PSS240/24/10

10A,240W Single Phase Din Rail Mountable Switching Power Supplies -Full Range Input selection from 90 - 264 VAC Auto select -Typical efficiency of 89% -Compact design with a width of only 83.5mm -Parallel function available (Switch) -Two years product warranty

GENERAL SPECIFICATION Altitude During Operation (IEC 60068-2-13) Ambient Temperature Range (Operational at Vi norm) Ambient Temperature Range (Storage) Cooling Derating from +61C to +71C (see derating curve) Dimension Isolation Resistance (Input-Output @500VDC) Min. Isolation Voltage -AC (Input-FG) Min. Isolation Voltage -AC (Input-Output) Min. Isolation Voltage -DC (Input-FG) Min. Isolation Voltage -DC (Input-Output) MTBF (Bellcore Issue 6 @40C, GB) Pollution Degree Relative Humidity Range Switching Frequency (typ.) Temperature Coefficient Range 4850 m IMAGES

ACCESSORIES.... CAT. NO. DESCRIPTION STD. PACK

-40 to +71 deg.C -40 to +85 deg.C Free Air Convection 2.5%/ C Screw terminal type L124.5 X W83.5 X D123.6 mm 100 M 1500 VAC 3000 VAC 2121 VDC 4242 VDC 423000 hr 2 20 to 95 %RH 40 KHz +/- 0.03 % per deg. C CAT. NO. CCC CE Standard Used for Testing DESCRIPTION GB4943, GB9254, GB17625.1 EN 61000-6-3, EN 55022 Class B, EN 610003-2, EN 61000-3-3 E N 61000-6-2,EN 55024, EN 61000-4-2 Level 4, EN 61000-4-3 Level 3 EN 61000-4-4 Level 4, EN 61000-4-5 L-N Level 3, L / N-FG Level 4 EN 61000-4-6 Level 3, EN 61000-4-8 meet IEC 60068-2-27 (15G, 11ms, 3 Axis, 6 Faces, 3 times for each Face) EN 60950-1, CB scheme , EN 61558-1, EN 61558-2-17 (meet EN 60204) UL 508 Listed UL 60950-1, UL 1310 Class 2 Power (24V/E Models only) Recognized ISA 12.12.01 (Class I,Division 2,Groups A,B,C,and D) meet IEC 60068-2-6 (Mounting by rail : 10500 Hz, 2G, along X, Y, Z each Axis, 60 min for each Axis ) CONTROL AND PROTECTION SPECIFICATIONS Degree of protection Input fuse Internal surge voltage protection: IEC61000-45 Output short circuit Over voltage protection Power Ready Rated over load protection IP20 T6.3A / 250VAC internal Varistor Fold Forward 125 to 140 % Threshold voltage of contact closed(at start up) 17.6-19.4 VDC Electrical isolation 500VDC Contact rating at 60VDC,0.3A 120 to 145 % INPUT SPECIFICATIONS DC Input Voltage Range Input Phase Input Voltage Range (115VAC Selected) Input Voltage Range (230VAC Selected) Leakage Current (Input-FG) Leakage Current (Input-Output) Line Frequency-Max. Line Frequency-Min. Max. Inrush Current (Vi: 115 VAC) Max. Inrush Current (Vi: 230 VAC) P.F.C. (Passive) Power Dissipation (Vi: 230 VAC, Io norm) 50 50 50 Rated Input Current -Max. (Vi : 115 VAC) Rated Input Current -Max. (Vi : 230 VAC) Rated Input Current -Typ. (Vi : 115 VAC) Rated Input Current -Typ. (Vi : 230 VAC) Rated Max. Input Voltage Rated Min. Input Voltage 210 to 375 Single 90 to 132 VAC 180 to 264 VAC 3.5 mA 0.25 mA 63 Hz 47 Hz 30 A 60 A 0.7 typ. 35 W 5.4 A 2.2 A 4.0 A 1.55 A 240 VAC 100 VAC OUTPUT SPECIFICATIONS Capacitor Load 7000 F CA702 End Clamp in Polyamide 66 suitable for Din 32 / Din 35 / Din 35-15 Rails 50 CA202 End Clamp in Polyamide suitable for Din 35 / Din 35-15 Rails 50

ORDERING INFORMATION Output Voltage Output Current Output Wattage Input Voltage Range Efficiency (min.) Efficiency (typ.) Standard Packing Qnty Cat. No. 24 VDC 10 A 240 W 90-264 VAC 87% 89% 1 PSS240/24/10 PHYSICAL SPECIFICATIONS Case Material Dimensions (H x W x D) Packing Weight Metal 124.5 X 83.5 X 123.6 mm 1.5kg ; 16 pcs / 25 kg / 2.01 CUFT 1380g APPROVALS Vibration Resistance UL/cUL Shock Resistance TUV

ACCESSORIES IMAGES CAT. NO. CA501-1M CA501-1M-S CA501-2M CA501-2M-S CA701-1M CA701-2M CA701-2M-S CA701-1M-S CA701-15-1M CA701-15-1M-S CA701-15-2M CA701-15-2M-S DESCRIPTION Din 32 Rail unslotted 1 meter Din 32 Rail slotted 1 meter Din 32 Rail unslotted 2 meter Din 32 Rail slotted 2 meter Din 35 Rail unslotted 1 meter Din 35 Rail unslotted 2 meter Din 35 Rail slotted 2 meter Din 35 Rail slotted 1 meter Din 35 Rail 15 deep unslotted 1 meter Din 35 Rail 15 deep slotted 1 meter Din 35 Rail 15 deep unslotted 2 meter Din 35 Rail 15 deep slotted 2 meter STD. PACK 50 50 50 50 50 50 50 50 50

Connectwell Industries Pvt. Ltd. D7, Phase 2, MIDC, Dombivli (E), Maharashtra, India - 421204. Tel : +91 251 3980 600 / +91 251 3980 800 Fax : +91 251 3980 700 Email : connect@connectwell.com Website : www.connectwell.com b

OUTPUT SPECIFICATIONS....
DC LOW Indicator Threshold after start up (Red LED) DC ON Indicator Threshold at start up (Green LED) Efficiency Fall Time Hold Up Time ( Vi: 115VAC) Hold Up Time ( Vi: 230VAC) Line Regulation Load Regulation: Parallel Mode Load Regulation: Single Mode Minimum Load Output Current Output Voltage Output Voltage Accuracy (Adjusted before shipment) Output Voltage Trim Range Parallel Operation Power Back Immunity Rated Continuous Loading

CURRENT LIMITED CURVE

17.6 to 19.4 VDC 17.6 to 19.4 VDC 90% 150 msec 25 msec 30 msec +/- 0.5 % +/- 5 % +/- 1 % 0% 10 A 24 VDC 0 to +1 % 22.5 to 28.5 VDC 3 unit 35 VDC 10A @24Vdc / 8.4A @28.5Vdc 100 mV 150 ms 500 ms 2 ms 1000 ms 1500 msec EFFICIENCY CURVE

Rise Time Rise Time With 7000 F Transient Recovery Time Turn On Time Turn On Time With 7000 F

ORDERING INFORMATION PIN NO POSITION OTHER OTHER OTHER OTHER DESIGNATION DC LO DC ON S/P Vout ADJ. DESCRIPTION DC LOW voltage indicator LED Operation indicator LED Single / Parallel select switch Trimmerpotentiometer for Vout adjustment A normal open relaycontact for DC ON level control (never connect except 24V/E model) V+ VGround Positive output terminal Negative output terminal Ground this terminal to minimize high frequency emmissions Input terminals (phase conductor,no polarity at DC input) Input terminals (neutral conductor,no polarity at DC input) DERATING CURVE

OUT

RDY

OUT

3,4 5,6 7

OUT OUT IN

INSTALLATION DETAILS Cooling Normal convection.All sides 25mm free space.For cooling recommened connector size range screw terminal : AWG24-10 (0.2-4 sq.mm) flexible/solid cable-Input connector can withstand torque at max.9 pound-inches -Output connector can withstand torque at max.5.5 pound inches 8m/m stripping at cable end recommends. CONNECTION DETAILS Screw terminal: AWG24-10 (0.2~4mm ) flexible / solid cable, - Input connector can withstand torque at maximum 9 pound-inches. - Output connector can withstand torque at maximum 5.5 pound-inches. 8 m/m stripping at cable end recommends