You are on page 1of 8

COMPARATIVE ANALYSIS OF PD 957 & BP 220

PARAMETER PD 957 OPEN MARKET HOUSING BP 220 ECONOMIC HOUSING


Above P150,000-P375,000 When suitable sites for housing & outside potential hazard prone & protection areas 3. LAND LOCATION Same as PD 957

1. MAXIMUM SELLING PRICE 2. PROJECT LOCATION

(Percentage of Gross Area


one hectare & above) a. Saleable Area b. Non-Saleable Area a. 70% Maximum a. 30% Minimum a. variable b. see open space requirement as per b.1 and b.3 b.1 Areas allocated for Parks & Playgrounds (1 Hectare & above) Density (No. of Lots/ Dwelling Units Per Hectare 20 & Below 21-25 26-35 36-50 51-65 Above 65 Mandatory Allocation for Parks and Playgrounds Per Tabulations Below % of Gross Area Allocated for Parks and Playgrounds 3.5% 4.0% 5.0% 6.0% 7.0% 9.0% 150 and below 151-160 161-175 176-200 201-225 Above 225 3.5% 4.0% 5.0% 6.0% 7.0% 9.0% Density (Dwelling Units per Hectare)

An addition of 1% Increment for every 10 or fraction thereof Above 225 NOTE: In no case shall the Area be less than 100 square meters Mandatory Allocation for Parks and Playgrounds Per Tabulations Below b.2 Area allocated for Community Facilities Variable Density (No. of Lots and/or Living Units Per Hectare) 150 & below 151-225 Above 225 b.3 Circulation System 4. MINIMUM LOT AREAS Single Detached Single Attached / Duplex / Semi-Detached Rowhouse 50 sq. meters (House & Lot) 35 sq. meters / unit NOTE: 1. Saleable lots designated as duplex and/or rowhouse lots shall be provided with housing components 2. Maintain a 60, 40 ratio for house and lot where 60% for the house and 40% for the lot (selling price for house&lot package) 100 sq. meter / unit 75 sq. meter / unit 72 sq. meter / unit 54 sq. meters / unit Observe Hierarchy of Roads 1.0% 1.5% 2.0%

Observe Hierarchy of Roads

BP 220
BP 220 SOCIALIZED HOUSING
P150,000 & Below Same as PD 957

a. variable b. see open space requirement as per b.1 and b.3

nds Per Tabulations Below % of Project Gross Area

150 and below 151-160 161-175 176-200 201-225 Above 225

3.5% 4.0% 5.0% 6.0% 7.0% 9.0%

every 10 or fraction thereof Above 225

nds Per Tabulations Below % of Project Gross Area

150 & below 151-225 Above 225

1.0% 1.5% 2.0%

Observe Hierarchy of Roads

72 sq. meters / unit 54 sq. meters / unit 32 sq. meters / unit

ed as duplex and/or rowhouse lots shall

ing components

o for house and lot where 60% for the

e lot (selling price for house&lot package)

PARAMETER

PD 957 OPEN MARKET HOUSING

BP 220 ECONOMIC HOUSING

5. MINIMUM LOT FRONTAGE 5.1 SINGLE DETACHED a. corner lot b. regular lot c. irregular lot 5.2 DUPLEX / SINGLE ATTACHED / SEMI DETACHED 5.3 ROWHOUSE 6. LENGTH OF BLOCK 3.5m 6.a maximum length is 400m. (for subdivision projects with lot component only 6.b blocks exceeding 250m. Shall provide alley NOTE: for ROWHOUSES, there shall be a maximum of 20 UNITS but in no case shall be more than 100m in length 7. ROADS RIGHT OF WAY (ROW) 7.1 Major 7.2 Minor 7.3 Motorcourt (Cul de sac, branch, loop, Tee 7.4 Alley 7.5 Footpath / Pathwalk 7.6 ROW of access to interior lot 3.0m 3.0m 4.0m 4.0m 3.0m 3.0m ROW 12m 10m 6.0m CARRIEGEWAY 8.0m 6.0m ROW 10m 8.0m 6.0m CARRIEGEWAY 6.0m 6.0m 5.0m 3.5m same as PD 957 12.m 10m 6m 7.5m 10m 8m 4m 6m

+ Right of way (ROW) of major roads shall be increased as project size increases. ROW shall not be lower than ROW of public road. + Major Roads shall maintain a uniform width of road right of way. Tapering of road width shall not be allowed NOTE: 1. Interior subdivision project must secure right of way to the nearest public road 2. Subdivision projects with direct access to a main public road must provide sufficient setback to accommodate loading and unloading of passengers. 3. Subdivision project shall provide provision for future expansion (see text) 8. MAXIMUM SIZES OF PROJECT PER HIERARCHY ROADS Project Size Range 2.5 hectares and below Above 2.5 - 5 hectares Above 10 - 15 hectares Above 15 - 30 hectares Above 30 hectares major road, minor road, motor court, alley same as above same as above same as above same as above same as above same as above same as above same as above major road, minor road, motor court, alley, footpath

BP 220 SOCIALIZED HOUSING

10m 8m 4m 6m

3.5m same as PD 957

in no case shall be more than 100m in length ROW 10.0m 8.0m 6.5m 6.0m 3.0m 3.0m 3.0m CARRIEGEWAY 6.0m 6.0m 5.0m

han ROW of public road.

ccommodate loading and unloading

or road, motor court, alley, footpath same as above same as above same as above same as above

PARAMETER

PD 957 OPEN MARKET HOUSING


(PS) (SW)

BP 220 ECONOMIC HOUSING


(PS) (SW)

9. ROAD SPECIFICATIONS 9.1 Planting Strip (PS) Sidewalk (SW) a. Major Road (each side) b. Minor Road

1.0m 1.0m

1.0m 1.0m

1.0m 0.5m

1.0m 0.5m

NOTE: refer to supplemental rules and regulations to implement PD 963 (HLURB A.O. no. 2 series of 1994 (12 April) 9.2 Road Pavement Developed Area Under Developed Area a. Major Road b. Minor Road c. Motor Court d. Sidewalks e. Alley Concrete / Asphalt Concrete / Asphalt Concrete / Asphalt Concrete / Asphalt Concrete / Asphalt Concrete/Asphalt Concrete/Asphalt Asphalt Asphalt Aggregates Macadam Stone Macadam Stone Macadam Stone Aggregates Aggregates

+ Under Developed Areas- Characterized by the predominant absence of utility systems or networks, especially water supply, roads & power + Developed Areas- Characterized by the predominant presenve of utility systems or networks especially water supply, roads and power 10. WATER SUPPLY Developed Area Under Developed Area Mandatory connection to appropriate piblic water system or community system if available, or centralized water supply system. If public water supply system exists, mandatory connection. ( LEVEL III ) LEVEL II - 1 communal faucet or communal well per 25 Dwelling Unit NOTE: Each subdivision must have at least an operational deepwell and pump sets with sufficient capacity to provide ADO, provided a spare pump and motor set is reserved 10.1 Minimum Water Supply Requirements 150 liters per capita per day for household connection 150 LCPD for household connection 10.2 Fire Protection 11. DRAINAGE SYSTEM Provision for Fire Protection shall comply with the requirements of the National Fire Protection Code (PD 1185) Underground Underground for Major Roads lined open canal (for other Roads) + The drainage system must conform with the natural drainage pattern of the subdivision site, and shall drain into appropriate water bodies, public drainage system or natural outfalls. 43 LCPD Handpump

BP 220 SOCIALIZED HOUSING


(PS) (SW)

1.0m 0.5m

1.0m 0.5m

A.O. no. 2 series of 1994 (12 April) Developed Area Under Developed Area Concrete/Asphalt Macadam Srone Macadam Srone Aggregates Aggregates Macadam Stone Macadam Stone Macadam Stone Aggregates Aggregates

racterized by the predominant absence of

s, especially water supply, roads & power

zed by the predominant presenve of utility

ecially water supply, roads and power Developed Area Under Developed Area If public water supply system exists, mandatory connection. ( LEVEL III ) LEVEL II - 1 communal faucet or communal well per 25 Dwelling Unit

d pump sets with sufficient capacity to

150 LCPD for household connection

43 LCPD Handpump

National Fire Protection Code (PD 1185) Lined Open Canal (sides of open canal shall be lined with stone rip-rap) of the subdivision site, and shall drain

alls.

PARAMETER

PD 957 OPEN MARKET HOUSING

BP 220 ECONOMIC HOUSING

12. SEWAGE DISPOSAL SYSTEM 12.1 Septic Tank Individual septic Tank conforming to standard design of the Sanitation Code. 12.2 Connection to Community Sewer System Individual / Communal Septic Tank conforming to standard design of the Sanitation Code.

Whenever possible, connections shall be made to an approved public or community sewer system subject to the requirements and provisions of the Sanitation Code and other applicable rules and regulations with regards to materials and installation practices.

13. POWER SUPPLY Mandatory Individual household connections to Primary & Alternate sources of power of service is available in the locality.

Developed Areas Mandatory Individual household connection of services is available in the locality.

Installation practices, materials and fixtures used shall be in accordance with the provision of the Electrical Code and local utility company. 14. GARBAGE DISPOSAL Provide sanitary and efficient refuse collection and disposal system whether independently or in conjunction with the local government garbage collection and disposal services. 15. SHELTER COMPONENT a. Minimum Floor Area a.1 Single-Detached Shall conform with the National Building Code (PD 1096) and local Zoning Ordinance a.2 Duplex a.3 Rowhouse a.2 22 sq. meters a.3 22 sq. meters NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine floor if any. b. Mnimum Level of Completion b.1 Single-Detached b.1 Duplex b.3 Rowhouse b.1 Complete House b.2 Complete House b.3 Complete House b.1 Complete House b.2 Complete House b.3 Complete House NOTE: Minimum floor area shall be in one floor level exclusive of mezzanine floor if any. 16. SETBACKS / EASEMENTS a. FRONT b. SIDE c. REAR d. ABUTMENTS 3.0 meters 2.0 meters 2.0 meters 1.50 meters 2.0 meters 2.0 meters a.1 22 sq. meters

May be allowed per requirements of the National Building Code (PD 1096)

BP 220 SOCIALIZED HOUSING

Individual / Communal Septic Tank conforming to standard design of the Sanitation Code.

or community sewer system subject to the

e rules and regulations with regards to

Under Developed Areas Mandatory Individual household connection of services is available in the locality.

e with the provision of the Electrical Code

em whether independently or in conjunction

a.1 16 sq. meters

a.2 18 sq. meters a.3 18 sq. meters

l be in one floor level exclusive of mezzanine

b.1 Shell House b.2 Shell House b.3 Shell House

l be in one floor level exclusive of mezzanine

1.50 meters 2.0 meters 2.0 meters

l Building Code (PD 1096)

You might also like