You are on page 1of 4

Flexi BSC BSS parameter Protocol

BSSMAP timers T1 T13 T17 T18 T19 T20 N/A T3121 T4 T7 T10 T3107 T3103 T8 T3122 BSSMAP timers BSSMAP timers BSSMAP timers BSSMAP timers BSSMAP timers BSSMAP timers BSSMAP timers BSSMAP timers

BSSMAP timers

T3101 T3109 T3111 T3168 T3192


BSSMAP

TLC N/A TLW N/A TLH TLWH


. BSSMAP

BSSMAP BSSMAP

Flexi BSC Signification Timer T1 specifies the time limit in which the remote end of the connection must acknowledge the receipt of the frame. If this timer expires, the frame is transmitted again. RESET guard period Overload procedure (The timer T17 supervises the overload procedure in MSC overload.) Overload procedure(The timer T18 supervises the overload procedure. For a detailed description see 3GPP TS 08.08, MSC-BSS Interface, Layer 3 Specification.) BSS Obj Range

BSC BSC BSC BSC BSC BSC N/A

10s 5..30s 1..120s 3..180s 10s 10s N/A 8..15s 10..120s 5..30s 4..14s 3.5..28s 3.5..28s 8..15s 2255s 1..5s 8..15s

GSM to WCDMA RAN handover procedure supervision in the source BSC Supervision of sending the RESET to the MSC Frequency of the HANDOVER_REQUIRED message Supervision of the assignment procedure Supervision of the assignment procedure Supervision of the internal handover procedure Handover procedure supervision in the source BSC Delay of sending another channel request message Supervision of the immediate assignment procedure Supervision of the channel release procedure Delay of channel deactivation Wait for Packet Uplink Assignment message

BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BTS

0.5s
0..7

Wait for release of the TBF after reception of the final block With this parameter you define the maximum queueing time for call attempts (incoming or outgoing) in the BTS in seconds. Value 0 deactivates call attempt queueing. With this parameter you define the maximum queuing time in seconds for WPS call setup attempts. With this parameter you define the maximum queueing time for handover attempts (both urgent and non-urgent) in the BTS in seconds. With this parameter you define the maximum queuing time in seconds for WPS handover attempts

0..2 0...15s

BTS

0...30s

BTS BTS

0...10s 0...30s

Siemens BSC BSS Default BR Obj BR Parameter Value 10s 15s 4s 12s 10s 10s N/A 12s 60s 20s 8s 6s 6s 12s 6s BR Value Mapped Value To BR's 10s what is applied now in siemens

BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BSC BTS BTS BTS BTS BTS BSC BSC

BSCT1 BSCT13 BSCT17 BSCT18 BSCT19 BSCT20 BSCT3 BSCT3121 BSCT4 BSCT7 BSCT10 BSCT8 T3122

HLFSEC-12 HLFSEC-50 HLFSEC-20 HLFSEC-60 HLFSEC-12 HLFSEC-12 HLFSEC-50 HLFSEC-10 HLFSEC-60 HLFSEC-12 HLFSEC-10 HLFSEC-10 5

10s 10s N/A

5s

3s 4s 0.5s 2
0 10s

T3101 T3109 T3111 T3168


T3192 BSCT11PUB BSCT14PUB BSCT11WPS BSCT14WPS

HLFSEC-6 HLFSEC-8 HLFSEC-3 2 0 HLFSEC-12 HLFSEC-16 HLFSEC-16 HLFSEC-16

3s 4s 0.5s 2
0 6

T3122=5 HLFSEC-6 HLFSEC-8 T3168=2


T3192=0 HLFSEC-20

28 s

BSC BSC

5s 5s

BSC BSC

BSCTQHOPUB HLFSEC-6 BSCTQHOWPS HLFSEC-20

3 0

HLFSEC-6

Comment

Fixed value Since the used value in BR is the default value then the default value of BSS is recommended Since the used value in BR is the default value then the default value of BSS is recommended Since the used value in BR is the default value then the default value of BSS is recommended Fixed value Fixed value N/A Since the used value in BR is the default value then the default value of BSS is recommended Since the used value in BR is the default value then the default value of BSS is recommended BSS default value is recommended BSS default value is recommended for the four timers since they are dependant on each others

Mapped Mapped Mapped Fixed value Mapped

Mapped

Mapped

WPS is not used

Mapped WPS is not used