You are on page 1of 2

NAVIGATION ECHO SOUNDER

JFE-582 200kHz / 585 50kHz


Ministry of Transport type approval Japan :JFE-582 MED Marine Equipment Directive type approval Certificate No.DERA-MED-23/00-01R:JFE-582 Certificate No.DERA-MED-16/00-01:JFE-585

Easy Easy to to see see digital digital depth depth display display Operates Operates even even when when paper paper feed feed set set to to freeze freeze

Digital Digital depth depth display, display, external external output output of of data, data, water-depth water-depth alarm alarm

Even floor floor area area ratio: ratio: -20%; -20%; mass: mass: -6kg* -6kg* Even more more compact compact main main unit unit

* * Compared Compared with with the the previous previous model model

Specifications
Range Depth Range Scale Sounding Capability Note 1 Sounding rate Operating frequency Recording Paper Paper feed speed Draft adjust Digital Depth Display Depth Alarm Power Fail Alarm Illumination Output Depth Data Input Nav.Data Output Signal Input Signal Paint Color Power Supply Dimensions Mass Operating Temperature

JFE-582JFE-585
10 0-10m 2m-10m 133times/minute

Both models confirm to IMO resolution A.224 MSC74 69Annex 4. 25 0-25m 2m-25m 50 0-50m 2m-50m 133times/minute 250 0-250m 2m-250m 66times/minute 500 0-500m 2m-500m 66times/minute

below transducer's bottom under normal propagation conditions. 133times/minute 200kHz JFE582 , 50kHz JFE585 150mm Wide 15m Long Selectable 20mm/min 10minutes , 10mm/min 20minutes , 6.6mm/min 30minutes , Freeze Note2 Max.50m 3 characters indication on the LCD. Decimal values for less than 100m. The buzzer sounds and the LED flickers when the depth is shallower than the set water depth. The buzzer sounds and the LED flickers when the power line happen to down the voltage. Note3 Recording paper and operational panel, with dimmer NMEA0183 V2.3, V1.5 , JRC format Note4 NMEA0183 V2.3, V1.5 0180, JRC format Depth Alarm Relay contact Max. 120VAC10A or 30VDC8A, selectable NONC Power Fail Alarm Relay contact Max. 120VAC10A or 30VDC8A, selectable NONC Depth Alarm acknowledge selectable contact/current drive. Rated contact 5VDC5mA, current drive 12VDC1.2mA Power Fail Alarm acknowledge selectable contact/current drive. Reted contact 24VDC5mA, current drive 12VDC1.2mA Panel:Munsell N4, Case:Munsell N7 Note5 Main Unit:100/110/115/200/220/230VAC Operationable Voltage:85-265VAC 50/60HzMax.60VA Power Fail Alarm control unit:24VDC Operationable Voltage:20-32VDC Max.2.5W when circuit is operating Wall Hanger type or Build in Flush type is all the same. W376H325.5D196mm Include the bulge of the knob W383H325.5D212mm Wall Hanger type or Build in Flush type is all the same.11kg 15-55

Note1:Set the Gain level for the best pick up of the sea bottom on the recording paper. The maximum measurable depth largely depends on the shape of the ship, installation place of the transducer, quality of the sea bottom, channel, etc., and the maximum measurable depth bottoms shallower as the ship speed becomes faster, compared with the stopping ship. Also, when the ship moves backward, the transducer is covered with a lot of bubbles generated by the screw and the sound wave is attenuated. Thus, the depth measuring function deteriorates remarkably. Note2:Set the freeze to stop the paper feed. Though the depth display and the output depth data alarms continue work. Note3:Use of the Power fail alarm capabilities requires the another power supply 24VDC. Note4:NMEA0183 output sentence, V1.5:SDDBS, SDDBT, SDDBK V2.3:SDDPT. Note5:A combination of painting colors Munsell N4 and N7 is JRC standard type.

COMPONENT
Recorder Unit Matching Box

JFE-582
Q'Ty 1 1 1 1 Mass 11kg 4kg 22kg 1kg English with cable 20m Remarks

COMPONENT
Recorder Unit Matching Box

JFE-585
Q'Ty 1 1 1 1
30.50.5

Description JFE-582 AW-154F

Description JFE-585 AW-154F-50

Mass 11kg 4kg 20kg 1kg

Remarks

Transducer Mounting NKF-341 7ZXBS0010 Spare parts Instruction Manual 7ZPBS2301C

Transducer Mounting NKF-345 7ZXBS0010 Spare parts Instruction Manual 7ZPBS2302C


30.50.5

with cable 20m English


Wall-Mounted
2601

Schematic Diagram

255.50.5

180.50.5

JFE-582/585 Recorder
250V TTYCS-1 Shipyard Water depth data output 250V TTYCS-1 Shipyard Send trigger output 250V TTYCS-1 Shipyard Water depth alarm signal output 250V TTYCS-1 Shipyard Power supply alarm signal output

Installation Diagram
334 327 400 383

Flush-Mounted

316.50.5

AW-154F/154F-50 Matching Box

7 or M6 430.50.5 8.50.5

Hole

3340.5 8.50.5 3510.5 Mounting hole dimensional drawing 15

105.50.5

0.6/1kV DPYCS-2.5 Shipyard Max.300m Transducer cable 12.9 JRC 20 250V TTYCS-1 Shipyard Water depth alarm buzzer stop signal input 250V TTYCS-1 Shipyard Power supply alarm buzzer stop signal input 250V TTYCS-1 Shipyarddata input Latitude, longitude, date, time 0.6/1kV DPYC-1.5 Shipyard24VDC power supply To power fail alarm control

Mounting hole 4-12 or M10

Max. height Mounting bolt 170

325.5

AAAAAAAA AAAAAAAAAAA AAAAAAAA AAAAAAAAAAA AAAAAAAA AAAAAAAAAAA AAAAAAAA AAAA AAAA

AAAAAAAAAAAA
AAAA AAAAAAAA AAAAAAA AAA AAAAA

AAAAAAAAAAAAAA AAAAAAAA

ECHO SOUNDER

DEPTH
ALARM ACK DEPTH ALARM SELECT SET MARK ALARM

PWR FAIL PWR PANEL

20.5

20.5

AAAAAAAAAA

312.5 319.5

Transducer

0.6/1kV DPYC-1.5 ShipyardAC power supply To main unit

OFF

22 7 16 196

Cable insertion holes 16

26 196

Cable insertion holes

376

Unit:mm

For further information, contact:

Since 1915

URL

Main Office: Akasaka Twin Tower(Main), 17-22, Akasaka 2-chome, Minato-ku, Tokyo 107-8432, JAPAN Telephone: Tokyo(03)3584-8788 Facsimile: Tokyo(03)3584-8795 Telex: 2425420 JRCTOK J Cable: JAPANRADIO TOKYO
Overseas Branches : Seattle, London Liaison Offices : Kaohsiung, Manila, Bangkok, Singapore, Jakarta, New Delhi, New York, Rotterdam, Piraeus, Las Palmas
19EM
2000.5 00.12

ISO9001 ISO14001 Certified


CAT.No.Y10-134No.434-1-3 D Printed in Japan

2751

You might also like