CENTRIFUGAL FANS

TYPE LSV/MSV/HSV

APPLICATIONS The centrifugal fans LSV, MSV and HSV are designed for marine use. The fans can be used for both as supply and exhaust fans. Typical applications for low and medium pressure fans are galley fans, mess room, sanitary spaces, dayroom, technical rooms etc. Often it can be used as a central with a plenum suction chamber for multiple duct connections. High pressure fans are often used for gas freeing for LPG tankers, chemical tankers etc.

OPTIONAL EXECUTION Fan housing and impeller in aisi316L execution. Steel - galvanized or galvanized and painted execution are delivered on request. IMPELLERS: The impeller is as standard delivered in the same material as the fan housing, as standard salt- and ammonia resistant aluminium, dynamically balanced. The impellers are divided into four main groups: B - type: The standard impeller for the centrifugal fans. This is a cost effective impeller with high efficiency. Z type: Self cleaning impeller, ideal for applications where dust or material in the air stream can build up on the impeller and cause imbalance. F type: Forward curved blades (sciroccio impeller) for applications where high air flow are required. This impeller is only delivered for the smaller centrifugal fans. R type: heavy duty impeller with radial blades for transport applications (e.g. saw dust for wood industry or similar).

DESIGN The MSV / LSV / HSV fans are single inlet centrifugal fans with direct drive as standard. The design is based on three main groups, low, medium and high pressure. LSV - Low pressure: pressures up to 3 4000Pa, capacities up to 120.000m /h with duct connection 250 to 1200mm. MSV - Medium pressures up to 8.000Pa, 3 capacities up to 95.000 m /h with duct connection 125 to 900mm. HSV - High pressure up to 30.000 Pa. 3 capacities up to 45.000 m /h with duct connection 60 to 500mm.

EXECUTION The fan housings and impeller are as standard manufactured in sea water resistant aluminium and painted. This gives a corrosion resistant fan and a spark proof design.

ELECTRIC MOTOR The motors are as standard TEFC squirrel caged inductive electric motors in marine execution. Motors are IP55 and insulation class F as standard. The fans can also be equipped with EX motors for hazardous applications. Motor options: IP56, IP65 or IP66, anti condensing heating element offshore painting Vibration monitoring O R G A S

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

CENTRIFUGAL FANS

TYPE LSV/MSV/HSV

PERFORMANCE Fan curves are given for standard air 1,2kg/m3 and temperature 20deg.

ACCESSORIES - Vibration dampers - Flexible connections inlet/outlet - Protection grid inlet/outlet - Base frame - Motor pedestal (required for heavy motors) - Flanged inlet - Counter flange inlet/outlet - Inspection hatch - Drain plug - Earthing plug for fan / motor pedestal - Ex execution with anti-spark track (for stainless steel and steel execution) - Suction chamber on inlet - Iris / regulating damper - (Diffuser on outlet)

SPECIAL DESIGNS - Belt driven execution - With gas tight motor flange (for EX applications where motor can be placed outside hazardous area) - With coupling drive - With coupling drive and cooling wheel (air cooled) for high temperature applications. - Portable execution (only smaller fans) - With water-, air- or hydraulic driven motor.

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

CENTRIFUGAL FANS
LSV - B1 LSV - B1 LSV - B3

MSV - B1

MSV - B1

MSV - B2

HSV - B1

HSV - B3

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

CENTRIFUGAL FANS selection curves


(50Hz)

LSV and MSV

3000 2750 2500 2250

Static pressure, Ps [Pa]

2000 1750 1500 1250 1000 750 500 250 0 0 2000 4000 6000 8000
3

8 5

3 1 2 6

10 9
10000 12000 14000 16000 18000

Q [m /h]
150 100 50

0,0

0,5

1,0

1,5

2,0

2,5

3,0

3,5

4,0

4,5

5,0

q [m /s]

Curve 1 2 3 4 5 6 7 8 9 10

Fan MSV 125 B1 MSV 160 B1 MSV 200 B1 MSV 250 B1 MSV 315 B1 LSV 250 B1 LSV 315 B1 LSV 400 B1 LSV 500 B1 LSV 600 B1

rpm 2900 2900 2900 2900 2900 2900 2900 2900 1450 1450

Fan power cons. [kW] 0,34 0,58 1,18 3,4 5,5 0,88 1,92 7,5 2,4 3,8

Sound press. [dBA] 1m 70 75 79 85 88 75 81 88 76 81

Motor 71M02K 80M02K 90S02 112M02 132S02K 80M02 90L02 132S02 100L04 112M04

Motor power [kW] 0,37 0,86 1,5 4 5,5 1,1 2,2 7,5 3 4

Current Current [A] [A] (400V) (230V) 1,05 1,85 3,5 8,2 11,7 2,55 4,8 15 7 9,3 1,9 3,35 6,1 14,2 19,6 4,4 8,4 25,5 12 16

N Y B O R G
nybmw_06-01 01.mar.06

A S

N-6230 Sykkylven, Norway TEL +47 7025 4080 - FAX +47 7025 2908 office@nyborgfan.com - www.nyborgfan.com

LSV and MSV

CENTRIFUGAL FANS selection curves


(60Hz)

LSV and MSV

4500 4000 3500

Static pressure, Ps [Pa]

3000 2500 2000 1500 1000 500

7 1 2
2000

3
4000

8
6000

4
8000

5
10000

9
12000 14000 16000

10
18000 20000

0 0

Q [m /h]
150 100 50

0,0

0,5

1,0

1,5

2,0

2,5
3

3,0

3,5

4,0

4,5

5,0

5,5

q [m /s]

Curve 1 2 3 4 5 6 7 8 9 10

Fan MSV 125 B1 MSV 160 B1 MSV 200 B1 MSV 250 B1 MSV 315 B1 LSV 250 B1 LSV 315 B1 LSV 400 B1 LSV 500 B1 LSV 600 B1

rpm 3500 3500 3500 3500 3500 3500 3500 1750 1750 1750

Fan power cons. [kW] 0,58 1,02 2,08 6,1 9,6 1,55 3,4 1,55 4,2 6,7

Sound press. [dBA] 1m 75 80 83 89 93 82 85 72 79 84

Motor 71M02 80M02 90L02 112M02 132M02 90S02 100L02 90L04 112M04 132M04

Motor power [kW] 0,63 1,3 2,55 6,3 12,6 1,75 3,45 1,75 4,6 8,6

Current [A] (440V) 1,4 2,5 4,8 11 20,6 3,4 6,3 3,6 8,8 16

N Y B O R G
nybmw_06-02 01.mar.06

A S

N-6230 Sykkylven, Norway TEL +47 7025 4080 - FAX +47 7025 2908 office@nyborgfan.com - www.nyborgfan.com

LSV and MSV

MOUNTING POSITIONS IN ACCORDANCE TO EUROVENT CENTRIFUGAL FANS


LG 0 (2H) LG 315

LG 270 (1H) LG 45 LG 90 (3H) LG 225

LG 135

LG 180 (4H) RD 0 (2V) RD 315

RD 270 (1V) RD 225 RD 45 RD 90 (3V)

RD 135 RD 180 (4V)

06.12.00 F. stro 4-2013-1

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

Centrifugal Fans
Explanation of Fan Model Number

Fan model number is stated in the following way: Centrifugal Fan model MSV 160 B1. MSV figure no 1-3 160 Figure no 4-6 B 7 1 8

1. - 3. figure: LSV MSV HSV, HZV, HRV

: : :

Low pressure centrifugal fan Medium pressure centrifugal fan High pressure centrifugal fan

4. -6. figure: The size of the fan. The numbers refers to nominal diameter (mm) on the fans suction flange.

8.figure 1: 2: 3: Direct driven. impeller mounted on motor shaft Belt driven. motor placed alongside the fan Belt driven. motor mounted on the fan, belt screened

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

SOUND POWER LEVELS (SWL) CALC. NYBORG CENTRIFUGAL FANS

FAN DATA FAN MODEL LSV 250 B LSV 250 B LSV 315 B LSV 315 B LSV 400 B LSV 500 B LSV 600 B MSV 125 B MSV 160 B MSV 200 B MSV 200 B MSV 250 B MSV 250 B MSV 315 B MSV 315 B Rpm Impeller 1450 2900 1450 2900 1450 1450 1450 2900 2900 1450 2900 1450 2900 1450 2900 B12x300x80 B12x300x80 B12x350x100 B12x350x100 B6x450x100 B7x550x125 B7x650x140 B9x250x50 B12x300x60 B12x350x70 B12x350x70 B12x400x80 B12x400x80 B12x450x90 B12x450x90 63 80 90 84 96 92 98 103 72 93 76 99 84 90 95

dB values at centre Hz 125 250 500 1000 2000 70 85 74 91 82 88 93 62 84 66 90 74 80 85 79 83 65 91 70 94 73 97 62 76 66 82 74 80 85 71 75 66 83 70 86 73 89 57 75 61 81 69 75 80 70 74 60 82 65 85 68 88 4000 54 71 58 77 66 72 77 66 70 57 78 63 81 65 84 8000 52 67 56 73 64 70 75 62 66 55 74 60 77 63 80

Theor dBA 57 75 61 81 70 76 81 70 75 60 79 65 85 69 88

85 88 80 89 92 84 83 75 73 97 100 92 88 80 78 100 103 95 91 83 81 103 106 98

Sound power levels in dB. ref. 10 -12 W, internal values in fan openings. dBA values applies to 1 m. distance based on a theoretical free field environment. The sound power level values above are only intended as a guide, and may be used for calculations for sound pressure levels. (heard by the human ear).

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

SOUND POWER LEVELS (SWL) CALC. NYBORG CENTRIFUGAL FANS

FAN DATA FAN MODEL LSV 250 B LSV 250 B LSV 315 B LSV 315 B LSV 400 B LSV 500 B LSV 600 B MSV 125 B MSV 160 B MSV 200 B MSV 200 B MSV 250 B MSV 250 B MSV 315 B MSV 315 B Rpm Impeller 1750 3500 1750 3500 1750 1750 1750 3500 3500 1750 3500 1750 3500 1750 3500 B12x300x80 B12x300x80 B12x350x100 B12x350x100 B6x450x100 B7x550x125 B7x650x140 B9x250x50 B12x300x60 B12x350x70 B12x350x70 B12x400x80 B12x400x80 B12x450x90 B12x450x90 63

dB values at centre Hz 125 250 500 1000 2000 67 90 70 93 78 84 89 65 84 68 87 76 82 87 78 83 67 86 73 91 77 95 61 81 64 84 72 78 83 75 80 63 83 69 88 73 92 4000 58 77 61 80 69 75 80 71 76 60 79 66 84 70 88 8000 55 74 58 77 66 72 77 68 63 57 76 63 81 67 85 82 76 74 95 98 93 85 79 77 98 101 96 93 87 85 99 93 91 104 98 96

Theor dBA 61 82 64 85 72 79 84 75 80 63 83 70 89 73 93

89 92 87 84 94 97 92 89 84 78 76 69 97 100 95 93 90 84 82 75 102 105 100 97 94 88 86 79 106 109 104 101

Sound power levels in dB. ref. 10 -12 W, internal values in fan openings. dBA values applies to 1 m. distance based on a theoretical free field environment. The sound power level values above are only intended as a guide, and may be used for calculations for sound pressure levels. (heard by the human ear).

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

PAINTING SPECIFICATION ALUMINIUM FANS

Surface preparation: Step No


1

Description Washing Cleaning

Thickness
-

Type Aluminate (acid) Water

Manufacturer Alu-Nor
-

Painting : Color RAL 5012 Step No


1

Description Primer Topcoat

Thickness 30 my 40 my

Type

Manufacturer

Joton Washprimer Jotun Jotun Ultra Topcoat Jotun

GALVANIZE SPECIFICATION STEEL FANS


Surface preparation: Step No
1

Description Cleaning Galvanizing

Thickness
-

Type Nitric acid Zn

Manufacturer
-

80my

N-6230 SYKKYLVEN, NORWAY TEL +47 70 25 40 80 - FAX +47 70 25 29 08 office@nyborgfan.com - www.nyborgfan.com

You might also like