Batteries not included: 1609-B units require two batteries. 1609-D units require three batteries. Standard battery is 1609-SBAT. Hi-Temp Battery is 1609-HBAT.
Remote On/Off
EtherNet/IP
USB
AVR
Expandable Battery
Bulletin
1609
1609
D
Product Family
D= Deluxe (Full featured) B= Basic
600
N
VA (Volt-Amperes)
600= 600 VA 1000 = 1000 VA 1500 = 1500 VA
Voltage
N = 120VAC Input/Output
Batteries not included: 1609-B units require two batteries. 1609-D units require three batteries. Standard battery is 1609-SBAT. Hi-Temp Battery is 1609-HBAT.
Input V nom. 600N Capacity 1000N 1500N Voltage Range, default Voltage Range, widest, on line Current nom. Capacity Frequency PFC Output V nom. 600N Capacity 1000N 1500N On Line Output Range, default Output Voltage Range, widest Transfer Point Accuracy On Battery V nom. Frequency THD Short Circuit Protection Crest Factor Eciency On Battery On Line 75% (Typical with resistive load) 86% (Typical with resistive load excluding AVR mode) 2.2:1 120V (Sine Wave) 50/60Hz 0.5Hz (Factory Default: 60Hz 0.5Hz) 108~132V 108~132V 3% 120V 600VA (390 W) 1000VA (650 W) 1500VA (980 W) 120V 600VA (390 W)
Output Short On Line Output Short On Battery Thermal Protection Bypass Regulatory Safety EMC Markings Battery Pack Run Time Type Rated Capacity Charger Recharge Time Lifetime Environmental Operating Temperature Standard Battery Operating Temperature Hi Temperature Battery Storage Temperature Altitude Humidity On Line, Full load: On Line, Full load, Charging: On Battery: Full Load: 0-40C: B.B. BP5-12 0-50C: B.B. HRL5.5-12
380 Joules (Total Performance Rated With 10*1000ms Pulse) >110-130% Shutdown after 10 Seconds >130% Shutdown immediately Premises branch circuit over-current protection Shutdown UPS inside temperature 60 degree C N/A UL1778, CSA C22.2 No. 107.3-05, EN/IEC62040-1 FCC & CE (Class A) UL, cUL, FCC, CE 5 Minutes (at 25 degree C, full R load) Sealed Lead Acid Battery 12V/5.5Ah Current limited, constant voltage float charger Less than 8 hours to 90% capacity after discharged with full load 2~3 years @ 25 degree C ambient 0C~40C (32F~104F) 0C~50C (32F~122F) 0C~50C (32F~122F) - 15...45C (5F...113F) Operating 0 ... 6600 feet (0 to 2000 meters) Operating/Storage 5~95 % RH (Non-condensing) 217 BTU per hour 296 BTU per hour 1331 BTU per hour 50 dBA at front side one meter
Heat Output
Audible Noise