You are on page 1of 16

GEN-X

superior performance
01 Gen-X

Environment control in mission critical space is a great concern in today’s


technology requirements. Therefore, the precision air conditioner plays an
important role in this environment.

The Citec GEN-X series of precision air conditioning system is the real
solution for critical space. It is designed for 24/7 and round the clock
operation. Quick reactions to drastic change in heat load always become
its main duty in order to prevent huge temperature fluctuation.

It is designed to meet the stringent demands of Tier IV data centers and


other critical space which provide energy efficient environmental control
in temperature, humidity and air filtration. The advance microprocessor
controls are compatible with a wide range of remote monitoring
systems.
P r e c is i o n E f f iciency C r eativity

GEN-X
03 Gen-X

The GEN-X series of air conditioning It is essential to carry out regular


system is compact and stylish with the maintenance for optimum performance.
highest performance. It is specially design Ease of maintenance has always been the
for medium and large data center. main concern in designing GEN-X. The
Genius Controller will automatically
The GEN-X series solve the increasing indicates when maintenance is required on
heat load problem in today’s valuable floor individual components and all servicing
space with the minimal footprint. In a can be carried out through the front doors
world that tolerates zero downtime, of the unit.
system availability is essential. With that in
mind, GEN-X is designed with the highest The GEN-X series is available in four (4)
quality components selected for proven ranges which designed and cater for
reliability. various market demands namely:

• Commander Range (Chilled Water


System)
• Deluxe Range (Dual Coil Chilled Water
System)
• Elegant Range (Air Cooled, Water
Cooled, Dual Coil Systems)
• Performer Range (Air Cooled and Water
Cooled Systems)

“GEN-X is designed with the highest quality


components selected for proven reliability”
04 Gen-X

3
4

1) Electrical Panel

2) Coil

3) Air Filter

4) Scroll Compressor

5) Electronic Expansion Valve

6) Belt Driven Fan

7) Heater
05 Gen-X

Commander Range (Chilled Water System)


The GEN-X Commander Range of Chilled Water air conditioning system
is designed with a minimal footprint and to meet the higher capacity
requirement.

• Capacity ranges from 55kW to 150kW

• Available in both upflow and downflow


configurations

• Cooling, humidification, dehumidification,


reheating, filtration

• Factory pre-piped, wired and tested

• Precisely control temperature and


humidity to ±1ºC and ±5%RH

Features

Coil Electrical panel Microprocessor control with in house


Large face area/low face velocity design for High Low voltage segregation and each program
precise control of cooling and components are protected by individual Built in auto-sequencing feature enables
dehumidification. MCB. High voltage compartment contains interfacing with most of the commonly
the contactors, miniature circuit breaker, used serial communication standards.
Belt driven fan blowers (downflow transformer and other components and With an optional interface card, it can be
system - forward or backward curve) protected by a separate over-current integrated into the most widespread BMS
Adjustable for higher static requirement. protective device. systems.

Plug fan blowers (upflow system – Air Filter Control and monitoring system
backward curve) Protect against airborne contaminants Prevent and reduce costly downtime
More efficient and less noise. within the critical environment which can duration with mature monitoring systems
damage storage media and charged that provide complete supervision all the
Optional EC fan electronics components. time on temperature and humidity.
Energy saving and efficient.
Touch screen display
Heaters Comes with a user friendly menu for ease
2-stage stainless steel heaters of finned of navigation. Displays graphical
design for extended life. Low watt density, information and status of trend and plotted
sheathed elements are made of stainless graphs for both temperature and humidity
steel with integral high efficiency fins, in 3 different languages namely English,
reducing sheath temperatures and Chinese and Thai.
eliminating ionization. It also keeps the
temperature from going too low during
dehumidification cycle.
06 Gen-X

Deluxe Range (Dual Coil Chilled Water System)


The GEN-X Deluxe Range of Dual Coil Chilled Water air conditioning system is designed to meet the
requirements of system availability in Tier IV data centers. The unit is designed specifically for dual chilled
water source application which is excellent in redundancy and availability.

• Capacity ranges from 60kW to 135kW Heaters Microprocessor control with in house
2-stage stainless steel heaters of finned program
• Available in both upflow and downflow design for extended life. Low watt density, Built in auto-sequencing feature enables
configurations sheathed elements are made of stainless interfacing with most of the commonly
steel with integral high efficiency fins, used serial communication standards.
• Cooling, humidification, dehumidification, reducing sheath temperatures and With an optional interface card, it can be
reheating, filtration eliminating ionization. It also keeps the integrated into the most widespread BMS
temperature from going too low during systems.
• Factory pre-piped, wired and tested dehumidification cycle.

• Precisely control temperature and Electrical panel


humidity to ±1ºC and ±5%RH High Low voltage segregation and each
components are protected by individual
Features MCB. High voltage compartment contains
the contactors, miniature circuit breaker,
Dual Chilled Water Coil transformer and other components and
Each with large face area/low face velocity protected by a separate over-current Control and monitoring system
design for precise control of cooling and protective device. Prevent and reduce costly downtime
dehumidification. duration with mature monitoring systems
which provide complete supervision all the
Belt driven fan blowers (downflow time on temperature and humidity.
system - forward or backward curve)
Adjustable for varying static requirement.

Plug fan blowers (upflow system –


backward curve)
More efficient and less noise.

Optional EC fan
Energy saving and efficient.
Air Filter
Protect against airborne contaminants
within the critical environment which can
damage storage media and charged
electronics components.

Touch screen display


Comes with a user friendly menu for ease
of navigation. Displays graphical
information and status of trend and plotted
graphs for both temperature and humidity
in 3 different languages namely English,
Chinese and Thai.
07 Gen-X

Elegant Range (Air Cooled, Water Cooled and Dual Coil Systems)
The GEN-X Elegant Range of Air Cooled, Water Cooled and Dual Coil air
conditioning systems are designed according to the stringent
requirement of data centers. It provides high sensible cooling to data
center in energy efficient way.

The Elegant Range is easily customizable for larger capacity and capable
for high external static pressure application. The dual coil options
provide redundancy and flexibility with dual cooling source thus enable
even higher energy efficiency.

• Capacity ranges from 50kW to 90kW Belt driven fan blowers (downflow Air Filter
system - forward or backward curve) Protect against airborne contaminants
• Available in both upflow and downflow
Adjustable for varying static requirement. within the critical environment which can
configuration
damage storage media and charged
• Cooling, humidification, dehumidification, Plug fan blowers (upflow system – electronics components.
reheating, filtration backward curve)
More efficient and less noise. Touch screen display
• Factory pre-piped, wired and tested
Comes with a user friendly menu for ease
• Precisely control temperature and of navigation. Displays graphical
humidity to ±1ºC and ±5%RH information and status of trend and plotted
graphs for both temperature and humidity
Features in 3 different languages namely English,
Chinese and Thai.
Scroll compressor (twin circuit)
Efficient and reliable performance with a Microprocessor control with in house
robust design which concern on quiet program
operation and continual smooth compression Built in auto-sequencing feature enables
process. The discharge gas and vibration are interfacing with most of the commonly
kept at a low level. It has internal vibration EC fan as option used serial communication standards.
isolation mountings, pressure safety controls Energy saving and efficient. With an optional interface card, it can be
and built-in overload protection gives integrated into the most widespread BMS
excellent durability. Heaters systems.
2-stage stainless steel heaters of finned
Coil design for extended life. Low watt density, Control and monitoring system
Large face area/low face velocity design for sheathed elements are made of stainless Prevent and reduce costly downtime
precise control of cooling and steel with integral high efficiency fins, duration with mature monitoring systems
dehumidification. reducing sheath temperatures and which provide complete supervision all the
eliminating ionization. It also keeps the time on temperature and humidity.
Electronic expansion valve temperature from going too low during
Provide fast and precise response to changes dehumidification cycle.
in room condition which gives more stable
unit operation and save energy at low load Electrical panel
condition. The real time superheat monitoring High Low voltage segregation and each
enable early detection on refrigerant leakage, components are protected by individual
at the same time ensures proper refrigerant MCB. High voltage compartment contains
charge. the contactors, miniature circuit breaker,
transformer and other components and
protected by a separate over-current
protective device.
08 Gen-X

Performer Range (Air Cooled and Water Cooled Systems)


The GEN-X Performer Range of Air Cooled and Water Cooled air conditioning systems are compact and
stylish. It is designed to achieve highest performance with a minimal foot print. It also solves the increasing
heat load problem in today’s valuable floor space.

• Capacity ranges from 60kW to 120kW Coil Electrical panel


Large face area/low face velocity design High Low voltage segregation and each
• Available in both upflow and downflow
for precise control of cooling and components are protected by individual
configuration
dehumidification. MCB. High voltage compartment contains
• Cooling, humidification, dehumidification, the contactors, miniature circuit breaker,
reheating, filtration transformer and other components and
protected by a separate over-current
• Factory pre-piped, wired and tested
protective device.
• Precisely control temperature and
humidity to ±1ºC and ±5%RH Air Filter
Protect against airborne contaminants
Features within the critical environment which can
damage storage media and charged
Scroll compressor (twin circuit) electronics components.
Efficient and reliable performance with a
robust design which concern on quiet Electronic expansion valve Touch screen display
operation and continual smooth Provide fast and precise response to Comes with a user friendly menu for ease
compression process. The discharge gas changes in room condition which gives of navigation. Displays graphical
and vibration are kept at a low level. It has more stable unit operation and save information and status of trend and plotted
internal vibration isolation mountings, energy at low load condition. The real time graphs for both temperature and humidity
pressure safety controls and built-in superheat monitoring enable early in 3 different languages namely English,
overload protection gives excellent detection on refrigerant leakage, at the Chinese and Thai.
durability. same time ensures proper refrigerant
charge. Microprocessor control with in house
program
Belt driven fan blowers (downflow Built in auto-sequencing feature enables
system - forward or backward curve) interfacing with most of the commonly
Adjustable for varying static requirement used serial communication standards.
With an optional interface card, it can be
Plug fan blowers (upflow system – integrated into the most widespread BMS
backward curve) systems.
More efficient and less noise.
Control and monitoring system
Optional EC fan Prevent and reduce costly downtime
Energy saving and efficient. duration with mature monitoring systems
which provide complete supervision all the
Heaters time on temperature and humidity.
2-stage stainless steel heaters of finned
design for extended life. Low watt density,
sheathed elements are made of stainless
steel with integral high efficiency fins,
reducing sheath temperatures and
eliminating ionization. It also keeps the
temperature from going too low during
dehumidification cycle.
09 Gen-X

Commander Range

Technical Specifications

Models CXD / U_ _ _ 55 60 75 90 100 130 140 150

Airflow m³/s 4.2 5.0 5.0 5.8 6.7 6.7 7.4 8.4
m³/hr 15120 18000 18000 20880 24120 24120 26640 30240

Total kW 59.96 70.98 81.40 95.92 110.46 122.26 134.00 152.66


Sensible kW 53.96 64.00 71.28 83.66 96.06 103.64 114.28 130.04
S.H.R. - 0.90 0.90 0.88 0.87 0.87 0.85 0.85 0.85
CW Flow Rate I/s 2.86 3.40 3.90 4.58 5.28 5.84 6.40 7.30
Unit Pressure Drop kPa 84.00 90.10 58.20 83.20 111.90 89.90 54.80 72.70

Electric Reheat

No. of Steps - 2 2 2 2 3 3 3 4
Capacity kW 12 18 18 18 27 27 27 36

Humidifier

Humidifier Capacity kg/hr 8 15 15 15 15 15 15 15


Capacity Power kW 6.00 11.25 11.25 11.25 11.25 11.25 11.25 11.25

Connections

Chilled Water In mm 42 42 54 54 63 63 63 63
Chilled Water Out mm 42 42 54 54 63 63 63 63
Humidifier Feed mm 15 15 15 15 15 15 15 15
Drain mm 22 22 22 22 22 22 22 22

Dimensions

Unit Depth mm 885 885 885 885 885 885 885 885
Width mm 1550 1800 1800 2050 2300 2300 2550 2800
Height mm 1954 1954 1954 1954 1954 1954 1954 1954
Weight kgs 455 535 570 785 850 890 935 980

Note: All the cooling performances are based on Air On: 24˚C, 45%RH

Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
10 Gen-X

Deluxe Range
Technical Specifications

Models DXD / U _ _ _ 60 70 80 95 120 135

Airflow m³/s 4.2 5.0 5.8 6.7 8.4 9.2


m³/hr 15120 18000 20880 24120 30240 33120

Total kW 59.96 70.98 83.50 93.78 120.08 132.56


Sensible kW 53.96 64.00 75.02 84.70 108.14 119.08
S.H.R. - 0.90 0.90 0.90 0.90 0.90 0.90
CW Flow Rate I/s 2.86 3.40 3.98 4.48 5.74 6.34
Unit Pressure Drop kPa 84.00 90.10 77.30 64.70 79.70 99.40

Electric Reheat

No. of Steps - 2 2 2 3 3 4
Capacity kW 12 18 18 27 27 36

Humidifier

Humidifier Capacity kg/hr 8 15 15 15 15 15


Capacity Power kW 6.00 11.25 11.25 11.25 11.25 11.25

Connections

Chilled Water In mm 42 54 54 54 63 63
Chilled Water Out mm 42 54 54 54 63 63
Humidifier Feed mm 15 15 15 15 15 15
Drain mm 22 22 22 22 22 22

Dimension

Unit Depth mm 885 885 885 885 885 885


Width mm 1550 1800 2050 2300 2800 3050
Height mm 1954 1954 1954 1954 1954 1954
Weight kgs 455 535 570 785 850 890

Note: All the cooling performances are based on Air On: 24˚C, 45%RH

Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
11 Gen-X

Elegant Range
Technical Specifications

Models EXD / U _ _ A / W / DA / DW 50 65 70 80 90
Airflow m³/s 3.5 4.2 5.0 5.8 6.7
m³/hr 12600 15120 18000 20880 24120

“A” Version
Total kW 49.55 56.85 70.02 74.54 87.23
Sensible kW 44.10 51.43 62.57 68.53 79.44
S.H.R. - 0.89 0.90 0.89 0.92 0.91

Connections
Air Cooled CACR 326 326 506 506 506
Condensers Model
Liquid Line inch 5/8” 5/8” 3/4” 3/4” 7/8”
Discharge Line inch 1 1/8” 1 1/8” 1 1/8” 1 1/8” 1 3/8’
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22
Compressors Model ZR108 ZR125 ZR144 ZR160 ZR190

“W” Version
Total kW 52.25 61.39 71.33 78.96 95.32
Sensible kW 45.62 54.02 63.29 71.36 84.74
S.H.R - 0.87 0.88 0.89 0.90 0.89
Connections
Water Cooled B10/60 B10/60 B10/80 B10/80 B80/60
Condensers Model
Condenser Water - mm 42 42 54 54 54
In / Out
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22
Chilled Water Coil Performance of “DA” and “DW” Version
Total kW 50.30 59.96 70.98 83.50 93.78
Sensible kW 45.20 53.96 64.00 75.02 84.70
S.H.R - 0.90 0.90 0.90 0.90 0.90
Water Flow Rate I/s 2.40 2.86 3.40 3.98 4.48
Connections
Chilled Water In mm 42 42 54 54 54
Chilled Water Out mm 42 42 54 54 54
Electric Reheat
No. of Steps - 2 2 2 2 3
Capacity kW 12 18 18 18 27
Humidifier
Humidifier Capacity kg/hr 8 15 15 15 15
Capacity Power kW 6.00 11.25 11.25 11.25 11.25

Dimension
Unit Depth mm 885 885 885 885 885
Width mm 1800 2050 2300 2550 2800
Height mm 1954 1954 1954 1954 1954
Weight kgs 620 725 810 910 985

Note: All the cooling performances are based on Air On: 24˚C, 45%RH
Due to our policy of continuous development and improvement, the specifications and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
12 Gen-X

Performer Range
Technical Specifications

Models PXD / U _ _ _ A / W 60 75 85 95 120

Airflow m³/s 3.5 4.2 5.0 5.8 6.7


m³/hr 12600 15120 18000 20880 24120

“A” Version

Total kW 58.00 72.29 77.07 91.78 116.12


Sensible kW 49.61 60.48 68.15 80.14 97.17
S.H.R - 0.86 0.84 0.84 0.87 0.84

Connections

Air Cooled CACR 326 506 506 506 756


Condensers Model
Liquid Line inch 3/4” 3/4” 3/4” 7/8” 7/8”
Discharge Line inch 1 1/8” 1 1/8” 1 1/8” 1 3/8” 1 3/8”
Humidifier Feed inch 15 15 15 15 15
Drain mm 22 22 22 22 22
Compressors Model ZR125 ZR144 ZR160 ZR190 ZR250

“W” Version

Total kW 62.79 74.01 81.51 98.82 123.72


Sensible kW 51.93 61.90 70.41 83.68 100.81
S.H.R - 0.83 0.84 0.84 0.87 0.84

Connections
Water Cooled B10/60 B10/80 B10/80 B80/60 B80/75
Condensers Model
Condenser Water - mm 42 54 54 54 63
In / Out
Humidifier Feed mm 15 15 15 15 15
Drain mm 22 22 22 22 22

Electric Heat

No. of Steps - 2 2 2 2 3
Capacity kW 12 18 18 18 27

Humidifier

Humidifier Capacity kg/hr 8 15 15 15 15


Capacity Power kW 6.00 11.25 11.25 11.25 11.25

Dimension

Unit Depth mm 885 885 885 885 885


Width mm 1800 2050 2300 2550 2800
Height mm 1954 1954 1954 1954 1954
Weight kgs 682 798 891 1084 1200

Note: All the cooling performances are based on Air On: 24˚C, 45%RH

Due to our policy of continuous development and improvement, the specifi cations and data herein are subject to change without notice. We must therefore reserve the right to supply
equipment that may differ from that described and illustrated herein. All information, including illustrations, contained in this brochure, is believed to be accurate and reliable. Users, however,
should independently evaluate the suitability of each product for their own application. CITEC makes no warranties as to the accuracy or completeness of the information, and disclaims any
liability regarding its use.
13 Gen-X

Notes
www.citec.com.my

Version 1.0 / 2008 / Gen-X 01

CITEC INTERNATIONAL SDN. BHD. (372827-H)


No. 47, (PT 63846), Lorong Jala 14/KS10, Telok Gong,
42000 Port Klang, Selangor Darul Ehsan, Malaysia.
Tel: 603-3134 2668 Fax: 603-3134 2648
Email: enquiry@citec.com.my

You might also like