St r e n g t h a n d v e r s a t i l i t y o f s l o t t e d a n g l e

Solve your special storage problems with ease and strength using Edsals painted
or galvanized slotted angle
Easy to use Just measure, cut and bolt together
Custom build benches, carts, scaffolds, storage racks, platforms almost
anything you need at a minimum cost
Unlimited combinations

Scientifically patterned holes and slots for bolting


pieces together at various angles without drilling holes
No special tools required
Prime, cold rolled steel with painted or hot dipped
galvanized finish for rust resistance
Available in 120" and 144" lengths in 14 gauge and
12 gauge steel
Includes 75 zinc-plated 3/8" 16" x 3/4" HexHead
Bolts and Nuts
Heavy duty bolts and nuts assure a strong, rigid
structure for a lifetime of use
100% reusable use short pieces of angle as a cleat
to join shorter angle lengths into longer ones by
bolting together
Disassemble one structure and assemble a new one

This product is available in:


industrial gray
steel components
galvanized
steel components

SPECIFICATIONS
When planning your slotted angle structure, be sure to use the capacities shown in the tables
below. All capacities are for static vertical loading. At least two bolts must be used for all
connections. Overlap should be a minimum of 9" when splicing two members together.

LOADING
DIRECTION
T-SECTION

GA
14
12
14
12
14
12
14
12
14
12
14
12
14
12

3 FT
331
621
441
590
772
1,400
1,418
2,799
1,860
3,735
2,621
4,707
3,146
5,850

4 FT
230
450
316
421
527
909
1,070
2,061
1,365
2,664
1,884
3,615
2,232
4,538

5 FT

362
210
294
397
631
761
1,540
1,018
2,064
1,491
2,917
1,799
3,621

6 FT

197
306
499
613
1,236
806
1,704
1,227
2,430
1,477
3,096

7 FT

235
374
466
970
657
1,413
1,022
2,048
1,266
2,705

8 FT

173
270
362
762
540
1,161
851
1,765
1,119
2,352

9 FT 10 FT

212

284
257
567
430
455
352
951
777
727
633
1,546 1,386
1,004 900
2,073 1,812

3 FT
2,302
3,308
4,917
7,482
5,139
8,069
9,849
14,963
10,269
16,565

4 FT
1,899
2,775
4,527
6,807
4,860
7,734
9,021
13,622
9,707
15,998

5 FT
1,526
2,165
3,974
6,080
4,505
7,329
7,965
12,168
9,009
15,237

6 FT
1,188
1,602
3,342
5,214
4,091
6,897
6,683
10,434
8,168
14,382

7 FT
806
1,251
2,739
4,235
3,623
5,871
5,486
8,481
7,250
13,082

8 FT

900
2,385
3,396
3,096
5,277
4,770
6,795
6,174
12,254

9 FT

2,208
3,137
2,587
4,622
4,419
6,273
5,171
11,012

I-SECTION

SINGLE BEAM

WIDE CHANNEL
SECTION

TL-SECTION
I-SECTION

WIDE SECTION

To determine safe allowable


load per column, use longest
vertical space between
horizontal brace.

UPRIGHT SECTION
C-SECTION

(Vertical Posts)
In pounds each section

Size
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"

height
T-SECTION

LOAD CAPACITIES
WHEN USED AS
UPRIGHTS

WIDE CHANNEL
SECTION

SINGLE BEAM

Combination sections are bolted


together on 6" centers.
Capacities based on uniformly
distributed load. For concentrated
loads, use half these figures.

T-SECTION

(Horizontal Members)
In pounds each section

SINGLE BEAM

LOAD CAPACITIES WHEN


USED AS BEAMS

SINGLE BEAM

span

Size
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"
11/2" x 21/4"
11/2" x 3"

GA
14
12
14
12
14
12
14
12
14
12

10 FT

2,214
2,129
3,902
4,140
4,428
4,253
9,567

Note: CAUTION: All loads given are based on uniform loading. Consideration must be