RTC80.7XX(09) Weely Programming

thermostat
Daily use of the thermostat

Mounting lnstructions

RTC80.7XX hleely Programmi ng thermostat Weekly circulation, it is possible to set 6 periods called events each day with different temperatures, also you can select "manual mode" or "comfort mode" according to your individual requirements. The thermostat is recommended for th6 control of electric heating devices or on/off valve actuator used in water-based heating systems.

1) menu

umu

2) 3)

Selection Table:
Model
RTC80.713 RTC80.723 RTC80.716

Current
3A 3A 16A

Application
For control of electric actuator or electrothermal actuator For control of electric actuator or electrothermal actuator For control of heatinq cable or other heatinq equipments

Technical data:

Voltage

Power consumption Setting range Limitation range Switching differential Ambient temperature Protective housing Housing material Floor sensor

:2W
:

AC230V(AC110V I AC24V available)


4

plus "4" & minus ov" Press the "4" or \" key to increase or decrease your set value clock "O" Press the "O" key to set the time and day press the 19" key till the day start blinking, use the "A" or "v" key to setthe day, press the "O" key to confirm the setting and the hours start blinking, use the "1" or "V" key to set the hburs, press the "f or Y to confirm the setting and the minutes start blinking, use the "A" or "V" key to set the minutes, press the "0" key to accept the settings

"ffi" key to select manual mode or clock-controlled programme mode, use the "A" or "v" key to enter into comfort mode in clock-controlled programme mode
Press the

on/off

"(|)"

-90C :4"C -99C +0.5K


:
:

5C

(factory setting: 28"C-32"C1

-5-50C
sensor,

: lP20
: anti-flammable PC : rubber-thermoplastic NTC

Press the "t!)" key to switch on or switch off the thermostat the setted temperature and the time will be displayed on left side of screen alternately, and the room temperature can be directly read out on right side of screen

Programming: 6-event time and temperature


Press the "f,R" key for 5 seconds to begin programming

cable length is 3m
Fu

'8"

nction:
manual mode The scheduled event program is overridden, set the temperature according to your individual requirements an d the thermostatwill operate at this temperature permanently
The day has been split into 6 events, the thermostat will operate automatically according to the programmed temperature and time

Key

Event

Symbol

Time
Y

Temperature
20"c
o o
a
g)

A V

+
Or

06: 00

"O" clock-controlled programme mode

2 o
I

08' 00

15C 15C
15C
22"C

&
Oe

(n

4
5 6

s
( + (

11: 30 12- 30
172 00
222 00

o E o (a
0)

(t)

3 3 o o 3 o
l) g

ilf ,,

&"O" comfort mode


The temperature can be temporarily changed for a single event, the comfort mode temperature is reset at the next event, and the ther-

s
E)
I

o 5
CL

o-

3.

3 (D

15C
22"C

E
o

08: 00

ct)

23, 00

15C

GI ffi I ffi ., ffi ffi , ffi ffi ffi ffi ffi


;i+ ffi : ffi ffi ffi ffi ffi " '

wake-up, event

Leave (am), event 2

Note: 1) the pre-progratmmed setpoint (1 5T ) for event g & 4is the same as event 2, ple.ase resef it aciording to you individual requirement 2) symbol "off" will be displayed if the setpoint reachs the minimum sef value and the thermostaf r's snrifched.off in this event

Return (am)' event 3


Leave (pm), event 4

Advanced settings (qualified person preferred)


Press the " ffi' key simultaneously switching on the thermostat to enter into the advanced setting mode(when the device is switched off)
.

Return (pm), event 5 .steep, Heating on


event 6

Key

Symbol
1

Setting

A OrV lN
:

ADJ
SEN

lemperatu re cal ibratior Adjust measured tem perature

built-in sensor

"Key-lock" function is activated


Set sensor mode: built-in/floor/both sensors Set vacation operating mode

m
-:=

Sensor mode

OUT : floor sensor ALL : both sensor (floor sensor is the limit sensor)

Setting Max and Min allowed temperqtrr_1 Early-start adaptive function

o
s

3 4 5 6

HI

LO

Max. Limitation temperature setpoint (99C ) Min. Temperature Min. Limitation temperature setpoint (4C ) Max. Temperature

ADA PRG

Adaptive functidfi=
Set vacation mode Reset to

ON" : preheating-30

miw+erearly-

OFF: cancel adaptive function 2


1

Sensor calibration to ensure accurate temperature measurement Display with back light, stay on for 20 seconds LcD disptay for better read out display actual room temperature when switch-off

0 7

512 day mode 6/1 day mode 7 day mode

FAC

factory settings

Programming parameters wil I be reset to factory settings when symbol r'- - -r' appears

Sehsor failure:

"Key.;gck" function
Press both the "A" and "v" keys for 5 secs to engage/disengage the "key-lock" function ( 'fl' symbol appear means "key-lock" function is activated; disappear means "key-lock" function is deactivated)
HVAC CONTROLS PRODUCTS

Please select the right sensor mode when operation, it will display the oErr" symbol on screen for sensor failure, thermostat must be checked till the fault is eliminated

2010 E 80 1.0

*
,

RTC80.7XX(09\Weely,Programming
Explanation of

thermostet

,Mounting tnstruetions
..

symbols
Clock-controlled :prcgrapme mode

Event indicator Set value/time display Dav number Plus/ririnus key Menu key

ms.nualmode Actual teqr.perature


Kev loclt Hebting on

ot
@t

On/off switch Temperature Sensor Clock key

lnstallthe thermostat in electrical connection box with screws

Dimension

lnstall the housing cover and lock the externalframe

Mounting steps:

Wirins diaoram 5

/+
80.716 80.723

hJ"-

H
L1 N1

,\,

lv

NL
AC230V

,:;, =,,ffi J,
164 AC230V

-,-h ttt lll


3

n
L1

3g o Lrrr 3>
a
lf

ti
NL
AC230V 201CIE80 1.0

6 o

HVAC CONTROLS PRODUCTS

You might also like