21.9

Xt6

BUILDERS METALWORK A P R 10

BUILDERS METALWORK
Product Brochure

CONTENTS
Page Illustration Key

SPH Joist Hangers Maxi Speedy Joist Hanger Speedy Joist Hangers Straps Herringbone Joist Struts Truss Clip Wall Ties

4-5 6-7 8-9 10 11 11 12

1 2 3 4 5 6 7

Movement, Screw-in Starter and Cavity Ties 13 Safe Edge Frame Cramp Screw-in Frame Ties Security Mesh Flat Wire Reinforcement Exmet Framing Anchors Angle Plate Angle Brackets Timber Connectors BAT-U-Nailplate Splice Plates Frame Cramp Sole Plate Angles Junction Clip BAT Safeplate Multi-purpose Fixing Band Soffit Vent Mesh Scrolled Hip Irons Nails Gallows Brackets Wall Starter/UniStarter/Multi-Starter 14 14 14 15 15 16 17 18 - 20 21 21 22 23 23 24 24 24 25 26 26 26 27 - 29 15 14 10 11 12 13 9 8

10

These products meet the requirements of the BM TRADA Certification Scheme for Timber Engineering Hardware
Timber Engineering Hardware
Certificate Number 0004

Safe working loads are based upon the use of C16 dry graded timber in Service Class 1 or 2 (Eurocode 5).

12 4 1 14

5 11 7 15 13 3

EXPAMET SPH JOIST HANGERS


The BAT S.P.H. Joist Hanger is a single piece timber to masonry hanger for building into the inner leaf of external cavity walls and internal walls.
G Wider masonry flange to increase loadings on masonry of

Design Features
G Single-piece, non- welded construction.

compressive strength 2.8N/mm2 and greater.


G Manufactured from 2mm thick pre-galvanised mild steel to

BS EN 10327 : 2004, DX51D + Z600.


G 75mm load bearing surfaces. G All hangers 150mm deep and over are manufactured 10mm less to

75mm

allow for notching and regularisation of timber joists.


G Gusset nail holes are non coaxial. G Standard available widths 38, 44, 47, 50, 63, 75, 100, 125, 150mm.

Installation Requirements
Standard Type S

The back face of hanger must be flush against the wall. The timber joist should be square cut and butting to the back face of the hanger (maximum permitted gap 6mm). A minimum height of 675mm of set masonry must be in position above the supporting flange before any load is applied. Fixing: Nail to the joist through the nail holes in each side gusset with BAT 3.75 x 30mm long square twisted sherardised nails. It is recommended that joists are notched for the base of the hanger to achieve a level surface for plasterboarding. Type R and ST provide additional location and alignment during construction. HD Restraint Straps must be used with all types of SPH joist hangers to provide lateral restraint.
Return Type R (R Type is a Standard type S with Return Plate added).

How to Order/Specify BAT SPH Joist Hangers


TYPE S
Please state dimensions of joist (a) depth (b) width e.g. SPHS22550 Minimum box quantity dependent on hanger size.

TYPES R & ST (made to order)


Please state dimensions of joist (a) depth (b) width (c) top flange (to suit wall width) e.g. SPH22550R100 Quantity made to order
Both the R and ST Type enables the hangers to be positioned accurately whilst the masonry is built above.

Straddle Type ST (ST Type is two Standard Joist Hangers joined together with Jointing Plate).

EXPAMET SPH JOIST HANGERS

Safe Working Loads of the S.P.H. Joist Hanger used with various types of masonry
M a s o n r y S t re n g t h 2 . 8 N / m m 2
* not available

M a s o n r y S t re n g t h 4 . 0 N / m m 2
Nominal Joist Depth (mm) S.P.H. Hanger Depth (mm)

Nominal Joist Depth (mm)

S.P.H. Hanger Depth (mm)

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

3.08 3.21 3.28 3.40 3.52 3.65 3.65 3.65

2.86 2.98 3.05 3.07 3.29 3.43 3.43 3.43

* * * * * * * *

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

2.84 3.06 3.19 3.41 3.64 3.87 3.87 3.87

2.93 3.18 3.33 3.57 3.83 3.87 3.87 3.87

4.17 4.17 4.08 3.99 3.90 3.81 3.81 3.81

M a s o n r y S t re n g t h 3 . 5 N / m m 2
Nominal Joist Depth (mm) S.P.H. Hanger Depth (mm)

M a s o n r y S t re n g t h 7 . 0 N / m m 2
Nominal Joist Depth (mm) S.P.H. Hanger Depth (mm)

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

38 to 50

Joist Widths (mm) 63 to 75 89 to 150

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

2.67 2.86 3.05 3.25 3.44 3.63 3.63 3.63

2.77 2.98 3.19 3.40 3.61 3.82 3.82 3.82

* * * * * * * *

100 125 150 175 200 225 250 275

100 125 140 165 190 215 240 265

3.13 3.55 3.80 4.22 4.63 5.05 5.05 5.05

4.29 4.65 4.87 5.22 5.58 5.94 5.94 5.94

4.47 4.47 4.42 4.36 4.31 4.25 4.25 4.25

EXPAMET MAXI SPEEDY


The Maxi Speedy is a heavy duty hanger for the support of Timber to Timber or Timber to Masonry, Concrete, etc with provision for Nailing or Bolting.

Design Features
G Manufactured from 1.5mm thick pre-galvanised mild steel to

BS EN 10327 : 2004, DX51D + Z275.


G Available in 7 types: MS240; MS335; MS380; MS440; MS500;
4.5 15

MS560 & MS620.


G Nail hole diameter: 4.5mm

40
23

35

Bolt hole diameter: 14mm


60 20 55 60

G Available widths: 38, 47, 50, 63, 75, 100mm (122 + 150 for MS500,

560 + 620 only

Installation Requirements
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails. M12 Bolts or Coach screws as specified by fixing manufacturer.

How to Order/Specify Maxi Speedy Joist Hangers


Type = Blank Length mm 240/335/380/440/500/560/620

14

38

to 1

50

mm

75

Bend Lines Joist Width W

Steps to specify requirements:


Type 380*

35
23

40

1. Joist dimensions: Double joist depth and add joist width, ie for joist 225 deep x 38mm wide then: 225 (d) + 225 (d) + 38 (w) = 488mm. 2. The Maxi Speedy blank length must be less than total calculated in step 1, therefore select MS44038 (not MS500 as the joist hanger would stand proud).
38mm 225mm

Type 335*

Type 240*

Type 440*

201mm Leg Length

20

4. 5

38

to 1

00

75

mm

w 6

* For lengths see calculations in How to Order.

Type 500*

14 .5 44

38

Type 560*

Type 620*

EXPAMET MAXI SPEEDY

Maxi Speedy Permissible Safe Working Loads (kN)

NAILS ONLY
Type 240 335 380 500 560 620 No. of Nails Into Face 12 18 20 32 38 44 SWL kN. 3.9 5.9 6.5 10.5 11.2 13.0 Type 240 335 380 500 560 620

BOLTS ONLY
No. of Bolts Into Face 2 4 6 6 6 8 SWL kN. 3.6 6.9 10.1 10.1 10.1 13.0

3.75 x 30mm long square twisted sherardised

M12 Bolts

COACH SCREWS
Type 240 335 380 500 560 620 No. of Coach Screws Into Face 2 4 6 6 6 8 SWL kN. 3.0 5.9 8.6 8.6 8.6 11.1 12mm 6 12mm 4 12mm 2

MASONRY ANCHORS
Bolt No. of Bolts Size Into Face SWLs for Masonry Strengths of 20N 7.2kN 15N 5.4kN 7N 2.5kN 5kN 7.5kN 3.5N 1.2kN 2.5kN 3.7kN 2.8N 1kN 2kN 3kN

14.4kN 10.5kN 21.0kN 15.5kN

12mm x 63mm long (min). USING STARTER HOLES

Indicative loads: refer to fixings supplier for recommended loads

EXPAMET SPEEDY JOIST HANGERS


SHORT-LEG/STANDARD-LEG SPEEDY SPEEDY MINOR

Speedy Joist Hangers provide a quick and safe method of joist trimming for light and medium duty joints.
m

SPEEDY MINOR

0.9

G Speedy Minor (SM)


34mm

Light duty applications. 100mm maximum joist depth to be supported.


G Short Leg (SL)
3.8mm

Depth 100 W = 38 : L = 70 W = 47 : L = 65 W = 50 : L = 64

Medium duty applications. 175mm maximum joist depth to be supported.


G Standard Leg (ST) & Long Leg (LLS)
W L

Medium duty applications. 225mm maximum joist depth to be supported.


G Speedy Girder Truss Shoe (SGTS)

36mm

Designed to offer a safe and economical method of connecting trusses to girder units. It incorporates a specially extended bearing surface of 85mm.
G Long Leg Speedy (LLS)
22 Holes 3.8mm 44mm

SHORT LEG SPEEDY

Medium duty 225mm maximum joist depth. Suitable for underslung joists (maximum 100mm drop).
G Girder/Girder Speedy

For connection of girder trusses.


0.9mm Side Gusset

Strap

Design Features
G Speedy Hangers

Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN


25mm

10327 : 2004, DX51D + Z275. Hole diameter: 3.8mm. LLS manufactured from 1.5mm thick material
G Girder/Girder Speedy
Depth 175 W = 38 : L = 191 : X = 76 W = 44 : L = 188 : X = 73 W = 47 : L = 186 : X = 71 W = 50 : L = 185 : X = 70 W Shoe 50mm

Manufactured from 3mm thick galvanised mild steel to BS EN 1461. Hole diameter: 22mm.

How to Order/Specify
Please quote type reference and joist width to be carried.

Installation Requirements
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails through all available nail holes.

Type

Joist Width (mm)


SM SL ST SGTS LLS GGTS 38, 47, 50 38, 44, 47, 50

Safe Working Load (kN)


1.6 3.4 4.3 7.1 6.7
See BS 5268 : Pt2

Speedy Minor Speedy Short Leg

For ease of use the legs are adjustable by hand to suit all varying depths of supporting timber. The depth of the supporting timber must not be less than the hanger side gusset height.

Standard Leg Girder Truss Shoe Long Leg Girder/Girder Speedy

38, 44, 47, 50, 63, 75, 100 38, 44, 47, 50, 75 38, 47, 50, 63, 75, 100 80, 105, 120, 155

EXPAMET SPEEDY JOIST HANGERS


GIRDER SPEEDY

34.5mm

Strap 29 Holes 3.8mm

Side Gusset

0.9mm L

Depth 225 W = 38 L = 281 W = 44 L = 278 W = 47 L = 276 W = 50 L = 275 W = 63 L = 268 W = 75 L = 262 W = 100 L = 250

36 nail holes Nails: 3.75 x 30mm long square twisted sherardised

X = 116 X = 113 X = 111 X = 110 X = 103 X = 97 X = 85

Depth 225 W = 38 L = 396 W = 47 L = 392 W = 50 L = 390 W = 63 L = 383 W = 75 L = 377 W = 100 L = 365

X = 137 X = 134 X = 131 X = 124 X = 118 X = 106

113mm 107mm X

35mm
W Shoe 25mm 50mm

50mm

STANDARD LEG SPEEDY (W = 38, 44, 47, 50, 63, 75, 100)
34 Holes 3.8m m 44m m

LONG LEG SPEEDY (W = 38, 47, 50, 63, 75, 100)

3 Holes 22mm Strap

1.2m m Side Gusset 20m m 25m m

W = 38 W = 44 W = 47 W = 50 W = 75

L = 271 L = 268 L = 267 L = 265 L = 252

X = 115 X = 112 X = 110 X = 109 X = 96

W = 80 W = 105 W = 120 W = 155

L = 550 L = 550 L = 550 L = 550

X = 490 X = 490 X = 490 X = 490

L 6 Holes 4mm

25m m W Shoe 85m m W 120mm

SPEEDY GIRDER TRUSS SHOE (W = 38, 44, 47, 50, 75)

GIRDER/GIRDER SPEEDY (W = 80, 105, 120, 155)

EXPAMET STRAPS
BAT straps are manufactured in two types. The Heavy Duty to provide horizontal restraint and Standard to provide vertical restraint against wind pressure and uplift forces.

STANDARD STRAP

HEAVY DUTY STRAP

3 27.5

Design Features
G The straps are manufactured from pre-galvanised steel strips

12. 5 25

12. 5

Dimensions
with zinc coated edges to BS EN 10327 : 2004, DX51D + Z275 or stainless steel to BS EN 10088-1 : 1995 : 1.4301.

50

Installation Requirements
G Nominal Dimensions

Heavy Duty - 27.5 x 5.0mm Standard - 27.5 x 2.5mm


G Hole diameters are 6mm and they are holed at 12.5mm

The installation of restraint straps must comply with the current Building Regulations, British Standards BS 5628 : Part 1 and Part 3 and BS 8103 : Part 1, as well as NHBC recommendations.

grouped in threes, diagonally across the width of the strap.

When straps are being fixed across joists or trussed rafters which are parallel with the wall, and where there is a gap between the wall and the first joist or truss, the gap must be packed. Noggins must be provided between each joist or truss. Fixing for Heavy Duty and Standard Straps: use either No 12 x 50mm wood screws or 4.00 dia x 75mm corrosion resistant nails. For stainless steel straps, stainless steel fixings must be used.

400 250

Anchorage of gable end to roof structure.

Fixing to wall plate and wall with one bend.

100

Floor level straps notched into parallel joists. Note: Gaps between masonry and adjacent joists must be packed.

Floor level straps. 150 x 650mm long once bent and once twisted fixed to perpendicular joists. Note: Turn down of the strap must be in contact with the masonry.

Illustration shows the standard clockwise rotation to strap. Anticlockwise is also possible.

Ordering
When ordering quote the overall length and distance of bend/twist from END of strap. eg. overall length, bent at 100mm, bent at 250mm, twisted at 400mm. E.g. HD1000B100, ST1000T400 If in doubt, provide sketch.

10

EXPAMET HERRINGBONE JOIST STRUTS


Herringbone Joist Struts provide stability to floor joists. Expamet Herringbone Joist Struts significantly reduce labour content in fixing strutting on site.

Fixing Detail
Single 3.75 x 30mm Sheradised Square Twisted Nail

Design Features
G Manufactured from 1mm thick pre-galvanised mild steel to BS EN

10327:2004 : DX51D + Z275.


G Suitable for joist widths between 38mm and 63mm, and joist

When fixing the second strut a 6mm (approx) gap should be kept between the struts.

depths between 150mm and 225mm.


G Available in 3 sizes:

Ref. HJS400 HJS450 HJS600

Joist Centres 400mm 450mm 600mm

Length 480mm 523mm 660mm

Qty/Box 50 50 50
Length

Installation Requirements
57mm

Joist Span 2.5m to 4.5m 1 Row at mid span greater than 4.5m 2 Rows at 1/3 span positions Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails.
4 Holes (both ends)

TRUSS CLIP

38 to 50

The Bat Truss Clip eliminates the disadvantages of skew nailing trussed rafters to timber wall plates; damaged connector plates; split rafters or wall plates.

12 Holes @ 4mm 117.5

28.5

Design Features
G Manufactured from 0.9mm thick pre-galvanised mild steel to BS EN
114.3 0.9 25.5 to 31

10327 : 2004, DX51D + Z275.


G Hole diameter:

4mm

Height: 117mm

G Available in 2 sizes:

Installation Requirements
Qty/Box 200 200 Safe Working Load Uplift (kN) 1.3 0.7 Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails. All nail holes must be filled. The timber wall plate must be securely held down onto the supporting masonry.

Ref. TC38 TC50

Width 38mm thick truss 50mm thick truss

G Other thicknesses of trussed rafters may be fixed using pairs of

BAT Framing Anchors, type MFAAL and MFAAR.

11

30mm

Power-Tie Wall Ties are manufactured to comply with BS EN 845 1 the specification for ancillary components for masonry, Part 1: ties, tension straps, hangers and brackets.

STAINLESS STEEL WALL TIES

DD140 and EN845-1 requires specific design characteristics allowing the designer to specify the correct type of Wall Tie for each situation. Wall Ties should be installed in accordance with BS 5628-3, the code of practise for the use of masonry, Part 3: materials and components, design and workmanship. Stainless steel type 1.4301 to BS EN 10088-1.

BS EN 845-1 Wall Ties


PART E
Party Walls TYPE

Type Reference

A
PT200#50 PT200 PT225#50 PT225

Nominal Cavity Width (mm)

Quantity

Classification

Description

Domestic up to 2 storey, 10m high. Part E (Separating Walls). Type A compliant.

75 75 100 100

5 x 50 250 5 x 50 250

Type 4 Type 4 Type 4 Type 4

200mm Housing Wall Tie 200mm Housing Wall Tie 225mm Housing Wall Tie 225mm Housing Wall Tie

PART E
External Walls

TYPE

Domestic and small commercial up to 15m high.

MPT200#50 MPT200 MPT225#50 MPT225 MPT250

75 75 100 100 125

5 x 50 250 5 x 50 250 250

Type 2 Type 2 Type 2 Type 2 Type 2

200mm General Purpose Wall Tie 200mm General Purpose Wall Tie 225mm General Purpose Wall Tie 225mm General Purpose Wall Tie 250mm General Purpose Wall Tie

PART E
External Walls

TYPE

Most masonry cavity walls.

PT1-200 PT1-225 PT1-250 PT1-275 PT1-300

75 100 125 150 150

250 250 250 250 250

Type 1 Type 1 Type 1 Type 1 Type 1

200mm Heavy Duty Wall Tie 225mm Heavy Duty Wall Tie 250mm Heavy Duty Wall Tie 275mm Heavy Duty Wall Tie 300mm Heavy Duty Wall Tie

PART E
External Walls

TYPE

DT200 DT225 DT250 DT300

75 100 125 150

250 250 250 250

Type 2 Type 2 Type 3 Type 3

200mm Double Triangle Wall Tie 225mm Double Triangle Wall Tie 250mm Double Triangle Wall Tie 300mm Double Triangle Wall Tie

SSCD

250

Insulation Retaining Disc. Fits all Ties.

Thin Joint Masonry Ties

PTJ4115 PTJ4135 PTJ4165

50 75 100

250 250 250

Type 4 Type 4 Type 4

Thin Joint Masonry Tie Thin Joint Masonry Tie Thin Joint Masonry Tie

Domestic up to 2 storey, 10m high. Maximum block density 550 kg/m3.

Timber Frame Tie

SSFS SSFS75 SSFS100

50 75 100

250 250 250

Type 6 Type 6 Type 6

Timber Frame Tie including nail Timber Frame Tie including nail Timber Frame Tie including nail

Allow for maximum height displacement of 24mm. For our full range of cavity wall ties and ancillary fixings please see

www.expamet.co.uk/expamet-powertie

12

Movement joints are necessary in masonry wall panels to cater for the natural movement of buildings. Tensile and compressive forces can develop that lead to cracking and bowing of walls. BS5628-3 details the provision of movement joints in clay, calcium silicate, concrete and stone masonry. Power-Tie Movement Ties allow expansion and contraction at movement joints whilst providing shear resistance between adjacent panels and supports. Placing the sleeve on the plain end of the movement tie with 10mm clearance, debonds the tie from the mortar joint, permitting longitudinal movement.

STAINLESS STEEL MOVEMENT TIES

Type Reference

Size (mm)

Quantity

Description

Straight Movement Tie with debonding sleeve.

SMT200 SMT225 SMT250

L:200 L:225 L:250

100 100 100

Straight Movement Ties are built into the corresponding bed joints of adjacent panels.

BMT 100 BMT 150 BMT 200

L:100 / H:50 L:150 / H:50 L:200 / H:50

100 100 100

Bent Movement Ties are mechanically fixed to adjacent supports. Slotted end provides vertical adjustment.

Bent Movement Tie with debonding sleeve.

STAINLESS STEEL SCREW-IN STARTER AND CAVITY TIES

SST

SCT

Quick and easy method to tie new walls to existing walls. Screw-in Starter and Cavity Ties are made from austenitic stainless steel to BS EN 10088-3. Supplied with masonry plug. Nominal cavity width for SCT: 50 - 100mm.

Type Reference

Length (mm)

Quantity

Description

SST130#10 SST130

130 130

10 100

Screw-in Starter Tie Screw-in Starter Tie

SCT 150 SCT 180 SCT 200 SCT 225

150 180 200 225

100 100 100 100

Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip Screw-in Cavity Tie with V Drip

13

19 8

EXPAMET SAFE EDGE FRAME CRAMPS AND SCREW-IN FRAME TIES

6 Dia Holes

10

50

100 / 150 / 200

Screw-in Frame Ties secure timber window and door frames to inner leaf of masonry.
Ref. Material Size (mm) Qty per box

BAT Safe Edge Frame Cramps provide positive location of


SIFT130RT SIFT130#10

Stainless Steel Stainless Steel

130 130

100 10 bags of 10

window and door frames to inner leaf of masonry. Manufactured from pre-galvanised steel strip with zinc

SIFT

Bright Zinc Plated Steel

150

100

coated edges to BS EN 10327:2004 : DX51D + Z275. Fixing: use 2 No 4.5mm nails or No. 8 screws, galvanised or sherardised.
Ref. SEFC150 SEFC200 SEFC250 Width 19mm 19mm 19mm Length 100mm 150mm 200mm Upstand 50mm 50mm 50mm Qty/Box 125 125 125

SIFT130

SIFT

EXPAMET SECURITY MESH

50-73HFG 50-73HF

50-89HRG 50-89HR

50-76MFG 50-76MF

(Above shown at approx 50% actual size)

A cost effective way of securing buildings or internal spaces by sandwiching a layer of steel mesh into the walls and ceilings during construction. Available in a range of gauges this high quality security mesh is suitable for internal walls, ceilings, partitions and external brickwork. It can also be provided in galvanised steel, where damp conditions are expected. See our full range of Expanded metal and lath at www.expamet.co.uk

Ref.

Description

Mesh LW 42.9 50.8* 43.4 42.9 50.8* 43.4

Mesh SW 14.2 22.6* 18.0 14.2 22.6* 18.0

Strand Strand Weight Width Thickness Kg/m2 4.6 3.1 2.3 4.6 3.1 2.3 2.7 3.0 1.1 2.7 3.0 1.1 8.59 6.52 1.85 8.59 6.52 1.85

Sheet Size

Material

50-73HFG 50-89HRG 50-76MFG 50-73HF 50-89HR 50-76MF

Security Mesh - Flattened Security Mesh - Raised Security Mesh - Flattened Security Mesh - Flattened Security Mesh - Raised Security Mesh - Flattened

2440 x 1220 2440 x 1220 1250 x 2500 2440 x 1220 2440 x 1220 1250 x 2500

Galvanised Steel to BS EN ISO 1461 Galvanised Steel to BS EN ISO 1461 Galvanised Steel to BS EN ISO 1461 Hot Rolled Mild Steel Hot Rolled Mild Steel Cold Rolled Mild Steel

* Mesh pitch size

14

26

50

FLAT WIRE REINFORCEMENT


For structural applications

Power-Tie Flat Wire Ladder Reinforcement is made from austenitic stainless steel to 1.4301 : BS EN 10088-3. Ladder length 2700mm. Conforms to BS 5628-2. 500N/mm2 minimum tensile strength. Special designs are available on request for corners and T-shapes.

Reference

Type

Main Wire Height (mm)

Equivalent Round Wire Diameter (mm)

Ladder Width (mm)

Wall Width (mm)

Qty

SBSF3060 SBSF30100 SBSF30150 SBSF30175 SBSF3560 SBSF35100 SBSF35150 SBSF35175 SBSF4060 SBSF40100 SBSF40150 SBSF40175 SBSF4560 SBSF45100 SBSF45150 SBSF45175 SBSF5060 SBSF50100 SBSF50150 SBSF50175

Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf Single Leaf

2.8 2.8 2.8 2.8 2.9 2.9 2.9 2.9 3 3 3 3 3 3 3 3 3 3 3 3

3 3 3 3 3.5 3.5 3.5 3.5 4 4 4 4 4.5 4.5 4.5 4.5 5.0 5.0 5.0 5.0

60 100 150 175 60 100 150 175 60 100 150 175 60 100 150 175 60 100 150 175

100 140/150 190/200 215 100 140/150 190/200 215 100 140/150 190/200 215 100 140/150 190/200 215 100 140/150 190/200 215

20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20

Overlap ends 225mm.

EXMET REINFORCEMENT
For non-structural applications

Stainless steel Exmet is manufactured from austenitic stainless steel 1.4301 to BS EN 10088-1. Coil length 20m. Expanded steel mesh with no joints or interweaving to fail under stress.

Ref

Material Thickness (mm)

Coil Size Width (mm)

Wall Width (mm)

Quantity

76820 76920 77020 77120

0.3 0.3 0.3 0.3

65 115 175 225

100 140 225 265

5 5 1 1

Overlap ends 75mm. 15

EXPAMET FRAMING ANCHORS


MFAAL (left handed) MFAAR MFABL (right handed) (left handed) MFABR MFAC (right handed)

BAT Multi-Grip Framing Anchors offer the most effective and


TYPE MFAAL

economical method of providing strong, mechanical joints for framing of timbers


29 26 18 29 26 18 15 40 60 55 35 10

Five types available: AL, AR, BL, BR and C. MFAAL & MFAAR: for anchoring rafters and trusses to wall plate. MFABL & MFABR: for anchoring headers to studs, beams to posts and studs to plates. MFAC: for right or left handed use for anchoring joists to beams, stringers to headers and hip joints.

127

43

Design Features
G Manufactured from 1mm thick pre-galvanised mild steel

32

26 8 33. 5

to BS EN 10327 : 2004, DX51D + Z275.

TYPE MFABL
Overall height: Width: 34mm Hole dimension: 4mm 200 no. per box
15 40 60 15 40 60

127mm

Installation Requirements
Framing anchors must always be used in pairs to minimise eccentric loading.
43

127

Recommended fixing: BAT 3.75 x 30mm long square twisted sherardised nails. Note: Use all available timber facing holes.

32

26 8 33. 5

TYPE MFAC
Safe Working Loads:
15 10 40 60 55 35

Longitudinal Loads

Types A & B: longitudinal capacity 1.3kN/pair lateral capacity 1.1kN/pair

s oad ral L Late

127

Type C: longitudinal capacity 3.7kN/pair


32 26 8 10 20 28 32 26 11 10 20 28

16

EXPAMET ANGLE PLATE


BAT Angle Plates are used as a safe and economical method of connecting joists to purlins.

Design Features
G Manufactured from 2mm thick hot dipped pre-galvanised

mild steel to BS EN 10327 : 2004, DX51D + Z275.


G Safe Working Loads:

1 pair = 3.5kN 2 pairs = 7.5kN

Ref: AP30030

300mm x 30mm x 30mm

50 per bag

Installation Requirements
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails. Use all timber facing nail holes. Minimum timber depth of 150mm. Ensure the timbers project a minimum of 50mm beyond the Angle Plates.

Steel Beam

150mm minimum

T imber packer in beam (bolted) .

17

EXPAMET ANGLE BRACKETS


BAT Angle Brackets are designed for multi-purpose fixing applications and can be used as replacement cleats, nailed or bolted.

LIGHT DUTY
Ref: AB604060 60mm x 40mm x 60mm 12 holes @ 4.5mm 100 no. per box
B
38

Design Features
G Manufactured from hot dipped pre-galvanised

mild steel to BS EN 10327 : 2004, DX51D + Z275.


G Light Duty:

AB604060 2mm thick


60 5. 5 12 25 12 5. 5 2

G Heavy Duty:

HD9090; HD15090; HD150150 2mm thick, ribbed

VIEW ON B
18.5 12 5. 5 14 11x30 14 16 6
7 11 7

Installation Requirements
Angle Brackets may be used for timber/timber, timber/steel and timber/masonry connections. May be fixed with nails, bolts or coach screws. Must be used in pairs.

12

25

12

5. 5

11 9

Nailed Safe Working Loads kN (per pair) Type


AB604060 HD9090 HD15090 HD150150

VIEW ON A

14

14

Uplift
1.2 1.6 1.4

Shear
1.8 3.6 4.6
10 7 10
9

HEAVY DUTY
VIEW ON A
17. 5 17. 5 35 10

BS 5268 Pt 2 Long term loads Nails 3.75 x 30mm long square twisted sherardised

Ref: HD9090 87mm x 87mm x 59mm 16 holes @ 4mm 50 no. per box

Uplift
11x30
9

59

Shear
22. 5 Stiffening Rib 32 17

VIEW ON B
59

11

13

42

B A
87
9

17
9

87

27 59

18

EXPAMET ANGLE BRACKETS

10 7 10

17.5

17.5

35

10

HEAVY DUTY
9

11x30

63
9

VIEW ON C

Ref: HD15090 90mm x 150mm x 63mm 20 holes @ 4mm 50 no. per box
63
10 7 10

22. 5 Stiffening Rib

32

17 11x30

22
30

C
30

51

D
150

11
17.5

VIEW ON D

42

17.5

90 (TYP)

9
35

17

9
10

90

27 63

11 6 10

25

25

30

30

29

10 9 11x30 9

HEAVY DUTY
Ref: HD150150 150mm x 150mm x 63mm 20 holes @ 4mm 40 no. per box

VIEW ON E
9

63

23

54

30

26

Stiffening Rib 24 11x30

53

150

VIEW ON F
30

F E
9

9 10 150 2 31 63

19

EXPAMET ANGLE BRACKETS


B C

Light Duty Angle Brackets


Ref AB303015 Size (mm) A x B x C 30 x 30 x 15 40 x 40 x 40 50 x 50 x 35 60 x 40 x 60 80 x 40 x 42 80 x 80 x 18 90 x 60 x 59 90 x 90 x 60 100 x 60 x 60 125 x 125 x 42 150 x 90 x 59 150 x 150 x 63 Qty 100 100 100 100 50 50 50 50 50 50 50 50

T & L Jointing Plate


Ref T1408030 Size (mm) A1 x A2 x B Qty 140 x 80 x 30 120 x 120 x 20 20 20

AB404040 AB505035 AB604060 AB804042

A2

L12012020

AB808018 AB906059 AB909060 AB1006060 AB12512542 AB1509059 AB15015063

A1 B

A2 C

Adjustable Angle Brackets


Ref AAB1403540 AAB806520 Size (mm) A x B x C 140 x 35 x 40 80 x 65 x 20 Qty 50 20

A1 A B

Flat Jointing Plate


Ref Size (mm) A x B 175 x 59 250 x 46 300 x 63 Qty 50 50 50

JP17559 JP46250 JP63300

Nail Plate Brackets


Ref NPA767676 NPA575751 Size (mm) A x B x C 76 x 76 x 76 57 x 57 x 51 Qty 50 50

A B

Angle Plates
Ref Size (mm) A x B x C 30 x 30 x 210 30 x 30 x 300 Qty 50 50 AP2103030

AP3003030

20

BAT Timber Connectors are made in accordance with the requirements of BS EN 912 : 2000 specification for connectors for timber. Safe working loads, end distances and spacing are all set out in BS 5268 Part 2.

EXPAMET TIMBER CONNECTORS

SHEAR PLATE 102

SHEAR PLATE 67

Shear Plate
Manufactured in 2 sizes: SPT67 (B2) x 150 per box and SPT102 (B3) x 50 per box Designed for use with M20 bolt. Material Specification: 67mm Manufactured from galvanised hot rolled steel to BS EN 10025. 100mm Galvanised cast iron to BS EN 1562.

Tooth Plate (Round)


Manufactured in 3 sizes: 50, 63 and 75 diameter. 200, 150 and 100 per box respectively. Available in both single and double sided, eg. ref. TCSS (C6); TCDS (C7) etc. Suitable for M12 bolt. Material Specification:

Split Ring
Manufactured in 2 sizes: SRTC64 (A3) x 100 per box and SRTC102 (A3) x 100 per box Designed for use with M12 and M20 bolts respectively. Double bevelled. Material Specification: Manufactured from galvanised hot rolled steel to BSEN10025.

Square Plate Washers


Manufactured in 1 size: SPW50 (50mm square). To suit 12mm bolt. 250 per box. Bolts are not supplied with timber connectors.

Manufactured from pre-galvanised steel to BS EN 10327 : 2004 DX51D + Z275.

Application Tools
REF
SRGT/64 SRGT/102 DT/67 DT/102

For use with timber connectors. Available to special order.


SIZE mm
64mm split ring 102mm split ring 67mm shear plate 102mm plates

TYPE
Split Ring Grooving &Dapping Tool Split Ring Grooving &Dapping Tool Shear Plate Grooving &Dapping Tool Shear Plate Grooving &Dapping Tool

BAT-U-NAIL PLATE
354 305 254

BAT-U-Nail is a plate system which enables timber structures


152

203 100 51

to be made on site or in the builders workshop, since it is nailed by hand.

Design Features
G Manufactured from 0.9mm pre-galvanised mild steel to
152 114 76 19 DIRECTION OF STIFTENING RIBS 50 .8 3. 5 12.7 4.75 1.5

BS EN 10327: 2004 : DX51D + Z275.


G Widths: 76, 114 and 152mm G Lengths: 51, 100, 152, 203, 254, 305 and 354mm. G Various quantities per box. Ref. eg. BP7651.

Installation Requirements
BAT-U-Nail plates are to be fixed on both sides of the timber. Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails Loading in the direction of the plate stiffening ribs.

345 N/nail (parallel to timber grain). 145 N/nail (perpendicular to timber grain). Plate compression value 40 N/mm width of plate. To calculate capacity of connections, the lesser of anchorage, plate compression and tension should be taken. Fix in accordance with BS 5268 : Part 2.

21

EXPAMET SPLICE PLATES

Suitable for butt jointing timbers of similar cross section.

Design Features
G Manufactured from 1.2mm thick pre-galvanised mild steel to

BS EN 10326 : 2004 S280GD + Z275.


G Available in 3 types:

L61 L80 L98

61 x 400mm long 80 x 560mm long 98 x 560mm long

up to 150mm deep joist up to 200mm deep joist up to 250mm deep joist

G 8 sets of 4 per box (32 pieces) including nails.

Installation Requirements
Joint consists of 4 pieces. All nail holes must be used. Minimum timber thickness 50mm. Can be used for:
G Replacement of rotten and decayed floor joist ends.
61mm 400mm

18 mm

L61

18 mm

G Replacement of fire damaged structural timbers. G Making good localised damage or decay in structural timber work.

L80
560mm 80mm

18 mm

Joist Depth 125 150 175 200 225 250

Splice Plate Code L61 L80 L98

Splice Plate Size (mm) 18 x 61 x 400 18 x 80 x 560 18 x 98 x 560

Resistance Moment (kNm) 1.5 1.5 1.5

Shear Capacity (kN) 13 13 13

Approx. Nails per plate 27 52 65

L98
560mm 98mm

Timber Joist

Existing Joist

22

EXPAMET FRAME CRAMP


To provide positive location and support of window from timber framing to resist wind and incidental loadings.

Design Features
G Manufactured from 0.9mm thick hot dipped galvanised

mild steel to BS EN 10327 : 2004 DX51D + Z275.


G Available in 2 sizes:

Ref. FC1 FC2

Width 76mm 76mm

Length 202mm 212mm

Upstand 40mm

Qty/Box 100 100

Installation Requirements
Fixing: use BAT 3.75 x 30mm long square twisted sheradised nails.

PLAN VIEW

SOLE PLATE ANGLES

BAT Sole Plate Angles positively locate timber sole plates to concrete floor slabs using masonry fixings as required, without penetrating the dpc.

Design Features
G Manufactured from 0.9mm thick hot dipped galvanised

mild steel to BS EN 10327 : 2004 DX51D + Z275.


G Available in 2 sizes:

Ref. SPA112 SPA162

Width 76mm 76mm

Length 112mm 162mm

Upstand 40mm 40mm

Qty/Box 100 100

Installation Requirements
BAT Sole Plate Angles may be fixed on the inside of the sole plate or alternatively fixed under the sole plate with the upstand on the outside of the sole plate. Fixing: use 3.75 x 50mm minimum length nails/masonry nails.

SECTION VIEW 23

BAT SAFEPLATE

EXPAMET JUNCTION CLIP

For protection of plumbing and electrical wiring against random nailing into studs.

Can be used instead of noggins, at wall junctions and at contact points between ceiling and walls when fitted at 300mm centres.

Design Features
G Manufactured from 1mm hot dipped galvanised

Design Features
G Manufactured from 1mm hot dipped galvanised mild

mild steel to BS EN 10327 : 2004 : DX51D + Z275. Ref: SAF1 90 x 54mm 200 per box

steel to BS EN 10327 : 2004 : DX51D + Z275. Ref: JC1 250 per box.

Installation Requirements
Use wherever services occur within 75mm of face of plasterboard or 100mm of surface of floor deck. Fixing: Tap in with hammer.

Installation Requirements
Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails or ordinary plasterboard nails.

MULTI-PURPOSE FIXING BAND


6.25 Dia 3.8 Dia 41 4 12

17 58 Pitch 29

Expamet Fixing Band is an easy-to-use coil strip designed for all types of light fixing applications.

Design Features
G Manufactured from hot dipped galvanised mild steel to

BS EN 10327 : 2004 DX51D + Z275.


G Available in 3 sizes

Ref.

Width

Thickness 0.9mm 0.7mm 0.9mm

Length 10 metre coil 10 metre coil 20 metre coil

MFBA 20mm MFBB 20mm MFBA/20 20mm

Installation Requirements
Pipe fixing, General support & Duct work Clamping, Bracing & Restraining Timber repair... Fencing, Garden Sheds etc

Fixing: use BAT 3.75 x 30mm long square twisted sherardised nails, screws or bolts. Not to be used below ground.

24

EXPAMET SOFFIT VENT MESH


The provision of eaves vents to limit condensation risk is a requirement of the Building Regulations. Expamet expanded stainless steel is used over the vents to exclude birds and insects. This mesh is an economical material for the purpose. It is readily adaptable to various eaves details, is light in weight and easy to handle on site. Coils of mesh in convenient dispensers make site work easier and avoid wastage.

Examples of Applications

75 x 50mm fixing block

Design Features
G Manufactured from stainless steel to

BS EN 10088-1 : 2005 : 1.4404.


G Approx. weight 0.370kg/m2.
Soffit board rebated to fascia board

Ref: SVM1 30m x 75mm.

Installation Requirements
Mesh fixed to soffit board prior to fixing of soffit board Mesh bent to shape required

Stainless steel nails or staples should be used for fixing the eaves vent mesh. Closed area 34%. The vent gap should be increased to 15mm or 38mm to compensate.

Mesh fixed to rear of fascia board

Mesh bent to shape required

Predrilled ventilation hole

Soffit mesh fixed along the back of fascia board

Mesh held in position by soffit board

Mesh fixed to rear of fascia prior to fixing fasci

Mesh is fixed to rafter ends, bent and returned to underside

Mesh bent to shape required and compressed to fill gap on fixing of fascia board

Fascia and soffit boards are then fixed

25

EXPAMET SCROLLED HIP IRONS


Designed to provide decorative restraint when bedding hip tiles.

Ref HIP2003 HIP2503 HIP3003 HIP3004

Material Galvanised Galvanised Galvanised Galvanised

Length x Width x Thick 200mm x 25mm x 3mm 250mm x 25mm x 3mm 300mm x 25mm x 3mm 300mm x 25mm x 4mm

Height 100mm 150mm 150mm 150mm

Height

Thick

Width Length

NAILS

Stainless Steel Annular Ring Nails


SSRN 3.35 x 50mm 1000 per box

Sherardised Nails
SN32 BAT 3.75 x 30mm twisted 1000 per box SN321 BAT 3.75 x 30mm twisted 10000 per box

GALLOWS BRACKETS

The Gallows Bracket provides a method of supporting otherwise unsupported brickwork. Manufactured from 50 x 50 x 5 angle, red oxide finish. Three sizes are available (supplied in pairs). To suit M12 Masonry Anchors - not supplied.

Depth

Height Red Oxide: MH375375 MH490375 375mm high x 375mm deep (projection from wall) 490mm high x 375mm deep (projection from wall)

26

EXPAMET WALL STARTERS, UNISTARTERS AND MULTI-STARTERS

Wall Starters
Individual products designed for specic widths of new walls
There are four flanged products in the Expamet Wall Starter range, each designed for a specific wall widths, from 60mm to 260mm thick.

Stainless Steel Ref. WS060 Plastisol Coated Galvanised Steel Ref. WGC060

Stainless Steel Ref. WS090 Plastisol Coated Galvanised Steel Ref. WGC090 For brick or block walls 100 to 115mm thick.

Stainless Steel Ref. WS120 Plastisol Coated Galvanised Steel Ref. WGC120 For brick or block walls 125 to 180mm thick.

Stainless Steel Ref. WS185 Plastisol Coated Galvanised Steel Ref. WGC185 For brick or block walls 190 to 260mm thick.

The quick, easy-to-fix way to tie-in new walls to existing walls without cutting out brickwork. Suitable for walls of up to three storeys high, ie up to 8m maximum.

For lightweight block walls 60 to 75mm thick.

Wall Starters
Ref
WS060 WS090 WS120 WS185 WGC060 WGC090 WGC120 WGC 185

UniStarters
Type
Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie Single Flange Integral Tie

Description
Stainless Steel Stainless Steel Stainless Steel Stainless Steel Plastisol Coated Galv Plastisol Coated Galv Plastisol Coated Galv Plastisol Coated Galv

Wall Thickness
60 - 75mm 100 - 115mm 125 - 180mm 190 - 260mm 60 - 75mm 100 - 115mm 125 - 180mm 190 - 260mm

The universal wallstarter for any wall


The flat flange-free design of Expamet UniStarters means they can be used to construct any wall between 75mm and 250mm thick one product, multiple applications.

UniStarters
UWSS UWGC Stainless Steel Plastisol Coated Galv No Flange Integral Tie No Flange Integral Tie Up to 250mm Up to 250mm

Multi-Starters
MSSS MSGC MSGFIX MSGFIX Stainless Steel Plastisol Coated Galv Plastisol Coated Galv Stainless Steel No Flange Turn-n-slide Ties No Flange Turn-n-slide Ties Extra Fixing Pack Extra Fixing Pack Up to 250mm Up to 250mm

Contains 10 ties, 5 screws, plugs & washers

Stainless Steel Ref. UWSS

All Wall Starters, Unistarters and Multistarters are supplied with the necessary fixings.

Plastisol Coated Galvanised Steel Ref. UWGC

27

EXPAMET WALL STARTERS & UNISTARTERS FIXING INSTRUCTIONS

WALL STARTERS
CAVITY WALLS Brick & Block The left hand Wall Starter is fixed with its ties extending upwards ready for bending down into the mortar courses. The right hand Wall Starter is

Wall Starter & UniStarter Installation


G Suitable for both metric and imperial brick/block sizes. G Integral ties are designed to tie into every (225mm deep) block

inverted and fixed with the ties extending downwards.

course or every third course of (75mm deep) bricks.


They must then be bent upwards ready for setting into the mortar course as the wall is built.
G Each pack contains two 1175mm lengths. Slotted holes at each end

allow easy connection of one length to the next.

UNISTARTERS
CAVITY WALLS Brick & Block UniStarters are fixed with their ties extending upwards ready for bending down into the mortar courses. The right hand UniStarter is higher to allow the tie to bed into the first blockwork mortar course.

G Full fixing instructions and all necessary coach screws, washers

and plugs are provided. Only 5 fixings are needed for the two lengths (Type 120 and 185 Wall Starters are supplied with 10 fixings). The only tools you need are: spirit level, drill (with 10mm masonry bit) and 10mm spanner.
G Miscoursing of up to 50mm can be solved by simply bending

integral ties to suit. This will reduce the length of built-in tie, but it still meets relevant test criteria.
G All products are designed to allow up to 10mm vertical movement. G If the upper end of the product extends past the top line of your

wall, use tin-snips or a hacksaw to cut off the excess and attach
Tie-l ine
Tie-lin e

using the remaining top fixing hole.


G Align the centreline of the UniStarter with the centre of the new

wall. Align the flanged edge of the Wall Starter to the front or back
ine Tie-l
Tie-lin e

of the new wall.


G For cavity walls, each leaf will require a separate starter. G All external walls require a 10mm wide weather seal to be fitted

The distance between the flanges sets the cavity width.

Dimension to suit centralising of UniStarters in leaves of new wall.

between the product and the existing wall or applied to the raked-out vertical joint.
G In exposed locations (or to meet Local Authority specifications),

a vertical DPC should be cut into the existing wall prior to fixing
fixing points 675 either hole may be used joining adjacent Wall Starters, and UniStarters

the product.

450

slot

flat slot 25

675 either hole may be used

450

drill, plug and fix using fixings supplied

28

EXPAMET MULTI-STARTERS

Multi-Starters
Featuring a turn-n-slide tie to accommodate all sizes of brick/block.
The Multi-Starter is suitable for all wall widths from 60mm-250mm.

Installation
G The turn-n-slide ties enable the starter to be tied into any course

the builder wishes, ideally every (225mm deep) block course or every third course of (75mm deep) bricks.
G Each pack contains two 1165mm lengths. Slots at each end allow

easy connection of one length to the next.


G For more information see Wall Starter & UniStarter installation
Stainless Steel Ref. MSSS Plastisol Coated Galvanised Steel Ref. MSGC

details on previous page.

Fixing Details
Insert Turn
(anti-clockwise)

Slide

Fixing points

Joining adjacent Multi-Starters

675

450

For Masonry Movement Joint applications use Expamet Movement Ties.

675 Drill, plug and fix using fixings supplied

450

PLUMB
Ensure existing wall is sound and clean. Locate the starter above the DPC. Plumb the section and mark positions of the fixing holes.

DRILL
Drill and plug the existing wall, taking care to avoid mortar joints.

FIX
Lightly screw the first length to the existing wall over weatherseal if required, then plumb, mark and drill out the next starter. Make sure that the slot at the end of one length always lies on top of the slot of the adjacent length. Tighten all screws when all required lengths are in position.

BUILD
Lay bricks or blocks, be sure to bed them with mortar against the starter. Multi-Starter: Turn-n-slide ties into the mortar as you build. Wall Starters and UniStarters: Bend ties into the mortar as you build. Seal vertical joint with proprietary flexible sealant.

29

CONSTRUCTION FIXINGS HEALTH AND SAFETY DATA SHEET

8. EXPOSURE CONTROLS
Wear personal protection such as gloves and safety goggles when handling products. Some products may have a film of soluble cutting fluid after manufacture; therefore carry out personal hygiene, including proper washing of hands, after contact.

1. IDENTIFICATION
Expamet Construction Fixings Expamet Building Products Limited Greatham Street Longhill Industrial Estate (North) Hartlepool TS25 1PR Tel: +44 (0)1429 866688 Fax: +44 (0)1429 866633

9. PHYSICAL AND CHEMICAL PROPERTIES


Construction Fixings are supplied in various lengths, widths and gauges. Metallic grey appearance.

10. STABILITY AND REACTIVITY


Construction Fixings are stable under normal conditions but if subjected to high temperatures, fumes are produced.

2. HAZARDS IDENTIFICATION
Possible cuts from steel edges. Toxic and irritant fumes from high temperatures.

11. TOXICOLOGICAL INFORMATION 3. COMPOSITION


Galvanised steel DX51D+Z275 to BS EN 10327: 2004 DX51D+Z600 to BS EN 10327: 2004 S280GD+Z275 to BS EN 10326: 2004 Stainless steel 1.4301 to BS EN 10088-1: 2005 High temperatures can produce fumes.

12. ECOLOGICAL INFORMATION


No known hazard.

13. DISPOSAL CONSIDERATIONS


Recycle or dispose of in accordance with Waste Management Licensing Regulations.

4. FIRST AID MEASURES


Skin and eye contact: treat cuts from steel edges as required. Ingestion: not applicable. Inhalation: remove from source of fumes and dust.

14. TRANSPORT INFORMATION


Not classified as hazardous for transport.

15. REGULATORY INFORMATION 5. FIRE FIGHTING MEASURES


Non-flammable material. Construction Fixings are articles and have no obligations under REACH.

6. ACCIDENTAL RELEASE MEASURES


Not applicable.

16. OTHER INFORMATION


All products must be installed in accordance with Expamet Building Products published instructions. Where structural products are to be removed from an existing installation, care must be taken to ensure that the procedure does not compromise the loading/installation restrictions applicable to the products. The Construction Fixings Health and Safety Data Sheet is not a product specification guide.

7. HANDLING AND STORAGE


Bands and straps must not be used for lifting. Use suitable PPE when handling the Construction Fixings. Assess manual handling risks before lifting. Construction Fixings should be stacked on firm level ground in dry conditions.

Any arrangement of construction fixings shown in this brochure is indicative only. Actual fixing installations must comply with current Health and Safety requirements.

30

QUALITY YOU CAN TRUST


Expamet are not only industry leaders in the UK, but we also operate in continental Europe and the Middle East, giving us a strong continental presence. You can be assured that wherever you are you can source a range of Expamet building products.

EXTENSIVE PRODUCT RANGE


Expamet Building Products Limited is the parent company of a number of great brands with each brand committed to quality in its particular product field.

Expamet Construction - One stop shop for metalwork for the construction industry BAT Builders metalwork products Expamet Plasterers accessories Hy-Rib Permanent formwork for concrete Power-Tie Wall ties and ancillary fixings Expamet Express Our new next-day delivery service

Order before 1pm and we will despatch your order for next working day delivery, direct to branch or site. See www.expamet.co.uk for full details

TECHNICAL AND SALES SUPPORT


Expamet provide a comprehensive pre and post-sales support service. From product advice and training through to design and implementation. Our sales and technical support teams have a wealth of construction and engineering experience and are available for both on and off-site support.

For more information call us on +44 (0)1429 866655.

Expamet operate a continuous development programme and we reserve the right to amend specification without prior notification. Please note, some products are not manufactured by Expamet and are therefore excluded from registration to BS EN 9001: 2008. Please contact the technical department for further information. All copyright, trade marks and unregistered design rights for the products detailed in this brochure are the property of Expamet Building Products Ltd.

EXPAMET BUILDING PRODUCTS LIMITED UK SALES AND DISTRIBUTION CENTRE Greatham Street, Longhill Industrial Estate (North), Hartlepool TS25 1PR England Tel: Sales: +44 (0)1429 866611 Sales Fax: +44 (0)1429 866622 E-mail: sales@expamet.net General: +44 (0)1429 866688 Fax: +44 (0)1429 866633 Technical: +44 (0)1429 866655 Tech E-mail: technical@expamet.net Website: www.expamet.co.uk IRISH SALES OFFICE DUBLIN: Unit 7, Swords Business Park, Swords, Co. Dublin Tel: +353 (0) 1890 2392 Fax: +353 (0) 1890 2220 E-mail: expamet@eircom.net

Quality Assurance BS EN ISO 9001:2008 and ISO 14001 2004 Registered Firms Certificate No. FM36694, EMS 45225

You might also like