Model Dimensions (mm) Display Generator Voltage Measurement Mains Voltage Measurement Generator Power Measurement Load Current Measurement Earth Current Measurement Outputs
EAOM-210.FD EAOM-210.FL EAOM-210.FDJ** EAOM-210.FLJ** 144x204 LED L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N KVAh, kWh, kVA, kW, kVAr, kVarh Yes Yes Start, Fuel, Horn, Mains Open and Close, Generator Open and Close 4 User Configurable 144x204 LCD (Graphic) L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N KVAh, kWh, kVA, kW, kVAr, kVarh Yes Yes Start, Fuel, Horn, Mains Open and Close, Generator Open and Close 4 User, Configurable +8 conf. w/expansion board 6 User, Configurable +8 conf. w/expansion board Relay Oil Pressure Fuel Level Temperature From Alternator signal or magnetic pickup Operator & Technician Real Time Timer Yes Yes Last 32 events
Messenger 144x204 LCD (Graphic) L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N KVAh, kWh, kVA, kW, kVAr, kVarh Yes Yes Start, Fuel, Horn, Mains Open and Close, Generator Open and Close 4 User, Configurable
Messenger.Pro 144x204 LCD (Graphic) L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N KVAh, kWh, kVA, kW, kVAr, kVarh Yes Yes Start, Fuel, Horn, Mains Open and Close, Generator Open and Close 4 User, Configurable
Configurable Outputs
Configurable Inputs
2 User Configurable
2 User Configurable
2 User Configurable
6 User Configurable
6 User, Configurable
6 User, Configurable
Relay No
Relay No
Transistor No
Relay Oil Pressure Fuel Level Temperature From Alternator signal or magnetic pickup Operator & Technician Real Time Timer Yes Yes Last 50 events
Relay Oil Pressure Fuel Level Temperature From Alternator signal or magnetic pickup Operator & Technician Real Time Timer Yes Yes Last 32 events
Relay Oil Pressure Fuel Level Temperature From Alternator signal or magnetic pickup Operator & Technician Real Time Timer Yes Yes Last 32 events on device and all events archived on PC Yes RS-232 ModBus ASCII, Standard Modem Ethernet, Internet
From Alternator signal or magnetic pickup Operator & Technician Timer Yes No No
From Alternator signal or magnetic pickup Operator & Technician Timer Yes No No
Two Level Passwords Timer Engine Running Time Programmable Working Timer Event Logs
No No
No RS-232 Serial
**only available in **only available in FDJ FLJ RS-232 ModBus RTU, Standard Modem RS-232 ModBus ASCII, Standard Modem
GSM
send/receive
Real-time technology allows for real-time feedback - Know the status of your generator instantly! Only a text message away...
sends alarm informations to pre-defined GSM numbers via internal GSM modem. User may control the device, CLEAR alarms, RESET, change MODEs, STOP, START, access the PARAMETERs of device, change the parameters and enquire information about generators active status by sending and receiving SMS. Accessing and trouble shooting of the Gen-Sets outside of residental area & all around the world is possible.
Sender +905305227470 Generator No3: 03.07.2008 16:08:12 Level Prealarm Back Options
#1:read s?
Sender +905305227470 Generator No3: AUTO, Engine is not running, Load from mains
#1:read c1
Options
Send
Options
Back
Options
Send
Options
Back
#1:read h235
#1:read r20
Options
Send
Options
Back
Options
Send
Options
Send
Options
Back
Order information MESSENGER Enhanced automatic Gen Set controller with transfer switching, SMS communication by build-in internal GSM modem and configuration software
ADSL Modem
SMS
GSM
.PRO enables continuous communication with build in ethernet and dial-up modem facility. Gen-Agent SCADA software offers remote control & visualisation and maintenance management of multiple Gen-Sets from a central computer via internet by ADSL connected to telephone or local ethernet network. Software also observes for alarms and archieves them. The failures and alarms traced by Gen-Agent SCADA software can be sent to 3 GSM numbers pre-defined in software for your information.
Order information MESSENGER.PRO Enhanced automatic Gen-Set controller with transfer switching, Build-in Ethernet & Dial-up modem communication, multiple Gen-Set visualisation & control by Gen-Agent SCADA software
+Vbat
-Vbat
-Vbat
E.Stop
5 6 configurable digital inputs 8-32Vdc 4 configurable relay outputs Supply voltage Phone line
MESSENGER.PRO
XCell
Ethernet
GSM modem
Mains
3 phase mains and 3 phase generator voltage measurement, 3 phase load current and earth current measurement, Contactor open and close relay outputs for mains and generator, Configurable 6 inputs and 4 outputs, 3 resistive sender inputs for oil pressure, temperature and level, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Programmable weekly working permit calendar, Maintenance warning (working hour or elapsed month), Exercise at programmed time intervals, OFF, Manual, Auto and Test mode, Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh, Compatible to Diesel or Gas generators
Level
Start
EAOM-210.FL
Remote control via RS-232 ModBus or dial-up modem, Authorised access, secure communication, Automatic transfer switching control and engine control, Logs last 32 events & alarm informations, Full metering facility, energy and power measurement, 3 phase mains and 3 phase generator voltage measurement, 3 phase load current and earth current measurement, Contactor open and close relay outputs for mains and generator, Configurable 6 inputs and 4 outputs, Optional configurable 8 inputs and 8 outputs with Expansion I/O Board, 3 resistive sender inputs for oil pressure, temperature and level, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Programmable weekly working permit calendar, Maintenance warning (working hour or elapsed month), Exercise at programmed time intervals, OFF, Manual, Auto and Test mode, Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh, Compatible to Diesel or Gas generators, 144x204 mm size, Flat type
Pre-Alarm Engine temperature Over / Under voltage Over / Under frequency Over / Under speed Oil pressure Fuel level Warning & Electrical trip Earth fault Over current Short circuit Alarm Mains breaker not opened Mains breaker not closed Generator breaker not opened Generator breaker not closed Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Preheat External alarm horn
Fail Monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage failure Charging fail Spare-1, 2, 3 Error Spare-4, 5, 6 Over / Under speed Speed loss Earth fault Fuel level Battery low Battery high Maintenance Over current Short circuit Engine stop
EAOM-210.FL
8 configurable digital inputs Optional Expansion I/O Board 8 configurable EAOM-210.FL.EXR relay outputs
D+(W.L.)
-Vbat
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Battery voltage
EAOM-210.FL
Generator
Contactor open / close
Communication
RS-232 ModBus ASCII
Mains
Level
Start
D+(W.L.)
E.Stop
Digital inputs
Engine Control
Battery voltage
EAOM-210.FL.S
Generator Mains
Communication
RS-232 ModBus ASCII
Level
Start
Contactor Contactor
Order information EAOM-210.FL EAOM-210.FL.S EAOM-210.FL-EXR MODEM-EXR ENCV-232/485-EXR EAOM-210.FL-SOFT EAOM-210.FL.S-SOFT Enhanced automatic Gen-Set controller with transfer switching, LCD display Automatic Gen-Set controller with transfer switching, LCD display I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FL) 8-32Vdc supply voltage RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FL), 1000V galvanic insulation, 8-32Vdc supply voltage PC Communication software for Remote control and Programming PC Communication software for Remote control and Programming
EAOM-210.FLJ
CanBus J1939 ECU communication
CanBus J1939 ECU communication Remote control via RS-232 ModBus or dial-up modem, Authorised access, secure communication, Automatic transfer switching control and engine control, Logs last 32 events & alarm informations, Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2 Power factor measurement for 3 phases SPN, FMI and OC values reading from engine via J1939 3 phase mains and 3 phase generator voltage measurement, 3 phase load current and earth current measurement, Contactor open and close relay outputs for mains and generator, Configurable 6 inputs and 4 outputs, Optional configurable 8 inputs and 8 outputs with Expansion I/O Board, 3 resistive sender inputs for oil pressure, temperature and level, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Programmable weekly working permit calendar, Maintenance warning (working hour or elapsed month), Exercise at programmed time intervals, OFF, Manual, Auto and Test mode, Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh, Compatible to Diesel or Gas generators, 144x204 mm size, Flat type
Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Preheat External alarm horn Alarm Mains breaker not opened Mains breaker not closed Generator breaker not opened Generator breaker not closed Warning & Electrical trip Earth fault Over current Short circuit Pre-Alarm Engine temperature Over / Under voltage Over / Under frequency Over / Under speed Oil pressure Fuel level Fail Monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage failure Charging fail Spare-1, 2, 3 Error Spare-4, 5, 6 Over / Under speed Speed loss Earth fault Fuel level Battery low Battery high Maintenance Over current Short circuit Engine stop
EAOM-210.FLJ
CanBus J1939 ECU communication
8 configurable digital inputs Optional Expansion I/O Board 8 configurable EAOM-210.FL.EXR relay outputs
D+(W.L.)
-Vbat
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Relay Analogue inputs outputs
Battery voltage Temperature Oil Pressure Solenoid
EAOM-210.FLJ
Generator
Contactor open / close
Communication
RS-232 ModBus ASCII
Mains
Level
Start
D+(W.L.)
E.Stop
Digital inputs
Engine Control
Relay Analogue inputs outputs
Battery voltage Temperature Oil Pressure Solenoid
EAOM-210.FLJ.S
Generator Mains
Communication
RS-232 ModBus ASCII
Level
Start
Contactor Contactor
Order information EAOM-210.FLJ EAOM-210.FLJ.S EAOM-210.FL-EXR MODEM-EXR ENCV-232/485-EXR EAOM-210.FLJ-SOFT EAOM-210.FLJ.S-SOFT Enhanced automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm. Automatic Gen-Set controller with transfer switching, LCD display, J1939 ECU comm. I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FLJ) 8-32Vdc supply voltage RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FLJ), 1000V galvanic insulation, 8-32Vdc supply voltage PC Communication software for Remote control and Programming PC Communication software for Remote control and Programming
10
EAOM-210.FD
Remote control via RS-232 ModBus or dial-up modem, Authorised access, secure communication, Automatic transfer switching control and engine control, Logs last 50 events & alarm informations, Full metering facility, energy and power measurement, 3 phase mains and 3 phase generator voltage measurement, 3 phase load current and earth current measurement, Contactor open and close relay outputs for mains and generator, Configurable 6 inputs and 4 outputs, 3 resistive sender inputs for oil pressure, temperature and level, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Maintenance warning (working hour or elapsed month), Exercise at programmed time intervals, OFF, Manual, Auto and Test mode, Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh, Compatible to Diesel or Gas generators, 144x204 mm size, Flat type
Pre-Alarm Engine temperature Over / Under voltage Over / Under frequency Over / Under speed Oil pressure Fuel level Warning & Electrical trip Reverse power Earth fault Over current Short circuit Alarm Mains breaker not opened Mains breaker not closed Generator breaker not opened Generator breaker not closed Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Preheat External alarm horn
Fail Monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage failure Charging fail Spare-1, 2, 3 Error Spare-4, 5, 6 Over / Under speed Speed loss Earth fault Fuel level Battery low Battery high Maintenance Over current Short circuit Engine stop
11
EAOM-210.FD
D+(W.L.)
-Vbat
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Battery voltage
EAOM-210.FD
Generator
Contactor open / close
Mains
D+(W.L.)
-Vbat
Level
Start
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Battery voltage
EAOM-210.FD.S
Generator Mains
Contactor Contactor
Communication
RS-232 ModBus ASCII or RTU
Order information EAOM-210.FD EAOM-210.FD.S MODEM-EXR ENCV-232/485-EXR EAOM-210.FD-SOFT EAOM-210.FD.S-SOFT Enhanced automatic Gen-Set controller with transfer switching, LED display Automatic Gen-Set controller with transfer switching, LED display V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage PC Communication software for Remote control and Programming PC Communication software for Remote control and Programming
Level
Start
12
EAOM-210.FDJ
CanBus J1939 ECU communication
CanBus J1939 ECU communication Remote control via RS-232 ModBus or dial-up modem, Authorised access, secure communication, Automatic transfer switching control and engine control, Logs last 50 events & alarm informations, Remote Start/Stop, Speed and Idle mode control via J1939 for Volvo EMS2 Power factor measurement for 3 phases SPN, FMI and OC values reading from engine via J1939 3 phase mains and 3 phase generator voltage measurement, 3 phase load current and earth current measurement, Contactor open and close relay outputs for mains and generator, Configurable 6 inputs and 4 outputs, 3 resistive sender inputs for oil pressure, temperature and level, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Maintenance warning (working hour or elapsed month), Exercise at programmed time intervals, OFF, Manual, Auto and Test mode, Power measurement by kVA, kW, kVAr, kVAh, kWh, kVArh, Compatible to Diesel or Gas generators, 144x204 mm size, Flat type
Pre-Alarm Engine temperature Over / Under voltage Over / Under frequency Over / Under speed Oil pressure Fuel level Warning & Electrical trip Reverse power Earth fault Over current Short circuit Alarm Mains breaker not opened Mains breaker not closed Generator breaker not opened Generator breaker not closed Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Preheat External alarm horn
Fail Monitoring Emergency stop Multiple engage fail Failed to start Low oil pressure High temperature Speed failure Voltage failure Charging fail Spare-1, 2, 3 Error Spare-4, 5, 6 Over / Under speed Speed loss Earth fault Fuel level Battery low Battery high Maintenance Over current Short circuit Engine stop
13
EAOM-210.FDJ
CanBus J1939 ECU communication
D+(W.L.)
-Vbat
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Relay Analogue inputs outputs
Battery voltage Temperature Oil Pressure Solenoid
EAOM-210.FDJ
Generator
Contactor open / close
Mains
D+(W.L.)
-Vbat
Level
Start
Charge Gen.
E.Stop
+Vbat
-Vbat
Digital inputs
Engine Control
Relay Analogue inputs outputs
Battery voltage Temperature Oil Pressure Solenoid
EAOM-210.FDJ.S
Generator Mains
Contactor Contactor
Communication
RS-232 ModBus ASCII or RTU
Order information EAOM-210.FDJ EAOM-210.FDJ.S MODEM-EXR ENCV-232/485-EXR EAOM-210.FDJ-SOFT EAOM-210.FDJ.S-SOFT Enhanced automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm. Automatic Gen-Set controller with transfer switching, LED display, J1939 ECU comm. V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FD) 8-32Vdc supply voltage RS-232 / RS-485 Convertor unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-210.FD), 1000V galvanic insulation, 8-32Vdc supply voltage PC Communication software for Remote control and Programming PC Communication software for Remote control and Programming
Level
Start
14
EAOM-9F
Remote control via RS-232 or standard modem communication, Automatic transfer switching control and engine control, 3 phase mains and 1 phase generator voltage measurement, Contactor transistor outputs for mains and generator, Configurable 2 inputs and 1 output, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Maintenance warning (working hour), OFF, Manual, Auto and Test mode, 144x204 mm size, Flat type
-Vbat High temperature
Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Mains and Generator contactor Preheat External alarm horn
Charge Gen.
2
2 configurable digital inputs
Configurable output
Horn Output
E.Stop
Monitors 3-phase mains voltage Alternator voltage Alternator frequency Engine speed Battery voltage Engine running time Error indication Program parameters
D+(W.L.)
-Vbat
-Vbat
Digital inputs
Engine Control
Batery voltage
Transistor outputs
Transistor outputs
Communication
RS-232
Generator
Contactor
Mains
Contactor
Fail Monitoring Failed to start Low oil pressure High temperature Over speed failure Voltage failure Charging fail Over Current Spare-1, 2
Order information EAOM-9F MODEM-EXR EAOM-9F-SOFT Automatic Gen-Set controller with transfer switching, LED display V.32bis / 14.000bps Dial-up Modem unit, DIN rail mounting type, including 2m RS-232 cable (for connection to RS-232 port of EAOM-9F) 8-32Vdc supply voltage PC Communication software for Remote control and Programming
Solenoid
Start
15
EAOM-9
Automatic transfer switching control and engine control, 3 phase mains and 1 phase generator voltage measurement, Contactor relay outputs for mains and generator, Configurable 2 inputs and 1 output, Speed sensing from alternator voltage or magnetic pickup, Stop or fuel solenoid selection, Maintenance warning (working hour), OFF, Manual, Auto and Test mode, 96x96 mm size,
-Vbat High temperature -Vbat Low oil pressure
D+(W.L.)
Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Mains and Generator contactor Preheat External alarm horn
Monitors 3-phase mains voltage Alternator voltage Alternator frequency Engine speed Battery voltage Engine running time Error indication Program parameters
-Vbat
Charge Gen.
-Vbat
Digital inputs
Engine Control
Batery voltage
Configurable output
Horn Output
E.Stop
Relay outputs
Solenoid
Generator
Contactor
Mains
Contactor
Fail Monitoring Failed to start Low oil pressure High temperature Over speed failure Voltage failure Charging fail Over Current Spare-1, 2
Order information EAOM-9 EAOM-9-SOFT Automatic Gen-Set controller with transfer switching, LED display PC Communication software for Remote control and Programming
Start
16
EAOM-19
Automatic transfer switching control and engine control, 3 phase mains and 1 phase generator voltage measurement, Contactor relay outputs for mains and generator, Configurable 2 inputs and 1 output, Speed sensing from alternator voltage, Stop and fuel solenoid selection, OFF, Manual, Auto and Test mode, Diesel or Gasoline engine control, Remote inhibit input, Adjustable choke time, Low oil level or pressure input, Provides charge generator excitation current, Easy to use and economical, 72x72 mm size,
Controls Fuel and Stop solenoid Starter motor Automatic generator start Load transfer to mains Mains and Generator contactor External alarm horn
Monitors 3-phase mains voltage Alternator voltage Alternator frequency Engine speed Battery voltage Error indication Program parameters
Digital inputs
Engine Control
Relay outputs
Solenoid Start Batery voltage
Fail Monitoring Failed to start Low oil pressure High temperature Over speed failure Voltage failure Charging fail Over Current Spare-1, 2
D+(W.L.)
Charge Gen.
-Vbat
Configurable output
Mains
Contactor
Order information EAOM-19 Automatic Gen-Set controller with transfer switching, LED display
17
Comparison Table
Model Dimensions (mm) Display Generator Voltage Measurement Generator Power Measurement Load Current Measurement Earth Current Measurement Outputs Configurable Outputs Configurable Inputs Outputs Type Analogue Resistive Sender Inputs Speed Sensing
EAOM-7 96x96 LED L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N kVA
EAOM-71 96x96 LED L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N kVA
EAOM-72F 144x204 LED L1/L2, L1/N L2/L3, L2/N L3/L1, L3/N kVA
No
No
No
IL1
No
No
No
No
No
2 User Configurable
3 User Configurable
3 User Configurable
3 User Configurable
3 User Configurable,
Relay No
Relay No
From Alternator signal From Alternator signal From Alternator signal From Alternator signal or magnetic pickup or magnetic pickup or magnetic pickup or magnetic pickup Operator & Technician Timer Yes Operator & Technician Timer Yes Operator & Technician Timer Yes Operator & Technician Timer Yes
RS-232 Serial
RS-232 Serial
RS-232 Serial
RS-232 Serial
RS-232 Serial
18
EAOM-72F
Automatic engine control, 3 phase generator voltage measurement, 3 phase Load current measurement, Generator power measurement by kVA, 3 Resistive sender inputs for Temperature, Oil Pressure and Level, Configurable 3 inputs and 2 outputs, Remote Start/Stop input, Speed sensing from alternator voltage or magnetic pickup, Over / Under speed warning and shutdown, Stop or fuel solenoid selection, Solenoid output switched negative or positive supply, Maintenance warning, 144x204 mm size, Flat type
-Vbat High temperature -Vbat Low oil pressure -Vbat Remote Start / Stop
D+(W.L.)
Controls Fuel and Stop solenoid Starter motor Automatic generator start/stop Preheat External alarm horn
Charge Gen.
E.Stop
Digital inputs
Engine Control
Battery voltage Magnetic Pickup (RPM) Temperature Oil Pressure
2 Configurable outputs
Horn Output
Monitors 3-phase alternator voltage 3-phase load current Alternator frequency Engine speed Generator Power (kVA) Oil pressure Engine temperature Fuel level Battery voltage Engine running time Error indication Program parameters
-Vbat
-Vbat
Analogue inputs
Communication Generator
RS-232
Fail Monitoring Alternator voltage & frequency Failed to start Low oil pressure High temperature Over / Under speed failure Over current Charging fail Emergency stop Maintenance due Spare-1, 2, 3
Order information EAOM-72F EAOM-72F-SOFT Auto Start Gen-Set protection and controller, LED display PC Communication software for Remote control and Programming
Level
19
EAOM-71
Automatic engine control, 3 phase generator voltage measurement, 1 phase Load current measurement, Generator power measurement by kVA, 3 Resistive sender inputs for Temperature, Oil Pressure and Level, Configurable 3 inputs and 2 outputs, Remote Start/Stop input, Speed sensing from alternator voltage or magnetic pickup, Over / Under speed warning and shutdown, Stop or fuel solenoid selection, Maintenance warning, 96x96 mm size,
-Vbat High temperature -Vbat Low oil pressure -Vbat Remote Start / Stop
D+(W.L.)
Controls Fuel and Stop solenoid Starter motor Automatic generator start/stop Preheat External alarm horn
Digital inputs
Engine Control
Battery voltage Magnetic Pickup (RPM)
2 Configurable output
Horn Output
Monitors 3-phase alternator voltage 1-phase load current Alternator frequency Engine speed Generator Power (kVA) Oil pressure Engine temperature Fuel level Battery voltage Engine running time Error indication Program parameters
-Vbat
Charge Gen.
E.Stop
-Vbat
Relay outputs
Temperature Solenoid
Analogue inputs
Oil Pressure
Communication Generator
RS-232
Fail Monitoring Alternator voltage & frequency Failed to start Low oil pressure High temperature Over / Under speed failure Over current Charging fail Emergency stop Maintenance due Spare-1, 2, 3
Order information EAOM-71 EAOM-71-SOFT Auto Start Gen-Set protection and controller, LED display PC Communication software for Remote control and Programming
Level
Start
20
EAOM-7
Automatic engine control, 3 phase generator voltage measurement, 3 phase Load current measurement, Generator power measurement by kVA, Configurable 3 inputs and 2 outputs, Remote Start/Stop input, Speed sensing from alternator voltage or magnetic pickup, Over / Under speed warning and shutdown, Stop or fuel solenoid selection, Maintenance warning, 96x96 mm size,
-Vbat Remote Start / Stop
Controls Fuel and Stop solenoid Starter motor Automatic generator start/stop Preheat External alarm horn
2 Configurable output
Charge Gen.
Horn Output
Monitors 3-phase alternator voltage 3-phase load current Alternator frequency Generator power (kVA) Engine speed Battery voltage Engine running time Error indication Program parameters
D+(W.L.)
-Vbat
E.Stop
-Vbat
Digital inputs
Engine Control
Relay outputs
Solenoid Start
Analogue inputs
Battery voltage
Communication Generator
IL1, IL2, IL3
RS-232
Fail Monitoring Alternator voltage & frequency Failed to start Low oil pressure High temperature Over / Under speed failure Over current Charging fail Emergency stop Maintenance due Spare-1, 2, 3
Order information EAOM-7 EAOM-7-SOFT Auto Start Gen-Set protection and controller, LED display PC Communication software for Remote control and Programming
21
EAOM-6
Automatic engine control, 3 phase generator voltage measurement, Configurable 3 inputs and 2 outputs, Remote Start/Stop input, Speed sensing from alternator voltage or magnetic pickup, Over / Under speed warning and shutdown, Stop or fuel solenoid selection, Maintenance warning, 96x96 mm size,
Controls Fuel and Stop solenoid Starter motor Automatic generator start/stop Preheat External alarm horn
Monitors 3-phase alternator voltage Alternator frequency Engine speed Battery voltage Engine running time Error indication Program parameters
-Vbat 2 Configurable output Horn Output
D+(W.L.)
Charge Gen.
-Vbat E.Stop
Digital inputs
Engine Control
Magnetic Pickup (RPM)
Relay outputs
Solenoid Start
Analogue inputs
Battery voltage
Communication
RS-232
Generator
Fail Monitoring Alternator voltage & frequency Failed to start Low oil pressure High temperature Over / Under speed failure Charging fail Emergency stop Maintenance due Spare-1, 2, 3
Order information EAOM-6 EAOM-6-SOFT Auto Start Gen-Set protection and controller, LED display PC Communication software for Remote control and Programming
22
EAOM-36
Controls Fuel and Stop solenoid Starter motor Automatic generator start/stop Preheat External alarm horn
Remote start / stop capability with zero power consumption, Designed for Generator, Pump and Fire Pump applications, Automatic engine control, Automatic shutdown on fault condition Generator frequency measurement, Configurable 2 inputs and 1 output, Remote Start/Stop input, Speed sensing from alternator voltage, Over / Under speed warning and shutdown, Stop or fuel solenoid selection, 72x72 mm size
Monitors Alternator frequency Engine speed Engine running time Error indication Program parameters
Fail Monitoring Failed to start Low oil pressure High temperature Over / Under speed failure Charging fail Spare-1, 2
D+(W.L.)
D+(W.L.)
-Vbat
-Vbat
for EAOM-36.RF
for EAOM-36.TF
for EAOM-36.R
Charge Gen.
for EAOM-36.T
Configurable output
Configurable output
Charge Gen.
Configurable output
-Vbat
Digital inputs
Engine Control
for EAOM-36.R Relay outputs for EAOM-36.T Solid state outputs
Digital inputs
Engine Control
for EAOM-36.RF Relay outputs for EAOM-36.TF Solid state outputs
relay output
relay output
Solenoid
Solenoid
Solenoid
L1,N
Solenoid
Generator
Generator
L1,N
Start
Start
Start
Start
Order information EAOM-36.R EAOM-36.T EAOM-36.RF EAOM-36.TF Auto Start Gen-Set protection and controller, LED display, with relay outputs Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT) Auto Start Gen-Set protection and controller, LED display, with relay outputs and fail safe inputs Auto Start Gen-Set protection and controller, LED display, with solid state outputs (pulling to -BAT) and fail safe inputs
23
-Vbat
Configurable output
EAOM-3
Automatic shutdown on fault condition, Alarm and status information, Auxiliary shutdown input, Provides charge alternator excitation current, Over speed protection option with tachometer metering output, Optional tamper-proof elased time meter, Optional stop button, 72x72mm size
-Vbat Aux2 input for STP series
Controls Fuel and Stop solenoid Starter motor Manual generator start/stop Preheat
Charge Gen.
Fail Monitoring Low oil pressure High temperature Over speed failure Charging fail
tachometer output (0...1mA) for ALT and MAG series
D+(W.L.)
Digital inputs
Engine Control
Solenoid Preheat Start
Order information Overspeed sensing from generator voltage Overspeed sensing from magnetic pickup Time meter Stop button Stop/Fuel selection Preheat Aux.In-1 Aux.In-2
+ + +
+ + + + + +
+ + + + + + + + + + + + + + + + + +
+ + + + + + + + + + + + + +
+ +
+ +
+ +
+ +
+ +
+ +
+ + +
24
EAOM-3-HM-STP-MAG
EAOM-3-HM-STP-ALT
EAOM-3-STP-MAG
EAOM-3-HM-MAG
EAOM-3-STP-ALT
EAOM-3-HM-STP
EAOM-3-HM-ALT
EAOM-3-MAG
Product codes
EAOM-3-STP
EAOM-3-ALT
EAOM-3-HM
EAOM-3
ATS-10
3 phase Mains voltage measurement, Single phase Generator voltage measurement, Optional Load Generator input, Optional engine running input, Mains voltage failure detection, Remote start output, Emergency backup and Test mode, Password protection, 72x72 mm size,
Monitors 3-phase mains voltage Alternator voltage Program parameters Controls Generator remote start Load transfer to mains Mains and Generator contactor
Load Generator
+Vbat
Engine running
+Vbat
Digital inputs
Generator
Contactor
Mains
Contactor
25
EAOM-210.FL.EXR
8 Configurable digital inputs Selectable input signal hardware type (-Ve or +Ve) Selectable input signal polarity (Close or Open to activate) User selectable 21 defined input configurations for each input 8 Configurable relay outputs Selectable output polarity (NO or NC) User selectable 93 defined functions for each output DIN Rail mounting type Communication to EAOM-210.FL, EAOM-210.FL.S, EAOM-210.FLJ or EAOM-210.FLJ.S by CanBus connection 8-32Vdc supply voltage
Order information EAOM-210.FL-EXR I/O Expansion Board which is DIN rail mounting type, including 2m CanBus cable
26
Battery Charger
GENCHARGER
3A or 5A output for 12Vdc and 24Vdc battery 115Vac or 230Vac supply voltage Short circuit and over current protection Reverse connection protection Boost output for quick charging Durability for voltage fluctuation Flame resistance plastic box
Order information GENCHARGER-312E GENCHARGER-312A GENCHARGER-512E GENCHARGER-512A GENCHARGER-324E GENCHARGER-324A GENCHARGER-524E GENCHARGER-524A SMPS Battery Charger, 3A Output for 12Vdc battery, 230Vac supply voltage SMPS Battery Charger, 3A Output for 12Vdc battery, 115Vac supply voltage SMPS Battery Charger, 5A Output for 12Vdc battery, 230Vac supply voltage SMPS Battery Charger, 5A Output for 12Vdc battery, 115Vac supply voltage SMPS Battery Charger, 3A Output for 24Vdc battery, 230Vac supply voltage SMPS Battery Charger, 3A Output for 24Vdc battery, 115Vac supply voltage SMPS Battery Charger, 5A Output for 24Vdc battery, 230Vac supply voltage SMPS Battery Charger, 5A Output for 24Vdc battery, 115Vac supply voltage
27
Company Profile
EMKO ELEKTRONIK A.S. has been engaged in the desing, manufacture and marketing of Measurement and Control Instruments and Temperature Sensors, as well as in providing the relevant before and after sales technical service since 1986. Giving the most importance to the customer-oriented approach and to product functionality and quality, we have carried out the design and manufacture of programmable multi-function process-control instruments, counters, time-relays, thermocouples and thermoresistances, control and protection generating system; gen-set controls, automatic transfer switching, manual-keystarts.
Our product range and service meet the needs of the textile, food, plastic, glass, automotive, chemicals, iron and steel, cement, machinery production, energy and other sectors, with regard to the automation and process-control materials and services that they require. Thanks to the quality policy and procedures issued by the management of our company, which processes in the TS ISO EN9001 Quality System Certificate, complete customer satisfaction in the areas of design, production and service is quaranteed. The design and manufacture of control devices conformed to the directives covered by the CE brand by performing the EMI, ESD, EFT, PQF, Surge, LVD, Environmental Conditions tests on new product designs in the test laboratories on our factory premises.
The following
- Process measurement and control instruments which conform to industrial standards - The measurement conversion and control of process parameters in such areas as temperature, pressure, weight, flow, level, speed, humidity, number, time, voltage and current etc. - Te m p e r a t u r e s e n s o r s , t h e r m o c o u p l e s a n d t h e r m o r e s i s t a n c e s - Control and protection generating systems; Gen-Set controls, Automatic Transfer Switchings, Manual-keystarts Our Customer Support Service provides pleasant, cheerful and sincere approach to ensure that our customers select the most suitable products by providing satisfactory and correct technical information before the sale and if the orders are delivered correctly on time by keeping track of orders within the company. Also, guarantees customer satisfaction at all times, in all places and under all circumstances by supplying them with speedy and reliable information through our authorized dealer and service network.
28