You are on page 1of 106

Sl.No.

1 2 3 4 5 6 7

BOQ Structural Items (A,B,D,G block) Structural Items (E block) Structural Items (Fblock) Civil Works - Main block (A,B,D) Civil Works - E block Civil Works - F block Civil Works - G block

Amount (INR)

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G07

SUMMARY OF BILL OF QUANTITIES FOR STRUCTURAL WORKS MAIN BLOCK (A,B,D, G BUILDING)

NO.

DESCRIPTION

A B C D E F G H I J K

EXCAVATION BACKFILLING PLUM CONCRETE PLAIN CEMENT CONCRETE REINFORCED CEMENT CONCRETE SHUTTERING, FORMWORK & STAGING REINFORCEMENT STRUCTURAL STEEL EXPANSION JOINT GROUTING COATINGS AND PAINTS OVER STRUCTURAL MEMBERS BRICKWORK AND RUBBLE WORK FOR STRUCTURAL PURPOSES SLEEVES PRE-STRESSING TO CONCRETE GRAND TOTAL (A to N)

L M N

( Rupees

Only )

TENDERER

SUMMARY - Page 2 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

WORKS

AMOUNT
(In rupees)

Only )

TENDERER

SUMMARY - Page 3 of 106

CLIENT

HLL CAMPUS AT ANDHERI - BOQ FOR STRUCTURAL ITEMS


Section S.No. A 1 ITEM DESCRIPTION EXCAVATION AND EARTH WORK Excavation ( By mechanical & manual means ) :- All excavation Carrying out excavation in the specified type of soil, inclusive of de-watering to keep the area clear from water ponding at all times, to the required depth and profile as shown on drawings. The final layer of 300mm thickness shall be manually excavated. The unsuitable excavated earth, as directed by Project Manager, shall be carted away from the site and disposed in the approved dump yard of the local authority, by the contractor.The rate of excavation includes cost of all necessary licences and permis Contractor shall take all necessry steps to ensure that the temporary soil retention system (touching piles, diaphragm wall or any other shoring system) is not damaged or disturbed during the excavation activity. In case any damages occurred, the Contract The final approved founding strata shall be left absolutely clean by removing loose, slushy soil, murrum and weathered rocks with necessary tools & tackles, cleaning the surface by wire brush and carting away the debris, dewatering to keep site dry at all Mode of measurement for excavation carried out by Mechanical Appliances using various attachments such as bucket or rock breaker or chiesel shall be measured and paid as per IS 1200 Part -27. In case of excavation carried out by manual means the measureme Carrying out excavation in the specified type of soil, up to any lead and level, inclusive of dewatering to keep the area clear from water ponding till the time shoring, protecting the slopes/sides etc. is complete. The excavated earth (excluding a certain quantity of boulders and hard rock of size 600 mm and above, which is to be stacked properly within the site at the specified location) shall be carted away by the contractor. Contractor shall hand over the site as a whole or in phases as directed by the Engineer in Charge after removing soft soil, slush, mud, loose material, stone chips, from rock surface or any other founding strata, which is approved as the final block excav Excavation in all type soil for foundations,plinth beams,swimming pool,water tank,STP,compound wall foundation,trenches,etc. Trimming the vertical / inclined / horizontal soil of any type / weathered rock surfaces of already excavated pits of any size, for accommodating the required sizes and shapes of RCC members and other civil work items as shown in the drawings and describ SUB-TOTAL UNIT QUANTITY UNIT RATE AMOUNT

II

III

IV

VI

VII

VIII

1.4

Cu.m

1,346

1.5

Cu.m

2,426

Section S.No. 2 2.1 2.2

ITEM DESCRIPTION BACKFILLING Backfilling with earth available at site Backfilling with earth brought from outside. The earth brought from outside shall be good quality murrum approved by Engineer in Charge. Filling with dry sand above raft as counterweight, for attaining the required levels in the lift pits and other pits as mentioned on drawings Filling in plinth or above RCC slab to make up the required level with good quality murrum SUB-TOTAL PLUM CONCRETE Providing and laying plum concrete course in plain cement concrete M:15 and evenly distributed plums of basalt or trap of size 160 mm and above up to any reasonable size to a maximum limit of 30% by volume of concrete including mechanically vibrating, co Filling in pits, excavated pits, in pockets of strata after removal of soft soil / weathered rock at founding level to level the surface before carrying out levelling PCC As counterweight over basement raft, using shuttering and formwork wherever necessary to create sumps, drains, slopes etc. In mass concreting for filling in lift pits, sumps, creating ramps etc. On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s SUB-TOTAL PLAIN CEMENT CONCRETE Providing and laying plain cement concrete M:15 including centering, vibrating, shuttering, compacting, curing, de-watering etc. complete. Below waterproofing layer, raft, foundations and plinth beams as levelling course In flooring above compacted dry sand filling / plum concrete filling/ rubble soling or compacted plinth filling, to a thickness of 150 mm to 300 mm after laying reinforcement if specified, the reinforcement work being paid for separately under the reinfor In mass concrete with or without formwork exceeding dimensions 1.0 m in at least one direction On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s

UNIT

QUANTITY

UNIT RATE

AMOUNT

Cu.m Cu.m

15,816 3,954

2.3

Cu.m.

200

2.4

Cu.m

2,610

B.

1.1

Cu.m.

205

1.2 1.3

Cu.m. Cu.m.

13,463 205

1.4

Cu.m.

200

C.

1 1.1

Cu.m.

1,762

1.2

Cu.m.

133

1.3

Cu.m.

105

1.4

Cu.m.

25

Section S.No. SUB-TOTAL D.

ITEM DESCRIPTION

UNIT

QUANTITY

UNIT RATE

AMOUNT

REINFORCED CEMENT CONCRETE


Providing and laying premixed and transported to site, pumped / lifted at the location of pour with the contractors own arrangement , controlled reinforced cement concrete conforming to grade M: 40 (IS 4562000) with minimum cement content 360 kg/cum as The rate shall include for providing recesses to slabs, walls and columns and placing and securing properly within the form-work sleeves and/or openings in slabs, embodiments such as bolts, insert plates, corner protection angles, plates, anchors etc. (em The rates shall also account for any admixtures (approved by the consultants) the contractor may use in order to enhance the workability, to achieve accelerated strength, etc. The rate shall include use of plasticizers and retarders to limit the water/cem

Cu.m.

29,910

II

SUB-TOTAL
2 Shuttering , Formwork and Staging Formwork/Shuttering- designing,obtaining approval of design for structural stability and method statement from Project Manager and Structural Consultant prior to commencement of the specific item well in advance, providing, erecting, fabricating, tying, f The rate shall include for providing recesses, cornices and ledges to slabs, beams, columns, walls, providing openings in slabs, walls, beams, making provisions for fixing inserts, sleeves etc. in concrete, making holes in form-work for taking out dowels The rate shall be separately quoted for the following :

0.1

Basement raft, Bottom raft of water tanks, Reinforced floor laid over subgrade/PCC levelling course/Plinth filling/Plum Concrete or Waterproofing layer, to be laid in panels of predetermined dimensions having approved construction joints. Isolated, combined or strip foundations or pilecaps for columns, shear walls and lift walls (projections above raft in case of footings or pilecaps monolithic with the raft, and full volume of the footings or pilecaps in case of isolated or combined footi Machine foundations and mass concreting

Sqm

0.2

Sqm

5,472

0.3

Sqm

75

Section S.No. 2

ITEM DESCRIPTION Walls and Retaining Walls Parallel faced or tapered retaining walls for basement, swimming pool, underground and above-ground tanks, trenches, gutters, drains etc. Shear walls and lift walls of any thickness and any shape in plan with straight faces. Retaining wall below compound wall to achieve level difference between adjoining plots/areas. Columns Columns may be free standing or integrated with shear / lift walls, they may be floating on or hanging from beams. Rectangular, T shaped, L shaped or square columns, pedestals and stub columns, buttresses for retaining walls. Circular or oval columns, pedestals and stub columns. Columns, pedestals and stub columns of any other shapes with straight faces Columns inclined in elevation

UNIT

QUANTITY

UNIT RATE

AMOUNT

2.1

Sqm

13,152

2.2 2.3 3

Sqm Sqm

9,272 400

3.1

Sqm

19,233

3.2

Sqm

185

3.3 3.4

Sqm Sqm

360 360

Beams Beams include simply supported, continuous, cantilevers and may be spaced at any distance, may or may not be integrated with RCC/Steel beams. Beams straight in plan & elevation, including ribs of ribbed floor Beams curved in plan Brackets and ledges from columns, walls, beams etc Lintels precast or cast in situ (rate to include erection of precast lintels) RCC transfer girders carrying flooting columns,more than 400 mm in width and 2000 mm in depth.

4.1 4.2 4.3

Sqm Sqm Sqm

18,086 1,684 60

4.4

Sqm

365

4.5

Sqm

350

Slabs Horizontal slabs integrated with concrete beams, ribs, structural steel beams or truss / girder members, or flat slabs with or without drop panels, (drop panel being measured as slab with its own thickness). 100 mm thick 125 mm thick 150 mm thick 175 mm thick Sqm Sqm Sqm Sqm 45 45 2,281 17

5.1

a. b. c. d.

Section S.No. e. f. g. h. i. j. 200 mm thick 225 mm thick 250 mm thick 275 mm thick 300 mm thick

ITEM DESCRIPTION

UNIT Sqm Sqm Sqm Sqm Sqm Sqm

QUANTITY 4,161 65 38,089 528 914 25

UNIT RATE

AMOUNT

Above 300 upto 400 mm thickness Extra over 5.1 for any thickness for providing slope up to 1 in 10 to slab to its bottom and/or to its top Extra over 5.1 for any thickness for providing slope between 1 in 5 and 1 in 10" to slab to its bottom and/or to its top Chajjas, ledges of thickness 75 mm to 150 mm, horizontal or sloping, upto 900 mm cantilever projection Chajjas, ledges of thickness more than 150 and upto 175 mm, horizontal or sloping upto 900 mm cantilever projection
Chajjas, ledges of thickness more than 175 and upto 250 mm, horizontal or sloping upto 2000 mm cantilever projection .

5.2

Sqm

60

5.3

Sqm

5.4

Sqm

40

5.5

Sqm

40

5.6

Sq.m

760

Staircases Staircase including waist slab and steps. Midlanding slab will be measured in this item. Pardis will be measulred under item 7 below. Pardis, drop pardis and parapets Vertical, sloping and upstand pardis, drop pardis, parapets of thickness up to 200 mm. Vertical, sloping pardis and drop pardis above 200 mm thickness Parapets in concrete block above 200 mm thickness Coping over parapets Precast Reinforced Concrete Members Extra over D.4 to D.7 including sub-items described therein, for pre-casting the RCC members using specified class of surface finish in respective items, with necessary anchorage projections or recesses as per drawings and details, lifting, placing and gr Making Pre-cast curb blocks, parapets, dividers, fencing posts, paving slabs, sump and manhole covers etc., lifting, transporting to any lead, and placing them at any height in position, grouting complete. Maximum weight of such pre-cast member shall be 2 Closing the openings Sqm

6.1

Sqm

2,538

7 7.1

7.2

Sqm

7.3 7.4 8

Sqm Sqm

8.1

Sqm

8.2

Sqm

Section S.No.

ITEM DESCRIPTION Concreting slabs in the openings and holes after installation of services, taking due care not to damage or disturb the installations, by providing shuttering and staging around the existing pipes, ducts etc. This item is valid for openings shown on the c

UNIT

QUANTITY

UNIT RATE

AMOUNT

9.1

Sq.m

E.

DEVIATION IN CONCRETE GRADE, MIX AND RENDERING 1 1.1 1.2 2 2.1 2.2 2.3 2.4 Extra over item D for providing in place of M:40 mix M:50 mix with approved design M:60 mix with approved design Reduction in rate of item D for providing in place of M:40 mix M:35 mix with approved design M:30 mix with approved design M:25 mix with approved design M:20 mix with approved design

Cu.m Cu.m

Cu.m Cu.m Cu.m Cu.m

F.

SPECIAL STAGING, FORMWORK & PROPPING Extra over item no. D.1 to D.8 including their sub items and deviation in rates for suspended floor slabs, roof slabs, balcony slabs using preengineered shuttering supported on structural steel beams, trussed beams and/or plate girders without taking any Extra over item no. D.1 to D.8 including their sub items and deviation in rates for supporting slabs and beams requiring staging heights more than 4.5 m from floor to floor for every 1.0 m increase as described below. The rate is for the concrete volume s This item is not valid for the staging to be erected at the lower basement level for supporting the shuttering of the upper basement (B1 level) slab. It may be noted that if plum concrete filling is carried out immediately after casting B2 level raft, the More than 4.5 m upto 5.5 m More than 5.5 m upto 6.5 m More than 6.5 m upto 7.5 m More than 7.5 m upto 8.5 m More than 8.5 m upto 9.5 m SUB-TOTAL REINFORCEMENT Providing and fixing steel reinforcement for RCC including material, fabricating as per IS 2502, transporting, storing, de-coiling, straightening, cutting, bending, spirally hooping and placing in position at all levels, including all labour, equipments, The quoted rate will include welding of reinforcement with low hydrogen low heat welding electrodes for the welding length mentioned in the drawings in place of conventional laps, wherever consultants recommend, for which no extra shall be claimed. Replac

II

III

1.1 1.2 1.3 1.4 1.5

Cu.m Cu.m Cu.m Cu.m Cu.m

G.

II

Section S.No.

ITEM DESCRIPTION

UNIT

QUANTITY

UNIT RATE

AMOUNT

III

1 2

The rate also includes protecting the reinforcing bars in their virgin form or in the fabricated form, or when placed and tied up in position or as dowels left for future continuation of work or at construction joint against corrosion due to exposure High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 500 N/sq.mm High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 415 N/sq.mm

3,263

Providing, fixing, aligning threaded tapered couplers for reinforcement wherever specified in the drawings for continuation / splicing of bars as recommended by the manufacturers. The item includes machining the reinforcing bars to match the threads of th 16 mm dia or reduction coupler 16/12mm 20 mm dia or reduction coupler 20/16mm 25 mm dia or reduction coupler 25/20mm 32 mm dia or reduction coupler 32/25mm 36 mm dia or reduction coupler 36/32mm 40 mm dia or reduction coupler 40/36mm SUB-TOTAL STRUCTURAL ERECTION STEEL FABRICATION AND Nos. Nos. Nos. Nos. Nos. Nos.

2.1 2.2 2.3 2.4 2.5 2.6

Fabrication from local structural steel plates and sections Preparing shop drawings, obtaining Structural consultants approval, supplying, fabricating in accordance with IS:800, delivering at site, hoisting M.Tons and fixing in position, including all temporary staging and supporting work and making all structural steel

75

Fabricating columns, beams, joists, struts, built up ties and bracings, staircases, tressles, platforms, lofts, catwalks, walkways, bridges, ladders, brackets, suspended canopy etc.and other steel members and items out of the following readily available s a b c d e f I and H sections of any size Channels of any size Angles of any size Hollow rectangular or square sections Hollow circular tubes Plates

Supplying, fabricating and installing inserts in concrete in the form of mild steel angles, flats, plates, holding down bolts, angle frames, etc. with M.Tons anchors in the form of rods or flats including welding anchors, lifting hooks, rungs, templates etc., al Supplying and fixing expandable anchor bolts in concrete or masonry including drilling, cleaning the holes, ramming the bolts in the holes in accordance with manufacturers procedures, recommendations and specifications for fixing plates or other steel me

31

Section S.No. 4.1 4.2 4.3 4.4 4.5

ITEM DESCRIPTION 10 mm core diameter 12 mm core diameter 16 mm core diameter 20 mm core diameter 25 mm core diameter Supplying, cutting to shape, securing to the supporting members with bolts or welding as shown on drawings, M.S.Chequered plate. The rate shall be for the actually placed plate and not for the procured quantity. 6 mm thick 8 mm thick SUB-TOTAL EXPANSION JOINTS Providing expansion joint between structural members by fixing 50 mm thick asphalt impregnated soft board on one surface to serve as shuttering and finishing the expansion joint neatly as per detailed drawing. Sealing the expansion joint with 50 mm x 32 mm approved quality polymer based silicone sealant from external as well as internal side as per manufacturers requirement . Providing and laying aluminium flashing 0.5 mm thk bent to shape over expansion joint, fixed to the concrete surface on one side of the expansion joint as shown in the structural drawings. SUB-TOTAL

UNIT Nos. Nos. Nos. Nos. Nos.

QUANTITY

UNIT RATE

AMOUNT

5.1 5.1

Sq.m Sq.m

I.

Sq.m

R.M.

R.M.

J.

GROUTING Providing and grouting with polymer mixed cementatious low viscous grout of minimum strength of 40 N/sq.mm (that of the parent reinforced concrete member) as per manufacturers recommendations of approved quality and brand Under the bases and in the pockets left for the foundation bolts of structural steel columns, trusses, girders, beams, machine bases, anchor bolts, under the baseplates, etc. Grouting with "Shrinkcomp grout" of grade 40, the PVC pressure release pipes left in the raft (This item will be operative only if it is not covered under the scope of the waterproofing agency.) SUB-TOTAL

1.1

Litres

1.2

Litres

K.

COATINGS AND PAINTS OVER STRUCTURAL MEMBERS Providing and applying anti-corrosive epoxy based paint over exposed structural steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and application.

1.1

Sq.m

Section S.No.

ITEM DESCRIPTION Providing and applying intumiscent fire retarding paints of thickness not exceeding 1 mm for fire rating of one hour to exposed steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and Providing and applying low density single pack factory blended & controlled proven premix aggregate fireproof coating comprising of exfoliated vermiculite cement with fire protective additives and fillers as bonding and reinforcing agents designed to adhe SUB-TOTAL BRICKWORK AND RUBBLE STRUCTURAL PURPOSES WORK FOR

UNIT

QUANTITY

UNIT RATE

AMOUNT

1.2

Sq.m

1.3

Sq.m

L.

1.1

Material and labour, tools & plants for Randum rubble masonry in foundation and plinth etc. using cement mortar 1:4, including providing Header stones/Bond stones for every 0.50 Sq.m. of masonry surface, Corner stones/Quoin stones at corners not less than Rubble soling 230 mm thk using 230 mm thick down graded rubble (Basalt or Trap) and chips and cavities filled with smaller chips and stone dust, watering, compacted properly by mechanical means SUB-TOTAL SLEEVES Providing and placing during concreting within the formwork with appropriate G.I. hold fasts, G.I.('C' Class) Sleeves of various diameters and up to 500 mm length without flanges. Cost of providing reinforcement around the sleeves shall be paid under the up to 50 mm dia larger than 50 mm up to 100 mm dia larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia Providing and placing G.I.Sleeves of various diameters and up to 500 mm length, during concreting, projecting/protruding outside the formwork with appropriate G.I.hold fasts, flanges of appropriate standards and as per details shown on relevant services larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia SUB-TOTAL PRE-STRESSING TO CONCRETE Providing, placing / installing in position Prestressing steel in the specified form such as plain round wire, indented wire, grooved wire, two / three ply strand, seven/nineteen wire strands etc., standard anchors, dead end anchors, anchorage couplings,

Cu.m

1.2

Cu.m

200

M.

1.1 1.2 1.3 1.4 1.5 1.6 1.7

No. No. No. No. No. No. No.

2.1 2.2 2.3 2.4 2.5

No. No. No. No. No.

N.

Sq.m

34,165

Section S.No.

ITEM DESCRIPTION This item covers only pre-stressing materials and corresponding activities. Concrete, formwork and reinforcement shall be paid separately under respective items. The design of the post-tensioned slabs, beams or any other structural members is in the scope SUB-TOTAL GRAND TOTAL

UNIT

QUANTITY

UNIT RATE

AMOUNT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G07

SUMMARY OF BILL OF QUANTITIES FOR STRUCTURAL WORKS E BLOCK

NO.

DESCRIPTION

A B C D E F G H I J K

EXCAVATION BACKFILLING PLUM CONCRETE PLAIN CEMENT CONCRETE REINFORCED CEMENT CONCRETE SHUTTERING, FORMWORK & STAGING REINFORCEMENT STRUCTURAL STEEL EXPANSION JOINT GROUTING COATINGS AND PAINTS OVER STRUCTURAL MEMBERS BRICKWORK AND RUBBLE WORK FOR STRUCTURAL PURPOSES SLEEVES PRE-STRESSING TO CONCRETE GRAND TOTAL (A to N)

L M N

( Rupees

Only )

TENDERER

SUMMARY - Page 14 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

WORKS

AMOUNT
(In rupees)

Only )

TENDERER

SUMMARY - Page 15 of 106

CLIENT

HLL CAMPUS AT ANDHERI - BOQ FOR STRUCTURAL ITEMS


Section S.No. A 1 ITEM DESCRIPTION EXCAVATION AND EARTH WORK Excavation ( By mechanical & manual means ) :- All excavation Carrying out excavation in the specified type of soil, inclusive of de-watering to keep the area clear from water ponding at all times, to the required depth and profile as shown on drawings. The final layer of 300mm thickness shall be manually excavated. The unsuitable excavated earth, as directed by Project Manager, shall be carted away from the site and disposed in the approved dump yard of the local authority, by the contractor.The rate of excavation includes cost of all necessary licences and permis Contractor shall take all necessry steps to ensure that the temporary soil retention system (touching piles, diaphragm wall or any other shoring system) is not damaged or disturbed during the excavation activity. In case any damages occurred, the Contract The final approved founding strata shall be left absolutely clean by removing loose, slushy soil, murrum and weathered rocks with necessary tools & tackles, cleaning the surface by wire brush and carting away the debris, dewatering to keep site dry at all Mode of measurement for excavation carried out by Mechanical Appliances using various attachments such as bucket or rock breaker or chiesel shall be measured and paid as per IS 1200 Part -27. In case of excavation carried out by manual means the measureme Carrying out excavation in the specified type of soil, up to any lead and level, inclusive of dewatering to keep the area clear from water ponding till the time shoring, protecting the slopes/sides etc. is complete. The excavated earth (excluding a certain quantity of boulders and hard rock of size 600 mm and above, which is to be stacked properly within the site at the specified location) shall be carted away by the contractor. Contractor shall hand over the site as a whole or in phases as directed by the Engineer in Charge after removing soft soil, slush, mud, loose material, stone chips, from rock surface or any other founding strata, which is approved as the final block excav Excavation in all type soil for foundations,plinth beams,swimming pool,water tank,STP,compound wall foundation,trenches,etc. Trimming the vertical / inclined / horizontal soil of any type / weathered rock surfaces of already excavated pits of any size, for accommodating the required sizes and shapes of RCC members and other civil work items as shown in the drawings and describ SUB-TOTAL UNIT BLOCK E UNIT RATE AMOUNT

II

III

IV

VI

VII

VIII

1.4

Cu.m

1982

1.5

Cu.m

Section S.No. 2 2.1 2.2

ITEM DESCRIPTION BACKFILLING Backfilling with earth available at site Backfilling with earth brought from outside. The earth brought from outside shall be good quality murrum approved by Engineer in Charge. Filling with dry sand above raft as counterweight, for attaining the required levels in the lift pits and other pits as mentioned on drawings Filling in plinth or above RCC slab to make up the required level with good quality murrum SUB-TOTAL PLUM CONCRETE Providing and laying plum concrete course in plain cement concrete M:15 and evenly distributed plums of basalt or trap of size 160 mm and above up to any reasonable size to a maximum limit of 30% by volume of concrete including mechanically vibrating, co Filling in pits, excavated pits, in pockets of strata after removal of soft soil / weathered rock at founding level to level the surface before carrying out levelling PCC As counterweight over basement raft, using shuttering and formwork wherever necessary to create sumps, drains, slopes etc. In mass concreting for filling in lift pits, sumps, creating ramps etc. On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s SUB-TOTAL PLAIN CEMENT CONCRETE Providing and laying plain cement concrete M:15 including centering, vibrating, shuttering, compacting, curing, de-watering etc. complete. Below waterproofing layer, raft, foundations and plinth beams as levelling course In flooring above compacted dry sand filling / plum concrete filling/ rubble soling or compacted plinth filling, to a thickness of 150 mm to 300 mm after laying reinforcement if specified, the reinforcement work being paid for separately under the reinfor In mass concrete with or without formwork exceeding dimensions 1.0 m in at least one direction On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s

UNIT

BLOCK E

UNIT RATE

AMOUNT

Cu.m Cu.m

1298.89 324.72

2.3

Cu.m.

2.4

Cu.m

B.

1.1

Cu.m.

25

1.2 1.3

Cu.m. Cu.m.

25 25

1.4

Cu.m.

C.

1 1.1

Cu.m.

65.20

1.2

Cu.m.

192

1.3

Cu.m.

20

1.4

Cu.m.

Section S.No. SUB-TOTAL D.

ITEM DESCRIPTION

UNIT

BLOCK E

UNIT RATE

AMOUNT

REINFORCED CEMENT CONCRETE


Providing and laying premixed and transported to site, pumped / lifted at the location of pour with the contractors own arrangement , controlled reinforced cement concrete conforming to grade M: 40 (IS 4562000) with minimum cement content 360 kg/cum as The rate shall include for providing recesses to slabs, walls and columns and placing and securing properly within the form-work sleeves and/or openings in slabs, embodiments such as bolts, insert plates, corner protection angles, plates, anchors etc. (em The rates shall also account for any admixtures (approved by the consultants) the contractor may use in order to enhance the workability, to achieve accelerated strength, etc. The rate shall include use of plasticizers and retarders to limit the water/cem

Cu.m.

1804

II

SUB-TOTAL
2 Shuttering , Formwork and Staging Formwork/Shuttering- designing,obtaining approval of design for structural stability and method statement from Project Manager and Structural Consultant prior to commencement of the specific item well in advance, providing, erecting, fabricating, tying, f The rate shall include for providing recesses, cornices and ledges to slabs, beams, columns, walls, providing openings in slabs, walls, beams, making provisions for fixing inserts, sleeves etc. in concrete, making holes in form-work for taking out dowels The rate shall be separately quoted for the following :

0.1

Basement raft, Bottom raft of water tanks, Reinforced floor laid over subgrade/PCC levelling course/Plinth filling/Plum Concrete or Waterproofing layer, to be laid in panels of predetermined dimensions having approved construction joints. Isolated, combined or strip foundations or pilecaps for columns, shear walls and lift walls (projections above raft in case of footings or pilecaps monolithic with the raft, and full volume of the footings or pilecaps in case of isolated or combined footi Machine foundations and mass concreting

Sqm

0.2

Sqm

423

0.3

Sqm

50

Section S.No. 2

ITEM DESCRIPTION Walls and Retaining Walls Parallel faced or tapered retaining walls for basement, swimming pool, underground and above-ground tanks, trenches, gutters, drains etc. Shear walls and lift walls of any thickness and any shape in plan with straight faces. Retaining wall below compound wall to achieve level difference between adjoining plots/areas. Columns Columns may be free standing or integrated with shear / lift walls, they may be floating on or hanging from beams. Rectangular, T shaped, L shaped or square columns, pedestals and stub columns, buttresses for retaining walls. Circular or oval columns, pedestals and stub columns. Columns, pedestals and stub columns of any other shapes with straight faces Columns inclined in elevation

UNIT

BLOCK E

UNIT RATE

AMOUNT

2.1

Sqm

2.2 2.3 3

Sqm Sqm

764 25

3.1

Sqm

1667

3.2

Sqm

15

3.3 3.4

Sqm Sqm

5 5

Beams Beams include simply supported, continuous, cantilevers and may be spaced at any distance, may or may not be integrated with RCC/Steel beams. Beams straight in plan & elevation, including ribs of ribbed floor Beams curved in plan Brackets and ledges from columns, walls, beams etc Lintels precast or cast in situ (rate to include erection of precast lintels) RCC transfer girders carrying flooting columns,more than 400 mm in width and 2000 mm in depth.

4.1 4.2 4.3

Sqm Sqm Sqm

725 1000 5

4.4

Sqm

50

4.5

Sqm

1200

Slabs Horizontal slabs integrated with concrete beams, ribs, structural steel beams or truss / girder members, or flat slabs with or without drop panels, (drop panel being measured as slab with its own thickness). 100 mm thick 125 mm thick 150 mm thick 175 mm thick Sqm Sqm Sqm Sqm 5 5 3646 1917

5.1

a. b. c. d.

Section S.No. e. f. g. h. i. j. 200 mm thick 225 mm thick 250 mm thick 275 mm thick 300 mm thick

ITEM DESCRIPTION

UNIT Sqm Sqm Sqm Sqm Sqm Sqm

BLOCK E 1088 5 5 5 -

UNIT RATE

AMOUNT

Above 300 upto 400 mm thickness Extra over 5.1 for any thickness for providing slope up to 1 in 10 to slab to its bottom and/or to its top Extra over 5.1 for any thickness for providing slope between 1 in 5 and 1 in 10" to slab to its bottom and/or to its top Chajjas, ledges of thickness 75 mm to 150 mm, horizontal or sloping, upto 900 mm cantilever projection Chajjas, ledges of thickness more than 150 and upto 175 mm, horizontal or sloping upto 900 mm cantilever projection
Chajjas, ledges of thickness more than 175 and upto 250 mm, horizontal or sloping upto 2000 mm cantilever projection .

5.2

Sqm

5.3

Sqm

5.4

Sqm

5.5

Sqm

5.6

Sq.m

Staircases Staircase including waist slab and steps. Midlanding slab will be measured in this item. Pardis will be measulred under item 7 below. Pardis, drop pardis and parapets Vertical, sloping and upstand pardis, drop pardis, parapets of thickness up to 200 mm. Vertical, sloping pardis and drop pardis above 200 mm thickness Parapets in concrete block above 200 mm thickness Coping over parapets Precast Reinforced Concrete Members Extra over D.4 to D.7 including sub-items described therein, for pre-casting the RCC members using specified class of surface finish in respective items, with necessary anchorage projections or recesses as per drawings and details, lifting, placing and gr Making Pre-cast curb blocks, parapets, dividers, fencing posts, paving slabs, sump and manhole covers etc., lifting, transporting to any lead, and placing them at any height in position, grouting complete. Maximum weight of such pre-cast member shall be 2 Closing the openings Sqm -

6.1

Sqm

349

7 7.1

7.2

Sqm

7.3 7.4 8

Sqm Sqm

8.1

Sqm

8.2

Sqm

Section S.No.

ITEM DESCRIPTION Concreting slabs in the openings and holes after installation of services, taking due care not to damage or disturb the installations, by providing shuttering and staging around the existing pipes, ducts etc. This item is valid for openings shown on the c

UNIT

BLOCK E

UNIT RATE

AMOUNT

9.1

Sq.m

E.

DEVIATION IN CONCRETE GRADE, MIX AND RENDERING 1 1.1 1.2 2 2.1 2.2 2.3 2.4 Extra over item D for providing in place of M:40 mix M:50 mix with approved design M:60 mix with approved design Reduction in rate of item D for providing in place of M:40 mix M:35 mix with approved design M:30 mix with approved design M:25 mix with approved design M:20 mix with approved design

Cu.m Cu.m

Quote Quote

Cu.m Cu.m Cu.m Cu.m

Quote Quote Quote Quote

F.

SPECIAL STAGING, FORMWORK & PROPPING Extra over item no. D.1 to D.8 including their sub items and deviation in rates for suspended floor slabs, roof slabs, balcony slabs using preengineered shuttering supported on structural steel beams, trussed beams and/or plate girders without taking any Extra over item no. D.1 to D.8 including their sub items and deviation in rates for supporting slabs and beams requiring staging heights more than 4.5 m from floor to floor for every 1.0 m increase as described below. The rate is for the concrete volume s This item is not valid for the staging to be erected at the lower basement level for supporting the shuttering of the upper basement (B1 level) slab. It may be noted that if plum concrete filling is carried out immediately after casting B2 level raft, the More than 4.5 m upto 5.5 m More than 5.5 m upto 6.5 m More than 6.5 m upto 7.5 m More than 7.5 m upto 8.5 m More than 8.5 m upto 9.5 m SUB-TOTAL REINFORCEMENT Providing and fixing steel reinforcement for RCC including material, fabricating as per IS 2502, transporting, storing, de-coiling, straightening, cutting, bending, spirally hooping and placing in position at all levels, including all labour, equipments, The quoted rate will include welding of reinforcement with low hydrogen low heat welding electrodes for the welding length mentioned in the drawings in place of conventional laps, wherever consultants recommend, for which no extra shall be claimed. Replac

II

III

1.1 1.2 1.3 1.4 1.5

Cu.m Cu.m Cu.m Cu.m Cu.m

Quote Quote Quote Quote Quote

G.

II

Section S.No.

ITEM DESCRIPTION

UNIT

BLOCK E

UNIT RATE

AMOUNT

III

1 2

The rate also includes protecting the reinforcing bars in their virgin form or in the fabricated form, or when placed and tied up in position or as dowels left for future continuation of work or at construction joint against corrosion due to exposure High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 500 N/sq.mm High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 415 N/sq.mm

Quote 208

Providing, fixing, aligning threaded tapered couplers for reinforcement wherever specified in the drawings for continuation / splicing of bars as recommended by the manufacturers. The item includes machining the reinforcing bars to match the threads of th 16 mm dia or reduction coupler 16/12mm 20 mm dia or reduction coupler 20/16mm 25 mm dia or reduction coupler 25/20mm 32 mm dia or reduction coupler 32/25mm 36 mm dia or reduction coupler 36/32mm 40 mm dia or reduction coupler 40/36mm SUB-TOTAL STRUCTURAL ERECTION STEEL FABRICATION AND Nos. Nos. Nos. Nos. Nos. Nos. Quote Quote Quote Quote Quote Quote

2.1 2.2 2.3 2.4 2.5 2.6

Fabrication from local structural steel plates and sections Preparing shop drawings, obtaining Structural consultants approval, supplying, fabricating in accordance with IS:800, delivering at site, hoisting M.Tons and fixing in position, including all temporary staging and supporting work and making all structural steel

Fabricating columns, beams, joists, struts, built up ties and bracings, staircases, tressles, platforms, lofts, catwalks, walkways, bridges, ladders, brackets, suspended canopy etc.and other steel members and items out of the following readily available s a b c d e f I and H sections of any size Channels of any size Angles of any size Hollow rectangular or square sections Hollow circular tubes Plates

Supplying, fabricating and installing inserts in concrete in the form of mild steel angles, flats, plates, holding down bolts, angle frames, etc. with M.Tons anchors in the form of rods or flats including welding anchors, lifting hooks, rungs, templates etc., al Supplying and fixing expandable anchor bolts in concrete or masonry including drilling, cleaning the holes, ramming the bolts in the holes in accordance with manufacturers procedures, recommendations and specifications for fixing plates or other steel me

Section S.No. 4.1 4.2 4.3 4.4 4.5

ITEM DESCRIPTION 10 mm core diameter 12 mm core diameter 16 mm core diameter 20 mm core diameter 25 mm core diameter Supplying, cutting to shape, securing to the supporting members with bolts or welding as shown on drawings, M.S.Chequered plate. The rate shall be for the actually placed plate and not for the procured quantity. 6 mm thick 8 mm thick SUB-TOTAL EXPANSION JOINTS Providing expansion joint between structural members by fixing 50 mm thick asphalt impregnated soft board on one surface to serve as shuttering and finishing the expansion joint neatly as per detailed drawing. Sealing the expansion joint with 50 mm x 32 mm approved quality polymer based silicone sealant from external as well as internal side as per manufacturers requirement . Providing and laying aluminium flashing 0.5 mm thk bent to shape over expansion joint, fixed to the concrete surface on one side of the expansion joint as shown in the structural drawings. SUB-TOTAL

UNIT Nos. Nos. Nos. Nos. Nos.

BLOCK E Quote Quote Quote Quote Quote

UNIT RATE

AMOUNT

5.1 5.1

Sq.m Sq.m

Quote Quote

I.

Sq.m

Quote

R.M.

Quote

R.M.

Quote

J.

GROUTING Providing and grouting with polymer mixed cementatious low viscous grout of minimum strength of 40 N/sq.mm (that of the parent reinforced concrete member) as per manufacturers recommendations of approved quality and brand Under the bases and in the pockets left for the foundation bolts of structural steel columns, trusses, girders, beams, machine bases, anchor bolts, under the baseplates, etc. Grouting with "Shrinkcomp grout" of grade 40, the PVC pressure release pipes left in the raft (This item will be operative only if it is not covered under the scope of the waterproofing agency.) SUB-TOTAL

1.1

Litres

1.2

Litres

K.

COATINGS AND PAINTS OVER STRUCTURAL MEMBERS Providing and applying anti-corrosive epoxy based paint over exposed structural steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and application.

1.1

Sq.m

Quote

Section S.No.

ITEM DESCRIPTION Providing and applying intumiscent fire retarding paints of thickness not exceeding 1 mm for fire rating of one hour to exposed steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and Providing and applying low density single pack factory blended & controlled proven premix aggregate fireproof coating comprising of exfoliated vermiculite cement with fire protective additives and fillers as bonding and reinforcing agents designed to adhe SUB-TOTAL BRICKWORK AND RUBBLE STRUCTURAL PURPOSES WORK FOR

UNIT

BLOCK E

UNIT RATE

AMOUNT

1.2

Sq.m

Quote

1.3

Sq.m

Quote

L.

1.1

Material and labour, tools & plants for Randum rubble masonry in foundation and plinth etc. using cement mortar 1:4, including providing Header stones/Bond stones for every 0.50 Sq.m. of masonry surface, Corner stones/Quoin stones at corners not less than Rubble soling 230 mm thk using 230 mm thick down graded rubble (Basalt or Trap) and chips and cavities filled with smaller chips and stone dust, watering, compacted properly by mechanical means SUB-TOTAL SLEEVES Providing and placing during concreting within the formwork with appropriate G.I. hold fasts, G.I.('C' Class) Sleeves of various diameters and up to 500 mm length without flanges. Cost of providing reinforcement around the sleeves shall be paid under the up to 50 mm dia larger than 50 mm up to 100 mm dia larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia Providing and placing G.I.Sleeves of various diameters and up to 500 mm length, during concreting, projecting/protruding outside the formwork with appropriate G.I.hold fasts, flanges of appropriate standards and as per details shown on relevant services larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia SUB-TOTAL PRE-STRESSING TO CONCRETE Providing, placing / installing in position Prestressing steel in the specified form such as plain round wire, indented wire, grooved wire, two / three ply strand, seven/nineteen wire strands etc., standard anchors, dead end anchors, anchorage couplings,

Cu.m

Quote

1.2

Cu.m

310

M.

1.1 1.2 1.3 1.4 1.5 1.6 1.7

No. No. No. No. No. No. No.

Quote Quote Quote Quote Quote Quote Quote

2.1 2.2 2.3 2.4 2.5

No. No. No. No. No.

Quote Quote Quote Quote Quote

N.

Sq.m

Section S.No.

ITEM DESCRIPTION This item covers only pre-stressing materials and corresponding activities. Concrete, formwork and reinforcement shall be paid separately under respective items. The design of the post-tensioned slabs, beams or any other structural members is in the scope SUB-TOTAL GRAND TOTAL

UNIT

BLOCK E

UNIT RATE

AMOUNT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G07

SUMMARY OF BILL OF QUANTITIES FOR STRUCTURAL WORKS F BLOCK

NO.

DESCRIPTION

A B C D E F G H I J K

EXCAVATION BACKFILLING PLUM CONCRETE PLAIN CEMENT CONCRETE REINFORCED CEMENT CONCRETE SHUTTERING, FORMWORK & STAGING REINFORCEMENT STRUCTURAL STEEL EXPANSION JOINT GROUTING COATINGS AND PAINTS OVER STRUCTURAL MEMBERS BRICKWORK AND RUBBLE WORK FOR STRUCTURAL PURPOSES SLEEVES PRE-STRESSING TO CONCRETE GRAND TOTAL (A to N)

L M N

( Rupees

Only )

TENDERER

SUMMARY - Page 26 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

WORKS

(In rupees)

Only )

TENDERER

SUMMARY - Page 27 of 106

CLIENT

HLL CAMPUS AT ANDHERI - BOQ FOR STRUCTURAL ITEMS


Section S.No. A 1 ITEM DESCRIPTION EXCAVATION AND EARTH WORK Excavation ( By mechanical & manual means ) :- All excavation Carrying out excavation in the specified type of soil, inclusive of de-watering to keep the area clear from water ponding at all times, to the required depth and profile as shown on drawings. The final layer of 300mm thickness shall be manually excavated. The unsuitable excavated earth, as directed by Project Manager, shall be carted away from the site and disposed in the approved dump yard of the local authority, by the contractor.The rate of excavation includes cost of all necessary licences and permis Contractor shall take all necessry steps to ensure that the temporary soil retention system (touching piles, diaphragm wall or any other shoring system) is not damaged or disturbed during the excavation activity. In case any damages occurred, the Contract The final approved founding strata shall be left absolutely clean by removing loose, slushy soil, murrum and weathered rocks with necessary tools & tackles, cleaning the surface by wire brush and carting away the debris, dewatering to keep site dry at all Mode of measurement for excavation carried out by Mechanical Appliances using various attachments such as bucket or rock breaker or chiesel shall be measured and paid as per IS 1200 Part -27. In case of excavation carried out by manual means the measureme Carrying out excavation in the specified type of soil, up to any lead and level, inclusive of dewatering to keep the area clear from water ponding till the time shoring, protecting the slopes/sides etc. is complete. The excavated earth (excluding a certain quantity of boulders and hard rock of size 600 mm and above, which is to be stacked properly within the site at the specified location) shall be carted away by the contractor. Contractor shall hand over the site as a whole or in phases as directed by the Engineer in Charge after removing soft soil, slush, mud, loose material, stone chips, from rock surface or any other founding strata, which is approved as the final block excav Excavation in all type soil for foundations,plinth beams,swimming pool,water tank,STP,compound wall foundation,trenches,etc. Trimming the vertical / inclined / horizontal soil of any type / weathered rock surfaces of already excavated pits of any size, for accommodating the required sizes and shapes of RCC members and other civil work items as shown in the drawings and describ SUB-TOTAL UNIT BLOCK F UNIT RATE AMOUNT

II

III

IV

VI

VII

VIII

1.4

Cu.m

3951

1.5

Cu.m

Section S.No. 2 2.1 2.2

ITEM DESCRIPTION BACKFILLING Backfilling with earth available at site Backfilling with earth brought from outside. The earth brought from outside shall be good quality murrum approved by Engineer in Charge. Filling with dry sand above raft as counterweight, for attaining the required levels in the lift pits and other pits as mentioned on drawings Filling in plinth or above RCC slab to make up the required level with good quality murrum SUB-TOTAL PLUM CONCRETE Providing and laying plum concrete course in plain cement concrete M:15 and evenly distributed plums of basalt or trap of size 160 mm and above up to any reasonable size to a maximum limit of 30% by volume of concrete including mechanically vibrating, co Filling in pits, excavated pits, in pockets of strata after removal of soft soil / weathered rock at founding level to level the surface before carrying out levelling PCC As counterweight over basement raft, using shuttering and formwork wherever necessary to create sumps, drains, slopes etc. In mass concreting for filling in lift pits, sumps, creating ramps etc. On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s SUB-TOTAL PLAIN CEMENT CONCRETE Providing and laying plain cement concrete M:15 including centering, vibrating, shuttering, compacting, curing, de-watering etc. complete. Below waterproofing layer, raft, foundations and plinth beams as levelling course In flooring above compacted dry sand filling / plum concrete filling/ rubble soling or compacted plinth filling, to a thickness of 150 mm to 300 mm after laying reinforcement if specified, the reinforcement work being paid for separately under the reinfor In mass concrete with or without formwork exceeding dimensions 1.0 m in at least one direction On vertical surfaces between the soil retention system and the permanent retaining wall to act as formwork to the external face of the permanent retaining wall and/or to receive waterproofing layer before casting the permanent retaining wall against the s

UNIT

BLOCK F

UNIT RATE

AMOUNT

Cu.m Cu.m

2519.61 629.90

2.3

Cu.m.

2.4

Cu.m

B.

1.1

Cu.m.

25

1.2 1.3

Cu.m. Cu.m.

25 25

1.4

Cu.m.

C.

1 1.1

Cu.m.

131.70

1.2

Cu.m.

244

1.3

Cu.m.

20

1.4

Cu.m.

Section S.No. SUB-TOTAL D.

ITEM DESCRIPTION

UNIT

BLOCK F

UNIT RATE

AMOUNT

REINFORCED CEMENT CONCRETE


Providing and laying premixed and transported to site, pumped / lifted at the location of pour with the contractors own arrangement , controlled reinforced cement concrete conforming to grade M: 40 (IS 4562000) with minimum cement content 360 kg/cum as The rate shall include for providing recesses to slabs, walls and columns and placing and securing properly within the form-work sleeves and/or openings in slabs, embodiments such as bolts, insert plates, corner protection angles, plates, anchors etc. (em The rates shall also account for any admixtures (approved by the consultants) the contractor may use in order to enhance the workability, to achieve accelerated strength, etc. The rate shall include use of plasticizers and retarders to limit the water/cem

Cu.m.

4921

II

SUB-TOTAL
2 Shuttering , Formwork and Staging Formwork/Shuttering- designing,obtaining approval of design for structural stability and method statement from Project Manager and Structural Consultant prior to commencement of the specific item well in advance, providing, erecting, fabricating, tying, f The rate shall include for providing recesses, cornices and ledges to slabs, beams, columns, walls, providing openings in slabs, walls, beams, making provisions for fixing inserts, sleeves etc. in concrete, making holes in form-work for taking out dowels The rate shall be separately quoted for the following :

0.1

Basement raft, Bottom raft of water tanks, Reinforced floor laid over subgrade/PCC levelling course/Plinth filling/Plum Concrete or Waterproofing layer, to be laid in panels of predetermined dimensions having approved construction joints. Isolated, combined or strip foundations or pilecaps for columns, shear walls and lift walls (projections above raft in case of footings or pilecaps monolithic with the raft, and full volume of the footings or pilecaps in case of isolated or combined footi Machine foundations and mass concreting

Sqm

0.2

Sqm

1057

0.3

Sqm

50

Section S.No. 2

ITEM DESCRIPTION Walls and Retaining Walls Parallel faced or tapered retaining walls for basement, swimming pool, underground and above-ground tanks, trenches, gutters, drains etc. Shear walls and lift walls of any thickness and any shape in plan with straight faces. Retaining wall below compound wall to achieve level difference between adjoining plots/areas. Columns Columns may be free standing or integrated with shear / lift walls, they may be floating on or hanging from beams. Rectangular, T shaped, L shaped or square columns, pedestals and stub columns, buttresses for retaining walls. Circular or oval columns, pedestals and stub columns. Columns, pedestals and stub columns of any other shapes with straight faces Columns inclined in elevation

UNIT

BLOCK F

UNIT RATE

AMOUNT

2.1

Sqm

2.2 2.3 3

Sqm Sqm

1225 50

3.1

Sqm

6404

3.2

Sqm

15

3.3 3.4

Sqm Sqm

5 5

Beams Beams include simply supported, continuous, cantilevers and may be spaced at any distance, may or may not be integrated with RCC/Steel beams. Beams straight in plan & elevation, including ribs of ribbed floor Beams curved in plan Brackets and ledges from columns, walls, beams etc Lintels precast or cast in situ (rate to include erection of precast lintels) RCC transfer girders carrying flooting columns,more than 400 mm in width and 2000 mm in depth.

4.1 4.2 4.3

Sqm Sqm Sqm

8119 1800 5

4.4

Sqm

50

4.5

Sqm

4000

Slabs Horizontal slabs integrated with concrete beams, ribs, structural steel beams or truss / girder members, or flat slabs with or without drop panels, (drop panel being measured as slab with its own thickness). 100 mm thick 125 mm thick 150 mm thick 175 mm thick Sqm Sqm Sqm Sqm 5 5 3921 5

5.1

a. b. c. d.

Section S.No. e. f. g. h. i. j. 200 mm thick 225 mm thick 250 mm thick 275 mm thick 300 mm thick

ITEM DESCRIPTION

UNIT Sqm Sqm Sqm Sqm Sqm Sqm

BLOCK F 2753 5 5 5 -

UNIT RATE

AMOUNT

Above 300 upto 400 mm thickness Extra over 5.1 for any thickness for providing slope up to 1 in 10 to slab to its bottom and/or to its top Extra over 5.1 for any thickness for providing slope between 1 in 5 and 1 in 10" to slab to its bottom and/or to its top Chajjas, ledges of thickness 75 mm to 150 mm, horizontal or sloping, upto 900 mm cantilever projection Chajjas, ledges of thickness more than 150 and upto 175 mm, horizontal or sloping upto 900 mm cantilever projection
Chajjas, ledges of thickness more than 175 and upto 250 mm, horizontal or sloping upto 2000 mm cantilever projection .

5.2

Sqm

5.3

Sqm

5.4

Sqm

5.5

Sqm

5.6

Sq.m

Staircases Staircase including waist slab and steps. Midlanding slab will be measured in this item. Pardis will be measulred under item 7 below. Pardis, drop pardis and parapets Vertical, sloping and upstand pardis, drop pardis, parapets of thickness up to 200 mm. Vertical, sloping pardis and drop pardis above 200 mm thickness Parapets in concrete block above 200 mm thickness Coping over parapets Precast Reinforced Concrete Members Extra over D.4 to D.7 including sub-items described therein, for pre-casting the RCC members using specified class of surface finish in respective items, with necessary anchorage projections or recesses as per drawings and details, lifting, placing and gr Making Pre-cast curb blocks, parapets, dividers, fencing posts, paving slabs, sump and manhole covers etc., lifting, transporting to any lead, and placing them at any height in position, grouting complete. Maximum weight of such pre-cast member shall be 2 Closing the openings Sqm -

6.1

Sqm

824

7 7.1

7.2

Sqm

7.3 7.4 8

Sqm Sqm

8.1

Sqm

8.2

Sqm

Section S.No.

ITEM DESCRIPTION Concreting slabs in the openings and holes after installation of services, taking due care not to damage or disturb the installations, by providing shuttering and staging around the existing pipes, ducts etc. This item is valid for openings shown on the c

UNIT

BLOCK F

UNIT RATE

AMOUNT

9.1

Sq.m

E.

DEVIATION IN CONCRETE GRADE, MIX AND RENDERING 1 1.1 1.2 2 2.1 2.2 2.3 2.4 Extra over item D for providing in place of M:40 mix M:50 mix with approved design M:60 mix with approved design Reduction in rate of item D for providing in place of M:40 mix M:35 mix with approved design M:30 mix with approved design M:25 mix with approved design M:20 mix with approved design

Cu.m Cu.m

Quote Quote

Cu.m Cu.m Cu.m Cu.m

Quote Quote Quote Quote

F.

SPECIAL STAGING, FORMWORK & PROPPING Extra over item no. D.1 to D.8 including their sub items and deviation in rates for suspended floor slabs, roof slabs, balcony slabs using preengineered shuttering supported on structural steel beams, trussed beams and/or plate girders without taking any Extra over item no. D.1 to D.8 including their sub items and deviation in rates for supporting slabs and beams requiring staging heights more than 4.5 m from floor to floor for every 1.0 m increase as described below. The rate is for the concrete volume s This item is not valid for the staging to be erected at the lower basement level for supporting the shuttering of the upper basement (B1 level) slab. It may be noted that if plum concrete filling is carried out immediately after casting B2 level raft, the More than 4.5 m upto 5.5 m More than 5.5 m upto 6.5 m More than 6.5 m upto 7.5 m More than 7.5 m upto 8.5 m More than 8.5 m upto 9.5 m SUB-TOTAL REINFORCEMENT Providing and fixing steel reinforcement for RCC including material, fabricating as per IS 2502, transporting, storing, de-coiling, straightening, cutting, bending, spirally hooping and placing in position at all levels, including all labour, equipments, The quoted rate will include welding of reinforcement with low hydrogen low heat welding electrodes for the welding length mentioned in the drawings in place of conventional laps, wherever consultants recommend, for which no extra shall be claimed. Replac

II

III

1.1 1.2 1.3 1.4 1.5

Cu.m Cu.m Cu.m Cu.m Cu.m

Quote Quote Quote Quote Quote

G.

II

Section S.No.

ITEM DESCRIPTION

UNIT

BLOCK F

UNIT RATE

AMOUNT

III

1 2

The rate also includes protecting the reinforcing bars in their virgin form or in the fabricated form, or when placed and tied up in position or as dowels left for future continuation of work or at construction joint against corrosion due to exposure High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 500 N/sq.mm High yield strength deformed bars conforming to M.Tons IS:1786 with Fy = 415 N/sq.mm

Quote 616

Providing, fixing, aligning threaded tapered couplers for reinforcement wherever specified in the drawings for continuation / splicing of bars as recommended by the manufacturers. The item includes machining the reinforcing bars to match the threads of th 16 mm dia or reduction coupler 16/12mm 20 mm dia or reduction coupler 20/16mm 25 mm dia or reduction coupler 25/20mm 32 mm dia or reduction coupler 32/25mm 36 mm dia or reduction coupler 36/32mm 40 mm dia or reduction coupler 40/36mm SUB-TOTAL STRUCTURAL ERECTION STEEL FABRICATION AND Nos. Nos. Nos. Nos. Nos. Nos. Quote Quote Quote Quote Quote Quote

2.1 2.2 2.3 2.4 2.5 2.6

Fabrication from local structural steel plates and sections Preparing shop drawings, obtaining Structural consultants approval, supplying, fabricating in accordance with IS:800, delivering at site, hoisting M.Tons and fixing in position, including all temporary staging and supporting work and making all structural steel

Fabricating columns, beams, joists, struts, built up ties and bracings, staircases, tressles, platforms, lofts, catwalks, walkways, bridges, ladders, brackets, suspended canopy etc.and other steel members and items out of the following readily available s a b c d e f I and H sections of any size Channels of any size Angles of any size Hollow rectangular or square sections Hollow circular tubes Plates

Supplying, fabricating and installing inserts in concrete in the form of mild steel angles, flats, plates, holding down bolts, angle frames, etc. with M.Tons anchors in the form of rods or flats including welding anchors, lifting hooks, rungs, templates etc., al Supplying and fixing expandable anchor bolts in concrete or masonry including drilling, cleaning the holes, ramming the bolts in the holes in accordance with manufacturers procedures, recommendations and specifications for fixing plates or other steel me

Section S.No. 4.1 4.2 4.3 4.4 4.5

ITEM DESCRIPTION 10 mm core diameter 12 mm core diameter 16 mm core diameter 20 mm core diameter 25 mm core diameter Supplying, cutting to shape, securing to the supporting members with bolts or welding as shown on drawings, M.S.Chequered plate. The rate shall be for the actually placed plate and not for the procured quantity. 6 mm thick 8 mm thick SUB-TOTAL EXPANSION JOINTS Providing expansion joint between structural members by fixing 50 mm thick asphalt impregnated soft board on one surface to serve as shuttering and finishing the expansion joint neatly as per detailed drawing. Sealing the expansion joint with 50 mm x 32 mm approved quality polymer based silicone sealant from external as well as internal side as per manufacturers requirement . Providing and laying aluminium flashing 0.5 mm thk bent to shape over expansion joint, fixed to the concrete surface on one side of the expansion joint as shown in the structural drawings. SUB-TOTAL

UNIT Nos. Nos. Nos. Nos. Nos.

BLOCK F Quote Quote Quote Quote Quote

UNIT RATE

AMOUNT

5.1 5.1

Sq.m Sq.m

Quote Quote

I.

Sq.m

Quote

R.M.

Quote

R.M.

Quote

J.

GROUTING Providing and grouting with polymer mixed cementatious low viscous grout of minimum strength of 40 N/sq.mm (that of the parent reinforced concrete member) as per manufacturers recommendations of approved quality and brand Under the bases and in the pockets left for the foundation bolts of structural steel columns, trusses, girders, beams, machine bases, anchor bolts, under the baseplates, etc. Grouting with "Shrinkcomp grout" of grade 40, the PVC pressure release pipes left in the raft (This item will be operative only if it is not covered under the scope of the waterproofing agency.) SUB-TOTAL

1.1

Litres

1.2

Litres

K.

COATINGS AND PAINTS OVER STRUCTURAL MEMBERS Providing and applying anti-corrosive epoxy based paint over exposed structural steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and application.

1.1

Sq.m

Quote

Section S.No.

ITEM DESCRIPTION Providing and applying intumiscent fire retarding paints of thickness not exceeding 1 mm for fire rating of one hour to exposed steel work at any height in its finally erected position as per manufacturer's recommendations regarding surface treatment and Providing and applying low density single pack factory blended & controlled proven premix aggregate fireproof coating comprising of exfoliated vermiculite cement with fire protective additives and fillers as bonding and reinforcing agents designed to adhe SUB-TOTAL BRICKWORK AND RUBBLE STRUCTURAL PURPOSES WORK FOR

UNIT

BLOCK F

UNIT RATE

AMOUNT

1.2

Sq.m

Quote

1.3

Sq.m

Quote

L.

1.1

Material and labour, tools & plants for Randum rubble masonry in foundation and plinth etc. using cement mortar 1:4, including providing Header stones/Bond stones for every 0.50 Sq.m. of masonry surface, Corner stones/Quoin stones at corners not less than Rubble soling 230 mm thk using 230 mm thick down graded rubble (Basalt or Trap) and chips and cavities filled with smaller chips and stone dust, watering, compacted properly by mechanical means SUB-TOTAL SLEEVES Providing and placing during concreting within the formwork with appropriate G.I. hold fasts, G.I.('C' Class) Sleeves of various diameters and up to 500 mm length without flanges. Cost of providing reinforcement around the sleeves shall be paid under the up to 50 mm dia larger than 50 mm up to 100 mm dia larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia Providing and placing G.I.Sleeves of various diameters and up to 500 mm length, during concreting, projecting/protruding outside the formwork with appropriate G.I.hold fasts, flanges of appropriate standards and as per details shown on relevant services larger than 100 mm up to 150 mm dia larger than 150 mm up to 200 mm dia larger than 200 mm up to 250 mm dia larger than 250 mm up to 300 mm dia larger than 300 mm up to 400 mm dia SUB-TOTAL PRE-STRESSING TO CONCRETE Providing, placing / installing in position Prestressing steel in the specified form such as plain round wire, indented wire, grooved wire, two / three ply strand, seven/nineteen wire strands etc., standard anchors, dead end anchors, anchorage couplings,

Cu.m

Quote

1.2

Cu.m

400

M.

1.1 1.2 1.3 1.4 1.5 1.6 1.7

No. No. No. No. No. No. No.

Quote Quote Quote Quote Quote Quote Quote

2.1 2.2 2.3 2.4 2.5

No. No. No. No. No.

Quote Quote Quote Quote Quote

N.

Sq.m

Section S.No.

ITEM DESCRIPTION This item covers only pre-stressing materials and corresponding activities. Concrete, formwork and reinforcement shall be paid separately under respective items. The design of the post-tensioned slabs, beams or any other structural members is in the scope SUB-TOTAL GRAND TOTAL

UNIT

BLOCK F

UNIT RATE

AMOUNT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G07

JULY 23' 2007

SUMMARY OF BILL OF QUANTITIES FOR CIVIL WORKS FOR 'A', 'B' & 'D' BLOCKS,

NO.

DESCRIPTION

AMOUNT
(In rupees)

A B C D E F G H

MASONRY WORKS PLASTERING WORKS WATERPROOFING WORKS FLOORING WORKS PAINTING WORKS DOORS AND WINDOWS STEEL AND METAL WORKS GENERAL ITEMS GRAND TOTAL (A to E)

( Rupees

Only )

TENDERER

SUMMARY - Page 38 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G07

JULY 23' 2007

BILL OF QUANTITIES FOR CIVIL WORKS FOR 'A', 'B' & 'D' BLOCKS, AT HLL CAMPUS, ANDHERI,
SR NO SECTION-A MASONRY
Providing and constructing 200 mm thk SOLID CEMENT CONCRETE BLOCKS masonry in CM 1:5 ( 1 cement and 5 coarse A1 sand) including with good quality locally available or site manufactured solid concrete blocks, having minimum strength of 70 kg./ sq.cms and wa For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and constructing 150 mm thk SOLID CEMENT CONCRETE BLOCKS masory in CM 1:5 ( 1 cement and 5 coarse A2 sand) including with good quality locally available or site manufactured solid concrete blocks , having minimum strength of 70 kg./ sq.cms and For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 39 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and constructing 200 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , A3 having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and constructing 150 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , A4 having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and constructing 230 mm thk Burnt Brick masory in CM 1:6 ( 1 cement and 6 coarse sand) including with good quality locally A5 available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum .by weight. ,in specified For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO 970 1,835 476 1,038 1,038 476 475

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 40 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
sq.mt. QRO

RATE

AMOUNT

Providing and constructing 150 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally A6 available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 5,826 2,690 1,491 2,801 1,318 1,439 1,439 1,318 337

Providing and constructing 100 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally A7 available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and laying (second class burnt) brick masonry in 1:6 C.M , A8 above and below plinth and at all levels including for odd shaped walls , steps , brick fins , columns, etc. complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block cum cum cum cum cum cum cum cum cum QRO 431 49 QRO 186 155 155 186 58 sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO 765 1,678 2,026 QRO 550 550 QRO QRO

TENDERER

BOQ -Page 41 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and constructing 200mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints A9 and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and constructing 100mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints A10 and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing, laying and filling to required slope in toilet, W.C block with A11 siporex blocks in lime mortar, ramming compacting etc. complete as directed. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt.

QRO 24 42 122 QRO 49 49 QRO 7

Providing and constructing uncoursed random rubble masonry wall of local stones for foundations upto highest plinth level in CM 1:4, A12 ( 1 cement, 4 coarse sand) including curing, striking off joints on wall faces, scaffolding, providing weep For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. cu.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 42 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and fixing 150mm thick precast RCC Screen Element in 1:3:6 cement concrete with light mesh reinforcement with sharp A13 finished edges as per design and drawing including 21 days curing before transportation, hoisting and fixing at site etc comple For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Total of Section A SECTION-B PLASTER Providing and applying 20mm thk SAND FACE PLASTER in two coats at all heights in 15mm thk base coat of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions and finished with minimum 6mm B1 thicknes including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 1,000 1,838 1,411 2,408 1,533 2,353 2,353 1,533 768 sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

Providing and applying 12mm thk EXTERNAL SAND FACED PLASTER in SINGLE coat for ducts and shafts at all height of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions on all types of B2 concrete including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 1,167 590 555 1,802 418 559 559 418 336

TENDERER

BOQ -Page 43 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and Applying 12mm INTERNAL SINGLE COAT CEMENT PLASTER ( scratch coat plaster / trowel finish) in cement mortar 1:4 with waterproofing compound, as base coat for cladding work, to be of rough finish, to recieve Finishing, at all heights including including B3 providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'B2' Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 15,732 6,911 6,834 12,032 1,786 3,479 3,479 1,786 487

Providing & applying GYPSUM PLASTER as per manufactureres instruction / specs with minimum 12 mm thick on walls, beams,columns , ceiling etc including jambs, cill, in perfect line and level over newly concreted RCC surfaces , C.C block masonry , and B4 including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing Plaster of Paris finish to plastered surfaces in all positions including scaffolding, surface preparation if required etc. complete.including providing & fixing Expanded Metal lathe ( B5 Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 44 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing & applying 6 ~ 8 mm thk INTERNAL SINGLE COAT CEMENT PLASTER in cement mortar 1:4 to the walls, beams, ceilings, stairs, soffits, columns, pardies, bends, moulds, pattas, grooves at all heights including scaffolding, curing. The rates are B6 inclusive including providing & fixing Expanded Metal lathe ( sq.mt. Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

TENDERER

BOQ -Page 45 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 405 109 134 401 119 119 119 119 119 4,080

RATE

AMOUNT

B7 Providing and applying neat smooth finish Cement Gothai for Trenchs sq.mt. For Basement Total of Section B SECTION-C WATERPROOFING

Providing and laying cement based TERRACE WATERPROOFING TREATMENT of approved agency & C1 specifications covering 10 years performance guarantee on stamp paper complete as directed. Clean the surface for treatment by removing dust, dirt and layers of concre Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 10 over the side parapet walls. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide 115 mm thick (average) graded B.B.C The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. compl
For BASEMENT For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO 717 1,109 2,558 471 774 774 495 137

TENDERER

BOQ -Page 46 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and doing waterproofing treatment including upto 200 mm fill for TOILET SLAB, and other sunken areas. Clean the surface for C2 treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments as req Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 1.0m over the side walls. Air cure the same for 24 hours and damp cure for next 4-5 days.Provide 1:4 waterproofing plaster with waterproof a The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. comp For 'B2' Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing polymeric cement based waterproofing treatment on toilet side walls upto a height of 1000 mm above existing slab level finished smooth with appropriate slopes to receive tiles etc. and complete as per instruction given by Architect/ PMC (as per For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO 161 279 784 QRO 461 461 QRO 59 sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO 119 209 608 QRO 236 236 QRO 35

C3

TENDERER

BOQ -Page 47 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

C4

Providing polymeric cement based waterproofing treatment to U.G / O.H. TANK , OTHER WATER STORAGE UNIT'S side walls and bottom slabs of any size. Clean the RCC surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provid For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 2,737 QRO QRO QRO QRO QRO QRO QRO QRO

Providing and laying 25mm thick smooth finished metal coba in 1:1.5:3 C:S:M with waterproof and anti-shrinkage admixture C5 SUNPLEX - (330 gms per 50 kg bag of cement) and providing approved quality and quantity for chajjas, sloping roofs, balconies, flower For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 48 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
C6 Box Waterproofing

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

a)For Horizontal Surfaces Clean the PCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting treatments as required at identified locations as per specifications using non shrink cement grout slurry. Providing and laying 15 to 20mm rough finished shahabad stone with 15mm metal coba bedding mortar (1:4) with addition of SUNPLEX in 15mm gap in between stone. Filling the shahbad stone joints with Polymer Modified mortar prepared by mixing POLYALK EP : Cement : Quartz sand mixed in the weight ratio 1:5:15 as per specificaitons. Providing a neat cement sand smooth finishing layer of cement mortar in 15-20 mm thick by admixing POLYALK EP 3-5% by weight of cement to the mortar mix and curing the same. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours over the smooth surface. Air cure the same for 24 hours and damp cure for next 4-5 days Providing and laying 20-25 mm cement mortar over the coating in CM 1:4 with addition of SUNPLEX (330 gms pouch) per 50 kgs bag of cement.

sq.mt.

10,926

b) For vertical surfaces Clean the RCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting sq.mt. treatments as required at identified locations as per specifications using non shrink cement grout slurry. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide over the coating 1:4 waterproofing plaster in 20-25 mm thickness in double coat with Providing and applying non shrink cement grouting under pressure using cement grouting pump at the junctions of horizontal and vertical RCC surface mixing SUNPELX - 2 pouches per 50 kgs bag of cement at 2.0" c/c by drilling holes and inserting PVC nozzles

7,141

TENDERER

BOQ -Page 49 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing polymeric cement based waterproofing treatment to walls and floors of flower beds, landscape areas etc. Clean the RCC C7 sq.mt. surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments a For Basement Providing and applying CRYSTALINE chemical waterproofing treatment with POLYALK WCR in two coats by mixing it with water in C8 the ratio 1:0.3-0.4 and applying the same by brush on the clean RCC surface as per instruction from the consultant / PMC for Baseme For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Total of Section C SECTION - D FLOORING Providing and laying in flooring Chequred tiles of approved make, colour and pattern on a bedding of 1:4 cement mortar including neat D1 cement float, giving proper slopes, compaction, curing and finishing over bedding Brick Bat Coba complete as directed For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 546 255 261 632 67 97 97 80 QRO

TENDERER

BOQ -Page 50 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and laying in required position flooring and curbing of Broken China Mosaic of approve colour and pattern on a bedding of D2 1:4 cement mortarincluding neat cement float, giving proper siopes, compaction, curing and finishing over bedding Brick Bat For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing, machine mixing and laying 50-75 mm thick Indian Patent Stone floor ( IPS) on the P.C.C/ R.C.C. surface in approved panels D3 sizes, in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 12.5 mm thick) with 7 mm thick plaster in CM 1:4 we For Basement sq.mt. 350 sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO

Providing and laying 25-32mm thick machine cut and machine polished green kotah stone flooring square or D4 rectangular sizes as per drawing or as directed and of approved colour and shade including 20mm thick 1:6 cement mortar bedding, to be compacted prope For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and laying 19mm thick Machine cut and machine polished Kota stone 150mm high Skriting with in 1:4 D5 cement mortar bedding/back coat of 20mm thick, machine polished ground, as per detailed drawings, filling joints with cement slurry, curing, h

sq.m

sq.m sq.m sq.m sq.m sq.m sq.m sq.m sq.m sq.m

1,370 86 165 487 111 194 194 111 QRO

r.m

TENDERER

BOQ -Page 51 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
r.m r.m r.m r.m r.m r.m r.m r.m r.m

RATE

AMOUNT

775 98 172 465 155 199 199 155 QRO

Supply and fixing factory made precast concrete interlocking paver blocks of approved pattern including fixing by surface dressing and D6 levelling in line with 50 mm thick sand bedding. ( Compacting with plate compactor and cutting the paver blocks wit For Basement sq.mt. 715

Supplying and fixing precast kerb stones of M20 grade concrete of size 150mm x 300mm x 400mm including fixing, necessary D7 excavation in asphaltic road, soil and embedding the same in PCC M 15/20 and filling the joints with necessary cement mortar (1:4) cur For Basement r.m. 597

Providing & laying 150mm thick M-20 grade concrete Trimix flooring with nominal reinforcement 8mm dia or steel at 300 mm c/c both D8 ways on well completed PCC sub-base. The concrete shall consist of 325 Kg of cement per cubic meter of concrete shall be pour For Basement D9 Finishing the basement slabs during concreting using Powerfloat sq.mt. sq.mt. QRO QRO

D10

Providing and fixing 20mm thick machine cut, machine polished granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. ( Basic R For Basement sq.m QRO

Providing and fixing 20mm thick machine cut, Flamed granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , D11 joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. For Basement sq.m Providing and fixing precast reinforced concrete cable / strom water trench covers of 150mm thk, upto 450 mm wide. etc. of M20 grade including reinforcement etc and M.S. angles fixing arrangement, etc complete of approved sample.

QRO

D12

TENDERER

BOQ -Page 52 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For Basement

DESCRIPTION
Total of Section D SECTION-E PAINTING

UNIT QUANTITY
sq.mt. 1,632

RATE

AMOUNT

Providing and applying two coats of waterproof, heat insulating anti carbonation, protective coating of SUNEXT-8 E1 over the surface like external plasters, exposed concrete sq.mt. surfaces of basement side walls and soffit slabs by admixing it with water in the r
Providing and applying TEXTURE PAINT in three coats, first base primer coat & two finishing coats fo approved make and colour on the sq.mt. external walls over wire brushed and cleaned surface as per manufacturers instructions. The rates are inclusive of providi For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing applying CEMENT PAINT to newly plastered or concrete surfaces in three coats with best quality cement paint of approved make and colour by the architect. The rate includes scaffolding , curing ,etc. complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

QRO

E2

QRO QRO QRO QRO QRO QRO QRO QRO QRO

E3

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

1,357 702 815 1,549 418 559 559 418 336

E4

Providing and applying OIL BOUND DISTEMPER of approved make and colour on walls, ceilings and other surfaces over sandpapered and cleaned surface in two finishing coats over base primer coat to achieve even finish & complete as per instruction given by Ar For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 3,143 380 677 1,855 672 855 855

TENDERER

BOQ -Page 53 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
sq.mt. sq.mt. 672 QRO

RATE

AMOUNT

TENDERER

BOQ -Page 54 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
E5

DESCRIPTION
Providing and applying three coat of flat oil paint /SYNTHETIC ENAMEL of approved colour and shade to old and new surface including cleaning, preparing surface, applying primer coat, putty etc. complete as directed For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

UNIT QUANTITY

RATE

AMOUNT

sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt.

QRO QRO QRO QRO QRO QRO QRO QRO QRO

E6

Providing and applying WHITE WASH all surfaces of newly plastered surfaces and all form finished concrete surfaces which includes ceiling , drop pardies ,columns ,beams and other areas specifide by architect etc. complete togive an even shade to all surf For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 20,671 2,711 6,200 13,907 1,717 3,003 3,003 1,717 152

Providing and applying "Renovo" or "Ruff and Tuff" synthetic plaster type paint of approved shade colour and texture on external walls as E7 per manufacturers specification and finishing in 5 coats, including preparing surface and scaffolding, etc.complete For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 55 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

Providing and applying Silicone based water repelant Elastomeric coating of POLYCOAT TST on external walls E8 as per manufacturers specification including preparing surface and scaffolding, etc complete
For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. QRO QRO QRO QRO QRO QRO QRO QRO QRO

Providing and applying hygenic epoxy coating on the internal walls of tanks using SUNEPOXY 378 in three coats E9 at 24 hours interval by mixing the epoxy resin and hardener in the ratio 1:0.5 and applying the same on the clean and dry surface etc. complete t
For Basement Total of Section E sq.mt. 2,305

SECTION- F DOORS AND WINDOWS Providing and fixing Rough ground door frame of clear opening size 700-2450mm consisting of 25 X75 mm SAL F1 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/concre For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and fixing Rough ground door frame of clear opening size 800-2450mm consisting of 25 X75 mm SAL F2 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/concre For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block

NOS NOS NOS NOS NOS NOS NOS NOS NOS

38 32 40 100 15 45 45 15 5 24

NOS NOS NOS NOS NOS

QRO QRO QRO QRO QRO

TENDERER

BOQ -Page 56 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY NOS NOS NOS NOS QRO QRO QRO QRO

RATE

AMOUNT

Providing and fixing Rough ground door frame D2 of clear opening size 950-2450mm consisting of 25 X75 mm SAL F3 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/con For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and fixing Rough ground door frame D2 of clear opening size 1050-2450mm consisting of 25 X75 mm SAL F4 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

NOS NOS NOS NOS NOS NOS NOS NOS NOS

QRO QRO QRO QRO QRO 5 5 QRO QRO

NOS NOS NOS NOS NOS NOS NOS NOS NOS NOS

62 26 17 70 6 24 24 24 9 9 271

Providing and fixing Rough ground door frame D3 of clear opening size 1200-2450mm consisting of 25 X75 mm SAL F5 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

NOS NOS NOS NOS NOS NOS NOS NOS NOS

QRO QRO QRO QRO 11 21 21 11 6

Providing and fixing Rough ground door frame D3 of clear opening size 1250-2450mm consisting of 25 X75 mm SAL F6 WOOD door frame .Door frame to be treated with anti- NOS termite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements NOS For 'A' Block NOS

QRO

QRO QRO

TENDERER

BOQ -Page 57 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'B 1' Block

DESCRIPTION

UNIT QUANTITY NOS QRO

RATE

AMOUNT

TENDERER

BOQ -Page 58 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY NOS NOS NOS NOS NOS NOS QRO QRO QRO QRO QRO QRO

RATE

AMOUNT

Providing and fixing Rough ground door frame D3 of clear opening size 1550-2450mm consisting of 25 X75 mm SAL F7 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Providing and fixing Rough ground door frame D3 of clear opening size 1850-2450mm consisting of 25 X75 mm SAL F8 WOOD door frame .Door frame to be treated with antitermite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

NOS NOS NOS NOS NOS NOS NOS NOS NOS

6 QRO 2 2 QRO QRO QRO QRO QRO

NOS

QRO

NOS NOS NOS NOS NOS NOS NOS NOS NOS

QRO QRO 8 16 QRO QRO QRO QRO QRO

Providing and fixing Rough ground door frame D4 of clear opening size 2050-2450mm consisting of 25 X75 mm SAL F9 WOOD door frame .Door frame to be treated with anti- NOS termite treatment and with wood preservative at surfaces coming in contact with masonary/co For Basements For 'A' Block For 'B 1' Block For 'B 2' Block

TENDERER

BOQ -Page 59 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY 5 5 5 5 0

RATE

AMOUNT

Providing and fixing Aluminium natural anodised Sub F10 frame 25mm x 100mm as per approved profile, fixed into r.mt. Masonry / RCC surfaces prior to external plaster. For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Total of Section F
SECTION-G STEEL / METAL WORKS

QRO

Providing & fabricating, handrails including bending and welding with approved special electrodes and fixing in position hand rails G1 consisting of stainless steel hand grip rail of 50mm Dai. 16 gauge supported with combination of powder coated M.S and sta

For Basements For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

r.m r.m r.m r.m r.m r.m r.m r.m r.m

QRO QRO QRO QRO QRO QRO QRO QRO QRO

G2

Providing and fixing Perforated MS galvanized rolling shutters of minimum 18 gauge of approved make, including all fixtures and sq.mt. fastenings, GI guides, GI sheet cover, rollers, locking arrangements as directed on both sides, etc. complete in all respects o

59

For Basements
Extra for providing and fixing mechanical hand operated gear sq.mt. arrangement and providing handle of approved design, for E9 item.

G3

59

For Basements
Providing and fixing Hot Dipped Galvanised Mild Steel Corner Gaurds, 75 x75 x 6 mm thick, after manufacture, galvanising minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds end s, etc c

G4

For Basements

r.m.

QRO

TENDERER

BOQ -Page 60 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

G5

Providing and fixing High Density Rubber Corner Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 70 x70 mm , galvanising minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds end

For Basements
Providing and fixing High Density Rubber Bumper Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 200 mm wide , galvanising minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds e

r.m.

360

G6

For Basements

r.m.

300

Providing and fixing M.S. Grating of Heavy Duty type and size as per requirement for basement and other drainage covers including one G8 coat of red primer and two coats of approved colour epoxy fixed to RCC work or Masonry work with M.S. support at all ends For Basement Total of Section G SECTION-H GENERAL ITEMS Pulling down burnt brick masonry in cement mortar with plaster including sorting serviceable bricks (and stacking the same) and debris separately, disposing the debris beyond the premises or spreading as directed complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block

Kg.

QRO

H1

cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m

5 5 5 5 5 5 5 5

TENDERER

BOQ -Page 61 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
cu.m 5

RATE

AMOUNT

H2

Pulling down Cement Concrete Solid Block masonry in cement mortar with plaster including sorting serviceable bricks (and stacking the same) and debris separately, disposing the debris beyond the premises or spreading as directed complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m QRO QRO QRO QRO QRO QRO QRO QRO QRO

Dismantling reinforced cement concrete (including plaster) work including breaking concrete by chiseling, wedging etc. including H3 cutting the reinforcement, stacking the serviceable materials and the debris separately, disposing the debris beyond the prem For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Dismantling cement concrete work including breaking concrete by chiseling, wedging etc. stacking the serviceable materials and the debris separately, disposing the debris beyond the premises or spreading as directed complete. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block Disposal of earth / malba/rubbish of contractor by mechanical transport to the nearest Municipal dump complete if directed only. For Basement For 'A' Block For 'B 1' Block For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block H6 Providing and fixing Over Deck Insulation top terrace slabs cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m 30 20 20 30 20 30 30 20 10 cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m 5 5 5 5 5 5 5 5 5

H4

cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m cu.m

QRO QRO QRO QRO QRO QRO QRO QRO

H5

TENDERER

BOQ -Page 62 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For 'A' Block For 'B 1' Block

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

sq.mt.

717

TENDERER

BOQ -Page 63 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO
For 'B 2' Block For 'D 1' Block For 'D 2' Block For 'D 3' Block For 'D 4' Block For 'D 5' Block

DESCRIPTION

UNIT QUANTITY
sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. sq.mt. 1,109 471 774 774 495 137

RATE

AMOUNT

Providing antitermite treatment around the periphery of the existing building as per I.S: 6313(part iii) latest by excavating trenches of 20 H7 sq.mt. cm. width and exposing the sides of the column and plinth beams upto a depth of 300mm. And injecting chemical and

10,494

Total of Section H Total of section A to H

TENDERER

BOQ -Page 64 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL / CIVIL WORKS / REVISED TENDER BOQ/ 23G07

JULY 23' 2007

SUMMARY OF BILL OF QUANTITIES FOR CIVIL WORKS FOR 'E' BLOCK,

NO.

DESCRIPTION

AMOUNT
(In rupees)

A B C D E F G H

MASONRY WORKS PLASTERING WORKS WATERPROOFING WORKS FLOORING WORKS PAINTING WORKS DOORS AND WINDOWS STEEL AND METAL WORKS GENERAL ITEMS GRAND TOTAL (A to E)

( Rupees

Only )

TENDERER

SUMMARY - Page 65 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS ' HLL / CIVIL WORKS / REVISED TENDER BOQ/ 23G07

VOLUME II CIVIL WORKS TENDER -BOQ

BILL OF QUANTITIES FOR CIVIL WORKS FOR 'E' BLOCK, AT HLL CAMPUS, ANDHERI, MUMBAI.
SR NO

DESCRIPTION
SECTION-A MASONRY

UNIT

QUANTITY

RATE

AMOUNT

Providing and constructing 200 mm thk SOLID CEMENT CONCRETE BLOCKS masonry in CM 1:5 ( 1 cement and 5 coarse A1 sand) including with good quality locally available or site sq.mt. manufactured solid concrete blocks, having minimum strength of 70 kg./ sq.cms and wa Providing and constructing 150 mm thk SOLID CEMENT CONCRETE BLOCKS masory in CM 1:5 ( 1 cement and 5 A2 coarse sand) including with good quality locally available or site sq.mt. manufactured solid concrete blocks , having minimum strength of 70 kg./ sq.cms and Providing and constructing 200 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) A3 , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not sq.mt. more than 600 Kg/cum . ,in specified courses of approved masonry bond Providing and constructing 150 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) A4 , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not sq.mt. more than 600 Kg/cum . ,in specified courses of approved masonry bond Providing and constructing 230 mm thk Burnt Brick masory in CM 1:6 ( 1 cement and 6 coarse sand) including with good quality A5 sq.mt. locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum .by weight. ,in specified

QRO

QRO

1,632

QRO

QRO

Providing and constructing 150 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally A6 available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou For 'E' Block sq.mt. 1,741

Providing and constructing 100 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally A7 sq.mt. available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou

108

Providing and laying (second class burnt) brick masonry in 1:6 C.M , A8 above and below plinth and at all levels including for odd shaped sq.mt. walls , steps , brick fins , columns, etc. complete.

QRO

A9

Providing and constructing 200mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints sq.mt. and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete.

QRO

TENDERER

BOQ -Page 66 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

Providing and constructing 100mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints A10 sq.mt. and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete. Providing, laying and filling to required slope in toilet, W.C block with A11 siporex blocks in lime mortar, ramming compacting etc. complete cu.mt. as directed. Providing and constructing uncoursed random rubble masonry wall of local stones for foundations upto highest plinth level in CM sq.mt. 1:4, ( 1 cement, 4 coarse sand) including curing, striking off joints on wall faces, scaffolding, providing weep

QRO

62

A12

QRO

A13

Providing and fixing 150mm thick precast RCC Screen Element in 1:3:6 cement concrete with light mesh reinforcement with sharp sq.mt. finished edges as per design and drawing including 21 days curing before transportation, hoisting and fixing at site etc comple Total of Section A SECTION-B PLASTER

QRO

Providing and applying 20mm thk SAND FACE PLASTER in two coats at all heights in 15mm thk base coat of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions and finished with minimum B1 6mm thicknes including providing & fixing Expanded Metal lathe ( sq.mt. Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

2,137

Providing and applying 12mm thk EXTERNAL SAND FACED PLASTER in SINGLE coat for ducts and shafts at all height of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions on B2 all types of concrete including providing & fixing Expanded Metal sq.mt. lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

673

Providing and Applying 12mm INTERNAL SINGLE COAT CEMENT PLASTER ( scratch coat plaster / trowel finish) in cement mortar 1:4 with waterproofing compound, as base coat for cladding work, to be of rough finish, to recieve Finishing, at all heights including including B3 sq.mt. providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

5,330

TENDERER

BOQ -Page 67 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

Providing & applying GYPSUM PLASTER as per manufactureres instruction / specs with minimum 12 mm thick on walls, beams,columns , ceiling etc including jambs, cill, in perfect line and level over newly concreted RCC surfaces , C.C block masonry , B4 sq.mt. and including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

200

TENDERER

BOQ -Page 68 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

Providing Plaster of Paris finish to plastered surfaces in all positions including scaffolding, surface preparation if required etc. complete.including providing & fixing Expanded Metal lathe ( B5 Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on sq.mt. the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

QRO

Providing & applying 6 ~ 8 mm thk INTERNAL SINGLE COAT CEMENT PLASTER in cement mortar 1:4 to the walls, beams, ceilings, stairs, soffits, columns, pardies, bends, moulds, pattas, grooves at all heights including scaffolding, curing. The rates are B6 inclusive including providing & fixing Expanded Metal lathe ( sq.mt. Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

217

B8

Providing and applying neat smooth finish Cement Gothai for sq.mt. Trenchs
Total of Section B SECTION-C WATERPROOFING

QRO

Providing and laying cement based TERRACE WATERPROOFING TREATMENT of approved agency & C1 specifications covering 10 years performance guarantee on stamp paper complete as directed. Clean the surface for treatment by removing dust, dirt and layers of concre Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 10 over the side parapet walls. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide 115 mm thick (average) graded B.B.C The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. compl
For 'E' Block sq.mt. 733

TENDERER

BOQ -Page 69 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION
Providing and doing waterproofing treatment including upto 350 mm fill for TOILET SLAB, and other sunken areas. Clean the surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments as req Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 1.0m over the side walls. Air cure the same for 24 hours and damp cure for next 4-5 days.Provide 1:4 waterproofing plaster with waterproof a The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. comp For 'E' Block

UNIT

QUANTITY

RATE

AMOUNT

C2

sq.mt.

156

Providing polymeric cement based waterproofing treatment on toilet side walls upto a height of 1000 mm above existing slab level C3 sq.mt. finished smooth with appropriate slopes to receive tiles etc. and complete as per instruction given by Architect/ PMC (as per Providing polymeric cement based waterproofing treatment to U.G / O.H. TANK , OTHER WATER STORAGE UNIT'S side walls C4 and bottom slabs of any size. Clean the RCC surface for treatment sq.mt. by removing dust, dirt and layers of concrete over the slab etc. Provid

253

QRO

TENDERER

BOQ -Page 70 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

Providing and laying 25mm thick smooth finished metal coba in 1:1.5:3 C:S:M with waterproof and anti-shrinkage admixture C5 SUNPLEX - (330 gms per 50 kg bag of cement) and providing sq.mt. approved quality and quantity for chajjas, sloping roofs, balconies, flower C6 Polymeric Box Waterproofing

QRO

a)For Horizontal Surfaces Clean the PCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting treatments as required at identified locations as per specifications using non shrink cement grout slurry. Providing and laying 15 to 20mm rough finished shahabad stone with 15mm metal coba bedding mortar (1:4) with addition of SUNPLEX in 15mm gap in between stone. Filling the shahbad stone joints with Polymer Modified mortar prepared by mixing POLYALK EP : Cement : Quartz sand mixed in the weight ratio 1:5:15 as per specificaitons. Providing a neat cement sand smooth finishing layer of cement mortar in 15-20 mm thick by admixing POLYALK EP 35% by weight of cement to the mortar mix and curing the same. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours over the smooth sq.mt. surface. Air cure the same for 24 hours and damp cure for next 4-5 days Providing and laying 20-25 mm cement mortar over the coating in CM 1:4 with addition of SUNPLEX (330 gms pouch) per 50 kgs bag of cement. b) For vertical surfaces Clean the RCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting sq.mt. treatments as required at identified locations as per specifications using non shrink cement grout slurry. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide over the coating 1:4 waterproofing plaster in 20-25 mm thickness in double coat with

QRO

TENDERER

BOQ -Page 71 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION
Providing and applying non shrink cement grouting under pressure using cement grouting pump at the junctions of horizontal and vertical RCC surface mixing SUNPELX - 2 pouches per 50 kgs bag of cement at 2.0" c/c by drilling holes and inserting PVC nozzles

UNIT

QUANTITY

RATE

AMOUNT

Providing polymeric cement based waterproofing treatment to walls and floors of flower beds, landscape areas etc. Clean the RCC C7 sq.mt. surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments a Providing and applying CRYSTALINE chemical waterproofing treatment with POLYALK WCR in two coats by mixing it with water C8 in the ratio 1:0.3-0.4 and applying the same by brush on the clean sq.mt. RCC surface as per instruction from the consultant / PMC for Baseme Total of Section C SECTION - D FLOORING Providing and laying in flooring Chequred tiles of approved make, colour and pattern on a bedding of 1:4 cement mortar including neat sq.mt. cement float, giving proper slopes, compaction, curing and finishing over bedding Brick Bat Coba complete as directed

76

83

D1

QRO

Providing and laying in required position flooring and curbing of Broken China Mosaic of approve colour and pattern on a bedding of D2 sq.mt. 1:4 cement mortarincluding neat cement float, giving proper siopes, compaction, curing and finishing over bedding Brick Bat

QRO

TENDERER

BOQ -Page 72 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

D3

Providing, machine mixing and laying 50-75 mm thick Indian Patent Stone floor ( IPS) on the P.C.C/ R.C.C. surface in approved sq.mt. panels sizes, in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 12.5 mm thick) with 7 mm thick plaster in CM 1:4 we

QRO

Providing and laying 25-32mm thick machine cut and machine polished green kotah stone flooring square or rectangular D4 sizes as per drawing or as directed and of approved colour sq.m and shade including 20mm thick 1:6 cement mortar bedding, to be compacted prope Providing and laying 19mm thick Machine cut and machine polished Kota stone 150mm high Skriting with in 1:4 cement D5 mortar bedding/back coat of 20mm thick, machine polished ground, as per detailed drawings, filling joints with cement slurry, curing, h

60

r.m

70

D6

Supply and fixing factory made precast concrete interlocking paver blocks of approved pattern including fixing by surface dressing and sq.mt. levelling in line with 50 mm thick sand bedding. ( Compacting with plate compactor and cutting the paver blocks wit

QRO

D7

Supplying and fixing precast kerb stones of M20 grade concrete of size 150mm x 300mm x 400mm including fixing, necessary sq.mt. excavation in asphaltic road, soil and embedding the same in PCC M 15/20 and filling the joints with necessary cement mortar (1:4) cur

QRO

TENDERER

BOQ -Page 73 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

Providing & laying 150mm thick M-20 grade concrete Tremix flooring with nominal reinforcement 8mm dia or steel at 300 mm c/c D8 both ways on well completed PCC sub-base. The concrete shall sq.mt. consist of 325 Kg of cement per cubic meter of concrete shall be pour Providing and fixing 20mm thick machine cut, machine polished granite stone set in 20mm thick cement mortar 1:4 bedding/back sq.mt. coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. ( Basic R Providing and fixing 20mm thick machine cut, Flamed granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , sq.m joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed.

QRO

D9

QRO

D10

QRO

Providing and fixing precast reinforced concrete cable / strom water trench covers of 150mm thk, upto 450 mm wide. etc. of M20 D11 sq.mt. grade including reinforcement etc and M.S. angles fixing arrangement, etc complete of approved sample. Total of Section D SECTION-E PAINTING

QRO

Providing and applying two coats of waterproof, heat insulating anti carbonation, protective coating of SUNEXTE1 8 over the surface like external plasters, exposed concrete sq.mt. surfaces of basement side walls and soffit slabs by admixing it with water in the r
Providing and applying TEXTURE PAINT in three coats, first base primer coat & two finishing coats fo approved make and colour on the external walls over wire brushed and cleaned surface as per manufacturers instructions. The rates are inclusive of providi For 'E' Block sq.mt.

QRO

E2

QRO

TENDERER

BOQ -Page 74 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

E3

Providing applying CEMENT PAINT to newly plastered or concrete surfaces in three coats with best quality cement paint of approved make and colour by the architect. The rate includes scaffolding , curing ,etc. complete. For 'E' Block sq.mt. Providing and applying OIL BOUND DISTEMPER of approved make and colour on walls, ceilings and other surfaces over sandpapered sq.mt. and cleaned surface in two finishing coats over base primer coat to achieve even finish & complete as per instruction given by Ar For 'E' Block Providing and applying three coat of flat oil paint /SYNTHETIC ENAMEL of approved colour and shade to old and new surface sq.mt. including cleaning, preparing surface, applying primer coat, putty etc. complete as directed For 'E' Block

673

E4

290

E5

QRO

E6

Providing and applying WHITE WASH all surfaces of newly plastered surfaces and all form finished concrete surfaces which includes ceiling , drop pardies ,columns ,beams and other areas specifide by architect etc. complete togive an even shade to all surf For 'E' Block sq.mt. 4,054

E7

Providing and applying "Renovo" or "Ruff and Tuff" synthetic plaster type paint of approved shade colour and texture on external sq.mt. walls as per manufacturers specification and finishing in 5 coats, including preparing surface and scaffolding, etc.complete For 'E' Block

QRO

Providing and applying Silicone based water repelant Elastomeric coating of POLYCOAT TST on external walls E8 sq.mt. as per manufacturers specification including preparing surface and scaffolding, etc complete
For 'E' Block

QRO

Providing and applying hygenic epoxy coating on the internal walls of tanks using SUNEPOXY 378 in three coats at E9 24 hours interval by mixing the epoxy resin and hardener in sq.mt. the ratio 1:0.5 and applying the same on the clean and dry surface etc. complete t
Total of Section E

QRO

TENDERER

BOQ -Page 75 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION
SECTION- F DOORS AND WINDOWS

UNIT

QUANTITY

RATE

AMOUNT

Providing and fixing Rough ground door frame of clear opening size 650-2450mm consisting of 25 X75 mm SAL F1 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/concre Providing and fixing Rough ground door frame of clear opening size 800-2450mm consisting of 25 X75 mm SAL F2 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/concre Providing and fixing Rough ground door frame D2 of clear opening size 950-2450mm consisting of 25 X75 mm SAL F3 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/con Providing and fixing Rough ground door frame D2 of clear opening size 1050-2450mm consisting of 25 X75 mm SAL F4 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co Providing and fixing Rough ground door frame D3 of clear opening size 1200-2450mm consisting of 25 X75 mm SAL F5 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co Providing and fixing Rough ground door frame D3 of clear opening size 1250-2450mm consisting of 25 X75 mm SAL F6 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co Providing and fixing Rough ground door frame D3 of clear opening size 1550-2450mm consisting of 25 X75 mm SAL F7 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co Providing and fixing Rough ground door frame D3 of clear opening size 1850-2450mm consisting of 25 X75 mm SAL F8 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co Providing and fixing Rough ground door frame D4 of clear opening size 2050-2450mm consisting of 25 X75 mm SAL F9 WOOD door frame .Door frame to be treated with anti-termite Nos. treatment and with wood preservative at surfaces coming in contact with masonary/co

QRO

29

QRO

33

QRO

QRO

TENDERER

BOQ -Page 76 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY QRO

RATE

AMOUNT

Providing and fixing Aluminium natural anodised Sub frame F10 25mm x 100mm as per approved profile, fixed into Masonry / r.mt. RCC surfaces prior to external plaster. Total of Section F
SECTION-G STEEL / METAL WORKS Providing & fabricating, handrails including bending and welding with approved special electrodes and fixing in position hand rails consisting of stainless steel hand grip rail of 50mm Dai. 16 gauge supported with combination of powder coated M.S and sta

G1

r.m

QRO

Providing and fixing Perforated MS galvanized rolling shutters of minimum 18 gauge of approved make, including all fixtures and G2 sq.mt. fastenings, GI guides, GI sheet cover, rollers, locking arrangements as directed on both sides, etc. complete in all respects o

QRO

G3

Extra for providing and fixing mechanical hand operated gear sq.mt. arrangement and providing handle of approved design, for E9 item.

QRO

Providing and fixing Hot Dipped Galvanised Mild Steel Corner Gaurds, 75 x75 x 6 mm thick, after manufacture, galvanising G4 minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds end s, etc c

r.m

QRO

Providing and fixing High Density Rubber Corner Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 70 x70 mm , galvanising G5 minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds end

r.m

10

Providing and fixing High Density Rubber Bumper Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 200 mm wide , G6 galvanising minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds e

r.m

10

G8

Providing and fixing M.S. Grating of Heavy Duty type and size as per requirement for basement and other drainage covers including one coat of red primer and two coats of approved colour epoxy fixed to RCC work or Masonry work with M.S. support at all ends Total of Section G SECTION-H GENERAL ITEMS

Kg.

QRO

Pulling down burnt brick masonry in cement mortar with plaster including sorting serviceable bricks (and stacking the same) and H1 cu.m debris separately, disposing the debris beyond the premises or spreading as directed complete.

TENDERER

BOQ -Page 77 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT

QUANTITY

RATE

AMOUNT

H2

Pulling down Cement Concrete Solid Block masonry in cement mortar with plaster including sorting serviceable bricks (and stacking cu.m the same) and debris separately, disposing the debris beyond the premises or spreading as directed complete.

QRO

H3

Dismantling reinforced cement concrete (including plaster) work including breaking concrete by chiseling, wedging etc. including cu.m cutting the reinforcement, stacking the serviceable materials and the debris separately, disposing the debris beyond the prem

H4

Dismantling cement concrete work including breaking concrete by chiseling, wedging etc. stacking the serviceable materials and the cu.m debris separately, disposing the debris beyond the premises or spreading as directed complete. Disposal of earth / malba/rubbish of other contractor by mechanical cu.m transport to the nearest Municipal dump complete if directed only. sq.mt.

QRO

H5

20

H6 Providing and fixing Over Deck Insulation top terrace slabs

QRO

Providing antitermite treatment around the periphery of the existing building as per I.S: 6313(part iii) latest by excavating trenches of 20 H7 sq.mt. cm. width and exposing the sides of the column and plinth beams upto a depth of 300mm. And injecting chemical and Total of Section H Total of section A to H

751

TENDERER

BOQ -Page 78 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER BOQ - SUMMARY

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G 07

JULY 23' 2007

SUMMARY OF BILL OF QUANTITIES FOR CIVIL WORKS FOR 'F' BLOCKS,

NO.

DESCRIPTION

AMOUNT
(In rupees)

A B C D E F G H

MASONRY WORKS PLASTERING WORKS WATERPROOFING WORKS FLOORING WORKS PAINTING WORKS DOORS AND WINDOWS STEEL AND METAL WORKS GENERAL ITEMS GRAND TOTAL (A to H)

( Rupees

Only )

TENDERER

SUMMARY - Page 79 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

HLL CAMPUS / CIVIL WORKS / REVISED TENDER BOQ / 23G 07

JULY 23' 2007

BILL OF QUANTITIES FOR CIVIL WORKS FOR 'F' BLOCKS, AT HLL CAMPUS, ANDHERI,
SR NO

DESCRIPTION
SECTION-A MASONRY

UNIT QUANTITY

RATE

AMOUNT

A1 Providing and constructing 200 mm thk SOLID CEMENT CONCRETE BLOCKS masonry in CM 1:5 ( 1 cement and 5 coarse sand) including with good quality locally available or site manufactured solid concrete blocks, having minimum strength of 70 kg./ sq.cms and wa For 'F' Block sq.mt. A2 Providing and constructing 150 mm thk SOLID CEMENT CONCRETE BLOCKS masory in CM 1:5 ( 1 cement and 5 coarse sand) including with good quality locally available or site manufactured solid concrete blocks , having minimum strength of 70 kg./ sq.cms and For 'F' Block sq.mt. A3 Providing and constructing 200 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond For 'F' Block sq.mt.

QRO

QRO

4,676

TENDERER

BOQ -Page 80 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO A4 Providing and constructing 150 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond For 'F' Block sq.mt. QRO A5 Providing and constructing 230 mm thk Burnt Brick masory in CM 1:6 ( 1 cement and 6 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum .by weight. ,in specified For 'F' Block For 'F' Block sq.mt. sq.mt. QRO QRO

RATE

AMOUNT

A6 Providing and constructing 150 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou For 'F' Block sq.mt. A7 Providing and constructing 100 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou For 'F' Block sq.mt.

6,940

3,335

TENDERER

BOQ -Page 81 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO A8 Providing and laying (second class burnt) brick masonry in 1:6 C.M , above and below plinth and at all levels including for odd shaped walls , steps , brick fins , columns, etc. complete. For 'F' Block For 'F' Block A9 Providing and constructing 200mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete. For 'F' Block For 'F' Block A10 Providing and constructing 100mm thk. Siporex wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., complete. For 'F' Block sq.mt. QRO sq.mt. sq.mt. QRO QRO sq.mt. sq.mt. QRO QRO

RATE

AMOUNT

A11 Providing, laying and filling to required slope in toilet, W.C block with siporex blocks in lime mortar, ramming compacting etc. complete as directed. For 'F' Block cu.mt. A12 Providing and constructing uncoursed random rubble masonry wall of local stones for foundations upto highest plinth level in CM 1:4, ( 1 cement, 4 coarse sand) including curing, striking off joints on wall faces, scaffolding, providing weep For 'F' Block A13 Providing and fixing 150mm thick precast RCC Screen Element in 1:3:6 cement concrete with light mesh reinforcement with sharp finished edges as per design and drawing including 21 days curing before transportation, hoisting and fixing at site etc comple For 'F' Block Total of Section A sq.mt. cu.mt.

109

QRO

QRO

TENDERER

BOQ -Page 82 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

SECTION-B PLASTER B1 Providing and applying 20mm thk SAND FACE PLASTER in two coats at all heights in 15mm thk base coat of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions and finished with minimum 6mm thicknes including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'F' Block B2 Providing and applying 12mm thk EXTERNAL SAND FACED PLASTER in SINGLE coat for ducts and shafts at all height of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions on all types of concrete including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'F' Block B3 Providing and Applying 12mm INTERNAL SINGLE COAT CEMENT PLASTER ( scratch coat plaster / trowel finish) in cement mortar 1:4 with waterproofing compound, as base coat for cladding work, to be of rough finish, to recieve Finishing, at all heights including including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works sq.mt. 3,574 sq.mt. 6,078

For 'F' Block B4 Providing & applying GYPSUM PLASTER as per manufactureres instruction / specs with minimum 12 mm thick on walls, beams,columns , ceiling etc including jambs, cill, in perfect line and level over newly concreted RCC surfaces , C.C block masonry , and including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

sq.mt.

25,227

For 'F' Block B5 Providing Plaster of Paris finish to plastered surfaces in all positions including scaffolding, surface preparation if required etc. complete.including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

sq.mt.

QRO

TENDERER

BOQ -Page 83 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'F' Block

DESCRIPTION

UNIT QUANTITY
sq.mt. sq.mt. QRO QRO

RATE

AMOUNT

TENDERER

BOQ -Page 84 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO B6 Providing & applying 6 ~ 8 mm thk INTERNAL SINGLE COAT CEMENT PLASTER in cement mortar 1:4 to the walls, beams, ceilings, stairs, soffits, columns, pardies, bends, moulds, pattas, grooves at all heights including scaffolding, curing. The rates are inclusive including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on sq.mt. the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'F' Block

RATE

AMOUNT

sq.mt.

582

B8 Providing and applying neat smooth finish Cement Gothai for sq.mt. Trenchs For 'F' Block sq.mt. Total of Section B SECTION-C WATERPROOFING C1 Providing

QRO

and laying cement based TERRACE WATERPROOFING TREATMENT of approved agency & specifications covering 10 years performance guarantee on stamp paper complete as directed. Clean the surface for treatment by removing dust, dirt and layers of concre Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 10 over the side parapet walls. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide 115 mm thick (average) graded B.B.C The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. compl
For 'F' Block sq.mt. 1,595

TENDERER

BOQ -Page 85 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO C2 Providing and doing waterproofing treatment including upto 350 mm fill for TOILET SLAB, and other sunken areas. Clean the surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments as req Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 1.0m over the side walls. Air cure the same for 24 hours and damp cure for next 4-5 days.Provide 1:4 waterproofing plaster with waterproof a The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. comp For 'F' Block C3 Providing polymeric cement based waterproofing treatment on toilet side walls upto a height of 1000 mm above existing slab level finished smooth with appropriate slopes to receive tiles etc. and complete as per instruction given by Architect/ PMC (as per For 'F' Block sq.mt. 1,597 sq.mt. 727

RATE

AMOUNT

C4 Providing polymeric cement based waterproofing treatment to U.G / O.H. TANK , OTHER WATER STORAGE UNIT'S side walls and bottom slabs of any size. Clean the RCC surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provid For 'F' Block sq.mt.

QRO

TENDERER

BOQ -Page 86 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO C5 Providing and laying 25mm thick smooth finished metal coba in 1:1.5:3 C:S:M with waterproof and anti-shrinkage admixture SUNPLEX - (330 gms per 50 kg bag of cement) and providing approved quality and quantity for chajjas, sloping roofs, balconies, flower For 'F' Block sq.mt. QRO C6 Polymeric Box Waterproofing

RATE

AMOUNT

a)For Horizontal Surfaces Clean the PCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting treatments as required at identified locations as per specifications using non shrink cement grout slurry. sq.mt. Providing and laying 15 to 20mm rough finished shahabad stone with 15mm metal coba bedding mortar (1:4) with addition of SUNPLEX in 15mm gap in between stone. Filling the shahbad stone joints with Polymer Modified mortar prepared by mixing POLYALK EP : Cement : Quartz sand mixed in the weight ratio 1:5:15 as per specificaitons. Providing a neat cement sand smooth finishing layer of cement mortar in 15-20 mm thick by admixing POLYALK EP 35% by weight of cement to the mortar mix and curing the same. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours over the smooth surface. Air cure the same for 24 hours and damp cure for next 4-5 days Providing and laying 20-25 mm cement mortar over the coating in CM 1:4 with addition of SUNPLEX (330 gms pouch) per 50 kgs bag of cement. b) For vertical surfaces Clean the RCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting sq.mt. treatments as required at identified locations as per specifications using non shrink cement grout slurry. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide over the coating 1:4 waterproofing plaster in 20-25 mm thickness in double coat with

QRO

TENDERER

BOQ -Page 87 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION
Providing and applying non shrink cement grouting under pressure using cement grouting pump at the junctions of horizontal and vertical RCC surface mixing SUNPELX - 2 pouches per 50 kgs bag of cement at 2.0" c/c by drilling holes and inserting PVC nozzles

UNIT QUANTITY

RATE

AMOUNT

C7 Providing polymeric cement based waterproofing treatment to walls and floors of flower beds, landscape areas etc. Clean the RCC surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments a For 'F' Block For 'F' Block C8 Providing and applying CRYSTALINE chemical waterproofing treatment with POLYALK WCR in two coats by mixing it with water in the ratio 1:0.3-0.4 and applying the same by brush on the clean RCC surface as per instruction from the consultant / PMC for Baseme For 'F' Block sq.mt. Total of Section C SECTION - D FLOORING D1 Providing and laying in flooring Chequred tiles of approved make, colour and pattern on a bedding of 1:4 cement mortar including neat cement float, giving proper slopes, compaction, curing and finishing over bedding Brick Bat Coba complete as directed For 'F' Block sq.mt. QRO

767

TENDERER

BOQ -Page 88 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO D2 Providing and laying in required position flooring and curbing of Broken China Mosaic of approve colour and pattern on a bedding of 1:4 cement mortarincluding neat cement float, giving proper siopes, compaction, curing and finishing over bedding Brick Bat For 'F' Block D3 Providing, machine mixing and laying 50-75 mm thick Indian Patent Stone floor ( IPS) on the P.C.C/ R.C.C. surface in approved panels sizes, in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 12.5 mm thick) with 7 mm thick plaster in CM 1:4 we For 'F' Block sq.mt. 1,595

RATE

AMOUNT

D4 Providing and laying 25-32mm thick machine cut and machine polished green kotah stone flooring square or rectangular sizes as per drawing or as directed and of approved colour sq.m and shade including 20mm thick 1:6 cement mortar bedding, to be compacted prope
For 'F' Block sq.m

126

D5 Providing and laying 19mm thick Machine cut and machine polished Kota stone 150mm high Skriting with in 1:4 cement mortar bedding/back coat of 20mm thick, machine polished ground, as per detailed drawings, filling joints with cement slurry, curing, h
For 'F' Block D6 Supply and fixing factory made precast concrete interlocking paver blocks of approved pattern including fixing by surface dressing and levelling in line with 50 mm thick sand bedding. ( Compacting with plate compactor and cutting the paver blocks wit For 'F' Block

r.m

r.m

117

sq.mt.

QRO

TENDERER

BOQ -Page 89 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY DESCRIPTION NO D7 Supplying and fixing precast kerb stones of M20 grade concrete of size 150mm x 300mm x 400mm including fixing, necessary excavation in asphaltic road, soil and embedding the same in PCC M 15/20 and filling the joints with necessary cement mortar (1:4) cur For 'F' Block sq.mt.

RATE

AMOUNT

QRO

D8 Providing & laying 150mm thick M-20 grade concrete Tremix flooring with nominal reinforcement 8mm dia or steel at 300 mm c/c both ways on well completed PCC sub-base. The concrete shall consist of 325 Kg of cement per cubic meter of concrete shall be pour For 'F' Block sq.mt. D9 Providing and fixing 20mm thick machine cut, machine polished granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. ( Basic R For 'F' Block sq.mt.

QRO

QRO

D10 Providing and fixing 20mm thick machine cut, Flamed granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. For 'F' Block sq.m D11 Providing and fixing precast reinforced concrete cable / strom water trench covers of 150mm thk, upto 450 mm wide. etc. of M20 grade including reinforcement etc and M.S. angles fixing arrangement, etc complete of approved sample. For 'F' Block sq.m Total of Section D SECTION-E PAINTING E1

QRO

QRO

Providing and applying two coats of waterproof, heat insulating anti carbonation, protective coating of SUNEXT-8 over the surface like external plasters, exposed concrete sq.mt. surfaces of basement side walls and soffit slabs by admixing it with water in the r
Providing and applying TEXTURE PAINT in three coats, first base primer coat & two finishing coats fo approved make and colour on the external walls over wire brushed and cleaned surface as per manufacturers instructions. The rates are inclusive of providi For 'F' Block sq.mt.

QRO

E1

QRO

E2

Providing applying CEMENT PAINT to newly plastered or concrete surfaces in three coats with best quality cement paint of approved make and colour by the architect. The rate includes scaffolding , curing ,etc. complete. For 'F' Block sq.mt.

3,574

TENDERER

BOQ -Page 90 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR UNIT QUANTITY RATE AMOUNT DESCRIPTION NO E3 Providing and applying OIL BOUND DISTEMPER of approved make and colour on walls, ceilings and other surfaces over sandpapered and cleaned surface in two finishing coats over HAVE base TO CATCH STAIRCASE PLASTER primer coat to achieve even finish & complete as per instruction given by Ar For 'F' Block 395 sq.mt. E4 Providing and applying three coat of flat oil paint /SYNTHETIC ENAMEL of approved colour and shade to old and new surface including cleaning, preparing surface, applying primer coat, putty etc. complete as directed For 'F' Block sq.mt. Providing and applying WHITE WASH all surfaces of newly plastered surfaces and all form finished concrete surfaces which includes ceiling , drop pardies ,columns ,beams and other areas specifide by architect etc. complete togive an even shade to all surf 10,626

QRO

E5

For 'F' Block sq.mt. E6 Providing and applying "Renovo" or "Ruff and Tuff" synthetic plaster type paint of approved shade colour and texture on external walls as per manufacturers specification and finishing in 5 coats, including preparing surface and scaffolding, etc.complete For 'F' Block E7 Providing and applying Silicone based water repelant sq.mt.

QRO

Elastomeric coating of POLYCOAT TST on external walls as per manufacturers specification including preparing surface and scaffolding, etc complete
For 'F' Block sq.mt. QRO

E9 Providing and applying hygenic epoxy coating on the internal walls of tanks using SUNEPOXY 378 in three coats at 24 hours interval by mixing the epoxy resin and hardener in sq.mt. the ratio 1:0.5 and applying the same on the clean and dry surface etc. complete t
Total of Section E

QRO

TENDERER

BOQ -Page 91 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION
SECTION- F DOORS AND WINDOWS

UNIT QUANTITY

RATE

AMOUNT

F1 Providing and fixing Rough ground door frame of clear opening size 650-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/concre
For 'F' Block Nos. QRO

F2 Providing and fixing Rough ground door frame of clear opening size750-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/concret
For 'F' Block Nos. 177

F3 Providing and fixing Rough ground door frame D2 of clear opening size 950-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite NOS treatment and with wood preservative at surfaces coming in contact with masonary/con
For 'F' Block Nos. 10

F4 Providing and fixing Rough ground door frame D2 of clear opening size 1050-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. 230

F5 Providing and fixing Rough ground door frame D3 of clear opening size 1200-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. QRO

F6 Providing and fixing Rough ground door frame D3 of clear opening size 1250-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. 14

F7 Providing and fixing Rough ground door frame D3 of clear opening size 1550-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. 16

TENDERER

BOQ -Page 92 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

F8 Providing and fixing Rough ground door frame D3 of clear opening size 1850-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. QRO

TENDERER

BOQ -Page 93 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

F9 Providing and fixing Rough ground door frame D4 of clear opening size 2050-2450mm consisting of 25 X75 mm SAL WOOD door frame .Door frame to be treated with anti-termite treatment and with wood preservative at surfaces coming in contact with masonary/co
For 'F' Block Nos. 5

F10 Providing and fixing Aluminium natural anodised Sub frame 25mm x 100mm as per approved profile, fixed into Masonry / RCC surfaces prior to external plaster.
For 'F' Block

r.mt.

QRO

Total of Section F
SECTION-G STEEL / METAL WORKS G1 Providing & fabricating, handrails including bending and welding with approved special electrodes and fixing in position hand rails consisting of stainless steel hand grip rail of 50mm Dai. 16 gauge supported with combination of powder coated M.S and sta For 'F' Block G2 Providing and fixing Perforated MS galvanized rolling shutters of minimum 18 gauge of approved make, including all fixtures and fastenings, GI guides, GI sheet cover, rollers, locking arrangements as directed on both sides, etc. complete in all respects o For 'F' Block G3 Extra for providing and fixing mechanical hand operated gear arrangement and providing handle of approved design, for E9 item. For 'F' Block sq.mt. 15 sq.mt. 15 r.m QRO

G4 Providing and fixing Hot Dipped Galvanised Mild Steel Corner Gaurds, 75 x75 x 6 mm thick, after manufacture, galvanising minimum coating 610 gms / sq.m, including all necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds end s, etc c For 'F' Block r.m QRO

TENDERER

BOQ -Page 94 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

G5 Providing and fixing High Density Rubber Corner Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 70 x70 mm , galvanising minimum coating 610 gms / sq.m, including all necessary blots, sq.mt. welds, ends, joints, cuts, angles, intersections, stoppeds end For 'F' Block r.m QRO

G6 Providing and fixing High Density Rubber Bumper Guards fixed to Hot Dipped Galvanised Mild Steel clamps, 200 mm wide , galvanising minimum coating 610 gms / sq.m, including all sq.mt. necessary blots, welds, ends, joints, cuts, angles, intersections, stoppeds e For 'F' Block r.m

QRO

G8 Providing and fixing M.S. Grating of Heavy Duty type and size as per requirement for basement and other drainage covers including one coat of red primer and two coats of approved colour epoxy fixed to RCC work or Masonry work with M.S. support at all ends For 'F' Block Total of Section G SECTION-H GENERAL ITEMS H1 Pulling down burnt brick masonry in cement mortar with plaster including sorting serviceable bricks (and stacking the same) and cu.m debris separately, disposing the debris beyond the premises or spreading as directed complete. For 'F' Block H2 Pulling down Cement Concrete Solid Block masonry in cement mortar with plaster including sorting serviceable bricks (and stacking the same) and debris separately, disposing the debris cu.m beyond the premises or spreading as directed complete. For 'F' Block H3 Dismantling reinforced cement concrete (including plaster) work including breaking concrete by chiseling, wedging etc. including cutting the reinforcement, stacking the serviceable materials and the cu.m debris separately, disposing the debris beyond the prem For 'F' Block H4 Dismantling cement concrete work including breaking concrete by chiseling, wedging etc. stacking the serviceable materials and the cu.m debris separately, disposing the debris beyond the premises or spreading as directed complete. For 'F' Block H5 Disposal of earth / malba/rubbish of other contractor by mechanical transport to the nearest Municipal dump complete if directed only. cu.m Kg. QRO

QRO

QRO

50

TENDERER

BOQ -Page 95 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED ' HLL CAMPUS '

VOLUME II CIVIL WORKS TENDER -BOQ

SR NO For 'F' Block

DESCRIPTION

UNIT QUANTITY

RATE

AMOUNT

H6 Providing and fixing Over Deck Insulation top terrace slabs For 'F' Block

sq.mt. sq.mt.

QRO QRO

H7 Providing antitermite treatment around the periphery of the existing building as per I.S: 6313(part iii) latest by excavating trenches of 20 cm. width and exposing the sides of the column and plinth beams sq.mt. upto a depth of 300mm. And injecting chemical and

1,340

Total of Section H Total of section A to H

TENDERER

BOQ -Page 96 of 106

CLIENT

HINDUSTAN LEVER LIMITED, PROPOSED 'HLL CAMPUS'

VOLUME II CIVIL WORKS TENDER BOQ-SUMMARY

HLL / CIVIL WORKS / TENDER BOQ/ 23G07

JULY 23' 2007

SUMMARY OF BILL OF QUANTITIES FOR CIVIL WORKS FOR 'G' BLOCKS,

NO.

DESCRIPTION

AMOUNT
(In rupees)

A B C D E

MASONRY WORKS PLASTERING WORKS WATERPROOFING WORKS FLOORING WORKS PAINTING WORKS

GRAND TOTAL (A to E)

( Rupees

Only )

TENDERER

SUMMARY 97 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

HLL / CIVIL WORKS / TENDER BOQ/ 23G07

JULY 23' 2007

BILL OF QUANTITIES FOR CIVIL WORKS FOR 'G' BLOCKS, AT HLL CAMPUS, ANDHERI, MUMBAI.
SR NO

DESCRIPTION
SECTION-A MASONRY

UNIT

QUANTITY

RATE

AMOUNT

A1 Providing and constructing 200 mm thk SOLID CEMENT CONCRETE BLOCKS masonry in CM 1:5 ( 1 cement and 5 coarse sand) including with good quality locally available or site manufactured solid concrete blocks, having minimum strength of 70 kg./ sq.cms and wa For 'G' Block sq.mt. A2 Providing and constructing 150 mm thk SOLID CEMENT CONCRETE BLOCKS masory in CM 1:5 ( 1 cement and 5 coarse sand) including with good quality locally available or site manufactured solid concrete blocks , having minimum strength of 70 kg./ sq.cms and

QRO

For 'G' Block A3 Providing and constructing 200 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond

sq.mt.

1,778

For 'G' Block

sq.mt.

QRO

A4 Providing and constructing 150 mm thk Autoclaved Aerated Concrete Block masonry in CM 1:5 ( 1 cement and 5 coarse sand) , having minimum strength of 3 n/sq.mm. and Normal Dry Desity not more than 600 Kg/cum . ,in specified courses of approved masonry bond For 'G' Block sq.mt. A5 Providing and constructing 230 mm thk Burnt Brick masory in CM 1:6 ( 1 cement and 6 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum .by weight. ,in specified For 'G' Block sq.mt.

QRO

QRO

TENDERER

SUMMARY 98 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO A6 Providing and constructing 150 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou

QUANTITY

RATE

AMOUNT

For 'G' Block A7 Providing and constructing 100 mm thk Burnt Brick masory in CM 1:4 (1 cement and 4 coarse sand) including with good quality locally available BRICKS , having minimum strength of 35 kg./ sq.cms and water absobtion 10% maximum by weight, in specified cou

sq.mt.

QRO

For 'G' Block

sq.mt.

QRO

A8 Providing and laying (second class burnt) brick masonry in 1:6 C.M , above and below plinth and at all levels including for odd shaped walls , steps , brick fins , columns, etc. complete. For 'G' Block sq.mt. A9 Providing and constructing 200mm thk. Siporex / Aracon wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., For 'G' Block A10 Providing and constructing 100mm thk. Siporex / Aracon wall in partitions in superstructure in CM 1:4, including scaffolding, raking out of joints and providing 75mm thk RCC stiffeners with reinforcement of 2 nos. 6mm dia bars at every 1000mm level etc., For 'G' Block sq.mt. sq.mt.

61

QRO

A11 Providing, laying and filling to required slopewith siporex / Aracon blocks in lime mortar, ramming compacting etc. complete as directed. For 'G' Block cu.mt. A12 Providing and constructing uncoursed random rubble masonry wall of local stones for foundations upto highest plinth level in CM 1:4, ( 1 cement, 4 coarse sand) including curing, striking off joints on wall faces, scaffolding, providing weep holes etc. c For 'G' Block cu.mt.

687

QRO

TENDERER

SUMMARY 99 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO A13 Providing and fixing 150mm thick precast RCC Screen Element in 1:3:6 cement concrete with light mesh reinforcement with sharp finished edges as per design and drawing including 21 days curing before transportation, hoisting and fixing at site etc comple For 'G' Block sq.mt.

QUANTITY

RATE

AMOUNT

QRO

C8 Filling in plinth with approved excavated materials including watering, consolidating in layers not exceeding 200mm with approved cu.mt. equipment's etc. complete as directed. Total of Section A SECTION-B PLASTER B1 Providing and applying 20mm thk SAND FACE PLASTER in two coats at all heights in 15mm thk base coat of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions and finished with minimum 6mm thicknes including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'G' Block B2 Providing and applying 12mm thk EXTERNAL SAND FACED PLASTER in SINGLE coat for ducts and shafts at all height of cement mortar (1:4) mixed with water proofing compound of Impermo or equivalent make as per manufacturers instructions on all types of concrete including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works sq.mt.

777

1,778

For 'G' Block B3 Providing and Applying 12mm INTERNAL SINGLE COAT CEMENT PLASTER ( scratch coat plaster / trowel finish) in cement mortar 1:4 with waterproofing compound, as base coat for cladding work, to be of rough finish, to recieve Finishing, at all heights including including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works For 'G' Block B4 Providing & applying GYPSUM PLASTER as per manufactureres instruction / specs with minimum 12 mm thick on walls, beams,columns , ceiling etc including jambs, cill, in perfect line and level over newly concreted RCC surfaces , C.C block masonry , and including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works

sq.mt.

122

sq.mt.

QRO

For 'G' Block

sq.mt.

QRO

TENDERER

SUMMARY 100 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO B5 Providing Plaster of Paris finish to plastered surfaces in all positions including scaffolding, surface preparation if required etc. complete.including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on sq.mt. the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by works B6 Providing & applying 6 ~ 8 mm thk INTERNAL SINGLE COAT CEMENT PLASTER in cement mortar 1:4 to the walls, beams, ceilings, stairs, soffits, columns, pardies, bends, moulds, pattas, grooves at all heights including scaffolding, curing. The rates are inclusive including providing & fixing Expanded Metal lathe ( Chickenm Mesh) (28 S.W.G) stretched taut and fixed with Nails on the surface at the junction of masonry and R.C.C. work with at least 15 cm overlap wherever required, for reinforcing plaster with all by For 'G' Block sq.mt.

QUANTITY

RATE

AMOUNT

QRO

QRO

B8 Providing and applying neat smooth finish Cement Gothai for Trenchs For 'G' Block Total of Section B SECTION-C WATERPROOFING C1 Providing sq.mt. QRO

and laying cement based TERRACE WATERPROOFING TREATMENT of approved agency & specifications covering 10 years performance guarantee on stamp paper complete as directed. Clean the surface for treatment by removing dust, dirt and layers of concre

Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 10 over the side parapet walls. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide 115 mm thick (average) graded B.B.C

The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. compl
For 'G' Block C2 Providing and doing waterproofing treatment including upto 350 mm fill for TOILET SLAB, and other sunken areas. Clean the surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments as req sq.mt. 47

TENDERER

SUMMARY 101 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR NO

DESCRIPTION
Provide and apply two coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours extending it upto 1.0m over the side walls. Air cure the same for 24 hours and damp cure for next 4-5 days.Provide 1:4 waterproofing plaster with waterproof a The rate to include cleaning, treatment to RCC slab, non shrink cement slurry grouting wherever required, providing and applying two coats of POLYALK WP, providing BBC coba and finishing with smooth top finished mortar to slope, curing, ponding etc. comp For 'G' Block

UNIT

QUANTITY

RATE

AMOUNT

sq.mt.

QRO

C3 Providing polymeric cement based waterproofing treatment on toilet side walls upto a height of 1000 mm above existing slab level finished smooth with appropriate slopes to receive tiles etc. and complete as per instruction given by Architect/ PMC (as per For 'G' Block C4 Providing polymeric cement based waterproofing treatment to U.G / O.H. TANK , OTHER WATER STORAGE UNIT'S side walls and bottom slabs of any size. Clean the RCC surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provid sq.mt. QRO

For 'G' Block

sq.mt.

QRO

C5 Providing and laying 25mm thick smooth finished metal coba in 1:1.5:3 C:S:M with waterproof and anti-shrinkage admixture SUNPLEX - (330 gms per 50 kg bag of cement) and providing approved quality and quantity for chajjas, sloping roofs, balconies, flower For 'G' Block sq.mt. C6 Polymeric Box Waterproofing sq.mt. a)For Horizontal Surfaces Clean the PCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting treatments as required at identified locations as per specifications using non shrink cement grout slurry. Providing and laying 15 to 20mm rough finished shahabad stone with 15mm metal coba bedding mortar (1:4) with addition of SUNPLEX in 15mm gap in between stone. Filling the shahbad stone joints with Polymer Modified mortar prepared by mixing POLYALK EP : Cement : Quartz sand mixed in the weight ratio 1:5:15 as per specificaitons.

QRO

QRO

Providing a neat cement sand smooth finishing layer of cement mortar in 15-20 mm thick by admixing POLYALK EP 35% by weight of cement to the mortar mix and curing the same.

TENDERER

SUMMARY 102 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR NO

DESCRIPTION
Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours over the smooth surface. Air cure the same for 24 hours and damp cure for next 4-5 days Providing and laying 20-25 mm cement mortar over the coating in CM 1:4 with addition of SUNPLEX (330 gms pouch) per 50 kgs bag of cement.

UNIT

QUANTITY

RATE

AMOUNT

sq.mt. b) For vertical surfaces Clean the RCC surface for treatment by removing dust, dirt and layers of concrete etc. Provide necessary grouting treatments as required at identified locations as per specifications using non shrink cement grout slurry. Provide and apply three coats of POLYALK WP and cement in 1:1.25 ratio at an interval of 24 hours. Air cure the same for 24 hours and damp cure for next 4-5 days. Provide over the coating 1:4 waterproofing plaster in 20-25 mm thickness in double coat with Providing and applying non shrink cement grouting under pressure using cement grouting pump at the junctions of horizontal and vertical RCC surface mixing SUNPELX - 2 pouches per 50 kgs bag of cement at 2.0" c/c by drilling holes and inserting PVC nozzles C7 Providing polymeric cement based waterproofing treatment to walls and floors of flower beds, landscape areas etc. Clean the RCC surface for treatment by removing dust, dirt and layers of concrete over the slab etc. Provide necessary grouting treatments a

QRO

For 'G' Block C8 Providing and applying CRYSTALINE chemical waterproofing treatment with POLYALK WCR in two coats by mixing it with water in the ratio 1:0.3-0.4 and applying the same by brush on the clean RCC surface as per instruction from the consultant / PMC for Baseme For 'G' Block C9 Membrane waterproofing Total of Section C SECTION - D FLOORING D1 Providing and laying in flooring Chequred tiles of approved make, colour and pattern on a bedding of 1:4 cement mortar including neat cement float, giving proper slopes, compaction, curing and finishing over bedding Brick Bat Coba complete as directed For 'G' Block

sq.mt.

QRO

sq.mt. sq.mt.

5,007 3,880

sq.mt.

QRO

TENDERER

SUMMARY 103 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO D2 Providing and laying in required position flooring and curbing of Broken China Mosaic of approve colour and pattern on a bedding of 1:4 cement mortarincluding neat cement float, giving proper siopes, compaction, curing and finishing over bedding Brick Bat For 'G' Block D3 Providing, machine mixing and laying 50-75 mm thick Indian Patent Stone floor ( IPS) on the P.C.C/ R.C.C. surface in approved panels sizes, in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 12.5 mm thick) with 7 mm thick plaster in CM 1:4 we sq.mt.

QUANTITY

RATE

AMOUNT

QRO

For 'G' Block

D4 Providing and laying 25-32mm thick machine cut and machine polished green kotah stone flooring square or rectangular sizes as per drawing or as directed and of approved colour and shade including 20mm thick 1:6 cement mortar bedding, to be compacted prope

For 'G' Block

sq.m

QRO

D5 Providing and laying 19mm thick Machine cut and machine polished Kota stone 150mm high Skriting with in 1:4 cement mortar bedding/back coat of 20mm thick, machine polished ground, as per detailed drawings, filling joints with cement slurry, curing, h
For 'G' Block D6 Supply and fixing factory made precast concrete interlocking paver blocks of approved pattern including fixing by surface dressing and levelling in line with 50 mm thick sand bedding. ( Compacting with plate compactor and cutting the paver blocks wit For 'G' Block D7 Supplying and fixing precast kerb stones of M20 grade concrete of size 150mm x 300mm x 400mm including fixing, necessary excavation in asphaltic road, soil and embedding the same in PCC M 15/20 and filling the joints with necessary cement mortar (1:4) cur For 'G' Block sq.mt. sq.mt. r.m

QRO

QRO

QRO

TENDERER

SUMMARY 104 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO D8 Providing & laying 150mm thick M-20 grade concrete Tremix flooring with nominal reinforcement 8mm dia or steel at 300 mm c/c both ways on well completed PCC sub-base. The concrete shall consist of 325 Kg of cement per cubic meter of concrete shall be pour

QUANTITY

RATE

AMOUNT

For 'G' Block D9 Providing and fixing 20mm thick machine cut, machine polished granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. ( Basic R For 'G' Block D10 Providing and fixing 20mm thick machine cut, Flamed granite stone set in 20mm thick cement mortar 1:4 bedding/back coat plaster , joints finished neatly with coloured cement, curing, hand polishing, cleaning etc. complete, as directed. For 'G' Block D11 Providing and fixing precast reinforced concrete cable / strom water trench covers of 150mm thk, upto 450 mm wide. etc. of M20 grade including reinforcement etc and M.S. angles fixing arrangement, etc complete of approved sample. For 'G' Block Total of Section D SECTION-E PAINTING E1

sq.mt.

QRO

sq.mt.

QRO

sq.m

QRO

sq.m

QRO

Providing and applying two coats of waterproof, heat insulating anti carbonation, protective coating of SUNEXT-8 over the surface like external plasters, exposed concrete sq.mt. surfaces of basement side walls and soffit slabs by admixing it with water in the r
Providing and applying TEXTURE PAINT in three coats, first base primer coat & two finishing coats fo approved make and colour on the external walls over wire brushed and cleaned surface as per manufacturers instructions. The rates are inclusive of providi

QRO

E1

For 'G' Block E2

sq.mt.

QRO

Providing applying CEMENT PAINT to newly plastered or concrete surfaces in three coats with best quality cement paint of approved make and colour by the architect. The rate includes scaffolding , curing ,etc. complete. For 'G' Block sq.mt.

QRO

TENDERER

SUMMARY 105 of 106

CLIENT

HINDUSTAN LEVER LIMITED PROPOSED 'HLL CAMPUS'.

VOLUME-II CIVIL WORKS TENDER-BOQ

SR UNIT DESCRIPTION NO E3 Providing and applying OIL BOUND DISTEMPER of approved make and colour on walls, ceilings and other surfaces over sandpapered and cleaned surface in two finishing coats over base primer coat to achieve even finish & complete as per instruction given by Ar For 'G' Block E4 sq.mt.

QUANTITY

RATE

AMOUNT

QRO

Providing and applying three coat of flat oil paint /SYNTHETIC ENAMEL of approved colour and shade to old and new surface including cleaning, preparing surface, applying primer coat, putty etc. complete as directed For 'G' Block sq.mt. Providing and applying WHITE WASH all surfaces of newly plastered surfaces and all form finished concrete surfaces which includes ceiling , drop pardies ,columns ,beams and other areas specifide by architect etc. complete togive an even shade to all surf For 'G' Block sq.mt.

QRO

E5

QRO

E6 Providing and applying "Renovo" or "Ruff and Tuff" synthetic plaster type paint of approved shade colour and texture on external walls as per manufacturers specification and finishing in 5 coats, including preparing surface and scaffolding, etc.complete For 'G' Block E7 sq.mt. QRO

Providing and applying Silicone based water repelant Elastomeric coating of POLYCOAT TST on external walls as per manufacturers specification including preparing surface and scaffolding, etc complete
For 'G' Block sq.mt. QRO

E9 Providing and applying hygenic epoxy coating on the internal walls of tanks using SUNEPOXY 378 in three coats at 24 hours interval by mixing the epoxy resin and hardener in sq.mt. the ratio 1:0.5 and applying the same on the clean and dry surface etc. complete t
Total of Section E Total of section A to E

QRO

TENDERER

SUMMARY 106 of 106

CLIENT

You might also like