BCM184F - Technical Data Sheet

BCM184F
SPECIFICATIONS & OPTIONS
SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001.

STANDARDS Marine generators may be certified to Lloyds, DnV, Bureau Veritas, ABS, Germanischer-Lloyd or RINA. Other standards and certifications can be considered on request. VOLTAGE REGULATORS AS440 AVR Standard With this self-excited system the main stator provides power, from an auxiliary winding, via the AVR to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-ofphase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access.

The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%.

NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range.

BCM184F
WINDING 71
CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT INSULATION SYSTEM PROTECTION RATED POWER FACTOR STATOR WINDING WINDING PITCH WINDING LEADS STATOR WDG. RESISTANCE ROTOR WDG. RESISTANCE EXCITER STATOR RESISTANCE EXCITER ROTOR RESISTANCE R.F.I. SUPPRESSION WAVEFORM DISTORTION MAXIMUM OVERSPEED BEARING DRIVE END BEARING NON-DRIVE END 1 BEARING WEIGHT COMP. GENERATOR WEIGHT WOUND STATOR WEIGHT WOUND ROTOR WR INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE 151 kg 55 kg 49.74 kg 0.1909 kgm 2 161 kg 84 x 59 x 75 (cm) 50 Hz TELEPHONE INTERFERENCE COOLING AIR VOLTAGE SERIES STAR VOLTAGE PARALLEL STAR VOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS X'd DIR. AXIS TRANSIENT X''d DIR. AXIS SUBTRANSIENT Xq QUAD. AXIS REACTANCE X''q QUAD. AXIS SUBTRANSIENT XL LEAKAGE REACTANCE X2 NEGATIVE SEQUENCE X0 ZERO SEQUENCE T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 380/220 190/110 220/110 22 1.474 0.148 0.096 0.732 0.166 0.059 0.139 0.063 THF<2% 0.095 m/sec 200 cfm 400/231 200/115 230/115 22 1.331 0.134 0.087 0.661 0.150 0.054 0.126 0.057 415/240 208/120 240/120 22 1.236 0.124 0.080 0.614 0.139 0.050 0.117 0.053 440/254 220/127 254/127 N/A N/A N/A N/A N/A N/A N/A N/A N/A 416/240 208/120 240/120 25.4 1.761 0.178 0.112 0.872 0.197 0.071 0.160 0.076 AUXILLIARY WINDING AS440 1.0 % REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CLASS H IP23 0.8 DOUBLE LAYER CONCENTRIC TWO THIRDS 12 0.26 Ohms PER PHASE AT 22C SERIES STAR CONNECTED 0.74 Ohms at 22C 8 Ohms at 22C 0.115 Ohms PER PHASE AT 22C BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min BALL. 6309 - 2RS. (ISO) BALL. 6306 - 2RS. (ISO) 2 BEARING 154 kg 55 kg 50.52 kg 0.1909 kgm 2 164 kg 84 x 59 x 75 (cm) 60 Hz TIF<50 0.119 m/sec 250 cfm 440/254 220/127 254/127 27 1.673 0.169 0.107 0.828 0.187 0.068 0.152 0.072 460/266 230/133 266/133 27 1.531 0.155 0.098 0.758 0.171 0.062 0.139 0.066 480/277 240/138 277/138 27 1.406 0.142 0.090 0.696 0.157 0.057 0.128 0.060

REACTANCES ARE SATURATED

VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.02 s 0.005 s 0.4 s 0.006 s 1/Xd

50 Hz

BCM184F
Winding 71 THREE PHASE EFFICIENCY CURVES

60 Hz

BCM184F
Winding 71 THREE PHASE EFFICIENCY CURVES

BCM184F
Winding 71 Locked Rotor Motor Starting Curve

50
Hz
30
380V 400V 415V

25

20
PER CENT TRANSIENT VOLTAGE DIP

15

10

0 0 10 20 30
LOCKED ROTOR kVA

40

50

60

60
Hz
30
380V 416V 440V 460V 480V

25
PER CENT TRANSIENT VOLTAGE DIP

20

15

10

0 0 10 20 30 40 50 60 70 80 90
LOCKED ROTOR kVA

BCM184F
Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection.

50 Hz

1000

SYMMETRICAL ASYMMETRICAL

CURRENT (Amps)

100

10 0.001

0.01

TIME (secs)

0.1

10

Sustained Short Circuit = 138 Amps

60 Hz

1000

CURRENT (Amps)

100
SYMMETRICAL ASYMMETRICAL

10 0.001

0.01

0.1 TIME (secs)

10

Sustained Short Circuit = 170 Amps


Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : 50Hz
Voltage 380v 400v 415v 440v Factor X 1.00 X 1.07 X 1.12 N/A

Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit :
3-phase 2-phase L-L 1-phase L-N

60Hz
Voltage 416v 440v 460v 480v Factor X 1.00 X 1.07 X 1.12 X 1.18

The sustained current value is constant irrespective of voltage level

Instantaneous x 1.00 x 0.87 x 1.30 Minimum x 1.00 x 1.80 x 3.20 Sustained x 1.00 x 1.50 x 2.50 Max. sustained duration 10 sec. 5 sec. 2 sec. All other times are unchanged Note 3 Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 Series Delta = Curve current value X 1.732

BCM184F
Winding 71 / 0.8 Power Factor RATINGS
Class - Temp Rise Cont. E - 65/50C 380 190 220 400 200 230 16.9 13.5 87.9 15.4 415 208 240 16.9 13.5 87.9 15.4 440 220 254 N/A N/A N/A N/A 380 190 220 17.5 14.0 87.8 15.9 Cont. B - 70/50C 400 200 230 17.5 14.0 87.8 15.9 415 208 240 17.5 14.0 87.9 15.9 440 220 254 N/A N/A N/A N/A 380 190 220 20.0 16.0 87.4 18.3 Cont. F - 90/50C 400 200 230 20.0 16.0 87.6 18.3 415 208 240 20.0 16.0 87.6 18.3 440 220 254 N/A N/A N/A N/A Cont. H - 110/50C 380 190 220 22.0 17.6 86.9 20.3 400 200 230 22.0 17.6 87.2 20.2 415 208 240 22.0 17.6 87.3 20.2 440 220 254 N/A N/A N/A N/A Series Star (V) Parallel Star (V) Series Delta (V)

50
Hz

kVA 16.9 kW 13.5 Efficiency (%) 87.8 kW Input 15.4

60
Hz

Series Star (V) Parallel Star (V) Series Delta (V)

416 208 240

440 220 254 20.8 16.6 87.9 18.9

460 230 266 20.8 16.6 87.9 18.9

480 240 277 20.8 16.6 88.0 18.9

416 208 240 20.3 16.2 87.7 18.5

440 220 254 21.5 17.2 87.8 19.6

460 230 266 21.5 17.2 87.9 19.6

480 240 277 21.5 17.2 88.0 19.5

416 208 240 23.1 18.5 87.4 21.1

440 220 254 24.5 19.6 87.5 22.4

460 230 266 24.5 19.6 87.7 22.3

480 240 277 24.5 19.6 87.8 22.3

416 208 240 25.4 20.3 87.1 23.3

440 220 254 27.0 21.6 87.2 24.8

460 230 266 27.0 21.6 87.4 24.7

480 240 277 27.0 21.6 87.6 24.7

kVA 19.5 kW 15.6 Efficiency (%) 87.8 kW Input 17.8

DIMENSIONS

Barnack Road Stamford Lincolnshire PE9 2NB Tel: 00 44 (0)1780 484000 Fax: 00 44 (0)1780 484100

2006

TD_BCM184F.GB_10.06_04_GB