1. Material Properties Concrete Compressive Strength, fc' Tensile Strength, fy Unit weight of concrete, wc Unit weight of soil, ws Allowable bearing capacity, qa 2. Trial Section Footing: Length Width Thickness Effective depth 3. Loadings From staad analysis: Column Load Footing Load, P

= = = = =

20.70 275.80 24.00 18.00 150.00

MPa MPa 3 kN/m 3 kN/m kPa

L = W = T = =

2.00 2.00 0.35 0.28

m m m m

Column Dimension: Width b = Thickness s = Depth of Soil D =

0.20 m 0.40 m 1.00 m

= 293.00 kN = Column load + Weight of Ftg. + Weight of soil = 397.16 kN

4. Check for Soil Bearing Capacity Soil Pressure, qact = P / Area of ftg 5. Determine the required reinforcement 5.1 Along long direction 2 Moment, M = qact (x )/2 where x = (L - b) Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*W*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use maximum steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm 5.2 Along short direction 2 Moment, M = qact (x )/2 where x = (W - s) Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*L*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm

99.29 kPa

< qa

OK!

= = 1.80 m = = = = = = = = = = = say, = = 1.60 m = = = = = = = = = = = say,

160.85 kN-m 16.00 201.06 50.00 282.00 15.67 1.12 0.00421 0.00508 0.00508
2 1.43 mm /mm 140.46 mm 100.00 mm

mm mm2 mm mm MPa

127.09 kN-m 16.00 201.06 50.00 282.00 15.67 0.89 0.00330 0.00508 0.00508
2 1.43 mm /mm 140.46 mm 100.00 mm

mm 2 mm mm mm MPa

DESIGN SHEET
PROJECT LOCATION ITEM : : : 2-STOREY RESIDENTIAL UNIT W/ ATTIC DESIGN OF EXTERIOR FOOTING 1 DESIGNED BY : CHECKED BY : FILENAME : ASL FOUNDATION

FOUNDATION /exterior-ftg1.xls Page 2 of 5

DATE DATE

: :

10/22/2013

1. Material Properties Concrete Compressive Strength, fc' Tensile Strength, fy Unit weight of concrete, wc Unit weight of soil, ws Allowable bearing capacity, qa 2. Trial Section Footing: Length Width Thickness Effective depth 3. Loadings From staad analysis: Column Load Footing Load, P

= = = = =

20.70 275.80 24.00 18.00 150.00

MPa MPa 3 kN/m 3 kN/m kPa

L = W = T = =

2.50 2.50 0.40 0.33

m m m m

Column Dimension: Width b = Thickness s = Depth of Soil D =

0.20 m 0.40 m 1.00 m

= 517.10 kN = Column load + Weight of Ftg. + Weight of soil = 688.16 kN

4. Check for Soil Bearing Capacity Soil Pressure, qact = P / Area of ftg 5. Determine the required reinforcement 5.1 Along long direction 2 Moment, M = qact (x )/2 where x = (L - b) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*W*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use maximum steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm 5.2 Along short direction 2 Moment, M = qact (x )/2 where x = (W - s) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*L*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm

110.11 kPa

< qa

OK!

= = 1.15 m = = = = = = = = = = = say, = = 1.05 m = = = = = = = = = = = say,

72.81 kN-m 16.00 201.06 50.00 332.00 15.67 0.29 0.00107 0.00508 0.00508
2 1.69 mm /mm 119.30 mm 100.00 mm

mm mm2 mm mm MPa

60.70 kN-m 16.00 201.06 50.00 332.00 15.67 0.24 0.00089 0.00508 0.00508
2 1.69 mm /mm 119.30 mm 100.00 mm

mm 2 mm mm mm MPa

DESIGN SHEET
PROJECT LOCATION ITEM : : : 2-STOREY RESIDENTIAL UNIT W/ ATTIC DESIGN OF EXTERIOR FOOTING 2 DESIGNED BY : CHECKED BY : FILENAME : ASL FOUNDATION

FOUNDATION /exterior-ftg2.xls Page 3 of 5

DATE DATE

: :

10/22/2013

1. Material Properties Concrete Compressive Strength, fc' Tensile Strength, fy Unit weight of concrete, wc Unit weight of soil, ws Allowable bearing capacity, qa 2. Trial Section Footing: Length Width Thickness Effective depth 3. Loadings From staad analysis: Column Load Footing Load, P

= = = = =

20.70 275.80 24.00 18.00 150.00

MPa MPa 3 kN/m 3 kN/m kPa

L = W = T = =

1.10 1.10 0.30 0.23

m m m m

Column Dimension: Width b = Thickness s = Depth of Soil D =

0.35 m 0.20 m 1.20 m

= 60.31 kN = Column load + Weight of Ftg. + Weight of soil = 93.65 kN

4. Check for Soil Bearing Capacity Soil Pressure, qact = P / Area of ftg 5. Determine the required reinforcement 5.1 Along long direction 2 Moment, M = qact (x )/2 where x = (L - b) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*W*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use maximum steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm 5.2 Along short direction 2 Moment, M = qact (x )/2 where x = (W - s) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*L*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm

77.39 kPa

< qa

OK!

= = 0.38 m = = = = = = = = = = = say, = = 0.45 m = = = = = = = = = = = say,

5.44 kN-m 16.00 201.06 50.00 232.00 15.67 0.10 0.00037 0.00508 0.00508
2 1.18 mm /mm 170.73 mm 150.00 mm

mm mm2 mm mm MPa

7.84 kN-m 16.00 201.06 50.00 232.00 15.67 0.15 0.00054 0.00508 0.00508
2 1.18 mm /mm 170.73 mm 150.00 mm

mm 2 mm mm mm MPa

DESIGN SHEET
PROJECT LOCATION ITEM : : : 2-STOREY RESIDENTIAL UNIT W/ ATTIC DESIGN OF EXTERIOR FOOTING 3 DESIGNED BY : CHECKED BY : FILENAME : ASL FOUNDATION

FOUNDATION /exterior-ftg2.xls Page 4 of 5

DATE DATE

: :

10/22/2013

1. Material Properties Concrete Compressive Strength, fc' Tensile Strength, fy Unit weight of concrete, wc Unit weight of soil, ws Allowable bearing capacity, qa 2. Trial Section Footing: Length Width Thickness Effective depth 3. Loadings From staad analysis: Column Load Footing Load, P

= = = = =

20.70 275.80 24.00 18.00 150.00

MPa MPa 3 kN/m 3 kN/m kPa

L = W = T = =

1.50 1.10 0.30 0.23

m m m m

Column Dimension: Width b = Thickness s = Depth of Soil D =

0.35 m 0.20 m 1.20 m

= 112.23 kN = Column load + Weight of Ftg. + Weight of soil = 158.24 kN

4. Check for Soil Bearing Capacity Soil Pressure, qact = P / Area of ftg 5. Determine the required reinforcement 5.1 Along long direction 2 Moment, M = qact (x )/2 where x = (L - b) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*W*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use maximum steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm 5.2 Along short direction 2 Moment, M = qact (x )/2 where x = (W - s) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*L*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm

95.90 kPa

< qa

OK!

= = 0.58 m = = = = = = = = = = = say, = = 0.45 m = = = = = = = = = = = say,

15.85 kN-m 16.00 201.06 50.00 232.00 15.67 0.30 0.00109 0.00508 0.00508
2 1.18 mm /mm 170.73 mm 150.00 mm

mm mm2 mm mm MPa

9.71 kN-m 16.00 201.06 50.00 232.00 15.67 0.13 0.00049 0.00508 0.00508
2 1.18 mm /mm 170.73 mm 150.00 mm

mm 2 mm mm mm MPa

DESIGN SHEET
PROJECT LOCATION ITEM : : : 2-STOREY RESIDENTIAL UNIT W/ ATTIC DESIGN OF WALL FOOTING DESIGNED BY : CHECKED BY : FILENAME : ASL FOUNDATION DATE DATE

FOUNDATION /wall-ftg.xls Page 5 of 5

: :

10/22/2013

1. Material Properties Concrete Compressive Strength, fc' Tensile Strength, fy Unit weight of concrete, wc Unit weight of soil, ws Allowable bearing capacity, qa 2. Trial Section Footing: Length Width Thickness Effective depth Depth of Soil 3. Loadings Column Load Footing Load, P

= = = = =

20.70 275.80 24.00 18.00 192.00

MPa MPa 3 kN/m kN/m3 kPa

L = W = T = = D =

1.00 0.60 0.20 0.132 1.20

m m m m m

Column Dimension: Width b = Thickness s =

m m

= 31.65 kN = Column load + Weight of Ftg. + Weight of soil = 47.49 kN

4. Check for Soil Bearing Capacity Soil Pressure, qact = P / Area of ftg 5. Determine the required reinforcement 5.1 Along long direction (temperature bars) Bar diameter to be used: Bar area: Clear cover: Total reinforcement area: As = 0.002bt Quantitiy of bars using 16 mm 5.2 Along short direction 2 Moment, M = qact (x )/2 where x = (W - s) / 2 Bar diameter to be used: Bar area: Clear cover: Provided depth: m=fy/0.85fc` Ru=Mdes/(f*L*depth2) Required steel ratio: r=1/m{1-sqrt[1-2*mRu/fy)]} Minimum steel ratio: (1.4/fy) Use steel ratio: Total reinforcement area: As = r*depth Spacing of bars using 16 mm

79.15 kPa

< qa

OK!

= = = = = say, =

16.00 mm 2 201.06 mm 50.00 mm


2 400.00 mm 1.99 mm 3 pcs

6.33 kN-m 16.00 201.06 50.00 132.00 15.67 0.40 0.00148 0.00508 0.00508
2 0.670 mm /mm 300.07 mm 200.00 mm

0.40 m = = = = = = = = = = = say, mm mm2 mm mm MPa