI base & head TEFC motor (with mechanical seal) (Vendor to submit performance curves and technical catalog of the proposed model for review & information) The pump shall be selected for performance at best efficiency point. However, the pump selection shall be suitable for performance with set point @ + 20% of the rated head. Nos. of Pumps : 3(2W+1S) Water Flow Rate : 2.08 LPS each Head : 107 M Purpose :- Flush water supply Approval from pollution board at initial & various other stages of works including preparation of report / drawings as per pollution board requirement arrangement of raw sewage testing & commissioning. Contractor shall include the cost of all chemicals (consumed during testing & commissioning) and the cost of such items of works which are not explicitly mentioned above, but are mendatory to have pollution board approval. (Consent to operate only) Total of Water Supply,Drainage,Pumps & Equipment Works 170 Elecrtical Installation for Sewage Treatment Plant Control Panel for Sewage Treatment Plant

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3 formation with reinforcement of suitable size angle iron, channel T sections irons and/or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanised hardware with zinc passivation shall be used in fabrication of panels.

MCC-1 (STP Motor Control Centre) Incoming 100 amps TPN MCCB with the following accessories: a. 0-500 volts 96 x 96 mm square digital electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set b. 0-100 amps 96 x 96 mm square digital electronic ammeter with selector switch and 100/5 amps 15 VA CL: 1 CTs. 1 Set c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets Bus Bar 125 amps TPN (25 KA) copper bus bar with heat shrinkable insulation sleeves. Outgoing a. 2 Nos. suitable rating MPCB for 2.0 HP direct on line starter and outgoing feeder to EQT sewage transfer pumps motor - Main (including 1nos. standby). Each compartment shall contain auto / manual selector switch and indicating / pushbutton lamps with MCB for ON / OFF / TRIP of motor. b. 2 Nos. 63A MCCB for 10.0 HP Star delta starter nd outgoing feeder to air blowers (including 1 no. standby). Each compartment shall contain auto/manual selector switch and indicating lamps with MCBs for ON/OFF/TRIP' status of motor. c. 2 Nos. suitable rating MPCB for 1.0 HP direct on line starter and outgoing feeders to sludge recirculation pump (including 1 no. standby). Compartment shall contain auto/manual selector switch and indicating lamps with MCBs for ON/OFF/TRIP status of motor.

d. 2 Nos. TPN MPCB for 3.0 HP direct on line starter and outgoing feeders to (1W+1S) filter feed pump. Each compartment shall contain direct operated digital ammeter of 0-63 amps range, auto/manual selector switch and indicating lamps with MCB and ON/OFF/TRIP status of motor f. 1 No. suitable rating MPCB for 1 HP direct on line starter and outgoing feeders to Helical Screw Pump. Compartment shall contain auto/manual selector switch and indicating lamps with MCBs for ON/OFF/TRIP status of motor. g. 1 Nos. 40A TPN MCCB for 6.5 HP direct on line starter (2W+1S) and outgoing feeders to fluhing water supply by hydropnumatic system. Each compartment shall contain C T operated 0-63 amps range digital ammeter with selector switch, auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor h. 2 Nos. TPN MPCB for 5 HP direct on line starter (1W+1S) and outgoing feeders to irrigation pump. Each compartment shall contain C T operated 0-32 amps range digital ammeter with selector switch, auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor e. 2 Nos. TPN MPCB for 1 HP direct on line starter and outgoing feeders to (1W+1S) plant room floor drian pit pump. Each compartment shall contain direct operated digital ammeter of 0-32 amps range, auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor n. Spare of following capacities: i. 32 amps TPN MCCB 2 Nos. ii. 63 amps TPN MCCB 1 Nos. o. Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also included Notes: a. All MCCBs shall be of 25 KA breaking capacity and suitable for motor duty application. b. All motor starter shall be provided with Automatic level controller. c. Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS MCC-1 for Upper Level STP as described above CABLE & CABLE TRAYS Supplying, laying & suitable no.of termination of following 1100 volt grade PVC sheathed aluminum/copper conductor armoured cables as per specification in existing trenches, cable trays, ducts over bed of sand, clamped to wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. 4 core 4 sq. mm copper cable

4 core 6 sq. mm copper cable 3 core 2.5 sq. mm copper cable 3 core 4 sq. mm copper cable Supply and fixing of perforated type GI cable trays with supports, hangers, fastners of the following sizes as per specification. 300 mm x 40 x 40 x 2 mm thick 200 mm x 40 x 40 x 2 mm thick 150 mm x 25 x 25 x 2 mm thick EARTHING Supply and fixing of following bare GI tapes / wires including all necessary fixing accessories and effecting connections as per specifications. 25 x 6 mm thick GI strip. 8 SWG GI wire Total of Electrical Installation for STP Works 171 Solar Hot Water system-capacity - 13000 Liters/day Supplying, fixing, testing & commissioning of black painted copper collector panel (each panel capcity 200 liter / day) housed in aluminum casing with top of glass shall be as per specifications including all required structural support, necessary inter connecting piping, drain point with valve auto air vent valve etc. complete as required. (Note : Civil work to be executed by other agency under requirement of Solar Hot water Heating Contractor. However this vendor to provide details of all such civil requirements & also ensure his supervision during the civil works execution). Solar Water Storage Cum Calorifier Tank : Supply, installation, testing & commissioning of SS 304 horizontal / vertical Solar hot water storage cum calorifier tank (Capacity 1000 Lts) suitable for minimum 8 Kg /Sq.cm working pressure and having SS-304 tube for heat exchange of ____ Kcal/Hr heat transfer capacity, duly mounted by removable type SS-304 flange with gasket, nuts & bolts. Tank shall be provided inlet / outlet, overflow / drain connection with MH cover (550 mm I.D.) pressure relief valves, thermometer at inlet / outlet. All the valves & accessories shall be suitable for an operating pressure as mentioned above. Tank shall be mounted on 450 mm high steel structural supports with access ladder painted with 2 coats of red oxide paint.

Set

Supply, installation, testing & commissioning of SS 304 horizontal / vertical Solar hot water storage cum calorifier tank (Capacity 450Lts) suitable for minimum 8 Kg /Sq.cm working pressure,duly mounted by removable type SS-304 flange with gasket, nuts & bolts. Tank shall be provided inlet / outlet, overflow / drain connection with MH cover (550 mm I.D.) pressure relief valves, thermometer at inlet / outlet. All the valves & accessories shall be suitable for an operating pressure as mentioned above. Tank shall be mounted on 450 mm high steel structural supports with access ladder painted with 2 coats of red oxide paint. Tank shall be insulated as per specification, including 24 gauge aluminium cladding. The flanges shall be of SS 304 with dimensions confirming to AN SI, B 16.5 No. 150. The nozzles shall be SS ERW pipes. (Tank shall be fabricated as per unfired pressure vessel code IS 2825-1969, IS 226 / IS 2062). Hot water mixing tank complete with insulation & MS supporting structure with access ladder duly paint with red oxide. Cold Water inlet Suitable pipe dia with PN 1.0 Butterfly Valve. Cold Water inlet line Suitable pipe dia with Check Valve. inlet / outlet connections for solar system. Suitable pipe dia with PN 1.0 Butterfly Valve. Hot water outlet connection to Mixing tank Suitable pipe dia with PN 16 Butterfly Valve. Spare outlet 50 mm dia PN 16 Butterfly Valve Tank Drain connection 25 mm Ball Valve Temperature sensor at calorifier tank suitable for differential temperature setting shall be made for start / stop of the water recirculation pump. The control / system shall be complete with necessary cabling / wiring along with support. Providing, fixing, jointing and testing in position the following dia of copper pipes confirming to BS2871 (Table X) with ISR, Endex, Endbraze fitting confirming to BS:864 part 2 such as copper tees, crosses, plugs, elbows, reducers, union sleeve pieces etc. Cutting hole in wall / floor / slab and making good the same. Cost shall be inclusive of Fixing/supporting the pipes (& fittings) at wall/floor level supported by galvanized clamps, hangers etc, as per specification. Exposed pipes to be insulated (seprate item) and painting of legends with direction arrow on insulation.

Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) water supply pipes with pipe as per CTS SDR 11 (operating pressure - 7 Bar @ 82 Deg C and 28 Bar @ 23 Deg C)for pipes from 1/2 Inch to 2 Inch. Schedule 80 Pipe to be used from 2-1/2 Inch to 6 Inch. Pipes shall be joined using solvent welded CPVC fittings i.e. Tees, Elbows, Couplers, Unions, Reducers, brushings etc. including transition fittings (connection between CPVC & metal pipe/GI) i.e. Brass Adaptors (both Male & Female threaded) conforming to ASTM D-2846. ASTM F441 with only CPVC solvent cement conforming to ASTM F-493. Cost shall be inclusive of Fixing/supporting the pipes (& fittings) at wall/ceiling level supported by galvanized clamps, hangers etc, as per specification. Exposed pipes to be insulated (seprate item) and painting of legends with direction arrow on insulation.

Providing, fixing, jointing and testing in position the following heavy class (Class C) G.I. pipes for HWS/HWR conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 part 1 to 10) and specials such as bends, tees, unions, reducers, flanges & plugs etc. Threading, jointing, and making proper connections. Cost shall be inclusive of Fixing/supporting the pipes (& fittings) at wall/floor level supported by galvanized clamps, hangers etc, as per specification. Exposed pipes to be insulated (seprate item) and painting of legends with direction arrow on insulation. Providing and fixing nitrle rubber insulation on hot water supply / return pipes. Providing and fixing proprietary polyshield outer mechanical protection ON nitrile rubber insulation comprising of wrapping with poly glass tape helically wound and subsequently applying 2 coats of polyshield material (resin & hardner) as per manufacturers specification and approved by Project Manager / Consultnats. Providing and fixing forged brass ball valves with brass ball / stem, union/flange, washer, nuts & bolts. Rated to temperature of 85 Deg C and tested to a pressure not less than 16 Kg/Sq.cm. Including covering with nitrile rubber insulation having protective coating against mechanical damage as per manufacturers specification (GI boxing to be provided). Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required. Providing and Fixing of Temprature Gauges with isolation valve suitable for system Temprature.

Providing and fixing auto air vent for Hot water supply system suitable for pressure not less than 15 Kg / Sqcm including water expension tank of 100 mm dia. & 400 mm long expension tank complete as requitrd. Providing, installation, testing and commissioning of following insulated pumps suitable for 415 Volts connected with T.E.F.C. induction motor, M.S. channel, base plate with nuts & bolts complete with vibration isolators, isolating valve on suction and discharge, non return valve on discharge, pressure gauges with stop cock and dial type thermometer on suction or discharge, necessary Termination with connecting cable from pump to electrical panel, lugs, earthing wire, cable tray etc. The pump shall have mechanical seal. The pump shall be SS 304 casing, impeller, shaft and CI (Epoxy coated) base (suitable for hot water temperature). Flow - 33 LPM Head - 30 Mtr HEAT PUMP HOT WATER SYSTEM Supplying,fixing, testing and commissioning, Air to water heat pump of with LCD display thermo controller & tank probe .the heat pump outer surface should be mill finished painted alluminum cabinet provides corrosion and having ss condensation pan . the heat pump shoul be having scroll type copland make compressor , with high & low pressure switch protection with lakout realy & thermal motor protection againest over heating. heat pump should having factory installed inbuilt auto on/off circulation pump for condensor side. & 15 paskal static pressure centrafigul fan for Evaporator side. And having heating capacity 9.5 KW and colloing capacity around 6 KW the COP is around 3.6 the heat pumps should be suitable for 240 voltas , 50 Hz, power supplay operations. SOLAR PUMP STATIONS Pump Station with intergraded automatic LCD controller & Temperature sensors with internal temperature sensor cables with probes & suitable for single phase 230 volts, 50 Hz. -. Leading & positioning of tanks, solar panels etc. -1set Commissioning & Handing over charges for Electricl with solar system -1 set Freight -Chennai to site - 1job Freight -Chennai to site - 1job

Providing, installation, testing and commissioning of following insulated hot water recirculation pumps suitable for 415 Volts connected with T.E.F.C. induction motor, M.S. channel, base plate with nuts & bolts complete with vibration isolators, isolating valve on suction and discharge, non return valve on discharge, pressure gauges with stop cock and dial type thermometer on suction or discharge, necessary Termination with connecting cable from pump to electrical panel, lugs, earthing wire, cable tray etc. The pump shall have mechanical seal. The pump shall be SS 304 casing, impeller, shaft and CI (Epoxy coated) base (suitable for hot water temperature).(1 W + 1 S) Flow - 15 LPM Head - 30 Mtr ELECTRICAL INSTALLATION FOR SOLAR SYSTEM Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of outdoor type motor control centre shall be fabricated out of 14 gauge CRCA sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel T sections irons and/or flats wherever necessary including necessary civil foundation. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Cadmium Plated hardware shall be used in fabrication of panels. rate includes all power, control cables and cable trays with all necessary item. MCC Incoming 63 amps TPN MCCB with the following accessories: a. 0-500 volts 96 x 96 mm square digital electronic voltmeter with selector switch through 415 V/ : 3 110 V/ 3 PT primary and secondary of PTs shall be protected by 2 amps TP MCB. 1 Set b. 0-63. amps 96 x 96 mm square digital electronic ammeter with selector switch and 63 / 5 amps 10 VA CL:1 CTs. 1 Set c. Phase indicating lamps through 415/110 V PT primary & secondary of PTs shall be protected by 2 amp SP MCB 3 Sets Bus Bar 100 amps TPN (25KA) aluminium bus bar with heat shrinkable insulation sleeves. Outgoings

a. 1 Nos. 40 amps TPN MCCB with 1 Nos. 6 KW DOL starter to Heat Pump. Each compartment shall contain CT operated digital electronic ammeter of 0-40 amps range with auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor a. 2 Nos. 32 amps TPN MCCB with 2 Nos. 4 KW DOL starter to Hot water recircua;ltion pump. Each compartment shall contain CT operated digital electronic ammeter of 0-32 amps range with auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor a. 2 Nos. 16 amps TPN MPCB with 2 Nos. 1.5 KW DOL starter to solar sun pump. Each compartment shall contain CT operated digital electronic ammeter of 0-16 amps range with auto/manual selector switch and indicating lamps with MCBs and ON/OFF/TRIP status of motor b. digital temperature controller, indicatores,including necessary wiring and accessories as required. Spare: d. 1 No. 40 amps TPN MCCB d. 1 No. 16 amps TPN MPCB e. Necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also included Notes : a. All MCCB/MPCBs shall be of 25 KA breaking capacity and suitable for motor duty application. b. Provision shall be made for providing potential free contacts to all pumps starters for connection to BAS c. Provision shall be made to ensure system protection from dry running of the pump MCC - For Solar water system as described above. Total of Solar Hot Water System Works Interior Works FLOORING WORKS

Set

172

Providing and fixing of flooring with Premium quality approved make of full bodied vitrified floor tiles (seamless joint) confirming to IS 13006/EN 176 Group BIa with tech.specification as Mohs scratch hardness greater than 6,Water Absorption of 0.06%, Modulus of Rupture greater than 27 N/mm, Deep Abrasion resistant less than 204 mm cube, Surface flatness, Straightness of sides 0.25%, thickness 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.1:4 and pointing with approved make epoxy grout of to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels and as directed.Rate shall be inclusive of forming pattern as shown in dwg and wastages etc; as complete in all respects and complying with relevant standard specifications and as directed by the Engineer-incharge. Size of tiles shall be 600mmx600mmx10mm.

Sqm.

8510

173

Providing and fixing of flooring with Premium quality approved make of Matt finish, outdoor full bodied vitrified tiles (seamless joint) confirming to IS 13006/EN 176 Group BIa with tech.specification as Mohs scratch hardness greater than 6,Water Absorption of 0.06%, Modulus of Rupture greater than 27 N/mm, Deep Abrasion resistant less than 204 mm cube, Surface flatness, Straightness of sides 0.25%, thickness 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.1:4 and pointing with approved make epoxy grout of to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels and as directed.Rate shall be inclusive of forming pattern as shown in dwg and wastages etc; as complete in all respects and complying with relevant standard specifications and as directed by the Engineer-incharge. Size of tile shall be 300x300x10mm size.

Sqm.

1220

174

Providing and fixing of flooring with Premium quality approved make of full bodied vitrified floor tiles (seamless joint) confirming to IS 13006/EN 176 Group BIa with tech.specification as Mohs scratch hardness greater than 6,Water Absorption of 0.06%, Modulus of Rupture greater than 27 N/mm, Deep Abrasion resistant less than 204 mm cube, Surface flatness, Straightness of sides 0.25%, thickness 5% of size of approved colour and size & thick as specified, the tile shall be laid with 4mm thick spacer semi glossi / honed finish joints are fillied with approved make Epoxy grout (office area) and tile set in combination of Laticrete adhesive L 111 and L 73 ( cementtiious powder and latex rubberised liquid ) or Equivalent approved make to a thick not less than 6mm (for surface contact of the bottom of the virtified tile) protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels & as per approved pattern/design using irrespective of size and shape, Rate shall include for preparation of base surface & finishing as per manufacturer's Specification and as directed. (600x600x10mm) Providing flooring with best quality approved make Anti Skid Ceramic tiles ranges, sizes as listed below shall 8.0mm thick set in CM 1:4, 20mm thick and pointing the joints with Laticrete adhesive L 290 and pointing with Laticrete make Latapoxy SP 100 of approved make as per Manufacturer's Specification and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, and protecting and with Gypsum / POP layer over Plastic sheet and removing the same before handing over, work at all levels etc. as complete in all respects and complying with relevant standard specifications and as directed by the Engineers In-charge.. Size of tiles shall be 300mmx300mm. Providing flooring with best quality approved colour natural marble slab thick 20mm of size not less than 1200 x 900 mm/ 900 x 600mm, machine cut with water ( without kerosene ), set in combination of Laticrete adhesive L 111 and L 73 ( cementtiious powder and latex rubberised liquid ) or Equivalent approved make to a thick not less than 9mm (for surface contact of the bottom of the marble slab) as per approved pattern/design drawing using irrespective of size and shape, including finishing the joints with Laticrete make Unsanded Cementitious grout L 600 series or Rate shall include for preparation of base surface & finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tinoxide polish as per manufacturer's Specification and as directed.

Sqm.

3000

175

Sqm.

480

176

177

Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels and as complete in all respects and complying with relevant standard specifications and as directed by the Engineers In-charge.. The tolerance in level shall be +/-1mm. Providing and laying with best qualityof approved colur Italian marble perlato sicilio 20mm of size not less than 1200 x 900 mm/ 900 x 600mm, machine cut with water ( without kerosene ), set in combination of Laticrete adhesive L 111 and L 73 ( cementtiious powder and latex rubberised liquid ) or Equivalent approved make to a thick not less than 9mm (for surface contact of the bottom of the marble slab) as per approved pattern/design drawing using irrespective of size and shape, including finishing the joints with Laticrete make Unsanded Cementitious grout L 600 series or Rate shall include for preparation of base surface & finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tinoxide polish as per manufacturer's Specification and as directed by the Engineer-incharge.

Sqm.

1340

178

Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels and as complete in all respects and complying with relevant standard specifications and as directed by the Engineers In-charge.. The tolerance in level shall be +/-1mm. Providing flooring with best quality approved colour granite slab not less than 18 mm thick of size not less than 1200 x 900 mm/ 900 x 600 mm, machine cut with water ( without kerosene ) and factory high pre-polished, set in combination of Laticrete adhesive L 111 and L 73 ( cementtiious powder and latex rubberised liquid ) or Equivalent approved make to a thick not less than 9mm (for surface contact of the bottom of the granite slab) as per approved pattern/design drawing using irrespective of size and shape, including finishing the joints with Laticrete make Unsanded Cementitious grout L 600 series or equivalent and cutting, edge chamfering and polishing with tin-oxide / high gloss factory polish as per manufacturer's Specification and as directed. Grinding after laying for level adjusment shall not be permitted. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over,work at all levels and as directed.For steps (Raiser and Treads) instead of floor (including edge moulding with polishing and non slippery stripes etc;)

Sqm.

345

Sqm.

580

179

180

Supplying and fixing 20 mm thick granite of approved colur for counter top for wash basin laid in 20 mm thick cement mortar 1:4 over the concrete surface and edge chamfering and providing the hole in the granite for fixing the pillar cock tap etc., complete and as directed by the Engineer -incharge. Providing flooring with best quality jet Black or approved colour of leather finish granite slab not less than 18 mm thick of size not less than 1200 x 900 mm/ 900 x 600, machine cut and machine high pre-polished, set in C.M 1:4, 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern/design drawing, including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish as per manufacturer's Specification and as directed. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels and as complete in all respects and complying with relevant standard specifications and as directed by the Engineers-Incharge. The tolerance in level shall be +/1mm. Providing and fixing flooring with cement based pressed button tile of approved make, thick not not less than 22 mm thick of approved colour / pattern of specified shape & size (as per drg), over a bed of CM 1:4, 20mm thick including jointed with matching cement slurry including preparation of base surface, and finished the surface, cleaning the surface, work at all levels etc.,as complete in all respects and complying with relevant standard specifications and as directed by the Engineers-Incharge. Providing flooring with best quality approved Kotah stone slab not less than 20 mm thick and the size of slab in general not less than 1200mm long and width as per drg. machine cut and machine high pre-polished, set in C.M 1:4, 20 mm thick topped with white cement slurry (for surface contact of the bottom of the Kotah slab) as per approved pattern/design drawing by using irrespective of size and shape, including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish as per manufacturer's Specification and as complete with all respects complying with relevant standard specfication as directed by the department EngineerIncharge/Consultant. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels, as directed.

Sqm.

184

Sqm.

212

181

Sqm.

74

182

Sqm.

143

183

Providing flooring with best quality approved Kotah stone slab not less than 20 mm thick and the size of slab in general not less than 1200mm long and width as per drg. machine cut and machine high pre-polished, set in C.M 1:4, 20 mm thick topped with white cement slurry (for surface contact of the bottom of the Kotah slab) as per approved pattern/design drawing by using irrespective of size and shape, including finishing the joints with white cement slurry, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish as per manufacturer's Specification and as complete with all respects complying with relevant standard specfication as directed by the department EngineerIncharge/Consultant. Rate shall include for preparation of base surface & finished the surface, protection with gypsum/pop layer over plastic sheet and removing the same before handing over, work at all levels, as directed. For steps (Raiser and Treads) instead of floor (including edge moulding with polishing and non slippery stripes etc;)

Sqm.

1192

184

185

Providing and laying of laminated wooden flooring but in general it shall be provided with 8mm thick HDF planks of size 194mmx1286mm with factory tongue and groove joints, glue fixed and edges finished with necessary profiles of skirting / reducer as per manufactures specification. Rate shall be inclusive of providing 4mm polyethene sheets as under lay on the existing floor. The tolerance in level shall be +/-1mm. Note: Approved make shall be Tarkett Sommer or equivalent, as completed with all respect and complying with relevant standard specification as directed by the Engineer-Incharge. Supplying and fixing Imported Vinyl flooring with roll form vinyl tile of approved make & shade 2mm mm thick of standard sizes as per IS 3462 / BS 3261 of manufacturers specification over the existing floor. The rate shall include all cuttings and wastages, cutting and providing tile above electrical trunking, cost of all materials adhesives of SR-505 FEVICOL of M/s. PIDILITE Industries Ltd., make etc, including welding of joints., complete. Only laid area will be measured for payment. Rate quoted shall be for the complete finished work including all the materials and labour mentioned above. Providing, supplying & installing imported Broad loom carpet / ROLL TYPE of approved make in the specified areas as per specifications, patterns/drawing specified below. Face Construction Construction - Roll Type Yarn- recyclable Nylon

Sqm.

80

Sqm.

73

186

Gauge - 1/10 to 1/12 Pile stitches per inch : 9 to 12 Pile Height Average : 5mm Density factor Minimum 25000 to 37500 oz/cubic yard Over All Thickness : 7 to 8 mm Fiber System : Nylon Dye Method - Solution dyed yarn Soil / stain protection - suitable pretreatment required (protect) Backing System Backing System : Polypropylene Product Testing Surface Flammability Flooring radiant panel -Class1 Electrostatic property-3.0 kv or lower Colour fastness to light-great->_4 after 100 hours Adhesive system Tackifier applied to the floor meeting low VOC (Volatile Organic compound) specifications Installation Method Adhesive applied on the floor. Warranties Minimum 15 year warranty with replacement against excessive wear, edge ravel, zippering & backing reiliency loss. Warranty certificate from manufacturer to be furnished. Product Size : 3.66m width Cost Cost to include plastic covering protection after installation, shampooing before hand over, 2% attic stock, all handling, transportation, wastage, taxes and duties that are applicable etc; complete. False Flooring Providing and fixing Access floor systems of Unitile or approved equivalent make all as per following specifications confirming to PSA MOB -PF2 PS/SPU or NFPA 262 standards. System : Access floor system to be installed shall provide a maximum finished floor height of upto 600mm from the existing floor level. The system shall provide for suitable pedestal and under-structure designed to withstand various static loads and rolling loads subjected to it in an office / server / DCS / panel / rack area. The entire Access floor system shall provide for adequate fire resistance, acoustic barrier and air leakage resistance.

ii iii

iv

v vi

vii viii

Sqm.

205

187

Panels : Access Floor panel of size 600x600 mm shall be all steel welded construction, with an enclosed bottom pan of 64 hemispherical cones and top plain sheet which are fuse welded at 124 locations to form a panel of an overall depth of 37 mm. The inner empty core of the panel is injected with a light weight fire retardant, non combustible cementitious compound at high pressure to fill in all the crevices of the panel and ensures support of not less than 85% of the top surface area of the panel. The panel after cleaning, degreasing, phosphate by 7 tank process is coated with 40 micron epoxy coat and is heated to achieve maximum adhesion and surface resistance. The Panels shall be UL listed/ FM approved. The panel is then laminated with 1.5 mm thick fire retardant floor grade antistatic laminate/pvc on a semi automated lamination line to ensure maximum bonding to the steel surface. The edges of the laminated/PVC are protected with black PVC edge trim 5mm wide on all sides. This edge trim is mechanically locked and sealed in place to avoid detachment Pedestals : Pedestal installed to support the panel shall be suitable to achieve a finished floor height of 75 to 600mm. Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. Pedestal base to be permanently secured to position on the sub floor. Pedestal assembly shall provide for easy adjustment of leveling and accurately align panels to ensure lateral restrain. Pedestals shall support an axial load of 2000 Kgs, without permanent deflection and an ultimate load of 3500 Kegs. Pedestal head shall be designed to avoid any rattle or squeaks. Pedestal Assembly : Consisting of 100 x 100 x 2mm thick galvanized epoxy polyester coated MS Base plate diepressed orbitally riveted to a 21mm O.D. 2.5mm thick epoxy coated MS pipe to engage the pedestal head assembly. The pedestal head assembly consists of an embossed steel plate having 4 holes with th tapping for fastening and locating of tile ; orbitally riveted to a corresponding threaded stud 16mmdia. (O.D), length 100mm which is designed to engage the pedestal base assembly. The assembly shall provide a range of height adjustment upto 25mm, with the help of check nuts. Understructure : Understructure system consists of stringers of size 570 x 32x 20 x 1.5mm to form a grid of 600 x 600mm. These stringers are locked into the pedestal head and run both ways. The US system shall provide adequate solid, rigid and quiet support for access floor panels. The US system shall provide a minimum clear, uninterrupted height of 550 mm between the bottom of the floor and bottom of the access floor for electrical conduiting and wiring.

Stringers : Stringer system is all steel construction, rectangular channels 30 x 20 x 1.6mm thick with prepunched counter sunk holes at both ends for securing the stringers onto the pedestal head ensuring maximum lateral stability in all directions. The grid formed by the pedestal and stringer assembly shall receive the floor panel. Panel Loading: The panel dimensions and performance must confirm with PSA MOB - PF2 PS/SPU standards for a heavy duty panel and must comply with the, Concentrated Point Load : 450 kgs on a 25 x 25 mm square on the centre of the panel with a maximum permissible deflecting of not more than 2.5mm & Uniformly Distributed Load (UDL): 1200 kg/M2 with a maximum permissible deflection of not more than 2.0mm. Fire Rating : The Panels shall confirm to Class O & Class 1 Fire Ratings tested as per BS 476 Part 6 & 7 Rate shall include to produce a test certificate for the above load of approved laboratory, preparation of surface, cutting for supply/return Air Grills and for Grommet of required size, wastages, lead & lift, grouting the system with anchor fastener, removing all debris from the premises etc. complete, as directed and for providing class O Armaflex Nitrile rubber of 15mm thick as a sub floor insulation with SSR 98 adhesives to the entire area of existing (Below false flooring) as per manufacturer's specification. Rate shall inclusive of providing ramp/Steps in false flooring in the entry as shown in drawing. 188 The height of the jacks shall be 600 mm . Providing and fixing Unitile or approved equivalent makes panel lifter. The panel lifter having special two cup suction panel lifting tool, designed for heavy duty load carrying capacities with safety lever attachment which requires deliberate manual movement to unlock the panel. Supplying and fixing of barrier mat of Esplanade Plus from GRADUS MATTING. The rate inclusive of necessary edging strips/mat well frame ect, all as per manufacture slandered specification. Size as per approved drawings. Providing and fixing of SS Box section for edge guard to barrier mat as per approved drawing Size 25x25mm Sqm. Nos 375 2

189

Sqm.

190

RMT

18

191

Providing and laying 3mm thk self smoothing Epoxy floor topping over the grano flooring in recreational block areas.Grinding the surfaces, cleaning the surface thoroughly & removing laitance completely and then applying solvent free primer on the concrete surface and seeding with fine aggregates so as to get a good mechanical key and allow it dry and then applying and laying 3mm thick self-smoothing epoxy topping flowshield SL or approved equivalent make in approved colour and allow it dry. Rate shall include chipping, levelling, applying, tool & tackles,electricity, water etc.. as directed by the Engineer-Incharge. SKIRTING WORKS Providing skirting 100 mm high with full bodied vitrified floor tiles of approved equivalent make, 10 mm thick set in Laticrete adhesive L290 including pointing with Latapoxy SP 100 joint filler compound of Laticrete or approved matching shade and all as per Manufacturer's Specification. Rate shall include for chasing of wall for flushing the tile inline with wall surface, preparation of base surface and acid wash at all levels and as per drawing. Vitrified tile Matt finish. Vitrified tile Polished. Providing 100 mm high skirting with best quality approved colour marble slab of thickness not less than 18 mm, machine cut and machine high pre-polished set in Laticrete adhesive L 290 to a thick of 4mm uniformly and finishing the joints with Latapoxy SP 100 of Laticrete or equivalent make, at all levels and all as per drawing directed. Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting/ chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall Providing 100 mm high skirting with 2.0 mm thick Armstrong or approved equivalent make quartz reinforced Anti static vinyl over existing cement skirting including preparation of surface and fixing the tile using Fevicol SR998 / Vamicol FC100B adhesive and finishing the surface neat etc., complete. The rate shall inclusive preparation of base surface and protection with plastic sheet at all levels etc as complete as directed by the Engineer-incharge.

Sqm.

450

192

a b 193

RMT RMT RMT

460 11220 3820

194

RMT

200

195

Providing 100 mm high skirting with best quality approved Kotah slab of thickness not less than 20 mm, machine cut and machine high pre-polished set in Laticrete adhesive L 290 to a thick of 4mm uniformly and finishing the joints with Latapoxy SP 100 of Laticrete or equivalent make, at all levels and all as per drawing . Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting/ chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall etc as complete as directed by the Engineer-incharge. Providing 100 mm high skirting with best quality approved Jet Black granite slab of thickness not less than 18 mm, machine cut and machine high pre-polished set in Laticrete adhesive L 290 to a thick of 4mm uniformly and finishing the joints with Latapoxy SP 100 of Laticrete or equivalent make, at all levels and all as per drawing. Rate shall include for preparation of surface, with tin-oxide / high gloss factory polish. Rate also to include filleting/ chamfering of the edges along with partial recessing of the skirting into masonry / gypsum wall etc as complete as directed by the Engineer-incharge. Providing and fixing 100 mm high skirting made from 12 mm thick BWP board finished with 1.5mm laminate of approved shade & colour, bottom and top edge covered with 4mm thick polished teak wood lipping as per architectural drawing with 4 mm grooves at top enamel painted of approved colour. The ply being grouted to the GI channel etc as complete as directed by the Engineerincharge. Providing and fixing of aluminium skirting(Gradus/ALLOY or approved equivalent make) 100mm high and 1mm thick of aluminium profile of approved colour fixed at wall/partition etc as complete as directed by the Engineer-incharge. WALL DADO Providing dadoing with machine cut and machine high pre-polished best quality approved colour granite tile of thickness not less than 10mm of size 600x600mm/600x300mm, set in cement mortar 1:3, pointing the joints with approved Tile joint filler grout compound matching to the granite color and as directed. Rate shall include for preparation of base surface, such as hacking, cleaning, wastages, smooth joint, necessary corner/edge guards of matching color, cleaning and acid wash etc. etc as complete as directed by the Engineerincharge.( Lift Lobby, Corridor )

RMT

4061

196

RMT

885

197

RMT

100

198

RMT

2000

199

Sqm.

1604

200

Providing Dadoing with best quality Ceramic tile of approved make and size of 300x450mm set in cement mortar 1:3, pointing the joints with approved Tile joint filler grout compound as per Manufacturer's Specification and as directed. Rate shall include for preparation of base surface, such as hacking, cleaning and acid wash complete all as directed. Rate shall include wastages, smooth joint, necessary corner/edge guards of matching color, cleaning and acid wash etc. etc as complete as directed by the Engineer-incharge. (toilets) Providing and fixing Natural Marble Cladding slab of thickness not less than 25 mm size of approved colour & shade of size not less than 900x600 / 1200x600 mm or approved size, using dry fixing method. Each marble slab is to be individually supported using 4 Nos. of stainless steel cramps, screws & bolts are 316 'L' grade two each at top and bottom. Each SS cramp will be of size 75 x 50 x 5 mm thickness as shown in drawing and as directed. Each SS cramp will be fixed to the wall using two numbers of MS oxidized non-corrosive expansion anchor fasteners of size 10 mm head, 6 mm dia. and 100 mm length for masonry work , 10 mm head, 6 mm dia. and 50 mm length for RCC areas. Each marble slab will have two SS cramps at the bottom with the lipping of 12 mm height embedded in the groove cut in the marble, the groove depth being 20 mm and width being 6 mm etc as complete as directed by the Engineer-incharge.

Sqm.

3929

201

Each slab will also have similar 2 cramps at the top, balance gaps in the grooves will be filled with metal paste. There will be no gaps seen between the marble slabs in elevation. Any corner or junction slab which may be of smaller size should also be supported similarly. It has to be ensured that the slabs are perfectly vertical and in plumb. The gaps between the marble slabs is to be filled with water proof cement paste GRIPFIX (CICO, powder and liquid mix) as per manufacturer specifications, using matching colour pigments depending on the slabs. The gaps on the top and sides of the marble fixing will have to be closed using coping slabs to prevent water from coming in. Rate shall include for fabrication and fixing of SS cramps, anchor fasteners, supplying and fixing Mseal, water proofing compound, groove cutting in granite and double scaffolding to the required heights, wastages etc as complete as directed by the Engineer-incharge. for lift lobby.

Sqm.

420

202

Providing and fixing in wall dado with best quality approved make Screen printed ceramic tiles ranges, sizes as listed below shall 6.0mm thick with matching borders and set in CM 1:4, 15 mm thick and pointing the joints with Laticrete adhesive L 290 and pointing with Laticrete make Latapoxy SP 100 of approved make as per Manufacturer's Specification and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, and work at all levels etc. as complete in all respects and complying with relevant standard specifications. Rate shall include wastages, smooth joint, necessary corner/edge guards of matching color, cleaning and acid washetc as complete as directed by the Engineer-incharge. Size of tiles shall be 300mmx300mm (Kitchen, utility etc..) Total of Flooring Works Sqm. 340

203

204

PAINTING WORKS Providing Acrylic emulsion paint - Painting with acrylic emulsion paint of Low VOC paint ( complying with all green rating systems) and of approved make and colour or equivalent make two or more coats as per manufacturers specifications and as directed. The rate shall be inclusive of necessary scaffolding or staging etc.as complete with all respects complying with relevant standard specification, as directed by the EngineerIncharge. Providing and applying of "Royal Play" paint from Asian or approved equivalent make. to walls of approved colour over a coat of primer as per manufacture specification. The rate shall be including preparation of surface by thorough cleaning and as per manufacturers specification fully to give an even shade s directed by the Engineer-Incharge. Providing & applying POP punning plaster 6-10 mm thick over exposed wall surface including scaffolding etc. complete. Rate to include for making the wall with plumb line and get smooth surface to receive the paint.( all plaster surface) and also include cost of material, labour, unloading and shifting of material,water etc..as complete and as directed by Engineer-Incharge. Providing two coats of synthetic ready mixed Enamel paint to wooden / steel work of approved colour over a coat of respective primer including preparation of surface by through cleaning as per manufacture's specification fully to give an even shade etc..as complete and as directed by Engineerin-charge. Total of Painting Works FALSE CEILING WORKS

Sqm.

75746

Sqm.

50

205

Sqm.

75746

206

Sqm.

1855

207

Providing & Fixing of Eco Perforated metal Lay in ceilings System (Fameline/Armstrong or approved equivalent make) consisting of 600x600mm Lay in tiles made of Aluminium Alloy 1100 with powder coated(polyester base) to 60 microns in 0.7 mm thickness in approved colour with standard perforation of 2.6mm dia & open area of 17% and Freudenberg Soundtex acoustical fleece glued to the back of the tile to be laid on grid systems with 15mm wide T - section flanges colour white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test. The tiles should have Humidity Resistance (RH) of 100%, NRC of 0.70, Fire Performance A2-s1.d0 in module size of 600 X 600 mm, suitable for Green Building application, with Recycled content of 50%. The Tile & Grid system used together should carry a 15 year warrantee. INSTALLATION: To comprise main runner spaced at 1200mm centers securely fixed to the structural suffix at 1200mm maximum centre & not more than 150mm from spliced joints. The First/Last suspension system at the end of each main runner should not be greater than 600mm from the adjacent wall. 1800mm long cross tees to be interlocked between main runners at 300mm centre to form 1800 x 300 mm module. Cut cross tees longer than 600mm require independent support. Perimeter trim to be wall angles, secured to walls at 450 mm maximum centers. The rate shall be inclusive of making openings for light fittings, grills, diffusers, cutouts, wastage and

necessary hardware etc. as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.(hall ) a b For the above specification for Grid system For the above specification for board (measurement only laid area) Sqm. Sqm. 2434 2434

208

Providing and fixing in true horizontal level false ceiling of 15mm T-section grid system Manufactured by M/s. Saint Gobain/Armstrong/USG/Daiken or approved equivalent make using hot dipped galvanized steel section, exposed surface chemically cleaned capping prefinished in baked polyester paint, wall angle of size 3000 x 19 x 19mm used in the periphery of the ceiling fixed to the wall partition / R.C. Column / band walls with the help of screws at 600 mm C/C. Main runner spaced at a 1200mm C/C suspended by using 2mm dia G.I. wire hanger securely fixed to the structural soffit of RC slab by using 6mm anchor fastener at every 1200mm (max) and 1200mm long cross tee to be interlocked between in Main runner at 600mm C/C (max) to form a grid of 1200 x 600mm. 600mm long cross tee fixed in between 1200mm long cross tee for forming a grid of 600 x 600mm.

Laying of FINE FISSURED (MICRO LOOK) tiles should have Humidity Resistance (RH) of 99%, NRC 0.55, Light Reflectance >85%, Thermal Conductivity k = 0.052- 0.057 w/m K, Colour White, Fire Performance Class 0/ Class 1 (BS476 Part 6&7) in module size of 600 X 600 X 16 mm with Bio Block coating on the face of the tile, suitable for Green Building application, with Recycled content of 63%. as complete in all respects complying with relevant standard specifications and as directed by the Engineer-incharge. a b 209 For the above specification for Grid system For the above specification for Fine fissured board (measurement only laid area) Providing and fixing mositure resistant seamless gypsum ceiling with Gyproc MR or approved equivalent make of 12.5 mm thick, fixed to the underside of the suspended grid formed of GI perimeter channel of size 20 x 28 x 30 mm fixed along the wall by using wood screws and metal expansion rawl plugs. The GI intermediate channel of size 15 x 45 x 15 x 0.90 mm shall be fixed to the suspended strap hanger / GI ceiling angle at intervals not more than 1220 mm. The suspended GI ceiling angle /. Strap hanger is to be connected with GI soffit cleat of size 37 x 27 x 25 x 1.6 mm and it should be fixed on the roof slab / beam, by using metal expansion fasteners (wt. Type) of 12.5 mm dia. to a length of 35 mm with 6 mm dia. bolt / screw at top ends. Sqm. Sqm. 1665 1665

The GI ceiling section of size 80 x 26 x 0.5 mm (MF 5) is to be provided across the intermediate channel at intervals not more than 457 mm centres at bottom and the same shall be fixed by GI connection clips 2.64 mm dia. at the intersection points. The ends of ceiling section channel by adopting an overlap length of minimum 150 mm, connected with intermediate channel shall be fixed to perimeter channel in insertion. The gypboard shall be fixed to the under side of the suspended grid by using 25 mm long dry wall screws. The joints shall be finished with joint paper tape by using jointing compound of Saint Gobain Gyproc or approved equivalent make and applying over it 3 layers of the filler compound to provide a smooth surface. The ceiling surface shall be painted with three coats of approved first quality acrylic emulsion over a coat of primer etc. complete. The rate shall include making cutouts for tube lights, spot lights, duct doors, for specified size, grills etc. for which no extra will be paid separately. Rate shall include providing additional trimming around cutouts for light fittings etc. and grills also for providing additional supports from ceiling where main / cross members are cut for light fittings etc. Rate shall include vertical as well as horizontal surfaces as per detailed drawing. Actual seen surface of horizontal and vertical will be measured and paid for, as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge. Total of False Ceiling Works 210 PARTITIONS Providing and fixing of Partition total four layers of GYPROC FIBRE CEMENT BOARD or approved equivalent, each layer 12mm thick (in staggered pattern) is screw fixed with drywall screws(zinc chromium plated, self drilling ) of 25mm/35mm at 300mm centres two layers on each side of 70mm Rondo/Gypsteel ultra GI C-stud {0.5mm thick having one flange of 34mm and another flange of 36mm) placed at 610mm centre to centre in 72mm Rondo/Gypsteel ultra GI floor Channel (0.55 mm thick have equal flanges of 32mm) which is anchored to the floor & true ceiling using anchor fasteners. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape. Sqm. 1917

The additional supports shall be provided to the vertical stud and RCC slab above the false ceiling at top with 'Y' type supports. Air gap between the plasterboards is lined with 50mm rock wool of density 48 Kg/m3 of approved make shall be placed in the cavity rock wool rapped with 40GSM fiber glass tissue. The contractor must ensure that the wool is wire-braced to prevent it from lumping down over a period of time. Fixing of channels shall also to provide suitable for attachment of fixtures to the partitions and the perimeter opening should be trimmed with studs packed with best quality treated timber frame to a required size and shape with 2 coats of fire proof paint over a coat of anti-termite treatment / anti-corrosive primer to receive screws / anchor fasteners to fix Joinery frame in position etc. as per drawing as complete in all respects complying with relevant standard

specifications and as directed by the Engineer-in-charge. a rate shall be inclusive of 12mm thick BWR ply boxing for fixing Switches, sockets, Backup box etc on the partition to a required size and shape.(all lab partition) Specification same as above but providing two layers of board at one side of the stud for wall paneling/column paneling Extra rate for over the above, for providing Resin bonded rock wool 50mm to (acoustic insulation material) density of 48kg/cum in solid partition to make it as acoustic proof. Providing and fixing of 1.0mm thick laminate of approved color and shade with grooves and lines and in patterns drawing on specified area as instructed by Engineer-Incharge. The cost of necessary hardware's, adhesives, wastages etc; as required for complete the works. Actual visible surfaces only will be measured and paid. Providing and fixing of 3.5mm thick veneer of approved color and shade with grooves and lines and in patterns drawing on specified area as instructed by EngineerIncharge, exposed surfaces of veneer shall be finished with melamine polish of required level. The cost of necessary hardware's, adhesives, wastages etc; as required for complete the works. Actual visible surfaces only will be measured and paid. Finishes shall made at Factory only installation at site(portal and DH cabin) Sqm. 2710

Sqm.

375

211

Sqm.

2160

212

Sqm.

950

213

Sqm.

810

214

Providing and Fixing of 12.5mm Gypboard and the joints between the gyp-boards are finished flush and even with jointing compound and paper tape and the surface shall be painted with 3 coats of acrylic emulsion paint of approved make and shade over a coat of primer suitable for gyp-board after E-Mix / Pop / Gypsum putty and all as per manufacturers specification etc complete and all as directed. Rate shall include for providing all hardware's, etc.complete as per drawing as directed.. Providing and fixing toughened glass panel to the specified thickness as given in below in the solid partition (laminated/Veneer/ calcium silicate/Gypsum board). The frame work in the the glass panel circumference shall be fixed with 75mmx19mm size first class teak wood frame and fixing the toughened glass at the centre of teak wood frame using first class teak wood beadings to shape and size as per drawing. The exposed teak wood surfaces shall be finished with melamine polish. The rate to be include the cost of necessary hardware's, adhesives, wastage etc; as required for complete the works. Actual seen glass surface area will be measured and paid.

Sqm.

215

a b 216

217

Single layer 8mm thick toughened clear glass 6mm thick lacquered glass of approved colour and Saint Gobain or equivalent make Providing and fixing of 6mm thick lacquered glass of approved colour and Saint Gobain or equivalent make over the existing partition, paneling or wall surfaces as per drawing as directed. The rate shall be inclusive of necessary SS Stud/Double side 3M sticker, hardware and wastage etc; complete. Providing and fixing Partition above the false ceiling level using total two layers of GYPROC FIBRE CEMENT BOARD or approved equivalent, each layer 12mm thick (in staggered pattern) is screw fixed with drywall screws of 25mm / 35mm at 300mm centres one layers on each side of 70mm Rondo/Gypsteel ultra GI C-stud {0.5mm thick having one flange of 34mm and another flange of 36mm) placed at 610mm centre to centre in 72 mm Rondo/Gypsteel Ultra GI floor Channel (0.55 mm thick have equal flanges of 32mm) which is anchored to the partition bottom & true ceiling using an anchor fasteners. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape as per manufacturers specification, as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.

Sqm. Sqm. Sqm.

5 5 15

Sqm.

630

218

219

Providing and fixing of single layer 9mm thick calcium silicate board in the existing aluminium/GI partitions except the cost of aluminium/GI frame work. The joints are to be finished with jointing compound as per manufacturers specification. The boards shall be fixed with counter sunk stainless steel / fully threaded self tapping screws of suitable dia and length at every 300 mm c/c. The rate shall be inclusive of necessary scaffolding, hardware etc.complete. (above false ceiling solid partition) Straight Glazed Partition-(Type "A" partition) Slim line partition of JEB/Alloy Make or equivalent approved make: Supply and installation of full height straight glass partition 12mm thick toughened glass and proprietary anodized aluminium sections of the SLIM LINE series of 40x18mm size as per drawing as directed. The sections shall be matt natural anodized and Alloy sections combination of 40.02 , 40.03, 40.05 & 40.06 and 40.07 would be used on all four sides as per specifications and shall be inclusive of all accessories. for FFL to the bottom of false ceiling height. Wide line Section at around Door as per drawing, JEB/ALLOY Make or equivalent approved make at three sides of door opening : Supply and installation of wide line door frames using Alloy sections combination 100.02 , 100.03, 100.05 & 100.06 and 100.07 would be used at sides and top etc. as per specifications and shall be inclusive of all accessories.. The section shall be matt natural anodized as per manufacturer's specification. The rate shall be inclusive of necessary additional plate provision for fixing of card reader and access control switch etc.

Sqm.

950

Sqm.

1200

220

RMT

10

221

Supplying and fixing Fully openable Patch Fitting partition and door of ' DORMA' "PT" range Fittings to get a clear height with top & Side Fixed panels as per drawing as directed. In general, the openable door cum Fixed panel consists of sliding channel with all fitting and Corner Fittings PT90/91, Standard Spindle US10, corner lock at bottom and US20 with GK50, Euro profile cylinder with 4keys, lock keeper plate, Pull handle(TGDI35025) SS Satin Finish and 12mm thick clear toughened glass as per design and all confirming to manufacturers specification. SS fixtures shall conform Grade SS 304 to BS 7352. Rate shall include for providing Glass Fin to support the Patch Fitting Door, transport charges, handling, loading and unloading, Installation, protecting the module and glass till handing over, testing, commissioning all necessary hardware's, Structural supports if any, etc. complete and all as per manufacturers specifications as directed. Rate for partition only Rate for single/double leaf doors only.

a b

Sqm. Sqm.

5 10

222

223

Glass Etching: Fixing to glass panels using 3M film stickers as per required pattern drawing and shape and as directed by the Engineer-Incharge. Providing and fixing of 2hr fire rated partition total four layers of GYPROC FIRELINE BOARD or approved equivalent, each layer 15mm thick (in staggered pattern) is screw fixed with drywall screws of 25mm/35mm at 300mm centres two layers on each side of 70mm Gypsteel Ultra / Rondo GI C-stud {0.50mm thick having one flange of 33.5mm and another flange of 35mm) placed at 610mm centre to centre in 72mm Gypsteel Ultra / Rondo GI floor Channel (0.55 mm thick have equal flanges of 32mm) which is anchored to the floor & true ceiling using M6 x 40 anchor fasteners. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape. The additional supports shall be provided to the vertical stud and RCC slab above the false ceiling at top with 'Y' type supports. Air gap between the plasterboards is lined with 50mm rock wool of density 64 Kg/m3 of approved make shall be placed in the cavity rock wool rapped with 40GSM fiber glass tissue. The contractor must ensure that the wool is wire-braced to prevent it from lumping down over a period of time. Fixing of channels shall also to provide suitable for attachment of fixtures to the partitions and the perimeter opening should be trimmed with studs packed with best quality treated timber frame to a required size and shape with 2 coats of fire proof paint over a coat of anti-termite treatment / anti-corrosive primer to receive screws / anchor fasteners to fix Joinery frame in position etc. complete as per drawing as complete in all respects complying with relevant standard specifications and as directed by the Engineer-in-charge.

Sqm.

403

Rate shall be inclusive of 12mm thick BWR ply boxing for fixing Switches, sockets, Backup box etc on the partition to a required size and shape.(all lab partition)

Sqm.

1450

224

Providing and fixing of fully glazed steel fire rated partition and door with 120 minutes of integrity (E=120) fabricated with 1.6 mm thick galvanized steel sheet. The door frames are manufactured from 1.6 mm galvanized steel sheet pressed to form a profile of 35 mm x 60 mm onthe vertical sides and 50 x 60 mm on the horizontal side. The door shutter would have a top rail and side rail 60 mm x 60 mm and a bottomrail of 110 mm x 60 mm. The overall door opening is 1800 mm x 2100+fixed 1800x1700mm. The test is conducted in CBRI, Roorkee as per BS 476 Part 22. The glass should be SGGCFDL 11mm clear 120 min rated ( E120) Non Wired Toughened glass with a light transmission of 89% and a sound reduction of 32 db. The glass should be class 1C1 category of Impact Resistance as per EN 12600. The glass should be held in its place with the help of 2 mm GI beading and a special ceramic tape with cross section of 5 x 20 mm..

The shutters should be fixed to the frame using 4nos of Dorma SS Ball Bearing Hinges of size 100 mm x 75 mm and 3 mm thickness. Beading should be attached using 4 mm x 35 mm SS screws at a distance of 75 mm from the edges and 150 mm c/c henceforth. The door should be fitted with Dorma Mortise Sash lock 952F and door closer TS 68 of Dorma make or equivalent. The inactive leaf should be fixed to the frame using 1200mm long Dorma tower bolt no 9114306 or equivalent. (SAINT GOBAIN 11mm CONTRA FLAME or approved equivalent make) a b 225 For partition only(UPS and server) For single/double leaf doors only(lobby) GUIDE SPECIFICATIONS FOR OPTRA ACOUSTICAL WALL PANELLING:Providing and supplying Armstrong Optra Acoustical Wall Panelling or approved equivalent make with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire-resistant fabric with an option of colours as per the choice of the EngineerIncharge/Consultant of size 2100x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers supplied by M/s Armstrong Industries India Pvt. Ltd and construction adhesives as per the instructions laid down by the manufacturer. Sqm. Sqm. 40 19

INSTALLATION: Armstrong or approved equivalent wall panel impalers of adequate quantity as specified by the manufacturer shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive shall be dabbed on to the projecting elements (spikes) of the impalers. Armstrong Optra wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained. The rate shall be inclusive of wastage, hardware and necessary backings etc. 226 GUIDE SPECIFICATIONS FOR ARMSTRONG OR APPROVED EQUIVALENT MAKE CHANNELED WOODWORKS WALL PANELLING OF SIZE: 128X2440X16MM Providing and Fixing Armstrong Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm or as required by the Engineer-Incharge/Consultant, made of a high density particle board substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (Helmholtz fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be tongueand-grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips provided by Armstrong or approved equivalent make and approved by the Engineer-in-Charge

Sqm.

214

INSTALLATION:Install wooden battens (provided by others) of section 50mmx50mm or as approved by the Engineer-Incharge/Consultant on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks (GTPT001) over the lowest and second wooden batten at an on-center distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks (GTPT002) and insert the groove of the panel into the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodworks (GTPT003) into the next keel till the actual height is achieved. Use clips for border channelled woodworks (GTPT002) to finish off the installation. Finish off the edges using wooden moulding of matching colour. The rate shall be inclusive of wastage, hardware and necessary backing etc.

Sqm.

232

Total of Partition Works 227 72 Joinery Providing and fixing of well seasoned teak wood door frame approved size and as per drawing detail. All exposed wooden surfaces are duly polished with melamine polish of required level. The rate shall be inclusive of making necessary design as per drawing, in the frame and necessary hold fastener and hardware ect,. The rate shall be inclusive of supply and fixing of 6 nos MS flat iron holdfast for each door of size 40mmx3mm and 40CM long fixing with CC 1:2:4 and 75mm long 10mm dia anchor fastener to RCC location where ever required. Finishes shall made at Factory only installation at site Scantling shall be up to 2000mm length Scantling shall be above 2000mm and below 3000mm Providing and fixing of 35mm thk.Teak wood panelled shutter with door frame of approved size and all as per drawing. All the wooden surfaces are duly polished with mellamine. The rate shall be inclusive of necessary anchor fastener and excluding hardwares, as directed by Engineer-Incharge/Consultant. Providing and fixing of factory finished solid wood mahogani door jamb of size as mentioned below (full wall thick) with necessary door stoper(40x22mm), architrave(40x15mm) or approved size and all as per drawing detail. All the wooden surfaces are duly polished with PU finish of required level. The rate shall be inclusive of making necessary design as per drawing, in the frame and necessary hilti fastener and hardware etc,. Finishes shall made at Factory only installation at site. CUM CUM Sqm. 2 7 139

a b 228

74

229

74

i ii iii iv 230 74

size of the door frame 230x37mm with two side architrave size of the door frame 230x37mm with one side architrave size of the door frame 115x37mm with two side architrave size of the door frame 115x37mm with one side architrave Providing and fixing 35mm thick flush door shutters of solid core block board type bonded with phenol formaldehyde synthetic resin thermo pressed with 8mm thick teak wood external edge lipping finished with melamine polish of approved make, colour & pattern as per drawing. The construction procedure of the shutter should be as per IS:2202.The size of block, shall perfectly correspond to the maximum size of lock, covered in IS:2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc. The rate shall exclusive of hinges and other hardwares; complete as directed. specification same as above but the finishing of door shutters on both sides with 1.0mm thick laminate of approved color pattern. specification same as above but the finishing of door shutters on both sides with 3.5mm thick veneer of approved color and finishing with melamine polish.etc. complete, directed by the Engineer -incharge The basic cost of veneer. The rate should be quoted for single side area of the door shutter. Providing and fixing in position first quality teak wood beading / architrave of finished size as given below, made to shape and pattern approved with necessary pins, nails, screws, bolts using teakwood conforming to specification. Rate shall include two coats of Duco Paint over a coat of wood primer etc. as directed. Size : 25 x 12 mm 2hr. Fire rated hollow metal doors - Painted Providing and fixing of Hollow metal fire rated doors at all levels from ISO 9001-2000 certified Manufacturer. Fire door should be as per IS 3614 part-1 & part-2 and BS 476 part 2 or EN 1634. Recommended fire door shall be tested and certified by a third party evaluation program from approved international agency like CERTIFIER and labeled. Where third party evaluation is not required fire doors should be tested at CBRI or ARAI for maximum rating of 2hrs both with vision panel and without vision panel. Pressed Galvanized steel Single /Double leaf door of approved make shakti met-dor or approved equivalent which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277.

RMT RMT RMT RMT

647 380 3075 35

Sqm.

259

Sqm.

1059

231

RMT

3970

232

Door frame shall be double rebate profile of size 143 x 57 mm made out of 1.60mm (16gauge) thick galvanized steel sheet. Frames shall be Mitered and field assembled with self tabs. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers should be provided on the striking jamb. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be of size 200x300mm provided as per manufacturers recommendation with a beading and screws from inside. The glass should be 6mm clear borosilicate fire rated glass of relevant rating of the door. All doors and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved RAL colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate should include supply and installation of door and hardware size as mentioned below 2Hrs Fire Rated Door Single leaf of size : 600x1500mm without vision panel (shaft door) 2Hrs Fire Rated Door Single leaf of size : 900x2100mm with vision panel with Self adhesive sponge seal for frames 188S 2Hrs Fire Rated Door Single leaf of size : 1000x2100mm with vision panel with Self adhesive sponge seal for frames 188S, 2Hrs Fire Rated Door Single leaf of size : 1200x2100mm with vision panel with Self adhesive sponge seal for frames 188S, 2Hrs Fire Rated Door Double leaf of size : 1500x2100mm with vision panel with Self adhesive sponge seal for frames 188S. Providing and fixing of hardware set of DORMA or approved equivalent make for the below said item as listed below.

a b

Sqm. Sqm.

255 27

Sqm.

206

Sqm.

30

Sqm.

28

233

a b c d e f g

k l m n o p q r

Dorma BB 4330- 2 Ball bearing butt hinges size 4" x 3" x 3mm in SS 304 for Flush Doors Dorma BB 4330- 2 Ball bearing butt hinges size 4" x 3" x 3mm in SS 304 for Fire Doors Push Plate Dorma 9160010 of size 350 X 100 mm x 1.2mm in SS 316 grade Dorma H type TGDI 350 x 25 in SS 304 Dorma D type Handle 150 x 19mm in SS 304 for shaft doors Dorma Flush Pull Sliding door rectangular Dorma Mortise dead lock 278 with Europrofile Cylinder 60mm Length Type 2 (one side key other side thumb turn) with 4 level Master Key Dorma Mortise dead lock 278 with Europrofile Cylinder 60mm Length Type 1 (both side key) with 4 level Master Key Dorma TH 123 Type 2 Lever Handle with Mortise sash lock as per DIN 18251-1, class 3 & Europrofile Cylinder 60mm Length one side key other side thumb turn with 4 level Master Key One point panic device PHA 2001 - PHA 2102 PHA 2105 L = 1300mm, External Trim PHT 3905 preferred for Euro Profile Cylinder, EP Half Cyl 3010, 5 Pin one side key with 4 level Master Key SL - 400- Sliding Door Lock Dorma Mortice shaft dead bolt 57 mm backset as per DIN 18251-1 Class 3 with Alan Key Dorma TS 92 cam action door closer Concealed flush bolt Dorma 3100 Dorma Flush Bolt Door stopper Dorma-3108 Dorma Door Stopper for Residence Patch Fittings from Dorma Bottom Patch - PT 10, Floor Spring - BTS 75 V, Top Patch - PT 20, Top Pivot - PT 24 Patch Fittings from Dorma Bottom Patch - PT 10, Floor Spring - BTS 80 V, Top Patch - PT 20, Top Pivot - PT 24 Dorma SLM 120 Sliding door system for Flush door, 2 Mts Length, SLM 120 Accessories- 01 set , SLM Track - 2 Mts 01 set Providing hardware set of YALE / LOCKWOOD or approved equivalent make for the below said item as listed below. YALE - M8773 D3 - ENTRANCE HANDLE SET Elegance Series D Handleset Design with 2 keys and 3 level Master Key YALE - 6688 SC - ENTRANCE HANDLE SET BALI SERIES with 2 keys and 3 level Master Key YALE - CA5137 ENTRANCE KNOB LOCK with 2 keys and 3 level Master Key YALE - CA5132 PRIVACY LATCH with 2 keys and 3 level Master Key LOCKWOOD - DSS 03- 180 Degree Door Viewer

Nos Nos Nos Nos Nos Nos Nos

2403 1202 10 255 271 4 211

Nos

12

Nos

48

Nos

96

Nos Nos Nos Nos Nos Nos Nos Nos

4 263 190 1 743 46 597 158

Nos

37

Nos

234

Nos

b c d e

Nos Nos Nos Nos

97 533 146 102

LOCKWOOD - DSS 02- Security Door Guard Total of Joinery Works MISCELLANEOUS Providing and fixing Reception table made to shape and pattern identical as per Drawing. and to a height of two levels 1050 mm/ 750 mm , but in general it shall be made of 18mm thick BWR plywood as table top, sides, front and rear side with adequate supports as directed in both horizontal and vertical directions. Providing drawers unit with three drawer as per drawing, and side storage with openable postformed edge shutters and one intermediate shelf at one sides of the table. All the front, sides surfaces finished with combination of corian material of approved color and 6mm thick milky white glass with inside light provision as per drawing detail, Table top at 750mm with 25mm thick exterior grade particle board with postformed laminate (campagne shade from Merino) and at 1050mm ht top shall be finished with corian material of approved color. Rate shall be inclusive of providing edge molding of approved shape, making cut open in the table as per drawing detail, storage shutter and drawer are made with 18mm thick BWR ply finished with 1.5mm thick laminate of approved colour and other recessed surfaces are finished with 1mm thick laminate. Rate shall include for necessary wastages, hardware's(Hettich) like sliding runners, auto closing hinges, locking facility with one master key for Two drawers and storage, araldite adhesive for fixing corian etc. Rate to include for providing teakwood lipping, teak wood foot rest duly finished with melamine polish etc. All factory finished as per drawing.

Nos

102

235

RMT

12

236

Providing and fixing soft board panel of specified sizes having 12 mm thick soft board covered with felt fabric of approved make and shade of premium quality The board shall have beech wood beading, lipping all-round. The board shall be fixed on prepared surface with necessary hardware fittings etc. complete. All concealed wood works shall have sealer polish as directed. Rate quoted shall be for the complete finished work including all the materials and labour mentioned above. Providing and fixing Pelmet made to shape and sizes as given in below, but in general it shall be made out of 18mm thick BWR plywood and lined with 1.5mm thick lamination of approved colour as directed. The rate shall be inclusive of necessary accessories like hangers rods/ Hilti anchor fasteners, sunken screws etc; complete. All factory finished Same as above specification but the size of the pelmet shall be 150x150mm Same as above specification but the size of the pelmet shall be 300x150mm

Sqm.

165

237

a b

RMT RMT

15 465

238

239

Providing and fixing Drapery rod, using decorative aluminium tubular pipe with approved color powder coating of required length. Rate to include side covering heads, required number of holding bracket and necessary hardwares etc. Providing sill level covering 150mm to 300mm wide with 18mm thick 1st quality jet black granite of approved shade set in Laticrete adhesive L290 including pointing with Latapoxy SP 100 joint filler compound of Laticrete or approved matching shade and all as per Manufacturer's Specification. Rate shall include for making edge bull noising with good polishing, preparation of base surface and acid wash at all levels and as directed. Providing and fixing of Digitally reproduced Scotch print decorative 3M graphics (with controltac & comply feature for direct, bubble-free application on walls) as per the theme selected by clients with UV protective matte over laminate. Customized imagery. The rate shall be inclusive of material, Hardware for fixing the graphics and fixing charges etc. Providing and fixing of imported wall paper of approved design, fixing details as per manufacturer standard etc all complete as directed by the Engineer-Incharge. Providing and fixing matt finish white mark writing board of enamelled sheet steel front, GI back over approved inner core, of specified size black or chocolate colour anodised aluminium beading to form the screen including the necessary accessories such as magnetic symbols, magnetic letters, magnetic strips, magnetic eraser, magnetic dry marker 4 Nos., spare felt for eraser, board fixing clips etc. and the board shall be made out of enamelled sheet with backing of AC sheet to suitable thickness etc. complete and all as per manufacturer's specification and as directed by the Engineer-Incharge. The rate include excise duty, sales tax and surcharge, central excise duty, delivery charges and fixing charges, if any etc. complete and all as directed by the EngineerIncharge/Consultant. Rate shall inclusive of making and fixing wooden ledge for full length of the board for keeping marker pen, eraser etc. Rate quoted shall be for the complete finished work including ledgeboard to keep accesories , and all materials and labour mentioned above.

RMT

1126

RMT

465

240

Sqm.

10

241

Sqm.

20

242

a b c d

Size of 2400 x 1200mm(meeting room) Size of 1800 x 1200mm Size of 1500 x 1200mm (Head room) Size of 450x600mm(cabins)

Nos Nos Nos Nos

3 1 3 94

243

Providing and fixing vertical blinds with 89/75 mm wide imported superior polyster base fabric vanes with Scotchguard application as per approved sample, make of Vista Levellor or approvred equivalent make and the ranges of louver shall be in ' Select and Classsic'. The vertical blinds shall have a head rail of extruded anodised high strength aluminium alloy, shall be 25 mm x 50 mm high or equivalent with wall thickness of 1.2 mm or equivalent. End control units consists of reduction gearbox having the reduction ratio of 3.:5:1 for a very smooth operation of the blind.This unit consists of planetry gear in the outer housing,four small tranmission gears fitted in the middle assembly and a end receiving gear attached to central sprocket unit. Tilter chain is made of 4.5mm plastic beads moulded on 2.2mm thick polyster card.The pitch of the beads is 6mm.The end control unit have the facility to rotate the louver by 180 degrees.Tilt rod is made of extruded aluminium having 3 keyways and the average dia shasll be 5.8 mm .Carrier ( Runner ) is made of moulded plastic having anti friction additive.It consists of polymer housing with wheels mounted on sides & has a gear and worm mechanism with vertical worm fixed with a tongued poly-carbonate stem to hold the louvers. Spacer is made of Moulded Derlin having friction additive. The vanes shall be capable of 180 deg. rotation in position and shall be of polyester / viscose yarn dyed in fast colors a strain resistant chemicals treatment or equivalent protective coating shall be applied on vanes. The installation shall be complete in all respects.(N&S) Sqm. 841

244

245

Specification same as above but the fabric shall be made of specially coated non-curl Blackout fabric to repel oil / water / stains, with complete fittings and front valance as per approved sample and make including reduction gear tilter louver (E) Providing & fixing Motorized Black out Roller blinds conforming to specifications The Drive units -Shall be of Moulded plastic with rectangular support pin and inserted into the tube end .It shall be driven by a ball chain pulley with ball chain and can be positioned at right hand or left hand side of the shade. The shade when lowering or raising ,shall be automatically locked in position upon release of the ball chain by means of built in friction lock End Plug-Shall be Moulded of plastic with allocation pin .The plug shall be inserted into tube end.(Opposite to drive unit)

Sqm.

Support Brackets-Shall be of zinc plated steel & provided with moulded plastic covers and used in right hand or left hand positions differentiated by the acceptance of the rectangular drive unit support or the round idler plug pin Bottom Rails-Shall be stiffening element inserted into a bottom rod pocket. The material may be timber ,PVC covered steel tube or VB bottom rail. Ball Chain -Shall be 2mm diameter cord with 4.5mm diameter acetal balls moulded co-axially to it on 6mm pitch to form a endless ball chain .It is used for raising or lowering action of the shades. Fabric-1)Basic material -100% polyster2)fabric weight 170g/sqm3)Thickness -4mm 5)Finishing -Blackout fabric ,reverse & front side pigment color coated Light Fitness -Confirming to DIN54004/DIN EN ISO 105B02>/5-6 Shrinkage % ge-Confirming DIN 53892 B2 <0.5% Light reflection -82% Light transmission -0% Light absorption -18% Providing and fixing of window curtain with necessary fleecy and folds of approved make, color and pattern etc.. all complete as directed by the Engineer-Incharge. Providing and fixing plywood 8mm BWR ply, rate shall be inclusive of necessary hardware, adhesives wastage and necessary edge beading etc. at level. Preparing the surface, making and fixing of POP cornice at the junction of wall and ceiling. The rate shall be inclusive wastage, mould, scaffolding, cleaning the surface etc. size as mentioned below size diagonally 150mm size diagonally 200mm Providing and fixing of key cupboard all as per drawing detail, using 18mm thick BWR ply for all vertical and horizondal, providing glass shutter with necessary frames and all the surfaces of ply shall be finished with 1mm thick laminate of approved shade. The rate shall be inclusive of wastage, necessary hardware hinges, handle, Key hooks, lock and tower bolt etc. all the wooden surfaces shall be finished with sealer polish. size 600x900x300mm Supplying and fixing of MS powder coated Letter Box of approved size and shape as per drawing as directed 1150 ht x 900 w x 100D. Cluster of 21 Boxes Providing and fixing of mirror But in general 6mm thick mirror with aluminium frame for backing frame fixing with 12MM thick BWR ply fixing with stainless steel studs.

Sqm.

60

246

Sqm.

170

247

Sqm.

248

a b 249

RMT RMT Nos

1350 6500 4

250

Nos

251

Sqm.

35

252

Providing and fixing of 50mmx50mm size Column Corner Guard (DURAL or equivalent make), for vertical corner's of RCC columns, Brick pillars, Brick walls, Partitions, using sub frame of 1.5mm thick aluminium profile fixed in to the above corner surfaces by using anchor fasteners. Then the top covering with Rigid PVC panel profile is to be fixed on the sub frame by interlocking. The rate shall be inclusive of necessary hardwares etc; complete as per drawing as directed. Providing and fixing of netlon, using necessary all round Velcro on the window frame and netlon. The rate shall be inclusive of necessary hardware, stapler etc. Pigeon hole Rack: Providing and installing pigeon hole rack size as shown in Dwg.but in general it shall be made of 18mm BWR ply all exposed surfaces are finished with 1.5mm tk. Laminate of approved colour shade. Rate shall be inclusive of providing teakwood lipping of specified sizes, necessary hardware's etc;complete.(Size shall be 450mm deep and 2100mm ht. and pigeon hole size 375mmx375mm). Providing and fixing storage unit to a width of 600mm and 2100mm height as per drawing but in general, it shall be made out of 19 mm thick BWR plywood on all sides and intermediate shelves with necessary and the openable shutter shall be made out of 19mm thick BWR plywood with necessary teakwood supports etc complete. All exposed surfaces shall be finished with 1.5 mm thick Laminate of approved shade and all inner / recessed surfaces shall have 1mm thick laminate finish of approved shade. Rate to include all hardware's, auto closing cabinet heavy duty hinges, handles - of approved make, including locking arrangements with master key of approved make etc. complete.(lab sample record)

RMT

87

253

Sqm.

413

254

Sqm.

255

RMT

170

256

Providing and fixing storage unit to a width of 600mm and 2700mm height and as per drawing but in general, it shall be made out of 1 mm thick BWR plywood on all sides and intermediate shelves with necessary and the openable shutter shall be made out of 18mm thick exterior grade partical board for all vertical and horizontal.etc complete. All exposed and hiden surfaces shall be finished with Merino Chem+ (Lab Grade) Chemical Resistance Laminate or approved equivalent make shade. All the exposed edges of 18mm thick partical boards shall be of postformed laminate and other hiden edges are finsied with 2mm thick PVC edge band. Rate to include all hardware's, auto closing cabinet heavy duty hinges, SS handles - of approved make, including locking arrangements with master key of approved make etc. complete.(lab sample storage RGL)

RMT

38

257

Lab Counter with Storage Cabinet:Providing and fixing granite counter to a minimum width of 600 mm and to a specified height as shown in drawing(750 to 900mm) but in general, the counter top shall be made of 18mm thick water proof plywood topped with granite slab of 18 mm thick Black colour. The rate shall include for the providing storage unit below with openable shutters. The top, bottom and intermediate shelf having 18 mm thick water proof plywood with 1.5 mm thick laminate. The openable shutter shall be made of 18 mm thick BWR plywood finished with laminate including hardwares like handles,hinges, ball catches etc.complete. Rate shall be inclusive of providing SS sink with drain board, garbo drain of approved make at specified location. Rate shall be inclusive providing water supply inlet and drainage outlet for each floor as per site condition. The rate shall be inclusive of all CP sanitary accessories such as pillar cock, bottle trap, angle valve etc. of Jaguar make.

RMT

100

258

Sink and wash basin bottom covered with louvered shutter: Providing and fixing of to a specified height as shown in drawing(750 to 900mm) but in general the counter bottom frame of 75x37mm first class teak wood at top and verticals at 900mm c/c. The openable shutter shall be made of 18 mm thick BWR plywood with louvered all the exposed surfaces of ply finished with 1.5mm thick laminate including hardwares like handles, tower bolt, hinges, ball catches etc.complete. All the exposed edges of ply shall covered with teak wood lipping. Rate shall be inclusive of applying melamine polish at all the teak wood surfaces and other hidden inside surfaces are covered with sealer polish.

RMT

100

259

Providing Display unit as per drawing as directed made of 19mm thick BWR ply on all sides with open front consisting of 10mm thick tinted toughened glass shelves of 450/ 600mm width supported on to the plywood at 3 levels in height and made to shape and pattern. All exposed, internal ply surfaces shall be finished with 3.5mm thick veneer of approved shade. Rate to include providing necessary hardware's, SS studs, etc .The total height of the unit shall be 2100mm. Rate quoted shall be for the complete finished work including all the materials and labour mentioned above.( Size of display unit shall be 3000x450x2100mm) Providing and fixing book shelf storage unit to a width of 300mm and 2100mm height as per drawing but in general, it shall be made out of 19 mm thick BWR plywood on all sides and intermediate shelves with necessary and the openable shutter shall be made out of 19mm thick BWR plywood with necessary teakwood supports etc complete for bottom up to 900mm ht and above providing 6mm thick toughened glass with pivet shutter. All exposed surfaces shall be finished with 1.5 mm thick Laminate of approved shade and all inner / recessed surfaces shall have 1mm thick laminate finish of approved shade. Rate to include all hardware's, auto closing cabinet heavy duty hinges, handles - of approved make, including locking arrangements with master key of approved make etc. complete. Providing and fixing of backdrop at reception as per drawing and as directed, in general it shall be made with 12mm thick BWR ply with Acrylic sheet ONGC logo and necessary backing lighting of LED etc all as per drawing details. Total of Miscellaneous Works TOILET CUBICLES of approved make StelatexSingapore/ Merino/Greenlam Height of the door shall be 1850mm and Height of the fixed, divider shall be 2100mm.Specification as follows and refer all as per drg. And also Technical specification. (SOLID COLOUR)

RMT

260

RMT

15

261

Sqm.

25

262 a

Men's Rest Room 12mm thick HPL board with Standard necessary accessory and hardware form approved make pole base Aluminium Nylon Polyamide Accessories of approved model including Top rail of "U" channel. i)2100mm long (including 2 no of door 650mm width and fixed panel as per site condition) ii)Fixed divider panels 1500mm - 1no 12mm thick HPL board with Standard necessary accessory and hardware form approved make pole base Aluminium Nylon Polyamide Accessories of approved model including Top rail of "U" channel.

Set

263

264 a

265

266

i)1780mm long (including 2 no of door 650mm width and fixed panel as per site condition) ii)Fixed divider panels 1500mm - 1no Supplying and fixing of Urinal partition to the size of size 1290 X 500 mm made out of 12mm thick toughened glass with approved design and pattern of etching, including three sides of beveled edge polishing and finishing. The partition is to be fixed into the wall using suitable size SS brackets with anchor Bolts, Nuts, washers, grouting etc complete in all respects as directed by the Engineer-Incharge. Ladies Rest Room 12mm thick HPL board with Standard necessary accessory and hardware form approved make pole base Aluminium Nylon Polyamide Accessories of approved model including Top rail of "U" channel. i)2185mm long (including 2 no of door 650mm width and fixed panel as per site condition) ii)Fixed divider panels 1550mm - 1no 12mm thick HPL board with Standard necessary accessory and hardware form approved make pole base Aluminium Nylon Polyamide Accessories of approved model including Top rail of "U" channel. i)2550mm long (including 3 no of door 650mm width and fixed panel as per site condition) ii)Fixed divider panels 1550mm - 2no 12mm thick HPL board with Standard necessary accessory and hardware form approved make pole base Aluminium Nylon Polyamide Accessories of approved model including Top rail of "U" channel. i)1000mm long (including 1 no of door 650mm width and fixed panel as per site condition) Providing and fixing MTS Multi Trim SystemATT42/PBT12-Aluminium Top & PVC-u Base. (Providing & fixing Gradus ATT-42/12 transition plate of approved sample section of size 42mmx42mm for the junction of tiles/granite flooring with carpet. Aluminium anodised profiles shall be screwed neatly to the flooring with DowelRib screws) Providing and fixing Transition T Profile AluminiumTP291F4 ( Old type SP20AS). (Providing & fixing Gradus SP20-AS - new code TP291F4 tansition plate of approved sample section of size 20mm width for the junction of tiles/granite flooring with carpet. Aluminium anodised profiles shall be screwed neatly to the floooring with DowelRib screws) Total of Cubical Works MODULAR WORKS

Set Set

1 14

Set

Set

Set RMT

2 20

RMT

20

267

Single Person Workstation(Rockworth or approved equivalent make) of overall Size 1200 X 1500mm x 1200 H as per drawing and consisting of the following for each person: a) The work top shall be of 25mm thick exterior grade prelaminated particle board cut as per shape and design as shown in drawing. The edge of the top shall be finished with 2mm thick PVC edge banding, one no of PVC wire manager with cover matching the laminate. b) Providing & keeping in position of Pedestal Storage unit of size 450mm x 450mm x 700mm ht, it shall be made of CRC framework on three side & MDF with laminate finish on the front side with 2mm thick PVC edge banding / Postformed top surface. Storage units to have three drawers (one filing drawer and two equal drawers), with required locking system. With necessary accessories like locks, SS brush finished handle, 4nos of Nylon double wheel with locking provision and required hardware etc., c) 1 No. magnetic writing board . d) 1 No fabric Pin-up board (approved fabric costing not less than Rs. 150 / RM) e) Shall be provided with UPS / Raw Power and Data / Telephone raceways - 2 nos. 1 No. shall be provided beneath the work top and the other one shall be at floor skirting level.f) The partition shall be made of all aluminium frame finished with powder coating/anodized, covered with combination of fabric and exterior grade laminated board. Each workstation to have one writing board and a pin up board. The thickness of partition shall be 65/60 mm and the height shall be of 1200mm.g) Providing and fixing of acrylic sheet name plate holder (size 60mm wide x 300mm long)h) The end trims, top runners shall be aluminium anodized/powder coated in finish and sharp corners shall be avoided. i) Powder coated key board tray j) 1 No. Mobile CPU trolley made of CRC steel powder coated or MDF epoxy painted finish. Note: Rate to include intermediate and end partitions also as per drawings and as instructed by Engineering-in charge. Workstation size 1800x1500mm : Workstation size 2100x2600mm :

a b

Nos Nos

6 10

268

Providing and fixing of DH cabin table (Hermanmiller posh or approved equivalent make) of size 2700x1200mm side table 1600 x 600mm, made to shape and design, but the table top shall be made of 25 mm thick exterior grade prelaminated particle board with necessary supports in criss-cross manner, details as directed/ shown in dwg, and the table top and all exposed surfaces shall be finished with approved shade. Rate shall be inclusive of providing MS powdercoated articulated keyboard, 50mm dia wire manager and PVC edge banding with necessary hardwares etc., complete. 1 No. Providing & keeping in position of Pedestal Storage unit of size 450mm x 450mm x 700mm ht, it shall be made of CRC framework on three side & MDF with laminate finish on the front side with 3mm thick PVC edge banding / Postformed top surface. Storage units to have three equal drawers, with individual locking system. With necessary accessories like locks, SS brush finished handle, 4nos of Nylon double wheel with locking provision and required hardware etc.. as directed.

But the finishes shall be with veneer and melamine polish. 269 Providing and fixing of cabin table (Rockworth or approved equivalent make) of aproximate size 2400 length x 900mm, side table size 1500x600mm, made to shape and design, but the table top shall be made of 25 mm thick exterior grade prelaminated particle board with necessary supports in criss-cross manner, details as directed/ shown in dwg, and the table top and all exposed surfaces shall be finished with approved shade. Rate shall be inclusive of providing MS powdercoated articulated keyboard, 50mm dia wire manager and PVC edge banding with necessary hardwares etc., complete. Providing & keeping in position of Pedestal Storage unit of size 450mm x 450mm x 675mm ht, it shall be made of CRC framework on three side & MDF with laminate finish on the front side with 3mm thick PVC edge banding / Postformed top surface. Storage units to have three drawers(one filing drawer and two equal drawer), with individual locking system. With necessary accessories like locks, SS brush finished handle, 4nos of Nylon double wheel with locking provision and required hardware etc.. as directed. Size shall be 2100x750 and side table size 1200x600mm Size shall be 1800x750 and side table size 1050x450mm Size of the table shall be 900x600mm for sample stores

Nos Nos

6 19

270

a b c

Nos Nos Nos

53 39 8

271

Running counters:Providing and fixing counter top (Rockworth or approved equivalent make) to a width of 600 mm and 750 mm high made to shape and size shown in drawing ,using 25mm thick exterior grade prelaminated particle board with necessary bracket supports both in horizontal and vertical directions. All the edges of table top shall be provided with matching edge banding. Each person shall have one key board tray, hanging drawer unit consists of 2 drawers, using 18mm thick exterior prelaminated particle board etc with necessary hardwares and 1 No. of MS powder coated wire manager 50 mm dia. should be provided for each person and powder coated articulated metal key board / drawer unit shall run on sliding runners of approved make. ( For server, printer station etc). Storage shutters shall be made out of 18mm prelaminated particle board in. The rate shall be all inclusive of providing privacy partitions of 10mm frosted glass/ fabric wrapped panel of size 600mm wide and height 450mm as per drawing.

RMT

28

272

Running counter with partition approved equivalent make)

:(Rockworth

or

Providing and fixing of counter top of width 600mm in general it shall be made of 25mm thick exterior grade prelaminated partial board of approved shade with 2mm thick PVC edge bands, all exposed front edges of the work surfaces to be rounded. The top shall be be fixed to 69/60mm thick Partition facing outside to the corridor of workstation to be of panels of pre laminated boards of exterior grade/fire retardant fabric facing inside write on board and magnetic soft board at above table top and below table top shall be pre laminated boards of exterior grade/fire retardant fabric . The frames & caps to be of extruded aluminium sections powder coated to approved colour(not less than 50 microns thick) Trim at 1200 mm height, exposed end to be rounded Tile to glued to the frame with clip-on mechanism or set into grooves as the case may be ,but to be highly modular & elastic. The corner post of all frames to be designed for 90 degree connections in cluster of various sizes. The partitions to comprise of at least two raceways for effective wire management(one for power & other for data, one above table top & other at skirting level) With vertical raceway (If any) .The cover to be provided with necessary cutout for electrical & data socket outlets. The raceway to consist of necessary clipping mechanisms to fasten cables. Cost to include wastages mockup, all handling, transportation etc., Note: No Formaldehyde should be used in making of workstation or during placing of the work stations

RMT

273

Supplying and fixing of freestanding storage units (Rockworth or approved equivalent make), 450mm depth and 750mm height ( matching to the workstation table top height ) made of 18 mm thick both sides prelaminated particle boards of exterior grade for vertical and horizontals and intermediate shelves. The openable door shutters shall be provided with SS handles, locks, auto closing hinges and necessary hardwares etc; complete. The exposed edges shall be finished with 2mm thick PVC lipping.(rear side storage ) Storage Units: Providing and fixing rear storage unit to a width of 600mm and 750mm height as per drawing No.... It shall be made out of 25 mm thick exterior grade prelaminated board on all surfaces including top, with intermediate shelves and the openable shutter shall be made out of 18mm exterior grade prelaminated particle board laminated on both sides. Rate shall include for providing edge banding etc. complete. Rate to include all hardwares, auto closing cabinet heavy duty hinges, handles - of approved make, including locking arrangements with master key of approved make etc. complete.(meeting) Storage Units:Providing and fixing rear storage unit to a width of 450mm and 1200mm height as per drawing details It shall be made out of 25 mm thick exterior grade prelaminated board on the top and all surfaces other than the top with intermediate adjustable shelves and the openable shutter shall be made out of 18mm exterior grade prelaminated particle board laminated. All edges shall be PVC edge banded of 2mm thick on the exterior and all internal surfaces with 1mm thick PVC edge banding. Rate to include all hardwares, auto closing cabinet heavy duty hinges, handles -of approved make, including locking arrangements with master key of approved make. Storage Units: Providing and fixing rear storage unit to a width of 600mm and 1200mm height as per drawing details It shall be made out of 25 mm thick exterior grade prelaminated board on the top and all surfaces other than the top with intermediate adjustable shelves and the openable shutter shall be made out of 18mm exterior grade prelaminated particle board laminated. All edges shall be PVC edge banded of 2mm thick on the exterior and all internal surfaces with 1mm thick PVC edge banding. Rate to include all hardwares, auto closing cabinet heavy duty hinges, handles - of approved make, including locking arrangements with master key of approved make.

RMT

185

274

RMT

10

275

RMT

276

RMT

277

Storage Units: Providing and fixing rear storage unit to a width of 450mm and 2100mm height as per drawing details It shall be made out of 25 mm thick exterior grade prelaminated board on the top and all surfaces other than the top with intermediate adjustable shelves and the openable shutter shall be made out of 18mm exterior grade prelaminated particle board laminated. All edges shall be PVC edge banded of 2mm thick on the exterior and all internal surfaces with 1 mm thick PVC edge banding. Rate to include all hardwares, auto closing cabinet heavy duty hinges, handles - of approved make, including locking arrangements with master key of approved make. Storage Units:Providing and fixing rear storage unit to a width of 600mm and 2100mm height as per drawing details It shall be made out of 25 mm thick exterior grade prelaminated board on the top and all surfaces other than the top with intermediate adjustable shelves and the openable shutter shall be made out of 18mm exterior grade prelaminated particle board laminated. All edges shall be PVC edge banded of 2mm thick on the exterior and all internal surfaces with 1 mm thick PVC edge banding. Rate to include all hardwares, auto closing cabinet heavy duty hinges, handles -of approved make, including locking arrangements with master key of approved make as directed. Providing and fixing of filing compactor (Optimizer 457x 915 x 1980mm) units of Godrej or approved equivalent make as per manufacturer's specification.(all sample & record room) Providing and fixing Discussion table of circular shape of 1200mm dia, made to shape and design, but in general the table top shall be made out of 25 mm thick exterior grade prelaminated particle board over 150mm dia powder coated MS pipe with necessary supports, base and framing, and the table top and all exposed surfaces shall be finished with approved shade of 1mm thick laminate finish. Rate shall inclusive of matching edge banding with necessary hardwares etc., complete.(library & recreational block first floor)

RMT

278

RMT

279

RMT

73

280

Nos

281

Making and assembling of reading Table (Hermanmiller posh or approved eauivalent make) of specified size 1800x1200mm, made to shape and design, but in general the table top shall be made of 25 mm thick exterior grade particle board with 0.8mm thick post-formed laminate of approved shade, with adequate CRC metal supports in criss-cross manner as per your standard with modesty panel. (supporting system shall be approved by EngineerIncharge), Rate shall be inclusive of two side 2mm thick PVC edge band, cable raceway, necessary hardware's inclusive of supply and fixing of Magnum POP-up boxes as per mock up approval) etc., complete. The bottom support structure shall have openable arrangement for the purpose of easy cable management.

Nos

282

Making and assembling of Meeting Room Table (Hermanmiller posh or approved eauivalent make) of specified size made to shape and design, but in general the table top shall be made of 25 mm thick exterior grade particle board with 0.8mm thick post-formed laminate of approved shade, with adequate CRC metal supports in crisscross manner as per your standard with modesty panel. (supporting system shall be approved by EngineerIncharge), Rate shall be inclusive of two side 2mm thick PVC edge band, cable raceway, necessary hardware's inclusive of supply and fixing of Magnum POP-up boxes(required number of POP box as per mock up approval) etc., complete. The bottom support structure shall have openable arrangement for the purpose of easy cable management also the cables shall not visible. as per drawing. Table of size - 5500mm x 1200mm Specification same as above but the finishes shall be with veneer and melamine polish instead of laminate. Providing & keeping in position of Pedestal Storage unit of size 450mm x 450mm x 675mm ht, it shall be made of CRC framework on three side & MDF with laminate finish on the front side with 2mm thick PVC edge banding / Postformed top surface. Storage units to have three drawers(one filing drawer and two equal drawers), with individual locking system. With necessary accessories like locks, SS brush finished handle, 4nos of Nylon double wheel with locking provision and required hardware etc. Supplying of 1 No. Mobile CPU trolley made of CRC steel powder coated or MDF epoxy painted finish. Providing and fixing of 1 No. powder-coated metal Key board tray of size 530 (W) x 350 (D) x 40mm H with telescopic drawer slides as per drawing Nos Nos 2 1

a b

283

Nos

284 285

Nos Nos

5 5

286

Supplying and installation of dining table of size 1000x1000mm. Frame made with 12 gauge SS pipe 50mm dia for supporting leg and 25mm dia pipe for cross brazing frames shall be as per drawing. Table top shall be made with 25mm exterior grade MDF covered with 0.8mm thick post-formed laminate on 2 sides and other 2 sides finished with PVC edge band. Total of Modular Works Wardrobe Providing and fixing Wardrobe including loft as per drawing but in general, it shall be made out of 18 mm thick Particle Board of Action Tesa make or approved equivalent on all sides including top, with intermediate shelves with necessary PVC supports, finished with approved shades of Laminate. The open able shutter and shall be post formed and shall be made out of 18mm thick Particle Board and external surface shall be finished with MR Grade Laminate of Merino or approved equivalent. Rate shall include for providing matching 2mm PVC Lipping for shelves and dividers, made of Particle Board of Action Tesa make or approved equivalent ,as required. All exposed surfaces shall be finished with 1.5 mm thick laminate of approved shade and all inner / recessed surfaces shall finished with 1mm laminate. Shutter back side shall be finished with 1mm thick Laminate of approved shade.

Nos

287

Rate shall be inclusive of providing and fixing mirror on shutter as per drawing. The rate shall also include for fixing all the hardware and accessories fixing labour, electricity, all complete from Hettich / Haffele / Blum or approved equivalent. The hardware shall be inclusive of but not limited to the following hardware and accessories in Hettich or approved equivalent make-Ecomat series hinges, Garment Rails 30x15mm for required length as per drawing including supports as necessary, telescopic runner channel for drawers, locking arrangements for all internal drawers and external shutter including master key with Multipurpose Drawer Square Lock 32mm etc. complete. Note: All wire baskets, accessories, handles etc shall be of SS 304 grade. (Type C, Bachelor Units, Transit Room Wardrobes)

a b c d e

Wardrobe of size 3000x600mm x 2850mm Ht. (incl Loft) Wardrobe of size 1000x600mm x 2100mm Ht. Wardrobe for dresser unit of size 700x600mm x 2100mm Ht. Wardrobe of size 1590x500mm x 2850mm Ht. (incl Loft) Wardrobe of size 1850x600mm x 2850mm Ht. (incl Loft)

Set Set Set Set Set

64 64 64 128 28

f g h 288

Wardrobe of size 1200x600mm x 2850mm Ht. (incl Loft) Wardrobe of size 1950x600mm x 2850mm Ht. (incl Loft) RC Loft above Store (only shutters) of length 1630mm x 750mm Ht. Providing and fixing Wardrobe including loft as per drawing but in general, it shall be made out of 18 mm thick Particle Board of Action Tesa make or approved equivalent on all sides including top, with intermediate shelves with necessary PVC supports, finished with approved shades of Laminate. The open able shutter and shall be post formed and shall be made out of 18mm thick Particle Board . Rate shall include for providing matching 2mm PVC Lipping for shelves and dividers, made of Particle Board of Action Tesa make or approved equivalent ,as required. All exposed surfaces shall be finished with 1.5 mm thick laminate of approved shade and all inner / recessed surfaces shall finished with 1mm laminate. Shutter back side shall be finished with 1mm thick Laminate of approved shade. Rate shall be inclusive of providing and fixing mirror on shutter as per drawing. The rate shall also include for fixing all the hardware and accessories fixing labour, electricity, all complete from Hettich / Haffele / Blum or approved equivalent.The hardware shall be inclusive of but not limited to the following hardware and accessories in Hettich or approved equivalent make-Sensys series hinges for the wardrobes and Ecomat series hinges for the loft shutters, Garment Rails 30x15mm for required length as per drawing including supports as necessary, telescopic runner channel for drawers in Quadro Series, locking arrangements for all internal drawers and external shutter including master key with Multipurpose Drawer Square Lock 32mm etc. complete. Note: All wire baskets, accessories, handles etc shall be of SS 304 grade.(Type D and VIP Transit Rooms Wardrobes)

Set Set Set

2 12 66

a b c d e f g

Wardrobe of size 3000x600mm x 2850mm Ht. (incl Loft) Wardrobe of size 1000x600mm x 2100mm Ht. Wardrobe for dresser unit of size 700x600mm x 2100mm Ht. Wardrobe of size 1590x500mm x 2850mm Ht. (incl Loft) RC Loft above Store (only shutters) of length 1630mm x 750mm Ht. Wardrobe of size 1350x500mm x 2850mm Ht. (incl Loft) Wardrobe of size 3350x500mm x 2850mm Ht. (incl Loft and space for luggage rack and microoven as per drawing) Total of Wardrobe

Set Set Set Set Set Set Set

4 2 2 4 2 2 2

289

Crockery Unit Providing and fixing Crockery Unit including loft as per drawing but in general, it shall be made out of 18 mm thick Particle Board of Action Tesa make or approved equivalent on all sides including top, with 10mm toughened glass intermediate shelves with necessary PVC / Steel supports. The open able shutter and shall be of 10mm toughened glass with Aluminum frame. Rate shall include for providing matching 2mm PVC Lipping for vertical dividers, made of Particle Board of Action Tesa make or approved equivalent ,as required. All exposed surfaces shall be finished with 1.5 mm thick laminate of approved shade and all inner / recessed surfaces shall finished with 1mm laminate. The rate shall include for fixing all the hardware and accessories fixing labour, electricity, all complete from Hettich / Haffele / Blum or approved equivalent. Note: All wire baskets, accessories, handles etc shall be of minimum SS 304 grade. The hardware shall be inclusive of but not limited to the following hardware and accessories in Hettich or approved equivalent makeIntermat-9943 Alu Frame Hinge '0' Crank hinges including supports as necessary, Ecomat series hinges for the loft shutters, etc. complete. (Type C & Type D) Crockery Unit of size 3000x420mm x 2850mm Ht. (incl Loft) Total of Crockery Unit Set 66

290

Kitchen Providing and fixing Modular Kitchen of approved make including loft as per drawing but in general, it shall be made out of 18 mm thick BWR Ply of Action Tesa make or approved equivalent on all sides including top, with accessories, drawers and intermediate shelves as per drawings and specification with necessary PVC / Steel supports. The open able shutter and drawer front shall be post formed on 2 sides and 2 mm pvc edge banding on other 2 sides and shall be made out of 18mm thick BWR Ply and external surface shall be finished with MR Grade Laminate of Merino or approved equivalent. Rate shall include for providing matching 2mm PVC Lipping for shelves and dividers, made of 18mm thk BWR Ply of Action Tesa make or approved equivalent ,as required. All exposed surfaces shall be finished with 1.5 mm thick laminate of approved shade and all inner / recessed surfaces shall finished with 1mm laminate.

The counter top shall be finished with suitable supports and shall be made of two layers of 18mm thick BWR plywood. Rate shall be inclusive providing and fixing of SS sink with drain board of Nirali or approved equivalent make (Model: Super Slider Satin finish-850X510mm), garbo drain of approved make at specified location etc., complete. Rate shall be inclusive of making provision for fixing of Chimney hood including ducting till the external wall and exhaust outlet point, of approved make at specified location etc., complete, as directed. The rate shall include for fixing all the hardware and accessories fixing labour, electricity, all complete from Hettich / Haffele / Blum or approved equivalent. The hardware shall be inclusive of but not limited to the following hardware and accessories in Hettich or approved equivalent make-Ecomat series hinges, Intermat9943 Alu Frame Hinge '0' Crank hinges including supports as necessary, telescopic runner channel for drawers, skirting clip, etc. complete. a Type C Kitchen of size 2550x600mm x 2850mm Ht. (incl Loft) + 1800x600mm x 2850mm Ht. (incl Loft) as per drawing. Rate shall include for providing and fixing Accessories as mentioned below in Hettich or approved equivalent make-Note: All wire baskets, accessories, handles etc shall be of minimum SS 304 grade. 2 nos Wire Basket Plain with Channels, hardware and supports as required for drawer of Size 900 x 600 x Ht 325mm each with 300mm Handle 4 nos Wire Basket Plain with Channels, hardware and supports as required for drawer of Size 450 x 600 x Ht 325mm each with 150mm Handle 2 nos Wire Basket - Plate with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 300mm each with 150mm Handle 2 nos Wire Basket - Cup & Saucer with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 200mm each with 150mm Handle 2 nos Cutlery Tray with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 150mm each with 150mm Handle 1 nos Bottle Pull Out with Frame Silent H599 Silver, Frame Silent Front Angle, 2 nos Frame Baskets of 160mm each, hardware and supports as required for drawer of Size 300 x 600 x Ht 650mm each with 150mm Handle 1 nos Tall Unit with Dispensa Frame Silver 362/19002300, Dispensa Full Extension Silent 1000 N Silver, 2 nos Dispensa Front Stabilisator Silver, 5 nos Dispensa Clip-On Basket of 400mm each, hardware and supports as required for tall unit of Size 450 x 600 x Ht 2100mm each with 450mm Handle Set 64

1 nos Dish Drainer Rack Set SS 600 with shutter in cabinet of size of size 600 x 300 x Ht 650mm each with shutter, hardware and supports as required for each with 150mm Handle 6 nos Above Counter wall cabinets with 2 Flap Stay Basic in each shutter, hardware and supports as required for cabinets of size 600mm Width x 350mm Ht each with 150mm Handle 1 nos Waste Bin It Classic 13lts capacity fixed to the inside of shutter in the cabinet below the sink of size 600x 600 x Ht 650mm with shutter, hardware and supports as required for each with 150mm Handle Remaining cabinets and loft with size as per drawing with shutters, ecomat hinges, hardware and supports as required for each with 150mm Handles Bachelor Units Kitchen of size 2850x600mm x 2850mm Ht. (incl Loft) + 1000x600mm x 800mm Ht as per drawing. Rate shall include for providing and fixing Accessories as mentioned below in Hettich or approved equivalent make-Note: All wire baskets, accessories, handles etc shall be of minimum SS 304 grade. 4 nos Wire Basket Plain with Channels, hardware and supports as required for drawer of Size 450 x 600 x Ht 325mm each with 150mm Handle 2 nos Wire Basket - Plate with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 300mm each with 150mm Handle 2 nos Wire Basket - Cup & Saucer with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 200mm each with 150mm Handle 2 nos Cutlery Tray with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 150mm each with 150mm Handle 1 nos Waste Bin It Classic 13lts capacity fixed to the inside of shutter in the cabinet below the sink of size 600x 600 x Ht 650mm with shutter, hardware and supports as required for each with 150mm Handle Remaining cabinets and loft with size as per drawing with shutters, ecomat hinges, hardware and supports as required for each with 150mm Handles Transit - Common Kitchen of size 4150x600mm x 2850mm Ht. (incl Loft) as per drawing. Rate shall include for providing and fixing Accessories as mentioned below in Hettich or approved equivalent make-Note: All wire baskets, accessories, handles etc shall be of minimum SS 304 grade. 2 nos Wire Basket Plain with Channels, hardware and supports as required for drawer of Size 900 x 600 x Ht 325mm each with 300mm Handle 4 nos Wire Basket Plain with Channels, hardware and supports as required for drawer of Size 450 x 600 x Ht 325mm each with 150mm Handle

Set

28

Set

2 nos Wire Basket - Plate with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 300mm each with 150mm Handle 2 nos Wire Basket - Cup & Saucer with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 200mm each with 150mm Handle 2 nos Cutlery Tray with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 150mm each with 150mm Handle 2 nos Bottle Pull Out with Frame Silent H599 Silver, Frame Silent Front Angle, 2 nos Frame Baskets of 160mm each, hardware and supports as required for drawer of Size 300 x 600 x Ht 650mm each with 150mm Handle 1 nos Dish Drainer Rack Set SS 600 with shutter in cabinet of size of size 600 x 300 x Ht 650mm each with shutter, hardware and supports as required for each with 150mm Handle 8 nos Above Counter wall cabinets with 2 Flap Stay Basic in each shutter, hardware and supports as required for cabinets of size 600mm Width x 350mm Ht each with 150mm Handle 1 nos Waste Bin It Classic 13lts capacity fixed to the inside of shutter in the cabinet below the sink of size 600x 600 x Ht 650mm with shutter, hardware and supports as required for each with 150mm Handle Remaining cabinets and loft with size as per drawing with shutters, ecomat hinges, hardware and supports as required for each with 150mm Handles Providing and fixing Modular Kitchen of approved make including loft as per drawing but in general, it shall be made out of 18 mm thick BWR Ply of Action Tesa make or approved equivalent on all sides including top, with accessories, drawers and intermediate shelves as per drawings and specification with necessary PVC / Steel supports. The open able shutter and drawer front shall be post formed on 2 sides and 2 mm pvc edge banding on other 2 sides and shall be made out of 18mm thick BWR Ply and external surface shall be finished with MR Grade Laminate of Merino or approved equivalent. Rate shall include for providing matching 2mm PVC Lipping for shelves and dividers, made of 18mm thk BWR Ply of Action Tesa make or approved equivalent ,as required. All exposed surfaces shall be finished with 1.5 mm thick laminate of approved shade and all inner / recessed surfaces shall finished with 1mm laminate.

291

The counter top shall be finished with suitable supports and shall be made of two layers of 18mm thick BWR plywood. Rate shall be inclusive of providing and for fixing of SS sink with drain board of NIRALI or equivalent of approved make at specified location etc., complete. ( Model. No. SUPER SLIDER SATIN FINISH ) Rate shall be inclusive of making provision for fixing of Chimney hood including ducting till the external wall and exhaust outlet point, of approved make at specified location etc., complete. The rate shall include for fixing all the hardware and accessories fixing labour, electricity, all complete from Hettich / Haffele / Blum or approved equivalent. The hardware shall be inclusive of but not limited to the following hardware and accessories in Hettich or approved equivalent make-Drawers in Innotech Series, Sensys series hinges, Intermat-9943 Alu Frame Hinge '0' Crank hinges including supports as necessary, telescopic runner channel for drawers in Quadro Series, skirting clip, etc. complete. a Type D Kitchen of size 2550x600mm x 2850mm Ht. (incl Loft) + 1800x600mm x 2850mm Ht. (incl Loft) as per drawing. Rate shall include for providing and fixing Accessories as mentioned below in Hettich or approved equivalent make-Note: All wire baskets, accessories, handles etc shall be of minimum SS 304 grade. 2 nos Innotech Basket Plain with Channels, hardware and supports as required for drawer of Size 900 x 600 x Ht 325mm each with 300mm Handle 4 nos Innotech Basket Plain with Channels, hardware and supports as required for drawer of Size 450 x 600 x Ht 325mm each with 150mm Handle 2 nos Innotech Basket - Plate with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 300mm each with 150mm Handle 2 nos Innotech Basket - Cup & Saucer with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 200mm each with 150mm Handle 2 nos Cutlery Tray with Channels, hardware and supports as required for drawer of Size 600 x 600 x Ht 150mm each with 150mm Handle 1 nos Bottle Pull Out with Frame Silent H599 Silver, Frame Silent Front Angle, 2 nos Frame Baskets of 160mm each, hardware and supports as required for drawer of Size 300 x 600 x Ht 650mm each with 150mm Handle 1 nos Tall Unit with Dispensa Swing 2000-2200 B. 400 Silver, Dispensa Swing Over Extn. Silver, 2 nos Dispensa Front Stabilisator Silver, 5 nos Dispensa Clip-On Basket of 400mm each, hardware and supports as required for tall unit of Size 450 x 600 x Ht 2100mm each with 450mm Handle Set 2

1 nos Dish Drainer Rack Set SS 600 with shutter in cabinet of size of size 600 x 300 x Ht 650mm each with shutter, hardware and supports as required for each with 150mm Handle 6 nos Above Counter wall cabinets with 2 Flap Stay Basic in each shutter, hardware and supports as required for cabinets of size 600mm Width x 350mm Ht each with 150mm Handle 1 nos Waste Bin It Classic 13lts capacity fixed to the inside of shutter in the cabinet below the sink of size 600x 600 x Ht 650mm with shutter, hardware and supports as required for each with 150mm Handle Remaining cabinets and loft with size as per drawing with shutters, ecomat hinges, hardware and supports as required for each with 150mm Handles Total of Modular Kitchen Chairs (Hermanmiller posh or approved equivalent make) 292 Making and Supply of Ergonomically designed approved chairs which will meet all of the technical specifications and features listed below approved model. i)Seat:Approved color leather covered Moulded polyurethane foam together with Moulded ABS seat with revolving. ii)Back:-Approved color leather covered Moulded polyurethane foam together with Moulded ABS and extra adjustable lumber support. iii)Tilting:Synchronized tilting mechanism with revolving and multiple locking. iv)Armrests :- The armrests are to be scratch and weather resistant with swivel & deoth adjustable arm pad & option of PVC pad. v)Lifting:Gaslift provision to be provided. iv)Base:-Nylon base with 5nos of wheel pedestal should be provided as directed. High back Executive chair with HEAD REST synchronized tilting mechanism with Multiple locking systems, ABS for seat, Leather back with extra lumber Support with fine tuning for depth adjustment, with swivel & depth, Height and width Adjustable arm rest & gas lift for height adjustment, Nylon base with castors.(DH, incharge ) Nos 84

293

Making and Supply of Ergonomically designed approved chairs which will meet all of the technical specifications and features listed below approved model.i)Seat:Approved color Fire Retardant Fabric covered Moulded polyurethane foam together with Moulded ABS seat with revolving.ii)Back:-Approved color Fire Retardant Fabric covered Moulded polyurethane foam together with Moulded ABS and extra adjustable lumber support.iii)Tilting:-Synchronized tilting mechanism with revolving and multiple locking.iv)Armrests :- The armrests are to be scratch and weather resistant with swivel & deoth adjustable arm pad & option of PVC pad.v)Lifting:-Gaslift provision to be provided.iv ) Base:Nylon base with 5nos of wheel pedestal should be provided as directed. Medium Back with synchronized tilting mechanism with Multiple locking systems, ABS for seat, Mesh back with extra lumbar Support with fine tuning for depth adjustment, with fixed armrest, gas lift for height adjustment, Nylon base with castors. (Lab area and visitor to incharge meeting) AERON Medium Back with synchronized tilting mechanism with Multiple locking systems, Mesh for seat and back with extra lumbar Support with fine tuning for depth adjustment, with fixed armrest, gas lift for height adjustment, Nylon base with castors. (Conference) Medium Back visitor chair with mesh back lumber support fixed armrest with cantilever base(lab visitor, library) Supplying Breakout chairs of approved model in general it shall be made with rigid polycarbonate sheet, frame made with 20mm dia SS 16 gauge thickness pipe for legs. The chairs are to be delivered in packed condition. No damage of any sort will be accepted before taking over and chairs damaged in transit shall be replaced free of cost.Required warranty for the chairs for a period of one year shall be given.(SS 304 grade) Providing and fixing sofa (Model: SQP -Hermanmiller posh or equivalent make) made to shape and pattern as per Approved model, but in general the sofa shall be made out adequate size of teakwood frames in both horizontal and vertical directions and 2 nos. 4 mm thick plywood in curved shape portion with necessary teak wood frames and supports to shape and profile. Rate to include to provide MM foam 150mm thick, leatherite upholstery of approved make and design and ISI mark hard wares etc. complete as directed. Single seater (App. Size 900 x 825 x 800) Two seater ( App. Size 1400 x 825 x 800) Nos Nos 16 20 Nos 338

Nos

51

294

Nos

72

295

Nos

24

296

a b

297

Providing and fixing sofa side table (Model: SLO Hermanmiller posh or equivalent make) made to shape and pattern as per Approved model, side / centre table as per shape shown in the drawing made out of 19 mm thick BWR plywood as supports and at top provided with 12 mm thick tinted etched glass with bevelled edge to the specified shape and size. All exposed surface shall be finished with 3.5mm thick veneer of approved shade finish with melamine as directed. a)600x450mm b)1200x600mm Total of Chair Works External Facade and Associated Works General Note : Refer Particular specifications and Technical specification, while quoting the rate for the respective items under this schedule. Also, the BOQ item descriptions shall be read in conjunction with corresponding material specification and design criteria as specified in the tender specification as well as particular specification, in addition to the detailed specification and standards specified in the corresponding codes and standards. The quoted rate under this schedule shall be deemed to have considered Technical specification and particular specification. Nos Nos 15 7

a b

298

Vision panel, Spandrel panel & Vision on spandrel panel (System with glass): For complete system designing, providing and fixing Semi Unitized structural glazing system with aluminium anodized extruded frames, HDG brackets & SS anchors with vision panel, spandrel panel and vision on spandrel panel glass shall be Insulated Glazed unit - 24 mm thick with 6 mm thick Reflective low E coated glass on # 2 surface - Green Radiance of Asahi make or KT 455 Reflective coated glass of Saint Gobain make as outer pane and 12 mm airgap and 6 mm thick uncoated clear glass as inner pane of same make. Both panes are heat treated. Rate including supplying and fixing of glass and Off site proto type test etc. The glass will be selected at appropriate time by Engineer-Incharge. Refer Particular relevant technical Specification.

Sqm.

2300

299

Spandrel panel with ACP (System with ACP): Complete system designing, providing and fixing Semi Unitized structural glazing system with Spandrel panel having Laminated sandwiched composite panel (Aluminium composite panel) -4mm thick of approved make and colour. Refer Technical specification for detailed specification of Laminated sandwiched composite panel, which shall form part of this item. Rate shall include the cost for supplying and fixing of Laminated sandwiched composite panel with LDPE core (ACP), sealant and etc complete. Refer Particular relevant Specification.

Sqm.

300

Spandrel panel (System glass): Complete system designing, providing and fixing Semi Unitized structural glazing system with aluminium anodized extruded frames, HDG brackets & SS anchors with Spandrel panel with Single Glazed unit (Monolithic glass) - 6mm thick Reflective coated glass on # 2 surface - Super Silver Green of Asahi make or ST 467 Reflective coated glass of Saint Gobain make. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by Engineer-Incharge. Refer Particular relevant technical Specification. Hardware for top hung window: Extra rate over & above the Semi unitized structural glazing item above for designing, providing and fixing hardwares for top hung openable outward shutter as per particular specification. Rate shall exclude cost of Glass and main frame, but include cost of sub frame for shutter. Refer Particular relevant Specification. Insulation for Spandrel: Rock wool slab - 64 Kg/cum and having 'K' value of 0.033 w/Mok - 50 mm thick wrapped with factory pressed Black glass tissue and using 1.0mm thick Aluminium anodized tray with fold alround to a height of 100mm minimum as thermal insulation to be fixed behind Spandrel glass / Composite panel cladding area as mentioned. All the edges between aluminium anodized tray and frame to be sealed with Non-Staining weather silicon sealant of approved make. Refer Particular relevant technical Specification. FRAMELESS GLAZING (POINT FIXED / SPIDER GLAZING) SYSTEM.

Sqm.

301

Each

113

302

Sqm.

690

303

Frameless glazing system with Tensile Cable net / truss frame: Complete system for Frame less glazing with Cable truss / net system as mentioned in Particular Specification. Rate shall include cost of spiders suitable for laminated single / double glazed unit, Articulated bolts, required dia double / single stand SS pre tensioned cables to satisfy the structural criteria, off site proto type test etc,.

Frameless glazing system with Laminated DGU: Frame less glazing system with supplying and fixing of 33.52 mm thick (13.52mm + 12mm Air gap + 8mm) Laminated Double glazed unit having 13.52 mm thick with 6mm thick Reflective low E coated Grey Lite of Asahi make or Green Radiance of Asahi make or KT 455 Reflective coated glass of Saint Gobain make as outer panel and 6 mm thick uncoated clear glass as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of DuPont make + 12 mm Air gap + 8mm thick uncoated clear glass of same make. All glass panels shall be heat treated and heat soak tested. Refer Particular relevant technical Specification. Frameless glazing system with Laminated glass: Frame less glazing system with supplying and fixing of 19.52 mm thick laminated glass having 10 mm thick as outer panel and 8 mm thick as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of DuPont make. Outer pane glass shall be Reflective coated glass on # 2 surface Pebble Blue Grey of Asahi make or Super Silver Green of Asahi make or ST 467 of Saint Gobain make. Inner pane shall clear glass and both panes shall heat treated and heat soak tested. Refer Particular relevant technical Specification. Frameless glazing system with Glass Fin: Complete system for Frameless glazing as mentioned in Particular Specification. Rate shall include cost of spiders, Articulated bolts and supply and fixing the Glass fin with required size to satisfy the structural criteria and rate shall exclude the cost of Off site proto type test. The thickness of glass fin shall be 21.52mm thick (Min) laminated toughened and heat soak tested as per specification. Frameless glazing system with Laminated DGU: Frame less glazing system with supplying and fixing of 33.52 mm thick (13.52mm + 12mm Air gap + 8mm) Laminated Double glazed unit having 13.52 mm thick with 6mm thick Reflective low E coated Grey Lite of Asahi make or Green Radiance of Asahi make or KT 455 Reflective coated glass of Saint Gobain make as outer panel and 6 mm thick uncoated clear glass as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of DuPont make + 12 mm Air gap + 8mm thick uncoated clear glass of same make. All glass panels shall be heat treated and heat soak tested. Refer Particular relevant technical Specification.

Sqm.

425

Sqm.

304

Sqm.

110

Frameless glazing system with Laminated glass: Frame less glazing system with supplying and fixing of 19.52 mm thick laminated glass having 10 mm thick as outer panel and 8 mm thick as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of DuPont make. Outer pane glass shall be Reflective coated glass on # 2 surface Pebble Blue Grey of Asahi make or Super Silver Green of Asahi make or ST 467 of Saint Gobain make. Inner pane shall clear glass and both panes shall heat treated and heat soak tested. Refer Particular relevant technical Specification. System for Standard Sliding Door: Providing and fixing the Standard sliding door with ES 200 operator with ST Flex profile with both side fixed panel of Dorma make or EC Drive operator with ST Flex profile with both side fixed panel of Geze make with the required structural support. Rate shall include the cost for supplying and fixing 12.52 mm thick laminated glass having 6 mm thick as outer panel and 5 mm thick as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of DuPont make. Outer pane glass shall be reflective coated glass Sunergy Clear of Asahi make or ST 167 of Saint Gobain make. Inner pane shall be uncoated clear glass and both panes shall be heat treated and heat soaked. All MS members shall be painted with anti corrosive, low VOC PU paint (metallic finish) with compatible primer to a minimum film thickness of 75 microns and 2 coats of low VOC PU paint of Akzonoble make and total dry film thickness 225 microns. (If MS work is involved) Refer Particular relevant technical Specification.

Sqm.

305

Sqm.

13

306

Providing and fixing colour anodized aluminium Pivoted Double leaf / Single leaf door with openable side hung shutter as per drawing and fixed at all levels, elevations and heights. Rate shall include the cost of Necessary hardwares, accessories as given in the particular specification and supplying and fixing og glass as given below. Refer Particular relevant technical Specification. Openable swing door with Insulated Glass - 24 mm thick with 6 mm thick Reflective low E coated Grey Lite of Asahi make or Green Radiance of Asahi make or KT 455 Reflective coated glass of Saint Gobain make as outer pane and 12 mm airgap and 6 mm thick uncoated clear glass as inner pane of same make. Both panes are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by EngineerIncharge. Single Leaf door Double Leaf door

a b

Sqm. Sqm.

10 20

307

Designing, providing and fixing Aluminium Twin Style Double leaf / Single leaf door with openable side hung shutter with Top & Bottom rails TP/TA of Dorma make or Geze make. Rate shall include the cost for supply & fixing of hardwares like Floor spring, Handle and Lock etc with necessary accessories etc and supplying & fixing 12.52 mm thick laminated glass having 6 mm thick as outer panel and 5 mm thick as inner panel with interlayer of 1.52 mm thick Sentry Glas (R) of Dupont make. Outer pane glass shall be reflective coated glass -Sunergy Clear of Asahi make or ST 167 of Saint Gobain make. Inner pane shall be uncoated clear glass and both panes shall be heat treated and heat soaked. Refer particular specification for type and make of hardwares to be considered for tender quote. Refer Particular relevant technical Specification.

a b 308

Single Leaf door Double Leaf door Providing and fixing Fixed cum Openable windows with Aluminium anodized frames of Schuco / Kawneer make or approved equivalent make with Specified glass below and fabricated as per drawing and fixed at all levels. Rate shall include the cost of Necessary hardwares for openable shutter and fixed panels, aluminium colour anodized subframe, accessories and supplying and fixing of glass. Refer Particular relevant technical Specification. Fixed cum Openable windows with Monolithic Glass 6 mm thick Reflective coated glass on # 2 surface - Super silver Green of Asahi make or ST 467 Saint gobain make. All panels are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by Engineer-Incharge. Fixed cum Openable windows with Monolithic Glass 6 mm thick Reflective coated glass on # 2 surface - Pebble Blue Grey of Asahi make or Super silver Green of Asahi make or ST 467 Saint gobain make. All panes are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by EngineerIncharge. Providing and fixing Fixed cum Sliding windows with Aluminium anodized frames of Schuco / Kawneer make or approved equivalent make with Specified glass below and fabricated as per drawing and fixed at all levels. Rate shall include the cost of Necessary hardwares for sliding shutter and fixed panels, aluminium colour anodized subframe, accessories and supplying and fixing of glass. Refer Particular relevant technical Specification.

Sqm. Sqm.

5 12

Sqm.

170

Sqm.

1535

309

Fixed cum Sliding windows with Insulated Glass -24 mm thick with 6 mm thick Reflective low E coated Grey Lite of Asahi make or Green Radiance of Asahi make or KT 455 Reflective coated glass of Saint Gobain make as outer pane and 12 mm airgap and 6 mm thick uncoated clear glass as inner pane of same make. Both panes are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by EngineerIncharge. Fixed cum Sliding windows with Monolithic Glass 6 mm thick Reflective coated glass on # 2 surface -Super silver Green of Asahi make or ST 450 Saint gobain make. All panes are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by Engineer-Incharge. Fixed cum Sliding windows with Monolithic Glass 6 mm thick Reflective coated glass on # 2 surface -Pebble Blue Grey of Asahi make or Super silver Green of Asahi make or ST 467 Saint gobain make. All panes are heat treated. Rate including supplying and fixing the glass. The glass will be selected at appropriate time by Engineer-Incharge. Laminated sandwiched composite panel cladding and Associated works

Sqm.

70

Sqm.

255

Sqm.

10

310

Dry wall cladding : Providing and fixing the system to clad the Laminated sandwiched composite panel of Alucobond or Alubond or Durabuild or Aludecor make with approved colour and shade (4 mm (0.5 + 3.0 + 0.5) ACP with Mineral core / polyethylene 100% Virgin Core) as per the specification described in Technical specifications, on the external surface the external surface like column, wall, jambs, sills, projected area, ceiling or any surface to any profile and shape, horizontally, vertically, sloped, curved, circular etc complete. Rate shall include the cost of supplying and fixing of Laminated sandwiched composite panel (ACP with Mineral core / polyethylene 100% virgin Core), Non staining weather for Vertical & horizontal joints in general the frame work for ACP cladding consists of aluminium box frame with 'C' cleat frame on the Box frame with HDG bracket etc, complete. All anchors, bolts and screws shall be SS 316 grade of Hilti / Fischer make. Refer Particular relevant technical Specification.

Sqm.

1500

311

Canopy / Pergola cladding: Designing, Providing and fixing the system to clad the Laminated sandwiched composite panel of Alucobond or Alubond or Durabuild or Aludecor make with approved colour and shade (4 mm (0.5 + 3.0 + 0.5) ACP with Mineral core / polyethylene 100% Virgin Core) as per the specification described in Technical specifications for Canopy, screen wall, fin and Pergola as per profile and shape shown in the Drawing with necessary Hot dip Galvanized Structural steel support to clad the ACP and all support to be designed to withstand the Design wind pressure and the specification specified in Particular specifications etc complete. Main structural steel support will be measured under respective item separately.

Rate shall include the cost of supplying and fixing of Laminated sandwiched composite panel (ACP with Mineral core / polyethylene core), Non staining weather for Vertical & horizontal joints in general the frame work for ACP cladding consists of aluminium box frame with 'C' cleat frame on the Box frame with HDG bracket etc, complete. All anchors, bolts and screws shall be SS 316 grade of Hilti / Fischer make. Refer Particular relevant technical Specification. NOTE :Main structural steel frame work for Canopy, screen wall, fin and Pergola to clad the canopy with ACP shall be measured under respective Items, but the aluminium frame work and supporting bracket required for cladding shall be part of the rate quoted under this item. 312 Providing and applying Cold Bituminous coating (Vapour barrier) on the External wall behind Composite panel / Granite cladding area etc. Refer Particular relevant technical Specification. Providing and fixing aluminium extruded louver "Z" type as described below and to be designed to with stand the design wind pressure. Refer Particular relevant technical Specification. Support system to fix the Louver:Complete system having colour anodized aluminium box frame, aluminium base plate and aluminium angles etc.Note : Weight will be considered only for the assembled frame part and hence necessary wastage shall form part of the rate quoted. Fixed Louver: Providing and fixing Storm proof louver "Z" type made out of specially extruded aluminium with anodized finish and as specified in Particular specifications and to be fixed with pitch not less than 50 mm and overlapping shall be 25 mm as minimum as shown in the drawing.

Sqm.

5775

Sqm.

1530

313

Kg

795

Sqm.

105

314

Providing and fixing Luxalon SL - 4 Stringer with 84R plain Louvers panel of Hunter Douglas make or equivalent Fameline make with Luxacote finish and the louver system shall be designed to with stand the design wind pressure. Rate shall include louver Panel, Carrier, Carrier Splice, Panel Splice and accessories etc. Refer Particular relevant technical Specification. Providing and fixing Aluminium Grille of Fameline make with specified product code as below PVDF finish and the louver system shall be designed to with stand the design wind pressure with pitch not less than 75 mm as shown in the drawing. Louver thickness not less than 0.8mm. Rate shall include louver Panel, aluminium frames, aluminium end caps, aluminium brackets / clamps, SS anchors, bolts and accessories etc. Refer Particular relevant technical Specification. Product code 2050RT Product code 1050RT Dry wall granite cladding: Quote rate for providing and fixing Granite slab - Dry type fixing using approved colour granite slab (Basic cost of Granite not less than Rs.140/- per sq.ft) cladding the external surface on any surface to any profile and shape, horizontally, vertically, sloped, curved, circular etc with approved shade of Granite thickness not less than 25 mm thick and as per the sizes shown in the Drawing etc complete and as directed. (On the Facade areas). Granite shall be fixed with a groove of 6mm and to be filled with weather sealant recessed by 2mm. Refer Particular relevant technical Specification. Projection in line with Faade finishes as per drawing. Projection upto 75 mm from the Main base structure. Providing dadoing with machine cut and machine high Pre-polished best quality granite tile of approved colour and shade with thickness not less than 12 mm of size 600x300 mm, set in C.M. 1:3 of 20mm thick, including pointing with matching cement and fixing with stainless steel clamps with suitable size at two ends to right angle by using SS anchor fastners and SS pin, the former with horizontal position to be embedded in brick wall/concrete surface and the later with vertical position to be inserted and caulked in to the holes of the slab, drilled for the purpose, both forming 'T' shape and cement grouted including edge polishing wherever required and forming groove at joints as directed at all levels. Rate shall include for preparation of base surface, SS clamps, SS anchor fastner, cleaning, chamfering, edge polishing, acid wash and protection etc. complete, as directed.

Sqm.

10

315

a b 316

Sqm. Sqm.

1600 10

a b 317

Sqm. Sqm. Sqm.

30 10 10

318

Supplying and fixing of 16mm thick Multi wall insulated polycarbonate sheet roof cladding on the Structural steel frame structure at all levels as per pattern for sky Light Roof including single skin - 10 mm thick insulated poly carbonate sheet capping & specials with necessary aluminium extrusion, cutting, fabricating, erection at all levels as specified in the particular specification. Rate shall include the cost of all materials involved in this item like poly carbonate sheet and accessories etc. Rate shall exclude the cost of base M.S structural base supports shall be measured separately under respective item specified above. Refer Particular relevant technical Specification.Note : Surface area will be measured and paid for. Providing and fixing 3M tape (Code No: 4412N Translucent white) of approved type and pattern with minimum 50 mm wide in addition to the Sealant at the desired location. 3M Tape shall be provided as per manufacturer specification and methodology. Providing and applying over the granite / stone surface one coat of environment friendly silicon based Water Repellent as per manufacturers specification with no undulations and waviness as per the specification as directed by Engineer-Incharge. Total of External Facade and Associated Works

Sqm.

395

319

Rmt

100

320

Sqm.

50

321

Facade Access System Operating System Design, supply, install and commission Facade Access system with the following equipments to make sure that the entire facade will be cleaned with the proposed system and to reach any shape and profile and the system shall with stand a minimum design wind pressure of 200 Kg/sqm conforming to IS 875-Part 3 and Lateral forces as per IS 1893 (Latest Revision) and the system support at parapet wall as specified.Bidderr shall be responsible to determine the maximum design wind pressure and lateral forces, moments, stresses etc. applicable for the system. Negative / suction pressures if determined as per IS 875 part - 3 and Lateral forces as per code IS 1893 shall make allowances as described in the code for corner effects on the system. Quoted rate shall include the following, but not limited to a) Designing the system, preparation of shop drawing for approval, supply, fabricate, erect as per approved drawing at all levels, elevation & heights including conducting necessary test according to the codes etc complete. b) In general, system comprising, Traverse Trolley (Permanent) system with two manual gondola and which shall suspend Standard 2 Metre long cradle with Imported wire ropes and winches.

c) Supply & Install the necessary supporting brackets with SS anchor bolts,etc complete. d) All support system necessary for installation including scaffolding, hoists, minor civil works and any other works equipment related thereto for complete installation of the system as per specification and approved shop Drawing. e) Supply and anchoring the Soffit / Face mounted brackets at a minimum spacing specified elsewhere in the straight / curved portion and extra bracket if any required at corners / projected area shall be provided with hot dip galvanized steel anchor bolt assemblies with base Plates. f) Providing and anchoring brackets with suitable dia of Hilti make Anchor bolts permanently on the wall ceiling as specified in the approved shop drawing. g) Obtain & submit certification of design by independent professional engineer / consultant along with final design and shop drawings. h) Manufacture / fabrication, transport and handling, installation / fixing, testing, commissioning and Insurance. i) Taxes, Duties, levies and imparting training to owners representatives in operation and maintenance of the system. j) Rate shall included for maintenance of the all systems as specified in the conditions of contract during the defects liability period. k) Rate shall deemed to be included the above stipulated provision. Hot dip galvanized Parapet mounted combination bracket (Upper and Lower Brackets) of suitable size and Long and to be fixed at a required spacing as per design with suitable dia & type of SS 316 grade anchor fasteners at specified locations including grouting the surface with all other accessories etc complete. Hot dip galvanized Hot rolled sections"I"Beam of 200 x 100 mm or suitable size (Size given is indicative and the bidder shall confirm the size of member based on structural requirements) and to be fixed on the Upper and Lower brackets with suitable dia & type of SS 316 grade bolts at specified locations including grouting the surface with all other accessories etc complete. Aluminium Swivel traverse trolley (Permanent) and to be fixed on the Upper and Lower Beams to manually operate the system at specified locations with all other accessories etc complete. (Each set containing 2 Arm) Accessible System Providing and fixing of Cradle platform with complete system, the type and capacity given below and in general the cradle made out Aluminium tubes with Frame work and in accordance with the technical specification and drawing.

No.

20

RMT

50

Set

322

a b

Standard - 2 Metre Cradle platform with all other accessories etc complete. Providing and fixing Imported Aerial work platform with complete system and the working height of 21 M and above and in accordance with the technical specification and drawing. Providing and fixing Imported Electro Hydraulic elevated Vertical platform with complete system and the working height of 16M and above and in accordance with the technical specification and drawing. Total of 'Facade Access System ELECTRICAL WORKS SECTION-A: TRANSFORMERS AND HT BREAKERS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Ring Main Switichgear (Indoor) - 11KV Design, Supply, Installation, Testing and Commissioning of INDOOR Weather & Dust proof Type, floor mounting, free standing 11kV Ring Main Gear unit made out of M.S sheet steel clad dust and vermin proof with 630A Copper Busbars, Interconnections, necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs, Termination arrangements for Incoming and Outgoing Cable of 11 kV 3Core 185 Sq mm XLPE Alu.Armoured earthed cable, Terminal Blocks, Earthing,Powder coated painting, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed Technical Specifications enclosed and as per EB Requirements comprising of the following. INCOMER (2 Sources) : 11kV, 630A, 500MVA LOAD Break Switch (Air Break ) with necessary required accessories -2Nos OUTGOING : 11kV, 630A, 500MVA VACCUM Circuit Breaker with necessary required accessories : 1No The RMG panel shall be manufactured as required by the electrical authorities and approval shall be obtained including testing & commissioning and any additional features required by the supply authorities shall be carried out at no extra cost.

No. No.

1 1

No.

323

No.

324

Design, supply, installation, testing and commissioning of 11KV 630A, 500MVA, 26.2kA VCB Breaker HT indoor three Panel Board with all accessories and allmetreing protection for satisfactory operation and as required by the statutory Electrical authorities as per the detailed specification enclosed. Design, supply, installation, testing and commissioning of 1250KVA, 11kV/433V outdoor, Oil cooled Transformer with on load tap changer & RTCC panel as per the detailed specification enclosed. Transformer Protection relays should be provided at each Transformer such as Transformer Buchholz relay, restricted earth fault relay,OLTC surge relay, Oil temperature relay, winding temp relay, Auxiliary relays as per standards. The transformer shall be provided with cable termination box on HT side to terminate 3 core 185 Sqmm XLPE cableand suitable for terminating air insulated aluminium busduct on LT side 2000A Amps rating all as per the detailed specification enclosed. (THE TRANSFORMER SHALL BE SUPPLIED WITH FIRST FILL OF OIL)

No.

325

Nos.

326

Design, supply, laying, testing and commissioning of 3 core 185 sqmm 11KV, XLPE Aluminium conductor individual core screened, flat steel strip armoured, PVC sheathed cable inside the building in the prepared trench/under ground (from 11KV RMG to outdoor HT VCB panel, HT indoor VCB panel & Transformer) HT Terminations: Design, supply, termination, testing and commissioning of OUTDOOR type termination kit and accessories suitable for 11KV, 3 core 185 Sqmm XLPE cable. Design, supply, termination, testing and commissioning of INDOOR type termination kit and accessories suitable for 11KV, 3 core 185 Sqmm XLPE cable. Design, supply, erection, testing and commissioning of 2000 Amps outdoor type air insulated Aluminium FP busduct with flexible joints at every 4.5Mtr. Interval (RYBN) and with suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. Horizontal and vertical bends. (The busduct shall be Aluminium busbars of suitable size. The busbar should be support by epoxy insulators at regular intervals) The busduct shall run from Transformer secondary and DG to MPCC. The bus duct shall be fabricated as per the detailed specification enclosed. Current Density of busbars shall not exceed 0.8 Amps/ Sq.mm.

RMT

100

327

No.

328

No.

329

RMT

60

330

Design, supply, erection, testing and commissioning of 2000 Amps indoor type air insulated Aluminium FP busduct with flexible joints at every 4.5Mtr. Interval (RYBN) and with suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. Horizontal and vertical bends. (The busduct shall be Aluminium busbars of suitable size. The busbar should be support by epoxy insulators at regular intervals) The busduct shall run from Transformer secondary and DG to MPCC. The bus duct shall be fabricated as per the detailed specification enclosed. Current Density of busbars shall not exceed 0.8 Amps/ Sq.mm. Design, supply, erection, testing and commissioning of 1250 Amps indoor type air insulated Aluminium FP busduct with flexible joints at every 4.5Mtr. Interval (RYBN) and with suitable support from ceiling as per the detailed specification enclosed. The busduct should be with straight run, 90 deg. Horizontal and vertical bends. (The busduct shall be Aluminium busbars of suitable size. The busbar should be support by epoxy insulators at regular intervals) The busduct shall run from MPCC to Capacitor Panel. The bus duct shall be fabricated as per the detailed specification enclosed. Current Density of busbars shall not exceed 0.8 Amps/ Sq.mm.

RMT

66

331

RMT

24

332

333

334

335 336 337 338

339

Design, supply, erection, testing and commissioning of Battery Charger 110V DC 100 AH Trip unit combined with trickle & boost charge facilities with battery bank(SMF) & Distribuition Board and as per the detailed specification / drawing enclosed. Removing the existing indoor HT RMG Panel (630A LBS as incomer and 630A VCB as outgoing) and existing HT Cables and handing over to customer Removing the existing indoor HT Panel (630A VCB as incomer and 630A LBS-2Nos as outgoings) and existing HT Cables and handing over to customer Removing the existing Transformer and HT Cables and handing over to customer Removing the existing LT Main Panel and incoming LT Cable and handing over to customer Removing the existing Emergency LT Panel and incoming LT Cable and handing over to customer Removing & re-laying the existing LT cables with terminations from LT Main Panel & Emergency LT Panel (12 runs of cables, 1R-3.5Cx240, 7R-3.5Cx185, 2R-4Cx16, 2R-3.5Cx35), 10mtr length (approx) Removing the existing capacitor bank and LT Cable and handing over to customer SECTION B : LT PANEL BOARDS All installation works should be as complete and as directed by Engineer-Incharge.

No.

No.

No.

Nos. Nos. Nos. LS

1 1 1 1

Nos.

The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Note: All themetres Should be provided with RS 485 BMS integration. All themetres should be connected in series thro' bus cable terminated at commonmetre chamber 340 Design, supply, erection, testing and commissioning of cubicle type floor mounting main power control centre made out of MS sheet enclosure with Aluminium busbars, single busbar system, cable chamber, interconnection, painting, earthing, protection relays etc. comprising of the following : (MPCC) INCOMING EB Incomer 2 Nos. 2000 Amps 4 Pole 65KA electrical draw out type Air circuit breaker with shunt release shutter assembly, door interlock and all other accessories. Instruments Panel Digital type Ammeter & Voltmeter, Maximum demand controller, Instantaneous earthfault relay (2 O/C+ 1 E/F), Low set earth fault relay (51G), CTs control fuses, RYB Indication lamps and ON/OFF/Trip" indicating lamp in each incomer, and also refer the drawing. The rate shall be inclusive of neutral CT connected with E/F Relay & space Heater DG Incomer 2 Nos. 2000 Amps 4 Pole 65KA electrical draw out type Air circuit breaker with shunt release shutter assembly, door interlock and all other accessories. Instruments Panel Digital type Multifunctionmetre, CTs control fuses, RYB Indication lamps and ON/OFF/Trip" indicating lamp in each incomer, and also refer the drawing. Buscoupler 1No.2000 Amps 4 pole 65KA electrical draw out type Air circuit breaker with shunt release, shutter assembly, door interlock and all other required necessary accessories and ON/OFF lamps. The buscoupler shall be provided with mechanical & electrical Inetrlocking arrangements. OUTGOINGS 1250A 4P MDO ACB, 50 KA 4Nos 800A 4P MCCB, 50 KA 4Nos 630A 4P MCCB, 50 KA 5Nos 400A 4P MCCB, 50 KA 6Nos

All the Outgoing feeder should be ON/OFF/Trip indication lamps, Digital type Multifuctionmetre(Except capacitor feeder which is provided with Ammeter), CTs,Fuse, Switch control,Front operting handles etc. All switch boards shall be fabricated as per the detailed specification enclosed. Suitable size outgoing cable chamber and extra busbars should be provided for connecting the number of outgoing cables as per the schematic drawing. Additional NO + NC contact should be provided for BMS monitoring. All the NO+NC contact wiring should be terminated on commonmetre chamber. The board shall be fabricated for future extension of the panel board. The transformers incomer shall be provided with protection relays such as IDMT (2 O/C +1 E/F), Maximum demand controller, REFR (Restricted Earth fault Relay),etc., and bus coupler shall be both mechanical and electrical interlocking arrangements by hardware control wiring alongwith PLC (Programmable Logic Controls). The Hardware control wiring & PLC operation shall be feasible to extend for future Transformer if any and all as per the detailed specification and drawings enclosed. This incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. Incomingmetre for Transformer shall be with demand controller , Harmonic THD and individual harmonic display+ Regular parameters like V, I, KVA, KVAR, KW, KWH, KVARh, PF, Freq, Max, AVG Incomingmetre for Generator shall be with Load monitoring without demand control and with regular parameter & Harmonics THD & Individual harmonic display All Outgoing Feeders in Main panel shall be with MFM monitoring V,I, KWH, KVARH, PF with RS 485 BMS integration. All themetres to be connected in series thro' bus cable terminated at commonmetre chamber Main Power Control Centre (MPCC) 2000Amps 4P Aluminium busbars:- All the neutral busbars shall have the same capacity of phase busbars.(0.8A/Sq. mm.) 341 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (APFCR Panel) Incoming 1250A TP MDO ACB 50 KA Drawout type with Auto power factor correction relay with necessary CT, control wiring etc.- 1 No. as incomer. Outgoing: Total 425 KVAR

No.

2 sets of 100 KVAR (4 x 25 KVAR) with 400A TP MCCB 35KA, suitable contactors with switching steps in the rating of 100 KVAR as required. 3 sets of 50 KVAR (2 x 25 KVAR) with 200A TP MCCB 25KA, suitable contactors with switching steps in the rating of 50 KVAR as required. 3 sets of 25 KVAR (1 x 25 KVAR) with 100A TP MCCB 16KA, suitable contactors with switching steps in the rating of 25 KVAR as required. Each All KVAR capacitor bank in a separate compartment with necessary ventilation arrangemnts or weld mesh arrangements as required by the Electrical Authorities . With necessary Aluminium busbars, interconnections, providing Ammeter with selector switches, phase indication lamp, control fuse and switch control, PFmetre etc. with RS 485 BMS integration as per the specification. Capacitor Panel - 425 kVAR 1250 Amps TPN Aluminium busbars:- All the neutral busbars shall have half the capacity of phase busbars (0.8A/Sq. mm) 342 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (Utility Panel) INCOMING 250A 4P MCCB 25 KA with connected accessories 2Nos.as incomer with 2 lock and 1 key mechanical interlock arrangement OUTGOINGS 63A TPN MCCB, 16 KA 3Nos 32A TPN MCCB, 16 KA 5Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 250A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.) Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. SUB SWITCH BOARD-1 (OFFICE AREA) INCOMING 1250A TP&N MDO ACB 50 KA Drawout type with connected accessories 1No.as incomer OUTGOINGS

Nos.

No.

343

800A TPN MCCB, 50 KA 2Nos 630A TPN MCCB, 35 KA 1No 400A TPN MCCB, 35 KA 1No 200A TPN MCCB, 25 KA 1No With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 1250A Amps TPN Aluminium busbars : All the neutral busbars shall have half the capacity of phase busbars (0.8A/Sq. mm.). 344 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. SUB SWITCH BOARD-2 (OFFICE AREA) INCOMING 1250A TP&N MDO ACB 50 KA Drawout type with connected accessories 1No.as incomer OUTGOINGS 800A TPN MCCB, 50 KA 2Nos 630A TPN MCCB, 35 KA 1No 400A TPN MCCB, 35 KA 2Nos 200A TPN MCCB, 25 KA 1No With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 1250A Amps TPN Aluminium busbars : All the neutral busbars shall have half the capacity of phase busbars (0.8A/Sq. mm.). 345 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LIGHTING POWER SWITCH BOARD -REGIONAL STORE INCOMING 125A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA 5Nos 32A TPN MCCB, 16 KA 8Nos

No.

No.

With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 346 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LIGHTING POWER SWITCH BOARD -RECREATIONAL BLOCK INCOMING 125A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA 3Nos 32A TPN MCCB, 16 KA 5Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 347 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. POWER PANEL RECREATIONAL BLOCK INCOMING 250A TPN MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 125A TPN MCCB, 25 KA 2Nos 63A TPN MCCB, 16 KA 1No. 32A TPN MCCB, 16 KA 7Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing.

No.

No.

The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 250A Amps TPN Aluminium busbars : All the neutral busbars shall have half the capacity of phase busbars (0.8A/Sq. mm.). 348 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-1) LIGHTING POWER SWITCH BOARD - TYPE-C&D INCOMING 100A 4P MCCB 16 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA + KWHmetre 2Nos 32A TPN MCCB, 16 KA + KWHmetre 2Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 349 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-2,8,14 &18) LIGHTING POWER SWITCH BOARD - TYPE-C&D INCOMING 125A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA + KWHmetre 5Nos 32A TPN MCCB, 16 KA + KWHmetre 1Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration

No.

No.

125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 350 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-3, 4 to 7, 9 to 13 & 15 to 17) LIGHTING POWER SWITCH BOARD - TYPEC&D INCOMING 125A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA + KWHmetre 5Nos 32A TPN MCCB, 16 KA + KWHmetre 1Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 351 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LIFT PANEL - TYPEC&D + BACHELOR & TRANSIT INCOMING 125A 4P MCCB 16 KA with connected accessories 2Nos.as incomer with 2 lock and 1 key mechanical interlock arrangement OUTGOINGS 32A TPN MCCB, 16 KA + KWHmetre 6 Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.).

Nos.

Nos

13

Nos.

352

Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-1) LIGHTING POWER SWITCH BOARD - BACHELOR & TRANSIT INCOMING 100A 4P MCCB 16 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA + KWHmetre 3Nos 32A TPN MCCB, 16 KA + KWHmetre 4Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.).

No.

353

Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-3 to 12) LIGHTING POWER SWITCH BOARD - BACHELOR & TRANSIT INCOMING 100A 4P MCCB 16 KA with connected accessories 1No.as incomer OUTGOINGS 32A TPN MCCB, 16 KA + KWHmetre 6Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.).

Nos

10

354

Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LPSB-2) LIGHTING POWER SWITCH BOARD - TYPE-C&D

INCOMING 100A 4P MCCB 16 KA with connected accessories 1No.as incomer OUTGOINGS 32A TPN MCCB, 16 KA + KWHmetre 4Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 355 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (LSB-1) LIGHTING SWITCH BOARD -(OFFICE AREA) INCOMING 100A 4P MCCB 16 KA with connected accessories 1No.as incomer OUTGOINGS 32A TPN MCCB, 16 KA 4Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 356 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (PSB-1) POWER SWITCH BOARD -1 (OFFICE AREA) INCOMING 125A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA 4Nos 32A TPN MCCB, 16 KA 2Nos

No.

No.

With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 357 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (PSB-2) POWER SWITCH BOARD -2 (OFFICE AREA) INCOMING 630A 4P MCCB 35 KA with connected accessories 1No.as incomer OUTGOINGS 100A TPN MCCB, 16 KA 7Nos 63A TPN MCCB, 16 KA 9Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 630A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 358 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (PSB-3) POWER SWITCH BOARD -3 (OFFICE AREA) INCOMING 400A 4P MCCB 35 KA with connected accessories 1No.as incomer OUTGOINGS 100A TPN MCCB, 16 KA 1No. 63A TPN MCCB, 16 KA 11Nos 32A TPN MCCB, 16 KA 8Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing.

No.

No.

The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 400A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 359 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (PSB-4) POWER SWITCH BOARD -4 (OFFICE AREA) INCOMING 200A 4P MCCB 25 KA with connected accessories 1No.as incomer OUTGOINGS 63A TPN MCCB, 16 KA 5Nos 32A TPN MCCB, 16 KA 9Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 200A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 360 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. LIFT PANEL - OFFICE AREA INCOMING 125A 4P MCCB 25 KA with connected accessories 2Nos.as incomer with 2 lock and 1 key mechanical interlock arrangement OUTGOINGS 63A TPN MCCB, 16 KA 2Nos 32A TPN MCCB, 16 KA 2Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration

No.

No.

125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.). 361 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (UPS O/G PANEL) UPS O/G PANEL -OFFICE AREA INCOMING 630A TP+2N MCCB 35 KA with connected accessories 2 Nos as incomer OUTGOINGS 630A TP+2N MCCB 35 KA with connected accessories 2 Nos as incomer With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 630A Amps TP+2N Aluminium busbars (0.8A/Sq. mm.). 362 Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (AC PANEL ) OFFICE AREA INCOMING 125A 4P MCCB 25 KA with connected accessories 1 No.as incomer OUTGOINGS 100A TPN MCCB, 16 KA 1No. 63A TPN MCCB, 16 KA 4Nos 32A TPN MCCB, 16 KA 6Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 125A Amps 4P Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.).

No.

Nos.

No.

363

Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (EMERGENCY LIGHTING PANEL ) -OFFICE AREA INCOMING 100A TP+2N MCCB 16 KA with connected accessories 1 No.as incomer OUTGOINGS 32A TPN MCCB, 16 KA 8Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 100A Amps TP+2N Aluminium busbars : All the neutral busbars shall have the same capacity of phase busbars (0.8A/Sq. mm.).

No.

364

Design, supply, fixing, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. (SSB) -SUBSWITCH BOARD FOR EXISTING RESIDENCE INCOMING 800A TP+N MCCB 25 KA with connected accessories 1 No.as incomer OUTGOINGS 400A TPN MCCB, 16 KA 4Nos 250A TPN MCCB, 16 KA 4Nos 63A TPN MCCB, 16 KA 4Nos With necessary Aluminium busbars, interconnections, providing , ON,OFF,TRIP, phase indication lamp, Fuse, Switch control etc.in the incomer and also refer the drawing. The incoming and outgoing breakers shall be Microprocessor based release such as overload,short circuit,earth fault,neutral protection,etc. The incomer shall be with Mutlifunctionmetre monitoring V, I, KWH, KVARH, PF with RS 485 BMS integration 800A Amps TP+N Aluminium busbars : All the neutral busbars shall have half the capacity of phase busbars (0.8A/Sq. mm.).

No.

365

SUPPLY, FIXING, TESTING AND COMMISSIONING OF THE SURGE & TRANSIENT PROTECTION AND CONNECTED WORKS WITH ALL NECESSARY FIXING ACCESSORIES ETC COMPLETE AS PER STANDARS AND AS REQUIRED AT SITE SIMILAR TO THE FOLLOWINGS:

Supply of Class B Surge protection device to be installed between L-N and N-PE as per the following specifications: (PROTECTION PROVISION FOR MPCC INCOMER AT INCOMING SIDE) Surge Suppressor system shall consist of Single Spark Gap Class I as per IEC and Class B as per VDE standards, capable of carrying 50 KA,10/350microsec lightning surge between phase to neutral ( 3 Nos for R, Y & B) & 100 KA ,10/350 microsecond neutral to earth (1 no for N-PE) having maximum protection <0.9 KV between phase & neutral and < 1.5 KV between neutral and earth. Surge Protection devices shall be suitable for operation on 415 V, 50 Hz, 3 phase, 4 wire AC supply in TT configuration complying with IEC 61024, IEC 61312 and VDE 0100-534 and tested as per IEC 61643 and VDE 0675 standards.It shall be installed at the input of LT Main panel and the mounting shall be on 35 mm DIN rail

Nos.

OBO Model : 3 nos. Line to Neutral : MCD 50 - B 1no. Neutral to Earth : MCD125-B + NPE Supply of co-ordinated surge protection to be installed between L-N and N-PE as per the following specifications (FOR ALL SUBPANEL INCOMER SIDE) Surge Suppressor system shall consist of Single Spark Gap, Class I as per IEC and Class B as per VDE standards, capable of carrying 50 KA at 10/350 microsec lightning surge between phase to neutral & MOV type category II as per IEC and Class C as per VDE Standards: Pluggable device should be capable of carrying 20 KA,8/20 microsecond surges between phase to neutral and having protection 1.6 KV between phase to neutral and 100 KA at 10/350 microsecond between neutral to earth with a maximum protection of < 1.5 KV between neutral to earth. Surge Protection devices shall be suitable for operation on 415 V, 50 Hz, 3 phase, 4/3 wire AC supply in TT configuration complying with IEC 61024, IEC 61312 and VDE 0100-534 and tested as per IEC 61643 and VDE 0675 standards. OBO Model : V25 B+C/3 +NPE Supply of Class C type Surge Protection Device connection between Phase to Neutral & between Neutral to Earth for Sub distribution system as per the following specifications (FOR ALL UPS RELATED DISTRIBUTION BOARDS)

Nos

55

Nos.

Surge Suppressor MOV type category II as per IEC and Class C as per VDE Standards: Pluggable device should be capable of carrying 20 KA,8/20 microsecond surges between phase to neutral as well as neutral to earth, having protection 1.6 KV between phase to neutral at < 1.0 KV between neutral to Earth including wiring remote indication at all the three phases and visual indication for defects at R, Y, B and Neutral. It shall be installed at the input of Sub Distribution panel and the mounting shall be on 35 mm DIN rail. Surge Protection devices shall be suitable for operation on 415 V, 50 Hz, 3 phase, 4 wire AC supply in TT configuration complying with IEC 61024, IEC 61312 and VDE 0100-534 and tested as per IEC 61643 and VDE 0675 standards OBO Model : V20-C/3+NPE SECTION C : DISTRIBUTION BOARDS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. 366 LPDB / LDB / ELDB :LOC: OFFICE AREA + RECREATIONAL BLOCK + REGIONAL STORE + BACHELOR & TRANSIT + TYPEC&D + Sub station Supply, fixing, testing and commissioning of the double door type compartmental 4way MCCB DB comprising of the following : 32A 4P MCCB 16KA 1 No. as incomer. 25A DP MCB with 25A DP ELCB 30mA 3 Nos. as outgoings. Each 25A DP MCB outgoing consist of 4nos.16/20A 10 KA SPMCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 367 LPDB / LDB :LOC: OFFICE AREA + BACHELOR & TRANSIT

Nos

61

REGIONAL

STORE

Supply, fixing, testing and commissioning of the double door type compartmental 6way MCCB DB comprising of the following : 32A 4P MCCB 16KA 1 No. as incomer. 25A DP MCB with 25A DP ELCB 30mA 3 Nos. as outgoings.

Each 25A DP MCB outgoing consist of 6nos. 6/10/16/20A, 10 KA SP MCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 368 LPDB / LDB :LOC: OFFICE AREA + BACHELOR & TRANSIT Supply, fixing, testing and commissioning of the double door type compartmental 8way MCCB DB comprising of the following : 63A 4P MCCB 16KA 1 No. as incomer. 40A DP MCB with 40A DP ELCB 30mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 8nos. 6/10/16/20A 10 KA SPMCB in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. VTPN DB (AC DB)/ PDB: OFFICE AREA Supply, fixing, testing and commissioning of the double door type VTPN 8way MCCB DB comprising of the following : 100A TPN MCCB 16KA with ELR and all other required accessories 1 No. as incomer. 32A TP MCB 10KA 8 Nos. as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. AC DB / VENTILATION DB (7 segment DB) - 6 WAY LOC: OFFICE + REGIONAL STORE Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 6way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 40A DP MCB 10KA (C-Curve) with 40A DP ELCB 100mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 6nos.16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.

Nos.

Nos

72

369

Nos.

370

With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 371 AC DB / VENTILATION DB (7 segment DB) - 4 WAY LOC: OFFICE + RECREATIONAL BLOCK Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 40A DP MCB 10KA (C-Curve) with 40A DP ELCB 100mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 4nos.16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 372 UPS DB (7 segment DB) - 6 WAY LOC: OFFICE AREA Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 6way MCCB DB comprising of the following : 63A TPN MCCB 1 No. as incomer. 40A DP RCBO Type: Hpi-A with 10KA & 30mA 3 Nos. as outgoings. Each 40A DP RCBO outgoing consist of 6nos.16/20A, 10KA SPMCB (D-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 373 UPS DB (7 segment DB) - 4 WAY LOC: OFFICE + RECREATIONAL BLOCK Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4way MCCB DB comprising of the following : 32A TPN MCCB 1 No. as incomer. 25A DP RCBO Type: Hpi-A with 10KA & 30mA 3 Nos. as outgoings.

Nos.

Nos.

Nos.

Each 25A DP RCBO outgoing consist of 4nos.16/20A, 10KA SPMCB (D-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 374 UPS DB (VTPN DB) - 8 WAY LOC: OFFICE AREA Supply, fixing, testing and commissioning of the double door type VTPN 8way MCCB DB comprising of the following : 100A TPN MCCB 16KA with ELR and all other required accessories 1 No. as incomer. 32A TP MCB 10KA 8 Nos. as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. PDB/LDB (7 segment DB) - 12 WAY LOC: OFFICE AREA + RECREATIONAL BLOCK Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 63A DP MCB 10KA (C-Curve) with 63A DP ELCB 100mA 3 Nos. as outgoings. Each 63A DP MCB outgoing consist of 12nos. 6/10/16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 376 PDB (7 segment DB) - 8 WAY LOC: OFFICE AREA + RECREATIONAL BLOCK Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 40A DP MCB 10KA (C-Curve) with 40A DP ELCB 100mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 8nos. 16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.

Nos.

Nos.

375

Nos.

With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 377 PDB (7 segment DB) - 6 WAY LOC: REGIONAL STORE Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 6way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 40A DP MCB 10KA (C-Curve) with 40A DP ELCB 100mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 6nos.6/10/16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 378 PDB (7 segment DB) - 4 WAY LOC: REGIONAL STORE + TYPE C&D + Sub station Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 4way MCCB DB comprising of the following : 63A TPN MCCB 1No. as incomer. 40A DP MCB 10KA (C-Curve) with 40A DP ELCB 100mA 3 Nos. as outgoings. Each 40A DP MCB outgoing consist of 4nos. 16/20A 10KA SPMCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 379 PDB (VTPN DB) - 12 WAY LOC: OFFICE AREA Supply, fixing, testing and commissioning of the double door type VTPN 12way MCCB DB comprising of the following : 125A TPN MCCB 16KA with ELR and all other required accessories 1 No. as incomer. 32A TP MCB 10KA 12 Nos. as outgoings.

Nos.

No.

No.

With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 380 PDB (VTPN DB) - 4 WAY LOC: REGIONAL STORE Supply, fixing, testing and commissioning of the double door type VTPN 4way MCCB DB comprising of the following : 63A TPN MCCB 16KA with ELR and all other required accessories 1 No. as incomer. 32A TP MCB 10KA 4 Nos. as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. ELDB (SPN DB) - 12 WAY LOC: OFFICE AREA + BACHELOR & TRANSIT + TYPE-C&D Supply, fixing, testing and commissioning of the double door type 12way SPN DB comprising of the following : 32A DP MCB with 32A dp ELCB 30 mA 1 No. as incomer. 6/10A SP MCB 10KA (C-Curve) 6 Nos. as outgoings. With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. 382 EXTERNAL LDB (FEEDER PILLAR BOX) Supply, fixing, testing and commissioning of the double door type VTPN 4 way MCCB DB comprising of the following : 32A 4P MCCB 16KA with 32A 4P Timer & Contactor 1No. as incomer 16A TP MCB 10KA 4Nos. as outgoings. With necessary tinned copper busbars, interconnections, earth bus, neutral bus. The board shall be powder coated type fixed with concealed system in wall. The rate shall include necessary connected civil works like chipping, rough plastering etc. SECTION D : ALUMINIUM CONDUCTOR COMPACT AIR INSULATED BUSDUCT & TAP-OFF BOXES All installation works should be as complete and as directed by Engineer-Incharge.

Nos.

Nos.

381

Nos

37

Nos.

The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. 383 a 200A Aluminium conductor Compact Air insulated Design Rising Main Supply, Installation, Testing and Commissioning of TP+2N, 4Wire, 200A Aluminium conductor Air insulated Design Rising Mains with 15 X 3 (2) External Copper earthing, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 30kA (Busbar Size 20mm X 6mm (1 Runs))Enclosure is 1.6mm GI; Insulation is Class FThe product shall be based on Temp. rise & not on current density 200A End Feed Unit with 25kA TP+2N MCCB End Covers Mounting Brackets (Recommended 1No. per 1.5 Mtrs) 100A Tap Off Box with 16kA TP+2N MCCB 63A Tap Off Box with 16kA TP+2N MCCB 400A Aluminium conductor Compact Air insulated Design Rising Main Supply, Installation, Testing and Commissioning of 4P, 4Wire, 400A Aluminium conductor Air insulated Design Rising Mains with 25 X 3 (2) External Copper earthing, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 30kA (Busbar Size 50mm X 6mm (1 Runs)) Enclosure is 1.6mm GI; Insulation is Class F The product shall be based on Temp. rise & not on current density 400A End Feed Unit with 35kA 4P MCCB End Covers Mounting Brackets (Recommended 1No. per 1.5 Mtrs) 100A Tap Off Box with 16kA 4P MCCB 630A Aluminium conductor Compact Air insulated Design Rising Main Supply, Installation, Testing and Commissioning of 4P, 4Wire, 630A Aluminium conductor Air insulated Design Rising Mains with 25 X 3 (2) External Copper earthing, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 50kA (Busbar Size 90mm X 6mm (1 Runs)) Enclosure is 1.6mm GI; Insulation is Class F The product shall be based on Temp. rise & not on current density 630A End Feed Unit with 50kA 4P MCCB End Covers Mounting Barckets (Recommended 1 per 1.5 Mtrs) 100A Tap Off Box with 16kA 4P MCCB 800A Aluminium conductor Compact Air insulated Design Rising Main RMT 30

b c d e f 384 a

Nos. Nos. Nos Nos. Nos.

2 2 20 1 6

RMT

21

b c d e 385 a

Nos. Nos. Nos Nos.

1 1 14 5

RMT

36

b c d e 386

Nos. Nos. Nos Nos

1 1 24 14

b c d e f g h i

Supply, Installation, Testing and Commissioning of TP+N, 4Wire, 800A Aluminium conductor Air insulated Design Rising Mains with 25 X 3 (2) External Copper earthing, Plug in Point at every 500mm, Fire Barriers at every Floor Crossing : Indoor : 50kA (Busbar Size 50mm X 6mm (2 Runs))Enclosure is 1.6mm GI; Insulation is Class FThe product shall be based on Temp. rise & not on current density 800A End Feed Unit with 50kA 4P MCCB End Covers Mounting Barckets (Recommended 1 per 1.5 Mtrs) 630A Tap Off Box with 35kA 4P MCCB 400A Tap Off Box with 35kA 4P MCCB 200A Tap Off Box with 25kA 4P MCCB 125A Tap Off Box with 25kA 4P MCCB 100A Tap Off Box with 16kA 4P MCCB SECTION E : WIRING AND CONNECTED ACCESSORIES All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

RMT

114

Nos. Nos. Nos Nos. Nos. Nos. Nos Nos.

4 4 76 1 1 1 21 2

387

388

389

Wiring to the Circuit mains (DB to switch board / first point of light fitting) (avg. length - 40 Mtrs)using 2 Runs of 2.5 and 1 Run of 1.5sqmm multi strand PVC insulated copper conductor (FRLS) in 25mm dia. MS pipe in open system in above false ceiling and concealed system in below false ceiling, all complete complying with relevant standard specifications Wiring to the Circuit mains (DB to switch board / first point) (avg. length - 40 Mtrs)using 2 Runs of 2.5 and 1 Run of 1.5sqmm multi strand PVC insulated copper conductor (FRLS) in existing MS pipe in open system in above false ceiling and concealed system in below false ceiling, all complete complying with relevant standard specifications Wiring to the light points/ 6A plug point using 2 Runs of 2.5 and 1 Run of 1.5sqmm for primary point (switch to first point) and 3 Runs of 1.5 Sqmm for secondary point) (looping), multi strand PVC insulated copper conductor (FRLS) in suitable size MS pipe in open system in above false ceiling and concealed system in below false ceiling. The primary point rate should inclusive of supply and fixing of 6A modular type switch in a suitable size modular box in concealed system,the secondary point rate should inclusive of supply, laying of GI flexible hose for lighting drops from ceiling, all complete complying with relevant standard specifications Primary point Secondary point

Pts.

110

Pts.

90

a b

Pts. Pts.

650 850

390

Wiring to the lift well light and power points using 2 Runs of 2.5 sqmm and 1 Run of 1.5 sqmm multi strand PVC insulated copper conductor (FRLS),separate circuit (from DB) shall be laid for power points in suitable size MS pipe in open system.The rate should inclusive of supply and fixing of 1 No. of 6A switch for control the light and 1 No. 6A socket controlled by 6A modular type switch in a suitable size modular box with face plate and all other necessary accessories. Wiring to the 6/16A 5Pin or 6Amps Raw power / UPS socket using 3C X 2.5 sqmm copper flexible cable (FRLS) in existing raceway / conduits (under floor) with all other necessary accessories. Wiring to the 6/16A 5Pin or 6Amps Raw power / UPS socket and also wiring to IBMS systems using 2 Runs of 2.5 sqmm and 1Run of 1.5 sqmm multi strand PVC insulated copper conductor (FRLS) in 25mm dia. MS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column etc. Wiring to the 6/16A 5Pin or 6Amps Raw power / UPS socket using 2 Runs of 2.5 sqmm and 1Run of 1.5 sqmm multi strand PVC insulated copper conductor (FRLS) in existing MS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column etc. Wiring to the 6/16A 5Pin Raw power / UPS socket using 3C X 4 sqmm copper flexible cable (FRLS) in existing raceway / conduits (under floor) with all other necessary accessories. Wiring to the power plugs using 2 Runs of 4 sq.mm and 1 Run of 2.5 sqmm multi strand PVC insulated copper conductor (FRLS) in a suitable size MS pipe in open system at above false ceiling and concealed system in below false ceiling in wall / column etc. (For Air conditioner) LOC : Type C&D + Regional store Wiring to the Circuit mains (DB to switch board / first point of light fitting) (avg. length - 18Mtrs)using 2 Runs of 2.5 and 1 Run of 1.5sqmm multi strand PVC insulated copper conductor (FRLS) in suitable size PVC HMS pipe in open system in above false ceiling and concealed system in below false ceiling, all complete complying with relevant standard specifications

Pts.

78

391

RMT

4800

392

RMT

4700

393

RMT

300

394

RMT

2900

395

RMT

2100

396

Pts.

500

397

Wiring to the light/fan points, primary & secondary point (switch to first point and looping) using 3 Runs of 1.5 Sqmm multi strand PVC insulated copper conductor (FRLS) in suitable size PVC HMS pipe in open system in above false ceiling and concealed system in below false ceiling. The primary point rate should inclusive of supply and fixing of 6A modular type switch in a suitable size modular box in concealed system, all complete complying with relevant standard specifications Primary point Secondary point Wiring to the 6/16A 5 pin or 6 amps Raw power / UPS socket using 2 Runs of 2.5 sqmm and 1Run of 1.5 sqmm multi strand PVC insulated copper conductor (FRLS) in 25mm dia. PVC HMS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column etc. Wiring to the 6/16A 5 pin or 6 amps Raw power / UPS socket using 2 Runs of 2.5 sqmm and 1Run of 1.5 sqmm multi strand PVC insulated copper conductor (FRLS) in existing PVC HMS pipe in open system above false ceiling and concealed system in below false ceiling in wall / column etc. Wiring to the power plugs using 2 Runs of 4 sq.mm and 1 Run of 2.5 sqmm multi strand PVC insulated copper conductor (FRLS) in a suitable size PVC HMS pipe in open system at above false ceiling and concealed system in below false ceiling in wall / column etc. (For Air conditioner) Supply, fixing, testing and commissioning of 2Nos. 6/10 / 13A modular type Universal socket for UPS Power supply and switch combination in a suitable size modular box in recessed system. (2Nos.6/10/13A modular socket controlled by 2Nos.16A Switches) Supply, fixing, testing and commissioning of 1No. 6/16A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.6/16A modular socket controlled by 1No.16A Switch) Supply, fixing, testing and commissioning of 1No. 6/16A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.6/16A modular socket controlled by 1No.16A Switch). Similar to Legrand Myrius Supply, fixing, testing and commissioning of 1No. 6/16A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.6/16A modular socket controlled by 1No.16A Switch). Similar to Legrand Arteor Pts. Pts. RMT 3195 1232 9500

a b 398

399

RMT

4700

400

RMT

11000

401

Nos.

176

402

Nos.

460

403

Nos

275

404

Nos

10

405

406

407

408

409

Supply, fixing, testing and commissioning of 1No. 16A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.16A modular socket controlled by 1No.16A Switch) Supply, fixing, testing and commissioning of 1No.6A modular socket for Raw Power supply and switch combination in a suitable size modular box in recessed system.(1No.6A modular socket controlled by 1No.6A switch) Supply, fixing, testing and commissioning of 1No. 6A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.6A modular socket controlled by 1No.6A Switch). Similar to Legrand Myrius Supply, fixing, testing and commissioning of 1No. 6A modular type socket for Raw Power supply and switch combination in a suitable size modular box in recessed system. (1No.6A modular socket controlled by 1No.6A Switch). Similar to Legrand Arteor Supply, fixing, testing and commissioning of 1No.6A modular socket for Raw Power supply in a suitable size modular box in recessed system.(1No.6A modular type socket ) (For exhaust fan point) Similar to Legrand Myrius Supply, fixing, testing and commissioning of 1No.16A modular socket for Raw Power supply in a suitable size modular box in recessed system.(1No.16A modular type socket ) (For Gyser ) Similar to Legrand Myrius Design, supply,fixing, testing and commissioning of 20A 3 pin metal clad socket controlled by 20A DP MCB in a suitable size MS enclosure fixed in open system. (For Air conditioner) Design, supply,fixing, testing and commissioning of 32A 5 pin metal clad socket controlled by 32A 4P MCB in a suitable size MS enclosure fixed in open system. Design, supply, fixing, testing and commissioning of 20A, 5 pin metal clad socket controlled by 20A 4P MCB in a suitable size MS enclosure fixed in open system. ( For AC system) Design, supply,fixing, testing and commissioning of 16A, 3 pin polycorbonite socket controlled by 16A DP MCB in a suitable size weatherproof enclosure fixed in open system. Design, supply, fixing, testing and commissioning of 32A 4P MCB in a suitable size weatherproof enclosure fixed in open system. Design, supply, fixing, testing and commissioning of 63A TPN MCCB in a suitable size weatherproof enclosure fixed in open system. Design, supply, fixing, testing and commissioning of 125A TPN MCCB in a suitable size weatherproof enclosure fixed in open system.

Nos.

55

Nos.

404

Nos

1912

Nos

82

Nos.

250

410

Nos.

177

411

Nos.

478

412

Nos.

22

413

Nos.

414

Nos.

20

415

Nos.

22

416

Nos.

417

Nos.

418

419

420

421

422

423

424

425

426 427

428

429

430

431

432

433

434

Design, supply, fixing, testing and commissioning of 63A TPN MCCB in a suitable size MS enclosure fixed in open system. Design, supply, fixing, testing and commissioning of 125A TPN MCCB in a suitable size MS enclosure fixed in open system. Supply and fixing of suitable size metal box to fix the RJ45 Data socket. The rate shall include the wall cutting, chipping and rough finishing etc., Supply, fixing, testing and commissioning of RJ45 Data socket with suitable modular plate and metal box.. Similar to Legrand Myrius Supply, fixing, testing and commissioning of RJ45 Data socket with suitable modular plate and metal box.. Similar to Legrand Arteor Supply and fixing of suitable size metal box to fix the RJ11 Telephone socket. The rate shall include the wall cutting, chipping and rough finishing etc., Supply, fixing, testing and commissioning of RJ11 Telephone socket with suitable modular plate and metal box. Similar to Legrand Myrius Supply, fixing, testing and commissioning of RJ11 Telephone socket with suitable modular plate and metal box. Similar to Legrand Arteor Supply, fixing, testing and commissioning of TV socket with suitable modular plate and metal box. Supply, fixing, testing and commissioning of TV socket with suitable modular plate and metal box. Similar to Legrand Myrius Supply, fixing, testing and commissioning of TV socket with suitable modular plate and metal box. Similar to Legrand Arteor supply, fixing, testing and commissioning of 1 No. of 6A 1 way modular switch in a suitable size face plate with metal box and all other necessary accessories. supply, fixing, testing and commissioning of 1 No. of 6A 2way modular switch in a suitable size face plate with metal box and all other necessary accessories. Similar to Legrand Myrius supply, fixing, testing and commissioning of 1 No. of 6A 2way modular switch in a suitable size face plate with metal box and all other necessary accessories. Similar to Legrand Arteor supply, fixing, testing and commissioning of 1 No. of 16A modular switch in a suitable size face plate with metal box and all other necessary accessories. Similar to Legrand Myrius supply, fixing, testing and commissioning of 1 No. of electronic regulator in a suitable size face plate with metal box and all other necessary accessories. Similar to Legrand Myrius supply, fixing, testing and commissioning of 1 No. of electronic regulator in a suitable size face plate with metal box and all other necessary accessories. Similar to Legrand Arteor

Nos.

Nos.

Nos.

10

Nos.

Nos.

Nos.

10

Nos

406

Nos

18

Nos. Nos

75 169

Nos.

Nos.

10

Nos.

564

Nos.

35

Nos.

190

Nos

546

Nos

26

435

436

437 438

a b c d e f g h 439

Supply, fixing, testing and commissioning of Calling bell/ Buzzer with push type switch and Buzzer / Bell. Similar to Legrand Myrius Supply, fixing, testing and commissioning of Calling bell/ Buzzer with push type switch and Buzzer / Bell. Similar to Legrand Arteor Supply and fixing of fan hook with all other necessary accessories. Supply and laying of following size PVC / MS conduits in floor / wall /ceiling etc. including necessary bends,elbow,etc, in concealed system below the false ceiling on wall/floor and open system on above false ceiling. FOR ELECTRICAL, DG, IBMS , DATA & TELEPHONE SYSTEMS) The rate shall includes minor civil works such as chipping, plastering and to make good finished surface to match with the original surface. 20mm dia MS conduit. 25mm dia MS Conduit 32mm dia MS Conduit 50mm dia MS Conduit 20mm dia PVC HMS Conduit 25mm dia PVC HMS Conduit 32mm dia PVC HMS Conduit 50mm dia PVC HMS Conduit Supply and installation of under floor pregalvanised sheet steel channel (raceways) as per the detailed specification as below: Supply, fixing of the 100 x 38 X 1.6mm pregalvanised sheet steel Channel (Raceways) including stiffner at required intervals in recessed system in floor including cutting chippling, plastering in the floor/wall to make good finish to match with the floor /wall etc. (Similar to MK list No. - UMDX 100/1/6) Joint Sleeve for UMDX 100/1/6 Supply, fixing of the 150 x 38 X 1.6mm pregalvanised sheet steel Channel (Raceways) including stiffner at required intervals in recessed system in floor including cutting chippling, plastering in the floor/wall to make good finish to match with the floor /wall etc. (Similar to MK list no. - UMDX 150/2/6) Joint Sleeve for UMDX 150/1/6 Supply, fixing of the 300 x 38 X 1.6mm pregalvanised sheet steel Channel (Raceways) including stiffner at required intervals in recessed system in floor including cutting chippling, plastering in the floor/wall to make good finish to match with the floor /wall etc. (Similar to MK list no. - UMDX 300/3/6) Joint Sleeve for UMDX 300/1/6

Nos

105

Nos.

Nos

572

RMT RMT RMT RMT RMT RMT RMT RMT

100 3800 50 50 100 100 700 100

RMT

340

b c

Nos RMT

136 120

d e

Nos RMT

48 200

Nos

80

Supply, fixing of the 50 x 25 X 1.6mm pregalvanised sheet steel Channel (Raceways) including stiffner at required intervals in recessed system in floor including cutting chippling, plastering in the floor/wall to make good finish to match with the floor /wall etc. (Similar to MK list no. - UMDX 50/1/6) Joint Sleeve for UMDX 50/1/6 Supply, fixing of the 100 x 25 X 1.6mm pregalvanised sheet steel Channel (Raceways) including stiffner at required intervals in recessed system in floor including cutting chippling, plastering in the floor/wall to make good finish to match with the floor /wall etc. (Similar to MK list no. - UMDX 100/1/6) Joint Sleeve for UMDX 100/1/6 Supply, fixing, testing of under floor access outlet box / Floor junction box / crossover junction box as per the detailed specification as below: The rate shall includes cutting the existing floor with use of cutting machine and chipping the cement mortar and the debris shall be removed from the site. After fixing the trunking the floor shall be plastered to match the original surface. Floor access outlet boxes Supply of MK access outlet boxes, manufactured from high-pressure die cast material with trap frame & trap made of flame retardant Engineering Plastic . ABS. Patented screwless polyamide ratchets are provided for self adjusting of the floor box for any floor finishes. Trap cover is reinforced with a 2.5mm thick pre-galvanized steel plate with a recess of 8mm for accommodating the flooring.The trap cover is provided with Electrostatic Polyester Epoxy Coating, to prevent rust accumulation. The system has provision to accommodate three compartment trunking to run Mains Voltage & Extra Low Voltage cables. The system has Positive Double Earthing Connections to ensure safety.The system also has the provision to accommodate 25/38mm deep trunking with a Knockout of 65,100,150,200,225mm. Load bearing Capacity: 2 tons; Dimensions: 250*250mm similar to MK List No.ESB 250/3/1 in the Existing floor with concealed system. Combination of switch & sockets will be decided at the time of execution

RMT

75

h i

Nos RMT

30 25

j 440

Nos

10

Nos.

441

Floor Junction Boxes without flyover Supply and fixing of Junction boxes manufactured from high-pressure die cast material. The Trap Cover & Trap frame of the box should be made of 2.5mm thick pregalvanized steel plate made of Electrostatic Polyester epoxy coating. The recess should be 8mm on the trap lid to accommodate the specified flooring.

The junction boxes should have the provision to route and distribute either the power or networking cables. The system must have smooth curved die cast pillars for ease of pulling cables. The system must have the provision to accommodate 25/38mm deep and upto 225mm wide GI trunking. similar to MK List No.JB 150 / 250 / 300 / 350 / 400 Height adjustment: The system must have the stainless steel leveling screws; Load bearing Capacity: 3.6 tons on the trap lid; Standards: The system must comply with the relevant specification & IEC 61084 a b c d e 442 JB 150 JB 250 JB 300 JB 350 JB 400 Cross Over Junction Boxes without flyover Supply and fixing of Junction boxes manufactured from high-pressure die cast material. The Trap Cover & Trap frame of the box should be made of 2.5mm thick pregalvanized steel plate made of Electrostatic Polyester epoxy coating. The recess should be 8mm on the trap lid to accommodate the specified flooring. The cross over boxes should have flyover units made of ABS plastic or metal to route and distribute power, data and voice cables. The system must have smooth curved die cast pillars for ease of pulling cables. The system must have the provision to accommodate 25/38mm deep and upto 225mm wide GI trunking. similar to MK List No.EJB 250 / 300 / 350 / 400 Height adjustment: The system must have the stainless steel leveling screws; Load bearing Capacity: 3.6 to 4.8 tons on the trap lid; Standards: The system must comply with the relevant specification & IEC 61084 EJB 250 EJB 300 EJB 350 EJB 400 Telephone and lan cabling Supplying, fixing, connecting and commissioning of reputed Brand 10Pair Krone Connector Type Telephone Tag Block in 16G Thick sheet steel enclosure at each flat fixed flush with the wall. Supplying, fixing, connecting and commissioning 20 Pair KRONE CONNECTOR TYPE Telephone Tag Block - Sub Tag Block in 14 G Thick sheet steel enclosure at Each Floor. Supplying,fixing,connecting and commissioning 200 Pair KRONE CONNECTOR TYPE Telephone Tag Block Main Tag Block in 14 G Thick sheet steel enclosure at Ground Floor Nos Nos Nos Nos Nos 60 25 25 40 20

a b c d 443 a

Nos. Nos. Nos. Nos. Nos.

5 2 5 1 32

Nos.

32

Nos.

Supplying, laying, connecting & commissioning of reputed brand 3 Pair un armoured with colour coded 0.5 Sq.mm. annealed copper conductor Telephone cable in already laid PVC Conduits/ raceways concealed in floor / Ceiling /wall with necessary clamps,screws etc from 5 pair Krone Connector to each telephone points. Supplying, laying, connecting & commissioning of reputed brand 10Pair un armoured with colour coded 0.5 Sq.mm. annealed copper conductor Telephone cable in already laid PVC Conduits / raceways concealed in floor / Ceiling / wall with necessary clamps, screws etc. Supplying, laying and concealing of PVC pipe of 25mm dia with necessary specials and other materials including Run off 1 No. Fish wire (G.I. 22g) for drawing cable for Telephone / data etc., all complete and as per specifications Supplying, laying, connecting & commissioning 20 pair un armoured with colour coded 0.5 Sq.mm annealed copper conductor Telephone cable in already laid PVC Conduits concealed in floor / Ceiling /wall with necessary clamps, screws etc from Man Tag block at Ground floor to Sub Tag block at each floor TV CABLING Supplying, connecting and commissioning of reputed brand RG 6 Trunk Co-axial cable in already laid PVC Conduits concealed in wall / ceiling / floors with necessary clamps, screws etc. Supplying, fixing, connecting and commissioning of 6Way Splitter at Each Flat Supplying, laying and concealing of PVC pipe of 25mm dia with necessary specials and other materials including Run off 1 No. Fish wire (G.I. 22g) for drawing cable for T.V. etc., all complete and as per specifications SECTION F : POWER AND CONTROL CABLES / TERMINATIONS: All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

RMT

5500

RMT

1500

RMT

2500

RMT

1500

444 a

RMT

7000

b c

Nos. RMT

40 2500

445

Supply, laying of following size XLPE / PVC (FRLS) insulated armoured cables with aluminium / copper conductors partly laid in existing cable tray and partly laid in wall/ ceiling with suitbale clamps for working voltages up to and including 1100V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE. Cable tray will be measured and paid separately. FOR ELECTRICAL, DG, IBMS , FPS & HVAC SYSTEMS) 3.5 Core 400 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 240 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 150 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 120 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 50 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable 4 Core 25 Sq.mm XLPE Aluminium armoured Cable 4 Core 16 Sq.mm XLPE Aluminium armoured Cable 4 Core 6 Sq.mm PVC Copper armoured Cable (FRLS) 3 Core 4 Sq.mm PVC Copper armoured Cable (FRLS) 3 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 1 Core 150 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 70 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 35 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 25 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 16 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 10 Sq.mm PVC Copper Unarmoured Cable (FRLS) 24 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 12 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 7 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 4 Core 4 Sq.mm PVC Copper armoured Cable (FRLS) Supply and termination of the following size cables with suitable double compression glands with suitable crimping socket. (copper sockets for copper cables and Alu. Sockets for alum. Cable) FOR ELECTRICAL, DG, IBMS , FPS & HVAC SYSTEMS) 3.5 Core 400 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT 2830 400 900 55 32 2700 750 2900 3800 3200 95 7900 440 650 900 230 20 330 100 100 50 2500

a b c e f i j k l n o p s t u v w x z aa ab ac 446

a b

Nos. Nos.

36 4

c d e f g h i j k l m n o p q r s t u v w

3.5 Core 240 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 150 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 120 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 50 Sq.mm XLPE Aluminium armoured Cable 3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable 4 Core 25 Sq.mm XLPE Aluminium armoured Cable 4 Core 16 Sq.mm PVC Aluminium armoured Cable (FRLS) 4 Core 6 Sq.mm PVC Copper armoured Cable (FRLS) 3 Core 4 Sq.mm PVC Copper armoured Cable (FRLS) 3 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 1 Core 150 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 70 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 35 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 25 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 16 Sq.mm PVC Copper Unarmoured Cable (FRLS) 1 Core 10 Sq.mm PVC Copper Unarmoured Cable (FRLS) 24 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 12 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 7 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) 4 Core 4 Sq.mm PVC Copper armoured Cable (FRLS) 4 Core 2.5 Sq.mm PVC Copper armoured Cable (FRLS) SECTION G : Earthing system ( FOR ELECTRICAL, DG, IBMS , FPS & HVAC SYSTEMS) All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos.

26 4 4 58 56 222 244 66 2 132 80 20 44 16 4 32 4 4 4 80 27

447

448

449 450 451 452 453 454

Supply and installation of earth pipe electrode as per IS 3043 complete with 3mtr long with 40mm dia 'B' class G.I. pipe and GI earth plate of size 600mm x 600mm x 6mm including 2 runs of 50 x 6mm GI flat upto test link from plate earth electrode, watering funnel and necessary bolt, nut and double washer. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame and lockable facility. The plate electrode shall be filled with alternate layer of salt and charcoal as required full depth. The Cover shall be heavy duty to suit heavy vehicle movements Supply and installation of earth pipe electrode as per IS 3043 complete with 3 mtr long with 40mm dia 'B' class G.I. pipe and copper earth plate of size 600mm x 600mm x 3mm including 2 runs of 25 x 6mm CU. flat upto test link from plate earth electrode, watering funnel and necessary bolt, nut and double washer. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame and lockable facility. The plate electrode shall be filled with alternate layer of salt and charcoal as required full depth. The Cover shall be heavy duty to suit heavy vehicle movements Supply and laying of 50 x 6 mm G.I flat Supply and laying of 25 x 6 mm G.I flat Supply and laying of 25 x 3 mm Cu flat Supply and laying of 8 gauge bare copper wire Supply and laying of 50 x 10 mm copper flat for Neutral Supply, erection of following sizes GI ladder / perforated type cable rack system made out of sheet steel folded to required shape with adequate number of supports. ( FOR ELECTRICAL, DG, IBMS , FPS & HVAC SYSTEMS) The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc. complete with all civil works for fabrication details. Refer enclosed drawing.

Nos

24

Nos

36

RMT RMT RMT RMT RMT

370 350 340 2580 150

The rate shall be inclusive of suitable hanging support gripple make cable with crimp arrangement supports, spacing and fixing as per standards. The height of the hanging arrangement shall be as per drawing and with all accesories to fix the hangers at purlin, rafter beam with required clamps nuts & bolts to be considered. Perforated type 300mm x 75mm x 2.0mm 450mm x 75mm x 2.0mm Ladder type 450mm x 75mm x 2.0mm 600mm x 75mm x 2.0mm 750mm x 75mm x 2.0mm 1000mm x 75mm x 2.5mm Sheet steel of 14G for connecting the tray. 25 x 6 mm copper Earth busbar - 1 mtr long with necessary insulator supports SECTION H : SAFETY EQUIPMENTS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. 457 Supply and laying of class B, 2.5mm thickness 1M X 2M wide chequered rubber mat with dielectric strength of 45KV suitable for 11KV installation as per IS 15625 / 2006 Supply and laying of class 2, 3mm thickness 1M X 2M wide chequered rubber mat suitable for 440V installation as per IEC 61111 Supply and fixing of HT/LT cable route indicator made out of MS flat and angle iron. The cable route marker shall be fixed at both the ends of cable at joints at 50Mtrs. Spacing for straight runs. Supply and providing shock treatment chart in English, Hindi and Tamil duly framed with 2mm thick glass in front & 6mm thick ply on back as required Supply and fixing of GI fire buckets with round bottom, each set comprising 4Nos.fire buckets of 9Kg capacity including supply of M.S pedestal stand with hooks suitable for holding of 4Nos of fire buckets, painted with Post Office Red oil paint and letter FIRE on each bucket and filling with sand complete as required. . Supply of tested hand gloves of 11KV grade. Supply and providing St. John make first aid box 18SWG MS sheet duly painted as approved by Indian red cross soceity complete with all first aid medicines. Nos. 3

a b c d e f 455 456

RMT RMT RMT RMT RMT RMT Sqm. Nos

400 350 900 50 800 60 70 10

458

Nos

25

459

Nos

200

460

Nos

10

461

Nos

10

462 463

Nos. Nos.

2 6

464

Supply & Fixing HT danger notice plate 250mm x 200mm made of MS steel 2mm thick & Vitreous enameled white on both sides and with inscriptions in signal Red on front side as required by the electrical authorities. Supply & Fixing LT danger notice plate 200mm x 150mm made of MS steel 2mm thick & Vitreous enameled white on both sides and with inscriptions in signal Red on front side as required Supply & Fixing of Artificial Respirator for Inspiration with chart showing the use of it. Supply & Fixing of MS sheet board of size 500mm x 300mm of 16 SWG with Entry Restricted To Authorised Persons Only near the Main entrance of the Substation. The lettering shall be Black painted on Yellow Back ground. SECTION I: EXTERNAL WORKS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

Nos.

465

Nos.

466 467

Nos Nos

10 10

468 469 470 471

Supply & laying of 40 mm dia. GI pipe for cable entry in the pole foundation Design, supply & laying of the 8 SWG bare copper wire for earthing. Supply and Installation of 20mm dia., 1.5mtr long GI earthing spike for street light pole earthing Similar to SCHREDER-Teceo 1 Glass Extra Clear Flat Smooth 27W LED Teceo 1 luminaire made up of Die cast aluminium alloy body should be of IP66 Tightness level for both the optical compartment and the control gear compartment.The LED chip should be arranged on a stainless steel plate and should be sealed with a extra clear toughned glass for a optimal luminous flux and ensuring a tightness level of IP66 for the optical compartment. LensoFlex2 :Photometric engine specifically dedicated to offering photometric flexibility and performance.Leds in Neutral white (4100K) should be equpped with Special developed lenses for proper road lighting photometry. Future Proof: The optical unit should be easily removed and replaced at the real site at the end of the service life in order to take the advantage of the future technological developments. THermix :Large surface area for better heat management.

RMT RMT Nos

170 350 92

The LED engine should contain 16 nos of LED with 1.2 W each LED.The luminaire should be protected agaisnt surge up to 10 KV.The optical compartmnet and the electronic compartment should be separate compartments for heat management.The electrical connections should be automatically cutoff while opening the control gear compartment.The luminaire should be provided with universal mounting clamp which also allows the luminaire to change the inclination as required at site.All the wires used inside the luminaire should be of silicon wires and all the screws used should be of stainless steel. The LED engine should contain 16 nos of LED driven at a current of 500mA to give an total wattage of around 41W. System luminous flux < 4176 lumens; Burning life : 90% output at 60,000 burning hrs and 70% output at 1L burning hrs; Colour tempearture: 4100K; CRI > 65; LED :Rebel-ES NW 174lm@500mA Similar to KESELEC SCHREDER CONICAL POLE GI OF6 MTR HT. The column should be made up of hot dipped galvanized iron which should be bended and tapered towards the top. The total height of the pole should be 6200 mm and the lighting luminaire should be mounted at a height of 6000 mm.The column should be given with two coats of epoxy primer and above that it should be given with polyeruthane UV resistantt coating.The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening. A junction/ looping box with Heavy duty 3 phase connector shall be built into the pole. COLOR - As per standard shade card. 473 Similar to Keselec Schreder Neos3/IB/250W/1312 /IP66 The floddlight luminaire with a tightness level of IP66 suitable for 250W Metal halide .The body should consist of two parts made of painted,die cast aluminium alloy.The body contains a reflector made of polioshed and anodized aluminium and a removable control gear plate .The protector is made of hardened glass .It is sealed to the cover with a silicone gasket.The luminaire should be having a powder coating finish.The Impact resistance of the glass should be IK08 Electrical insulation class should be I or II in accordance with standard EN 60598.All the cables used inside the luminaire should be silicon cables which is fire resisitant.The empty weight of the fixture should be around 8 Kg.A mounting bracket has to be provided inorder to adjust the flood light luminaire as per the required angle.Lamp Color:830 Nos 30 Nos 92 Nos 92

472

Lamps: 1 x 250W MHL

474

Similar to Keselec Schreder Corus/IB/70W/1602/CDMT .Lamp Color Code:830 Corus Consisting of painted die-cast aluminium alloy body and hardened glass protector sealed onto the body by means of a silicone gasket.The floodlight is closed at one end by a painted,die cast aluminium alloy cover,and at the other end,by a frame and door assembly also made of painted,die cast aluminium alloy.The reflector made of polished and anodised aluminium and the control gear are removable. Suitable for 70W CDMT Lamp. Lamps: 1 x 70W CDMT Similar to KESELEC SCHREDER ZIA TILTABLE/24 DEG/1216MM/70WLED /IP67/Blue Nos 10

475

LED Nos 42

476

Illumination in continuous lines Continuous lines with an easy & invisible in-out system Various installation possibilities: fixed or adjustable on-site Linear floodlight 400mm lengths . Numerous symmetrical light distributions Monochromatic or RGB versions Static or dynamic versions Sturdy mechanical conception: aluminium, fiber-glass reinforced polyester & glass IP 67 tightness level Optimized thermal dissipation Lamps: 70W LED Similar to Keselec Schreder Corus/IB/70W/1639M/CDMT .Lamp Color Code:830 Corus Consisting of painted die-cast aluminium alloy body and hardened glass protector sealed onto the body by means of a silicone gasket.The floodlight is closed at one end by a painted,die cast aluminium alloy cover,and at the other end,by a frame and door assembly also made of painted,die cast aluminium alloy.The reflector made of polished and anodised aluminium and the control gear are removable. Suitable for 70W CDMT Lamp. Color Pure White Lamps: 1 x 70W CDMT Similar to Keselec Schreder FOCAL/CMHB/150W/1576/IP66/830 FOCAL Floodlight (IP66)consisting of a painted ,die cast aluminium alloy body and cover.The body contains the control gear plate and the lamp holder support with a fine adjustment screws for the fine adjustment of the focusing of the lamp when switched on.The optical compartment consists of hardened glass sealed onto the body and a reflector made of deep drawn,polished and anodised aluminium.suiable for 150W CDMT lamp.All the cables used inside the luminaire should be silicon cables which is fire resisitant.It should be provided with a mounting clamp which enables the mounting of the luminaire at 3 mtr ht on th facade of the building.

Nos

477

Nos.

Lamps: 1 x 150W CDMT RECREATIONAL BLOCK

478

Similar to Keselec Schreder Corus/IB/35W/1639M/CDMT .Lamp Color Code:830 Corus Consisting of painted die-cast aluminium alloy body and hardened glass protector sealed onto the body by means of a silicone gasket.The floodlight is closed at one end by a painted,die cast aluminium alloy cover,and at the other end,by a frame and door assembly also made of painted,die cast aluminium alloy.The reflector made of polished and anodised aluminium and the control gear are removable. Suitable for 35W CDMT Lamp. Color Pure White Lamps: 1 x 35W CDMT Similar to Keselec Schreder Enyo 3 LED Static Version Warm white Schreder Enyo:Hyper-compact spotlight Numerous symmetrical light distributions It should be of Static (mono) with 3 High power LEDs of 1.2W Sturdy mechanical conception: aluminium, stainless steel & glass shule be made up of aluminim,Glass and Stainless steel IP 67 tightness level Optimized thermal dissipation Nos 10

479

Nos

32

480

Similar to Keselec Schreder Corus/IB/35W/1639M/CDMT .Lamp Color Code:942 Corus Consisting of painted die-cast aluminium alloy body and hardened glass protector sealed onto the body by means of a silicone gasket.The floodlight is closed at one end by a painted,die cast aluminium alloy cover,and at the other end,by a frame and door assembly also made of painted,die cast aluminium alloy.The reflector made of polished and anodised aluminium and the control gear are removable. Suitable for 35W CDMT Lamp. Color Pure White Lamps: 1 x 35W CDMT Similar to Keselec Schreder FOCAL/CMHB/150W/1576/IP66/942 FOCAL Floodlight (IP66)consisting of a painted ,die cast aluminium alloy body and cover.The body contains the control gear plate and the lamp holder support with a fine adjustment screws for the fine adjustment of the focusing of the lamp when switched on.The optical compartment consists of hardened glass sealed onto the body and a reflector made of deep drawn,polished and anodised aluminium.suiable for 150W CDMT lamp.All the cables used inside the luminaire should be silicon cables which is fire resisitant.It should be provided with a mounting clamp which enables the mounting of the luminaire at 3 mtr ht on th facade of the building. Nos 10

481

Nos.

482

Lamps: 1 x 150W CDMT Similar to Keselec Schreder Terra Maxi/IB/150W/1453M with Kit Lamo Color Code:830

483

Embedded flood light (IP 67) - a pressure die cast aluminium alloy body and cover cover attached to the body with 4 nos. stainless steel rapid closing mechanisms; toughened 19mm thick glass protector capable of withstanding load of 3 tons; a double gasket recessed into the body, removable control gear tray, pre-wired with 2.5 sq mm, 3 core copper flexible cable 1.5m long with spun and anodised aluminium reflector and suitable for 150W CDMT lamps Lamps: 150W CDMT Similar to Keselec Schreder Corus/IB/70W/1602/CDMT .Lamp Color Code:942 Corus Consisting of painted die-cast aluminium alloy body and hardened glass protector sealed onto the body by means of a silicone gasket.The floodlight is closed at one end by a painted,die cast aluminium alloy cover,and at the other end,by a frame and door assembly also made of painted,die cast aluminium alloy.The reflector made of polished and anodised aluminium and the control gear are removable. Suitable for 35W CDMT Lamp. Color Pure White Lamps: 1 x 35W CDMT SECTION J : UPS SYSTEM & CONNECTED WORKS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Supply, fixing, Testing and commissioning of the following UPS System and connected works with all necessary accessories complete as required at site and as per standards.

Nos.

Nos

484

Supply, Installation Testing and Commissioning of Micro Processor Controlled 1 x 70 KVA UPS input supply of 415 Volts + 15%, 3 Phase, 50 Hz 10% and an out put of 415 Volts 1%, 3 Phase 50 0.1 Hz, Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <2.5%, Unity Output Power Factor @ 35deg C consisting of Rectifier, Inverter, External Isolation Transformer, Battery DC Circuit Breaker with necessary MS enclosure, Inbuilt Static BY PASS Panel (Input & output switches and Auto Static & Manual Bypass Switches), necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS, complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. Supply, Installation, Testing and Commissioning of Sealed Maintenance Free Batteries to support 70KVA for 20 minutes complete with intercell connectors & copper cables, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries. Supply, Installation Testing and Commissioning of Micro Processor Controlled 1 x 60 KVA UPS input supply of 415 Volts + 15%, 3 Phase, 50 Hz 10% and an out put of 415 Volts 1%, 3 Phase 50 0.1 Hz, Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <2.5%, Unity Output Power Factor @ 35deg C consisting of Rectifier, Inverter, External Isolation Transformer, Battery DC Circuit Breaker with necessary MS enclosure, Inbuilt Static BY PASS Panel (Input & output switches and Auto Static & Manual Bypass Switches), necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS, complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. Supply, Installation, Testing and Commissioning of Sealed Maintenance Free Batteries to support 60KVA for 20 minutes complete with intercell connectors & copper cables, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries.

No.

485

No.

486

No.

487

No.

488

Supply, Installation, Testing and commissioning of Micro Processor Controlled 1 x 20KVA standalone UPS ( Application: For Emergency Lighting, BMS, VAV & Security service loads) input supply of 415 Volts +/- 15%, 3 Phase, 50 Hz 10%, an out put of 415 Volts 1%, 3 Phase 50 0.1 Hz , Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <2.5%, Unity Output Power Factor @ 35deg C consisting of Rectifier, Inverter, Battery DC Circuit Breaker with necessary MS enclosure, Inbuilt Static BYPASS( Input & output switches and Auto Static & Manual Bypass Switches), necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. Supply, Installation, Testing and commissioning of Micro Processor Controlled 1 x 10KVA standalone UPS ( Application: For Emergency Lighting, BMS, VAV & Security service loads) input supply of 415 Volts +/- 15%, 3 Phase, 50 Hz 10%, an out put of 415 Volts 1%, 3 Phase 50 0.1 Hz , Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <2.5%, Unity Output Power Factor @ 35deg C consisting of Rectifier, Inverter, Battery DC Circuit Breaker with necessary MS enclosure, Inbuilt Static BYPASS( Input & output switches and Auto Static & Manual Bypass Switches), necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. Supply, Installation, Testing and Commissioning of Sealed Maintenance Free Batteries to support 10KVA for 20 minutes complete with intercell connectors & copper cables, battery stand made out of Powder Coated MS Angles with adequate supports to carry the load of the batteries.

No.

489

No.

490

No.

491

Supply, Installation, Testing and commissioning of Micro Processor Controlled 1 x 5KVA standalone UPS ( Application: For Emergency Lighting, BMS, VAV & Security service loads) input supply of 415 Volts +/- 15%, 3 Phase, 50 Hz 10%, an out put of 415 Volts 1%, 3 Phase 50 0.1 Hz , Input Power Factor <=0.99, Input Total Harmonic Distortion (THDi) <2.5%, Unity Output Power Factor @ 35deg C consisting of Rectifier, Inverter, Battery DC Circuit Breaker with necessary MS enclosure, Inbuilt Static BYPASS( Input & output switches and Auto Static & Manual Bypass Switches), necessary cable alley shall be provided if cable entry/exit for UPS unit is from bottom/sides and necessary hardware & software for BMS Intergration with communication port RS 485 ( Status Monitoring ), all interconnecting Copper cables (Battery bank to Battery DC Circuit breaker, Battery DC Circuit breaker to UPS complete as required) with necessary adequate size of copper lugs etc., with necessary base channels/supports complete as required and all other necessary accessories required as per detailed specification. SECTION K : LIGHTNING PROTECTION All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. ADVANCED LIGHTNING PROTECTION SYSTEM

No.

492

493

84

Supply,Installation,Testing and commissioning of the Advanced Lightning Protection CSE Air Terminal with all accessories required for its proper functioning. The elevated pole should be fitted firmly attached to the wall or column with suitable guy wire system as per manufacturer recommendations to be provided. (Coverage 86m Radius) Supply,Installation,Testing and commissioning of the HVSC down conductor shall be consists of copper conducors, inner insulation, outer copper conductor, conductive sheaths, all cencentrically arrangements outer diameterr of the down conductor shall be less than 37mm. The main conductor cross sectional area is 50 sq.mm The down conductor shall be placed minimum wall thickness and minimum bending radius is 0.5m.The down conductor 50 sq.mm / 37mm / OD weight is 2.050 kg permetre.

Nos.

RMT

450

494

495

Supply,Installation,Testing and commissioning of the Lightning Strike Recorder designed for easy mounting on the down conductor to effectively count the number of liightning strikes captured by the air terminal. The recorder sensitive range of 1500 amps to a maximum of 220KA @ 8/20s. The recorder is self powered and does not require the use of battery or any other external power source etc. Supply,Installation,Testing and commissioning of efficient earthing system with copper bonded earth rod, Clamp, Copper Tape, Ground Resistance Improvement powder all as required including excavation of earth etc as required as per manufacture recommendation.(Tripod earthing with 3 Nos. of earth pit) Supply of 25x3mm copper Down Conductor Supply of tape clip for fastening the Down Conductor. Aviation Lamp Fittings: Supply, fixing of 2x12W LED cluster integral type aviation lamp at topmost height of the building with Auto ON / OFF photo cell controller, connecting wires upto aviation lamp including all connected accesories etc as per the specification. SECTION L : Solar system All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. The complete Solar PV system should have a warranty and after sales service for 5 years

Nos.

Nos.

496 497

RMT Nos

100 300

498

No.

499

Supply, erection, testing and commisioning of 15Kwp solar roof top grid tie system complete with all accessories and as mentioned below and as per the detailed technical specifications 250 Wp Solar Array (high efficiency multi crystalline modules) Galvanized MS Module mounting structure 15KWp,3Phase,415V,50HZ, Power Conditioning Unit with MPPT Solar Charge Controller and Data Logger Data logging and monitoring system Array & Main junction boxes AC Distribution panel Earthing Kit as per IS 3043 Lightning arrestor Installation Hardware Kit 1C x 4 sq.mm PVC Copper Cables 2C x 10 sq.mm PVC Copper Cables 3C x 25 sq.mm PVC Copper Cables Statutory permissions and approvals

No.

Electrical Works ( Interior Works ) SECTION M : SUPPLY AND FIXING OF LIGHTING LUMINAIRES & FANS All installation works should be as complete and as directed by Engineer-Incharge. The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Samples to be submitted and get approval fom Architect / Consultant before procurement For LED light fittings, the complete luminaire should have a warranty for 5 years which includes the housing + LED + Driver 500 Wipro WCP 37226 SGW or equivalent 2X26W CFL RECESS MOUNTED DOWNLIGHT LUMINAIRE WITH SATIN FINISH REFLECTOR Lamps: 2X26W CFL Wipro WCP 27218SGW or equivalent 2X18W CFL RECESS MOUNTED DOWNLIGHTER WITH FROSTED GLASS Lamps: 2X18W CFL Wipro WIF 20128SGW or equivalent 1X28W T5 SAVIOUR-SLIM ENERGY SAVING CHANNEL SUITABLE FOR FTL (T5) LAMP Lamps: 1X28W T5 Wipro WIF 30228SGW or equivalent 2X28W SAVIOUR - SLIM ENERGY SAVING CHANNEL SUITABLE FOR FTL (T5) LAMPS WITH BI-DIRECTIONAL REFLECTOR Lamps: 2X28W T5 Wipro WVF 22414SGW or equivalent 4X14W T5 RECESS MOUNTED DIRECT LIGHT LUMINARIE Lamps: 4X14W T5 Wipro GRP SGW 90226 or equivalent 2X26W CFL RHYTHM - PENDENT MOUNTED LUMINAIRE WITH PRISMATIC DIFFUSER Lamps: 2X26W CFL Wipro GCH 35070 or equivalent 1X70W KOMPASS UNO-RECESS MOUNTED METAL HALIDE DOWNLIGHTERS Lamps: 1X70W MH lamp Wipro GCH 35035 or equivalent 1X35W RECESSED GIMBALL LUMINAIRE Lamps: 1X35W MH lamp Wipro WIP 53236 SGW or equivalent 2X36W CFL SURFACE MOUNTED IP 54 BOTTOM OPENING TYPE CLEAN ROOM LUMINAIRE SUITABLE FOR CFL(TC-L)LAMP Lamps: 2X36W CFL Wipro WRF 80128 SG or equivalent Nos 296

501

Nos

520

502

Nos

152

503

Nos

108

504

Nos

564

505

Nos

26

506

Nos

30

507

Nos

96

508

Nos.

509

510

1X28W T5 INDOOR DECORATIVE LUMINAIRE SUITABLE FOR T5 LAMP Lamps: 1X28W T5 Wipro WVP 45218 or equivalent 2X18W CFL SURFACE MOUNTED MIRROR OPTIC LUMINAIRE WITH PARALITE P5 LOUVRES Lamps: 2X18W CFL Wipro WVF 48228 SGW or equivalent 2X28W T5 SURFACE MOUNTED LUMINARIE WITH UNIQUE DUAL FINISH LOUVRE SYSTEM SUITABLE FOR FTL(T5) LAMP Lamps: 2X28W T5 Wipro WDF 9128 SG or equivalent Wall light patti fitting Lamps: 1X28W Wipro WRP 21111 or equivalent Mirror light fitting (2feet patti fitting) Lamps: 1X11W CFL Wipro WKP 14 or equivalent Bulk head fitting Lamps: 1X9W CFL Wipro WFH51150 or equivalent or equivalent Compact Sturdy general purpose floodlight with integral gear, housing made of non-corrosive, high pressure die cast aluminium with low copper content and black powder coated finish, heat resistant EPR gasket with IP-65 suitable for use with High Pressure Metal Halide MHNTD 150W lamp Lamps: 1X150W MHL Bajaj BRBOL 118 or equivalent Renaissance - Integral Bollard with cylindrical shape housing, spun aluminium hat shape top cover fixed with clear acrylic cover Lamps: 1X18W CFL Bajaj BECBL 03 126 CFL B or equivalent Renaissance - Integral Bollard with black epoxy powder coated cylindrical bollard with antiglare louvers diffuser in clear acrylic cover. Lamps: 1X26W CFL Similar to Wipro LD70-400-XXX-27-XX (Spotz LED) Efficacy > 100lumens / watt Color temperature: 2700 deg Kelvin High efficiency Prismatic collimator lens for better light distribution Black anodized aluminium heat sink for effective heat dissipation Aesthetically textured chrome plated bottom Finish Lamps: 1 X 4W LED

Nos

10

Nos.

511

Nos

45

512

Nos

601

513

Nos

86

514

Nos

145

515

Nos

15

516

Nos

30

517

30

518

Nos

25

519

520

High performance PIR occupancy presence detectros for automatic control of lighting. Shall have adjustable off delay timing varying from 10 sec to 99 min. Advance PIR sensor for occupancy and vacancy sensing with built-in switching photo cell detector for daylight detection. Sensor has 2 way programming feature using knobs provided on the sensor or with hand held IR device. The sensitivity of the sensor can be adjusted in 9 different steps. The sensor has in built IR receiver to be operated using hand held IR remote control. Similar to WIPRO: COP 11010 Sliding type dimming system with select light level with slider - slide up to brighten, down to dim. Suitable for 010 V dimmable fluorescent ballasts.Rated for maximum 20 ballasts/40 mA control current.Requires mains voltage occupancy sensor by another manufacturer to power ballasts. Similar to WIPRO: LSTV-F20B-FAW-M High performance PIR occupancy presence detectros for automatic control of lighting. Shall have adjustable off delay timing varying from 10 sec to 99 min. Advance PIR sensor for occupancy and vacancy sensing with built-in regulating photo cell detector for daylight detection. Sensor has 2 way programming feature using knobs provided on the sensor or with hand held IR device. The sensitivity of the sensor can be adjusted in 9 different steps. The sensor has in built IR receiver to be operated using hand held IR remote control. Suitable for analogue dimming. Similar to WIPRO: CDA 13010 Supply, fixing, testing and commissioning of 1200mm sweep single phase ceiling fan with standard down rod, similar to Bajaj Elctra 50 (White). Supply, fixing, testing and commissioning of 600mm sweep single phase ceiling fan with standard down rod, similar to Bajaj Maxima 600mm (White). Supply, fixing, testing and commissioning of 300mm dia light duty single phase exhaust fan for toilets, Similar to Bajaj Maxima DX (White). Supply, fixing, testing and commissioning of 1400 RPM heavy duty 380 mm dia single phase exhaust fan with louvers. Supply, fixing, cutting, threading and fixing of 25 mm MS conduit for fixing of down rods, including check nut, ball and socket etc. after the installation the pipe shall painted with required colour as required at site condition. Supply and fixing chain suspender with suitable anchor platners for mirror optics light fititngs in office floors. SECTION N : SUPPLY AND FIXING OF SPECIAL LIGHTING LUMINAIRES All installation works should be as complete and as directed by Engineer-Incharge.

Nos

100

Nos

10

521

Nos

50

522

Nos

506

523

Nos

66

524

Nos

241

525

Nos.

526

RMT

2000

527

RMT

2000

The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. Samples to be submitted and get approval fom Architect before procurement Type-C, Bachelor and Transit accomodation (Option-1) 528 Entrance light above door The Ledino flush wall bracket is a futuristic themed light. The half bowl fitting is finished in white and features a hollowed out space into which 2 down lights shine. The fitting measures 13.1cm in diameter and protrudes from the wall 6.5cm. The light comes complete with 2 x 2.5w LED bulbs. Similar to Philips Reference.No: 69085/31 Ceiling lights Aluminum E27 Max 1 x 100W Material Glass withouth Lamp Similar to Philips Reference.No: QCG 301 Wall lights E27 Max 1x60W Material Glass withouth Lamp Similar to Philips Reference.No: QWG 301 Balcony lights Material Synthetic, Color White IP20, Lamp Included, 1x22W 230V Similar to Philips Reference.No: 30161 Toilet mirror light Mirror lamps chrome 1x8W 230V - Chrome finish Similar to Philips Reference.No: FWZ 300 Store light Aquafit QCZ801 G9, Max. 1x 25W - Chrome finish Similar to Philips Reference.No: QCZ801 Toilet down lighter Genie E27, 14W not included,With toughened glass cover, finish -nickle satin Similar to Philips Reference.No: FBG302 Type-C, Bachelor and Transit accomodation (Option-2) Entrance light above door Wall light - Material Metal,Color white,On/off switch on article, IP code: IP20, protection against objects bigger than 12.5 mm, no protection against water,Wattage bulb included: 2.5 W, Light color 4000K cool white Similar to Philips Reference.No: 33257 Ceiling lights Ceiling Light - Material Glass, color gold E27, 1Normal Lamp, Lamp Excluded, Non Dimable Similar to Philips Reference.No: QCG 309 Wall lights

Nos

32

529

Nos

352

530

Nos

224

531

Nos

64

532

Nos

128

533

Nos

64

534

Nos

64

535

Nos

32

536

Nos

352

537

538

539

540

541

542

Wall Light - Material Glass, color gold E27, lamp 1x60W,Lamp Excluded, Non Dimable Similar to Philips Reference.No: QWG 315 Balcony lights Ceiling Light, Balcony Garden,Material - Steel, Color White,Lamp Excluded, Non Dimable Similar to Philips Reference.No: ECB 300 Toilet mirror light Mirror lamps chrome 1x8W 230V - Chrome finish Similar to Philips Reference.No: FWZ 300 Store light Aquafit QCZ801 G9, Max. 1x 25W - Chrome finish Similar to Philips Reference.No: QCZ801 Toilet down lighter Genie E27, 14W not included,With toughened glass cover, finish -nickle satin Similar to Philips Reference.No: FBG302 Type-D & VIP rooms Entrance light above door Wall light - LED 2.5 W, Material: Glass, Color: Chrome, premium Quality,Energy saving: 80 %, Lamp Included Similar to Philips Reference.No: 37242 Ceiling lights living (double ht) Pendant Light FPG701 Material Steel, Finish Aluminum Suspension Light, Lamp included , base cap 2GX13 Similar to Philips Reference.No: FPG701 Ceiling lights Ceiling Light - 37246 ceiling lamp chrome 9x2.5W SELV,Material: Glass, Color: Chrome, premium Quality,Energy saving: 80 %, Lamp Included Similar to Philips Reference.No: 37246 Wall lights Wall light - LED 2.5 W, Material: Glass, Color: Chrome, premium Quality,Energy saving: 80 %, Lamp Included Similar to Philips Reference.No: 37242 Toilet Mirror Light Mirror Light cap: GX53,Wattage bulb included: 9 W,Light color: 2700K warm white,IP code: IP44, protection against objects bigger than 1 mm, protection from splashed water, Material Metal, color chrome Similar to Philips Reference.No: 34312/11 Balcony lights Ceiling Light, Balcony Garden,Material - Steel, Color White,Lamp Excluded, Non Dimable Similar to Philips Reference.No: ECB 300 Store light Aquafit QCZ801 G9, Max. 1x 25W - Chrome finish Similar to Philips Reference.No: QCZ801 Toilet down lighter

Nos

224

Nos

64

Nos

128

Nos

64

Nos

64

Nos.

543

Nos.

544

Nos

20

545

Nos

31

546

Nos.

547

Nos

14

548

Nos.

549

550

551

552

553

554

555

556

Genie E27, 14W not included,With toughened glass cover, finish -nickle satin Similar to Philips Reference.No: FBG302 OFFICE AREA Mouette (Reference.No: L 860710) Extruded aluminium structure; rotational moulded polypropylene diffuser; steel suspension wires Max 1900mm to use 4 x 24w T5 tubes with Dali Dimmable Ballst. Similar to Artemide (Light Art) or equivalent Channel (Reference.No: 436LEV.128X.8) Recessed Fixture with Aluminium profile,trim, Acrylic diffuser and Dali Dimmable ballast for 1 x 28w T5 tube Similar to Regent (Light Art) or equivalent Umbrella (Reference.No: 00-2727-AP-05) Pendant in Black lacquered body,Golden pleated interior shade and frosted glass at bottom to hide the lamp to use 3 x max 14w CFL. Similar to LEDSC-4 (Light Art) or equivalent Castor (Reference.No: 8332) Pendant with white base and opal glass for E27 max 27w Spiral CFL. Similar to Light Art or equivalent Castor (Reference.No: 8333) Pendant with white base and opal glass for E27 max 27w Spiral CFL. Similar to Light Art or equivalent Castor (Reference.No: 8334) Pendant with white base and opal glass for E27 max 27w Spiral CFL. Similar to Light Art or equivalent Similar to Ligman Mustang 34 largw single tennis court luminaire (Catalogue.No:93051-SC76) Large size rectangular shape area light distribution for metal halide lamps or sodium vapour discharge lamps 70400w. A high quality reflector design creates broad spread light distribution. Main application for lighting of public, private roadways, car parks, exhibition areas, service stations, truck stop and sports grounds. Aluminium housing with high corrosion resistance. Stainless steel screws. Durable silicone rubber gasket and clear toughened glass with hinge aluminium frame for inposition lamp replacement. Anodized high purity aluminium reflector. Main housing is powder paint with high corrosion resistance with chemical chromatised protection. Lamps: HIT 1000W SCHEDULE - F - DG Works DG SET WITH SCRUBBER, EXHAUST STACK AND CONNECTED WORKS

Nos

10

Nos.

Nos

52

Nos.

Nos.

Nos

Nos

Nos

All installation works should be as complete and as directed by Engineer-Incharge. 557 Supply, Installation, Testing and Commissioning of factory assembled and factory tested, water cooled, turbo charged after cooled diesel engine alternator set capable of generating full load of 1250 KVA capacity at 40 C, power factor not less than 0.8 lag, 415 Volts, 1500rpm, 3 phase, 50 Hz, AC supply and driven with diesel engine complete with all accessories such as Base frame, residential silencer, radiator, alternator capable of delivering 415 Volts, 50Hz, 3 phase, PF 0.8, 1250 KVA load, coupling arrangement of alternator with engine, coupling guard, water pump, oil pump, fuel filter, oil filter, air filter, exhaust flexible piping, fuel tank (990 Litres capacity of day tank), fuel transfer hand pump with suitable hose pipe, battery 24 Volts and 200 AH capacity, battery charging alternator, engine control panel, anti-vibration spring type mounting (quantity as per the manufacturers recommendation), conducting of trial run and A/T as per special conditions Suitable for acoustic enclosure installation but without acoustic enclosure and standard type of engine alternator control panel etc. complete as per specifications. (Excluding cost of foundation). Note : The sucessful tenderer should confirm that the engine model shall be capable of delivering minimum 1250KVA and suitable for delivering 1250 KVA when coupled with alternator given below at site condition as required. The Acoustic Enclosure is included seperately. 558 Supply, Installation, Testing and Commissioning of acoustic enclosure suitable for 1 No. 1250 KVA radiator water cooled diesel generator with all accessories fabricated with 16 SWG CRCA sheet steel, mineral wool insulation of high density with perforated GI sheet covering, ventilation system complete with fans and louvers, doors, inside temperature controller, inside illumination with energy efficient T5 fluorescent fittings, wiring for light and plug points with suitable size and number of PVC insulated copper conductor cable on surface MS conduit system, i/c. MCB type distribution board, earthing complete as per the Specification and the drawing enclosed.(The above enclosure should be as per CPCB norms. The current approval certificate shall be submitted by the firm).The day tank of 990 Litres shall be mounted on a suitable pedestal with weather proof enclosure nearer to the DG set. (Excluding cost of foundation). The necessary details such as weight(dynamic & static weight), sizes shall be furnished for the execution. Nos. 2 Nos. 2

559

Supply, Installation, Testing and Commissioning of Control panel indoor, floor mounting type with 2000Amps, 4pole 65KA ,EDO type ,air circuit breaker with shunt release, shutter assembly, door interlock and other required accessories, complete set of instrument panel,protection release/relays, auto start/stop arrangement as per detailed specification.The panel shall be installed inside the acoustic enclosure. Supply,Installation, Testing and Commissioning of AMF with Auto Synchronising control panel with Auto Load sharing arrangement of indoor, floor mounting type with 2 Nos. 2000Amps, TP, 65KA ,EDO type ,air circuit breaker with shunt release, shutter assembly, door interlock and other required accessories and 250Amps,4 pole, neutral isolating contactor as incoming with complete set of instrument panel with accessories, protection release/relays etc. and 1No. 4000Amps, 4pole, 75KA, EDO ACB with shunt release, shutter assembly, door interlock and other required accessories as bus coupler & 2 Nos. 2000Amps, 4Pole, 65KA ,EDO type ,air circuit breaker with shunt release, shutter assembly, door interlock and other required accessories as outgoing feeders with complete set of instrument panel with accessories, protection release/relays etc.

Nos.

560

No.

561

and necessary electrical interlocking arrangement between incomer and bus coupler by hardware control wiring along with PLC (Programmable Logic Control). The hardware control wiring for MPCC, AMF Panel, Capacitor Panel, Auto Synchronisation Panel and other necessary control wiring and PLC operation shall be feasible to extend for the panel as per the detailed specification and drawings enclosed. Supply, installation, Testing and Commissioning of wet scrubber with packing media and connected accessories like scrubbing tank 1No., scrubbing pumps 2Nos. (1 main and 1standby) interconnecting pipe line works with all accessories and control valves, suitable supports for the scrubber, required ducting for the scrubber assembly i/c. dampers for bypass arrangement, neutralisation system, suitable for 3Nos. 1250KVA DG set ( 2 Nos. at present + 1 No Future), hot gas inlet and outlet arrangements, online PH monitoring and connected electrical works i/c. control panel, earthing, starter for pump sets, control and power copper cabling, minor civil works, painting, sign writing complete as per specification and drawings enclosed etc. as required. (Excluding cost of foundation).

No.

562

563

564

Supply and Laying of 50mm x 10mm copper flat from earth electrode in 80mm dia B class GI, directly in ground including earth work excavation, refilling the trench, with all accessories, jointing the flats with lap joint with 2Nos. of bolt/nuts/spring washers/check nuts completed etc. as required. Supply and fixing of earthing station with 2Nos X 600mm x 50mm x 12.5mm copper busbar on suitable No. of supporting insulators having machine made holes for incoming/outgoing earth flats, painting and sign writing etc as required. Supply and fixing of 10" dia MS exhaust pipe class B suitable for 1250 KVA engine exhaust line including with all accessories such as bends,.flanges, gaskets, condensation removal plug, fixing of flexible coupling, residential silencer supplied along with the engine. Providing necessary MS angle iron supports for the pipe line and the silencer, welding arrangements/ flanged joints with bolts/nuts as per the site conditions. Terminating the pipe line/ ducting in scrubber and chimney including the complete pipe line/ duct of insulation with 50mm thick glass wool, polythene covering,chicken mesh and aluminium cladding complete as per the specifications etc. as required. Supply and fixing of 14" dia MS exhaust pipe class B suitable for 1250 KVA engine exhaust line including with all accessories such as bends,.flanges, gaskets, condensation removal plug, fixing of flexible coupling, residential silencer supplied along with the engine. Providing necessary MS angle iron supports for the pipe line and the silencer, welding arrangements/ flanged joints with bolts/nuts as per the site conditions. Terminating the pipe line/ ducting in scrubber and chimney including the complete pipe line/ duct of insulation with 50mm thick glass wool, polythene covering,chicken mesh and aluminium cladding complete as per the specifications etc. as required. Supply & fixing of 50mm thick glass wool insulation for the 1250KVA engine residential silencer including cutting, fixing of glass wool, polythene covering,chicken mesh and aluminium cladding complete as per the specifications etc. as required. Supplying and laying of 25mm dia , B class MS pipe, fuel line for the interconnection of the reserve tanks to day tank and day tank to engine i/c. fuel transfer pumps with all accessories such as bend,elbow, coupling, union, plugs,flanges,bolts/nuts,gaskets, making threaded ends/welding as per the site condition laying in the following manner etc. as required. In the exposed surface the pipe line shall be painted with one coat of primer and two coats of synthetic enamel paint i/c. with necessary supports complete as required.

RMT

50

No.

RMT

16

565

RMT

60

566

Nos.

567

RMT

40

568

In soil , below 0.5 Mtrs from the ground level , the pipe line shall be painted with one coat of hot bitumen,wrapping with 3 layers of hessian cloth dipped in hot bitumen i/c. with necessary supports complete etc. as required. Supplying and fixing of outdoor weather proof reserve fuel day tank made up of 3mm thick MS sheet, 990 ltrs capacity i/c. cutting, welding,grinding,providing inlet,outlet, overflow, drain, air vent, inlet fuel filter, fuel level indicator with scale, painting,fixing with suitable size MS angle iron frame work on the existing foundation etc. as required. (Excluding cost of foundation). Supply, Installation,Testing and commissioning of fuel transfer pumps 1 HP capacity, self priming, flame proof pumps 2Nos. (1No. Main and 1No. Standby) i/c. installation of pump sets on the existing foundation, connected fuel pipe line work with necessary control valves, to fill the reserve tank from barrels and to fill the day tanks from the reserve tanks i/c. all electrical works such as control MCB, starter,changeover switch, control and power wiring with PVC insulated copper conductor cabling, end terminations, earthing the pumps,painting,sign writing and complete as required. (Excluding cost of foundation). Supply and laying of the following PVC insulated, PVC sheathed armoured Copper conductor cabling from engine control panel to AMF control panel and battery charger, day tank with suitable clamping arrangement, end terminations, earthing the glands, laying on the existing cable tray /trench, painting complete etc. as required. 16 Core X 2.5Sq.mm Copper cable Supply and fixing 200mm width cable tray suspended from the ceiling or supported from the ground with suitable angle iron supports. The tray shall be made up of 38mmX38mmX5mm MS angle iron and interconnected with 2Nos.X25mmX3mm MS flat at every 150mm interval with necessary painting with one coat of red oxide paint and two coat of enamel paint etc. as required. Supply and fixing of 1200mm X 600mm size 22 guage GI sheet board for display the name plate details of DG set with suitable frame work i/c. fixing on the accoustic enclosure, painting,sign writing etc. as required. Supply, Installation, Testing and Commissioning of the structrual stack height of 30 mtr from ground level using various size of GI channels and Supports of Residential Silencer, Fuel Pipe and busduct etc. Detailed design along with all calcuation details shallbe submitted by the sucessful vendor. The rate shall inclusive of foundation bolt, base plate for the stack etc.

RMT

30

Nos.

569

Nos.

570

571

RMT RMT

100 100

572

Nos.

573

MT

12

574

Lift Works LIFT AND ELEVATOR PASSENGER LIFT Supplying, installation, testing & commissioning of Passenger lift for various buildings of standard design conforming to latest lift act and modern lift with microprocesor including AC- Gearless synchronous V.V.V.F drive system in the existing lift well / shaft having the following speed, travel and stops for various buildings. The lift car interiors such as car enclosure,ceiling, handrailing,door panelling,Jambs in all floors,fan, car light and others shall be complete as per specification and two hours fire rated for landing doors. The lift shall be of excellent quality and shall have luminous white square flush mounted Braille push buttons,intelligent group controls of four lifts, floor announcement system, Gearless and other features as per detailed specifications attached. The lift car shall have two parallel car operating control panels in automatic mode with or without attendant (duplex mode). The lift equipment being machine room the machine will be fixed on the guide rail and machine room less elevator lift assemble within the hoist way at the last landing. All the lift equipments, i/c car, car doors self-levelling devices, control devices, indicators, landing doors, indicators, terminal buffers,hoisting suspension ropes shall be of steel of suitable size for safety devices i/c all wiring connection, interconnection and all connected equipments shall be as per specifications. The work also includes all structural items in machine room and above the lift well like RCC block, & MS girders required for lift insallations & providing miscellaneous items like supports for guide rails, overhead gears, scaffoldings, sill projections, facia inside the lift well, minor building works like making sockets, holes etc. i/c making good the damages. The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift, as complete in all respects complying with all relevant standard specification and as directed by the Engineer-Incharge.

13 passenger of 884kgs without Machine room of minimum speed of 2.0m/sec (min) with a total travel of 53.60 mtrs. Stilt plus 18 floors servicing 19 stops and 19 landings on same side. 13 passenger of 884kgs without Machine room of minimum speed of 1.5m/sec (min) with a total travel of 32.95 mtrs. Ground plus 11 floors servicing 12 stops and 12 landings on same side.

Nos.

Nos.

575

6 passenger of 408kgs without Machine room of minimum speed of 1.0m/sec (min) with a total travel of 12.6 mtrs. Ground plus 3 floors servicing 4 stops and 4 landings on same side. SERVICE LIFT Supplying, installation, testing & commissioning of Service elevator for various buildings of design conforming to latest lift act and modern lift with including AC Gearless synchronous digitalised microprocessor based programmable VVVF controller in the existing lift well / shaft having the following speed,travel and stops for various buildings. The lift shall be complete with factory enamelled / MS paint finish for car enclosure, ceiling & car doors (all four sides) and landing doors shall be opening telescopic stainless steel door (two hours fire rated) and three sides guard rail,handle inside the car. (with all car interiors complete as per specification) The lift shall be of excellent quality and shall have luminous white square flush mounted braille push buttons, intelligent group of simplex controls,collective, floor announcement system, Gearless machine and other features as per detailed specifications attached. The lift car shall have car operating control panel (1no) in automatic mode (with or without attendant) and from one panel in attendant mode. The lift equipment will be installed in the machine room directly above the lift well and machine room less elevator lift assemble within the hoist way at the last landing. All the lift equipments, i/c car, car doors self-levelling devices, control devices, indicators, landing doors, indicators,terminal buffers,hoisting suspension ropes shall be of steel of suitable size for safety devices i/c all wiring connection, interconnection and all connected equipments shall be as per specifications. The work also includes all structural items in machine room and above the lift well like RCC block, & MS girders required for lift insallations & providing miscellaneous items like supports for guide rails, overhead gears, scaffoldings, sill projections, facia inside the lift well, minor building works like making sockets, holes etc. i/c making good the damages. The rate shall include approval / obtaining completion certificate from the electrical / lift inspectorate of Local Competent Electrical Authority for installation and commissioning of lifts before handing over the entire installation of the lift, as complete in all respects complying with all relevant standard specification and as directed by the Engineer-incharge

Nos.

One Service Elevator of 1420 kgs without Machine room of minimum speed of 1.0m/sec (min) with a total travel of 12.60 mtrs. Ground plus 3 floors servicing 4 stops and 4 landings on same side.

Nos.

I 576

One Service Elevator of 1360 kgs with Machine room of minimum speed of 1.0m/sec (min) with a total travel of 6.00 mtrs. Ground plus 1 floors servicing 2 stops and 2 landings on same side. HVAC Works (Heat Ventilation & Air-Conditioning) AIR COOLED SCROLL CHILLERS Design, supply, customs clearance , freight upto site, Insurance, delivery, hoisting, installing, testing and commissioning of the following items as shown on the equipment data and drawing for complete and satisfactory operation and control and to local authorities approval. The units shall be anti-corrosive suitable for coastal area application. BMS interfacing type microprocessor controlled Roof top air-cooled liquid chiller package suitable for refrigerant R410A or R407c having multiple scroll type compressors (hermetic type) with hydronic pumps (1W+1Standby), unit mounted starters, controllers and complete as per specification. The rate shall inclusive of vibration isolators (moulded elastomeric isolators) to arrest noise and vibration. Chillers capacity of each chilling unit will be as follows:

Nos.

577

Capacity : 40 TR (minimum) at 40C Ambient Nos. Water in : (+) 12 Deg C Water Out : (+)7 Deg C Fouling factor : 0.0001 FPS units Flanges of resilent vibration isolating material (like rubber for example) at the inlet and outlet of chillers and pumps along with necessary bushes-also of similar material to minimize transmission of vibration to connected piping. 65NB Necessary sockets and nipples with shut off valves for mounting sensors/transmitters on pipe line to interface the BMS system. Supply,installation testing and commissioning of Chiller isolator panel outdoor type suitable for 40 TR Air cooled scroll cooled chiller with isolator Supply, fabrication and erection of grating from the curb of pedestal to provide easy and trouble free access, weather protective cowl for electrical panel and all special tools and tackles for operation, assembling, commissioning and maintaining the chiller unit. It shall be supplied / provided by the ACMV Contractor. AIR HANDLING UNITS AND ENERGY RECOVERY UNIT AIR HANDLING UNITS - FLOOR MOUNTED TYPE Nos. Set

578

9 1

579

No.

580

Kg

500

II 581

Supply, installtion, erection testing and commissioning of Double Skin floor mounted AHU with 6 Row cooling coils (copper tubes with Aluminium fins construction) flat filters section with 48 mm thick Non-woven synthetic pre filter, medium pressure fan section with centrifugal fan/s, sq.cage induction motor belt drive, belt guard, vibration isolators, double canvas connections and with unit mounted emergency off station internally factory wired between motors and emergency off station as per specifications. Frame of anodised extruded aluminium thermal break sections and bolted together with cast aluminium, fittings provided at joints and the entire unit is supported on painted steel channel frame. All the section shall be thermal break as the AHU is outdoor type. Casing panels shall be of insulated sandwich made of 0.6mm thick powder coated or plasticised sheet outside shall be suitable for out door application and 0.6mm thick galvanised sheet steel inside with 50mm thick Puf insulation media in between. One section of panel to another and panel to frame work are bolted together with leak proof soft neoprene rubber gasket to prevent any air leakage. Air tight access doors with adjustable tension locking device for inspection wherever required. Common channel base to mount fan and motor assembly with vibration isolator for smooth vibration free operation. The double skin air handler shall include for the following and its final painting to code. Low leaking volume control damper in 1.6mm galvanised / aluminium aerofoil blade, 16mm dia plated steel stubs locked to the blades with mechanical fasteners, heavy duty moulded nylon bearings, neoprene rubber seals at tips, aluminium compression seals at jambs, brass rollers, double linkage on panels over 1000mm in width etc. Flexible connections at fan outlet constructed of the fireresistant flexible double canvass sleeve as per the specification. The price shall also include the following. a) All internal wiring between limit switch and marine lights, power cabling copper earthing of air handling unit motors, from the local control panel and control wiring b) Bimetallic lugs shall be used at copper to aluminium joints. c) Accessories and associated wiring between fire damper panel to fire damper and AHU motor to close fire dampers and shut-off AHU motor in the case of fire. AHU Specifications: Location-Terrace Floor Cooling Capacity : 40.0 TR (Outdoor type) Dehumidified air quantity :13600 CFM

No.

582

Chilled Water flow rate : 96.0 GPM ENERGY RECOVERY UNIT Supply,installation, testing and commissioning of Energy recovery unit consists of exhaust air block and fresh air block. Each block is made up of double skin construction designed on modular concept basis and has provision for fan , motor, damper and filter. Each block module shall be fitted with other block, housing heat recovery devices, washable metallic viscous filters (50mm thick) and inlet and outlet dampers (extruded aluminium low leakage construction) with bird screen for supply and return air. Air flow parameters: Energy recovery unit complete with desiccant coated aluminium media rotor seal GI structural frame work to house rotor, drive system, rotor drive motor, belt, pre-filter complete with starter panel. The price for energy recovery unit shall include the following a) All internal wiring, power cabling copper earthing of treated fresh air unit motors, from the panel and control wiring b) Bimetallic lugs shall be used at copper to aluminium joints and as per specification.

The vendor shall select the suitable units with minimum leakage. The fresh air quantity required after leakage is as follows. 5220 cfm (Supply air fan and return air fan) -Outdoor type No. ESP - 500 Pa for fresh air supply fan and 500 Pa for return air fan VRV SYSTEM Supply, Installation, testing and commissioning of VRV Indoor air conditioning units with direct driven fan, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, wired PID remote controller, drain pump, necessary ceiling supports & vibration isolators, refrigerant charging, oil charging, control wiring and drain connection, etc. The capacities and cfm are as mentioned below:Multi Flow Cassette Units (Round/4-way) (VRV) Cooling Capacity: 39,600 Btu/hr Air Flow : 1130 cfm Cooling Capacity: 31,700 Btu/hr Air Flow : 742 cfm Cooling Capacity: 24,900 Btu/hr Air Flow : 671 cfm Cooling Capacity: 19,800 Btu/hr Air Flow : 565 cfm Cooling Capacity: 16,000 Btu/hr Air Flow : 530 cfm Cooling Capacity: 12,600 Btu/hr Air Flow : 459 cfm Cooling Capacity: 9,900 Btu/hr Air Flow : 459 cfm 2-Way cassette units (VRV) Cooling Capacity: 19,800 Btu/hr Air Flow : 424 cfm Cooling Capacity: 16,000 Btu/hr Air Flow : 424 cfm Cooling Capacity: 12,600 Btu/hr Air Flow : 318 cfm Cooling Capacity: 9,900 Btu/hr Air Flow : 318 cfm Ceiling Suspended unit (VRV) Cooling Capacity: 39,600 Btu/hr Air Flow: 883 cfm

III 583

a i ii iii iv v vi vii b i ii iii iv c

Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos. Nos.

11 23 8 20 20 33 67 2 16 5 9 4

d i ii 584

Ceiling Mounted Ductable units (VRV) Cooling Capacity: 57,000 Btu/hr Air Flow: 1624 cfm Cooling Capacity: 78,500 Btu/hr Air Flow: 2047 cfm Supply, Installation and commissioning of energy recovery unit combined with supply air fan, return air fan, suitable heat exchanger elements with necessary supports, cabling, steel frame works etc.The capacity of energy recovery unit as mentioned below Air Flow : 325 - 382 cfm Air Flow : 400 - 471 cfm Air Flow : 500 - 588 cfm Supply, Installation, testing and commissioning of Outdoor units consists of minimum one no of inverter scroll / rotary compressor, constant speed scroll compressors, DC fan motor with aero-spiral fan blade, epass heat exchanger, safety valves, solenoid valves, receiver, capilary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator and outdoor refnet kits. Rate inclusive of R410A / R-407C / equivalent refrigerant for entire circuits & oil pre charging, vibration isolators, supports, necessary civil works for fountation/pedestal/steel frame works, etc. 18 HP 28 HP 34 HP 36 HP 38 HP 40 HP 48 HP Supply and installation of central remote controller - I touch screen controller suitable to connect upto multiple indoor and outdoor units (including integration with fire alarm system, operate or monitor on / off, temperature setting etc.,) individually. The controller shall compatible to connect with BMS. Supply and installation of Refnet joints (Refrigerant branch kit) for taking branches between two outdoor units and various indoors as per VRV scheme drawings. The refnet joint set consists of both liquid and gas line branch kits. The Refnet joint model name as follows. 22T 33T 72T 73T + 73T Supply and erection of 16 Gauge Hard drawn Refrigerant Copper pipes to integrate outdoor / indoor units. The rate shall inclusive of closed cell nitrile rubber insulation for copper pipes. The pipe sizes and insulation thickness as follows. 6.4mm dia with 9mm thick insulation

Nos. Nos.

2 1

a b c 585

Nos. Nos. Nos.

2 3 14

a b c d e f g 586

Nos. Nos. Nos. Nos. Nos. Nos. Nos. Lot

1 2 1 1 1 1 3 1

587

a b c d 588

Nos. Nos. Nos. Nos.

60 24 55 72

RMT

699

b c d e f g h i j k l 589

9.5mm dia with 9mm thick insulation 12.7mm dia with 13mm thick insulation 15.9mm dia with 13mm thick insulation 19.1mm dia with 19mm thick insulation 22.2mm dia with 19mm thick insulation 25.4mm dia with 19mm thick insulation 28.6mm dia with 19mm thick insulation 31.7mm dia with 19mm thick insulation 34.9mm dia with 19mm thick insulation 38.4mm dia with 19mm thick insulation 41.3mm dia with 19mm thick insulation Supply and laying of 2C x 1.5 Sqmm PVC Copper Armoured Cable - Communication and Control cabling between indoor and outdoor units. The rate shall be including suitable size MS conduit with conduit accessories and necessary fixing arrangement. Supply and laying of 2C x 0.75 Sqmm PVC Copper Armoured Cable - Control cabling for wired remote controller.(optional) Supply and fixing in position of Heavy duty PVC pipe cut to required length with 9mm thick nitrile rubber insulation, installed with all joints, reducer, necessary elbows and tees. 40 NB 25 NB VRV SYSTEM SUMMARY DX SYSTEM DUCTABLE SPLIT UNITS Supply,Installation,testing and commissioing of Ceiling mounted ductable splitunits of specified capacities with R410A / R-407c refrigerant gas filling. The indoor units shall be ceiling mounted duct type. The Indoor unit shall comprise of Fan, Cooling coil, Filter and Expansion device. The Outdoor unit shall comprise of scroll / rotary Compressors, Air cooled condenser & Condenser fan. If multiple compressors are offered, they shall have independent refrigerant circuits. Also, compressors shall be cut-off automatically under part load conditions. The units shall have microprocessor controls. The outdoor unit shall be installed in the terrace level. The rate shall inclusive of control wiring between indoor and outdoor units, refrigerant charging, insulated drain pipes and supports for the indoor and outdoor units. The units shall be selected for chennai Ambient conditions. The units shall be factory assembled and only the refrigerant piping carried out at site.it is inclusive of cabling between indoor and outdoor units and earthing of indoor and outdoor units. Cooling Capacity: 1,32,000 Btu/h Air flow: 4400 cfm Cooling Capacity: 1,02,000 Btu/h Air flow: 3400 cfm Cooling Capacity: 45,000 Btu/h Air flow: 1235 cfm

RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT RMT

342 916 358 247 335 59 8 141 16 153 128 1750

590

RMT

1070

591

a b IV 592

RMT RMT

562 596

a b c

Nos. Nos. Nos.

1 1 1

593

HI WALL SPLIT UNITS Supply and Installation of Hi-Wall Split air conditioning units of specified capacities with R410A/R407C refrigerant gas filling.The indoor units shall be wall fixing type. The Indoor unit shall comprise of Blower, Cooling coil, Filter and Expansion device. The Outdoor unit shall comprise of inverter scroll / rotary Compressor, Air cooled condenser & Condenser fans. The outdoor unit shall be installed at terrace level.Scope shall include all supports for the indoor and outdoor units. The units shall be selected for Chennai Ambient conditions as specified.Rate inclusive of suitable voltage stabilizer,cabling 20 Amps contactor with NO+NC (for remote operation through BMS) and control cable.

a b c d 594

Cooling Capacity: 36,000 Btu/hr Air flow: 811 cfm Cooling Capacity: 24,000 Btu/hr Air flow: 670 cfm Cooling Capacity: 18,000 Btu/hr Air flow: 572 cfm Cooling Capacity: 12,000 Btu/hr Air flow: 350 cfm CASSETTE UNITS Supply, Installation and commissioning of DX Cassette units of specified capacities with R410A/R407C refrigerant gas filling. The Indoor unit shall comprise of 4way air flow Blowers, Cooling coil, Filter and Expansion device and drain pan. The Outdoor unit shall comprise of inverter scroll Compressor, Air cooled condenser & Condenser fans. The outdoor unit shall be installed at terrace floor level. Scope shall be inclusive of suitable voltage stablizer, all supports for the indoor and outdoor units. The units shall be selected for chennai Ambient conditions as specified. Rate inclusive of 20 Amps contactor with NO+NC (for remote operation through BMS) and suitable earthing of indoor and outdoor units.

Nos. Nos. Nos Nos.

2 3 32 2

a b c 595

Cooling Capacity - 36,000 Btu/hr Air Flow -988cfm Cooling Capacity - 24,000 Btu/hr Air Flow -670cfm Cooling Capacity - 18,000 Btu/hr Air Flow -529cfm HI SENSIBLE FLOOR MOUNTED PACKAGED UNITS

Nos. Nos. Nos.

3 2 8

Supply,Installation,testing and commissioing of Hi sensible floor mounted ductable packaged units of specified capacities with R-410A / R-407c / Equivalent refrigerant gas filling. The indoor units shall be floor mounted packaged type. The Indoor unit shall comprise of Fan, Cooling coil, Filter and Expansion device. The Outdoor unit shall comprise of Hermetic scroll Compressors, Air cooled condenser & Condenser fan. If multiple compressors are offered, they shall have independent refrigerant circuits. Also, compressors shall be cut-off automatically under part load conditions. The units shall have microprocessor controls. The outdoor unit shall be installed in the terrce level. The rate shall inclusive of control wiring between indoor and outdoor units, refrigerant charging, insulated drain pipes and supports for the indoor and outdoor units. The units shall be selected for chennai Ambient conditions. The units shall be factory assembled and only the refrigerant piping carried out at site.it is inclusive of cabling between indoor and outdoor units and earthing of indoor and outdoor units. Cooling Capacity: 1,98,000 Btu/h Air flow: 8250 CFM (2w+1s) Supply,erection and testing of Refrigerant Copper pipes of the following diameters to integrate outdoor / indoor units. The liquid line and suction line shall be insulated with closed cell nitrile rubber insulation as specified below. 6.4mm dia liquid pipe with 9mm thick insulation 9.5mm dia liquid pipe with 9mm thick insulation 12.7mm dia liquid pipe with 9mm thick insulation 15.9mm dia liquid pipe with 13mm thick insulation 19.1mm dia gas pipe with 13mm thick insulation 25.4mm dia gas pipe with 13mm thick insulation 28.6mm dia gas pipe with 13mm thick insulation Supply and fixing in position of Heavy duty PVC pipe cut to required length with 13mm thick nitrile rubber insulation, installed with all joints, reducer, necessary elbows and tees. 40 NB 25 NB Supply and laying of 3C x 2.5 Sqmm PVC Copper Cable Control cabling between indoor and outdoor units. The rate shall be including suitable size GI conduit with conduit accessories and necessary fixing arrangement. Supply and laying of 2C x 1.5 Sqmm PVC Copper Cable Control cabling between indoor and outdoor units. The rate shall be including suitable size MS conduit with conduit accessories and necessary fixing arrangement. Nos. 3

596

a b c d e f g 597

RMT RMT RMT RMT RMT RMT RMT

213 128 301 312 28 292 8

a b 598

RMT RMT RMT

103 112 428

599

RMT

239

600

Supply and erection of following sizes Ladder type cable tray made out of 16G thick GI sheet folded to required shape with adequate number of supports for Insulated refrigerant pipe and cable conduits. The tray shall be covered 16G GI sheet at terrace and wherever exposed. 150mm wide 300mm wide 450mm wide PRECISION AIR-CONDITIONING (PAC) SYSTEM Supply, Installation, testing and commissioning of Microprocessor based floor mounted, bottom discharge air cooled precision Packaged air conditioners with ecofriendly refrigerant. Acoustically insulated Indoor unit with DX cooling coil, filter, EC Fan, hermetically sealed scroll compressor, preheater, humidifier, automatic control thermostat and humidistat, canvass connections, fixing/mounting accessories, adjustable and lockable support brackets, hardware rubber pads etc. The outdoor unit shall consists of Air cooled condenser with condenser coil and propeller fans Electro-Mechanical Microprocessor panel, digital display, programmable control & recording unit complete with intelligent 16 digit 2 line alpha numeric display, function keys, cursor keys, free programmable keys, multi color LEDS, inscription fields with integrated battery backup supply at 24 V AC 50 Hz, starter, push buttons, SPP, thermal overload, safety cut-offs, MCBs provision receive zone fire alarm signal and tripping of PACs during the fire. The price shall be inclusive of he sequence controller and necessary hardware for third party BMS integration. RMT RMT RMT 48 40 2

a b c V 601

Unit shall be fitted with high limit humidity sensor / humidistat mounted in the fan outlet and wired to prevent discharge of saturated air from the precision airconditioner. The unit shall be provided with an under water leakage sensor to be installed in the false flooring below the drain pan for floor discharge units. The unit shall be selected to meet the required condition at chennai ambient. Inside condition shall be maintained as 20 1 C DBT & 50 5 % RH Nominal Capacity: 23.0 TR, Air flow rate: 13780 CFM Downward Flow (4w+1s) 602 Supply and erection of 16 Gauge Refrigerant Copper pipes with closed cell nitrile rubber insulation to integrate outdoor / indoor units as per specification. 15.9mm dia liquid line with 19mm thick insulation 22.2mm dia hot gas line with 19mm thick insulation Nos. 5

a b

RMT RMT

435 435

603

Supply and laying of Power cabling 4Corex16sq.mm with Copper armoured cable with PVC insulated, PVC sheathed, cables from the isolator (located nearby the indoor units) to the indoor units. (Vender shall confirm the cable size based on the selected model) Supply and laying of Control cabling 4core x 2.5 Sq.mm between indoor and outdoor units. The rate shall be including suitable size heavy duty PVC conduit with conduit accessories and necessary fixing arrangement. Supply & fixing of sheet metal plenum box fabricated from 22G GI sheet and branch duct with 24G GI sheet connecting unit bottom to server room below false flooring. The size of the plenum and branch duct shall be as per the drawing. Supply and fabrication of suitable angle iron frame work for supporting the indoor units complete with 2 coats of red oxide and enamel paint. Supply and fabrication of suitable steel frame work for supporting all the condensing units as per site condition and provide clear space for air intake / maintenance complete with 2 coats of red oxide and enamel paint. All the steel structure works, necessary civil works & RCC works are in PAC vendor scope. Supply and fixing of Powder coated Heavy duty floor mounted supply air discharge grilles with Volume control damper. Size: 600 x 600mm. Supply and fixing of Extruded Aluminium, powder Coated 0 degree deflection return air ceiling grilles of size 600 x 600mm without Volume control damper Supply and fixing in position of Class B GI pipe (humidifier water line) cut to required length installed with all joints, reducer, necessary elbows and tees, supporting arrangements, etc. 40 NB 25 NB Providing and fixing in position the following Ball valves complete with end flanges / matching flanges, additional supports, fixing accessories etc. The valve shall be thermally insulated with 13mm thick nitrile rubber insulation. 25 NB PRECISION AIR-CONDITIONING (PAC) SYSTEM SUMMARY PIPES AND VALVES Supply, erection, testing and commissioning of chilled water pipes. Pipes will be of MS Class C up to 150mm dia as per IS 1239, 6 mm thick for 200mm and 250mm dia pipes and 8mm thick for above 300mm dia as per IS 3589. Necessary RCC pedestals of size 600 x300x150mm high shall be provided at every 2200mm interval to run the chilled fluid piping above the floor level by ACMV contractor.

RMT

50

604

RMT

450

605

Nos.

606

Nos.

607

Lot

608

Nos.

64

609

Nos.

64

610

a b 611

RMT RMT

55 12

Nos.

VI 612

All other pipe supports will have to be on regular pipe hangers with spring and acceptable isolation in each support. The quoted piping rate shall include for incorporating service flanges on all valves, strainers, service screen/basket strainer on the water line entry to all equipments like chilled water coils and chillers service flanges, descalling Tees, airvent valves, drain valves etc., required to make the circuits fully operational. The temporary service strainers shall be removed and discarded after the first few hours of trial runs. The unit rate for piping shall also include the chemical cleaning and passivation as detailed in the specification. The insulation valves shall be considered as onemetre of the size.M.S angle /Channel also to be insulated. Chilled Water piping with black steel pipes, bends, Tees and fittings, factory made supports as follows 613 a 614 100 NB - MS Class C Supply and erection of FM approved Nitrile rubber as per specification for pipe mentioned below: 65 NB Providing and fixing in position the following bare, GI Class B pipe (make-up and drain) cut to required length and installed with all screw joints, reducer, necessary elbows and tees. 40 NB 25 NB Providing and fixing in position the following Butterfly valves (PN16) complete with matching flanges,locking devices,extended flow control lever,thermal insulation with aluminium clading and fixing accessories etc.. as per specification 65 NB - Lever operated Providing and fixing in position the following Brass Ball valves complete with end flanges/matching flanges, additional supports, fixing accessories etc. as per specification 25 NB - Lever operated Supply and erection of balancing valves, non-rising spindle of stainless steel SS410 stem, stainless steel disc of AISI SS410 with EPDM sealing on seat, double seal by EPDM back flow and graphic asbestos packing on spindle C1220 cast iron / aluminium / MS fabricated hand wheel with pressure test cocks for measurements and regulation of flow through pressure drop across the valves, 50mm thick EPS as thermal insulation with Aluminium cladding as specified, flanges boards, drain valves etc. suitable for computerized balancing instrumentation probes. 65 NB RMT 12

RMT

12

a b 615

RMT RMT

26 45

Nos.

616

Nos.

617

Nos.

618

619

Supply and installation of electronic, Self-balancing, pressure independent type dynamic balancing valve with integrated 2-way modulating control valves in a single body. The actuator shall be capable of accepting 2-10VCD, 4-20mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close of pressure of actuator must be 1.5 times shut off head of pump as per specification of following sizes. 65 NB Supply and installation of 2-way Motorised valves (ON/OFF) with actuator working on 230 V of. If required necessary transformer to be included in the scope 65 NB Supply and installation of MS fabricated Y type strainer with removable brass /stainless steel (SS-316) screen (24G) with 3mm perforation and permanent magnet, drain piping(SS-410) complete with matching flanges and 80mm thick EPS thermal insulation with aluminium cladding as specified 65 NB Supply, installation and commissioning of Water Pressure gauges (bourdan type)complete with ball valve, gauge valve mounting, fittings and copper tubing extension where required Supply and erection of Thermometers of the mercury in glass stem type and copper separable well complete with guard etc. Mounted on water lines, thermowells, drain valves, vent cocks etc., in the inlet and outlet of cooling coil connections. Supply and erection of Automatic Air Vents shall be installed at all high sections of piping. The discharge from this air vents shall be piped via tubes of appropriate size to the nearest waste drain pipe. 1/2'' size AIR DISTRIBUTION SYSTEM Supply, installation, testing and balancing of Air Distribution System consists of factory fabricated sheet metal ducting complete with supports (anchor fastners and tie-rods, cradles, angle iron supports, GI bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, inlets with test openings enclosures complete with locking caps, chain, gaskets, insulating plugs, and extension for insulated ductwork etc. 1.2mm thick GSS (18G) ducting factory fabricated 1.0mm thick GSS (20G) ducting factory fabricated 0.8mm thick GSS (22G) ducting factory fabricated 0.63mm thick GSS(24G) ducting factory fabricated

Nos.

Nos.

620

621

Nos. Nos.

1 4

622

Nos.

623

Nos.

VII 624

a b c d

Sqm. Sqm. Sqm. Sqm.

8 218 401 909

e 625

0.55mm thick GSS (26G) ducting. factory fabricated Supply and installing of Acoustic insulation, Material shall be processed Nitrile Rubber foam. The material should be fibre free. The density of the same shall be within 140-180 Kg/m3.The material should have a thermal conductivity not exceeding 0.050 W/mK. The maximum surface temperature the material should withstand is 105 C and minimum temperature should be 20C. The Thickness of the material shall be 15mm. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7. Supply and erection of Thermal Insulation of Supply air duct with 9mm thick closed cell nitrile rubber temperature range from -10C to +60C, Class O fire category and as per specification. Supply and installation of Thermal Insulation of Exposed supply and return air duct with 25mm thick Pre factory laminated with treated glass cloth of 205 gsm (black colour) nitrile rubber temperature range from -10C to +60C, Class O fire category and as per specification. Supply and installation of Flexible duct connections between main duct and diffuser plenums and main duct to cassette units shall be 25mm thick fiber glass preinsulated, single ply/multiply Aluminium construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminium laminated jackets-Fire resistant complete with Prefabricated and powder coated Aluminium angle frame mounting brackets and supports 100mm dia 200mm dia 300mm dia Supply and fixing of Spigot damper (Butterfly damper) shall be installed from take off collar to diffuser plelum boxes and at plenum boxes (low leakage) made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 100mm dia 200mm dia 300mm dia Supply and fixing of Extruded Aluminium, powder coated Supply air diffusers with removable centre core overall size 600 x 600mm without volume control dampers. 525 x 525mm neck size 450 x 450mm neck size 375 x 375mm neck size 300 x 300mm neck size

Sqm. Sqm.

1771 88

626

Sqm.

653

627

Sqm.

75

628

a b c 629

Rmt Rmt RMT

327 27 10

a b c 630

Nos Nos Nos.

218 18 6

a b c d

Nos Nos. Nos Nos

11 6 20 28

631

a b 632

Supply and fixing of Extruded Aluminium, powder Coated Return air diffusers with removable centre core overall size 600 x 600mm without volume control dampers. 600 x 600mm (outer size) 375 x 375mm neck size Supply and installation of Acoustic insulated plenum boxes for supply air diffusers with 12mm thick, 48 kg/Cu.m density fibre glass rigid board fasten to the plenum box with nuts and bolts. 375 x 375 - 450mm height Supply and installation of Powder coated extruded aluminium continuous linear grilles with 0 degree deflection without volume control damper for fresh air Grille. Supply and installation of Powder coated extruded aluminium continuous linear grilles with 0 degree deflection without volume control damper for exhaust air Grille. Supply and installation of Polypropylene or Aluminium return air round diffuser with white finish. The cone is screwed a number of turns clockwise or anticlockwise so as to achive the air gap. 150mm dia Supply and installation of Polypropylene or Aluminium exhasut air round diffuser (for toilets) with white finish. The cone is screwed a number of turns clockwise or anticlockwise so as to achive the air gap. (Dia150 mm) Supply, installation and commissioning of combined Smoke and Fire damper with actuator complete with factory made 1.6mm thick GSS sleeves suitable for 90 minutes fire rating located in supply air ducts.In case of fire failure the damper shall assume " closed posittion" (suitable for BAS) The motorised actuator to operate the above fire damper on receipt of signal from DDC system /fire detection system. Supply,Installation,Testing and commissioning of following: Actuator,temperature sensor and provision for receipt of external fire signal, wiring as specifications. Supply and installation of Control panel for the above fire damper (to be located near Fire damper in respective AHU/fan rooms Power supply to the fire damper panels shall be provided from AHU/fan electrical panel. These shall be interlocked/integrated with zonal damper status indicating panels. Powder coated extruded aluminium air transfer (non vision) door grilles comprising of front section with inverted V horizontal blades, borders, countersunk for screw fixing, and matching rear side frame flanges.

Nos Nos

32 21

633

Nos Sqm.

24 3

634

Sqm.

635

636

Nos Nos

197 48

637

Sqm.

638

Nos.

639

Nos.

640

Sqm.

641

Supply and installation of GI volume control damper low leakage( wheel type ) made out of 1.6mm thick galvanised sheet steel frame and opposed blades of 1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system. Supply and installation of Non Return damper (low leakage) made out of 1.6mm thick galvanised sheet. Supply, fixing, testing and balancing of Aluminium powder coated Fresh air and exhaust arrangement with storm proof louvers, volume control damper, MS weld mesh bird screen / mounting frame - 100mm louver spacing and 45 deg angle suitable for protection against splashing rain water fixed within a right aluminium frame. Supply and erection of following sizes Ladder type cable tray made out of 16G thick GI sheet folded to required shape with adequate number of supports for Insulated refrigerant pipe and cable conduits. The tray shall be covered 16G GI sheet at terrace and wherever exposed. 150mm wide 300mm wide 450mm wide 600mm wide 900mm wide VENTILATION SYSTEM Supply, installation, testing and commissioning of cabinet type and Rectangular type ventilation fans consists of GSS rectangular cabinet, removable access door for easy accessibility to motor and fan, flanged inlet and outlet for easy duct work connection, thermally protected motor and necessary supports. Motors shall be suitable for 415 +/- 10%v, 50Hz 3Phase & 230 +/- 10%V, 50Hz, 1 Phase AC supply and the capacity are as follows. The fan shall be located at terrace (Weather proof for outdoor type fans and no weather proof for indoor type fans) Air flow rate : 22800CFM (Outdoor type) External Static Pressure : 400 Pa Fan type: Cabinet type fan Indicative Fan motor : 11.0 kW Air flow rate : 14400CFM (Outdoor type) External Static Pressure : 400 Pa Fan type: Cabinet type fan Indicative Fan motor : 7.5 kW Air flow rate : 5550CFM External Static Pressure : 300 Pa Fan type: Cabinet type fan Indicative Fan motor : 2.2 kW Air flow rate : 5550CFM (Outdoor type) External Static Pressure : 300 Pa

Sqm.

10

642 643

Sqm. Sqm.

0.15 49

644

a b c d e VIII 645

RMT RMT RMT RMT RMT

497 717 66 63 19

Nos.

Nos.

Nos.

Nos.

Fan type: Cabinet type fan Indicative Fan motor : 2.2 kW Air flow rate : 3450CFM External Static Pressure : 300 Pa Fan type: Cabinet type fan Indicative Fan motor : 1.5 kW Air flow rate : 2760CFM External Static Pressure : 100 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 1.1 kW Air flow rate : 2550CFM External Static Pressure : 100 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 1.1 kW Air flow rate : 400CFM (Outdoor type) External Static Pressure : 100 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.37 kW Air flow rate : 510 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.37 kW Air flow rate : 500 CFM External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.37 kW Air flow rate : 700 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.37 kW Air flow rate : 978 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.55 kW Air flow rate : 1100 CFM External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.55 kW Air flow rate : 1200 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 0.55 kW Air flow rate : 1400 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 1.1 kW Air flow rate : 1580 CFM (Outdoor type) External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 1.1 kW

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

Nos.

646

Air flow rate : 1800 CFM (Outdoor type) Nos. External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 1.1 kW Air flow rate : 2150 CFM (Outdoor type) Nos. External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor :1.1 kW Air flow rate : 2400 CFM (Outdoor type) Nos. External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor :1.1 kW Air flow rate : 3184 CFM (Outdoor type) Nos. External Static Pressure : 300 Pa Fan type: Rectangular ducted inline fan Indicative Fan motor : 2.2 kW Air flow rate : 4800 CFM Nos. External Static Pressure : 300 Pa Fan type: Cabinet type DIDW Indicative Fan motor :2.2 kW Supply, installation, testing and commissioning of circular inline direct drive fan, wall mounted type complete with gravity louvers, motors, starter panels, powder coated Aluminium angle, mounting brackets, 5amps plug top, 3mtr. flexible power cables, from nearby power outlets, motors shall be included for life ball bearing with internal automatic reset safety thermal overload protection device, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50/60Hz, 1 Phase AC supply. Air flow rate : 350CFM Nos. External Static Pressure : 100 Pa Fan type: Circular ducted inline fan Indicative Fan motor : 0.1 kW Air flow rate : 250CFM Nos. External Static Pressure : 100 Pa Fan type: Circular ducted inline fan Indicative Fan motor : 0.1 kW Supply, installation, testing and commissioning of propeller type direct drive fan, wall mounted type complete with gravity louvers, motors, starter panels, powder coated Aluminium angle, mounting brackets, 5amps plug top, 3mtr. flexible power cables, from nearby power outlets, 600x600x20mm thick marine plywood with hole to suit impeller dia, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50Hz, 1 Phase AC supply. Air flow rate : 2150CFM External Static Pressure : 100 Pa Fan type: Propeller Nos.

647

648

Indicative Fan motor : 1.1 kW Air flow rate : 550CFM Nos. External Static Pressure : 100 Pa Fan type: Propeller Indicative Fan motor : 0.37kW Air flow rate : 250CFM Nos. External Static Pressure : 100 Pa Fan type: Propeller Indicative Fan motor : 0.1 kW Air flow rate : 200CFM Nos. External Static Pressure : 100 Pa Fan type: Propeller Indicative Fan motor : 0.1 kW Air flow rate : 100CFM Nos. External Static Pressure : 100 Pa Fan type: Propeller Indicative Fan motor : 0.1 kW Supply, installation, testing and commissioning of Roof extractor fan type complete with mild steel or galvanised steel mounted on a horizontal square base for cylindical casing, rain hood shall be made of fibre class as protection against adverse weather conditions, impeller shall be manually adjustable pitch blade made of powder coated Aluminium, gravity louvers, motors, starter panels, angle mounting brackets, 5amps plug top, 3mtr. flexible power cables, from nearby power outlets, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50/60Hz, 1 Phase AC supply. Air flow rate : 900CFM External Static Pressure : 100 Pa Fan type: Roof extractor fan (Outdoor type) Indicative Fan motor : 0.37 kW Air flow rate : 700CFM External Static Pressure : 100 Pa Fan type: Roof extractor fan (Outdoor type) Indicative Fan motor : 0.37 kW MS additional supports for hanging all the indoor units ACMV RELATED ELECTRICAL ITEMS Supply,erection,testing and commissioning of starter comprising of the following 1No. 16A TP&N MCB with adjustable variable settings 16 KA with all connected accessories Nos.

66

28

189

Nos.

649 IX 650

kg

2450

651

1 No. DOL (3 Phase) suitable for 2.20KW for exhaust fan with Ammeter, selector switch, suitable ratio of CTs,control fuses, Auto/Manual selector switch, on/off/trip indication lamp with necessary power and control wiring interconnections etc.,with suitable provision to link with IBMS for remote operation and all connected necessary accessories ina suitable MS enclosure with painting , earthling and suitable fixing arrangement as required Supply,erection,testing and commissioning of starter comprising of the following 1No. 63A TP&N MCCB with adjustable variable settings 16 KA with all connected accessories. 1 No. Star Delta starter (3 Phase) suitable for 7.5 KW for cabinet type fan with Ammeter, selector switch, suitable ratio of CTs,control fuses, Auto/Manual selector switch, on/off/trip indication lamp with necessary power and control wiring interconnections etc.,with suitable provision to link with IBMS and all connected necessary accessories in a suitable MS enclosure with painting , earthling and suitable fixing arrangement as required. Supply,erection,testing and commissioning of starter comprising of the following 1No. 32A TP&N MCB with adjustable variable settings 16 KA with all connected accessories 1 No. Star Delta starter (3 Phase) suitable for 7.5 KW for AHU with Ammeter, selector switch, suitable ratio of CTs,control fuses, Auto/Manual selector switch, on/off/trip indication lamp with necessary power and control wiring interconnections etc.,with suitable provision to link with IBMS for remote operation and all connected necessary accessories in a suitable MS enclosure with painting , earthling and suitable fixing arrangement as required Supply,erection,testing and commissioning of starter comprising of the following 1No. 32A TP&N MCB with adjustable variable settings 16 KA with all connected accessories 1 No. DOL starter (3 Phase) suitable for 3.7 KW for HRW with Ammeter, selector switch, suitable ratio of CTs,control fuses, Auto/Manual selector switch, on/off/trip indication lamp with necessary power and control wiring interconnections etc.,with suitable provision to link with IBMS for remote operation and all connected necessary accessories in a suitable MS enclosure with painting , earthling and suitable fixing arrangement as required Supply,erection,testing and commissioning of starter comprising of the following 1No. 63A TP&N MCB with adjustable variable settings 16 KA with all connected accessories.

Nos.

Nos.

652

Nos.

653

Nos.

654

1 No. Star Delta starter (3 Phase) suitable for 11.0 KW for exhaust air fan with Ammeter, selector switch, suitable ratio of CTs,control fuses, Auto/Manual selector switch, on/off/trip indication lamp with necessary power and control wiring interconnections etc.,with suitable provision to link with IBMS and all connected necessary accessories in a suitable MS enclosure with painting , earthling and suitable fixing arrangement as required. CABLE AND TERMINATION Supply, laying of following cables 4 Core 6 Sqmm PVC Cu. Cable 4 Core 4 Sqmm PVC Cu. Cable 3.5 Core 50 Sqmm XLPE Arm.Cu. Cable Supply termination and commissioning of the following size cables with suitable double compression glands and crimping socket with suitable earth clip & fixing accessories. 4 Core 6 Sqmm PVC Cu. Cable 4 Core 4 Sqmm PVC Cu. Cable 3.5 Core 50 Sqmm XLPE Arm.Cu. Cable 3 Core 2.5 Sqmm PVC Cu. Cable Supply and fixing of lockable type push button control for ON / OFF EARTHING Supply, erection of following sizes GI Ladder type cable rack system made out of sheet steel folded to required shape with adequate number of supports. The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc. The metal rack system shall be treated with one coat of rubber based polyvinyl paint as primer and finished with two coats of green enamel paint complete with all civil works for fabrication details

Nos.

655 a b c 656

RMT RMT RMT

45 85 20

a b c d 657

Nos. Nos Nos. Nos Nos

4 10 4 14 313

658

659

150 MM Fire Protection System DIESEL ENGINE DRIVEN PUMP

RMT

160

Supply, installation, testing and commissioning of diesel engine driven pump set as per specification.The engine should have RPM between 1800 to 2100.The Pump shall be horizontal end suction, top discharge mounted on common baseframe. Pump shall be directly coupled to diesel engine of suitable as per system design condition. Engine shall be complete with flywheel, spider coupling, Air cleaners, Water cooled,Heat Exchanger,Corrosion Resistor,Oil Sump with lube at pump. Governor, Fuel Filter,starting motor battery charging alternator & instrument panel suitable for 24 volt DC including starting switches, Diesel tank, lube oil temperature gauge,lube oil pressure & high water temperature including flexible exhaust connection.The pump shall be capable to delivery 171m3/hr. at 120 m head. 129KW approx. 660 MAIN ElECTRICAL DRIVEN FIRE PUMPSET Supply, installation, testing, commissioning of electrically driven pump set as per specification. Motor TEFC type, 2900 rpm, 415V, 50 cycle frequency 3 phase class F insulation, I.P. 54 protection, starting on DOL. The Pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, bronze impeller, steel shaft with common base frame capable of discharging 171 m3 per hour at 120 m head. 110KW approx. JOCKEY PUMPSET Supply, installation, testing and commissioning of electrically driven pump set as per specification. Motor TEFC type, 2900 RPM 415 V, 50 cycles, 3 phase, class F insulation, IP 54 protection, 20 HP(Indicative) starting on DOL. The Pump shall be Vertical Inline Pump. The pump shall have cast iron casing, Cast iron impeller, steel shaft.with common base frame capable of discharging 10.8 m3/hour at 120 m head. MOTOR CONTROL CENTRE (MCC PANEL) Supply installation testing and commissioning of sectionalised cubicle type floor mounted front operated dust and vermin proof power cum control panel made out of not less than 1.6mm MS sheet with enamelled finish i/c. one coat of primer of approved shade and colour i/c. providing suitable number of switchgears, busbars, auxilliary switches, audio alarm hooters, visual indications, relays, contactors, timers of suitable capacity for automatic operation of pumps i/c. connections along with provision to link with IBMS and all connected accessories.Panel should be powder coated, Indicating lamps should be of LED type as per the Single line diagram. Outgoing

Set

Set

661

Set

662

100/125A TP&N MCCB 25 KA with fully automatic DOL Starter suitable for jockey pump with ON/OFF/TRIP indicating lamps,ON/OFF push buttons and all other required accessories -1No 100/125A TP&N MCCB 25 KA with fully automatic star delta starter suitable for booster pump with ON/OFF/TRIP indicating lamps ,ON/OFF push buttons and all other required accessories -3Nos. 400A TP&N MCCB 25 KA with 150 HP fully automatic DOL starter with ON/OFF/TRIP indicating lamps,ON/OFF push buttons and all other required accessories-2Nos. 32A TP&N MCCB 25 KA with all other required accessories with one set of ON/OFF/TRIP indicating lamp with protective fuses-1No With necessary Aluminium busbars,interconnections,earthing etc.,with required accessories as per specifications.

No.

663

DIESEL ENGINE AUTO START PANEL Supply and installation of Autostart panel for the diesel engine complete with auto/manual switch, LED indication lamps, protective fuses with Electronic hooter,Electronic timer,plug in relay,Push buttons ,voltmeter,ammeter,Bridge rectifier,Choke,OFF/AUTO/MANUAL selection switch,TRICKLE/BOOST selection switch,ON/OFF selection switch, battery charger, suitable of working on 230 V, AC, single phase, enclosure being vermin & dust proof. Also potential free contacts shall be provided for connecting to the building automation system. Automatic starting by means of a battery powered electric starter motor incorporating the axial displacement type of pinion, having automatic repeat start facilities initiated by a fall in pressure in the water supply pipe to the sprinkler and/or hydrant installation. The battery (lead acid or Nickel-Cadmium) capacity shall be adequate for ten consecutive starts without recharging with a cold engine under full compression.Panel should be powder coated, Indicating lamps should be of LED type.Panel construction shall be 14SWG M.S sheet bolted/welded..Wiring shall be of 1.5 Sq.mm PVC insulated stranded copper conductor. CABLES: Supply, laying, testing and commissioning of the following sizes of cables on surface of wall or cable traearth clip & fixing Accessories 2 core X1.5Sq.mm PVC copper armoured cable 3 core X1.5Sq.mm PVC copper armoured cable 4 core X1.5Sq.mm PVC copper armoured cable CABLE TERMINATION : Supply terminatin & commissioning of following cables with double compression glands & crimping type Aluminium lugs with suitable earth clip & fixing Accessories 2 core X1.5Sq.mm PVC copper armoured cable

Set

664

a b c 665

RMT RMT RMT

30 30 30

Nos.

b c 666

3 core X1.5Sq.mm PVC copper armoured cable 4 core X1.5Sq.mm PVC copper armoured cable HYDRANT SYSTEM Supply, installation, testing & commissioning of electrically driven pumpset as per specification. Motor TEFC type, 2900 RPM, 415 V 50 cycle, 3 phase Class 'F" insulation, IP - 55 protection, 10 HP starting on DOL. The Pump shall be horizontal, end suction, top discharge. The pump shall be cast iron casing, bronze impeller, steel shaft. with common base frame capable of discharging 27 m3/hour at 45 m head. Pump to be installed at Terrace. Supply and instalation of Cast Iron Sluice Valve, as per IS:14846 with necessary flanges 300 NB, PN.16 200 NB, PN.16 150 NB, PN.16 100NB PN.16 80 NB, PN.16 Supply and installation of Cast Iron Butterfly isolation valve with necessary flanges, supports, bolts, nuts, etc 150 NB 100 NB 65 NB 50 NB Supply, erection, testing and commissioning of gunmetal gate valve with necessary flanges, supports, bolts, nuts, etc & (Below 50NB) screwed ends 50 NB 40NB 20NB Suplying & installation of Cast Iron Non-Return Valves (Normex make) including making flanged joints by providing necessary nuts, bolts, gaskets etc. All complete as per specifications. 200 NB 150 NB 65 NB 50 NB Under Ground piping - Supply, erection, testing and installation of MS pipes conforming to IS 3589 for 200NB & above and IS 1239 for 150NB & below with welded joints including cutting the pipes to correct length, providing and welding flanges to pipe, fixing with clamps to MS brackets/ hangers, making flanged joints with necessary nuts, bolts, gaskets,. blank flanges, etc. Rates including 10% radiograph all complete as per specifications of the following diameters. 200 NB - Class C 150 NB - Class C

Nos. Nos. Nos.

2 6 4

667 a b c d e 668

Nos. Nos. Nos. Nos. No.

2 5 25 2 1

a b c d 669

Nos. Nos. Nos. Nos.

16 4 14 7

a b c 670

Nos. Nos. Nos.

11 49 7

a b c d 671

No. Nos. No. No.

1 16 3 4

a b

RMT RMT

580 1198

c 672

80 NB - Class C Supply, erection, testing and installation of MS pipes conforming to IS 3589 for 200NB & above and IS 1239 for 150NB & below with welded joints including cutting the pipes to correct length, providing and welding flanges to pipe, fixing with clamps to MS brackets/ hangers, making flanged joints with necessary nuts, bolts, gaskets,. blank flanges, etc. Rate shall be inclusive of Zinc chromate primer over that 2 coats red enamel panit as per Fire authorities requirement over all above ground pipes. 400 NB -8mm thick 300 NB -8mm thick 200 NB -6.35mm thick 150 NB - Class C 100 NB - Class C 80 NB - Class C 65 NB - Class C 50 NB - Class C 40 NB - Class C Supply, installation, testing and commissioning of courtyard Gun metal Single headed hydrant as per IS: 5290 consisting of 63NB single outlet flanged oblique type hydrants valve with instantaneous female plunger type coupling, chained blank cap including making flanged joints by providing necessary nuts, bolts, gaskets all complete as per specifications suitable for 80 NB stand post. Supply & installation of RRL type-A hose reel of 63mm dia. x 15metres long with heavy quality gun metal male coupling of IS: 903. combined with 2 Nos of Canvass hoses and 2 Nos of nozzles with ms painted hose tray to accommodate hose reel Supply & installation of fabricated MS sheet of size 750x600x250 with glass fronted door, painted in red out side and white in inside, hose boxes along with GI support angles for courtyard hydrants. Each box shall be capable to accommodate 2 hose each of 63 mm dia x 15 m long hose pipe, nozzle, branch pipe etc. Supply, installation, testing and commissioning of 63mm dia. approved make GM double headed fire hydrant landing valves (with instantaneous female plunger type couplings, chained blank caps) including making flanged joints by providing necessary nuts, bolts, gaskets, etc. painting complete as per specifications. Supply, installation, testing and commissioning of 63mm dia. approved make GM single headed fire hydrant landing valves (with instantaneous female plunger type couplings, chained blank caps) including making flanged joints by providing necessary nuts, bolts, gaskets, etc. painting complete as per specifications.

RMT

37

a b c d e f g h i 673

RMT RMT RMT RMT RMT RMT RMT RMT RMT Nos.

9 4 19 174 178 38 93 73 31 26

674

Nos.

26

675

Nos.

26

676

Nos.

21

677

Nos.

54

678

679

Supply & installation of RRL type-A hose reel of 63mm dia. x 7.5metres long with heavy quality gun metal male coupling of IS: 903. combined with 2 Nos of Canvass hoses and 2 Nos of nozzles with ms painted hose tray to accommodate hose reel Supply & Installation of drum type wall mounting hose reels, swiveling 180o consisting of 25 mm dia. x 30metres long armored rubber hose pipe with 15 mm dia. bronze shut of type jet nozzle & cut-off valve on the inlet including making connection to the wet riser, by drilling welding, fixing the hose reel to the wall by providing necessary anchor fasteners/ expansion bolts, grouting the same with cement mortar, painting all complete as per drawings, specifications. Supply and fixing of fire shutter fabricated out of anodised aluminium sheet and frame,door shall be 900mmx1500mm & fixed with 4mm thick class,suitable rubber beeding and locking arrangement.Rate shall be includes all fateners etc, and complete shutter shall be powder coated of approved colour both inside and outside. Supply & installation of Siamese inlet (Fire Brigade inlet) connection with provision for Four male instantaneous coupling fabricated out of 150 mm dia. approved make heavy class MS pipe with nonreturn valve, for fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications.Connection to Fire Tanks / Yard Hydrants Supply and wrapping of Coating & Wrapping Materials manufactured as per IS 10221 (make:Pypkote) 4mm thick for underground Pipes as per specification Steel pipelines to be laid underground buried in the soil shall be protected against corrosion by means of coating & wrapping as per IS:10221.The above coating and wrapping shall be carried out in systematic manner such that uniform thickness of coating is obtained as per IS specification.Buried pipelines shall be laid in general with top of pipe 1(one) metre below the ground level. Where soil conditions are not satisfactory, masonry or equivalent supports shall be provided at regular intervals. The rate shall be inclusive of holiday test of undergorund pipes.

Nos.

75

Nos.

75

680

Nos.

55

681

Nos.

13

682

Sqm.

965

683 684

Orifice plate made out of stainless steel 5mm thick 80 NB dia Electronic level indicator with pressure transducer sensors ED display high / low level / cabling to pumphouse with indicators etc.,

Nos. Set

26 1

685

686

Supply & installation of 1 No Differential Pressure switch with 1No 150dia dial pressure gauge in 150dia manifold, Bronze check valve with 2mm Orifice, Stainless Steel presssure sensing piping 15mm dia required length as shown in drawing. SPRINKLER SYSTEM Supply, erection, testing and installation of heavy (class C) black steel pipes conforming to IS 1239 with welded joints including cutting the pipes to correct lengths, fixing with clamps to MS brackets / hangers, steel supports, hitec supports as per drawing. The hydro testing shall be done at 18 kgs/cm2 pressure. Rate shall be inclusive of Zinc chromate primer over that 2 coats red enamel panit as per Fire authorities requirement over all above ground pies.Rates to inclusive of all complete as per specifications (including heavy class forged fittings of IS standards) of the following diameters. 150 NB - Heavy Class 100 NB - Heavy Class 80 NB - Heavy Class 65 NB - Heavy Class 50 NB - Heavy Class 40 NB - Heavy Class 32 - Heavy Class 25 - Heavy Class Supply and installation of Cast Iron Butterfly isolation valve with necessary flanges, supports, bolts, nuts, etc 150 NB 100NB 80NB 65NB 50NB Supply, erection, testing and commissioning of gunmetal gate valve with necessary flanges, supports, bolts, nuts, etc. (Below 50NB) screwed ends 50NB 40 NB. 20 NB. Supply & installation of 20 NB CI Automatic Air Release Valve to all Sprinkler risers all complete as per specifications. Supply and installation of Pendant type Sprinkler head with the following temperature rating & respond, universal deflector, chromium finish as per specifications. Size: 15-mm dia. The rate shall be inclusive of Stainless steel Rossette plate in office area and other false ceiling areas. Temperature Rating: 68C Standard respond

Nos.

a b c d e f g h 687

RMT RMT RMT RMT RMT RMT RMT RMT

353 123 385 590 1515 349 849 3642

a b c d e 688

Nos. Nos. Nos. Nos. Nos.

20 4 19 6 4

a b c 689

Nos. Nos. Nos. Nos.

32 16 7 9

690

Nos.

693

691

Supply and installation of Upright Sprinkler head with the following temperature rating & respond, universal deflector, chromium finish as per specifications. Size: 15mm dia. Temperature Rating: 68C Standard respond Supply and installation of Side wall type Sprinkler head with the following temperature rating & respond, universal deflector, chromium finish as per specifications. Size: 15-mm dia. Temperature Rating: 68C Standard respond. Supplying & installing of approved make flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts. 150 NB 100 NB 80 NB 65NB Supply, erection, testing and commissioning of Metallic stainless steel (SS 304) corrugated or braided Flexible drop pipes of 25mm dia with cross bar assembly support suitable for grid ceiling, reducing fitting, special shoulder Nipple, redcing nipple, T bar braket, braket clip assembly. (Make:TYCO / Flex Head / Viking)

Nos.

930

692

Nos.

690

693

a b c d 694

Nos. Nos. Nos. Nos.

7 2 16 3

695

696

697

698

1200 mm Nos. Supply & installation of Instrument cables for flow RMT switches to annunciator panel The cable should be 2 core x 1.5 Sq.mm copper armoured cable. Complete as per specification. Supply & installation of sprinkler annunciator panel Lot consisting of 40 windows, capable of working on 230 V AC single phase supply and provided with battery backup of 24 V complete as per specification. Each windows shall be provided with potential free contact for connecting to the BMS system Supply, installation, testing and commissioning of water No. flow will activate a hydraulic powered water motor alarm by way of integral valve alarm line trim piping. Water motor gong shall be connected to a water pressure retarding chamber to limit the propensity of unnecessary alarms. Water motor alarm shall be equipped with a rear closure plate to limit the access of foreign materials of accumulation of debris.Size of alarm valve shall be 200NB. PORTABLE FIRE EXTINGUISHERS: Supply & installation of following Portable Fire Extinguisher : Carbon Dioxide Fire Extinguisher Nos. Capacity - 4.5 Kg Type - Upright IS - 15683 ABC Fire Extinguisher Nos. Capacity - 5 Kg

683 8833

102

124

699

700

Type - Upright IS - 15683 DCP Type Extinguisher Nos. Capacity - 9 Kg Type - Upright IS - 15683 Supply and installation of Fire buckets of 9 ltrs capacity. Nos. Stand made of MS Channel and angle to accommodate 4 Nos of buckets filled with cleaned soft sand. Rate shall be inclusive of red paint as per Fire Codes for buckets and MS Stand. IBMS works FIRE ALARM SYSTEM. Supply, installation, testing and commissioning of the following system as per the technical specification. Analogue addressable micro Process - controlled Fire Alarm Control Panels, capable of being IP networked to the central monitoring System, to monitor and integrated the following quantity of accessories like detectors, MCP's/hooters/control modules, Fault Isolation Modules, hooters, response indicators, fire/fault indicators, audiovisual signals, central processing units, complete with LCD display, zone indicating LEDs as per the detailed specification: complete with Battery backup with charger for each panel. Each loop should provided with minimum 125 detectors /devices

20

a b c

8 LOOP PANEL 6 LOOP PANEL 1 LOOP PANEL Note: Providing Windows based graphical software, (with necessary software addresses required as per BOQ) on MS windows 2000/XP or latest platform, including Alarm Management for IBMS as per the above item Rate of Rise Heat Detectors (Thermal Detectors):GRADE-I Addressable analogue type Heat Detectors with solid state design with sensing element combination of fixed type and rate of rise of temperature indicating LED, mounting base etc. as per detailed specifications.(wall mounted type) Addressable analogue MUTISENSOR type smoke detectors with dual chamber, solid state design, indicating LED, mounting base etc. as per detailed specification. The rate shall inclusive of necessary base box, connecting glad for above detectors(ceiling, false ceiling, direct ceiling & false flooring mounted type) Duct detector suitable for providing the return air path with suitable fixing accessories Hooter with relay module and strobe light with minimum 85 db audible and control relay module, power supply units etc

No. No. Nos.

1 1 3

701

Nos.

568

702

Nos.

767

703 704

Nos. Nos.

20 96

705

706 707 708 709

710 711

Manual call points pull stations of approved make with NO/NC contacts slim type and projecting out from the surface of enclosure with glass suitable for addressable function Fault isolation module to electrically isolate different sections of detector loops. Addressable control module to trip the AHU,s, Access door, triggering the DVR.lift landing etc Addressable monitor module along with door contact for Fire doors & Beam detector Response indicator for mounting on false ceiling at the entries of the cabin for indicating the operation for detectors in the above areas. 2C 1.5 armoured copper FRLS cable in ceiling with suitable clamps and screws (RED colour) Wall mounted type Beam detector with receiver coverage of minimum 25 mtr distance as per detailed specifications. The adjustable angle shall be +/- 10o for both vertical and Horizontal. The detector should be capable of connecting to existing Addressable fire alarm panel. Wiring to the detectors/devices using 2C x 0.75 sq mm PVC insulated flexible copper conductor (FRLS) in suitable size PVC pipe in concealed system in the floor/ceiling with all accessories like bends,elbows,junction boxes, clamps, GI flexible hose etc., Repeater panel as per the specification (Suitable for above fire panel loop). The rate shall be inclusive of all power supply units, LCD display etc., PUBLIC ADDRESS SYSTEM AND EVC SYSTEM Supply, installation, testing and commissioning of the following system as per the technical specification. System Controller complete with 12 Zone Call Station, Stem Type Microphone, 2 mm thick CRCA Sheet Powder Coated Rack, Dual Tone Control for Speech & Music, integration facility with Fire Alarm System, tone generator & Speech Processor with relays for activating tone & pre-recorded fire alarm messages, facility to integrate with the base builder P.A System as specified in the Tender Specifications . The rate inclusive of Priority module, selector switch etc 42U floor mounted rack frame made out of powder coated materials with ventilation louvers in back side provided with glass door in front side. The rack shall be provided with suitable power sockets/strips, ventilation tray fans, horizontal cable manager, bottom wheel etc 20 W Wall/Column Mounted Speakers with line matching transformers and selected able tap setting as specified in the Tender Specifications

Nos.

108

Nos. Nos. Nos. Nos.

79 24 25 342

RMT set

16000 4

712

RMT

10000

713

No.

II

714

No.

715

No.

716

Nos.

31

717

6 W Wall Mounted Speakers with line matching transformers & selected able tap setting as specified in the Tender Specifications for electrical rooms and AHU rooms 6 W Ceiling Mounted Speakers with line matching transformers & selectable tap setting as specified in the Tender Specifications for false ceiling areas. Rack Mounted minimum 480 W Power Amplifier as specified in the Tender Specifications Rack Mounted minimum 240 W Power Amplifier as specified in the Tender Specifications 2 core twin twisted 48/0.2 ATC, Multi strand, over all armoured speaker cable as specified in the Tender Specifications Micro phone unit with back box, STAND LEGNTH OF CABLES 1 No. each of AM/FM Tuner, DVD player with overriding facility, Music Source Selector, with assignable priority on each channel to accept Music, Telephone, Microphone, Recorded message from Voice recorder etc., with in-built compressor and limiter. Auto dialer for interfacing with Fire alarm system 12 Zone Auto speech processor (Digital Voice Recorder) for fire activation message ACCESS CONTROL SYSTEM Supply, installation, testing and commissioning of the following system as per the technical specification. Access control system complete with necessary hardware, Software etc., as specified for centralized security monitoring. Supply, installation, testing and Commissioning of the following system as per the technical specification. Access Controllers, each with capacity of 10000 events buffer memory connecting the the item listed below such as card readers, Magnetic locks, boom barriers etc 2 reader controller (1 set of single door) 2 reader controller (1 set of double door) 4 reader controller (1 set of single door+1set of double door) 4 reader controller (2 set of Tripod Turnstile) 6 reader controller (3 sets of single door) Smart Card readers with stainless steel base plate Biometric Card readers with stainless steel base plate Electromagnetic Locks - Single Door Electromagnetic Locks - Double Door Magnetic Contact Emergency push button (glass type) FRLS shielded Cables: Cable from electromagnetic lock/Sensor to Controller - 1Sqmm 4 C sqmm multi stand armoued shilelded cable

Nos.

19

718

Nos.

290

719 720 721

Nos. Nos. RMT

3 6 12500

722 723

No. Nos.

1 1

724 725 III

Nos. Nos.

1 1

726

a b c d e f g h i j k 727

Nos. Nos. No. Nos. No. Nos. Nos Nos Nos Nos Nos. RMT

14 9 1 4 1 72 1 18 10 38 28 2650

728 729 730

Cable from Reader to Controller - 1 Sqmm 6 C sqmm multistand shielded armoured cable Network cable for controller to controller Armoured cable Access management software with time and attendance module suitable for flexi time report regeneration as per client requirement with SQL /Oracle data base. Smart Card with holder, Lanyard, Adhesive labels for printing the ID card Visitors management software as per technical specification and system PC comprising Intel core T2 Duo 2.8 Ghz Processor @ L2 Cache 3 MB Intel 31 PR mother board, 2GB DDr2 RAM @ 667 Mhz , 250GB HDD SATA Logitech Keyboard, Logitech Optical mouse, ATX P IV Cabinet with SMPS Prime Source, DVD Writer, Creative 2.1 Speaker with Window NT/2000 operating system. (Main server - HOT Stand by / Parallel reduendancy mode) .The system should be supplied with 21" TFT Color Monitor.- Also, the PC shall be supplied with Web Camera for taking the visitor photos. Boom Barrier 4.5Mtr. Rising Boom Barrier of as per the specification complete with control unit and accessories, for Four wheel vehicle entry. The rate shall includes supply and providing of necessary safety loop coil, pedestal for fixing the Card reader in suitable height with weather proof arrangements. 4.0Mtr. Rising Boom Barrier of as per the specification complete with control unit and accessories, for Four wheel vehicle entry. The rate shall includes supply and providing of necessary safety loop coil, pedestal for fixing the Card reader in suitable height with weather proof arrangements. 3.5Mtr. Rising Boom Barrier of as per the specification complete with control unit and accessories, for Two vehicle entry. The rate shall includes supply and providing of necessary safety loop coil, pedestal for fixing the Card reader in suitable height with weather proof arrangements. 2.5Mtr. Rising Boom Barrier of as per the specification complete with control unit and accessories, for Two vehicle entry. The rate shall includes supply and providing of necessary safety loop coil, pedestal for fixing the Card reader in suitable height with weather proof arrangements. Stainless steel Tripod barriers Tripod Turnstile with stainless steel with electric operated horms (motorized) as per the detailed specification attached Swing gate for Handicap line Full height Turnstile with stainless steel with electric operated horms (motorized) as per the detailed specification attached

RMT RMT No.

6300 2000 1

731 732

Nos. No.

500 1

733

Nos.

734

Nos.

735

Nos.

736

Nos.

737

Nos.

738 739

No. No.

1 1

740 741 742 IV

Booster antenna with pole to activate the RFID tag located at security gate 50mm dia & 1.2 mtr height SS pole for Reader & Egress switch fixing 13.56 MHZ contact less smart Tag with Adhesive back. CLOSED CIRCUIT TELEVISION SYSTEM Supply, installation, testing and commissioning of the following system as per the technical specification. Colour 1/3" fixed dome indoor camera , 540 TV lines resolution and minimum lux level not more than 1.2 lux (F1.2) including all mounting supports / brackets and fixing accessories. Colour 1/3" fixed dome outdoor camera , 540 TV lines resolution and minimum lux level not more than 1.2 lux (F1.2) including all mounting supports / brackets and fixing accessories. Color high speed 1/4" Pan/Tilt/Zoom indoor camera, 540 TVL (PAL)lines resolution and minimum lux level not more than 0.05 lux at F1.2 with 23X optical or better motorized zoom lens, receiver, driver, Pan/Tilt and necessary mounting support / bracket, accessories as required for indoor installation. and mounting support as per specification. Color high speed 1/4" Pan/Tilt/Zoom outdoor camera, 480 TVL (PAL)lines resolution and minimum lux level not more than 0.05 lux at F1.2 with 23X optical or better motorized zoom lens, receiver, driver, Pan/Tilt and necessary mounting support / bracket, accessories as required for outdoor installation along with standard outdoor enclosure with suitable accessories and mounting support as per specification. Power Supply Unit fixed cameras-12V DC/AC Power supply unit as required for the PTZ cameras-24V 16 Channel Duplex Digital Video Recorder for multiplexing and digital recording , suitable for live viewing and playback while recording , Motion detection, alarm event detection with TCP / IP connectivity - Hard disc capacity 4TB Cables: RG 11Coaxial armoured Cable 2 Core 1.5 Sqm Twisted pair Shielded armmoured FRLS cable for PTZ operation 6 Mtr height GI post with necessary mounting bracket, weather proof box and Civil works for external cameras. Mounting bracket with accessories for external camera mounted at terrace .

Nos. Nos. Nos.

36 20 200

743

Nos

12

744

Nos

745

No.

746

Nos

16

747 748 749

Nos Nos Nos

20 17 4

750 751 752

RMT RMT Nos

12600 5000 22

753

Nos

754

755

Excavation of ground to a depth of 3' level and width of 1.5' and refilling etc.for laying the RG 11Coaxial armoured Cable with PTZ operation cable and power cable. Extra earth after re-filling to be leveled in low lying area as directed by the Engineer-in-charge . IP CAMERA Integrated IP Colour 1/3" fixed dome indoor camera , 540 TV lines resolution and minimum lux level not more than 1.2 lux (F1.2) including all mounting supports / brackets and fixing accessories.(Inclusive of POE) Integrated IP Color high speed 1/4" Pan/Tilt/Zoom indoor camera, 540 lines resolution and minimum lux level not more than 0.05 lux at F1.2 with 23X motorized zoom lens, receiver, driver, Pan/Tilt and necessary mounting support / brackets and fixing accessories as per specification. (Inclusive of POE) DVM Dual core Server suitable to connect max. 100 cameras with 5 User License. The rate shall inclusive of necessary software etc (1+1 ) configuration. The rate shall inclusive of necessary storage server, processor server etc., Supply, fixing, testing and commissioning of CAT -12 port switch and patch panel, connected accessories Supply and fixing of Single I/O face plate with RJ 45 connectors with suitable base box 9 U wall mounted rack with socket provision, power chard Video streamer card for connecting the cameras -single camera streamer card. The rate shall inclusive of enclosure box, power supply, filter board, gland etc NOVEC GAS BASED SUPRESSION SYSTEM (SERVER ROOM) Supply, installation, testing and commissioning of the following system as per the technical specification.

RMT

5000

Nos

36

756

No.

757

Nos

758 759 760 761

Nos Nos nos nos

4 80 4 8

762 763 764

120 Ltrs. Cylinder with Valve for Server Room Novec gas Primary Completer Kit complete with Solenoid & Gauge assembly, Discharge Tube, Manual Pneumatic Actuator, Flex Hoses, Warning Sign, Nameplate and Connectors. Slave completer Kit complete with Discharge Tube, Flex Hoses, Pressure Gauge, Elbows and Connectors. Check Valve Nozzles Manifold Rack - Wall Mount Kit M.S. Seamless pipes as per ASTM A 106 Gr. B, schedule 40 with necessary fittings. Gas Release Panel with Battery Backup as Detection & Control equipment as per detailed technical specifications for Gas Suppression system

Nos kgs No.

6 550 1

765 766 767 768 769 770 771

Nos Nos Nos No. Nos No. No.

6 6 14 1 12 1 1

772

773

VI

Manual Release Switch as Detection & Control equipment as per detailed technical specifications for Gas Suppression system Abort Switch as Detection & Control equipment as per detailed technical specifications for Gas Suppression system ASPIRATION SMOKE DETECTION SYSTEM (SERVER ROOM) Supply, installation, testing and commissioning of the following system as per the technical specification.

No.

No.

774

4 zone VESDA panel as per the detailed specification for Aspiration Smoke Detection System - VLS 214 4 Zone Power Supply Unit for the VESDA panel Aspiration Tubes as per the detailed specification for Aspiration Smoke Detection System Capillary Tubes as per the detailed specification for Aspiration Smoke Detection System Air Termination (Nozzles) as per the detailed specification for Aspiration Smoke Detection System Vesda Configuration software as per the detailed specification for Aspiration Smoke Detection System (for both the panel) High Level Interface as per the detailed specification for Aspiration Smoke Detection System (for both the panels) Electronic Hooter for Aspiration Smoke Detection System 2C x 1.5 Sq.mm. Cu. Armoured Cable. Repeater panel to indicate the fault (at BMS room) as per the specification RODENT REPELLENT SYSTEM (SERVER ROOM) Supply, installation, testing and commissioning of the following system as per the technical specification.

No.

775 776 777 778 779

No. RMT Nos Nos No.

1 250 24 24 1

780

No.

781 782 783 VII

No. RMT No.

1 250 1

784 785 786 VIII

VHFO controller with wall mountable stand Satellites with standard cable Suitable cable for the above laid in FRLS PVC conduits WATER LEAK DETECTION ROOM) (conventional type) SYSTEM (SERVER

No. Nos Nos

1 12 150

Supply, installation, testing and commissioning of the following system as per the technical specification. 787 788 789 790 Water Leak detection panel with battery as per specification. Water Leak detection module as per specification. Water leak detection cable sensor (12 mtr) as per specification. Electronic Hooter as per specification. No. Nos Nos No. 1 6 6 1

791 IX

2c x 1.0 Sq.mm copper conductor PVC insulated cable in 25 mm Dia MS Conduit INTERGRATED BUILDING MANAGEMENT SYSTEM AND BUILDING MANAGEMENT SYSTEM: Supply, installation, testing and commissioning of the following system as per the technical specification. BAS SERVER Microprocessor based Integrated Building Management System as per the detailed specifications for complete and satisfactory operation and control and to local authorities approval. Main stations and subsystems with LAN, complete with hardware and software to provide graphical users interface consisting of System PC comprising Intel core i 7 Ghz Processor , 4GB DDr2 RAM @ 667 Mhz , 500 GB HDD , Keyboard, Optical mouse, ATX P IV Cabinet with SMPS Prime Source, DVD Writer, Speaker with Window Latest operating system. The system should be supplied with 21" TFT Color Monitor. .Service pack XP-2 (Main server - HOT Stand by / Parallel redundancy mode) (1 set = 2 nos)

RMT

150

792

No.

793

GRAPHICAL SOFTWARE Providing Windows based graphical software, (with necessary software addresses required as per I/O list) on MS windows 2000/XP or NT platform, including Alarm Management for IBMS as per the above item SOFT POINTS Providing necessary Software and Hardware for Interfacing through a gate way for monitoring through serial Modbus interface for the data points for Chillers , VFDs , VAVs, etc as per the detailed IO summary in HVAC tender . Total soft points 2500 pts including energymetres, UPS etc MONITORING STATION AND PRINTERS: Monitoring station as per technical specification and system PC comprising Intel core T2 Duo 2.8 Ghz Processor @ L2 Cache 3 MB intel 31 PR mother board, 4GB DDr2 RAM @ 667 Mhz , 250GB HDD , Keyboard, Optical mouse, external speakers, sound card ATX P IV Cabinet with SMPS Prime Source, DVD Writer, Service pack XP-2 with Window NT/2000 operating system. The system should be supplied with 21" TFT Color Monitor.-1. FIRE & BMS PC (2-nos) 2. CCTV & ACCESS PC (2-nos) Supply and commissioning of 600 DPI Colour Inkjet Printer Supply and commissioning of Single A4 size Laser Printer DIRECT DIGITAL CONTROLLER:

No.

794

Set

795

Nos

796 797 798

Nos No.

1 1

a b c d e f g h 799 800 a

c d e

Autonomous networkable DDC Controller with 32 bit microprocessor based standalone and networkable type with real time clock and historical database of min 1 Mb with panels, peer to peer communicable DDC modules, input or output relays, terminal block, real time clock, networking and inbuilt data buffer for Following requirement as per Enclosed IO summary . DDC-TYPE A (Chiller) DDC-TYPE B (AHU) DDC-TYPE C (VRV unit) for OFFICE BLOCK DDC-TYPE D FOR REGIONAL STORE DDC-TYPE E FOR FIRE FIGHTING PANEL DDC-TYPE F FOR Bachelors & Transit Accommodation DDC-TYPE G FOR TYPE C&D DDC-TYPE H (Electrical panel at substation) FIELD EQUIPMENT: water level indicator for 3000 mm length For Chiller Immersion type temperature sensor and thermowell across the chiller pipe (Supply header, Return header, Supply header before bypass line and Return header before bypass line) as per the system requirements for BAS system Differential-pressure transducer across the Chiller header (Supply & Return) as per the system requirements for BAS system Flow sensor at chilled water flow as per the system requirements for BAS system Ultrasonicmetre/BTUmetre as per the system requirements for BAS system Pressure transducer across the Chiller header (Supply & Return) as per the system requirements for BAS system For AHU Immersion type temperature sensor in AHU CHW Inlet pipe as per the system requirements for BAS system. Temperature (Supply & Return air) with necessary accessories to monitoring the conditioned area temperature as per the system requirements for BAS system RH Sensors (Supply & Return air) with necessary accessories to monitoring the conditioned area RH as per the system requirements for BAS system Duct static pressure sensor to measure the static pressure in duct as per the AHU I/O listed for BAS system. Differential pressure switch to monitor Filter & Fan status as per AHU I/O listed for BAS system Flowmetre to measure the air flow of AHU at Plenum as per the AHU I/O listed for BAS system For TFA

No. No. No. No. No. No. No. No. Nos. Nos

1 1 1 1 1 1 1 1 2 4

No.

No. No. Nos

1 1 2

801 a

Nos

Nos

Nos

No.

e f 802

Nos No.

3 1

b c d e

Temperature (Exhaust & Fresh air) with necessary accessories to monitoring the conditioned area temperature as per the system requirements for BAS system Differential pressure switch to monitor Filter & Fan status as per TFA I/O listed for BAS system outdoor Temperature sensor Flowmetre to measure the air flow of AHU at Plenum as per the TFA I/O listed for BAS system Immersion type temperature sensor in AHU CHW Inlet pipe as per the system requirements for BAS system. Software for facility management system with nessary hardware accessories CABLES / WIRES FOR IBMS 2 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multi stranded Unscreened cable. [For ON / OFF Command & various status, Supply for Field Devices] 2 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multi stranded, screened cable. [For Sensors] 4 Core 1.0 sq. mm, armoured Annealed Tinned Copper conductor multi stranded, screened cable. [For Sensors] bus cable to intergate all DDCs, BTUmetres, VAVs etc Armoured MISCELLANEOUS ITEMS Supply, installation, testing and commissioning of the following system as per the technical specification. 150 mm wide size slotted angle GI ready made cable trays of 14 SWG GI sheet. The rates for installation shall including necessary anchor fasteners and 'L' angle supports @ 600mm interval etc., to suit site conditions as required all complete as directed by Engineer-Incharge. 300 mm wide size slotted angle GI ready made cable trays of 14 SWG GI sheet. The Quoted rates for installation shall including necessary anchor fasteners and 'L' angle supports @ 600mm interval etc., to suit site conditions as required all complete as directed by Engineer-Incharge. 6 A 3-Pin Socket mounted on PVC Box which has to be fixed in wall as required. The Socket should be of modular type etc all complete as directed by Engineer-Incharge. TOTAL AMOUNT (Rs.

Nos

Nos No. Nos No.

7 1 1 1

803

set

804

RMT

7000

805

RMT

2000

806

RMT

500

807 X

RMT

2800

808

RMT

1750

809

RMT

1000

810

Each

110

Grand Total Rebate Final amount after rebate

nnanagar Western Extension, Chennai - 600 001, Rate Amount

4758 5556 7432

49,573,602 34,502,760 10,256,160

303517 531155 834671

1,517,585 2,655,775 834,671

168 168

1,476,048 34,104

131 131 155 155 181 181

144,100 72,050 85,250 85,250 80,907 199,100

1106 2151 1019 131 204

10,936,128 1,600,344 11,555,460 471,600 1,525,512

160

818,400

4847

2,040,587

5184

1,088,640

5683

4,245,201

8532 8532 8532 8590 8590 8590 8590 8590 8590 8615 8615 8615 8615 8615 8615 8615 8615 8615 8615 8657 8657 8657 8657

37,975,932 3,378,672 827,604 13,116,930 12,696,020 10,806,220 9,680,930 3,676,520 2,559,820 2,567,270 2,567,270 2,567,270 2,567,270 2,567,270 2,567,270 2,584,500 1,766,075 1,679,925 1,679,925 1,688,115 1,714,086 1,056,154 657,932

8657

588,676

3533 3290 1772

2,543,760 1,246,910 3,492,612

77790

227,535,750

532

5,277,440

566 584 584 138

12,852,728 24,970,088 2,130,432 1,539,114

4727

4,282,662

4710 4710 4710 4710 4710 4710 4748 4748 4748 4748 4748 4786 4786 4786 4786 4786 4823 4823 4823 1289

273,180 188,400 155,430 155,430 155,430 164,850 166,180 166,180 166,180 166,180 166,180 167,510 124,436 124,436 124,436 124,436 144,690 62,699 72,345 242,332

1380 1380 1380

2,565,420 1,259,940 1,346,880

1380 1380

897,000 527,160

832 832 832 832 7788

20,800 10,816 37,440 29,120 903,408

727 727 727 727 727 727

53,798 26,899 12,359 12,359 12,359 12,359

749 749 749 749 749 757 757 757 757 757 765 765 765

12,733 12,733 12,733 12,733 12,733 12,869 12,869 12,869 12,869 12,869 17,595 6,885 18,360

1618

3,135,684

1618 1618 1618 1618 1618 1663 1663 1663 1663 1663 1678 1678 1678 1678 1678 1693 1693 1693 1693 1693

2,567,766 1,475,616 1,203,792 1,203,792 1,219,972 1,253,902 1,253,902 1,253,902 1,253,902 1,253,902 1,265,212 1,137,684 817,186 682,946 682,946 858,351 509,593 433,408 443,566 546,839

1017 1017 1017 1017 1017 1017 1062 1062 1062 1062 1062 1077 1077 1077 1077 1077 1092 1092 1092 1092

29,493 291,879 310,185 310,185 310,185 285,777 298,422 298,422 298,422 298,422 298,422 302,637 298,329 298,329 298,329 298,329 366,912 125,580 109,200 3,276

258 193

4,601,946 951,297

122395

31,822,700

105779

4,442,718

108053

3,241,590

100252

6,015,120

4898

352,656

1190

506,940

2099

1,288,786

598

7,011,550

1622

1,523,058

104520

376,272

561 497 829

1,818,201 623,735 644,133

937

669,955

849

983,142

194

5,083,576

378

30,857,652

34

399,194

609

4,285,533

609

392,805

436

3,513,288

436

3,513,288

673

2,756,608

1206

280,998

1206

2,314,314

1206

1,439,964

1357

823,699

1055

2,527,780

3014

7,851,470

3014

7,227,572

7158

5,339,868

641

1,995,433

603

300,294

528 679 829 980 1131 1281 1357 1890 2035 2261 2562 2939 2788 2939 3165 3466 3014 3316 3768 4521 543

5,280 6,790 8,290 9,800 11,310 12,810 13,570 18,900 20,350 22,610 25,620 29,390 27,880 29,390 31,650 34,660 30,140 33,160 37,680 45,210 54,300

22603

678,090 -

7535 11

241,120 330,000

16

16

31 46 76 -

31 46 76

15069 1131

15,069 159,471

15069

587,691

189

9,450

12243 16952 957

122,430 830,648 834,504

905

371,050

1884

2,492,532

24110

1,591,260

14

165,312

1802

6,384,486

2266

5,352,292

5375

6,347,875

7059

12,501,489

955

3,132,400

1002

2,797,584

140

253,120

6996

4,715,304

3901

429,110

4198

155,326

2799

780,921

122885

122,885

22422

3,139,080

874494

874,494

11614

2,218,274

13992

111,936

16791

67,164

6996

13,992

4898

9,796

2799

5,598

13992

2,868,360

1540

303,380

2099

16,792

4478

1,020,984

5247

10,494

6297

138,534

3498

6,996

6297

100,752

10494

20,988

5422

1,453,096

8081

32,324

20988

146,916

11894

95,152

20988

314,820

20988

41,976

13992

27,984

21758

87,032

14762

2,568,588

13992

27,984

16791

33,582

20988

83,952

3498

34,980

1680

307,440

1260

120,960

1400

5,600

630

43,470

630

114,030

1400

33,600

10494 2239

209,880 434,366

1889

217,235

11894

118,940

350

136,150

1085

648,830

1120

24,640

231

131,208

48972

195,888

1141 1540 2344

11,410 30,800 23,440 -

231 259

911,295 1,036

196 224 343 441 714 1260

784 612,640 945,308 563,598 121,380 2,520 -

1120 1400 2729 3848 6017

2,240 1,162,000 185,572 126,984 150,425 -

3673 4128

3,673 8,256 -

5317 4828

5,317 9,656 -

8857 9935

8,857 19,870

840 1295 2099

4,200 9,065 20,990 -

15671 18190 21688

94,026 1,346,060 585,576 -

14692 16091

14,692 32,182 -

3498

76,956 -

13992

41,976

4198

847,996

20988

83,952

140 168

83,440 17,304

490 679 1225

1,132,390 3,288,397 2,156,000 -

280 455 644 1190

183,680 91,000 748,328 935,340

420 595 1120 910

309,540 61,285 1,086,400 577,850

1050 3498

4,200 97,944

224 343 441 714 1260 1610 2239

56,448 137,543 156,555 299,880 432,180 552,230 22,390 -

1330 1924

803,320 706,108 -

1924

1,165,944 -

2099 69,267 -

16791 27984 48972

638,058 531,696 195,888 -

13992

853,512 -

11894 13992

404,396 2,392,632 -

20289

4,159,245

770 1050 1400 1680 2099 20988

47,740 51,450 67,200 15,120 4,198 125,928

1051856

1,051,856 -

191899

959,495 -

104940 209,880 -

349798

349,798

1972776

1,972,776

580916

580,916

10100446

10,100,446

3358056

3,358,056

1403

11,939,530

1259

1,535,980

1465

4,395,000

1244

597,120

2637

3,533,580

8322

2,871,090

3749

2,174,420

5254

966,736

3665

776,980

825

61,050

1991

284,713

2213

2,637,896

3017

241,360

2261

165,053

2433

498,765

5651 5576

2,119,125 11,152

3014

18,084

1281

23,058

1507

678,150

203 193 330

93,380 2,165,460 1,260,600

490

98,000

317

1,287,337

422

373,470

308

30,800

263

526,000

1928

3,092,512

1082

4,251,178

3413

1,433,460

1397

474,980

159

12,043,614

144

7,200

178

13,482,788

189

350,595

362 3222

881,108 7,842,348

283 1087

471,195 1,809,855

1262

2,419,254

4605

12,479,550

3837

1,438,875

654

1,412,640

1330

1,263,500

2907

2,354,670

1199

5,995

3633 3052 3488

18,165 15,260 52,320

4264

2,686,320

3488

3,313,600

8602

10,322,400

6009

60,090

8719 18890

43,595 188,900

1977

796,731

12351

17,908,950

10210 12924

408,400 245,556 -

8644

1,849,816

6441

1,494,312

155732 153877 10514

311,464 1,077,139 1,461,446

1685 1650 982 947

1,090,195 627,000 3,019,650 33,145 -

6600

1,709,400

9164

9,704,676

223

885,310 -

11492 9426

2,930,460 254,502

11822

2,435,332

11767

353,010

17229

482,412

357 357 1678 4376 2056 1408 8505

857,871 429,114 16,780 1,115,880 557,176 5,632 1,794,555

8763

105,156

10524

505,152

22622

2,171,712

7337 745 14035 968 974 239 490 31363

29,348 195,935 2,666,650 968 723,682 10,994 292,530 4,955,354

33686

1,246,382

8170

32,680

3744

14,976

2771 674 2246 250

268,787 359,242 327,916 25,500

869

88,638

31095

357,593

4214

695,310

1962 2616

29,430 1,216,440

1163

1,309,538

1233

573,345

2616

26,160

1956

39,120

16812 12976 11065 3306

50,436 12,976 33,195 310,764

1170

983,970

1452

2,904

7228

433,680

1956

332,520

2180

10,900

197 218 5783

265,950 1,417,000 23,132

9881

29,643

6539

228,865

1109

96,483

2398

990,374

9366

18,732

33143

5,634,310

37215

1,414,170

15986

1,598,600

9695

969,500

13327

79,962

41223

618,345

13513

337,825

74867

224,601

73536 5574

73,536 78,036

74867

224,601

111301

111,301

27451 1236

54,902 24,720

800

16,000

94273 100232

565,638 1,002,320

276228 69683

1,657,368 1,323,977

62010 54174 13350

3,286,530 2,112,786 106,800

49126

1,375,528

68974

137,948

23740

4,391,900

26617

266,170

30927

154,635

34675

69,350

45108

90,216

47686

95,372

77917

5,687,941

26675

106,700

49657

148,971

241120 241120

482,240 241,120

8962

44,810

1608 6813

8,040 34,065

24065

144,390

126560 41180 23950 59025 69158

8,099,840 2,635,520 1,532,800 7,555,200 1,936,424

41798 70981 17657

83,596 851,772 1,165,362 -

126560 41180 23950 59025 17657 54870 86194

506,240 82,360 47,900 236,100 35,314 109,740 172,388

113492

7,490,472

778589

49,829,696

330922

9,265,816

589555

589,555

935149

1,870,298

23901

2,007,684

16761

5,665,218

50849

2,593,299

10645

766,440

4496

107,904

40032 53882

640,512 1,077,640

9852 11537

147,780 80,759

12528

28,814,400

4078

20,390

8206

41,030

8335

941,855

3263

2,251,470

33717

14,329,725

31271

156,355

32086

3,529,460

29640

148,200

60683

788,879

23131 23131

231,310 462,620

23637 23637

118,185 283,644 -

8206

1,395,020

8206

12,596,210

13018

911,260

9723

2,479,365

8695

86,950

5058 7,587,000

5220

30,145,500

816

1,248,480

607

482,565

7748

813,540

8972

89,720

12234 12234

19,574,400 122,340 -

8483 9298 6613

254,490 92,980 66,130

3263

1,288,885

3263

326,300

1034

51,700

10815

216,300

6269

313,450

509736

2,038,944

1391441 7494493

1,391,441 7,494,493

1859847

3,719,694

1261000

1,261,000

1787500

1,787,500

2043682

4,087,364

970

97,000

16060

16,060

11149

66,894

46930

2,815,800

43703

2,884,398

41358

992,592

268195

268,195

32500

32,500

32500

32,500

26000 13000 13000 32500

26,000 13,000 13,000 32,500

13000

13,000 -

6015642

6,015,642

891745

1,783,490

292750

292,750

759268

759,268

276819

276,819

225129

225,129

223829

223,829

189368

189,368

222529

222,529

223829

895,316

223829

2,909,777

241059

482,118

223829

223,829

223829

2,238,290

188068

188,068

126461

505,844

188068

188,068

164823

164,823

400032

400,032

281988

281,988

188068

188,068

300065

300,065 -

301365

301,365

215214

215,214

197984

197,984

80786

161,572

21977 1,208,735

13036

104,288

21519

1,312,659

23872

143,232

27278

1,964,016

62,034

31017

25015

175,105

22660

45,320

37718

113,154

35460

141,840

31,017

31017

32588

97,764

27550

220,400

25015

25,015

22660

67,980

37526

37,526

25,804

25804

5186 191,882

89,716

22429

23754 712,620

59684 2014 917 15513 15513

119,368 4,028 18,340 15,513 93,078 498,834

23754

59749 2079 982 15578

59,749 2,079 13,748 77,890 973,008

27028

67820 2547 1112 15708

67,820 2,547 26,688 219,912 -

31775

3,622,350

100274 3015 1495 63740 50504 28093 21405 15448

401,096 12,060 113,620 63,740 50,504 28,093 449,505 30,896 -

7452

819,720

5322

478,980

1468 785

954,200 667,250

2124

165,672

53

254,400

213

1,001,100

69

20,700

83

240,700

247

518,700

1590

795,000

884 463 133

2,824,380 570,416 1,263,500

69

324,300

166

1,826,000

677

119,152

384

176,640

634

174,350

1664

16,640

384

21,120

302

122,008

463

885,256

1433

117,506

348

87,000

450

79,650

2016

963,648

4919

108,218

4854

43,686

2748

54,960

7092

156,024

17727

159,543

26000

26,000

26000

78,000

20092

100,460

81

810

564

2,256

1299

5,196

81

810

294

119,364

1192

21,456

199 296

14,925 50,024

1104

8,832

191

1,910

302

170,328

1442

50,470

341

64,790

605

330,330

1416

36,816

311

32,655

1130

6,780

372

212,784 -

124 144 195 421 55 64 86 109

12,400 547,200 9,750 21,050 5,500 6,400 60,200 10,900 -

984

334,560

135 1370

18,360 164,400

170 2362

8,160 472,400

251

20,080

705

52,875

108 842

3,240 21,050

139

1,390 -

7042

7,042

1499 2105 3225 3566 4321

89,940 52,625 80,625 142,640 86,420 -

5221 6643 7563 9234 848

26,105 13,286 37,815 9,234 27,136

1152

36,864

9022

36,088

22

121,000

56

84,000

59

147,500

103

154,500

26

182,000

698 59

27,920 147,500

1401 1113 919 618 528 260 205 177 134 277 169 121 893 426 218 159 101 66 602 326 237 207

3,964,830 445,200 827,100 33,990 16,896 702,000 153,750 513,300 509,200 886,400 16,055 955,900 392,920 276,900 196,200 36,570 2,020 21,780 60,200 32,600 11,850 517,500 -

2945 2257

106,020 9,028

1932 1330 1195 980 767 475 465 430 283 273 780 650 390 260 195 130 403 311 294 282 256

50,232 5,320 4,780 56,840 42,952 105,450 113,460 28,380 566 36,036 62,400 13,000 17,160 4,160 780 4,160 1,612 1,244 1,176 22,560 6,912 -

7019

168,456

21230

764,280

277 144 545 99 3497

102,490 50,400 185,300 255,420 524,550 -

1026 1339 722 789 878 1310 3900 1175

410,400 468,650 649,800 39,450 702,400 78,600 273,000 11,750 -

2877

8,631

2175

54,375

234

46,800

368

3,680

4263

42,630

1221 1713

2,442 10,278

300

600

234

1,404

9126 611

91,260 6,110

382 88 2012

64,940 30,800 185,104 -

67339

6,195,188

13000 1,196,000

31884 956,520

27061 270,610

127595

5,358,990

31604

126,416

40433

161,732

32971 329,710

32418 1,037,376

32971

329,710

41846

83,692

55107

330,642

27061

162,366

1177522

2,355,044

263527

527,054

1056752

1,056,752

219822

219,822

545835

1,091,670

352236

352,236

117845

117,845

468781

937,562

166403 499,209

568

255,600

26173

78,519

28672

172,032

547 10

54,700 3,000 37,320

12440

7000000 7,000,000

2227

659,192 939,120 213,256 214,380

1806

1403

1985

4930

2,780,520 127,868 86,160 242,496 16,629

4918

2872

2526

5543

919

9,190 17,480

2185

2882

129,690

919

675

985

6605

552,319 58,050 142,825 99,075

8450

253,500

11700

351,000

3312 82,800 -

4363

436,300

17727

177,270

6157

307,850

2019

1,021,614

1629

107,514

4082

983,762

5616

16,848

187

374,000

133

266,000

6916

221,312

3549

1,249,248

2912

652,288

2548

163,072

5187

663,936

2730

174,720

5278

337,792

6552

209,664

3458

1,217,216

3185

713,440

4004

256,256

5187

663,936

2730

174,720

6500

416,000

8372

33,488

12194

97,552

26390

527,800

8736

270,816

6552

39,312

4004

56,056

2730

21,840

5200

52,000

10400

41,600

2860

148,720

15600

109,200

15600

62,400

18200

72,800

20150

80,600

10400

10,400

12651437

25,302,874

1089998

2,179,996

1109652

2,219,304

6773379

6,773,379

2074355

2,074,355

4375

218,750

33221

132,884

6459

103,344

9043

542,580

33919

67,838

1461

58,440

552

16,560

73051

146,102

21788

43,576

1261 1368

126,100 136,800

2755

5,510

127032

1,524,384

5182450

10,364,900

3889600

7,779,200

2342600

4,685,200

5006736

5,006,736

3808750

3,808,750

2277451 2,277,451 -

26070 403145

234,630 403,145

529458

529,458

219

109,500

1200687

1,200,687 -

1051002

1,051,002 -

74600 73181 66843 65424 63910 60316 59275 67316 60883 60031 58991 77721

820,600 1,683,163 534,744 1,308,480 1,278,200 1,990,428 3,971,425 134,632 974,128 300,155 530,919 310,884

97682 152954

195,364 152,954 -

134008 162414 170833

268,016 487,242 2,391,662 -

586836 893522 1121826 1164122 1208627 1363625 1501818 345947

586,836 1,787,044 1,121,826 1,164,122 1,208,627 1,363,625 4,505,454 345,947

3976 4638 6058 9463

238,560 111,312 333,190 681,336 -

444

310,356

596 826 1058 1138 1355 1561 1694 2109 2227 2323 2449 308

203,832 756,616 378,764 281,086 453,925 92,099 13,552 297,369 35,632 355,419 313,472 539,000

289

309,230

487 308

273,694 183,568 -

387572 294656 253367

387,572 294,656 253,367

131048 75755 66097 52992

262,096 227,265 2,115,104 105,984 -

224053 182114 137967

672,159 364,228 1,103,736 -

639933

1,919,799 -

444 596 826 1058 1138 1561 1694

94,572 75,990 248,626 330,096 31,864 455,812 13,552 -

487 308 439

50,161 34,496 187,892

308

73,612

667 838 1049

32,016 33,520 2,098 -

2003871 10,019,355 -

1300 1501

565,500 652,935

1047

52,350

320

144,000

45233

226,165

15679

78,395

353746

353,746

5829

373,056

5120

327,680

853 647

46,915 7,764 -

3903

19,515 -

2513 30,156 7,728 -

644

853 647

22,178 29,115 -

14322

57,288 -

3903

7,806 -

25323

25,323

109220

109,220 -

32979

32,979 -

20756 3552

20,756 14,208

2580

10,320

1421

1,421 -

1764 1501 1258 1127

13,230 327,218 503,829 1,024,443

960 1981

1,699,680 174,328

581

379,393

1060

79,500

358 435 487

117,066 11,745 4,627 -

465 624 776

101,370 11,232 4,656 -

2652 2652 2652 2652

29,172 15,912 53,040 74,256

2652 2652

84,864 55,692 -

500 8591

12,000 21,478

13624

108,720

1204 1204

237,188 57,792

12775

34,493

14064

84,384

8093

48,558

11223

23,568

10987

109,870

11855 14367

1,778 707,575

621 666 832 1216 1729

308,637 477,522 54,912 76,608 32,851 -

614334

448628

175142

184717

1,228,668 897,256 175,142 184,717 -

132162

68202

68202

35389

35389

35389

40499

40499

45549

45549

45549

47119

132,162 136,404 68,202 35,389 35,389 35,389 80,998 80,998 91,098 45,549 136,647 47,119 -

47119

56685

56685

117664

177902

47,119 56,685 56,685 117,664 711,608 -

24766

21101

24,766 21,101 -

6482

12,964 -

18125

14183

10715

8928

54,375 936,078 300,020 1,687,392 -

56830

48993

219

113,660 97,986 536,550 -

48667

340,669

58814 117,628

58814 58,814

53784 107,568

66673

133,346

706 501 2088

31,770 42,585 41,760 -

632 592 2964 230 9342

2,528 5,920 11,856 3,220 2,924,046 -

1987

317,920 -

911625

911,625

663000

1,326,000

143650

143,650

193375

193,375

193375

193,375

155 188 243

4,650 5,640 7,290 -

66

132

99 133 0

198 798 -

99450 35360 21548 15470 14365 198,900 176,800 538,700 30,940 14,365 -

7293 6188 5525 4420

116,688 24,752 77,350 30,940 -

7735 6630 884

85,085 324,870 6,188 -

66300 39780 13260 11050

66,300 636,480 39,780 44,200 -

4641 2873

2,691,780 3,441,854

1492

55,204 -

13260 8840 4641 2873 1989 1492 1216 995 718 5967

119,340 35,360 88,179 499,902 354,042 56,696 113,088 72,635 22,258 155,142

4973

129,298

6630

172,380

15470

324,870

6078

328,212

19890

1,491,750

13260

994,500

13260

729,300

19890

258,570

398

384,070

1105 11050

28,730 11,050

60775

425,425

2763 1989 1547 1105 939 718 635 475

975,339 244,647 595,595 651,950 1,422,585 250,582 539,115 1,729,950 -

7293 6188 5746 5525 4420

145,860 24,752 109,174 33,150 17,680 -

7735 6630 884 1989

247,520 106,080 6,188 17,901

387

268,191

387

359,910

442

304,980

5525 5525 5525 4420

38,675 11,050 88,400 13,260 -

1768 122

1,207,544 1,077,626

66300

66,300

55250

55,250

6630 676,260 356,252 -

2873

3315

1989

66,300 9,945

638394 566965 275655

638,394 566,965 826,965 -

3429

1,947,672

4016

3,080,272

12484 10452

249,680 1,003,392

4755

513,540

3478 4458 3182 162

274,762 106,992 79,550 55,404

135 73024

2,160,000 292,096

130

1,300,000

135722

135,722

296032

296,032

79180

79,180

2617

81,127

1565

29,735

1132

328,280

35423 19945 120

106,269 119,670 1,500,000

7330 9212

7,330 9,212

32680 50242

32,680 50,242 -

36134 36853 72270 72270 108405 6939 68960 3744 6649 489 1151 187

505,876 331,677 72,270 289,080 108,405 499,608 68,960 67,392 66,490 18,582 32,228 495,550

260 130 99361

1,638,000 260,000 99,361

466 547715

233,000 547,715

289801

1,159,204

278226

556,452

264751

1,323,755

264751

1,059,004

324641

2,272,487

486604 753514

486,604 753,514

59936 27350 1151

2,157,696 547,000 230,200 -

14525

174,300

23826

190,608

119780

119,780

96456

1,543,296

1151 5470 123570

23,020 92,990 494,280

114 128 22168

1,436,400 640,000 487,696

4895

14,685

360

1,800,000

43118

1,552,248

309669

309,669

3026252

3,026,252

79180 1151 17994 2488

316,720 92,080 71,976 19,904

118554 3715 85664

711,324 2,043,250 85,664

36249 30529 4970 67650 17994 146065 54702

217,494 183,174 69,580 67,650 215,928 146,065 54,702

2880

2,880

2880

2,880

685292

685,292

44627 132 2017 2017 132446

44,627 33,000 48,408 48,408 132,446

223137

223,137

3744 130 63341

3,744 32,500 63,341 -

23033 2017 130

23,033 24,204 19,500 -

59010 14109 979 3744

59,010 84,654 5,874 3,744

183

27,450 -

532656

532,656

339754

339,754

1362335

1,362,335

97893

391,572

27350 22168

27,350 22,168 -

94297 157161 157161 31433 31433 31433 31433 282893 18500 3377

94,297 157,161 157,161 31,433 31,433 31,433 31,433 282,893 37,000 13,508

25088

25,088

22315 520449 13261

22,315 520,449 26,522

3377

6,754

7181

21,543

2488

7,464

16740

16,740

3068 38582

9,204 38,582 -

1497

5,988

3068 16645 38582 3377

21,476 16,645 38,582 3,377

8460

8,460 763,000

109

114

228,000

171

85,500

130

364,000

1123

1,965,250

1522

1,522,000

1165

128,150

1,728,888,475

Grand Total 2% Final amount after rebate

1,730,124,013 34,602,480 1,695,521,533