Professional Documents
Culture Documents
Qty
Rate
Unit
1.1 Wiring for light point / fan point / exhaust fan point /call bell point with 1.5 sq. mm. FR PVC insulated copper conductor cable in surface / recessed STEEL conduit with piano type switch, phenolic laminated sheet, suitable size MS box & earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as reqd Group A Group B Group C 1.2 Wiring for twin control light point with 1.5 sq. mm. FR PVC insulated copper conductor cable in surface / recessed Steel conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box & earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as reqd 1.3 Wiring for light point / fan point / exhaust fan point /call bell point with 1.5 sq. mm. FR PVC insulated copper conductor cable in surface / recessed STEEL conduit with modular switch, modular plate, suitable GI box & earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as reqd. Group A Group B Group C 1.4 Wiring for twin control light point with 1.5 sq. mm. FR PVC insulated copper conductor cable in surface / recessed Steel conduit, 2 way modular switch, modular plate, suitable GI box & earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as reqd 617.00 1.5 Wiring for light / power plug wiring with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed STEEL conduit alongwith 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for earthing as reqd. 136.00 Metre 1.6 Wiring for light / power plug wiring with 4 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed STEEL conduit alongwith 2 Nos. 4 sq. mm FR PVC insulated copper conductor single core cable for earthing as reqd. 191.00 Metre Point 392.00 466.00 589.00 Point Point Point 361.00 436.00 559.00 Point Point Point
560.00
Point
1.7 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed STEEL conduit as reqd. i 2 x 1.5 sq.mm.+ 1 x 1.5 sq.mm. FR earth ii wire 2 x 2.5 sq.mm.+ 1 x 2.5 sq.mm. FR earth iii wire 2 x 4 sq.mm.+ 1 x 4 sq.mm. FR earth wire iv 2 x 6 sq.mm.+ 1 x 6 sq.mm. FR earth wire v 2 x 10 sq.mm.+ 1 x 10 sq.mm. FR earth wire vi 2 x 16 sq.mm.+ 1 x 16 sq.mm. FR earth wire vii 2 x 25 sq.mm.+ 1 x 25 sq.mm. FR earth wire viii 4 x 2.5 sq.mm.+ 2 x 2.5 sq.mm. FR earth ix wire 4 x 4 sq.mm.+ 2 x 4 sq.mm. FR earth wire x 4 x 6 sq.mm.+ 2 x 6 sq.mm. FR earth wire xi 4 x 10 sq.mm.+ 2 x 10 sq.mm. FR earth wire xii 4 x 16 sq.mm.+ 2 x 16 sq.mm. FR earth wire xiii 4 x 25 sq.mm.+ 2 x 25 sq.mm. FR earth wire
160.00 Metre 190.00 Metre 258.00 Metre 367.00 Metre 590.00 Metre 717.00 Metre
398.00
Point
1.12 Wiring for light / power plug wiring with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 4 sq. mm FR PVC insulated copper conductor single core cable for earthing as reqd. 97.00 Metre 1.13 Wiring for light / power plug wiring with 4 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 2 Nos. 4 sq. mm FR PVC insulated copper conductor single core cable for earthing as reqd. 149.00 Metre 1.14 Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as reqd. i 2 x 1.5 sq.mm.+ 1 x 1.5 sq.mm. FR earth ii wire 2 x 2.5 sq.mm.+ 1 x 2.5 sq.mm. FR earth iii wire 2 x 4 sq.mm.+ 1 x 4 sq.mm. FR earth wire iv 2 x 6 sq.mm.+ 1 x 6 sq.mm. FR earth wire 127.00 Metre v 2 x 10 sq.mm.+ 1 x 10 sq.mm. FR earth wire 171.00 Metre vi 2 x 16 sq.mm.+ 1 x 16 sq.mm. FR earth wire 269.00 Metre vii 2 x 25 sq.mm.+ 1 x 25 sq.mm. FR earth wire viii 4 x 2.5 sq.mm.+ 2 x 2.5 sq.mm. FR earth wire ix 4 x 4 sq.mm.+ 2 x 4 sq.mm. FR earth wire x 4 x 6 sq.mm.+ 2 x 6 sq.mm. FR earth wire 207.00 Metre xi 4 x 10 sq.mm.+ 2 x 10 sq.mm. FR earth wire 294.00 Metre xii 4 x 16 sq.mm.+ 2 x 16 sq.mm. FR earth wire 487.00 Metre xiii 4 x 25 sq.mm.+ 2 x 25 sq.mm. FR earth wire 638.00 Metre 1.15 Rewiring for light point / fan point / exhaust fan point /call bell point with 1.5 sq. mm. FR PVC insulated copper conductor cable and 1.5 sq. mm FR PVC insulated copper conductor single core cable as earth wire in existing surface / recessed STEEL / PVC conduit including dismantling as reqd Group A Group B Group C 1.16 Rewiring for twin control light point with 1.5 sq. mm. FR PVC insulated copper conductor cable and 1.5 sq. mm FR PVC insulated copper conductor single core cable as earth wire in existing surface / recessed STEEL / PVC conduit including dismantling as reqd 200.00 Point 125.00 144.00 200.00 Point Point Point 355.00 Metre 118.00 Metre 148.00 Metre 71.00 Metre 81.00 Metre 97.00 Metre
1.17 Supplying and drawing following sizes of FR PVC insulated copper conductor single core cable in the existing surface recessed STEEL / PVC conduit / PVC casing & as mm reqd. 1 x 1.5 sq. i capping ii iii iv v vi vii viii ix x xi xii xiii xiv xv xvi xvii xvii xix xx xxi xxii xxiii xxiv xxv xxvi xxvii xxviii xxix xxx xxxi xxxii xxxiii xxxiv xxxv xxxvi xxxvii 2 x 1.5 sq. mm 3 x 1.5 sq. mm 4 x 1.5 sq. mm 5 x 1.5 sq. mm 6 x 1.5 sq. mm 7 x 1.5 sq. mm 8 x 1.5 sq. mm 9 x 1.5 sq. mm 10 x 1.5 sq. mm 2 x 2.5 sq. mm 3 x 2.5 sq. mm 4 x 2.5 sq. mm 5 x 2.5 sq. mm 6 x 2.5 sq. mm 7 x 2.5 sq. mm 8 x 2.5 sq. mm 9 x 2.5 sq. mm 10 x 2.5 sq. mm 2 x 4 sq. mm 3 x 4 sq. mm 4 x 4 sq. mm 5 x 4 sq. mm 6 x 4 sq. mm 7 x 4 sq. mm 8 x 4 sq. mm 9 x 4 sq. mm 10 x 4 sq. mm 2 x 6 sq. mm 3 x 6 sq. mm 4 x 6 sq. mm 5 x 6 sq. mm 6 x 6 sq. mm 7 x 6 sq. mm 8 x 6 sq. mm 9 x 6 sq. mm 10 x 6 sq. mm
19.00 25.00 32.00 38.00 45.00 52.00 58.00 65.00 71.00 78.00 32.00 43.00 53.00 63.00 73.00 83.00 93.00 104.00 114.00 43.00 58.00 73.00 88.00 103.00 119.00 134.00 149.00 164.00 59.00 83.00 106.00 130.00 154.00 178.00 202.00 225.00 249.00
Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr. Mtr.
1.18 Supplying and drawing following pair, 0.5 sq. mm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as reqd. i1 Pair ii 2 Pair iii 4 Pair 1.19 Supplying and drawing co-axial TV cable RG6 grade, 0.7 mm solid copper conductor, PE insulated, shielded with fine tinned copper braid & protected with PVC sheath in the existing surface / recessed steel / PVC conduit as reqd. 1.20 Supplying and fixing following sizes of STEEL conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm ii 25 mm
23.00 Metre
iii 32 mm iv 40 mm v 50 mm 1.21 Supplying and fixing following sizes of PVC conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. i 20 mm ii 25 mm iii 32 mm iv 40 mm v 50 mm 1.22 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. i 75mm x 75mm x 60 mm deep. ii 100mm x 100mm x 60 mm deep. iii 150mm x 75mm x 60 mm deep. iv 150mm x 150mm x 60 mm deep. v 180mm x 100mm x 60 mm deep. vi 200mm x 125mm x 60 mm deep. vii 200mm x 150mm x 60 mm deep. viii 200mm x 150mm x 75 mm deep. xix 200mm x 250mm x 60 mm deep. x 200mm x 250mm x 75 mm deep. xi 200mm x 150mm x100 mm deep. xii 200mm x 250mm x100 mm deep. xiii 200mm x 300mm x 60 mm deep. xxiv 200mm x 300mm x 100 mm deep. xv 250mm x 300mm x 60 mm deep. xvi 250mm x 300mm x 100 mm deep.
55.00 64.00 67.00 87.00 80.00 97.00 105.00 107.00 137.00 143.00 128.00 153.00 154.00 171.00 176.00 191.00
Each Each Each Each Each Each Each Each Each Each Each Each Each Each Each Each
10
Supplying and fixing of suitable size GI box with modular platel and cover in front on surface or in recess, i/c providing and fixing fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch,connections,painting etc. as reqd.(for light plugs to be used in non residential buildings). Supplying and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, i/c providing and fixing fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch,connection,painting etc. as reqd.
171.00
each
11
230.00 12 Supplying &fixing 20 amps, 240 volts SPN industrials type socket outlet with 2 pole and earth , metal enclosed plug top along with 20amps 'C' series SP, MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections,testing and commissioning etc as reqd.( AC and water cooler)
Each
628.00
Each
13
Supplying of Metalic Wall Mounting type Decorative fitting along with 2 X 18W CFL lamps with perforated white cover for soft ambient glare free illumination complete as required. (Make :Wipro/Philips/Bajaj,similar to Crompton Lattice CWL218) 1565.00 Each
14
Suppying of 1 x 36 W CFL fluorescent fittings having steeel profile with vacuum matalisedcross louvers,decorative end covers and provided with ultra slim VPIT ballast along with all accessories and 1No. CFL tubes etc directly on ceiling / wall including connection with 1.5sq mm PVC insulated copper conductor single core cable etc as reqd.(Make Wipro/Philips/Bajaj, similar to Crompton Platina CSBE 136MCVB1 x 36W CFL) Supplying of 1 x 36W Mirror Optic Indoor decorative Surface mounted luminaire for T81 amp with electronic ballast and all other accessories and 1 No. 36/40 W Triphospher fluorescent tubes etc. directly on ceiling / wall including connection with 1.5 sq mm PVC insulated copper conductor single core cable etc as reqd.( make : Wipro/Bajaj/Crompton,similar to Philips cat No.TCS-605/136HF) Supplying of 2 x 11 W CFL fittings ceiling luminaire with mirror optic housing aesthitically designed using 3D profile high grade engineering plastic along with all accessories and 2 Nos. CFL tubes etc. directly on ceiling / wall including connection with 1.5 sq mm PVC insulated copper conductor single core cable etc. as reqd. (make : Wipro/Bajaj/Crompton,similar to Philips cat No.FCS-518/211)
1123.00
Each
15
2378.00
Each
16
1161.00 17 Supplying of 1 x 11 watt wall mounted decorative CFL tube fittings,complete with ballast,lamp holders, prismatic or plain glare free diffuser, and capacitor, duly wired for use on 240 volts single phase 50 Hz AC supply, powder coated housing with ABS end capswith all accessories with built in starter & 1 No 11 watt CFL lamps etc as reqd. (Make : Wipro/Bajaj/Crompton,similar to Philips cat No.FCS-518/211) 600.00 18 Supplying and fixing bulk head light fitting of approved make made of aluminium casting with glass shade and wire guard with 1 No. 60 W GLS lamp including making of connections, earthing etc as reqd. 325.00 19 Suppling of metalic wall mountings type decorative fitting along with 2 x 18 watt CFL lamps with perforated white cover for soft ambient glare free illumination complete as reqd. (Make :Wipro/Philips/Bajaj,similar to Crompton Lattice CWL218) 1558.00
Each
Each
Each
Each
20
Supplying of electric ceiling fans of the following sizes without regulator, capacitor type with double ball bearing complete with capacitor 300mm down rod, canopies, shackles three number blades made of aluminium alloy, suitable for single phase, AC 230V 50 Hz supply & as per IS:374/1979 and having ISI marked as reqd. (a) 1200 mm sweep (b) 1400 mm sweep 1050.00 1250.00 Each Each
21
Supplying of the following sized of propeller type exhaust fan suitable for 900 RPM for single phase AC 230 volts 50 Hz capacitorrun as per IS: 2313/67 and having ISI marked complete with mounting ring with four fixing holes with louver shutter but without regulator etc as reqd.
(a) 200 mm sweep 22 Supplying Steppped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd.
1050.00
Each
193.00
Each
23
Installation testing and commissioning of prewired fluo/CFL fittings of all types complete with all accessories and tubes etc. directly on ceiling/wall I/c connection with 1.5 sq.mm. PVC insulated copper conductor single core cable and earthing etc. as required. Installation testing & commissioning of ceiling fan, I/c wiring the down rod of standard length (upto 30 cm.) with 1.5 sq.mm. PVC insulated, copper conductor, single core cable i/c providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
42.00
Each
24
67.00 25 Installation of exhaust fan upto 450 mm sweep in the existing opening, I/c making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Each
215.00 26 Extra for fixing the louvers/ Shutters complete with frame for a exhaust fan of all sizes. Numbering of ceiling fan/ fan/fluorescent fittings as reqd. exhaust 10.00
Each
63.00
Each
27
Each
28
Supplying & fixing call bell/buzzer and piano type bell push suitable for A.C./D.C. single phase, 230 volts complete as reqd. Supplying,installing on wall, testing and commisssioning of following capacity rising mains with metal clad enclosure, wall straps, fully PVC insulated TPN aluminium busbars in convenient sections and suitable for 400/650volts, 3 phase, 4wire , 50Hz A.C. supply with extension joints, fire proof barriers, expansion joints,thrust pads including joiting and earthing with 2 runs of galvanised iron strips tec. as reqd. (i) 400 amps TPN
37.00
Each
29
4798.00 Meters
30
Supplying, installing, testing and commissioning of TPN tap off box of following capacity on existing rising mains and complete with HRC fuse links, interconnections,earthing etc. as reqd. (i) 63 amps TPN (ii) 100 amps TPN
6487.00 9183.00
Each Each
31
Supplying, installation, testing and commissioning of surface/ recess mounting, vertical type 415 volts, prewired TPN MCB distribution board of sheet steel, dust protected, duly phosphatized and powder painted, inclusive of 200amps tinned copper busbar, common neutral link, earth bar, din bar for mounting MCB's detachable gland knock out plate an with built in loose wire box and superior make terminal connectors for all incoming and outgoing circuits duly prewired with adequate size of PVC insulated copper consductor upto the terminal connector/ neutral link and ready for installation of folowing ways (but without MCB's and incomer) as reqd. (a) 4 way (Double door) 9565.00 Each
32
Supplying and fixing following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts on surface / recess , complete with tinned copper busbar, neutral busbar, earth bar, din bar detachable gland plate, interconnections,phosphatized and powder painted including earthing ect. as reqd.( But without MCB/RCCB Isolator.)
2103.00
Each
33
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts on surface / recess , complete with tinned copper busbar, neutral busbar, earth bar, din bar detachable gland plate, interconnections,phosphatized and powder painted including earthing ect. as reqd.( But without MCB/RCCB Isolator.) (a) 12 way (Double door) (b) 8 way (Double door) 1021.00 790.00 Each Each
34
Supplying and fixing 5 amps to 32 amps rating, 240 volts. 'B' series miniature circuit breaker suitable for lighting and other loads of following ploes in the existing MCB DB complete with connections, testing and commissioning etc as reqd.
a) Single Pole 35 Supplying and fixing 5 amps to 32 amps rating, 240 volts. 'C' series miniature circuit breaker suitable for lighting and other loads of following ploes in the existing MCB DB complete with connections, testing and commissioning etc as reqd. a) Single Pole b) Single Pole & Neutral 36 Supplying and fixing following rating double pole,( single phase & neutral) 240 volts, residual current circuit breaker (RCCB) having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as reqd a) 63 Amp Supplying and fixing following rating Four pole,( three phase & neutral) 415 volts, residual current circuit breaker (RCCB) having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as reqd a) 63 Amp Supplying and fixing single pole blankinng plate in the existing MCB DB Complete as reqd.
91.00
Each
93.00 208.00
Each Each
1364.00
Each
37
1540.00
Each
38
2.00
Each
39
Earthing with copper earth plate 600mm x 600mm x 3mm thick I/c accessories and providing masnary enclosure with cover plate having locking arrangement watering pipe etc. (but without charcoal or coke and salt) complete as reqd.
3598.00
Set
40
Extra for using salt and charcoal for G.I. / or copper plate earth electrode as required. 670.00 Set
41
Providing and fixing 25mm x 5mm copper strip in 40mm dia GI pipe from earth electrode as required. Pdg. & fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required. Providing and Fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit /submain wiring / cable as reqd.
547.00
Mtr
42
393.00
Mtr
43
40.00 44 Supplying and fixing of following sizes of steel conduit along with accessories in surface recess i/c painting in case of surface conduit or cutting the wall and making good the same in case of recessed conduit as reqd. (a) 25 mm dia Supplying and fixing metal box of following sizes (nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c painting etc as reqd.
Mtr
115.00
Mtr
45
(a) 250mm x 300 mm x 100mm deep 46 Supplying installing, Testing & Commissioning of ESELC air Termination System including FRP mast 2 met its give area radius 109 met in air (Model S-6. 60) Supplying & laying of single core 70 sq mm pure electroytic PVC insulated flexible copper conductor cable etc as reqd.
198.00
Each
290000.00
Each
47
550.00 Metre
TOTAL SUB HEAD - V Rs. SUB- HEAD - VI (SUPPLY & MATERIALS) Supply of following materials cofirming to relevant specifications etc as reqd. 2 x 40 W Box type flou. Fitting. 9 1 x 40 W Box type flou. Fitting. 1200 mm AC ceiling fans. 2 x 11 W CFL fitting mirror optic. 2 x 40 W mirror optic - type fluo. 40 W fluo lamp 68 52 78 6 98
1 2 3 4 5 6
366.00 Each 220.00 Each 900.00 Each 380.00 Each 906.00 Each 42.00 Each
7 8
11 W CFL lamp Fancy wall bracket suitable for 100 W GLS lamps as per DGS & D SK - 14.
156
102.00 Each
30
202.00 Each
Mirror light fittings on wash basin suitable for 100 W GLS lamps as per DGS & D SK -9 10 210mm dia ceiling flush fittings suitable for 100 W GLS as per DGS & D SK -7 11 Bulk head fittings suitable for 100 W GLS lamps as per DGS & D SK - 11 12 Bed side fittings suitable for 100 W GLS lamps as per DGS & D Sk - 8 13 Storage type electic water heater of 25 ltr capacity with 1500 W heater horizontal type 30 N/cm2
20
185.00 Each
72
189.00 Each
18
152.00 Each
18
130.00 Each
18
Name of Work: Construction of Transit accommodation for IMD, Pashan, Pune. SH: Pdg. IEI & fans I/c power wiring, TV & Telephone conduit etc.
ABSTRACT OF COST
1 2 3 4 5 6 #REF! 0 0 SUB- HEAD - VI (SUPPLY & MATERIALS) TOTAL Rs. Add Contingencies @ 5 % GRAND TOTAL Say Rs. #REF! 0
SCHEDULE OF WORK
Name of Work: Construction of Transit Accommodation for IMD, Pashan, Pune. SH: Pdg. IEI & fans I/c power wiring, TV & Telephone conduit etc.
No. 1 Description of item SUB- HEAD - I (WIRING ) Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm. PVC FRLS insulated copper conductor cable along with 1 No. 4 sq. mm PVC insulated copper GREEN wire for loop earthing in surface / recess PVC conduit with 1 or 2 modular GI sheet metal box having single module white finish plate & 6A 1 way modular switch as required. Supplying and fixing following sizes of PVC conduit along with the accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm dia b) 25 mm dia Telephone/TV) c) 32 mm dia 3 Supplying and drawing following sizes of PVC FRLS insulated copper conductor single core cable in the existing surface recessed PVC/ steel conduit / PVC casing and capping as required. (a) 2x1.5 sqmm PVC FRLS + 1x4 sqmm PVC (b) 4x1.5 sqmm PVC FRLS + 2x4 sqmm PVC (200 + 480 for 1680 Mtrs. 750 Mtrs. 23.00 33.00 Mtr. Mtr. 450 Mtrs. 17.00 Mtr. Qty Rate Unit
459 Pts.
510.00 Point
450 Mtrs.
52.00
Mtr.
200 Mtrs.
90.00
Mtr.
(c) 2x4 sqmm PVC FRLS + 1x4 sqmm 1000 Mtrs. PVC (d) 4x4 sqmm PVC FRLS + 2x4 sqmm PVC (e) 2x6 sqmm PVC FRLS + 1x6 sqmm PVC 250 Mtrs. 500 Mtrs.
No. 1
Description of item SUB- HEAD - II (FANS & FITTINGS) Supplying and fixing of 3 module modular ROMA /MK make recess type MS box with white modular plate & 6A ROMA/MK modular unit socket - 1 No. complete with connection earthing, testing etc. as reqd.
Qty
Rate
Unit
147 Nos. 2 Supplying and fixing of 3 module modular ROMA /MK make recess type MS box with white modular plate & 15/16 A ROMA/ MK modular switch 1 no. & 15/16 A ROMA/MK modular socket - 1no. complete with connections, earthing testing etc as reqd. Supplying and fixing of 1 module modular ROMA /MK make recess type MS box with white modular plate & 1 No. ROMA/ MK telephone jack etc as reqd. Supplying and fixing of 1 module modular ROMA /MK make recess type MS box with white modular plate & 1 No. ROMA/ MK single outlet TV socket etc as reqd. Supplying and fixing brass batten/angle holder including connections etc. as required. Supplying & fixing Ding dong bell & ROMA/MK bell push, suitable for AC/DC single phase, 230 volts complete as reqd. Supplying & fixing of ROMA/MK make fan regulator on the existing board complete with connection testing etc as req. Numbering of ceiling fans/exhaust fans/ fluorescent fittings etc as reqd. Supply Installation testing & commissioning of 1200 mm sweep ceiling fan and regulator I/c wiring the down rod of standard length (upto 30 cm.) with 1.5 sq.mm. PVC insulates copper conductor, single core cable etc. as required.
273.00 Each
50 Nos.
382.00 Each
19 Nos.
178.00 Each
18 Nos.
175.00 Each
32 Nos.
30.00 Each
19 Nos.
192.00 Each
52 Nos.
440.00 Each
232 Nos.
4.00 Each
52 Nos.
1250.00 Each
No. Description of item 10 Supply Installation testing and commissioning of following prewired fluo/CFL fittings of all types complete with all accessories and tubes etc. directly on ceiling/wall I/c connection with 1.5 sq.mm. PVC insulated copper conductor single core cable etc. as required. (a) (b) 11 Supply & Erection of follwing fitting of all sizes & shapes containing upto 2 GLS lamps per fitting complete with all accessories I/c connection etc as reqd. (a) (b) 12 Supply & Installation of 300 mm sweep exhaust fan in the existing opening, I/c making the hole to suit the size of the above fan, making good the damage, alongwith louvers/shutters complete with frame connections, testing, commissioning etc. as required. 13 Supply & Installation of 25 ltr capacity with 1500W heater horizontal type 30 N/cm2 storage type electric water heater on wall with fasteners I/c making connection to water pipe in intet as wall as outlet side connection, testing & commissioning etc as reqd.
Qty
Rate
Unit
Nos. Nos.
Each Each
Nos. Nos.
Each Each
19 Nos.
1550.00 Each
18 Nos.
3500.00 Each
TOTAL SUB HEAD - II Rs. 1 SUB- HEAD - III ( MAIN BOARD & SDB's ) Supplying & fixing of 12 way single pole & neutral sheet steel surface/ recessed type MCB distribution board having double metal door, 240 volts on surface/ recessed complete with tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections i/c painting earthing etc. as reqd. 19 Nos. 1189.00 Each
No.
Description of item
Qty
Rate
Unit
S/I/T/C of floor wall mounted type compartmentalized cubical meter panel board fabricated put of 1.6 mm thick M.S. sheet with suitable size stand made of 50mm x 50mm x 6mm in approved manner etc. Suitable for 415/433V 3 phase, 50 Hz 4 wire AC supply, detachable gland plate at bottom, hinged door, front cable holding bracket, earth bars providing and fixing of following switch gears connections and inter connection with PVC insulated multistrand copper flexible conductors, duly sleeved, tag, lugs, etc. Painted with approved shade of epoxy powder coating as reqd. The panel should be as per CPWD specification for electrical sub (A) station Incoming work 1982 (Part IV) and IEI Rules
I) 200 amps FP MCCB 25 KA - 1No. II) 200 amps 4 strips aluminium bud bar - 1 No. (B) Outgoing I) 40 amps SPN MCB 'B' series - 20 Nos. II) Single phase energy meter (Electronic type) range 5 amp to 20 amp (with test certificate) - 19 Nos. NOTE: - (Meter box should be kept lockable arrangement and suitable size glass should be provided in the front door)
1 No.
83561.00 Each
Supplying & fixing 40 A double pole (SP&N) 240 volts, RCCB having a sensitively current upto 300 milliamperes in the existing MCBDB complete with connecting testing & commissioning etc. Supplying & fixing sheet steel enclosure on surface or in recess suitable for 20 A SPN MCB etc as reqd.
19 Nos.
1164.00 Each
18 Nos. 5 Supply & fixing of following rating/ series /poles, 240V MCB in the existing MCB DB/ metal enclosure complete with connections testing and commissioning etc. reqd. (a) 6as amps 'B' series SPMCB (b) 16 amps 'C' series SPMCB (c) 20 amps 'C' series SPMCB (d) 20 amps 'C' series SPNMCB
125.00 Each
TOTAL SUB HEAD - III Rs. No. 1 Description of item SUB- HEAD - IV ( EARTHING) Earthing with G.I. Earth pipe 4.5 mtr. long x 40 mm dia I/c accessories and providing masonary enclosure with cover plate having locking arrangement watering pipe etc. (but without charcoal or coke and salt) complete as reqd. Qty Rate Unit
2 Sets
751.00
Set
2 3
Extra for using salt and charcoal for pipe earth electrode as required. Supplying and fixing 25mm x 5mm GI strip in 40mm dia GI pipe from earth electrode as required. Pdg. & fixing 25mm x 5mm GI strip on surface or in recess for connections etc. as required.
2 Sets
182.00
Set
12 Mtrs.
142.00
Mtr
10 Mtrs.
52.00
Mtr
ABSTRACT OF COST
1 2 3 4 SUB- HEAD - I (WIRING ) SUB- HEAD - II (FANS & FITTINGS) SUB- HEAD - III ( MAIN BOARD & SDB's ) SUB- HEAD - IV ( EARTHING) TOTAL Rs. Add Contingencies @ 5 % Rs. GRAND TOTAL Say Rs.
Amount
0.00
0.00
0.00
0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00
0.00
0.00
0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00
0.00 0.00
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
#REF! 0.00
0.00
0.00
0.00 0.00
0.00
0.00 0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
15912.00
6060.00
3700.00
13608.00
2736.00
2340.00
57546.00 206148.00
0.00 #REF! #REF! 0.00 0.00 206148.00 #REF! #REF! #REF! #REF!
234090.00
23400.00
18000.00
Amount
40131.00
19100.00
3382.00
3150.00
960.00
3648.00
22880.00
928.00
65000.00
Amount
0.00 0.00
0.00 0.00
29450.00
63000.00 251629.00
22591.00
Amount
83561.00
22116.00
2250.00
1502.00
364.00
1704.00
520.00 4090.00
No.
Description of item
Qty
Rate
Unit
1.23 Supplying & fixing following piano type switch / socket on the existing switch box / cover including connections etc. as reqd. i 5 / 6 amps switch ii 2 way 5 / 6 amps switch iii 15 / 16 amps switch iv 3 pin 5 / 6 amps socket out let v 6 pin 15 / 16 amps socket out let vi Telephone socket out let vii TV antenna socket out let 1.24 Supplying & fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as reqd. i ii iii iv v vi vii 5 / 6 amps switch 2 way 5 / 6 amps switch 15 / 16 amps switch 3 pin 5 / 6 amps socket out let 6 pin 15 / 16 amps socket out let Telephone socket out let TV antenna socket out let
1.25 Supplying & fixing Stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd. 247.00 Each 1.26 Supplying & fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as reqd. 1.27 Supplyingy & fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc. as reqd. i 1 or 2 module (75mm x 75 mm) ii 4 module (125mm x 75 mm) iii 6 module (200mm x 75 mm) iv 8 module (125mm x 125 mm) v 12 module (200mm x 150 mm) 1.28 Supplyingy & fixing following modular base & cover plate on the existing modular metal boxes etc. as reqd. i ii iii iv v 1 or 2 module 4 module 6 module 8 module 12 module 51.00 71.00 98.00 113.00 145.00 Each Each Each Each Each
20.00 Each
mm deep (Nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front I/c providing and fixing 3 pin 5/6 amp socket outlet and 5/6 amp tumbler/piano type switch connection, painting etc. as reqd. (for light plugs to be used in non resdl. bldg.) 1.30 Supplying & fixing metal box of 180mmx 100mmx 60mm deep (nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in the front I/c providing & fixing 6 pin 5 / 6 & 15/16 A socket outlet and 15/16 amp Piano type switch connections, painting etc as reqd.
102.00 Each
161.00 Each
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, i/c. providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connections, painting etc. as reqd.(for light plugs to be used in non residential buildings). 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, i/c. providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connections, painting etc. as reqd. 1.33 Supplying & fixing 3 pin, ceiling rose on the existing junction box/ wooden block including connection etc. as reqd. 1.34 Supplying and fixing brass batten / angle holder including connection etc. as reqd. 1.35 Erection of wall bracket /ceiling fitting of all sizes & shapes containing upto two GLS lamps per fittings complete with all accessories I/c connections etc. as required. 1.36 Supplying and fixing stiff pendent with 300mm long, 20mm dia X 1.6mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FR PVC insulated, copper conductor single core cable and painting etc. as required. 1.37 Supplying and fixing stiff pendent with 600mm long, 20mm dia X 1.6mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FR PVC insulated, copper conductor single core cable and painting etc. as required. 1.38 Supplying and fixing call bell / buzzer, suitable for DC/AC single phase, 230 volts, complete etc as reqd.
160.00 Each
214.00 Each
19.00 Each
33.00 Each
19.00 Each
75.00 Each
93.00 Each
26.00 Each 1.39 Providing and fixing plain 16/0.20mm twin twisted, flexible, FR PVC insulated, copper cable, in polythene sleeve, or conduit of suitable size on the floor/wall, or side of the table/door etc as reqd. 1.40 Providing and fixing plain 16/0.20mm FR PVC insulated, PVC sheathed, flat flexible copper cable on the floor/wall, or side of the table/door etc as reqd. 1.41 Installation testing & commissioning of prewired flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on celling / wall, including connections with 1.5 sq. mm FR PVC insulated, copper conductor single core cable and earthing etc. as required.
14.00 Metre
10.00 Metre
43.00 Each
1.42 Installation testing & commissioning of prewired flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc., including supplying & fixing ball and socket arrangement, 2 Nos. down rod of 20mm dia x 1.6mm thick steel conduit upto 30cm length, painting and wiring the down rods and connections with 1.5 sq. mm FR PVC insulated, copper conductor single core cable and earthing etc. as required. 1.43 Providing and fixing extra down rod of 20mm dia, 2 x 10 cm length wiring with 2 x 1.5 sq. mm FR PVC insulated, copper conductor, single core cable including painting etc. as reqd. (Note : More than 5 cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored) 1.44 Installation testing & commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq. mm FR PVC insulated, copper conductor single core cable etc. as required.
126.00 Each
17.00 Each
45.00 Each 1.45 Installation testing & commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 sq. mm FR PVC insulated, copper conductor single core cable, including providing & fixing phenolic laminated sheet cover on the fan box etc. as required. 1.46 Installation testing & commissioning of resistance type ceiling fan regulator in existing switch box, including connection with 1.5 sq. mm FR PVC insulated, copper conductor single core cable, earthing the regulator etc. as required. 1.47 Extra for cutting & threading of GI pipe, heavy guage down rod, for ceiling fan etc. as reqd. 1.48 Supplying & fixing extra down rod of 10cm length GI pipe, 15mm dia, heavy guage including painting etc. as reqd. (Note : More than 5 cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored) 13.00 Each 1.49 Supplying & fixing extra down rod of 20cm length GI pipe, 15mm dia, heavy guage including painting etc. as reqd. (Note : More than 5 cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored) 13.00 Each 1.50 Carriage of ceiling fan and regulator / exhaust fan/ flourescent fittings as reqd. 1.51 Numbering of ceiling fan/ exhaust fan/ flourescent fittings as reqd. 1.52 Installation of exhaust fan upto 450mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as reqd.
68.00 Each
27.00 Each
10.00 Each
8.00 Each
10.00 Each
223.00 Each
1.53 Installation of exhaust fan upto 510mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as reqd. 1.54 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1.55 Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade including cleaning of surface with detergent etc. as reqd.
325.00 Each
65.00 Each
44.00 Each
Amount
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
No.
Description of item
Qty
Rate
Unit
Amount
3293.00 4882.00 6855.00 7608.00 4354.00 6552.00 10481.00 12498.00 7672.00 11000.00 15429.00 21356.00 21895.00 32867.00 43751.00
Each Each Each Each Each Each Each Each Each Each Each Each Each Each Each
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
i ii iii iv v
adoptoer box of following capacity on existing rising mains & complete with stands, cable end boxd, brass compression gland, interconnections, earthing etc. as reqd. 200 amps TPN 300 amps TPN 400 amps TPN 600 amps TPN 800 amps TPN
trucking arrangement in convinient sections complete with aluminium busbars for use on 3 phase, 4 wire, 415 volts, 50 Hz, AC supply for following capacity including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 run of galvanised iron strips etc. as reqd. i ii iii iv v 800 amps TPN 1000 amps TPN 1250 amps TPN 1400 amps TPN 1600 amps TPN 7790.00 9221.00 9668.00 12060.00 13518.00 Metre Metre Metre Metre Metre 0.00 0.00 0.00 0.00 0.00
2.16 Supplying, installing including suspension, testing and commissioining of triple pole & neutral over head aluminium busbar in sheet steel enclosure in convinient sections with top and bottom covers suitavle for use on 3 phase, 4 wire, 415 volts, 50 Hz, AC supply and of following rating complete with jointing of sections, electrical connections/ interconnections, earthing with 2 run of galvanised iron strips etc. as reqd. i 200 amps ii 400 amps 2.17 Supplying, installing, testing and commissioining of TPN plug-in box of following capacity on existing over head busbar system complete with HRC fuse links, electrical interconnections, earthing etc. as reqd. i 32 amps ii 63 amps iii 100 amps
0.00 0.00
1613.00 2361.00 3592.00 3932.00 4209.00 5501.00 6524.00 8564.00 11631.00 11631.00 12802.00 12802.00 15726.00
Each Each Each Each Each Each Each Each Each Each Each Each Each
0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
2.32 Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board consumer unit, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, hinged front acrylic cover for the knobs, detachable gland plate, interconnectionms, phosphatized and powder painted including earthing as reqd. (But without MCB/RCCB/Isolator) i ii iii iv 2 + 4 way 2 + 8 way 2 + 12 way 2 + 16 way 559.00 654.00 753.00 850.00 Each Each Each Each 0.00 0.00 0.00 0.00
2.33 Supplying and fixing following way three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnectionms, phosphatized and powder painted including earthing as reqd. (But without MCB/RCCB/Isolator) i ii iii iv v vi 4 way (4 + 12), Single door, horizontal type 6 way (4 + 18), Single door, horizontal type 8 way (4 + 24), Single door, horizontal type 4 way (4 + 12), double door, horizontal type 6 way (4 + 18), double door, horizontal type 8 way (4 + 24), double door, horizontal type 820.00 959.00 1388.00 1311.00 1634.00 1803.00 Each Each Each Each Each Each 0.00 0.00 0.00 0.00 0.00 0.00
2.34 Supplying and fixing following way single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with loose wire box, terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections including powder coat painting, earthing as reqd. (But without MCB/RCCB/Isolator) i ii iii iv v vi 4 way, Single door 8 way, Single door 12 way, Single door 4 way, double door 8 way, double door 12 way, double door 1795.00 2329.00 2863.00 2526.00 3192.00 4100.00 Each Each Each Each Each Each 0.00 0.00 0.00 0.00 0.00 0.00
2.35 Supplying, installation, testing and commissioning of surface/ recess mounting, verticle type, 415 volts, TPN MCB distribution board sheet steel dust protected duly phosphatized and powder painted, inclusive of 200 amps tinned copper busbar, common neutral link, earth bar, din bar for mounting NCB's, detachable gland/ knock out plate and with 100 amps. 10 KA MCCB as incomer, interconnection between incomer MCCB and busbars of following ways etc. as reqd. (But without MCB's) i 4 way with 100 amps MCCB as incomer ii 8 way with 100 amps MCCB as incomer iii 12 way with 100 amps MCCB as incomer 2992.00 Each 3553.00 Each 4070.00 Each 0.00 0.00 0.00
MCB's
2.51 Supplying and fixing 5 amps. to 32 amps rating, 240 volts, 'B' series,miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i ii iii iv Single pole Single pole and neutral Triple pole Triple pole and neutral 86.00 171.00 273.00 352.00 Each Each Each Each 0.00 0.00 0.00 0.00
2.52 Supplying and fixing 5 amps. to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for indeuctive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i Single pole ii Single pole and neutral iii Triple pole iv Triple pole and neutral 2.53 Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as reqd. 2.54 Supplying and fixing following rating , double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 amps ii 63 amps 2.55 Supplying and fixing following rating , four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i 40 amps ii 63 amps iii 100 amps 2.56 Supplying and fixing following rating double pole (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. i 25 amps ii 40 amps iii 63 amps 2.57 Supplying and fixing following rating four pole (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. i 25 amps ii 40 amps iii 63 amps
2.00 Each
0.00
0.00 0.00
2.61 Supplying and fixing 10 amp 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 10 amp 'C' series SP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket out let & complete with connections, testing and commissioning etc. as reqd.
509.00 Each
0.00
2.62 Supplying and fixing 20 amp 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top along with 20 amp 'C' series SP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket out let & complete with connections, testing and commissioning etc. as reqd.
520.00 Each
0.00
2.63 Supplying and fixing 20 amp 240 V, TPN industrial type socket outlet with 4 pole and earth, metal enclosed plug top along with 20 amp 'C' series TP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket out let & complete with connections, testing and commissioning etc. as reqd. 2.64 Supplying and fixing 30 amp 240 V, TPN industrial type socket outlet with 4 pole and earth, metal enclosed plug top along with 30 amp 'C' series TP MCB in sheet steel enclosure on surface or in recess, with chained metal cover for the socket out let & complete with connections, testing and commissioning etc. as reqd.
1073.00 Each
0.00
1294.00 Each
0.00
2.71 Providing and fixing MV danger notice plate of 200mm X 150mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as reqd. 2.72 Providing and fixing HT danger notice plate of 250mm X 200mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as reqd.
68.00 Each
0.00
75.00 Each
0.00
No.
Description of item
Qty
Rate
Unit
3.1 Earthing with GI earth pipe 4.5 mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as reqd. 3.2 Earthing with GI earth pipe 4.5 mtr long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as reqd. 3.3 Extra for using salt and charcoal for pipe earth electrode as reqd 3.4 Extra for using salt and coke for pipe earth electrode as reqd 3.5 Earthing with GI earth plate 600mm x 600 mm x 6mm thick Including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as reqd. 3.6 Earthing with copper earth plate 600mm x 600 mm x 3mm thick Including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as reqd. 3.7 Extra for using salt and coke for GI or copper pipe earth electrode as reqd 3.8 Extra for using salt and coke for GI or copper pipe earth electrode as reqd 3.9 Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as reqd. 3.10 Supplying and laying 6 SWG copper wire at 0.50 metre below ground level for conductor earth electrode including soldering etc. as reqd. 3.11 Supplying and laying 25mm X 5mm GI strip at 0.50 mettre below ground as strip earth electrode, including soldering etc. as reqd. 3.12 Supplying and laying 25mm X 6mm GI strip at 0.50 metre below ground as strip earth electrode, including soldering etc. as reqd. 3.13 Providing and fixing 25 x 5 mm copper strip in 40mm dia. GI pipe from earth electrode as reqd. 3.14 Providing and fixing 25 x 5 mm GI strip in 40mm dia. GI pipe from earth electrode as reqd.
1496.00 Set
1971.00 Set
475.00 Set
1063.00 Set
1585.00 Set
3263.00 Set
603.00 Set
1484.00 Set
41.00 Metre
16.00 Metre
45.00 Metre
60.00 Metre
494.00 Metre
218.00 Metre
3.15 Providing and laying earth connection from earth electrode with 6 SWG dia GI Wire in 15 mm dia GI pipe from earth electrode as reqd. 3.16 Providing and laying earth connection from earth electrode with 4.00 mm dia copper Wire in 15 mm dia GI pipe from earth electrode as reqd. 3.17 Providing and fixing 25 x 5 mm copper strip on surface or in recess for connections etc. as reqd. 3.18 Providing and fixing 25 x 5 mm GI strip on surface or in recess for connections etc. as reqd. 3.19 Providing and fixing 6 SWG dia GI Wire on surface or in recess for loop earthing as reqd. 3.20 Providing and fixing 4.00 mm dia copper Wire on surface or in recess for loop earthing as reqd. 3.21 Providing and Fixing 6 SWG dia GI wire on surface or in recess for loop eatrhing along with existing surface/recessed conduit/ submain wiring/ cable as reqd. 3.22 Providing and Fixing 4.00 mm dia copper wire on surface or in recess for loop eatrhing along with existing surface/recessed conduit/ submain wiring/ cable as reqd. 3.23 Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections as reqd.
86.00 Metre
111.00 Metre
358.00 Metre
66.00 Metre
24.00 Metre
49.00 Metre
11.00 Metre
36.00 Metre
665.00 Metre
Amount
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
No.
Description of item
Qty
Rate
Unit
4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as reqd. 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, GI tube, having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as reqd. 4.3 Fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube/ GI tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as reqd.
477.00 Each
243.00 Each
90.00 Each 4.4 Reverting, sweating and soldering of copper / GI tape ( with another copper / GI tape, base of the finial or any other metalic object) as reqd. 4.5 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surfaceof wall for lightning conductor complete as reqd. (For Horizontal run) 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surfaceof wall for lightning conductor complete as reqd. (For Vertical run) 4.7 Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surfae of wall for lightning conductor complete as reqd.( For horizontal run ) 4.8 Providing and fixing GI tape 20 mm X 3 mm thick on parapet or surfae of wall for lightning conductor complete as reqd.( For vertical run ) 4.9 Fixing of copper/ GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as reqd.( For horizontal run) 4.10 Fixing of copper/ GI tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as reqd.( For vertical run) 4.11 Providing and fixing testing joint, made of 20 mm X 3mm thick copper strip, 125 mm long, with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as reqd 4.12. Providing and fixing testing joint, made of 20 mm X 3mm thick GI strip, 125 mm long, with 4 nos. of GI bolts, nuts, check nuts and spring washers etc. complete as reqd 4.13 Providing and laying copper tape 32 mm X 6 mm from earth electrode directly in ground as reqd. 4.14 Providing and laying GI tape 32 mm X 6 mm from earth electrode directly in ground as reqd.
56.00 Each
163.00 Metre
175.00 Metre
31.00 Metre
43.00 Metre
15.00 Metre
27.00 Metre
108.00 Each
37.00 Each
475.00 Metre
65.00 Metre
4.15 Laying copper/ GI tape 32 mm X 6 mm from earth electrode directly in ground as reqd.
13.00 Metre
Amount
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00