PRODUCT DATA SHEET

BEKAERT

Dramix
45 65 80
l/d

R C L -80/6045 50 B N
Bright

Low Carbon

Description: Dramix

fibres are filaments of wire, deformed and cut to lengths, for reinforcement of concrete, mortar and other composite materials. Dramix RC-80/60-BN is a cold drawn wire fibre, with hooked ends, and glued in bundles.

Tensile strength:
- on the wire: minimum 1050 N/mm2 - low carbon conforms to: - DIN 17 140-D9 - low carbon conforms to: - EN 10016-2 - C9D

Coating: None Technical data:


For industrial floors, floors on vibrocompacted piles, jointless floors... ask for specialized documentation.

Applications:
- jointless floors - suspended ground slabs - jointless floors on - vibrocompacted piles - industrial floors - slabs on vibro- compacted piles

A
- liquid tight floors - overlays - pavements - segmental linings - compression layers - cellar walls - precast

1 Equivalent flexural strength


- ffctm,eq,300, ffctk,eq,300 = average and characteristic equivalent flexural strength to a deflection of 1,5 mm according to NBN B 15-238, 239, JSCE-SF4 and CUR35. - ffctm,eq,150, ffctk,eq,150 = average and characteristic equivalent flexural strength to a deflection of 3 mm according to NBN B 15-238, 239, JSCE-SF4 and CUR35.

Geometry:
Length (l) 60 mm 0,75 mm Performance class: 80 Aspect ratio (= l/d): 80 4600 fibres/kg Diameter (d)

80
45 65 80
l/d

Dramix RC-80/60-BN
Quality System in
Belgian Plants Brasilian, American and Czech Plants

Approvals:
Conforms to

fctm,fl 3,7 (1) (C20/25) (2)

4,3 (C25/30)

4,8 (C30/37)

5,3 (C35/45)

5,8 (C40/50)

Dosage ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, ffctm,eq, 300 150 300 150 300 150 300 150 300 150 20 2,1 2,5 2,8 3,2 3,5 3,7 3,9 1,9 2,3 2,7 3,0 3,3 3,4 3,5 2,4 2,9 3,3 3,6 3,8 4,0 4,2 2,3 2,7 3,1 3,3 3,5 3,6 3,7 2,8 3,2 3,6 3,9 4,2 4,3 4,4 2,6 3,0 3,3 3,6 3,9 4,0 4,1 3,0 3,5 3,9 4,2 4,4 4,6 4,8 2,8 3,2 3,5 3,8 4,1 4,2 4,3 3,2 3,7 4,1 4,4 4,6 4,8 5,0 3,0 3,3 3,6 3,9 4,2 4,3 4,4 25 30 35 40 45 50

ASTM A820
Product
Belgium

9002
Product
Russia

ATG 1857
The Netherlands

TC-07-0116-98
Poland

(1) fctm,fl = mean flexural tensile strength of plain concrete (N/mm2). (2) Concrete class corresponding with fctm,fl according to ENV 1992-1-1. (2) Boxed value [0,5] is replaced by the value 0,6 in formula (3.1). ffctk,eq,300 = 0,7 x ffctm,eq,300 ffctk,eq,150 = 0,7 x ffctm,eq,150

AT-15-2117/2001

According to Dramix guideline unless more specific data available.

1631
Turkey

Romania

015-07/012-1997
Germany

2 Equivalent axial tensile strength


- Equivalent axial tensile strength = 0,37 x equivalent flexural strength.

TS 10513

Z-71.4-3

Dramix
45 65 80
l/d Bright

R C L -80/6045 50 B N
Low Carbon

3 Stress-strain diagram
For steel fibre reinforced concrete, the following stress-strain diagram applies (symbols conform to Eurocode 2 and f Dramix guideline).
simplification
fc

Recommendations - mixing
1. General  preferably use a central batching  recommended maximum dosage:
Max. aggregate size (mm) Dosage (kg/m3) pour 60 50 35 pump 45 35 30

plant mixer

if ffct,eq,300 is not known then ffct,eq,300 is taken equal to ffct,eq,150


0,4 ffc

Ef,c,nom 10 1 0,37 ffct,eq,150 0,37 ffct,eq,300 ffct,ax if ffct,eq,300 is not known

8 16 32

 a continuous grading is preferred  mix until all glued fibres are separated into
individual fibres. Fibres dont increase mixing time significantly.  if special cements or admixtures are used, a preliminary test is recommended

4 Equivalent shear strength


The design value of the increase in shear strength due to steelwire fibres: fd (N/mm2) - (material safety factor included). The contribution of concrete and stirrups must be added to this contribution of the wire fibres.

2. Fibre addition 2.1. In batching plant mixer  never add fibres as first component  fibres can be introduced together with
sand and aggregates, or can be added in freshly mixed concrete  only for drummixer: unopened degradable bags can be thrown directly in the mixer
Graphic Team Doise, Kortrijk Resp. editor: Ann Lambrechts, Lauwe - 03/2002 (original version 05/2000)

Dramix RC-80/60-BN
fctm,fl (1) Dosage 20 25 30 35 40 45 50 3,7 (C20/25) (2)

in the mixer

fd

4,3 (C25/30)

fd

4,8 (C30/37)

fd

5,3 (C35/45)

fd

5,8 (C40/50)

fd

0,18 0,21 0,24 0,26 0,28 0,30 0,31

0,22 0,25 0,29 0,31 0,34 0,36 0,38

0,24 0,28 0,32 0,35 0,37 0,40 0,42

0,27 0,31 0,35 0,38 0,41 0,44 0,46

0,30 0,35 0,40 0,43 0,47 0,50 0,52

2.2. Truckmixer  run mixer at drum speed: 12-18 rpm  adjust slump to a min. of 12 cm
(preferably with water reducing agents or high water reducing agents)  add fibres with maximum speed of 40 kg/min  unopened degradable bags can be added provided that drum speed is min. 12 rpm  optional equipment: belt-hoist elevator  after adding the fibres, continue mixing at highest speed for 4-5 min. ( 70 rotations)

(1) fctm,fl = mean flexural tensile strength of plain concrete (N/mm2). (2) Concrete class corresponding with fctm,fl according to ENV 1992-1-1. (2) Boxed value [0,5] is replaced by the value 0,6 in formula (3.1). Please also consult the Dramix guideline

5 Toughness values
Dramix RC-80/60-BN
Dosage 15 20 25 30 35 40 45 50 Re1,5 (%) 45 56 65 74 80 86 90 94 Re3 (%) 42 52 60 68 75 80 86 90

2.3. Automatic dosing  Fibres can be dosed from bulk at rates


from 0 up to 3,5 kg/sec with a specially developed dosing equipment

Recommendations - storage
Delivered in

Values based on concrete fctm,fl = 4,8 N/mm2. To be used up to C40/50.

N.V. Bekaert S.A. - Bekaertstraat 2 - 8550 Zwevegem - Belgium Tel. +32 (0) 56 / 76 69 86 - Fax +32 (0) 56 / 76 79 47 Internet: http://www.bekaert.com/building
Values are indicative only. Modifications reserved. All details describe our products in general form only. For ordering and design only use official specifications and documents. N.V. Bekaert S.A. 2002

Protect the pallets against rain

Do not stack the pallets on top of each other

degradable bags of 20 kg on pallet 1200 kg

big bag 1100 kg

You might also like