Professional Documents
Culture Documents
Fins/PVC Filling : 18 upto 250 RT 24 more than 300 Rt Types of Cooling Tower 1 Natural Cooling Tower 2. Mechanical (a) Induced draft (Counter Flow & Cross Flow) (b) Forced Draft.
Way of Best Choice of Cooling tower 1. Capacity a) Cooling Capacity in RT b) Heat Load in Kcal/Hr c) Circulation water flow rate 2. Overall Dimension a) Width(W) b) Length (L) c) Overall height(H) d) Height 3. Fan Assembly a) Diameter b) Fan speed
c) Air flow m3/h d) Motor rated output 4. Piping Diameter a) Hot water inlet hole b) Cold water outlet hole c) Drain pipe d) Overflow pipe e) Manual make-up water inlet pipe f) Automatic makeup water inlet pipe 5. Make Up a) Evaporation loss % 0.87 b) Drift loss % 0.01 6. Weight a) Dead weight b) Operating weight : almost double of dead weight. 7. Number of Cell NB: 1. Total pump head required for cooling tower circulation pump is the sum of condenser water pressure drop, piping friction loss and tower head. 2. Nominal Tons are defined as 13 Ltr/min/Ton (3.43 US ,GPM/Ton), Cooled from 37 deg C to 32 deg C with 27 deg C wet bulb temperature.
drop are achieved through engineered flute/microstructure design and the highest manufacturing standards.
1. Bonded edge with dedicated bond points for added durability. 2. Engineered microstructure for improved water distribution and thermal mixing. 3. High thermal performance. 4. Improved water distribution. 5. Square pack that efficiently direct water to both sides of sheet. 6. It is designed according to the water quality.
General Brochure
SL No. Property Unit Typical Value 1 Specific Gravity gm./cu.cm 1.45 max 2 Tensile Strength psi 6000 min 3 Flexural Strength psi 11000 min 4 Elastic Modulus psi 360000 min 5 Heat Deflection oF(264 psi) 160 min 6 Flame Speed rating Less than 5
Surface Area Model ft2/ft3 (m2/m3) ART-H 57 48 (157.5) ART-H 37 48 (157.5) ART-X 37 51 (167.4)
Dimension Sheet Spacing Flute mm Angle 19 19 19 300 300 N/A Sheets per Height ft (mm) 20 20 16 Length (mm) Width (mm) 12'' (305) 12'' (305) 12'' (305)
6.5'' ( 165) 57''(1450) 6.5'' ( 165) 37'' (940) 72" (1829) 37'' (940)
Sprinkler Head Our Cooling Tower Sprinkler Head has its own unique features:
1. Special design to rotate in 5-7 rpm, which gives good thermal performance.
2. Durable, robust sprinkler head is ready for working in very bad quality water 3. Die-casted Aluminum 4. Light weight
General Brochure
Base Pipe Dia: 1.5 inches, 40 NB Distribution Pipe Dia: inches, 20 NB No. of Distribution Point: 4 MOC: Aluminum Threaded End Product Code: PC03007
Base Pipe Dia: 2 inches, 50 NB Distribution Pipe Dia: 1 inches, 25 NB No. of Distribution Point: 4 MOC: Aluminum Threaded End Product Code: PC03008
Base Pipe Dia: 2.5 inches, 65 NB Distribution Pipe Dia: 1 inches, 25 NB No. of Distribution Point: 4 MOC: Aluminum Threaded End Product Code: PC03009
Base Pipe Dia: 3 inches, 75 NB Distribution Pipe Dia: 1.5 inches, 20 NB No. of Distribution Point: 4 MOC: Aluminum Threaded End Product Code: PC03010
Base Pipe Dia: 4 inches, 100 NB Distribution Pipe Dia: 2 inches, 50 NB No. of Distribution Point: 4 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03011
Base Pipe Dia: 4 inches, 100 NB Distribution Pipe Dia: 1.5 inches, 40 NB No. of Distribution Point: 6 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03012
Base Pipe Dia: 5 inches, 125 NB Distribution Pipe Dia: 2 inches, 50 NB No. of Distribution Point: 4 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03013
Base Pipe Dia: 6 inches, 150 NB Distribution Pipe Dia: 3 inches, 75 NB No. of Distribution Point: 4 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03014
Base Pipe Dia: 8 inches, 200 NB Distribution Pipe Dia: 3 inches, 75 NB No. of Distribution Point: 6 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03015
Base Pipe Dia: 10 inches, 250 NB Distribution Pipe Dia: 3 inches, 75 NB No. of Distribution Point: 8 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03017
Base Pipe Dia: 12 inches, 300 NB Distribution Pipe Dia: 3 inches, 75 NB No. of Distribution Point: 10 MOC: Aluminum SS Nut & Bolt, Teflon Oil Sealed Bearing Product Code: PC03018
General Brochure
Tip to tip Distance:2950mm (116 inch) Hub Dia:360mm (14 inch) Blade Length: 1070mm (51 inch) SS Clamp with SS Nut & Bolt Product Code: PC03019 Tip to tip Distance:2470mm (97 inch) Hub Dia:330mm (13 inch) Blade Length: 1070mm (42 inch) SS Clamp with SS Nut & Bolt Product Code: PC03020 Tip to tip Distance:2325mm (91.5 inch) Hub Dia:330mm (13 inch) Blade Length: 990mm (39 inch) SS Clamp with SS Nut & Bolt Product Code: PC03021 Tip to tip Distance:2210mm (87 inch) Hub Dia:330mm (13 inch) Blade Length: 940mm (37 inch) SS Clamp with SS Nut & Bolt Product Code: PC03022 Tip to tip Distance:1880mm (74 inch) Hub Dia:305mm (12 inch) Blade Length: 790mm (31 inch) SS Clamp with SS Nut & Bolt Product Code: PC03023 Tip to tip Distance:1780mm (70 inch) Hub Dia:305mm (12 inch) Blade Length: 740mm (29 inch) SS Clamp with SS Nut & Bolt Product Code: PC03024 Tip to tip Distance:1480mm (58 inch) Hub Dia:305mm (12 inch) Blade Length: 590mm (23 inch) SS Clamp with SS Nut & Bolt Product Code: PC03025
Tip to tip Distance:920mm (36 inch) Hub Dia:105mm (4 inch) Blade Length: 410mm (16 inch) SS Nut & Bolt Product Code: PC03026 Tip to tip Distance:610mm (24 inch) Hub Dia:105mm (4 inch) Blade Length: 250mm (10 inch) SS Nut & Bolt Product Code: PC03027 Tip to tip Distance:440mm (17 inch) Hub Dia:80mm (3 inch) Blade Length: 175mm (7inch) SS Nut & Bolt Product Code: PC03028
Cooling-tower-motor
General Brochure
Power rating: 0.75 Kw 1440 rpm TEFC, Insulation Class-F, IP-55 V-440, CI Body PC03001
FRP chemical:
1) Resin Product Code: PC01001 2) Hardener Product Code: PC01002 3) Fibre-glass Product Code: PC01003
User Manuals
Electric Blackout. Fuse Burn Out. Contact Power Co. 2 Get Proper Fuse. Insufficient Switch Capacity. Bad Switch Change the Proper Switch. Adjust Contact. Contact. Bad Star-Delta Contact. Too Heavy Loads. Lowering of Voltage. Bad Bearing. Adjusts Contact. Lighten to Proper Load. Consult Power Company. Exchange Bearing.
Temperature Rise Motor Temp. Rise. Too Heavy Load. Lowering of Voltage. Lighten Load to Proper Level. Consult Power Company. Send High Surrounding. Out to Repair Shop.
Rise in Water Temperature Water Flow Above Specified Flow. Air Flow Below Specified Flow. Load Higher than Design. Fills Chocked or coated. Correct Flow Rate. Adjust Blade Angles Check and Clean Jali. Adjust Load to correct Flow Rate. Clean/Replace Fills. Use Proper Water Quality (Make Up)
Fresh Air Intake not sufficient or area sufficient or area Improve Ventilation and Ensure Exhaust air near tower not as specified. does not get recycled.
Water Bypassing Fills. Sprinkler Jammed/Water not being Sprinkled and Distributed.
Check Sprinkler Head and Pipe Leakages. Repair Sprinkler and Distribution System.
Water Flow Less Filters Chocked Sprinkler Pipe Chocked Level of Water Low in sump Pump Small Clean Water Filters Clean Pipes and Holes Adjust Float/Inlet Flow Proper Make-up Replace to Correct Flow Volume
Air Flow Low Fan Speed Low Fan Blade Angle Incorrect Inlet Jali Chocked Check Bearing/Motor Correct Blade Angle to Required Setting Clean Air Path
Noise & Vibration Fan Mounting Loose Tighten Mounting Bolts and Correct/Replace if needed. Tighten Blade in Hub Rebalance and Adjust Check and Grease or Replace Bearing on Motor Tighten and use end Plate and shims if required
Fan Blocks Loose Fan Unbalanced Motor Bearing Faulty Hub Mounting on Motor Shaft Loose
Many Parts Rubbing againt Tower Component Give Proper Clearance and Adjust/Align Components.
Water Carry Over Sprinkler Rotation too Fast Adjust Sprinkler Angles as to MAtch the specified rotation Clean up any blockage part Renew Eliminator Adjust as specified below 25 M.M. FT 8 TO FT-30 50 M.M. FT-40 TO FT-80 75 MM. FT-100 AND UP
Vibrations Are Normal/Noise Normal. Water Distribution Proper. Fan Motor Current Normal. Inlet/Outlet Temperature Of Water Normal.
Every Week:
Clean Inlet Jali To Remove Entrained Matter. Clean Inlet Water Filter. Clean Sprinkler / Nozzles If Chocked. Check Growth of Alger Etc. And Remove From Sump.
Every Month:
Drain Tank, Flush Out and Remove Any Sediment. Check Fills If Clogged Due To Algae, Sediment / Salts, Etc. Check Structure / Frp Casing and Basin Damage and Repaired If Necessary. Clean From Outside With Soap and Water. Check And Tight All Bolts. Smear Bolts with Grease to Facilitate Easy Opening the Next Time.
Grease All Bearings Of Motors. Grease All Bearings Of Sprinklers. Check Run out On Fan Motor Shaft.
Clean Blades Of Foreign Matter. Check Fills If Damaged And Replace. Enlace Bearing Of Sprinkler Assembly After 2 Years And Fill With Grease.