1. It is a structural system without complete vertical local carrying space frame. (NSCP 208.

20) Braced frame Bearing wall system Rigid component Concentric braced frame 2. Is a component including its attachments having fundamental period less than or equal to 0.06 sec. (NSCP 208.20) Braced frame Bearing wall system Rigid component Concentric braced frame 3. Is a component including its attachments having fundamental period greater than 0.60 sec. (NSCP 208.20) Braced frame Bearing wall system Rigid component Concentric braced frame 4. Concrete filled driven piles of uniform section shall have a nominal outside diameter of not less than (NSCP 307.7.3) 200 mm 250 mm 300 mm 350 mm 5. A complete record of test of materials and of concrete shall be available for inspection during the progress of work and _______ years after completion of the project and shall be preserved by the inspecting engineer or architect for that purpose, (NSCP 403.20) 2 years 5 years 10 years 15 years 6. The minimum bend diameter for 10mm through 25mm bars (NSCP 407.30) 12 db 6 db 8 db 10 db 7. The minimum bend diameter for 28mm through 36mm bars (NSCP 407.30) 12 db 6 db 8 db 10 db 8. The minimum clear spacing between parallel bars in a layer must be db but not less than? (NSCP 407.7.3) 50mm 25mm 75mm 100mm

9. In spirally reinforced or tied reinforced compression members, clear distance between longitudinal bars shall not be less than? (NSCP 407.7.3) 2.0 db 2.15 db 1.50 db 1.75 db 10. In walls and slabs other than concrete joist construction, primary flexural reinforcement shall not be spaced farther apart than 3 times wall or slab thickness nor farther than? (NSCP 407.7.5) 375mm 450mm 500mm 300mm 11. Groups of parallel reinforcing bars bundled in contact to act as one unit shall be united to ___ pieces in one bundle. (NSCP 407.7.6.1) 4 3 2 5 12. Bars larger than ___mm shall not be bundled in beams: (NSCP 407.7.6.3) 25mm 16mm 28mm 36mm 13. Individual bars within a bundle terminated within the span of flexural members shall terminate at different points with at least ____ stagger: (NSCP 407.7.6.4) 12 db 10 db 50 db 40 db 14. Minimum concrete cover cast against and permanently exposed to earth: (NSCP 407.8.1) 100 mm 75 mm 50 mm 150 mm 15. The minimum clear concrete covering for cast in place slab: (NSCP 407.8.1) 20mm 25mm 40mm 50mm 16. In ultimate strength design, the strength reduction factor for flexure without axial loads: (NSCP 409.2.1) 0.85 0.75 0.90 0.70

17. In ultimate strength design, the strength reduction factor for shear and torsion: (NSCP 409.4.2.3) 0.70 0.75 0.85 0.90 18. The minimum one way slab thickness which is simply supported at the ends only is: (NSCP 409.6.2) L/20 L/24 L/28 L/10 19. The minimum one way slab thickness for a ONE end continuous slab is: (NSCP 409.6.2) L/20 L/24 L/10 L/28 20. The minimum one way slab thickness for a BOTH ends continuous slab is: (NSCP 409.6.2) L/20 L/24 L/10 L/28 21. The minimum cantilevered slab thickness is : (NSCP 409.6.2) L/20 L/24 L/10 L/28 22. Deep continuous flexural members has overall depth to clear span ratio greater than: (NSCP 410.8.10) 0.40 0.60 0.75 0.70 23. Deep simple span flexural members has overall depth to clear span ratio greater than: (NSCP 307.4.2) 0.40 0.60 0.75 0.70 24. Spacing of shear reinforcement placed perpendicular to axis of non-prestressed member shall not exceed: (NSCP 411.6.4.1) d/2 d/4 d d/5 25. Development length Ld for deformed bars in tension shall be less than: (NSCP 412.3.1) 300 mm 250 mm

26.

27.

28.

29.

30.

31.

32.

200 mm 350 mm Is an essentially vertical truss system of the concentric or eccentric type that is provided to resist lateral forces: (NCSP 208.1) Building frame system Braced frame Diaphragm Collector Is a horizontal or nearly horizontal system activity to transmit lateral forces to the vertical resisting elements: Building frame system Braced frame Diaphragm Collector Is a frame in which members and joints are capable of resisting forces primarily by flexure: Moment resisting frame Ordinary braced frame Truss Eccentric braced frame In the determination of seismic dead load with a minimum of ________% of floor live load shall be applicable for storage and warehouse occupancies. (NSCP 208.5.1.1) 50% 25% 30% 35% The slope of cut surfaces shall be no steeper than _______% slope. (NSCP 302.2.2) 50% 60% 30% 40% Before commencing the excavation work, the person making the excavation shall notify in writing the owner of the adjoining building not less than _____days before such excavation is to be made. (NSCP 302.2.4) 15 days 10 days 30 days 60 days Fill slopes shall not be constructed on natural slopes steeper than ____% slope (NSCP 302.3.1) 50% 10% 20% 60%

33. The minimum distance that the toe of fill slope made to the site boundary line: (NSCP 302.4.3) 0.80 M 0.60 M 1.50 M 2.00 M 34. The max. distance that the toe of fill slope made to the site boundary: (NSCP 302.4.3) 0.80 M 0.60 M 6.00 M 1.00 M 35. In using sand backfill in the annular space around column not embedded in poured footings, the sand shall be thoroughly compacted by tamping in layers not more than _____mm in depth? (NSCP 305.7.3) 500 mm 400 mm 200 mm 300 mm 36. In using a concrete backfill in the annular space around column not embedded in poured footings, the concrete shall have ultimate strength of ____Mpa at 28 days. (NSCP 305.7.3) 30 Mpa 15 Mpa 10 Mpa 5 Mpa 37. When grillage footings of structural steel shapes are used on soils, they shall be completely embedded in concrete. Concrete cover shall be at least _____mm on the bottom. (NSCP 305.8) 100 mm 200 mm 150 mm 38. Temporary open air portable bleachers may be supported upon wood sills or steel plates placed directly upon the ground surface, provided soil pressure does not exceed ____Kpa. (NSCP 305.9) 100 Kpa 50 Kpa 150 Kpa 200 Kpa 39. The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 2 seismic area in the Philippines. (NSCP 305.60) 10mm 12mm 16mm 20mm 40. The minimum nominal diameter of steel bolts when wood plates or sill shall be bolted to foundation wall in zone 4 seismic area in the Philippines. (NSCP 305.60) 10mm 12mm 16mm

41.

42.

43.

44.

45.

46.

47.

20mm Individual pile caps and caissons of every structure subjected to seismic forces shall be interconnected by ties. Such ties shall be capable of resisting in tension or compression a minimum horizontal force equal to _____% of the largest column vertical load. (NSCP 306.20) 15% 20% 10% 25% Such piles into firm ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20) 1.50 M 2.00 M 2.50 M 3.00 M Such piles into soft ground may be considered fixed and laterally supported at _____M below the ground surface. (NSCP 306.20) 1.50 M 2.00 M 2.50 M 3.00 M The maximum length of cast in place piles/bored piles shall be _____times the average diameter of the pile. (NSCP 307.2.1) 10 times 20 times 30 times 15 times Cast in place/bored piles shall have a specific compressive strength Fc of not less than ______Mpa. (NSCP 307.2.1) 17.50 Mpa 20 Mpa 15 Mpa 25 Mpa Pre-cast concrete piles shall have a specific compressive strength Fc of not less than _____Mpa. (NSCP 304.7.1) 17.50 Mpa 20 Mpa 15 Mpa 25 Mpa The maximum spacing of ties and spirals in a driven pre-cast concrete pile center to center. (NSCP 307.5.1) 75 mm 100 mm 125 mm 150 mm

48. Pre-cast pre-stressed concrete piles shall have a specified compressive strength Fc of not less than ____Mpa. (NSCP 307.5.1) 20 Mpa 15 Mpa 25 Mpa 35 Mpa 49. The minimum outside diameter of pipe piles when used must be? (NSCP 307.6.3) 300 mm 250 mm 350 mm 400 mm 50. Aviation control towers fall to what type of occupancy? Special occupancy structures Essential facilities Hazardous facility Standard occupancy 51. Private garages, carports, sheds, agricultural buildings fall to what type of occupancy? Miscellaneous occupancy Essential facilities Special occupancy Hazardous facility 52. Buildings used for college or adult education with a capacity of 500 or more students fall to what type of occupancy? Miscellaneous occupancy Essential facilities Special occupancy Hazardous facility 53. Buildings or structures therein housing and supporting toxic or explosive chemicals or substances fall to what type of category? Miscellaneous occupancy Essential facilities Special occupancy Hazardous facility 54. The allowable deflection for any structural member loaded with live load only. (NSCP 107.2.2) L/300 L/360 L/200 L/240 55. The allowable deflection for any structural member loaded with dead load and live load only. (NSCP 104.2.2) L/240 L/300 L/360 L/200

56. Retaining walls shall be designed to resist sliding by at least _______times the lateral force. (NSCP 206.6) 3 2 1.50 1.0 57. Retaining walls shall be designed to resist overturning by at least ______times the overturning moment. (NSCP 206.6) 1.0 2.50 2.0 1.50 58. As per NSCP 2001 sect. 206.9.3 vertical impact force for crane load, if powered monorail cranes are considered, the max. wheel load of the crane shall be increased by what percent to determine the induced vertical impact? (NSCP 206.9.3) 50% 25% 15% 20% 59. The lateral force on a crane runway beam with electrically powered trolleys shall be calculated as ______% of the sum of the rated capacity of the crane and the weight of the hoist and trolley. (NSCP 206.9.4) 20% 15% 30% 50% 60. The longitudinal forces on crane runway beams, except for bridge cranes with hand geared bridges shall be calculated as _____% of the max. wheel load of the crane. (NSCP 206.9.5) 15% 10% 25% 20% 61. An open building is a structure having all walls at least _____% open. (NSCP 207) 50% 60% 80% 75% 62. Low rise buildings is an enclosed or partially enclosed with mean roof height less than or equal to? (NSCP 207.20) 70 M 50 M 15 M 18 M