You are on page 1of 12

Two GE Frame 9E Power Plants for sale

2 EACH GE FRAME 9E, PG9161, MS9001

Take advantage of our current availability Financing can be arranged Priced at a fraction of new
Gas Turbines International, LLC. (GTI) is offering for sale 2 each GE PG9161 Frame 9E Power Packages. 50 HZ, 116.4 MW, each Dual Fuel, Low Hours, Complete BOP, & Includes 2 Transformers.

Visit us on our website: www.GTI-Power.com


GTIs Power Generation Services: Complete Power Plant Installations Supply, Install and Commission Operation & Maintenance Specialist Agreement for Gas Turbine and Balance of Plant Plant Rehabilitation & Relocation Training Complete Engineering & Design Capabilities Financial Strength OEM Support Refurbished and Warranted Turnkey

Date of Manufacture- 1992 Total Hours Fired- 15,000 Total Starts- 800

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001


Rated Output (Generator Terminals) MS9001 RATINGS OUTPUT- MW HEAT RATE-Kcal/kWh (LHV) HEAT RATE- Btu/kWh (LHV) MW 116.4 per Unit NATURAL GAS BASE PEAK 116.4 125.7 2608 2598 10350 10310 DISTILLATE BASE PEAK 114.2 123.3 2631 2621 10440 10400

SCOPE OF SUPPLY
Gas Turbine with essential auxiliaries, Gas Turbine Control System Generator, Starter Device and all auxiliary equipment Excitation and excitation control equipment Gas Supply line and valves from gas receiving station Gas Emergency stop valve, governor valve and actuators Gas Vent stack, Distillate supply pipeline and valves for connecting into overland supply Lubricating oil main pump AC driven pump, DC Driven pump, Jacking oil pump Lubricating oil tanks, filters, coolers and purifiers Clean oil tank and pipe work All pipework and valves for lube system Cooling water system including pumps, filters, coolers, fans, pipework and valves Air intake filters, silencer, ductwork and ancillary equipment Exhaust gas ductwork and silencer Exhaust stack, Auxiliary drive gear unit Automatic barring and inching gear Control oil supply including pumps, filters, valves, actuators and pipework Gas Generator protection equipment Plant supervisory and condition monitoring equipment Pressure, temperature, vibration and flow measuring instrumentation Local instruments, gauges, controls and panels Gas Turbine enclosure and ventilation equipment Gas Detectors and display panel Special maintenance tooling Full set of Manuals Plant drawings

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

TECHNICAL PARTICULARS GAS TURBINE GENERAL DATA


Gas Turbine Model Power Output (Generator Terminals Efficiency (Referred to Generator Terminals) Rotor Speed Direction of Rotation (looking From Generator) Number of Compressor Stages Temperature at Air Intake Atmospheric Pressure Pressure Drop up to Compressor Inlet Compressor Pressure Ratio Compressor Exhaust Temperature Compressor Efficiency Variable Geometry Stages Air Bleed-off Stages Number of Combustion Chambers Dual Fuel System Fuel Nozzles/ Combustor Ignition System Combustion Wall Temperature Fuel Consumption Method of NOx Reduction (Alternative Offer) Number of Turbine Stages Date of Manufacture Total Fired Hours Total Starts MW % RPM PG9161 116.4 33 3000 CLOCKWISE 17 15 1.013 10 11.6 343 PROPRIETARY 1 2 14 Yes 1 Spark Plug PROPRIETARY 11.4 WATER INJECTION 3 1992 15,000 800

C bar mbar C %

C Kg/S

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

GE Frame 9E Gas Turbine Plant 2 EACH GE FRAME 9E, PG9161, MS9001


OUTPUT: KVA 150625 R/MIN: 3000 VOLTS: 14000 AMPS: 6211 P.F: 0.800 PHASES/HZ: 3/50 PHASE CONN: STAR EXCITER VOLTS: 180 EXCITER AMPS: 1540 DATE: 1990 TYPE: BRUSH TURBO-GENERRATOR FRAME: BDAX9-450PRH MACHINE NO: 37694A-1G RATING: CONTINUOUS SPEC: BS 5000 PT II AMBIENT TEMP: 15.0C ALTITUDE: UP TO 1000 M COOLANT: WATER AT 24C ROTOR INSULATION: CLASS F STATOR INSULATION: CLASS F

1. 2. 3. 4. 5.

Distillate inlet. Sale will include tanks if wanted. Gas termination at fire shut off valve on the upstream side (fuel gas meters are not included). Air inlets are included Gas exhaust includes the chimneys. Electrical termination. A) 132/14KV Transformer on 132KV bushing. This allows synch on 3GO/4GO with Generator Transformer back energised. B) Essential Services Boards 1 and 2 remain allowing purchaser to take Essential Services Boards 3 & 4. C) Station Boards 1 and 2 remain allowing purchaser to take Unit Boards 3 and 4 D) Unit Transformers 3 and 4 are included in the sale.

E)

Generator Transformers 3 and 4 are included in the sale

For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

ESTIMATED PERFORMANCE GE FRAME 9E GAS TURBINE, PG9161, MS9001


BASE LOAD FUEL: NATURAL GAS MODE: SIMPLE CYCLE INLET LOSS: 8.89cm HO EXHAUST LOSS: 12.7cm HO 140 ALTITUDE A- SEA LEVEL B-500m C-1,000m D-1,500m

130 A 120

POWER OUTPUT, MEGAWATTS

B 110 C 100 D 90

80 -10 0 10 20 30 40 50

AMBIENT TEMPERATURE, deg C.


For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

ESTIMATED PERFORMANCE GE FRAME 9E GAS TURBINE, PG9161, MS9001


BASE LOAD FUEL: NATURAL GAS MODE: SIMPLE CYCLE INLET LOSS: 8.89cm HO EXHAUST LOSS: 12.7cm HO 1500 ALTITUDE A- SEA LEVEL B-500m C-1,000m D-1,500m

1400 A

HEAT CONSUMPTION, KJ/HR X 10(LHV)

1300 B 1200 C 1100

D 1000

900 -10 0 10 20 30 40 50

AMBIENT TEMPERATURE, deg C.


For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

ESTIMATED PERFORMANCE GE FRAME 9E GAS TURBINE, PG9161, MS9001


BASE LOAD FUEL: DISTILLATE MODE: SIMPLE CYCLE INLET LOSS: 8.89cm HO EXHAUST LOSS: 12.7cm HO 140 ALTITUDE A- SEA LEVEL B-500m C-1,000m D-1,500m

130

120

POWER OUTPUT, MEGAWATTS


110

B 100 C

90 D 80 -10 0 10 20 30 40 50

AMBIENT TEMPERATURE, deg C.


For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

ESTIMATED PERFORMANCE GE FRAME 9E GAS TURBINE, PG9161, MS9001


BASE LOAD FUEL: DISTILLATE MODE: SIMPLE CYCLE INLET LOSS: 8.89cm HO EXHAUST LOSS: 12.7cm HO ALTITUDE A- SEA LEVEL B-500m C-1,000m D-1,500m

1500

1400

HEAT CONSUMPTION, KJ/HR X 10(LHV)

1300 A 1200 B 1100 C 1000

9002 2

D -10 0 10 20 30 40 50

AMBIENT TEMPERATURE, deg C.


For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696

FRAME SIZE: 1. RATING Output Power Factor Voltage Frequency Speed Specification kV Hz rpm MVA

BDAX.9-450 PRH

ENCLOSURE:

CACW

150.625 at 34C cooling air 0.8 14 50 3000 BS5000 Pt.2 & IEC 34.3

2. REACTANCES to a base of 150.625MVA (Calculated) Synchronous Reactance Transient Reactance Sub-Translent Reactance Negative Sequence Reactance 3. CURVES Output/Coolant Temperature Reactive Capability Diagram Open Circuit/Short Circuit Efficiency Negative Sequence Capability Xdi X'dr X''dr X2i 230% 22% 13.4% 16.25% Issue 2 1 1 5 1

H.E.P. 7033 H.E.P. 7381 H.E.P. 7695 H.E.P. 4512 H.E.P. 7694

4. RECOMMENDED ALARM AND TRIP SETTINGS Alarm Stator Winding Temp Bearing Oil Outlet Temp C C 150 87 Trip 160 90 Exciter Air Outlet Temp C
Bearing Housing
*Vibration Peak Velocity

Alarm Trip 105 9 0.35 0.1 4 19 0.75 0.15 6

mm/sec
inches/sec

T.P.J. Metal Temp

105 105

110 -

Peak to Peak Displacement

mm

Generator Air Outlet Temp C

Shaft Relative Vibration inches X10

*If vibration is measured in terms of amplitude: Zero to peak amplitude (m)= peak velocity (mm/sec) X 9550 R.P.M. For Further Information, please contact GTI: www.GTI-Power.com Stan Green Stan@GTI-Power.com Tele: +1-312-371-9999 Larry Rayman Lray@GTI-Power.com Tele: +1-561-414-9696