Z-PC Line

Stand alone high performance modules Inputs for sensors (thermoprobes TC/RTD, load cell), analog and digital signals Single / Three-phase network analyzer Ethernet gateways and OPC drivers Radio transmission modules RS485 ModBUS RTU interface, up to 1200 mt IEC 613311 programming system High level protocol PPP, HTTP, SMTP, FTP, Ethernet, ModBUS TCP, IEC 870 Automatic data transmission (log, sms, e-mail) Multi-function control units (CPU, datalogger, web server, RTU)

ModBUS technology for distributed control and data acquisition


1

Z-PC line, open, configUraBle and Standard SYStem


Analogue Input and Output Digital Input
Isolated input for reed sensors, proximity, pnp, npn, contact, inputs with fast counters up to 32 bit and 10 KHz

SoftWare platform
Acquisition and control standard analog signals (voltage, current, ohm), power supply, transducers, resolution up to 15 bit + sign

ZNET3
HW, communication, data conguration Integrated automation and telecontrol functions

Digital Output
SPST relay output or MosFET, delay and fail safe programmable, front diagnostics

Connection System and power-supply


Suppor ts in nylon loaded PA6 with fiber glass at 30% Hot swapping Power-supply terminal /data line Mounting on guide-DIN 46277 in vertical position

Special Modules: temperature control, load cells, electric network analyzer


Direct input from RTD 2, 3 or 4 wires Thermocouples acquisition J, K, R, S, T, B, E, N Electrical measurements acquisition from net analyzer Load cell (strain gauge) acquisition

data recorder
Data acquisition and recording software

Modular CPU and multi-functions


PLC, Web Server, RTU, datalogger, Ethernet bridge ModBUS Master / Slave on RS232/RS485 RS232 interfaces (user free/programming) Ethernet Port 10Base T opened to supervision networks and remote connection RISC / MISC Microprocessor at 32/64 bit Memories: up to 32 MB RAM, 64 MB flash memory (data) Backup battery for retentive variables

Communication Interfaces
Radio modules with short range 100 kbps, 10 mW, 434-869 MHz RS232-USB/RS485 serial Conversion Modules

Regulators
Ethernet Fieldbus
Analogue: Z-PID, universal input, proportional, integral, derivative action settings Digital: Z-D-IO, module 6 DI, 2 DO, I/O slave or automatic functioning for pneumatic valves, motorized and alarms management

WEB EDITOR
Development environment html/java supervision pages

Serial Connection

Html/Java Web Client LAN-Ethernet / ModBUS TCP Architetture Client/Server e VPN OPC SCADA

System for GSM/GPRS, Communication DSL PSTN, WiLAN, UHF operator panels, identification Printer, systems

I/O expansion

PLC, regulators and field devices


ModBUS RTU Master/Slave Profibus DP (Slave) CanOPEN (Master)

Z-NET RTU
Telecontrol systems front end

ArcHitectUreS
Distributed system, supervisory and control integration
Max 32 I/O modules, 1.200 m without repeater

Data transmission and remote control system

OPC SERVER
Max 32 I/O modules, 1.200 m without repeater 434 / 869 MHz 100 kbps

Real-time Interexchange data software

RS232 RS232 / RS485 ModBUS RTU - RS485 RS232 / RS485 ModBUS RTU - RS485

iSagraf
Z-TWS

Z-TWS

PLC 61131 programming toolkit + SENECA libraries

GSM / GPRS / PSTN / XDSL

LAN / WAN / Internet Ethernet - ModBUS TCP Ethernet - ModBUS TCP

LAN / WAN / Internet

codeSYS
PLC 61131 programming toolkit

LEGEND
Fieldbus / Control networks Serial connections LAN / WAN

LEGENDA
Fieldbus / Control networks Serial connections LAN / WAN

Application areaS

DATA ACQUISITION

REMOTE CONTROL

BUILDINGS & INFRASTRUCTURES

AUTOMATIONS

via Germania, 34 35127 Padova - Italy - Ph +39 049 87.05.359 (.408) Fax +39 049 87.06.287 www.seneca.it info@seneca.it
Document subject to modifcations and revisions. Reproduction forbidden if not authorized.

You might also like