PULSAR 4

UNIT CENTRALE UNITE CENTRALE CONTROL PANEL Cod. 053050 ALIM. 3 A

~ 230V RESET

TEST
Pu ls ar 4

Revisione 1.1 Rvision 1.1

INSTALLAZIONE RAPIDA
1- K
Pt1 Pt2 Tempo suonata sirene (2 10 min.) Tempo ritardo ingresso (0 60 sec.)

2+K 3 + LED R

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

K MEC LED B LED A +K K

4 + LED V 5 + LED G 6 GND LED

INIT

+ ALIM GND N.O.

N.C. COM GND OUT 3 OUT 2 OUT 1

4
ALIMENTATORE 14,2V BATTERIA 12V

COLLEGARE I MORSETTI 31, 32, 33, 34, 35 AGLI INSERITORI COME MOSTRATO IN FIGURA.

B D P1

A C

P2 P3 P4 P5 P6

~ 230V RESET
IN G/EXT. IN MAN. + ALIM + ALIM

TEST
AND/OR ABIL

GND + 14,2V

OUT GUASTO

OUT IN. 1

ABIL A

ABIL B

GND

GND

GND

IN. 1

IN. 2

IN. 3

IN. 4

17 18 19 20

COLLEGARE LA RETE E LA TERRA ALLA MORSETTIERA

9 10 11 12 13 14 15 16

F U S E

FUSE 4A

1
P4

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER

COLLEGARE I RIVELATORI : POSITIVO ALIMENTAZIONE AL MORSETTO 4 o 6 NEGATIVO ALIMENTAZIONE AL MORSETTO 1,5 o 9 P3 1 CONTATTO D'ALLARME AL IN1 PER I RIVELATORI RITARDATI P2 A 1 CONTATTO D'ALLARME AL IN2,3,4 PER GLI ALTRI B L'ALTRO CONTATTO D'ALLARME AL MORSETTO 1,5 o 9
P1

6
COLLEGARE LA BATTERIA DOPO AVER ALIMENTATO IL SISTEMA

1 2 3 4 5 6 7

1 COLLEGARE A GND TUTTI GLI INGRESSI NON UTILIZZATI (MORSETTI 2,3,7,8,10,11). COLLEGARE LE SIRENE COME INDICATO DI SEGUITO: ALIMENTAZIONE- NEGATIVO AL MORSETTO 22 PER LA SIRENA ESTERNA POSITIVO AL 21 PER LA SIRENA INTERNA POSITIVO AL 31 COMANDO SIRENA- AL MORSETTO 27 (COM) FARE UN PONTICELLO TRA IL 28 E IL 31 (BLOCCATE A POSITIVO)

DOPO AVER ALIMENTATO IL SISTEMA: LEGGERE LA CHIAVE SULL'INSERITORE IL LED ROSSO LAMPEGGIA UNA VOLTA PER CONFERMARE LA LETTURA.

VERIFICARE I PONTICELLI DI PROGRAMMAZIONE:

8
PER FINIRE FISSARE TUTTI I COPERCHI: CENTRALE, RIVELATORI E SIRENE

3
2

P1- NON INSERITO P4- INSERITO P2- INSERITO P5- NON INSERITO P3- INSERITO P6- INSERITO REGOLARE IL TEMPO DI RITARDO RUOTANDO IL POTENZIOMETRO PT1

5) Descrizione tastiera e segnalazioni luminose

LED A e LED B: indicazione dello stato della ZONA A e della ZONA B rispettivamente. LED acceso: zona attivata. LED Spento: zona disattivata. LED lampeggiante zona disattivata e presenza di una condizione di allarme sulla zona stessa (sistema NON pronto per l'inserimento). IMPORTANTE: Le indicazioni del LED A e LED B sono ripetute dai LED sugli INSERITORI.

LED 1,,LED 4 (ROSSI): Tali LED forniscono le indicazioni relative agli ingressi IN1,,IN4 nella condizione di disattivazione Le indicazioni sono le seguenti: LED spento: ingresso fuori servizio LED acceso: ingresso in servizio LED lampeggiante: memorizzazione della condizione di allarme sull'ingresso stesso. IMPORTANTE: non possibile attivare limpianto con tutti gli ingressi fuori servizio.

TASTI 1,,4 Premendo i TASTI 1,,4 con TASTIERA abilitata si passa alternativamente dalla condizione di servizio a quella di fuori servizio, e viceversa, del corrispondente ingresso. La TASTIERA costituita dai TASTI 1,,4 relativi agli ingressi e dal TASTO RESET. La TASTIERA abilitata nelle seguenti condizioni: - in seguito alla disattivazione di ENTRAMBE le zone la TASTIERA abilitata per 30 sec.; l'abilitazione prolungata di altri 30 sec. ogni volta che viene premuto un TASTO ed indicata da LED TEST acceso; - per tutto il tempo in cui il sistema in condizione di TEST.

LED 230 (VERDE): presenza rete. LED 230 spento: rete assente. LED 230 acceso: rete presente.

~ 230V
LED GUASTO (ROSSO): presenza GUASTO. LED GUASTO spento: GUASTO assente. LED GUASTO acceso: presenza condizione di GUASTO LED GUASTO lampeggiante: GUASTO memorizzato.

TEST
Pulsar 4

RESET

LED MAN. (ROSSO): condizione di MANOMISSIONE. LED MAN. spento: MANOMISSIONE assente. LED MAN. acceso: presenza condizione di MANOMISSIONE LED MAN lampeggiante: MANOMISSIONE memorizzata.

LED TEST (GIALLO): condizione di TEST/TASTIERA abilitata. LED TEST spento: centrale in funzionamento normale e TASTIERA non abilitata. LED TEST acceso: TASTIERA abilitata oppure centrale in TEST.

TASTO RESET Tramite il TASTO RESET, con TASTIERA abilitata, possibile effettuare il reset delle memorizzazioni su LED 1,, LED 4, LED GUASTO, LED MANOMISSIONE. Il TASTO RESET altres utilizzato per il raggiungimento della condizione di TEST nel seguente modo: TASTO RESET premuto una volta = RESET MEMORIE TASTO RESET tenuto premuto = ENTRA IN TEST

PIASTRA LOGICA E PONTICELLI UNIT CENTRALE PULSAR 4


Pt1 Pt2 Tempo suonata sirene (2 10 min.) Tempo ritardo ingresso (0 60 sec.)

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

K MEC LED B LED A +K K + ALIM GND N.O. N.C. COM GND OUT 3 (MANOMISSIONE) OUT 2 (ALLARME ZONA B) OUT 1 (ALLARME ZONA A) GND + 14,2V MANOMISSIONE OUT 4 ALLARME ZONA B ALLARME ZONA A

INIT

B D P1

A C

P2 P3 P4 P5 P6

~ 230V RESET

TEST

17 18 19 20

ALIMENTATORE 14,2V BATTERIA 12V

1
GND

2
IN. 1

3
IN. 2

4
+ ALIM

5
GND

6
+ ALIM

7
IN. 3

8
IN. 4

9 10 11 12 13 14 15 16
IN G/EXT. ABIL A ABIL B OUT RIT. IN/OUT IN. 1 AND/OR ABIL OUT GUASTO IN MAN. GND

FIG. 4

Conduttore di terra

FUSE 4A

F U S E

FUSE 4A

Assemblaggio centrale

Collegamento alimentazione

CARATTERISTICHE TECNICHE
1) Caratteristiche generali. - LIVELLO DI PRESTAZIONE GARANTITO: 1 - GRADO DI PROTEZIONE INVOLUCRO: IP 3X - CONDIZIONI AMBIENTALI DI CORRETTO FUNZIONAMENTO: - temperatura: 5 40 C. - umidit relativa: 95% MAX - AUTOPROTEZIONE CONTENITORE: Anti/apertura. - DIMENSIONI: 33x24x13 cm - PESO: 2 Kg. circa 1a) Gruppo di alimentazione CARATTERISTICHE ALIM. 3 A Tensione di rete Corrente nominale con carico Uscita gruppo di alimentazione Uscita verso apparecchiature esterne Batteria Protezioni 230 V ~ 50 Hz 10% 250 mA MAX 14,2 0,1V 3 A MAX 13,5 0,2V 2,2 A MAX Ricaricabile 12 V nominali - 15 Ah MAX Ingresso rete: Sovratensioni e corto-circuito tramite fusibile da 4A. Collegamento batteria: Inversioni di polarit e sovratensioni tramite fusibile da 6,3A. 18 h MAX a partire dalla tensione di 11 V 12 mesi min. 1b) Piastra logica UNIT CENTRALE CARATTERISTICHE PIASTRA LOGICA UNIT CENTRALE Tensione di funzionamento Tensione nominale di alimentazione assorbimento centrale Ingressi Centrale 9 15 V 12 V 100 mA MAX con rel attratto e led/V pr./rete acceso. - 4 ingressi N.C. - 1 ingresso Manomissione N.C. - 1 ingresso GUASTO N.C. - 1 uscite REL a scambio 5 A MAX. - 3 uscite elettriche open collector 100 mA MAX. - 2 uscite elettriche ABIL. - 1 uscita elettrica AND/OR ABIL. - 1 uscita elettrica GUASTO. - 1 uscita elettrica ritardo ingresso/uscita su ING1.

Uscite Centrale

Tempo di ricarica della batteria vita prevista per la batteria

Uscita alimentazione - 3 uscite 13,5V 0,2 V 0,5 A MAX apparecchiature con protezione fusibile ripristinabile PTC esterne Uscite carica batteria - 1 uscita 14,2 0,1 V apparecchiature esterne 0,2 A MAX

2) Collegamenti alla morsettiera (Fig. 4) MORSETTO 4, 6, 31, (+ ALIM). 1, 5, 9, 22, 26, 30,(GND) 2 3 7 8 IN. 1 IN. 2 IN. 3 IN. 4 DESCRIZIONE Uscite alimentazione 13,5 V. Ogni uscita fornisce MAX 500 mA (protette da fusibile ripristinabile PTC). Collegate insieme forniscono MAX 1,5 A. Negativo comune (massa). Ingressi sezione centrale di tipo N.C. Lingresso IN1 ritardato. Il ritardo ingresso programmabile tramite il potenziometro Pt1 fra 0 (istantaneo) e 60 secondi. Il ritardo uscita automaticamente il doppio del ritardo ingresso. CHIUDERE A GND GLI INGRESSI NON UTILIZZATI Ingresso autoprotezione dispositivi esterni: di tipo N.C. CHIUDERE A GND SE NON UTILIZZATO Ingresso segnalazione di GUASTO dispositivi esterni: di tipo N.C. CHIUDERE (IN BASE ALLA PROGRAMMAZIONE DEL PONTICELLO P6) SE NON UTILIZZATO Uscite per il comando di abilitazione dei rivelatori della zona A e della zona B (programmabili tramite P4). Uscita per il comando AND (due zone attivate e tutti gli ingressi in servizio) oppure OR (solo 1 zona attivata). Di solito utilizzata per il collegamento del comando di blocco del combinatore telefonico. Uscita segnalazione di guasto alimentazione o batteria scarica (sirena esterna oppure centrale). Luscita fornisce un negativo in stato di riposo, che diventa volante (OPEN COLLECTOR) quando manca la rete di alimentazione 230V e la batteria scende sotto gli 11V. Uscita di tipo N.O., fornisce un GND in caso di allarme proveniente dall' ingresso ritardato. ESEMPIO: Alluscita pu essere collegato un buzzer per avvertire che si entrati ad impianto attivato e che dopo il tempo di ritardo entreranno in fuzione le sirene. Uscita carica batteria per le sirene e i combinatori. Non presente in caso di mancanza di alimentazione 230V.

10 IN MAN. 11 IN GUASTO EXT. 12 ABIL A 13 ABIL B 14 AND/OR ABIL 15 OUT GUASTO

16 OUT RIT. IN/OUT IN. 1

21 OUT + 14,2V

Uscite elettrica per la segnalazione di allarme zona A, Allarme zona B e manomissione rispettivamente. 23 OUT 1 (ALLARME A) La temporizzazione programmabile tramite il potenziomentro Pt2 fra 2 e 10 minuti. 24 OUT 2 (ALLARME B) 25 OUT 3 (MANOMISSIONE) 27 COM 28 N.C. (OUT 4) 29 N.O. 32 K 33 + K 34 LED A 35 LED B 36 K MEC Uscita a rel per la segnalazione di allarme zona A, allarme zona B e manomissione. La temporizzazione programmabile tramite il potenziomentro Pt2 fra 2 e 10 minuti. Ingresso linea inseritori e/o tastiere seriali. Tutti gli inseritori e le tastiere devono essere collegati in parallelo.

Ingresso chiave meccanica di tipo N.C. Morsetto chiuso a GND: impianto disattivato - aperto: impianto attivato

3) Programmazione ponticelli PONTICELLO P1: programmazione del funzionamento zone/chiavi (NON INSERITO IN FABBRICA): PONTICELLO P1 NON INSERITO 1 ZONA POSIZIONE A NUMERO CODICI CHIAVE 1 CHIAVE CHIAVE MECCANICA FUNZIONAMENTO funzionamento di IN1IN4 ad 1 zona e attivazione con una chiave digitale. funzionamento di IN1IN4 ad 1 zona e attivazione a chiave meccanica sul morsetto 36 ( K MEC ) come segue: Morsetto (K MEC) chiuso a GND centrale disattivata; Morsetto (K MEC) aperto centrale attivata. POSIZIONE B POSIZIONE C 2 ZONE POSIZIONE D 2 CHIAVI 1 CHIAVE 2 CHIAVI funzionamento di IN1IN2 su zona A, IN3IN4 su zona B e attivazione a passo con una chiave digitale. funzionamento di IN1IN2 su zona A, IN3IN4 su zona B e attivazione con due chiavi digitali come segue: chiave digitale 1: attiva e disattiva la zona A; chiave digitale 2: attiva e disattiva la zona B. funzionamento di IN1IN2 su zona A, IN3IN4 su zona B e attivazione con due chiavi digitali come segue: chiave digitale 1: attiva e disattiva la zona A e la zona B a passo; chiave digitale 2: attiva e disattiva SOLO la zona A.

PONTICELLO P2: programmazione AND/OR ABIL (NON INSERITO IN FABBRICA): P2 inserito P2 non inserito funzione OR sul morsetto 14: fornisce la polarit programmata tramite P4 quando una zona o tutte e due le zone sono attivate. funzione AND sul morsetto 14:fornisce la polarit programmata tramite P4 SOLO quando tutte e due le zone sono attivate.

PONTICELLO P3: autoesclusione ingressi (NON INSERITO IN FABBRICA): P3 inserito P3 non inserito Ad ogni apertura sullingresso corrisponde un allarme in uscita. Autoesclusione dellingresso dopo 3 allarmi. Se un singolo ingresso (dove possono essere collegati anche pi rivelatori) genera 3 allarmi nel periodo di attivazione, questo ingresso, viene automaticamente escluso, fino alla successiva disattivazione e riattivazione della centrale.

PONTICELLO P4: programmazione polarit ABIL (INSERITO IN FABBRICA): P4 inserito P4 non inserito il morsetto fornisce un negativo a centrale disattivata, e un positivo a centrale attivata. il morsetto fornisce un positivo a centrale disattivata, e un negativo a centrale attivata.

PONTICELLO P5: programmazione polarit OUT 1-2-3 (INSERITO IN FABBRICA): P5 inserito P5 non inserito il morsetto fornisce un positivo con uscita a riposo, e un negativo con uscita in allarme. il morsetto fornisce un negativo con uscita a riposo, e un positivo con uscita in allarme.

PONTICELLO P6: programmazione polarit IN GUASTO (INSERITO IN FABBRICA): P6 inserito P6 non inserito al morsetto IN GUASTO deve essere collegata unuscita controllo batteria, della sirena esterna, negativa a riposo. al morsetto IN GUASTO deve essere collegata unuscita controllo batteria, della sirena esterna, positiva a riposo.

4) Programmazione tramite potenziometri: Pt1: programmazione tempo ritardo ingresso (0 60 sec.). Ruotando il potenziometro in senso orario possibile variare il tempo di ritardo ingresso fra istantaneo (0 secondi) e 60 secondi. Il ritardo uscita automaticamente il doppio. Pt2: programmazione tempo suonata sirene (2 10 min.). Ruotando il potenziometro in senso orario possibile variare il tempo di suonata fra 2 e 10 minuti.

IMPORTANTE: Al fine di mantenere il grado di protezione IP 3X dell'involucro secondo le norme CEI 79.2 seconda edizione, i cavi di collegamento dovranno entrare nel fondo SOLAMENTE dalla parte posteriore (posta contro la parete) del fondo stesso. Per il collegamento dei vari dispositivi allU.C. PULSAR 4 si consiglia di utilizzare un cavo schermato (sezione: 0,2 mm minima). Lo schermo dei cavi dovr essere collegato al morsetto GND dellU.C. PULSAR 4 lasciando libero l'altro capo.

6) PROCEDURA Dl INIZIALIZZAZIONE Terminate le operazioni di installazione e di predisposizione sulla piastra logica dell'Unit Centrale, si potr effettuare la procedura di INIZIALIZZAZIONE come indicato nel seguito. 6a) Lettura predisposizioni Il sistema legge le predisposizioni nell'istante in cui la piastra Centrale riceve l'alimentazione. La procedura da seguire la seguente: allacciare la rete all'Unit Centrale e verificare che tutti i LED si accendano per un secondo e poi si spengano (nel caso di operativit a due zone i LED si accenderanno due volte). Allacciare la batteria agli appositi cavetti rispettando la polarit e passare alla fase successiva. Tale fase ha significato diverso a seconda della predisposizione del ponticello P1 e del fatto che si operi con una o due zone; in ogni caso si dovranno effettuare le letture della chiave sull'inseritore secondo le seguenti procedure: Operativit con una zona (ZONA A): Operativit con chiave meccanica con il ponticello P1 in posizione A: - in questo caso il dispositivo esterno dovr essere collegato al morsetto 36 (K MEC) e agir nel seguente modo: - dispositivo chiuso a GND: sistema disattivato; - dispositivo aperto: sistema attivato. In questo caso non possibile operare con 2 zone: sar operativa solamente la zona A. possibile raggiungere la condizione di TEST ed effettuare tutte le operazioni di controllo impianto. Operativit con una sola combinazione chiave con il ponticello P1 non inserito: - lnserire la chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio del LED ROSSO sullinseritore per 1 secondo. Operativit con due zone (ZONA A e ZONA B): Operativit con una sola combinazione chiave con il ponticello P1 in posizione B: - lnserire la chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio contemporaneo del LED A e del LED B sullinseritore per 1 secondo. DUE COMBINAZIONI CHIAVE CON: - Chiave digitale 1: attiva e disattiva la zona A; - Chiave digitale 2: attiva e disattiva la zona B. Il ponticello P1 deve essere in posizione C: - lnserire la prima chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio del LED A sullinseritore per 1 secondo; - lnserire la seconda chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio del LED B sullinseritore per 1 secondo. IMPORTANTE: per poter effettuare il TEST dellimpianto occorre che ENTRAMBE le zone siano disattivate. DUE COMBINAZIONI CHIAVE CON: Chiave digitale 1 (prioritaria): attiva e disattiva la zona A e la zona B; Chiave digitale 2: attiva e disattiva SOLO la zona A. Il ponticello P1 deve essere in posizione D: - lnserire la prima chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio contemporaneo del LED A e del LED B sullinseritore per 1 secondo; - lnserire la seconda chiave digitale nell'inseritore verificando l'esito positivo della lettura indicata dal lampeggio del LED A sullinseritore per 1 secondo. Al termine delle operazioni sopra descritte, indipendentemente dalla procedura adottata, il sistema si trover nella condizione di DISATTIVAZIONE con TASTIERA abilitata. Verificare che il LED TEST sia acceso e quindi (entro 30 sec.): - tenere premuto il TASTO RESET per portare il sistema in condizione di TEST; - verificare che LED A e LED B lampeggino ALTERNATIVAMENTE e tale condizione venga ripetuta da LED A e LED B sull'inseritore (visualizzazione della condizione di TEST). A questo punto, con il sistema in condizione di TEST, si potr passare alla fase successiva. 7) CONTROLLO IMPIANTO Nella condizione di TEST si potr effettuare il controllo dell'impianto: essendo presenti in questa fase le uscite OUT ABIL A (morsetto 12), OUT ABIL B (morsetto 13), AND/ORABIL (morsetto 14), i sensori collegati all'Unit Centrale saranno operativi e si potranno quindi effettuare le operazioni di taratura e controllo. E' presente inoltre l'uscita OUT GUASTO, mentre le uscite OUT 1 (morsetto 23) OUT 2 (morsetto 24) OUT 3 (morsetto 25) OUT 4 (morsetto 2729) sono bloccate. Si ricorda che: - SOLO in TEST, i LED corrispondenti agli ingressi, una volta memorizzato lallarme, della ZONA A lampeggiano in sincronismo con LED A, mentre quelli corrispondenti agli ingressi della zona B lampeggiano in sincronismo con LED B, in modo da visualizzare la suddivisione degli ingressi sulle due zone. - Eventuali allarmi vengono memorizzati e visualizzati tramite il lampeggio del LED corrispondente all'ingresso stesso. Terminate tali operazioni: - richiudere tutti i sensori presenti; - allacciare le sirene e gli eventuali dispositivi di telesegnalazione; applicare il coperchio all'Unit Centrale; - tenere premuto il TASTO RESET per USCIRE dalla condizione di TEST; - verificare che LED A e LED B si spengano;

8) IMPIEGO DELL'UNIT CENTRALE PULSAR 4 Terminata la procedura di INIZIALIZZAZIONE il sistema operativo e nella condizione di DISATTIVAZIONE. Verranno descritte le varie fasi operative di impiego. IMPORTANTE: prima di procedere con le operazioni di attivazione e disattivazione accertarsi di avere chiuso la linea manomissione, microswitch antiapertura e IN. MAN, poich in caso contrario non possibile attivare le zone. In caso di MANOMISSIONE permanente al tentativo di attivazione il LED della zona che si vuole attivare lampeggia. 8a) ATTIVAZIONE e DISATTIVAZIONE del sistema Le operazioni di ATTIVAZIONE e DISATTIVAZIONE del sistema avvengono inserendo la chiave nell'inseritore. Ad ogni inserzione si ha il passaggio da uno stato al successivo e inoltre: - vengono tacitate per 8 sec. le segnalazioni di ALLARME e MANOMISSIONE; - le uscite elettriche OUT ABIL A, OUT ABIL B, OUT AND/OR ABIL sono presenti con un ritardo di 8 sec. rispetto all'attivazione della rispettiva zona. Con la sola ZONA A In questo caso operativo solamente il LED A dell'inseritore; tale LED fornisce le seguenti indicazioni: - LED lampeggiante allinserimento della chiave: sistema non pronto per linserimento e condizione di allarme, o manomissione, su uno degli ingressi (per sapere quale ingresso in allarme bisogna premere il TASTO RESET ed entrare in TEST); - LED acceso: sistema attivato; - LED spento sistema disattivato; - LED lampeggiante ad impianto attivato: allarme memorizzato. Durante il periodo di attivazione dellimpianto stato generato uno o pi cicli di allarme nella zona. Con la ZONA A e ZONA B In questo caso sono operativi il LED A e il LED B dell'inseritore; tali LED forniscono le seguenti indicazioni: - LED lampeggiante allinserimento della chiave: sistema non pronto per linserimento e condizione di allarme, o manomissione, su uno degli ingressi (per sapere quale ingresso in allarme bisogna premere il TASTO RESET ed entrare in TEST); - LED acceso: sistema attivato; - LED spento sistema disattivato; - LED lampeggiante ad impianto attivato: allarme memorizzato. Durante il periodo di attivazione dellimpianto stato generato uno o pi cicli di allarme nella zona. - un LED acceso e l'altro spento: una ZONA attivata; - ENTRAMBI i LED accesi: attivazione di ENTRAMBE le zone. IMPORTANTE La sequenza attivazione/disattivazione delle zone diversa a seconda che si operi con un'unica chiave per entrambe le zone, con chiave prioritaria o con una chiave per la ZONA A e una per la ZONA B: questo a causa della diversa operativit delle chiavi sulle zone stesse. Inoltre, in caso di chiave operativa su due zone, una volta attivata la zona e passati 5 secondi alla successiva inserizione della chiave si avr automaticamente la disattivazione della zona precedentemente attivata. In caso di mancata attivazione di una delle due zone al momento dellattivazione dellimpianto, attendere 5 secondi e disattivare la zona precedentemente attivata in modo tale da poter operare sulla tastiera della centrale. 8b) Indicazioni luminose A seguito della disattivazione di ENTRAMBE le zone, diventano operativi i LED 1,, LED 4. Il LED lampeggiante indica la memorizzazione di un allarme. LED GUASTO e LED MANOMISSIONE memorizzano rispettivamente una condizione di GUASTO e di MANOMISSIONE. 8c) Reset memorizzazioni Il reset delle memorizzazioni avviene premendo, per 1 secondo, il TASTO RESET entro 30 sec. dalla disattivazione di ENTRAMBE le zone. L'abilitazione della TASTIERA indicata dal LED TEST acceso. 8d) TEST La condizione di TEST si raggiunge nel modo seguente: - disattivare ENTRAMBE le zone; - entro 30 sec. tenere premuto il TASTO RESET ; - La condizione di TEST indicata da LED A e LED B in centrale e LED A e LED B sullinseritore, lampeggianti alternativamente; - Verificare inoltre che LED TEST resti acceso. In tale condizione si avr: - LED 1 ,, LED 4 operativi; - segnalazioni di ALLARME e MANOMISSIONE assenti; - uscite elettriche OUT ABIL A, OUT ABIL B, AND/OR ABIL presenti; - uscita elettrica OUT GUASTO operativa (FORNISCE UN POSITIVO). - OUT 1 (morsetto 23) OUT 2 (morsetto 24) OUT 3 (morsetto 25) OUT 4 (morsetto 2729) sono bloccate. WALK-TEST In condizione di TEST i rivelatori sono operativi. Per cui possibile effettuare su di essi il WALK-TEST (prova di funzionamento). L'esito del WALK-TEST memorizzato da LED 1 ., LED 4; il reset avviene premendo il TASTO RESET per 1 secondo. Come uscire dalla condizione di TEST Per uscire dalla condizione di TEST sufficiente tenere premuto il TASTO RESET. La centrale si porta automaticamente in condizione di DISATTIVAZIONE. IMPORTANTE La condizione di TEST pu anche essere utilizzata per la manutenzione del sistema; infatti i contenitori dei vari elementi potranno essere aperti senza avere segnalazione di MANOMISSIONE. 9) SOSTITUZIONE DELLA COMBINAZIONE (COMBINAZIONI) CHIAVE La sostituzione della combinazione (combinazioni) chiave possibile in condizione di TEST nel modo seguente: - disattivare ENTRAMBE le zone; - entro 30 sec. tenere premuto il TASTO RESET; - La condizione di TEST indicata da LED A e LED B in centrale e LED A e LED B sullinseritore, lampeggianti alternativamente; - Verificare inoltre che LED TEST resti acceso. - inserire la vecchia CHIAVE (nel caso di chiave prioritaria inserire quest'ultima) nell'inseritore; - verificare che tutti i LED della centrale si accendano per 1 secondo circa e poi si spengano; - effettuare la lettura della combinazione (combinazioni) chiave con le procedure indicate dal punto (6c);

10) RESET CONFIGURAZIONE E VARIAZIONE PREDISPOSIZIONI Per variare le predisposizioni si dovr operare nel modo seguente: - portare il sistema nella condizione di TEST; - togliere il coperchio dell'Unit Centrale; - variare le predisposizioni; - uscire dal TEST; - premere per alcuni secondi il tasto INIT sulla scheda logica dell'UNIT CENTRALE; - rieffettuare la procedura di INIZIALIZZAZIONE indicata al punto (6). IMPORTANTE Dall'istante in cui si preme il pulsante INIT tutte le segnalazione sulle uscite OUT 1 (morsetto 23) OUT 2 (morsetto 24) OUT 3 (morsetto 25) OUT 4 (morsetto 2729) sono bloccate fino alla lettura della combinazione (combinazioni) chiave.

IN CASO DI DIFFICOLTA' PROBLEMA


LED MANOMISSIONE ACCESO FISSO

SOLUZIONE
- Verificare che il morsetto 10 sia chiuso a GND (se non utilizzato) oppure che non vi siano delle manomissioni aperte sui dispositivi collegati a questa linea. - Verificare la corretta chiusura dell'interruttore antimanomissione della centrale. - Se non utilizzato, chiudere a GND il morsetto 11 e inserire il ponticello P6. - Se il morsetto 11 utilizzato, cambiare la programmazione della polarit tramite il ponticello P6. - Un ingresso (o pi ingressi) in condizione di allarme? Entrare in TEST e verificare tramite i LED 14 di quale ingresso si tratta. Assicurarsi che l'ingresso sia a riposo prima di attivare. - Tutti gli ingressi associati alla zona sono fuori servizio (LED 14 spenti)? Mettere in servizio almeno un ingresso utilizzando i tasti 14. - Il LED di manomissione acceso fisso? Seguire la procedura descritta in precedenza.

LED GUASTO ACCESO FISSO

INSERENDO LA CHIAVE IL LED LAMPEGGIA E LA ZONA NON VIENE INSERITA

SI VUOLE VARIARE LA PROGRAMMAZIONE DEI PONTICELLI (P1P6)

- Programmare i ponticelli come desiderato, premere il tasto INIT fino a che non si accendono tutti i LED e procedere nuovamente con la memorizzazione delle chiavi.

D P1

P1 A B

GND

10

ABIL1

18
BATT.

IN2

52

MICRO SWITCH

IN1

51

LAMP.

1 2 3 4 5 6 7

+ 14 V

29

TAMPER TAMPER C/SIR + C/SIR C/BATT GND + 14,2 V

GND

10

29 10 17 15

10
1
A

SCHEMA ELETTRICO U.C. PULSAR 4 CON FUNZIONAMENTO A 1 ZONA


GND
Pt1
C

Tempo ritardo ingresso (0 60 sec.)

2 3
P2 P3 P4 P5 P6

IN. 1 IN. 2
Pt2

ZONA A = IN 1 + IN 2 + IN 3 + IN 4
~ 230V
4
+ ALIM

INIT

RESET

CENTRALE PULSAR 4 PROGRAMMAZIONE:

GND

Tempo suonata sirene (2 10 min.)

6 7
IN. 3

+ ALIM

1- K 2+K 3 + LED R 4 + LED V 5 + LED G 6 GND LED

P1 = OFF P2 = ON P3 = OFF P4 = ON
IN. 4 GND IN MAN.

P5 = ON P6 = ON
IN G/EXT.

ATTIVAZIONE DELLA ZONA CON CHIAVE DIGITALE FUNZIONE "OR" SU MORSETTO 14 AUTOESCLUSIONE DELL'INGRESSO DOPO 3 ALLARMI IMPIANTO ATTIVATO: MORSETTI 12, 13, 14 A POSITIVO IMPIANTO DISATTIVATO: MORSETTI 12, 13, 14 A NEGATIVO USCITA OUT1, OUT2 E OUT3 POSITIVE A RIPOSO IN GUASTO PROGRAMMATO PER SIRENE CON USCITA (C/BATT) DI TIPO N.C. A NEGATIVO

OFF= NON INSERITO ON = INSERITO

ABIL A

TEST

ABIL B

SIRENA ECHO 3: PROGRAMMAZIONE


OUT GUASTO
COM K MEC OUT 1 OUT 2 OUT 3 LED A LED B GND GND GND N.C. + 14,2V + ALIM N.O.

9 10 11 12 13 14 15 16
AND/OR ABIL OUT RIT. IN. 1
+K K

IN 4
P4

P1 = POS. A -C/SIR CONNESSO A POSITIVO: SIRENA BLOCCATA; -C/SIR CONNESSO A NEGATIVO OPPURE APERTO: SIRENA IN FUNZIONE.
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

1 2 3 4 5 6 7

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

TAMPER TAMPER C/SIR GND + ALIM

IN 3
P4

1 2 3 4 5 6 7

COMBINATORE TELEFONICO REPORTER 2000: MESSAGGIO 1 =ALLARME e MANOMISSIONE MESSAGGIO 2 = BATTERIA SCARICA

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

TEL.

TEL.

IN 2
P4

LINEA

1 2 3 4 5 6 7

LINEA

BATT

39

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

+ BATT

10

IR POLARIS: PROGRAMMAZIONE

TAMPER

TAMPER

P1 = ON (LED ATTIVATO) P2 = POS. A (RIV. BLOCCATO A GND) P3 = ON (CONTEGGIO PER 2) P4 = ON PORTATA 16 METRI

OUT TLC

41

IN 1
+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER
P4 P1 B

P2 A

P3

INSTALLATION RAPIDE
1- K
Pt1 Pt2 Dure sonnerie sirnes (2 10 min.) Retard dentre (0 60 sec.)

2+K 3 + LED R

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

K MEC LED B LED A +K K

4 + LED V 5 + LED G 6 GND LED

INIT

+ ALIM GND N.O.

N.C. COM GND OUT 3 OUT 2 OUT 1

4
CHARGEUR 14,2V BATTERIE 12V

RELIER LES NORNES 31, 32, 33, 34, 35 AUX LECTEURS OU AUX CLAVIERS COMME INDIQUE CI-DESSUS.

B D P1

A C

P2 P3 P4 P5 P6

~ 230V RESET
IN PANNE

TEST
AND/OR ABIL

GND + 14,2V

PREALARME

OUT PANNE

ZONE 1

ZONE 2

ZONE 3

ZONE 4

+ ALIM

+ ALIM

ABIL A

ABIL B

IN A/P

GND

GND

GND

17 18 19 20

RELIER LE 220V ET LA TERRE AU BORNIER

9 10 11 12 13 14 15 16

F U S E

FUSE 4A

1
P4

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER

RACCORDEMENT DES DETECTEURS : POSITIF ALIMENTATION AUX BORNES 4 ou 6 NEGATIF ALIMENTATION A LUNE DES BORNES 1,5 ou 9 P3 1 CONTACT D'ALARME A LA ZONE 1 POUR DETECTEURS RETARDES P2 A 1 CONTACT D'ALARME AUX ZONES 2,3 ou 4 POUR LES AUTRES B LAUTRE CONTACT DALARME A LUNE DES BORNES 1,5 o 9
P1

6
RELIER LA BATTERIE APRES AVOIR ALIMENTE LE SYSTEME

1 2 3 4 5 6 7

RELIER A GND TOUTES LES ZONES NON UTILISEES (BORNES 2,3,7,8,10,11).

RELIER LES SIRENES COMME SUIT : ALIMENTATION - POSITIF A LA BORNE 21 SIRENE EXTERNE - POSITIF A LA BORNE 31 SIRENE INTERNE - NEGATIF A LA BORNE 22 COMMANDE SIRENE A LA BORNE 27 (COM)

LIRE LA CLEF SUR LE LECTEUR OU SAISIR LE CODE SUR LE CLAVIER: LA LED ROUGE CLIGNOTE UNE FOIS POUR CONFIRMER LA LECTURE

VERIFIER LES CAVALIERS DE PROGRAMMATION :

P1- ENLEVE P2- EN PLACE P3- EN PLACE

P4- EN PLACE P5- ENLEVE P6- EN PLACE

REGLER LE RETARD DENTREE EN TOURNANT LE POTENTIOMETRE PT1

POUR TERMINER REFERMER TOUS LES BOITIERS : CENTRALE, DETECTEURS, SIRENES ...
11

5) DESCRIPTION FACADE CENTRALE

LED A et LED B: indication de ltat du BLOC A et du BLOC B LED allum : BLOC EN SERVICE LED teint : BLOC A LARRET LED clignotant BLOC A LARRET et prsence dun dfaut de ZONE (le systme ne peut tre mis en service) IMPORTANT : Les mmes indications sont disponibles sur les LED des LECTEURS ou des CLAVIERS BUS.

LED 1,,LED 4 (ROUGES): ces LED fournissent les indications relatives aux zones ZONE 1,, ZONE 4 lorsque la centrale est larrt. Les indications sont les suivantes : LED teinte : ZONE HORS SERVICE LED allume : ZONE EN SERVICE LED clignotante : ALARME MEMORISEE SUR CETTE ZONE IMPORTANT : on ne peut pas mettre en service lorsque toutes les zones sont larrt.

TOUCHES DE COMMUTATION DES ZONES (de 1 4) Les touches de 1 4 permettent de commuter en et hors service les ZONES et la touche RESET permet deffacer les mmoires dalarme. Ces TOUCHES ne sont actives que dans les conditions suivantes : - pendant 30 secondes lorsque lon a mis hors services les deux blocs avec prolongation de 30 ds quune touche est utilise. La LED TEST reste allume pendant toute la priode dhabilitation des touches. - pendant toute la dure de la condition de TEST.

LED 230 (VERTE): prsence SECTEUR 220V. LED 230 teinte : SECTEUR ABSENT LED 230 allum : SECTEUR PRESENT

~ 230V
LED PANNE (ROUGE): prsence dune PANNE LED PANNE teinte : PANNE absente LED PANNE allume :PANNE prsente LED PANNE clignotante : PANNE mmorise

TEST
Pulsar 4

RESET

LED A/P (ROUGE): condition dAUTOPROTECTION. LED A/P teinte: pas dAUTOPROTECTION LED A/P. allume :AUTOPROTECTION prsente LED A/P clignotante: AUTOPROTECTION MEMORISEE

LED TEST (JAUNE) : condition de TEST/TOUCHES EN SERVICE. LED TEST teinte : la centrale nest pas en TEST et TOUCHES non actives LED TEST allume : centrale en TEST ou TOUCHES EN SERVICE

TOUCHE RESET Grce cette touche on peut effacer les mmoires dalarme relatives aux voyants : LED 1,, LED 4, LED PANNE, LED AUTOPROTECTION. La TOUCHE RESET est galement utilise pour passer en TEST de la faon suivante : TOUCHE RESET appuye pendant 1 seconde = EFFACEMENT MEMOIRE TOUCHE RESET maintenue appuye = FONCTION TEST

12

PLATINE ET PONTETS CENTRALE PULSAR 4


Pt1 Pt2 Dure sonnerie sirnes (2 10 min.) Retard dentre (0 60 sec.)

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

K MEC LED B LED A +K K + ALIM GND N.O. N.F. COM GND OUT 3 (AUTOPROTECTION) OUT 2 (ALARME BLOC B) OUT 1 (ALARME BLOC A) GND + 14,2V OUT 4
AUTOPROTECTION ALARME BLOC B ALARME BLOC A

INIT

B D P1

A C

P2 P3 P4 P5 P6

~ 230V RESET

TEST

17 18 19 20

CHARGEUR 14,2V BATTERIE 12V

1
GND

2
ZONE 1

3
ZONE 2

4
+ ALIM

5
GND

6
+ ALIM

7
ZONE 3

8
ZONE 4

9 10 11 12 13 14 15 16
IN A/P IN PANNE OUT PREALARME AND/OR MARCHE OUT PANNE MARCHE A MARCHE B GND

FIG. 4

Branchement terre

FUSE 4A

F U S E

FUSE 4A

Assemblage centrale

Raccordement alimentation

13

CARACTERISTIQUES TECHNIQUES
1) Caractristiques gnrales : - DEGRE PROTECTION ENVELOPPE: IP 3X - CONDITIONS AMBIENTALES DE FONCTIONNEMENT : - temprature: 5 40 C. - humidit relative: 95% MAX - AUTOPROTECTION BOITIER: louverture. - DIMENSIONS: 33x24x13 cm - POIDS: 2 Kg. environ 1a) CHARGEUR CARACTERISTIQUE ALIM. 3 A Tension secteur Courant normal en charge Sortie chargeur Sortie alimentation Batterie Protections 230 V ~ 50 Hz 10% 250 mA MAX 14,2 0,1V 3 A MAX 13,5 0,2V 2,2 A MAX Rechargable 12 V nom. - 15 Ah MAX Entre 220V: surtensions et court-circuit par fusible de 4A. Raccordement batterie : Inversions de polarit et surtensions fusibile de 6,3A. 18 h MAX partir de 11 V 12 mois min. 1b) PLATINE CENTRALE CARACTERISTIQUES PLATINE CENTRALE Tension de fonctionnement Tension nominale dalimentation Consommation centrale Entres centrale 9 15 V 12 V 100 mA MAX avec relais au travail et LED allumes - 4 entres ALARME N.F. - 1 entre AUTOPROTECTION N.F. - 1 entre PANNE N.F. - 1 sortie RELAIS 5 A MAX. - 3 sorties OPEN COLLECTOR 100 mA MAX. - 2 sorties lectriques HABIL. - 1 sortie lectrique AND/OR HABIL. - 1 sortie lectrique PANNE. - 1 sortie lectrique RETARD ZONE 1

Sorties Centrale

Sortie alimentation

- 3 sorties 13,5V 0,2 V avec protection par PTC - 1 sortie 14,2 0,1 V

0,5 A MAX

Temps de recharge de la batterie Dure de vie de la batterie

Sortie charge batterie

0,2 A MAX

2) Raccordements au bornier (Fig. 4) BORNE 4, 6, 31, OUT ALIM. 1, 5, 9, 22, 26, 30,(GND) 2 3 7 8 ZONE 1 ZONE 2 ZONE 3 ZONE 4 DESCRIPTION Alimentation vers dispositifs externes 13,5 V Ngatif commun (masse) ZONES de type N.F. ZONE 1 est retarde. Le retard dentre est programmable par le potentiomtre Pt1 de 0 (instantane) 60 secondes. Le retard de sortie est automatiquement le double du retard dentre. FERMER SUR GND LES ZONES NON UTILISEES Entre AUTOPROTECTION : de type N.F. FERMER SUR GND SI NON UTILISEE Entre signalisation PANNE dispositifs externes: de type N.F. FERMER (EN FONCTION DU PONTET P6) SI NON UTILISEE Sorties TEMOIN MISE EN MARCHE BLOCS A ET B (programmables). Changent de polarit selon la MARCHE ou lARRET des blocs. Servent asservir un transmetteur ou grer la mmoire des dtecteurs. Sortie TEMOIN MISE EN MARCHE PROGRAMMABLE (BLOC A ET BLOC B / BLOC A OU BLOC B). Cette sortie change de polarit selon la Marche ou larrt des deux blocs ou encore de lun dentre eux. Sortie signalisation PANNE dun dispositif externe (sirne externe ou transmetteur). La sortie donne un ngatif au repos et un + ALIM lorsque le 220V disparat et que la batterie est dcharge moins de 11V. Sortie de PRE-ALARME. il est possible de relier un buzzer pour avertir que le retard dentre est en cours et quil faut mettre hors-service la centrale pour viter lalarme. Cette sortie est de type N.O. qui donne un GND en MARCHE EN CAS DE DETECTION. Sortie de charge batterie pour dispositifs tels que sirnes et transmetteurs Cette sortie est inactive lorsque le secteur (220V) est absent 500 mA MAX par sortie (!,5A total) avec fusible PTC

10 AUTOPROTECTION 11 PANNE EXT. 12 MARCHE A 13 MARCHE B 14 ET/OU MARCHE 15 OUT PANNE

16 PREALARME ZONE 1

21 OUT + 14,2V

Sorties lectriques de signalisation dALARME BLOC A , ALARME BLOC B et AUTOPROTECTION. 23 OUT 1 (ALARME A) La temporisation est ajuste au moyen du potentiomtre Pt2 de 2 10 minutes. 24 OUT 2 (ALARME B) 25 OUT 3 (AUTOPROTECT.) 27 COMMUN 28 N.F. (OUT 4) 29 N.O. 32 K 33 + K 34 LED A 35 LED B 36 K MEC Sortie relais pour ALARME BLOC A, ALARME BLOC B ET AUTOPROTECTION La temporisation est ajuste au moyen du potentiomtre Pt2 de 2 10 minutes. Entre LECTEURS ou CLAVIERS. A relier en parallle sur tous les lecteurs ou claviers prsents Les sorties LED A et LED B seront relies sur les voyants des LECTEURS ou des CLAVIERS Entre CLEF MECANIQUE de type N.F. Borne ferme sur GND : centrale larrt, ouverte : centrale en service

IMPORTANT : Pour conserver le degr de protection de lenveloppe IP 3X selon les normes CEI 79.2 deuxime dition, faire rentrer les cbles par larrire du boitier. Pour les raccordements il est recommand dutiliser un cble blind (section: 0,2 mm min). Lcran devra tre reli la borne GND de la centrale et sera libre lautre extrmit.

14

3) PROGRAMMATIONS CAVALIER P1: programmation du fonctionnement BLOCS (Enlev EN SORTIE USINE): CAVALIER P1 Enlev 1 BLOC POSITION A CODES ou CLEFS 1 CLEF ou CODE 1 CLEF MECANIQUE FONCTIONNEMENT UN SEUL BLOC ET UNE SEULE CLEF OU UN SEUL CODE UN SEUL BLOC ET UNE CLEF MECANIQUE SUR LA BORNE 36 (K MEC): - dispositif ferm sur GND : centrale larrt; - dispositif ouvert : centrale en service. POSITION B POSITION C 2 BLOCS POSITION D 2 CLEFS ou CODES 1 CLEF ou CODE 2 CLEFS ou CODES DEUX BLOCS (A = zones 1/2 - B = zones 3/4) ET UNE CLEF OU UN CODE AVEC MISE EN SERVICE CYCLIQUE = A - B - A+B - ARRET DEUX BLOCS (A = zones 1/2 - B = zones 3/4) ET DEUX CLEFS OU DEUX CODES AVEC MISE EN SERVICE SEPAREES Clef 1 ou Code 1 : mise en et hors service BLOC A; Clef 2:ou Code 2 : mise en et hors service BLOC B. DEUX BLOCS (A = zones 1/2 - B = zones 3/4) ET DEUX CLEFS OU DEUX CODES AVEC MISE EN SERVICE SEPAREES Clef 1 ou Code 1 : mise en et hors service BLOC A et BLOC B; Clef 2:ou Code 2 : mise en et hors service BLOC A.

CAVALIER P2: programmation sortie ET/OU MARCHE (Enlev EN SORTIE USINE): P2 en place P2 enlev fonction OU sur borne 14: la sortie change de polarit lun des deux blocs est en service. Polarit voir P4 fonction ET sur borne 14: la sortie change de polarit SI les deux blocs sont en service. Polarit voir P4

CAVALIER P3: programmation de ljection des ZONES (ENLEVE EN SORTIE USINE ): P3 en place P3 enlev Les zones sont toujours en fonction. A chaque dtection correspond un cycle dalarme. Les zones sont jectes aprs 3 cycles dalarme. Aprs 3 cycles dalarme les dtections successives ne provoqueront pas dautres cycles dalarme. Les zones ainsi jectes seront rarmes automatiquement la mise en service successive.

CAVALIER P4: programmation polarit sorties MARCHE (HABIL) (EN PLACE EN SORTIE USINE): P4 en place P4 enlev La borne donne un ngatif quand la centrale est larrt et un positif en marche La borne donne un positif quand la centrale est larrt et un ngatif en marche

CAVALIER P5: programmation polarit sorties OUT 1-2-3 (En place EN SORTIE USINE): P5 en place P5 enlev La borne donne un positif au repos et un ngatif en alarme. La borne donne un ngatif au repos et un positif en alarme.

CAVALIER P6: programmation polarit ENTREE PANNE (En place EN SORTIE USINE): P6 en place P6 enlev A lentre PANNE/EXT il faudra relier la sortie de contrle batterie de la sirne externe ngative lorsque la batterie est charge. A lentre PANNE/EXT il faudra relier la sortie de contrle batterie de la sirne externe positive lorsque la batterie est charge. 4) Rglage des temporisations au moyen des potentiomtres: Pt1: rglage du retard dentre sur la ZONE 1 (0 60 sec.). en agissant sur le potentiomtre dans le sens des aiguilles dune montre on peut rgler le retard de 0 secondes 60 secondes. Le retard de sortie sera automatiquement le double du retard dentre. Pt2: rglage de la temporisation des sirnes : en agissant sur le potentiomtre dans le sens des aiguilles dune montre on peut rgler la temporisation de 2 10 min.).

15

6) PROCEDURE DINITIALISATION DE LA CENTRALE Lorsque les raccordements sont effectus ainsi que les programmations Il est alors possible dinitialiser la centrale. 6a) Lecture des programmations La platine de la centrale vrifie la position des cavaliers au moment ou elle reoit lalimentation : fournir donc lalimentation et vrifier que toutes les LED sallument pendant une seconde puis steignent (si la centrale est programme pour fonctionner avec deux BLOCS les LED sallumeront deux fois). Relier la batterie aux cbles prvus cet effet en ayant soin de respecter la polarit et passer la phase successive. Cette deuxime phase dpend de la position du cavalier P1 et du fait que lon travaille avec un ou deux blocs. De toutes faons il faudra mmoriser les codes ou clefs selon la procdure suivante : UTILISATION AVEC UN SEUL BLOC (BLOC A):

Mise en service par clef mcanique avec cavalier P1 en position A: - Le dispositif de commande est reli sur la borne 36 (K MEC) et fonctionne comme suit : - dispositif ferm sur GND : centrale larrt; - dispositif ouvert : centrale en service. En ce cas il ny a quun seul bloc (A). On peut passer galement en TEST et effectuer toutes les oprations de contrle de linstallation Mise en service avec un seul code ou clef et avec le cavalier P1 enlev : - Lire la clef digitale sur le lecteur ou saisir le code sur le clavier bus puis vrifier que la LED A du lecteur ou du clavier clignote pendant 1 seconde. UTILISATION AVEC DEUX BLOCS (BLOC A et BLOC B): Mise en service avec une seule clef ou code et cavalier P1 en position B : - Lire la clef digitale sur le lecteur ou saisir le code sur le clavier bus puis vrifier que la LED A du lecteur ou du clavier clignote pendant 1 seconde. Gestion de linstallation avec deux clefs ou deux codes: - Clef 1 ou Code 1 : gestion du BLOC A; - Clef 2 ou Code 2 : gestion du BLOC B. Le cavalier P1 est en position C: - Lire la clef 1 sur le lecteur ou saisir le code 1 sur le clavier bus puis vrifier que la LED A du lecteur ou du clavier clignote pendant 1 seconde. - Lire la clef 2 sur le lecteur ou saisir le code 2 sur le clavier bus puis vrifier que la LED B du lecteur ou du clavier clignote pendant 1 seconde. IMPORTANT: pour passer ensuite en TEST il faudra arrter les DEUX BLOCS. Gestion de linstallation avec deux clefs ou deux codes: - Clef 1 ou Code 1 : gestion des BLOCS A et B; - Clef 2 ou Code 2 : gestion du seul BLOC A. Le cavalier P1 est en position D: - - Lire la clef 1 sur le lecteur ou saisir le code 1 sur le clavier bus puis vrifier que les LED A et B du lecteur ou du clavier clignotent pendant 1 seconde. - Lire la clef 2 sur le lecteur ou saisir le code 2 sur le clavier bus puis vrifier que la LED B du lecteur ou du clavier clignote pendant 1 seconde. La centrale est maintenant A LARRET : Vrifier que la LED TEST soit allume puis (dans les 30 sec.): - Appuyer sur la touche RESET jusqu ce que le systme passe en condition de TEST; - vrifier que les LED A et LED B clignotent ALTERNATIVEMENT (CONDITION DE TEST) Passer maintenant la phase de contrle de linstallation : 7) CONTROLE INSTALLATION Les sorties OUT MARCHE A (borne 12), OUT MARCHE B (borne 13), ET/OU MARCHE (borne 14) tant actives tous les dtecteurs seront galement actifs et il sera possible de rgler la porte de ceux-ci et de les contrler De plus les sorties OUT 1 (borne 23) OUT 2 (borne 24) OUT 3 (borne 25) OUT 4 (bornes 2729) sont bloques. Nous vous rappellons que : - SEUL en TEST, les LED qui correspondent aux zones clignotent avec la LED du BLOC A lorsquils ont mmoris une dtection, tout comme les LED des ZONES du BLOC B clignotent avec la LED du BLOC B. A la fin de ces oprations : refermer tous les dtecteurs; relier sirnes et transmetteurs; refermer la centrale; appuyer sur la touche RESET jusqu ce que le systme ABANDONNE LE TEST; vrifier que les LED A et LED B steignent;

16

8) EMPLOI DE LA CENTRALE PULSAR 4 Lorsque lINITIALISATION de la centrale est effectue, la centrale se trouve larrt prte tre utilise. IMPORTANT : avant deffectuer les oprations de mise en et hors service il convient de sassurer que la ligne dautoprotection est correctement ferme sinon il ne sera pas possible de mettre en service la centrale. En cas dAUTOPROTECTION la LED du BLOC EN SERVICE clignote. 8a) MISE EN SERVICE ET ARRET DU SYSTEME La MISE EN SERVICE et LARRET du systme seffectuent soit en LISANT LA CLEF SUR UN LECTEUR soit EN SAISISSANT UN CODE SUR LE CLAVIER. A chaque manoeuvre on passe dun tat lautre et en outre : - les signalisations dALARME et dAUTOPROTECTION sont masques pendant 8 secondes. - les sorties OUT MARCHE A, OUT MARCHE B, OUT ET/OU MARCHE sont actives avec un retard de 8 secondes. Avec le seul BLOC A En ce cas cest la LED A du LECTEUR ou du CLAVIER qui fournit les indications suivantes : - LED clignotante la lecture de clef ou saisie de code : DEFAUT DE ZONE OU AUTOPROTECTION (appuyer sur la TOUCHE RESET et contrler les ZONES) - LED allume : CENTRALE EN SERVICE - LED teinte : CENTRALE A LARRET - LED clignotante quand la centrale est en service : MEMOIRE DALARME. Une ou plusieurs alarmes ont eu lieu pendant la priode de MISE EN SERVICE. Avec les BLOC A et BLOC B En ce cas ce sont les LED A et B des LECTEURS ou des CLAVIERS qui fournissent les indications suivantes : - LED clignotante la lecture de clef ou saisie de code : DEFAUT DE ZONE OU ou AUTOPROTECTION (appuyer sur la TOUCHE RESET et contrler les ZONES) - LED allume: CENTRALE EN SERVICE - LED teinte : CENTRALE A LARRET - LED clignotante quand la centrale est en service : MEMOIRE DALARME. Une ou plusieurs alarmes ont eu lieu pendant la priode de MISE EN SERVICE. - Une LED allume et lautre teinte : un seul BLOC EN SERVICE; - Les deux LED allumes : Les DEUX BLOCS sont EN SERVICE. IMPORTANT Si une CLEF ou un CODE pilotent DEUX BLOCS le cycle est MARCHE A - MARCHE B - MARCHE A+B - ARRET sauf si lon laisse passer 5 secondes entre deux manoeuvres car on obtiendra le cycle suivant : MARCHE A - ARRET 8b) Indications lumineuses Lorsque lon met HORS SERVICE les deux blocs les LED 1,, LED 4 deviennent oprationnelles. Les alarmes qui ont eu lieu sont alors mmorises et mises en vidence par un clignotement sur le LED de la zone concerne. Les LED PANNE et LED AUTOPROTECTION mmorisent quant elles les conditions PANNE et AUTOPROTECTION. 8c) Effacement mmoires Leffacement des mmoires est effectu en appuyant pendant 1 seconde sur la TOUCHE RESET lorsque la LED TEST est allume cest--dire dans les 30 secondes qui suivent la MISE HORS SERVICE des BLOCS A et B. 8d) TEST La condition de TEST est obtenue de la faon suivante - mettre HORS SERVICE les DEUX BLOCS - avant que 30 secondes ne scoulent appuyer sur la TOUCHE RESET jusqu ce que la centrale passe en TEST - La condition de TEST est mise en vidence par le clignotement ALTERNE des LED A et LED B sur la centrale et des LED A et LED B des LECTEURS ou CLAVIERS - vrifier que la LED TEST reste allum En TEST la situation est la suivante - LED 1 ,, LED 4 oprationnelles - TOUCHES toujours en service - signalisations ALARME et AUTOPROTECTION absentes - sorties lectriques OUT MARCHE A, OUT MARCHE B, ET/OU MARCHE prsentes - sortie lectrique OUT PANNE oprationnelle - OUT 1 (borne 23) OUT 2 (borne 24) OUT 3 (borne 25) OUT 4 (bornes 2729) ne sont pas oprationnelles WALK-TEST En condition de TEST les dtecteurs sont oprationnels. Ainsi il est possible deffectuer les essais de DETECTION ou WALK-TEST Le rsultat du WALK-TEST est mmoris sur les LED 1 ., LED 4; Leffacement des mmoires est effectu en appuyant sur la TOUCHE RESET pendant 1 seconde 9) SUBSTITUTION DES CLEFS OU CODES DE MISE EN SERVICE Pour changer les CLEFS ou CODES utiliss il faut dabord passer en TEST - mettre HORS SERVICE les DEUX BLOCS - avant que 30 sec. ne scoulent appuyer sur la TOUCHE RESET jusqu ce que le systme passe en TEST; - La condition de TEST est mise en vidente par le clignotement altern des LED A et LED B en centrale et des LED A et LED B des LECTEURS ou CLAVIERS; - Vrifier que la LED TEST reste allume. - Lire la CLEF sur le LECTEUR ou saisir le CODE que lon souhaite changer ; - vrifier que toutes les LED de la centrale sallument pendant 1 seconde environ puis steignent; - effettuer la lecture des nouvelles CLEFS ou des nouveaux CODES selon la procdure indique au paragraphe (6c); Comment sortir de la condition de TEST ? Pour sortir de la condition de TEST appuyer sur la TOUCHE RESET jusqu ce que la centrale passe automatiquement lARRET IMPORTANT: En TEST il est facile deffectuer toutes les oprations de MAINTENANCE sur linstallation en effet tous les boitiers pourront rester ouverts sans dclancher lAUTOPROTECTION.

17

10) CHANGEMENT DE CONFIGURATION SYSTEME Pour changer les programmations effectues sur la centrale : - passer en condition de TEST; - enlever le couvercle de la Centrale; - changer les programmations; - sortir du TEST en appuyant pendant 3 secondes sur la TOUCHE RESET - appuyer pendant quelques secondes sur la TOUCHE INIT situe sur la platine de la CENTRALE; - initialiser la centrale en suivant la procdure illustr au paragraphe (6). IMPORTANT A partir du moment ou lon appuie sur la TOUCHE INIT toutes les signalisations sur les sorties OUT 1 (borne 21) OUT 2 (borne 22) OUT 3 (borne 23) OUT 4 (bornes 2527) sont bloques jusqu la fin de la procdure dinitialisation cest--dire de la LECTURE DES CLEFS ou la SAISIE DES CODES.

EN CAS DE DIFFICULTE PROBLEME


LED AUTOPROTECTION ALLUME FIXE

SOLUTION
- Vrifiier que la borne 10 soit ferme sur GND (si non utilise) ou encore quil ny ait pas une autoprotection ouverte sur dautres dispositifs relis cette ligne. - Vrifier la correcte fermeture du dispositif de protection du boitier. - Si la fonction nest pas utilise, fermer GND la borne 11 et mettre le pontet P6 en place. - Si vous utilisez la borne 11, changer la programmation du pontet P6. - Une ou plusieurs zones sont-elles en condition dalarme? Passer en TEST et vrifier au moyen des LED 14 la zone en dfaut puis assurez-vous que celle-ci soit ferme avant de mettre en service. - Toutes les zones sont-elles hors-service ? Si les (LED 14 sont teintes, mettre en service au moins une zone au moyen des touches14. - La LED de lautoprotection est-elle allume ? Suivre la mme procdure.

LED PANNE ALLUME FIXE

EN SAISISSANT LE CODE OU EN LISANT LA CLEF LA LED CLIGNOTE MAIS IL EST IMPOSSIBLE DE METTRE EN SERVICE

VOUS SOUHAITEZ CHANGER LA PROGRAMMATION DES PONTETS (P1P6)

- Programmer les pontets comme vous le souhaitez puis appuyer sur la touche INIT jusqu ce que toutes les LED sallument et enfin mmorisez de nouveau les CLEFS ou saisissez de nouveau les CODES utiliss sur le systme.

18

D P1

1
A

SCHEMA PULSAR 4 AVEC UN SEUL BLOC BLOC A = ZONE 1 + ZONE 2 + ZONE 3 + ZONE 4
GND
Pt1
C

Retard entre (0 60 sec.)

2 3
P2 P3 P4 P5 P6

ZONE 1 ZONE 2
Pt2

~ 230V

+ ALIM

INIT

RESET

CENTRALE PULSAR 4 PROGRAMMATION :

GND

Tempo sonnerie sirnes (2 10 min.)

6 7
ZONE 3

+ ALIM

1- K 2+K 3 + LED R 4 + LED V 5 + LED G 6 GND LED

P1 = OFF P2 = ON P3 = OFF P4 = ON
ZONE 4 GND IN A/P

P5 = ON P6 = ON
IN G/EXT.

MISE EN SERVICE PAR CLEF DIGITALE/CLAVIER FONCTION "OR" SUR BORNE 14 EJECTION DES ZONES APRES 3 ALARMESI EN MARCHE : BORNES 12, 13, 14 A POSITIF A LARRET : BORNES 12, 13, 14 A NEGATIF SORTIES OUT1, OUT2 ET OUT3 POSITIVES AU REPOS IN PANNE PROGRAMMEE POUR SIRENES AVEC SORTIES (C/BATT) DE TYPE N.F. A NEGATIF

OFF= ENLEVE ON = EN PLACE

MARCHE A

TEST

MARCHE B

SIRENE ECHO 30: PROGRAMMATION


OUT PANNE
COM K MEC OUT 1 OUT 2 OUT 3 GND GND GND + 14,2V LED A LED B + ALIM N.O.

9 10 11 12 13 14 15 16
AND/OR MARCHE OUT PREALARME
N.F. +K K

IN 4
P4

P1 = POS. A -C/SIR SUR POSITIF: SIRENE BLOQUEE; -C/SIR SUR NEGATIF OU OUVERTE : SIRENE EN FONCTION.
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36

1 2 3 4 5 6 7

P1 A B

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

TAMPER TAMPER C/SIR GND + ALIM

IN 3
P4

1 2 3 4 5 6 7

TRANSMETTEUR REPORTER 2000: MESSAGE 1 =ALARME et AUTOPROTECTION MESSAGE 2 = BATTERIE DECHARGEE

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

TEL.

TEL.

IN 2
P4

LIGNE

1 2 3 4 5 6 7

LIGNE

BATT

39

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3

+ BATT

10

IR POLARIS: PROGRAMMATION

TAMPER

TAMPER
29 10 17 15

P1 = ON (LED ACTIF) P2 = POS. A (DET BLOQUE PAR GND) P3 = ON (COMPTAGE PAR 2) P4 = ON PORTEE 16 METRES

OUT TLC

41

GND

10

IN 1
P4

ABIL1

18
BATT.

IN2

52

MICRO SWITCH

IN1

51

LAMP.

1 2 3 4 5 6 7

+ 14 V

29

TAMPER TAMPER C/SIR + C/SIR C/BATT GND + 14,2 V

GND

10

+ ALIM - ALIM ALL ALL ABIL TAMPER TAMPER


P1 B

P2 A

P3