Q: You suspect that poor network performance in a vSphere environment that you support is being caused by an incorrect switch

configuration. You have implemented a centralized network configuration using Distributed vSwitches (version 5.1) throughout. What feature of these dvSwitches could you use to ascertain the cause of the problem? Choose one. A: Network Teaming Analysis Network Monitoring dvSwitches do not have any features that allow this. Network Health Check

Q: With the release of VMware vCloud Networking and Security 5.1, some vShield functionality has been integrated into the VMware vSphere 5.1platform. Which of the following vShield components are included in VMware vCloud Networking for Security Advanced edition but are not present in the Standard Edition? Choose one.

A: vShield App vShield Edge vShield Endpoint vShield Zones Q: You are working on a design where the customer has specified that network uplink failures that are caused by physical switch configuration errors must be detected by vSphere and trigger a virtual switch uplink failover. Which network policy must you configure to support this? Choose one. A: Beacon Probing Link Status Notify Switches Failover Order

Q: The ESXi hosts that you will be using in a new vSphere cluster will be configured with 2 x 10Gb Ethernet NICs. Which vSphere technologies must you select in order to ensure that you can allocate and control network bandwidth for the Management, IP Storage, vMotion, vSphere Replication and Virtual Machine networks that you need to implement? Choose two. A: Distributed Virtual Switches Network I/O Control Link Aggregation Control Flow control

Q: Your customer has a datacenter where each ESXi host can have only a limited number of physical uplinks. Under normal operation, each virtual network will have two uplinks, but there is not enough capacity to dedicate standby NICs to handle failures. You want to ensure that each virtual network will always use its own dedicated uplinks but that during NIC, link or physical switch failures the uplinks from other virtual networks can be used. Which specific Failover Policies allow you to manage which uplinks are used during and after failures? Choose two.

A: Network Failure Detection Notify Switches Failover Order Failback Q: You are designing a virtual network environment that will make use of PVLANS to create to create a DMZ. Your PVLAN design has a Primary PVLAN 100 that is promiscuous, a secondary promiscuous PVLAN 101, secondary isolated PVLANs 105 & 106 and secondary community PVLANs 125 &126. You have an application that must be deployed in the DMZ that requires two servers that must be able to communicate with each other but must be isolated from all other systems in the DMZ. Which PVLANs can be used for these VMs? Choose two. A: 101

105 106 125 126

Q: A customer would like to centralize the management of all network configurations for all hosts. Which VMware license type will they require, and which type of network switches will they be configuring? Choose one. A: VMware Enterprise Edition, and Distributed vSwitches VMware Enterprise Plus Edition, and Standard vSwitches VMware Enterprise Plus Edition, and Distributed vSwitches VMware Enterprise Edition, and Standard vSwitches

Q: You have developed a virtual network design that makes use of standard virtual switches with four uplinks teamed using Route based on IP hash. During testing you find that some virtual machine traffic is failing to reach its destination but this is not consistent. Which of the following items should you check to ensure that the environment is configured correctly for this type of load balancing? Choose two. A: Ensure that the physical ports on the switches are configured to use LACP Ensure that the physical ports on the switches are configured to use static Etherchannel Ensure that the physical uplinks are not connected to separate physical switches that are not stacked Ensure that the physical uplinks are all connected to a single physical switch

CD wrong
Q: Following some reconfiguration work on the virtual network configuration of your customers vSphere 5.1 hosts, network traffic has suddenly stopped for one segment of the network. Monitoring the physical switch shows that all packets of data from that segment are either being dropped or the router is responding with messages indicating TTLs have been exceeded. W hich of the following items are most likely to be the cause of this issue? Choose two. A: The port group name is incorrect The VLAN ID is wrong for that segment

The MTU is incorrect The Uplink (vmnic) has failed The Cable between the physical switch and physical uplink (vmnic) has failed and beacon packets are causing a broadcast storm

Q: You are tasked with configuring the network connections (virtual switches, physical uplinks and port groups) for multiple ESXi hosts. You could manually configure each host which would be timeconsuming and could potentially introduce errors. You elect to configure one host correctly and then extract these settings and apply them to the new hosts. Which vSphere 5.1 feature should you use to do this? Choose one. A: vSphere Host Profiles vSphere Management Assistant vSphere Host Templates VMware Tools

Q: There are two types of connections you can add to virtual switches virtual machine port groups and vmkernel ports. Which of the functions listed below require appropriately configured VMKernel ports? Choose three. A: Fault Tolerance Network IO Control vMotion IP Storage High Availability

Q: You are designing a vSphere environment that will have to support NAS Storage. The storage team has already physically connected the storage units to the network. What specific network feature must you specify for each host to ensure that the storage will be available for use? Choose one. A: Configure the virtual switch and vmkernel port to support Jumbo Frames Configure the MTU on the virtual switch to be 9000 bytes Install the vendors NAS/NFS vSphere plugin

Add a vmkernel port with an IP address that can access the NAS storage

Q: Your customer has a test vSphere environment with vCenter Foundation and three ESXi hosts running vSphere 5.1 Enterprise Edition. They have standardized on Cisco network equipment in their environment and have been trying to install a Cisco Nexus 1000V virtual Switch. They have tried to import the virtual switch appliance but this has failed. Why are they unable to install this appliance? Choose one.

A: Their ESXi Enterprise Edition license does not support Distributed Virtual Switches They need to acquire a Cisco virtual appliance license before importing the appliance They need to configure vCenter the Cisco vSwitch plugin before trying to import the appliance Their vCenter Foundation license does not support Distributed Virtual Switches

Q: A customer is experiencing poor network performance and you have identified that network uplink bandwidth is insufficient for the demand on their ESXi hosts. There are unused physical network adapters in each of your hosts and the physical switches support NIC teaming. You tell the customer that the unused adapters on each host should be configured as additional uplinks for the production standard vSwitch. Which of the following teaming policies are valid choices for the uplink NIC teaming policy for the vSwitch uplinks? Choose three. A: Route based on Originating Port ID Load-based teaming Route based on IP Hash Route based on Source MAC Hash Route based on PVLAN ID

Q: Your customer is concerned that their dvSwitch configuration is very complex and they are concerned that in a disaster recovery situation they have to manually reconstruct their dvSwitch configurations. Which of the following procedures should you advise your customer to follow to ensure they can recover from a corrupted dvSwitch configuration? Choose one.

A: They should use a Third Party backup solution to back up their ESXi host network configuration They can back up the configuration of each Distributed Virtual Switch from within the Distributed Virtual Switch itself They must ensure that all configuration settings are fully documented They can use the VMware Data Protection Appliance to back up their ESXi host configurations, including the distributed vSwitches They can access the ESXi console and backup the network settings from there

Q: You have been monitoring network traffic statistics from a number of virtual machines in a customers environment. You find that for some VMs, the network statistics are reset if the VM is vMotion-migrated to a different host, but this does not happen to all VMs. Why are these statistics reset for some VMs and not for others? Choose two. A: Since all information pertaining to distributed ports is stored by vCenter in the vCenter database, the distributed virtual port statistics for VMs connected to a distributed vSwitch are retained when a VM is migrated Since all information pertaining to standard ports is stored by vCenter in the vCenter DB, the virtual port statistics for VMs connected to a standard vSwitch are retained when a VM is migrated Since all information pertaining to standard ports is stored by the ESXi host, the virtual port statistics for VMs connected to a standard vSwitch are reset when a VM is migrated Since all information pertaining to distributed ports is stored by the ESXi host, the virtual port statistics for VMs connected to a distributed vSwitch are reset when a VM is migrated

Q: You have implemented Distributed vSwitches (DVS) for all virtual networking in a customers virtual environment. What will happen if vCenter becomes unavailable? Choose one. A: All network configurations would immediately be lost and all network activity would stop vCenter should be protected with VMware Fault Tolerance if you are using distributed vSwitches Network activity will stop for a few minutes but HA will restart vCenter and everything will return to normal Virtual Machine and VMKernel network traffic works normally but you cannot manage or reconfigure the dvSwitch(es) until vCenter is recovered vSphere automatically migrates all virtual machines over to Standard vSwitches and everything continues to work as normal with no downtime.

Q: You are working on a virtual network and realize that network uplink bandwidth utilization is very high and key systems are being impacted. You wish to ensure that no single process can use all of the available bandwidth. Which networking feature of Network I/O Control (NIOC) would you configure to ensure this? Choose one. A:

Isolation Limits Reservations Shares

http://wenku.baidu.com/view/0f40876cc850ad02df804102.html

Your customer has two datacenters in their campus on separate layer 3 networks. They have excess capacity in the vSphere environment in one of the datacenters and are approaching the capacity limits in the other. They want to investigate the use of VXLANs to allow them to configure their environment so that they can move virtual machines between the two datacenters without reconfiguring them. Which of the following are pre-requisites that they must ensure are met in order to be able to implement VXLANs? Choose three.

A: A multicast range and segment ID pool must be assigned vShield Endpoint must be installed in both datacenters DHCP must be available on all VXLAN transport VLANs vCenter server must be at v5.1 or later All hosts must be at ESXi v5.0 or later

Q: You have just carried out a migration of a physical server to a virtual machine. The server hosts an application which used the MAC address of the original physical server network adapter as part of the application licensing parameters. The application will not start after the migration reporting an error with its license key. What should you advise your customer to do to resolve this?: Choose one. A: Obtain a new license key from the Application supplier (or agent) using the MAC address of the virtual NIC in the new application server VM Obtain a new license key from the Application supplier (or agent) using the MAC address of any physical NIC used for VM traffic in the ESXi host Remove the original network adapter from the old physical server and install it in your ESXi Host as an uplink NIC for vSwitch used by the VM Upgrade to Enterprise Licenses for the ESXi hosts in order to enable MAC address spoofing on the vSwitch used by the application VM

Q:

You have been tasked with updating the virtual networking design for a growing virtual infrastructure. You are restricted to a fixed set of IP addresses and, while you are successfully using subnets and VLANs to segregate traffic today, these will not be sufficient to handle the expected growth. Which two VMware technologies should you consider in order to help deal with the expected growth? Choose two. A: PVLAN NIOC VXLAN LACP

Q: Network security is a major concern for your customer, and you have to ensure your design will adequately protect confidential data from within your network and be able to meet the regulatory compliance requirements of your customers business. Which VMware security management product would be best suited for this task? Choose one. A: VMware Platform Security vShield App vShield Endpoint vShield Edge

Q: Virtual Machines connected to the same port group allow internal network communication. Virtual machines on different port groups cannot communicate internally, they have to access the physical network and be re-routed. True or False? Choose the correct answer: A: True Port groups do not allow bridging or routing internally False You can allow internal network communication, but you must enable this feature at the switch policy level