MAIN MOTOR AND STARTER

CLIENT : ORDER / REF : PULPER :

Productos Tissue del Peru 0701052/01 PH25

COUNTRY: Peru

REMARK: Whatever the Pulper capacity may be, the essential priority concerning the choice of starting is that it must be able, in all cases, to generate a torque which is sufficient to drive the rotor at a restart after an unplanned or intentionnal stop with the pulper being full. For this reason, each time as possible, we strongly recommend the direct starting mode which supplies the highest torque. If this is not possible (power supply network is too weak), use of a starting system is required.

1.1 MOTOR CHOICE: Criteria to be respected Mounting arrangement: V1 1.2 STARTER CHOICE: Criteria to be respected

CD / CN >1

AND

Cmax / CN > 2

CD : Starting torque withh Full voltage CN: Nominal torque with full voltage Cmax: Maximum torque with full voltage

CDR > 0.4 CN


CDR : Starting torque with reduced voltage Minimum value below which pulper starting becomes problematic Starting time= 5s 4 start ups per hour, with 2 conscutive starts being spaced less than 20 secondes starting conditions: DIRECT (See starting curves (p 2/3 and 3/3)) REMARK: STAR / DELTA type starters are proscribed 1.3 MECHANICAL CHARACTERISTICS 1 Inertia of rotating masses, at the high speed (Motor shaft end) are respectively J1 for rotor only (empty pulper or with water)= 11 J2 for rotor and stock (operation consistency)= 33

kg.m kg.m

2 These figures are obtained by calculation so accurate possible. They are given using International System of units, i.e radius-mass. Mechanism and motor unit connection (pulleys or gearbox) are taken into account, but not motor inertia. 3 We give also, starting curves for which calculation assumptions are Inertia J1 and J2. Absobed torque in operation is about 20 and 80% of nominal (respectively for empty and full pulper). Hydraulic torque is a second power of rotation speed. A torque is needed at "zero-time" to "free" the pulp, when starting with full pulper. belt drive Gearbox 4 Motor unit connection: Driving an driven pulleys: / type: QVRG2 CUN.10 belt type and qty: Coupling: S16 /

NOTE you have to send us by return a "legible" motor sketch showing, without ambiguity, your final choice and the motor geometry; especially shaft end, possible flange, fixing lugs (holes), overall lenght and location of the terminal box must be perfectly determined. 1/3

SPO rev 1. 12/11/03 le 11/07/2007

PH25
Order / rf : Motor: 0701052/01 400 kW 1800 rpm Tn= 2122 N.m

Starting time 2 secondes


6000

5000

Torque (N.m)

4000

3000

2000

1000

0 0 2 4

Time (s)

Empty pulper starting torque empty pulper total torque

Empty pulper "hydraulic" torque full pulper total torque

full pulper "hydraulic" torque full pulper starting torque

Starting time 5 secondes


3500

3000

2500

Torque (N.m)

2000

1500

1000

500

0 0 5

time (s)
Empty pulper "hydraulic" torque full pulper total torque

10

Empty pulper starting torque full pulper "hydraulic" torque

full pulper starting torque empty pulper total torque

2/3

SPO rev 1. 12/11/03 le 11/07/2007

PH25
Order / rf : Motor: 0701052/01 400 kW 1800 rpm Tn= 2122 N.m

Starting time 10 secondes


3000

2500

Torque (N.m)

2000

1500

1000

500

0 0 2 4 6 8 10 12 14

Time (s)
Empty pulper starting torque full pulper "hydraulic" torque full pulper starting torque empty pulper total torque Empty pulper "hydraulic" torque full pulper total torque

full pulper T=f(N)


6000 1800

Empty pulper T=f(N)

1600 5000 1400

4000

1200

Torque (N.m)

Torque (N.m)
0 500 1000 N (rpm) 1500 2000

1000

3000

800

2000

600

400 1000 200

200

400

600

800

1000

1200

1400

1600

1800

2000

N (rpm)

full pulper total torque (t=2s) full pulper total torque (t=5s) full pulper total torque (t=10s)

empty pulper total torque (t=2s) empty pulper total torque (t=5s) empty pulper total torque (t=10s)

3/3