457x191x67 I-SECTION COLUMN (C5)

400 75 50 150 50 75 457x191x67 I-SECTION COLUMN 100

CL

250
305x102x25 GABLE COLUMN (C4)

100

LEVEL

TOP OF R.C COLS/BASES (-50)

GENERAL NOTES
1. This drawing to be read in conjuction with all relevant Architect's Drawings and Engineer's Drawings 2. Dimensions must not be Scaled or Assumed, After Notification, Discrepancies or Missing Dimensions will be corrected in writing by the Engineer

D
25 50 100 50 25
100

D
30mm THICK 25MPa GROUT

M24 GRADE 350W STEEL HD BOLTS

6/M12 ( ANCHOR BOLTS 16 SETS REQUIRED) Bolt shanks to be degreased and mill scale removed before embedding in concrete

B
30mm THICK 25MPa GROUT Varies 150

305x102x25 STEEL COLUMN (GRADE 350W) 75


100

350 100 LEVEL TOP OF R.C COLS (-50)

100

3. All Elements of the Building to be constructed within the tolerances laid down in SABS 0155 "Accuracy in Building" with the following Clasification:
Foundation Grade II Slabs and Columns Grade II FOUNDATION NOTES

Varies 150

75

150

100

500

100

305

700

150

6 No. M12 HD BOLTS

700

950

500

75

100

Bolt shanks to be degreased and mill scale removed before embedding in concrete

M24 ( ANCHOR BOLTS 750mm LONG WITH 100mm THREAD) 50x50x5mm THICK GRADE 350W STEEL WASSER PLATE

M24 GRADE 350W STEEL HD BOLTS

1. Found below loose top soil horizon in medium dense clayey Gravel or Firm to Stiff Sandy Clay at a Bearing Pressure of 150 KPa 2. Levels shown are Approximate and must be verified on site. All Foundation excavations ate to be approved by the Enginner and cleaned prior to pouring 3. All strip foundation to be 600 x 250 deep U.O.N 4. All Excavations to have 50mm minimum Blinding Layer 5. All cavities to cavity brick walls to be filled with 10MPa Mass Concrete below D.P.C Level

650

500

650

200x350x10mm thick Grade 350W steel plate with 6/16mm holes

6/M12 ( ANCHOR BOLTS 16 SETS REQUIRED)

1150

700 3000

1150

350x500x20mm thick Grade 350W Steel Plate with 6/30mm holes 5

80x80x12mm THICK GRADE 350W STEEL WASSER PLATE

75

100

SECTION A-A
SCALE 1:10

SECTION B-B
SCALE 1:10

HD BOLTS DETAIL
SCALE 1:10

SECTION C-C
SCALE 1:10

SECTION D-D
SCALE 1:10

HD BOLTS DETAIL
SCALE 1:10

CONCRETE NOTES 1. All concrete work is to be done in accordance with SABS 1200G and Project Specification 2. CONCRETE STRENGTHS

9
Item

Element

BASE SCHEDULE
DESC. BASE SIZE No. OFF 1. R.C BASE B1 R.C BASE B2 R.C BASE B3 R.C BASE B4 1500 x 3000 x 700 27 1800 x 1800 x 500 15 1800 x 1800 x 450 13 3000 x 3000 x 600 6

Concr. Strength/ Aggregate Size (Mpa/mm) 10/38 30/19 30/19 30/19 30/19

C
BASE B4 COL. C1 BASE B1 COL. C1 BASE B1 COL. C1 BASE B1 COL. C1

2.

BASE B1 COL. C1

BASE B1 COL. C1

BASE B1 COL. C1

BASE B4 COL. C1

3.

Blinding Foundations Surface Beds Columns Beams

Cover (mm) UON on Schedule 50 40 35 30

Max. Water/ Cement Ratio 0.53 0.53 0.53 0.53

A
UP
450

Isolation Joint (I.S) 10mm Jointex

100mm Thick 20mpa/19mm Concrete Surface Bed

140/90

4.

3. Finish to concrete to be as follows Surface Bed Slab Columns Beams Top Soffit Square Round Powerfloat Rough Smooth Rough Smooth Smooth

Varies

250 Micron DPC layer G5 Material Compacted to 95% Mod Aashto in layers with a maximum thickness of 150mm.
150mm thick 20mpa/19mm concrete surface bed with mesh ref 245

Deviding/partition wall to be built directly on top of surface bed slab

COLUMN SCHEDULE
Item DESC. COLUMN SIZE No. OFF 1. 2. 3. 4. COL. C1 COL. C2 COL. C3 COL. C4 COL. C5 400 x 700 250 x 500 400 x 400 33 15 26

4. Where brickwork is built into concrete structure, shot fire hoop straps onto structure at every 5th brick course 5. Legend: u/s denotes U/S denotes D/D denotes UON denotes COS denotes Underside Upstand Beam Downstand Beam Unless Otherwise Noted Check On Site

BASE B2

BASE B2

BASE B2

BASE B2

150

BASE B2

COL. C2

COL. C3

COL. C3

COL. C3

COL. C2

450

305x102x25 I-SEC. 15 457x191x67 I-SEC. 33

5.

Beam size shown as Width x Depth

700

450 1800

700

6. Loadings
Finishes Partitions Imposed Utilities 2.0 kN/m 2.0 kN/m 2.0 kN/m Office 1.5 kN/m 1.5 kN/m 1.5 kN/m Office Roof 2.0 kN/m 2.0 kN/m 2.0 kN/m

SECTION E-E
SCALE 1:20
190

SECTION F-F
SCALE 1:20 190

7. Test cubes are to be taken every 50m or for each concrete pour (Whichever is the Least) or as required by Engineer 8. All cavities to be brick walls to be filled with 10 MPa mass Concrete below D.P.C Level

BASE B2

BASE B2

BASE B2

BASE B2

BASE B2

COL. C2

COL. C3

COL. C3

COL. C3

COL. C2

150mm thick 20mpa/19mm Concrete Surface Bed


150

10mm JOINTEX

100mm THICK 20MPa/19mm CONCRETE SURFACE BED


100

10mm JOINTEX 150 THiCK CONCRETE SURFACE BED

D F F

VARIES

250 Micron dpc layer G5 Material Compacted to 95% Mod Aashto in layers with a maximum thickness of 150mm. 700x250 Reinforce Concrete Stripfooting Foundation
250

250 Micron DPC Layer G5 material compacted to 95% Mod Aashto in layers with a maximum thickness of 150mm. 600x250 Reinforce Concrete Stripfooting Foundation

150mm selected gravel subbase (G5) compacted to 98% Mod Aashto 150mm selected Gravel Subgrade (G7) Compacted to 95% Mod Aashto Insitu Material Compacted to 90% Mod Aashto

REN

ca

DEVELOPERS
Civil, Structural & Electrical Engineers Architect

BASE B2

COL.C3 BASE B2

COL.C3 BASE B2

COL.C3 BASE B2

COL.C3 BASE B2

COL.C3 BASE B2

COL.C3 BASE B2

BASE B2

COL. C2

COL. C2

250

205

190 600

205

205

190 600

205

UP

SECTION F-F
SCALE 1:20

SECTION G-G
SCALE 1:20

TYPICAL LAYER WORKS UNDER CONCRETE SURFACE BED


SCALE 1:20

Client
BASE B2 BASE B2 COL. C2 COL. C2 COL. C3 COL. C3 COL. C3 COL. C3 COL. C3 COL. C3

10

11

12

13

14

15

16

17

D
BASE B3 BASE B3 BASE B3 BASE B3

D
BASE B3 BASE B3

BASE B1

BASE B1
UP

BASE B1

BASE B1

BASE B1

BASE B1

BASE B1

BASE B1

BASE B4

E1
COL. C1 COL. C1 COL. C1 COL. C1 COL. C1 COL. C1 COL. C1 COL. C1 COL. C1

BASE B2

BASE B2

COL. C2

COL. C2

PROJECT
BASE B2 BASE B2 COL. C2 COL. C2 COL. C3 COL. C3 COL. C3 COL. C3

BASE B3

BASE B3

BASE B3

BASE B3

XANOMA SHOPPING & OFFICE COMPLEX


ON ERVEN 3135, 3136 117 TSOLO MHLONTLO MUNICIPAL AREA EASTERN CAPE
DRAWING TITLE

BASE B2

BASE B2

COL. C2

COL. C2

A H

FOUNDATION LAYOUT, SECTIONS AND DETAILS


A,B,C.../ : BEFORE TENDER 0 Z / : TENDER DRAWING / : AS BUILT 1,2,3...../ : AFTER TENDER /A : BY CLIENT /B : BY ARCHITECT /C : BY MECHANICAL OR ELECTRICAL /D : BY RENCA DEVELOPERS /E : BY OTHER ( )

REVISION BASE B2 BASE B2 COL. C2 COL. C2 COL. C3 COL. C3 COL. C3 COL. C3

No

DESCRIPTION

DATE

BASE B3

BASE B3

BASE B3

BASE B3

COL. C1

UP

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1

COL. C1 Checked Date

dm
BASE B4 BASE B1 BASE B1 BASE B1 BASE B1 BASE B1 BASE B1 BASE B1 R.C BASE BASE B1 B1 BASE B1 BASE B1 BASE B1 BASE B1 BASE B1 BASE B1 BASE B4 Designed

2013-04-24
Date

rn
X
Drawn

2013-04-24
Date

rn
Scale As Shown Drawing Number

2013-04-24 File No. 1304-01 Rev.