INDUSTRIAL

H E AT P U M P S

Product range
March 2013

TABLE OF CONTENTS
Heat pump system benefits.....................................................................................................................6 Is the heat pump considered as a "RENEWABLE SOURCE" ?..............................................................8 ENERGETIC advantage of the heat pump...........................................................................................10 ECONOMIC advantage of the heat pump............................................................................................12 AIR - WATER heat pumps....................................................................................................................14 WATER - WATER heat pumps.............................................................................................................16 The heat pump INTEGRATED inside the plant....................................................................................18 Product range..........................................................................................................................................4

NOTE

> Technical datasheets


> General features..............................................................................22 > AIR-WATER heat pumps
HXP HT , HMP HT , HGA HT , HGP HT .........................................................................34 HSP , HXP , HMP , HGA , HGP .....................................................................................50 KSR , KXR ......................................................................................................................70 HXA ................................................................................................................................78

> WATER-WATER and BRINE-WATER heat pumps

HMW HT , HGW HT .......................................................................................................82 HSW , HXW , HMW , HGW ............................................................................................94 HSW LT , HXW LT , HMW LT .....................................................................................118

> Storage tanks

HT - P , HT - P 300 , HT - P 500 ..................................................................................136 HT - D 300 , HT - D 500 ...............................................................................................142 HT - M ..........................................................................................................................146

> Storage tanks for DOMESTIC HOT WATER with heat pump

HT-1..............................................................................................................................148

10
HXP HT

20
9 - 25

65

AIR - WATER

.0

Outdoor or indoor installation

MAXIMUM OUTLET WATER TEMPERATURE [C]

HSP
AIR - WATER Outdoor or indoor installation

4 - 11

HXP
AIR - WATER Outdoor or indoor installation

11 - 21

KSR
AIR - WATER Split installation

3-9

KXR
AIR - WATER Split installation

10 - 20

HSW
WATER - WATER Indoor installation

3 - 11

HXW
WATER - WATER Indoor installation

HSW LT
WATER - WATER Outdoor or indoor installation

3 - 11

HXW LT
WATER - WATER Outdoor or indoor installation

HXA

5 - 18

55
4

.0

AIR - WATER Outdoor installation

NOMINAL HEATING CAPACITY [kW]

30
HMP HT
AIR - WATER Outdoor or indoor installation

50
30 - 50

100
HGP HT
AIR - WATER Indoor installation

60 - 100

HGA HT
AIR - WATER Outdoor installation

60 - 100

HMW HT
WATER - WATER Indoor installation

30 - 60

HGW HT
WATER - WATER Indoor installation

70 - 120

HMP
AIR - WATER Outdoor or indoor installation

24 - 45

HGP
AIR - WATER Indoor installation

45 - 95

HGA
AIR - WATER Outdoor installation

45 - 95

12 - 27

HMW
WATER - WATER Indoor installation

30 - 55

HGW
WATER - WATER Indoor installation

55 - 110

12 - 27

HMW LT
WATER - WATER Outdoor or indoor installation

30 - 55

in the environment as renewable and > A new strategy inhexaustible energy for heating and source comfort

HEAT PUMP Satisfy the room SYSTEM comfort needs using BENEFITS the heat available

The air, the water and the ground, the three most common elements on Earth, represent a virtually inhexaustible source of energy and heat, that the modern technology applied to heat pumps allow to be used in an optimized way in order to satisfy the heating and cooling needs of all the dwellings with efficient and ecological solutions.

renewable source

energy efficiency

Heat pumps allow to get much higher efficiency levels compared to the traditional heating systems because they draw the main part of the required energy directly from the environment. The continuos improvement of the technologies applied to all the components and the constant optimization of the thermodynamic cycle, upon which the heat pump operating mode is based, allow to achieve always better performances.

The high energetic efficiency guaranteed by the heat pump and the advanced control system able to assure the maximum synergy between all the components of the plant allow to optimize the overall efficiency of the system during the whole year and to minimize the operating costs. The energy required to guarantee the room comfort is always produced in the most efficient way avoiding waste and taking advantage of the most convenient source both on the energetic and on the economical point of view.

operating costs reduction

domestic hot water production

Heat pumps can satisfy also the domestic hot water production needs coordinating the different requests by means of an accurate priority management. A proper water storage tank is always required in order to guarantee the maximum comfort in all the possible situations.

The heat pumps are equipped with a control system that allow the management of the whole plant to coordinate all the available heating sources (heat pump, thermal solar, boiler, stove) in order to satisfy in the best way the room comfort needs using the less quantity of energy as possible, produced in the most efficient way.

control and integration: the future is the system

cooling function

The heat pump can also be used to produce cold water to be used in the cooling plant. The thermodynamic cycle inversion allow to reverse the normal heat flux that, instead of flowing from the outdoor environment to the plant, flows from the plant to the outdoor environment. The possibility to use the heat pump also for cooling extends the operating period also to the summertime making the heat pump a complete solution for the residential heating and cooling needs and exalting the advantages of the heat pump system in terms of efficiency, overall dimensions and integrated control.

IS THE HEAT PUMP CONSIDERED AS A "RENEWABLE SOURCE"?

The temperature level of all this energy does not allow its direct use in order to satisfy the > The outdoor heating requests environment (air, water and ground) contains a huge quantity of completely renewable thermal energy
AIR

SUN

WATER

GROUND

SOURCE

HEAT PUMP

PLANT

The heat pump is able to increase the temperature level of such energy and to transfer it to the plant by means of a thermodynamic cycle. In order to perform such operation an amount of electrical energy (normally not renewable) is required. Also this energy is transformed in heat and released to the plant. Therefore not all the thermal energy supplied by the heat pump can be considered as renewable but only the portion taken from the outdoor environment. The heat pump could become a completely renewable source if also the electrical energy used to operate the thermodynamic cycle would come from a renewable source (i.e. photovoltaic, wind, hydroelectric)

In order to quantify the renewable energy (Qren) produced by a heat pump is necessary to consider its seasonal performance factor (SPF) that represents the ratio between the useful energy (Qc) available during the heating period and the electrical energy (L) required for the heat pump operation.

SPF =

Qc L

The portion of energy that comes from renewable source, given by the difference between the total thermal energy available for the plant and the electrical energy used, is therefore as bigger as higher is the heat pump efficiency.

Qren = Qc - L = Qc . (1-

1 SPF

The seasonal efciency of the modern heat pumps usually guarantees a renewable energy percentage variable from 75% to 100% of the total thermal energy supplied.

Q ren

QC

ENERGETIC ADVANTAGE
92

PRIMARY ENERGY

-30%

66

> The heat pump require ELECTRICAL ENERGY to work. In order to make a comparison with a traditional heating system that uses fossil fuel to work is necessary to consider the PRIMARY ENERGY consumption.

92
ELECTRICAL ENERGY

= 46%

92

30

= 109%

BOILER

HEAT PUMP

COP = 3,30

100

100

THE PRIMARY ENERGY SAVING AND THE CORRESPONDING POLLUTANT EMISSIONS CUT IS ABOUT

30%

10

For the same amount of thermal energy supplied to the plant, the quantity of primary energy required with a traditional heating system depends only on the efficiency of the generator. Considering as a traditional heating system a CONDENSING BOILER with an efficiency equal to 109%, to produce 100 thermal units, 92 primary energy units are required. In the case of a HEAT PUMP the quantity of primary energy required depends on the heat pump efficiency (COP) and on the conversion efficiency of the primary energy into electrical energy. Considering a conversion efficiency equal to 46% and a COP equal to 3,3 , to produce 100 thermal units, 30 electrical energy units are required, corresponding to 66 primary energy units.

PRIMARY ENERGY

92

92

92
ELECTRICAL ENERGY

= 46%

92

42

Considering a conversion efficiency equal to 46%, the heat pump system achieves a total efficiency, evaluated in terms of primary energy, higher than the one of a traditional heating system if the COP is higher than 2,36. The modern heat pumps, if properly designed and installed, normally achieve a seasonal efficiency higher than such value and suitable to guarantee always the energetic advantage of the heat pump system over the traditional heating systems.

When is the advantage guaranteed?

= 109%

BOILER

COP = 2,36

HEAT PUMP

100

100

GUARANTEED ADVANTAGE WHEN

COP > 2,36

11

ECONOMIC ADVANTAGE
The three main factors to be taken into account are: > the electrical energy cost > the fossil fuel cost > the heat pump seasonal efficiency

Though the energetic advantage of the heat pump system over a traditional heating system is easily demonstrated, the economic advantage is affected by a much higher number of factors and particularly by the ratio between the electrical energy cost and the fossil fuel cost.

When is the advantage guaranteed?

When the cost of the electrical energy and of the fossil fuel are known, is easy to calculate which is the minimum seasonal efficiency that the heat pump has to guarantee in order to be the best solution also from an economic point of view. Unlike a traditional heating system where the variability range of the generator efficiency is narrow, the heat pump systems can achieve seasonal efficiency levels very different according to: > TYPE OF THERMAL SOURCE > TYPE OF DISTRIBUTION PLANT

12

type of THERMAL SOURCE

The thermal source is the natural element from which the heat pump takes the thermal energy that is transferred to the plant, once its temperature level has been increased. Heat pumps can be classified into two main groups:

AIR-WATER
heat pumps
use the outdoor air as source

WATER-WATER
heat pumps
use the water as source (from well, river, lake or flowing inside geothermal probes)

type of DISTRIBUTION PLANT


60-70C
RADIATOR

The type of distribution plant strongly defines the temperature level at which the water inside the heat pump has to be heated. The lower the temperature of the water the higher is the efficiency of the heat pump.

40-50C

FAN COIL

RADIANT PLANT

25-35C

EFFICIENCY

13

AIR - WATER HEAT PUMPS

Outdoor air, often underestimated as thermal source, represents a very interesting solution, even in very cold and wet countries. The technology evolution has lead air-water heat pumps to be not only reliable but also convenient thanks to their simple installation and to their lower investment cost compared to water-water heat pumps.

outdoor installation

The simplest solution to use the energy contained in the outdoor air is to install the heat pump directly outdoor. It is necessary to reserve enough space around the heat pump to guarantee a proper air circulation and to prevent the freezing risk of the pipes that connect the heat pump to the plant using brine solutions or undergrounding completely the pipes.

> Type of installation

> Performances
Heating capacity [kW]

bivalent operating mode

-25

-23

-19

-15

-11

-7

-3

11

15

Outdoor air temperature [C]

The heating capacity supplied by the heat pump decreases when the outdoor air temperature decreases (at -15C the heating capacity is about the half compard to the corresponding capacity at 7C). To satisfy the heating requests of the building, that increases when the utdoor air temperature decreases due to the higher thermal losses, without applying an uneconomic heat pump oversizing, is necessary to integrate the heating power supplied by the heat pump with

14

The heat pump, installed in a technical room inside the building, aspires and ejects the outdoor air through properly designed ducts. The advantages, besides the lack of an outdoor place dedicated to the heat pump and the corresponding aesthetic impact, are the outdoor noise emissions reduction, the possibility to perform all the maintenance operations in a technical room repaired from bad weather, the thermal losses reduction due to the outdoor pipes and the water pipes freezing risk elimination. The heat pump efficiency is slightly penalized compared to the outdoor installation due to the higher electrical energy quantity required for the air circulation through the ducts. This kind of installation allows to use the exhaust air to heat, with a recuperator, the air at the heat pump inlet in order to increase its efficiency.

indoor installation

split installation

The heat pump is made of two units: one installed outdoor (extracts the heat from the air) and one installed indoor (transfers the heat to the plant). The two units are connected by means of refrigerant pipes, not affected by freezing risks, to be realized minimizing their lenght in order not to penalize the heat pump efficiency. Two solutions for this kind of installation are possible: COMPRESSOR CONTAINED IN THE OUTDOOR UNIT: the required place inside the building is very little as well as the indoor noise level is very low. COMPRESSOR CONTAINED IN THE INDOOR UNIT: the required place outside the building is very little as well as the outdoor noise level is very low and is possible to perform the maintenance operations in a technical room repaired from bad weather.

an auxiliary heating source (boiler, stove, electrical heaters) performing a bivalent operating mode. Below a defined outdoor air temperature value the heat pump, in order to satisfy properly the plant requests, is integrated or replaced by an auxiliary heating source that, in well designed plants, covers only the peaks and does not significantly penalize the system seasonal efficiency.

defrosting cycles

When the outdoor air temperature is low, the humidity contained in the air tends to deposit on the surface of the finned coil of the heat pump producing a thin ice layer that reduces the thermal exchange capability and therefore the performances. Periodically the proper operating mode of the heat pump is automatically restored by means of a defrosting cycle that, in order not to penalize the heat pump efficiency, has to be minimized in terms of lenght and frequency.

15

WATER - WATER Type of sources HEAT PUMPS


> GROUND Closed loop (geothermal)

Water and ground, thanks to their high thermal capacity, mantain during the whole year a very steady temperature at an average value higher than the one of the outdoor air allowing the water-water heat pumps to achieve absolutely the best efciencies. Moreover the stability of the performances of the waterwater heat pumps, due to source stability, allows to satisfy completely the plant needs without the necessity of an auxiliary heating source (monovalent operating mode). Though the plant realization is more complex and expensive compared to the air-water heat pumps, the water-water heat pumps have very small dimensions and very low noise levels that allow to be easily installed inside the building. Furthermore the absence of water pipes outdoor eliminates the freezing risk and reduces the thermal losses.

The ground represents a huge energy reserve steadily regenerated through the sun and the rain. At depths higher than 15 meters the temperature is pratically constant during the whole year and nearly equal to the annual average outdoor air temperature. The energy extraction from the ground is realized by means of geothermal probes made of pipes buried in the ground with a brine solution that flows inside them. Different types of probes are available but the most common are the vertical and the horizontal ones.

Temperature [C]

The design of the geothermal probes has to guarantee a proper heat exchange between the ground and the brine solution that flows inside them in order not to penalize the heat pump efficiency and capacity. The ground has to have the possibility to regenerate itself. A too intensive installation fo the geothermal probes can produce a gradual lowering of the ground temperature that after few years would penalize the system performances. The possibility to use the heat pump also for cooling facilitates the ground regeneration bringing it back, during summer time, at the starting temperature level.

16

Depth [m]

They are realized with pipes vertically inserted in the ground up to a depth of about 100 meters. They allow to taking better advantage of the ground temperature steadiness and they need a small surface. Their realization is however expensive and often bounded to the local regulations in force for groundwater respect.

vertical probes horizontal probes

They are realized with pipes horizontally distributed on the ground at a depth of about 2 meters. They are simple and cheap to be realized but they require a large surface free from asphalt and trees and they are much more influenced by the ground temperature oscillations.

VERTICAL PROBES

HORIZONTAL PROBES

> WATER Open loop


The heat pump extracts the energy directly from the water taken from wells, rivers, lakes The water enters directly in the heat pump and is then released in the environment. The absence of intermediate heat exchanges allows to optimize the system efficiency. On the other hand it is necessary to pay attention not to pollute the used water and not to modify too much the temperature respecting the local regulations in force, often very restrictive

groundwater

The surface water should be preferred to reduce the energy required to the source side pump operation.

surface water

It guarantees a higher temperature steadiness but requires a higher power input for the water extraction. Moreover it is necessary to realize two independent wells, one for extraction and one for admission, respecting the local regulations in force. In any case it is recommended to verify the quality and the cleaning of the water in order to avoid the heat pump heat exchanger fouling and corrosion. The presence of intermediate heat exchangers, required not to send the source water directly in the heat pump heat exchanger, must be considered in the system performances evaluation.

SURFACE WATER

GROUND WATER

17

Tank for the plant THE HEAT PUMP > when is it necessary? INTEGRATED INSIDE THE PLANT
The constant evolution of the different components that are involved in the plant is not enough in order to guarantee to obtain the best possible total performances Only the coordination between all the available heating sources and an integrated management of the distribution systems are able to guarantee to satisfy in every moment and in the best way the comfort needs using the minimum energy quantity as possible, generated in the most efcient way as possible. The heat pump controller is able to perform all these functions by means of advanced control algorithms and smart logics of activation and coordination of the plant components.

The tank for the plant is often considered as an expensive and large component that is necesssary to "protect" the heat pump. Indeed the heat pump works properly and in an absolutely safe way also without tank.

PLANT COMFORT GRAPH

SET POINT

Wide oscillations REDUCED COMFORT

SET POINT

Small oscillations HIGH COMFORT

When the heat pump is connected to distribution plant with a low water content (i.e. radiator plants or fan coil plants) the temperature oscillations of the water sent to the hydronic terminals can become very wide causing not comfortable situations in the ambient. In order to restrict the temperature oscillations it is necessary to increase the thermal inertia of the plant increasing the available water volume so as to slowing down the temperature variations and allow the system to dynamically adapt to plant needs keeping a high comfort level.

18

Besides the function of stabilize the water temperature in the plant, the tank has a lot of other functions that are highlighted in the modern plants, more and more advanced and complex. The tank thermal inertia allow to stabilize the water temperature in the plant in order to guarantee a constant ambient temperature (perceived by the user as comfortable). In plant equipped with AIR-WATER heat pumps the tank allows NOT to send cold water to the hydronic terminals during the defrosting cycles. The tank is the connection point between the different heating sources (heat pump, solar panel, boiler, stove) and the distribution circuits (radiant circuits, fan coil circuits, radiator circuits). The heating requests coming from the building are converted, by means of climatic curves optimized for each circuit, into a single set point for the tank that dynamically changes to be always optimized to guarantee the best efficiency. The tank temperature becomes a fundamental index to carry out the coordination logics of the available heating sources. The tank allows to produce thermal energy when is much more convenient and to use it when is requested by the plant. For example it is possible to take advantage of the time slots during which the electrical energy is cheaper or to use an overproduction coming from photovoltaic panels. The tank allows to reduce the heating request peaks and therefore to install smaller heat pumps with a corresponding reduction of the committed electrical power. The possibility to use the tank temperature to coordinate the available heating sources allows moreover to optimize the circulation pumps management activating them only when necessary. Without tank it would be necessary to maintain a water flow through the heat pump heat exchanger to control the return temperature and keep it close to the set point value.

the main functions of the tank for the plant

The tank allows to satisfy the heating needs with the thermal energy produced by other renewable sources like solar thermal or biomass since their availability and the plant needs not always occur at the same time. The tank represent a thermal energy storage that guarantees the plant to be in some extent autonomous also when the heat pump is used to satisfy other needs (for example in the domestic hot water production) or the electrical energy is not available. For example in many european countries electrical power supply contracts are available that can offer a lower energy cost if the user can accept the power supply to be interrupted up to 2 hours in a row. In such cases the tank is chosen according to this specific need.

19

> Domestic hot water Which are the differences with a traditional system
The domestic hot water production with a heat pump always requires a tank. The instantaneous domestic hot water production would require a too high absorbed electrical power for residential applications. Moreover with the heat pump is not possible to heat the water inside the tank up to temperatures higher than 50-55C (according to the kind of heat pump).

> Heating sources How to optimize their use?


To optimize the integration of different heating sources within the same plant is necessary to use in every moment the source that is able to satisfy the plant needs in the most efficient way, both on the energetic point of view and on the economic point of view. The heat pump controller allows to customize the control logic that enables the available sources modifying some activation thresholds according to the cost of the different energy sources and the features of the generators installed in the plant. Generally the most common logic according which the priority are assigned is realized by the activation in sequence of : > THERMAL SOLAR (both for domestic hot water production and for heating) > WATER-WATER heat pump > AIR-WATER heat pump > COMBUSTION generators (boiler, stove...) > ELECTRICAL HEATERS

The tank contains domestic hot water ready to be used that can be heated in two different ways. COIL The tank is heated by means of a coil inside which the hot water produced by the heat pump flows. The coil must be properly sized in order to be coupled with heat pumps (at least a surface of 0,5 m2 per heating power kW supplied by the heat pump are recommended). "PRIMARY" HEAT EXCHANGER The tank is heated by means of an external heat exchanger placed between the heat pump and the tank. The efficiency of the thermal exchange is higher than the one of the coil and allows to get higher temperatures inside the tank with the same water temperature produced by the heat pump. In both cases the disinfection legionella cycles, if necessary, must ne performed with the help of an auxiliary heating source (electrical heaters, boiler, solar...)

tank containing domestic hot water

The tank contains hot water to be used to produce instantaneously domestic hot water, just when it is requested, by means of an external "SECONDARY" HEAT EXCHANGER. The hot water contained inside the tank is not affected by the legionella problem.

tank containing "technical" water

20

>

TECHNICAL
datasheets
21

> OPERATING RANGE


AIR-WATER HEAT PUMPS


HEATING
75 70 65 60

DT

= 10 C

65

.0

Outlet temperature - plant side [C]

55 50 45 40 35 30 25 20 15 10 5 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55

55

.0

Inlet air temperature d.b. [C]

COOLING
45 40

Outlet temperature - plant side [C]

35 30 25 20 15 10 5 0 -5 -25 -20 -15 -10 -5 0 5 10 15 20 25

55

.0

65

.0

30

35

40

45

50

55

Inlet air temperature d.b. [C]

22

GENERAL FEATURES

WATER-WATER HEAT PUMPS


HEATING
75 70 65 60

DT

= 10 C

65

.0

Outlet temperature - plant side [C]

55 50 45 40 35 30 25 20 15 10 5 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55

Inlet temperature - source side [C]

COOLING
45 40

Outlet temperature - plant side [C]

35 30 25 20 15 10 5 0 -5 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40

65

.0

45

50

55

Inlet temperature - source side [C] The dotted lines show the operating area when brine solutions in the source side hydraulic circuit are used.

23

> PERFORMACES IN HEATING


AIR-WATER HEAT PUMPS
Heating capacity
1.6

65

.0

1.4

A B C

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal condition is :

1.2

A7W35 source : air in 7C d.b. 6C w.b. plant : water in 30C out 35C Outlet temperature plant side : A = 65C B = 55C C = 45C

1.0

D
0.8

0.6

D = 35C E = 25C

0.4 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Power input
2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30 2.2 2.0 1.8

COP

E D

1.6 1.4 1.2 1.0 0.8 0.6

C B A

0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Inlet air temperature w.b. [C]

24

GENERAL FEATURES

> PERFORMACES IN COOLING


AIR-WATER HEAT PUMPS
Cooling capacity
2.2

65

.0

2.0 1.8

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal condition is :

1.6 1.4

A35W7 source : air in 35C d.b. plant : water in 12C out 7C Outlet temperature plant side : A = 24C B = 18C

1.2 1.0

0.8 0.6

C = 12C D = 7C

0.4 0 5 10 15 20 25 30 35 40 45 50

Inlet air temperature d.b. [C]

Power input
2.2 2.2

EER

2.0 1.8

2.0 1.8

A B C D

1.6 1.4

1.6 1.4

B
1.2 1.0 1.2

A D C
0 5 10 15 20 25 30 35 40 45 50

1.0

0.8 0.6

0.8 0.6

0.4

0.4 0 5 10 15 20 25 30 35 40 45 50

Inlet air temperature d.b. [C]

Inlet air temperature d.b. [C]

25

> PERFORMACES IN HEATING


AIR-WATER HEAT PUMPS
Heating capacity
1.6

1.4

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions.

B
The reference nominal condition is :

1.2

C D

A7W35 source : air in 7C d.b. 6C w.b. plant : water in 30C out 35C Outlet temperature plant side : A = 65C B = 55C C = 45C

1.0

E
0.8

0.6

D = 35C E = 25C

0.4 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Power input
2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30 2.2 2.0 1.8

COP

E D

1.6 1.4 1.2 1.0 0.8 0.6

C B

0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Inlet air temperature w.b. [C]

26

GENERAL FEATURES

> PERFORMACES IN COOLING


AIR-WATER HEAT PUMPS
Cooling capacity The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal condition is : A35W7 source : air in 35C d.b. plant : water in 12C out 7C Outlet temperature plant side : A = 24C B = 18C

C = 12C D = 7C

Inlet air temperature d.b. [C]

Power input

EER

A B C D B A D C

Inlet air temperature d.b. [C]

Inlet air temperature d.b. [C]

27

> PERFORMACES IN HEATING


AIR-WATER HEAT PUMPS
Heating capacity
1.6

55

.0

1.4

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions.

B
The reference nominal condition is :

1.2

C D

A7W35 source : air in 7C d.b. 6C w.b. plant : water in 30C out 35C Outlet temperature plant side : A = 65C B = 55C C = 45C

1.0

E
0.8

0.6

D = 35C E = 25C

0.4 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Power input
2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30 2.2 2.0 1.8

COP

E D

1.6 1.4 1.2 1.0 0.8 0.6

C B

0.4 0.2 -20 -15 -10 -5 0 5 10 15 20 25 30

Inlet air temperature w.b. [C]

Inlet air temperature w.b. [C]

28

GENERAL FEATURES

> PERFORMACES IN COOLING


AIR-WATER HEAT PUMPS
Cooling capacity
2.2

55

.0

2.0 1.8

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal condition is :

1.6 1.4

A35W7 source : air in 35C d.b. plant : water in 12C out 7C Outlet temperature plant side : A = 24C B = 18C

1.2 1.0

0.8 0.6

C = 12C D = 7C

0.4 0 5 10 15 20 25 30 35 40 45 50

Inlet air temperature d.b. [C]

Power input
2.2 2.2

EER

2.0 1.8

2.0 1.8

A B C D

1.6 1.4

1.6 1.4

B
1.2 1.0 1.2

A D C
0 5 10 15 20 25 30 35 40 45 50

1.0

0.8 0.6

0.8 0.6

0.4

0.4 0 5 10 15 20 25 30 35 40 45 50

Inlet air temperature d.b. [C]

Inlet air temperature d.b. [C]

29

> PERFORMACES IN HEATING


WATER-WATER HEAT PUMPS
Heating capacity
2.2 2.2

65
A B C D E

.0

Heating capacity ( water )

2.0 1.8

1.6 1.4

2.0 1.8

1.6 1.4

1.2 1.0

1.2 1.0

0.8 0.6

0.8 0.6

0.4 -10 -5 0 5 10 15 20 25

0.4 -10 -5 0 5 10 15 20 25

Inlet temperature - source side [C] Power input ( brine and water )
2.2

Inlet temperature - source side [C] The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal conditions are : WATER-WATER units : W10W35 source : water in 10C out 7C plant : water in 30C out 35C BRINE-WATER units : B0W35 source : brine in 0C out -3C plant : water in 30C out 35C

2.0 1.8

1.6 1.4

1.2 1.0

0.8 0.6

Outlet temperature plant side :

A
-10 -5

B
0 5

C
10

D
15

E
20 25

A = 65C B = 55C C = 45C D = 35C E = 25C COP ( water )


3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4

0.4

Inlet temperature - source side [C] COP ( brine )


3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 -10 -5 0 5 10 15 20 25

-10

-5

10

15

20

25

Inlet temperature - source side [C]


30

Inlet temperature - source side [C]

GENERAL FEATURES

> PERFORMACES IN COOLING


WATER-WATER HEAT PUMPS
Cooling capacity ( brine and water )

65

.0

C D

The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal conditions are : WATER-WATER units : W30W7 source : water in 30C out 35C plant : water in 12C out 7C BRINE-WATER units : B30W7 source : brine in 30C out 35C plant : water in 12C out 7C Outlet temperature plant side : A = 24C B = 18C C = 12C D = 7C EER ( brine and water )

Inlet temperature - source side [C] Power input ( brine and water )

A B C D

C B

Inlet temperature - source side [C]

Inlet temperature - source side [C]

The performances of the units, when used as brine - water, are referred to applications in which the source side fluid is a solution of water and 30% ethylene glycol by volume. Such a concentration guarantees a freezing temperature of about -15C and allows the unit to work inside the declared operating limits.

31

> PERFORMACES IN HEATING


WATER-WATER HEAT PUMPS
Heating capacity Heating capacity ( water )

B D E C

B C D E
Inlet temperature - source side [C] Power input ( brine and water ) Inlet temperature - source side [C] The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal conditions are : WATER-WATER units : W10W35 source : water in 10C out 7C plant : water in 30C out 35C BRINE-WATER units : B0W35 source : brine in 0C out -3C plant : water in 30C out 35C Outlet temperature plant side :

A = 65C B = 55C C = 45C D = 35C E = 25C COP ( water )

Inlet temperature - source side [C] COP ( brine )

E D C B B C D

Inlet temperature - source side [C]


32

Inlet temperature - source side [C]

GENERAL FEATURES

> PERFORMACES IN COOLING


WATER-WATER HEAT PUMPS
Cooling capacity ( brine and water ) The graphs allow to get the corrective factors to be applied to the nominal performances in order to obtain the real performances in the selected operating conditions. The reference nominal conditions are : WATER-WATER units : W30W7 source : water in 30C out 35C plant : water in 12C out 7C BRINE-WATER units : B30W7 source : brine in 30C out 35C plant : water in 12C out 7C Outlet temperature plant side : A = 24C B = 18C C = 12C D = 7C EER ( brine and water )

C D

Inlet temperature - source side [C] Power input ( brine and water )

A B C D

C B

Inlet temperature - source side [C]

Inlet temperature - source side [C]

The performances of the units, when used as brine - water, are referred to applications in which the source side fluid is a solution of water and 30% ethylene glycol by volume. Such a concentration guarantees a freezing temperature of about -15C and allows the unit to work inside the declared operating limits.

33

> HXP HT
Available range
Unit type IP Reversible heat pump

AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION


E

-FRIEND
L

Y
RE F

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable both for outdoor or indoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching proCod. BTP00570
34

grams for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressor is equipped with vapour and liquid injection and is placed on an economized refrigerant circuit with plate heat exchanger and electronic expansion valve dedicated to the injection. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fan with electronic control of the rotational speed guarantees high efficiencies and low noise in all the operating conditions and allows to install the unit both outdoor (with protection caps) or indoor (with ducted air inlet and outlet). It is moreover possible to reduce the noise during the night. All the units with three-phase power supply are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

65

.0

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Adjustable rubber vibration dampers Protecion caps Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 02

Data: 24/01/2013

>

HXP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

9.1
3650 30

12.1
4150 30

15.1
4150 30

20.1
7150 50

25.1
7150 50 m3/h Pa

Cooling OPERATING LIMITS Unit type min max min

Heating max

Outdoor air inlet temperature IP 5 50 -22 42 C Water outlet temperature IP 6 25 30 65 * C * The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
35

> >

HXP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP A7W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 9.1


Heating capacity Power input 8,82 1,92

12.1
11,8 2,58

15.1
15,3 3,32

20.1
19,8 4,33

25.1
25,0 5,49 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,59
1524 14 7,45 1,92

4,57
2043 16 10,0 2,58

4,61
2632 24 12,8 3,32

4,57
3429 16 16,7 4,33

4,55
4312 24 21,1 5,48

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,88
1288 10 9,03 2,36

3,87
1727 12 12,1 3,16

3,86
2217 18 15,5 4,07

3,86
2892 11 20,2 5,31

3,85
3637 17 25,5 6,71

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,83
1560 14

3,83
2086 16

3,81
2690 25

3,80
3500 16

3,80
4414 25

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 9.1


Heating capacity Power input 8,93 2,45

12.1
11,9 3,30

15.1
15,4 4,24

20.1
20,1 5,53

25.1
25,3 7,01 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,64
1548 14 7,57 2,45

3,61
2068 16 10,1 3,30

3,63
2659 24 13,0 4,23

3,63
3476 16 17,0 5,54

3,61
4380 25 21,5 6,99

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,09
1314 11 6,86 2,18

3,06
1755 12 9,19 2,93

3,07
2259 18 11,9 3,76

3,07
2954 12 15,4 4,91

3,08
3719 18 19,4 6,20

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,15
1179 9

3,14
1581 10

3,16
2042 16

3,14
2643 10

3,13
3329 15

l/h kPa

IP A7W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB 9.1 12.1 15.1
Heating capacity Power input 9,28 3,76 12,4 5,06 16,0 6,47

20.1
20,9 8,49

25.1
26,3 10,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,47
812 5 7,96 3,77

2,45
1085 5 10,7 5,06

2,47
1400 8 13,7 6,48

2,46
1828 5 17,9 8,51

2,46
2301 7 22,5 10,7

l/h kPa kW kW

A2W65

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,11
696 4 9,08 3,02

2,11
936 4 12,2 4,05

2,11
1199 6 15,6 5,19

2,10
1566 4 20,4 6,80

2,10
1968 5 25,7 8,57

l/h kPa kW kW

A7W55

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,01
988 7 7,73 3,02

3,01
1329 8 10,4 4,07

3,01
1700 11 13,3 5,19

3,00
2223 7 17,4 6,82

3,00
2800 11 21,9 8,59

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,56
842 5

2,56
1133 6

2,56
1449 9

2,55
1896 5

2,55
2386 8

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
36

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HXP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS
25.1
V-ph-Hz n n

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

9.1

12.1
230 - 1 - 50 400 - 3N - 50

15.1

20.1
400 - 3N - 50

scroll with vapour injection (EVI) 1/1 stainless steel brazed plates finned coil plug fan 1 1 M 1 M 11/4 M 1 M

ACOUSTIC PERFORMANCES
Unit without accessory Protection caps
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

9.1
71 55 45 39

12.1
72 56 46 40

15.1
72 57 46 41

20.1
74 59 48 43

25.1
74 59 48 43 dB(A) dB(A) dB(A) dB(A)

Unit with accessory Protection caps


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

9.1
67 52 41 36

12.1
68 53 42 37

15.1
69 54 43 38

20.1
71 55 45 40

25.1
71 55 45 40 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. C D 600 mm 600 mm

Outdoor installation

9.1 - 12.1 - 15.1


A1 B1 B2 H 730 730 450 1470

20.1 - 25.1
880 880 465 1620 mm mm mm mm

Indoor installation
37

> HMP HT
Available range
Unit type IP Reversible heat pump

AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION


E

-FRIEND
L

Y
RE F

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable both for outdoor or indoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching proCod. BTP00572
38

grams for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressor is equipped with vapour and liquid injection and is placed on an economized refrigerant circuit with plate heat exchanger and electronic expansion valve dedicated to the injection. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fan with electronic control of the rotational speed guarantees high efficiencies and low noise in all the operating conditions and allows to install the unit both outdoor (with protection caps) or indoor (with ducted air inlet and outlet). It is moreover possible to reduce the noise during the night. All the units with three-phase power supply are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

65

.0

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Adjustable rubber vibration dampers Protecion caps Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 02

Data: 24/01/2013

>

HMP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

30.1
7850 50

35.1
7850 50

40.1
7850 50

45.1
11400 150

50.1
11400 150 m3/h Pa

Cooling OPERATING LIMITS Unit type min max min

Heating max

Outdoor air inlet temperature IP 5 50 -22 42 C Water outlet temperature IP 6 25 30 65 * C * The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
39

> >

HMP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP A7W35

NOMINAL performances - Radiant plants Base acoustic setting up (AB) 30.1


Heating capacity Power input 29,2 6,32

35.1
34,4 7,48

40.1
38,6 8,40

45.1
44,1 9,59

50.1
50,4 11,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,62
5039 21 24,7 6,32

4,60
5923 28 29,0 7,46

4,60
6650 35 32,6 8,36

4,60
7602 31 37,2 9,55

4,58
8676 40 42,5 11,0

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,91
4260 15 29,8 7,74

3,89
5005 21 35,0 9,15

3,90
5628 26 39,3 10,2

3,90
6425 22 44,9 11,7

3,86
7325 29 51,2 13,4

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,85
5155 22

3,83
6069 30

3,85
6811 37

3,84
7776 32

3,82
8880 42

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Base acoustic setting up (AB) 30.1


Heating capacity Power input 29,6 8,07

35.1
34,8 9,54

40.1
39,1 10,7

45.1
44,6 12,2

50.1
51,0 14,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,67
5127 22 25,1 8,06

3,65
6013 29 29,5 9,52

3,65
6761 36 33,1 10,6

3,66
7716 32 37,8 12,2

3,64
8811 41 43,2 14,0

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,11
4345 16 22,7 7,15

3,10
5109 21 26,6 8,42

3,12
5735 27 29,9 9,44

3,10
6552 23 34,1 10,8

3,09
7473 30 38,9 12,4

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,17
3896 13

3,16
4582 18

3,17
5148 22

3,16
5869 19

3,14
6710 25

l/h kPa

IP A7W65

NOMINAL performances - HIGH temperature plants Base acoustic setting up (AB) 30.1
Heating capacity Power input 30,7 12,3

35.1
36,1 14,5

40.1
40,5 16,2

45.1
46,3 18,6

50.1
53,0 21,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,50
2686 6 26,3 12,4

2,49
3158 9 31,0 14,5

2,50
3543 11 34,7 16,2

2,49
4051 9 39,7 18,6

2,49
4628 12 45,3 21,2

l/h kPa kW kW

A2W65

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,12
2301 5 30,0 9,89

2,14
2712 6 35,3 11,6

2,14
3036 8 39,7 13,1

2,13
3473 7 45,4 15,0

2,14
3963 9 51,7 17,1

l/h kPa kW kW

A7W55

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,03
3269 9 25,6 9,91

3,04
3846 12 30,1 11,6

3,03
4315 15 33,7 13,0

3,03
4936 14 38,6 14,9

3,02
5623 17 44,1 17,1

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,58
2789 7

2,59
3280 9

2,59
3672 11

2,59
4206 10

2,58
4794 13

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
40

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HMP HT

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS
50.1
V-ph-Hz n n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

30.1

35.1

40.1
400 - 3N - 50

45.1

scroll with vapour injection (EVI) 1/1 stainless steel brazed plates finned coil plug fan 1 11/4 M 1 M

ACOUSTIC PERFORMANCES
Unit without accessory Protection caps
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

30.1
76 60 50 44

35.1
77 61 51 45

40.1
77 61 51 45

45.1
78 62 52 46

50.1
78 62 52 46 dB(A) dB(A) dB(A) dB(A)

Unit with accessory Protection caps


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

30.1
72 56 46 41

35.1
73 57 47 42

40.1
73 57 47 42

45.1
74 58 48 43

50.1
74 58 48 43 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. C D 600 mm 600 mm

Outdoor installation

30.1 - 35.1 - 40.1


A1 B1 B2 H 1180 880 465 1620

45.1 - 50.1
1480 880 465 1620 mm mm mm mm

Indoor installation
41

> HGA HT
Available range
Unit type IP Reversible heat pump

AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION


E

-FRIEND
L

Y
RE F

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for outdoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
42

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with two scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, axial fans, finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. Both the compressors are equipped with vapour and liquid injection and are placed on an economized refrigerant circuit with plate heat exchanger and electronic expansion valve dedicated to the injection. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The axial fans, equipped with electronic control of the rotational speed, guarantee high efficiencies in all the operating conditions and the possibility to reduce the noise level during the night. All the units are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and indi-

E IG

RA N T

65

.0

vidually tested in the factory. Only electric and hydraulic connections are required for installation.

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Soft starter not present standard

Accessories
Rubber vibration dampers Coil protecion grilles Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Cod. BTP00623

Rev. 00

Data: 24/01/2013

>

HGA HT

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS Unit type min max min

Heating max

Outdoor air inlet temperature IP 5 50 -22 42 C Water outlet temperature IP 6 25 30 65 * C * The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
43

> >

HGA HT

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

IP A7W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 60.2


Heating capacity Power input 57,5 12,2

70.2
67,8 14,4

80.2
75,7 16,1

90.2
85,4 18,1

100.2
99,5 21,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,71
9923 22 48,5 12,2

4,71
11689 24 57,3 14,4

4,70
13058 24 63,9 16,1

4,72
14737 22 72,1 18,1

4,72
17179 21 84,0 21,1

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,98
8382 16 58,7 15,3

3,98
9888 18 69,1 18,1

3,97
11031 18 77,3 20,2

3,98
12451 16 87,1 22,7

3,98
14512 16 102 26,6

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,84
10156 23

3,82
11966 25

3,83
13380 25

3,84
15070 22

3,83
17587 22

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 60.2


Heating capacity Power input 58,2 15,6

70.2
68,6 18,4

80.2
76,6 20,5

90.2
86,4 23,1

100.2
101 27,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,73
10080 22 49,3 15,5

3,73
11870 24 58,2 18,3

3,74
13260 25 64,9 20,5

3,74
14963 22 73,3 23,1

3,74
17449 22 85,4 27,0

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,18
8551 17 44,6 14,1

3,18
10080 18 52,6 16,6

3,17
11244 18 58,7 18,6

3,17
12704 16 66,2 20,9

3,16
14807 16 77,2 24,5

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,16
7671 14

3,17
9044 15

3,16
10091 15

3,17
11378 14

3,15
13283 14

l/h kPa

IP A7W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 60.2 70.2 80.2
Heating capacity Power input 60,5 23,8 71,2 27,9 79,5 31,3

90.2
89,8 35,3

100.2
105 41,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,54
5293 7 51,8 23,8

2,55
6229 8 61,0 28,0

2,54
6955 8 68,2 31,4

2,54
7856 7 77,0 35,3

2,54
9160 7 89,7 41,3

l/h kPa kW kW

A2W65

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,18
4532 5 59,2 19,1

2,18
5337 6 69,7 22,5

2,17
5967 6 77,8 25,1

2,18
6736 5 87,8 28,3

2,17
7847 5 102 33,1

l/h kPa kW kW

A7W55

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,10
6440 10 50,3 19,1

3,10
7584 11 59,3 22,4

3,10
8466 11 66,3 25,2

3,10
9556 10 74,9 28,4

3,08
11147 10 87,3 33,2

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,63
5481 7

2,65
6462 8

2,63
7213 8

2,64
8150 7

2,63
9502 7

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
44

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HGA HT

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS


90.2 100.2
V-ph-Hz n 4 n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

60.2

70.2

80.2
400 - 3 - 50

scroll with vapour injection (EVI) 2/1 stainless steel brazed plates finned coil axial 2 3 2 M 1 1/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

60.2
79 61 52 47

70.2
80 62 53 48

80.2
80 62 53 48

90.2
81 62 54 49

100.2
81 62 54 49 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

60.2
76 58 49 44

70.2
77 59 50 45

80.2
77 59 50 45

90.2
78 59 51 46

100.2
78 59 51 46

The acoustic performances are referred to units operating in cooling mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA

Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

C D E

1200 mm 1000 mm 1000 mm

60.2
A B H 1130 1710 1980

70.2 - 80.2
1130 2430 1980

90.2 - 100.2
1130 3130 1980 mm mm mm
E
D

45

> HGP HT
Available range
Unit type IP Reversible heat pump

AIR - WATER HEAT PUMPS FOR INDOOR INSTALLATION


E

-FRIEND
L

Y
RE F

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for indoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
46

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with two scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fans (plug fans), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. Both the compressors are equipped with vapour and liquid injection and are placed on an economized refrigerant circuit with plate heat exchanger and electronic expansion valve dedicated to the injection. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fans with electronic control of the rotational speed guarantee high efficiencies and low noise in all the operating conditions and allow to install the unit indoor (with ducted air inlet and outlet). It is moreover possible to reduce the noise level during the night. All the units are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control.

E IG

RA N T

65

.0

All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Soft starter not present standard

Accessories
Rubber vibration dampers Coil protecion grilles Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Cod. BTP00627

Rev. 00

Data: 24/01/2013

>

HGP HT

AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

60.2
17600 150

70.2
26400 150

80.2
26400 150

90.2
35200 150

100.2
35200 150 m3/h Pa

Cooling OPERATING LIMITS Unit type min max min

Heating max

Outdoor air inlet temperature IP 5 50 -22 42 C Water outlet temperature IP 6 25 30 65 * C * The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
47

> >

HGP HT

AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION AIR - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP A7W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 60.2


Heating capacity Power input 57,5 12,2

70.2
67,8 14,4

80.2
75,7 16,1

90.2
85,4 18,1

100.2
99,5 21,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,71
9923 22 48,5 12,2

4,71
11689 24 57,3 14,4

4,70
13058 24 63,9 16,1

4,72
14737 22 72,1 18,1

4,72
17179 21 84,0 21,1

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,98
8382 16 58,7 15,3

3,98
9888 18 69,1 18,1

3,97
11031 18 77,3 20,2

3,98
12451 16 87,1 22,7

3,98
14512 16 102 26,6

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,84
10156 23

3,82
11966 25

3,83
13380 25

3,84
15070 22

3,83
17587 22

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 60.2


Heating capacity Power input 58,2 15,6

70.2
68,6 18,4

80.2
76,6 20,5

90.2
86,4 23,1

100.2
101 27,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,73
10080 22 49,3 15,5

3,73
11870 24 58,2 18,3

3,74
13260 25 64,9 20,5

3,74
14963 22 73,3 23,1

3,74
17449 22 85,4 27,0

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,18
8551 17 44,6 14,1

3,18
10080 18 52,6 16,6

3,17
11244 18 58,7 18,6

3,17
12704 16 66,2 20,9

3,16
14807 16 77,2 24,5

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,16
7671 14

3,17
9044 15

3,16
10091 15

3,17
11378 14

3,15
13283 14

l/h kPa

IP A7W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 60.2 70.2 80.2
Heating capacity Power input 60,5 23,8 71,2 27,9 79,5 31,3

90.2
89,8 35,3

100.2
105 41,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,54
5293 7 51,8 23,8

2,55
6229 8 61,0 28,0

2,54
6955 8 68,2 31,4

2,54
7856 7 77,0 35,3

2,54
9160 7 89,7 41,3

l/h kPa kW kW

A2W65

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,18
4532 5 59,2 19,1

2,18
5337 6 69,7 22,5

2,17
5967 6 77,8 25,1

2,18
6736 5 87,8 28,3

2,17
7847 5 102 33,1

l/h kPa kW kW

A7W55

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,10
6440 10 50,3 19,1

3,10
7584 11 59,3 22,4

3,10
8466 11 66,3 25,2

3,10
9556 10 74,9 28,4

3,08
11147 10 87,3 33,2

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,63
5481 7

2,65
6462 8

2,63
7213 8

2,64
8150 7

2,63
9502 7

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
48

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HGP HT

AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION

AIR-WATER HEAT PUMPS


90.2 100.2
V-ph-Hz n 4 n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

60.2

70.2

80.2
400 - 3 - 50

scroll with vapour injection (EVI) 2/1 stainless steel brazed plates finned coil plug fan 2 3 2 M 1 1/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

60.2
80 63 54 49

70.2
81 64 54 49

80.2
81 64 55 50

90.2
82 64 55 50

100.2
82 64 56 51 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

60.2
77 60 51 46

70.2
78 61 51 46

80.2
78 61 52 47

90.2
79 61 52 47

100.2
79 61 53 48

The acoustic performances are referred to units operating in cooling mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA

Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

C D E

1200 mm 1000 mm 1000 mm

60.2
A B H 1130 1710 1810

70.2 - 80.2
1130 2430 1810

90.2 - 100.2
1130 3130 1810 mm mm mm
E
D

49

> HSP

AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION


-FRIEND
L

Available range
RE F
R

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable both for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
Cod. BTP00522
50

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with rotary compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fan with electronic control of the rotational speed guarantees high efficiencies and low noise in all the operating conditions and allows to install the unit both outdoor (with protection caps) or indoor (with ducted air inlet and outlet). All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Unit type IP Reversible heat pump

Options
Plant side flow rate management not present standard pump high head pump high efficiency pump Domestic hot water production not present 3 way valve Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Adjustable rubber vibration dampers Protecion caps Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 04

Data: 31/01/2013

>

HSP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

4.1
2400 30

5.1
2400 30

6.1
2400 30

7.1
3650 30

9.1
3650 30

11.1
3650 30 m3/h Pa

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

51

> HSP AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION > HSP AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 4.1
Heating capacity Power input 4,06 0,90

IP A7W35

5.1
4,70 1,09

6.1
5,92 1,35

7.1
7,22 1,70

9.1
8,92 2,06

11.1
10,7 2,58 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,51
703 5 3,37 0,89

4,31
812 7 3,90 1,07

4,39
1023 7 4,91 1,33

4,25
1249 10 6,00 1,67

4,33
1543 10 7,42 2,03

4,15
1853 13 8,92 2,53

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,79
584 4 4,25 1,26

3,64
675 5 4,90 1,52

3,69
850 5 6,19 1,88

3,59
1037 7 7,55 2,36

3,66
1283 7 9,33 2,87

3,53
1543 10 11,2 3,61

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,37
733 6

3,22
847 7

3,29
1069 8

3,20
1304 11

3,25
1612 11

3,10
1931 14

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 4.1


Heating capacity Power input 3,96 1,10

5.1
4,58 1,32

6.1
5,78 1,65

7.1
7,05 2,06

9.1
8,71 2,50

11.1
10,5 3,14 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,60
688 5 3,28 1,09

3,47
796 7 3,79 1,31

3,50
1003 7 4,77 1,62

3,42
1223 10 5,83 2,04

3,48
1512 10 7,21 2,48

3,34
1825 13 8,67 3,09

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,01
570 3 3,29 1,17

2,89
659 5 3,80 1,40

2,94
829 5 4,79 1,74

2,86
1011 7 5,84 2,19

2,91
1251 7 7,22 2,66

2,81
1505 9 8,68 3,34

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

2,81
565 3

2,71
652 5

2,75
822 5

2,67
1004 7

2,71
1241 7

2,60
1491 9

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 4.1 5.1


Heating capacity Power input 3,81 1,28 4,41 1,54

6.1
5,56 1,91

7.1
6,78 2,39

9.1
8,38 2,91

11.1
10,1 3,65 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,98
415 2 3,13 1,27

2,86
481 2 3,62 1,53

2,91
606 3 4,55 1,89

2,84
739 4 5,56 2,37

2,88
913 4 6,87 2,88

2,77
1101 6 8,26 3,60

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,46
341 1

2,37
394 1

2,41
496 2

2,35
606 3

2,39
749 3

2,29
900 4

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
52

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HSP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS
11.1
V-ph-Hz n n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

4.1

5.1

6.1

7.1

9.1

230 - 1 - 50 rotary 1/1 stainless steel brazed plates finned coil plug fan 1 1 M 1 M

ACOUSTIC PERFORMANCES
Unit without accessory Protection caps
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

4.1
67 51 41 35

5.1
68 52 42 36

6.1
69 53 43 37

7.1
70 54 44 38

9.1
71 55 45 39

11.1
71 55 45 39 dB(A) dB(A) dB(A) dB(A)

Unit with accessory Protection caps


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

4.1
63 48 37 32

5.1
64 49 38 33

6.1
65 50 39 34

7.1
66 51 40 35

9.1
67 52 41 36

11.1
67 52 41 36 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. C D 600 mm 600 mm

Outdoor installation

4.1 - 5.1 - 6.1 - 7.1 - 9.1 - 11.1


A1 B1 B2 H 730 730 450 1470 mm mm mm mm

Indoor installation
53

> HXP

AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION


-FRIEND
L

Available range
RE F

Unit type IP Reversible heat pump


(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable both for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
Cod. BTP00430
54

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fan with electronic control of the rotational speed guarantees high efficiencies and low noise in all the operating conditions and allows to install the unit both outdoor (with protection caps) or indoor (with ducted air inlet and outlet). All the units with three-phase power supply are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump high efficiency pump Domestic hot water production not present 3 way valve Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Adjustable rubber vibration dampers Protecion caps Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 07

Data: 31/01/2013

>

HXP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

11.1
4150 30

13.1
4150 30

16.1
4150 30

18.1
7150 50

21.1
7150 50 m3/h Pa

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

55

> HXP AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION > HXP AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 11.1
Heating capacity Power input 11,1 2,65

IP A7W35

13.1
12,8 3,07

16.1
15,3 3,68

18.1
18,1 4,14

21.1
21,0 4,81 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,19
1922 14 9,26 2,60

4,17
2217 18 10,7 3,01

4,16
2632 24 12,7 3,61

4,37
3135 13 15,1 4,07

4,37
3619 17 17,4 4,72

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,56
1600 10 11,7 3,68

3,55
1853 13 13,5 4,27

3,52
2199 18 15,8 5,11

3,71
2615 9 19,1 5,77

3,69
3013 12 21,8 6,70

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,18
2017 15

3,16
2328 19

3,09
2741 25

3,31
3293 14

3,25
3776 19

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 11.1


Heating capacity Power input 10,9 3,21

13.1
12,5 3,72

16.1
15,0 4,47

18.1
17,7 5,04

21.1
20,5 5,85 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,40
1894 14 8,99 3,17

3,36
2172 17 10,4 3,67

3,36
2590 23 12,3 4,40

3,51
3076 13 14,6 4,97

3,50
3545 17 16,9 5,76

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

2,84
1561 10 9,00 3,41

2,83
1807 13 10,4 3,96

2,80
2138 17 12,3 4,73

2,94
2537 9 14,7 5,35

2,93
2937 12 16,9 6,20

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

2,64
1546 10

2,63
1785 13

2,60
2111 17

2,75
2523 9

2,73
2900 11

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 11.1


Heating capacity Power input 10,5 3,73

13.1
12,1 4,32

16.1
14,3 5,16

18.1
17,0 5,84

21.1
19,7 6,77 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

2,82
1144 6 8,57 3,69

2,80
1318 8 9,89 4,28

2,77
1558 10 11,7 5,11

2,91
1852 5 14,0 5,78

2,91
2147 6 16,1 6,71

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,32
934 4

2,31
1077 5

2,29
1275 7

2,42
1525 3

2,40
1754 4

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
56

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HXP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS
21.1
V-ph-Hz n n

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

11.1

13.1
230 - 1 - 50 400 - 3N - 50

16.1

18.1
400 - 3N - 50

scroll 1/1 stainless steel brazed plates finned coil plug fan 1 1 M 1 M 11/4 M

ACOUSTIC PERFORMANCES
Unit without accessory Protection caps
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

11.1
72 56 46 40

13.1
72 56 46 40

16.1
72 57 46 41

18.1
74 59 48 43

21.1
74 59 48 43 dB(A) dB(A) dB(A) dB(A)

Unit with accessory Protection caps


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

11.1
68 53 42 37

13.1
68 53 42 37

16.1
69 54 43 38

18.1
71 55 45 40

21.1
71 55 45 40 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. C D 600 mm 600 mm

Outdoor installation

11.1 - 13.1 - 16.1


A1 B1 B2 H 730 730 450 1470

18.1 - 21.1
880 880 465 1620 mm mm mm mm

Indoor installation
57

> HMP

AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION


-FRIEND
L

Available range
RE F

Unit type IP Reversible heat pump


(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable both for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
Cod. BTP00538
58

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fan (plug fan), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fan with electronic control of the rotational speed guarantees high efficiencies and low noise in all the operating conditions and allows to install the unit both outdoor (with protection caps) or indoor (with ducted air inlet and outlet). All the units with three-phase power supply are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump high efficiency pump Domestic hot water production not present 3 way valve Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Adjustable rubber vibration dampers Protecion caps Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 05

Data: 31/01/2013

>

HMP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

24.1
7150 50

27.1
7850 50

31.1
7850 50

35.1
7850 50

40.1
11400 150

45.1
11400 150 m3/h Pa

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

59

> HMP AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION > HMP AIR - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 24.1
Heating capacity Power input 23,5 5,18

IP A7W35

27.1
26,9 5,81

31.1
30,7 6,79

35.1
34,3 7,75

40.1
39,6 8,72

45.1
45,2 10,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,54
4052 21 19,5 5,08

4,63
4641 18 22,3 5,70

4,52
5299 23 25,6 6,66

4,43
5905 28 28,5 7,59

4,54
6823 25 32,8 8,53

4,52
7793 32 37,5 9,82

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,84
3377 15 24,5 7,20

3,91
3862 13 28,0 8,08

3,84
4416 16 32,0 9,46

3,75
4918 20 35,6 10,8

3,85
5663 18 41,0 12,2

3,82
6477 23 46,9 14,0

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,40
4242 23

3,47
4845 19

3,38
5535 25

3,30
6173 31

3,36
7104 27

3,35
8138 35

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 24.1


Heating capacity Power input 23,0 6,29

27.1
26,3 7,05

31.1
30,0 8,25

35.1
33,5 9,42

40.1
38,5 10,5

45.1
44,1 12,2 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,66
3980 21 18,9 6,19

3,73
4553 17 21,7 6,95

3,64
5196 22 24,9 8,12

3,56
5805 27 27,7 9,25

3,67
6674 24 31,9 10,4

3,61
7629 31 36,4 11,9

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,05
3285 14 19,1 6,65

3,12
3771 12 21,8 7,47

3,07
4310 15 24,8 8,73

2,99
4797 19 27,6 9,95

3,07
5527 17 31,8 11,2

3,06
6309 22 36,4 12,8

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

2,87
3278 14

2,92
3741 12

2,84
4273 15

2,77
4754 19

2,84
5474 17

2,84
6264 22

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 24.1 27.1


Heating capacity Power input 22,0 7,26 25,2 8,16

31.1
28,8 9,51

35.1
32,1 10,8

40.1
37,0 12,2

45.1
42,4 14,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,03
2397 8 18,1 7,19

3,09
2746 7 20,7 8,08

3,03
3138 8 23,6 9,42

2,97
3498 10 26,3 10,7

3,03
4032 9 30,3 12,1

3,03
4609 12 34,7 13,8

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,52
1972 5

2,56
2256 5

2,51
2572 6

2,46
2866 7

2,50
3302 6

2,51
3781 8

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
60

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HMP

AIR-WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION AIR-WATER

HEAT PUMPS
45.1
V-ph-Hz n n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

24.1

27.1

31.1

35.1

40.1

400 - 3N - 50 scroll 1/1 stainless steel brazed plates finned coil plug fan 1 11/4 M 1 M

ACOUSTIC PERFORMANCES
Unit without accessory Protection caps
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

24.1
76 60 50 44

27.1
76 60 50 44

31.1
77 61 51 45

35.1
77 61 51 45

40.1
78 62 52 46

45.1
78 62 52 46 dB(A) dB(A) dB(A) dB(A)

Unit with accessory Protection caps


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

24.1
72 56 46 41

27.1
72 56 46 41

31.1
73 57 47 42

35.1
73 57 47 42

40.1
74 58 48 43

45.1
74 58 48 43 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. C D 600 mm 600 mm

Outdoor installation

24.1
A1 B1 B2 H 880 880 465 1620

27.1 - 31.1 - 35.1


1180 880 465 1620

40.1 - 45.1
1480 880 465 1620 mm mm mm mm

Indoor installation
61

> HGA
Available range

AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION


-FRIEND
L

Unit type IP Reversible heat pump


(reversible on the refrigerant side)

Y
RE F

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for outdoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
Cod. BTP00621
62

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with two scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, axial fans, finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The axial fans, equipped with electronic control of the rotational speed, guarantee high efficiencies in all the operating conditions and the possibility to reduce the noise level during the night. All the units are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Soft starter not present standard

Accessories
Rubber vibration dampers Coil protecion grilles Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 00

Data: 24/01/2013

>

HGA

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

63

> HGA AIR - WATER AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION > HGA HEAT PUMPS FOR OUTDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 45.2
Heating capacity Power input 48,2 10,3

IP A7W35

55.2
55,4 11,9

65.2
65,2 14,0

75.2
72,9 15,7

85.2
82,2 17,7

95.2
95,8 20,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,68
8313 20 40,0 10,1

4,66
9559 20 46,0 11,7

4,66
11257 22 54,1 13,7

4,64
12573 22 60,5 15,4

4,64
14183 20 68,3 17,3

4,63
16538 20 79,6 20,3

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,96
6910 14 50,9 13,2

3,93
7949 15 58,7 15,3

3,95
9352 16 69,0 18,1

3,93
10443 16 77,1 20,2

3,95
11793 14 87,0 22,7

3,92
13750 14 102,0 26,7

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,86
8811 23

3,84
10156 23

3,81
11949 25

3,82
13345 25

3,83
15052 22

3,82
17570 22

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 45.2


Heating capacity Power input 46,9 12,5

55.2
54,1 14,5

65.2
63,7 17,0

75.2
71,1 19,0

85.2
80,2 21,4

95.2
93,6 25,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,75
8133 19 38,8 12,3

3,73
9367 20 44,7 14,3

3,75
11036 21 52,6 16,7

3,74
12322 22 58,7 18,7

3,75
13903 19 66,3 21,0

3,73
16215 19 77,4 24,8

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,15
6726 14 38,7 12,2

3,13
7751 14 44,6 14,1

3,15
9124 15 52,5 16,6

3,14
10184 15 58,6 18,6

3,16
11505 14 66,1 20,9

3,12
13417 14 77,1 24,6

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,17
6659 14

3,16
7671 14

3,16
9027 15

3,15
10074 15

3,16
11361 13

3,13
13266 14

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants 45.2 55.2 Acoustic setting up : AB and AS
Heating capacity Power input 45,1 14,4 51,9 16,7

65.2
61,2 19,7

75.2
68,4 22,1

85.2
77,1 24,8

95.2
90,0 29,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,13
4914 8 37,0 14,3

3,11
5655 8 42,5 16,5

3,11
6658 9 50,1 19,4

3,10
7442 9 56,0 21,8

3,11
8390 8 63,1 24,5

3,10
9796 8 73,6 28,7

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,59
4032 5

2,58
4631 5

2,58
5459 6

2,57
6102 6

2,58
6876 5

2,56
8020 5

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
64

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HGA

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS


85.2 95.2
V-ph-Hz n 4 n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

45.2

55.2

65.2
scroll 2/1

75.2

400 - 3 - 50

stainless steel brazed plates finned coil axial 2 3 2 M 1 1/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

45.2
79 61 52 47

55.2
79 61 52 47

65.2
80 62 53 48

75.2
80 62 53 48

85.2
81 62 54 49

95.2
81 62 54 49 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

45.2
76 58 49 44

55.2
76 58 49 44

65.2
77 59 50 45

75.2
77 59 50 45

85.2
78 59 51 46

95.2
78 59 51 46

The acoustic performances are referred to units operating in cooling mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA

Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

C D E

1200 mm 1000 mm 1000 mm

45.2 - 55.2
A B H 1130 1710 1980

65.2 - 75.2
1130 2430 1980

85.2 - 95.2
1130 3130 1980 mm mm mm
E
D

65

> HGP
Available range

AIR - WATER HEAT PUMPS FOR INDOOR INSTALLATION


-FRIEND
L

Unit type IP Reversible heat pump


(reversible on the refrigerant side)

Y
RE F

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows
66

to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with two scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve, reverse cycle valve, centrifugal fans (plug fans), finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. The plug fans with electronic control of the rotational speed guarantee high efficiencies and low noise in all the operating conditions and allow to install the unit indoor (with ducted air inlet and outlet). It is moreover possible to reduce the noise level during the night. All the units are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump modulating pump Domestic hot water production not present 3 way valve Soft starter not present standard

Accessories
Rubber vibration dampers Coil protecion grilles Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Cod. BTP00625

Rev. 00

Data: 24/01/2013

>

HGP

AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

AERAULIC performances
Nominal air flow rate Nominal available static head

45.2
17600 150

55.2
17600 150

65.2
26400 150

75.2
26400 150

85.2
35200 150

95.2
35200 150 m3/h Pa

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

67

> HGP AIR - WATER AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION > HGP HEAT PUMPS FOR INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 45.2
Heating capacity Power input 48,2 10,3

IP A7W35

55.2
55,4 11,9

65.2
65,2 14,0

75.2
72,9 15,7

85.2
82,2 17,7

95.2
95,8 20,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

4,68
8313 20 40,0 10,1

4,66
9559 20 46,0 11,7

4,66
11257 22 54,1 13,7

4,64
12573 22 60,5 15,4

4,64
14183 20 68,3 17,3

4,63
16538 20 79,6 20,3

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,96
6910 14 50,9 13,2

3,93
7949 15 58,7 15,3

3,95
9352 16 69,0 18,1

3,93
10443 16 77,1 20,2

3,95
11793 14 87,0 22,7

3,92
13750 14 102,0 26,7

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Pressure drops plant side

3,86
8811 23

3,84
10156 23

3,81
11949 25

3,82
13345 25

3,83
15052 22

3,82
17570 22

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 45.2


Heating capacity Power input 46,9 12,5

55.2
54,1 14,5

65.2
63,7 17,0

75.2
71,1 19,0

85.2
80,2 21,4

95.2
93,6 25,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,75
8133 19 38,8 12,3

3,73
9367 20 44,7 14,3

3,75
11036 21 52,6 16,7

3,74
12322 22 58,7 18,7

3,75
13903 19 66,3 21,0

3,73
16215 19 77,4 24,8

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Pressure drops plant side Cooling capacity Power input

3,15
6726 14 38,7 12,2

3,13
7751 14 44,6 14,1

3,15
9124 15 52,5 16,6

3,14
10184 15 58,6 18,6

3,16
11505 14 66,1 20,9

3,12
13417 14 77,1 24,6

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Pressure drops plant side

3,17
6659 14

3,16
7671 14

3,16
9027 15

3,15
10074 15

3,16
11361 13

3,13
13266 14

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants 45.2 55.2 Acoustic setting up : AB and AS
Heating capacity Power input 45,1 14,4 51,9 16,7

65.2
61,2 19,7

75.2
68,4 22,1

85.2
77,1 24,8

95.2
90,0 29,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity Power input

3,13
4914 8 37,0 14,3

3,11
5655 8 42,5 16,5

3,11
6658 9 50,1 19,4

3,10
7442 9 56,0 21,8

3,11
8390 8 63,1 24,5

3,10
9796 8 73,6 28,7

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Pressure drops plant side

2,59
4032 5

2,58
4631 5

2,58
5459 6

2,57
6102 6

2,58
6876 5

2,56
8020 5

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
68

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HGP

AIR-WATER HEAT PUMPS FOR INDOOR INSTALLATION

AIR-WATER HEAT PUMPS


85.2 95.2
V-ph-Hz n 4 n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Hydraulic fittings heat recovery (VD)

45.2

55.2

65.2
scroll 2/1

75.2

400 - 3 - 50

stainless steel brazed plates finned coil plug fan 2 3 2 M 1 1/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

45.2
80 63 54 48

55.2
80 63 54 49

65.2
81 64 54 49

75.2
81 64 55 50

85.2
82 64 55 50

95.2
82 64 56 51 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

45.2
77 60 51 45

55.2
77 60 51 46

65.2
78 61 51 46

75.2
78 61 52 47

85.2
79 61 52 47

95.2
79 61 53 48

The acoustic performances are referred to units operating in cooling mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA

Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

C D E

1200 mm 1000 mm 1000 mm

45.2 - 55.2
A B H 1130 1710 1810

65.2 - 75.2
1130 2430 1810

85.2 - 95.2
1130 3130 1810 mm mm mm
E
D

69

> KSR
Available range

AIR-WATER HEAT PUMPS FOR SPLIT INSTALLATION


-FRIEND
L

Versions VB Base version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for split installation (indoor unit and outdoor unit connected through refrigerant pipes) and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The heat pump is composed by an indoor unit (motocondensing unit) containing the hydraulic circuit, the electrical board, the
70

compressor and a part of the refrigerant circuit and an outdoor unit (remote evaporator). The refrigerant circuit, contained in an extractable box to simplify the maintenance operations, is equipped with rotary compressor mounted on damper supports, brazed plate heat exchanger, thermostatic expansion valve and reverse cycle valve and liquid receiver. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated to avoid condensate generation and to reduce thermal losses. The outdoor structure of the indoor unit and the refrigerant circuit box are both thermally and acoustically insulated in order to create a double wall against sound propagation and to allow the installation in domestic places. To avoid vibration propagation towards the hydraulic circuit the refrigerant circuit box is placed on damper supports and the connection pipes are flexible. The outdoor unit is composed by finned coil made of copper pipes and aluminium louvered fins and axial fan with safety protection grilles. The fan, supplied with DC motor and electronic rotational speed control, guarantees high efficiency and low noise in all the operating conditions. All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric, hydraulic and refrigerant (between indoor and outdoor units) connections are required for installation.

E IG

RA N T

(reversible on the refrigerant side)

Unit type IP Heat pump

RE F

Options
Domestic hot water production not present 3 way valve 3 way valve and primary heat exchanger 3 way valve and secondary heat exchanger Integrative electrical heaters not present standard in the flow Soft starter not present standard Plant buffer tank connections not present standard

Accessories
Rubber vibration dampers Coil protection grille Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Integrated tank Pipes for solar panels connection Refrigerant circuit box

Cod. BTP00474

Rev. 04

Data: 31/01/2013

>

KSR

AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according to the outdoor temperature (climatic control) domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) management of an integrative heating source solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system. Besides the standard user interface present on all the units, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

FS FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : - set point - daily or weekly operating time table - climatic control curve - room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

71

> KSR AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION > KSR AIR - WATER HEAT PUMPS FOR SPLIT INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 3.1
Heating capacity Power input 2,40 0,56

IP A7W35

4.1
3,81 0,89

5.1
5,22 1,24

7.1
6,82 1,61

9.1
8,33 2,00 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

4,29
416 60 2,00 0,55

4,28
660 54 3,16 0,88

4,21
902 47 4,34 1,23

4,24
1179 43 5,67 1,59

4,17
1439 40 6,92 1,96

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Available static headplant side Cooling capacity Power input

3,64
346 62 2,51 0,79

3,59
547 57 3,99 1,25

3,53
750 51 5,45 1,73

3,57
980 48 7,12 2,26

3,53
1197 46 8,69 2,78

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Available static headplant side

3,18
433 60

3,19
688 53

3,15
941 46

3,15
1231 41

3,13
1502 39

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 3.1


Heating capacity Power input 2,35 0,68

4.1
3,72 1,09

5.1
5,10 1,51

7.1
6,66 1,97

9.1
8,14 2,43 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

3,46
408 60 1,94 0,68

3,41
647 54 3,07 1,08

3,38
885 47 4,22 1,50

3,38
1156 43 5,51 1,95

3,35
1411 41 6,72 2,39

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Available static headplant side Cooling capacity Power input

2,85
337 62 1,95 0,73

2,84
534 57 3,09 1,16

2,81
732 52 4,21 1,61

2,83
956 49 5,51 2,09

2,81
1166 47 6,73 2,57

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Available static headplant side

2,67
335 62

2,66
530 58

2,61
724 52

2,64
947 49

2,62
1157 47

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 3.1


Heating capacity Power input 2,26 0,80

4.1
3,58 1,27

5.1
4,90 1,75

7.1
6,40 2,28

9.1
7,82 2,81 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

2,83
246 63 1,85 0,79

2,82
390 60 2,93 1,26

2,80
534 57 4,01 1,74

2,81
697 55 5,25 2,26

2,78
852 54 6,41 2,78

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Available static headplant side

2,34
202 64

2,33
319 62

2,30
437 59

2,32
572 58

2,31
698 57

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
72

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

KSR

AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION

AIR-WATER HEAT PUMPS


7.1
230 - 1 - 50 rotary 1/1
stainless steel brazed plates finned coil

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Refrigerant fittings - liquid line Refrigerant fittings - gas line

3.1
230 - 1 - 50 rotary 1/1
stainless steel brazed plates finned coil

4.1
230 - 1 - 50 rotary 1/1
stainless steel brazed plates finned coil

5.1
230 - 1 - 50 rotary 1/1
stainless steel brazed plates finned coil

9.1
230 - 1 - 50 rotary 1/1
stainless steel brazed plates finned coil

V-ph-Hz n n -

axial 1 1 M 3/8 5/8

axial 1 1 M 3/8 5/8

axial 1 1 M 3/8 5/8

axial 1 1 M 3/8 5/8

axial 1 1 M 3/8 5/8

ACOUSTIC PERFORMANCES
Indoor unit
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

3.1
51 36 25 19

4.1
52 37 26 20

5.1
52 37 26 20

7.1
53 38 27 21

9.1
53 38 27 21 dB(A) dB(A) dB(A) dB(A)

Outdoor unit Base acoustic setting up (AB)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

3.1
68 54 43 37

4.1
68 54 43 37

5.1
68 54 43 37

7.1
71 56 45 40

9.1
71 56 45 40 dB(A) dB(A) dB(A) dB(A)

Outdoor unit Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

3.1
65 51 40 34

4.1
65 51 40 34

5.1
65 51 40 34

7.1
68 53 42 37

9.1
68 53 42 37 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. 3.1
H A B C D E 903 600 300 400 600 200

4.1
903 600 300 400 600 200

5.1
903 600 300 400 600 200

7.1
1153 600 300 400 600 200

9.1
1153 600 300 400 600 200 mm mm mm mm mm mm

Indoor unit with accessory Integrated tank

Indoor unit
B
60 0

60

Outdoor unit
73

852

> KXR
Available range

AIR-WATER HEAT PUMPS FOR SPLIT INSTALLATION


-FRIEND
L

Versions VB Base version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for split installation (indoor unit and outdoor unit connected through refrigerant pipes) and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The heat pump is composed by an indoor unit (motocondensing unit) containing the hydraulic circuit, the electrical board, the
74

compressor and a part of the refrigerant circuit and an outdoor unit (remote evaporator). The refrigerant circuit, contained in an extractable box to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchanger, thermostatic expansion valve and reverse cycle valve and liquid receiver. The circuit is protected by high and low pressure switches and flow switches on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated to avoid condensate generation and to reduce thermal losses. The outdoor structure of the indoor unit and the refrigerant circuit box are both thermally and acoustically insulated in order to create a double wall against sound propagation and to allow the installation in domestic places. To avoid vibration propagation towards the hydraulic circuit the refrigerant circuit box is placed on damper supports and the connection pipes are flexible. The outdoor unit is composed by finned coil made of copper pipes and aluminium louvered fins and axial fan with safety protection grilles. The fan, supplied with DC motor and electronic rotational speed control, guarantees high efficiency and low noise in all the operating conditions. All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All three-phase power supply units are provided with a phase sequence and correct sequence controller device. All the units are accurately built and individually tested in the factory. Only electric,

E IG

RA N T

(reversible on the refrigerant side)

Unit type IP Heat pump

RE F

hydraulic and refrigerant (between indoor and outdoor units) connections are required for installation.

Options
Domestic hot water production not present 3 way valve 3 way valve and primary heat exchanger Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Coil protection grille Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Refrigerant circuit box

Cod. BTP00512

Rev. 03

Data: 31/01/2013

>

KXR

AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according to the outdoor temperature (climatic control) domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) management of an integrative heating source solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system. Besides the standard user interface present on all the units, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

FS FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : - set point - daily or weekly operating time table - climatic control curve - room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
45 25

Unit type
IP IP

min
5 6

min
-20 30

max
42 60 C C

75

> KXR AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION > KXR AIR - WATER HEAT PUMPS FOR SPLIT INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 10.1
Heating capacity Power input 10,1 2,42

IP A7W35

12.1
11,9 2,83

14.1
14,2 3,39

17.1
17,3 4,09

20.1
19,5 4,66 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

4,17
1749 63 8,42 2,38

4,20
2061 63 9,91 2,78

4,19
2459 56 11,8 3,34

4,23
2996 53 14,4 4,03

4,18
3377 46 16,2 4,58

l/h kPa kW kW

A2W35

COP
Water flow rate plant side Available static headplant side Cooling capacity Power input

3,54
1456 69 10,6 3,37

3,56
1714 69 12,5 3,94

3,53
2043 64 14,9 4,74

3,57
2494 61 18,1 5,72

3,54
2805 56 20,4 6,49

l/h kPa kW kW

A35W18

EER
Water flow rate plant side Available static headplant side

3,15
1828 61

3,17
2155 62

3,14
2569 54

3,16
3121 51

3,14
3535 43

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 10.1


Heating capacity Power input 9,90 2,94

12.1
11,6 3,44

14.1
13,9 4,13

17.1
16,9 4,98

20.1
19,1 5,66 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

3,37
1717 63 8,18 2,90

3,37
2016 64 9,64 3,40

3,37
2416 57 11,5 4,07

3,39
2937 54 14,0 4,92

3,37
3319 47 15,8 5,60

l/h kPa kW kW

A2W45

COP
Water flow rate plant side Available static headplant side Cooling capacity Power input

2,82
1420 69 8,19 3,12

2,84
1674 69 9,66 3,66

2,83
1999 64 11,5 4,39

2,85
2433 62 14,0 5,30

2,82
2746 57 15,8 6,02

l/h kPa kW kW

A35W7

EER
Water flow rate plant side Available static headplant side

2,63
1407 70

2,64
1659 70

2,62
1974 65

2,64
2403 63

2,62
2711 58

l/h kPa

IP A7W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 10.1


Heating capacity Power input 9,51 3,41

12.1
11,20 3,99

14.1
13,40 4,79

17.1
16,30 5,78

20.1
18,40 6,57 kW kW

COP
Water flow rate plant side Available static headplant side Heating capacity Power input

2,79
1036 75 7,79 3,38

2,81
1220 75 9,18 3,96

2,80
1460 72 11,0 4,74

2,82
1776 70 13,4 5,73

2,80
2005 67 15,0 6,51

l/h kPa kW kW

A2W55

COP
Water flow rate plant side Available static headplant side

2,30
849 78

2,32
1000 78

2,32
1199 75

2,34
1460 74

2,30
1634 72

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
76

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

KXR

AIR-WATER HEAT PUMPS FOR SPLITTED INSTALLATION

AIR-WATER HEAT PUMPS


17.1
400 - 3N - 50 scroll 1/1
stainless steel brazed plates finned coil

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings Refrigerant fittings - liquid line Refrigerant fittings - gas line

10.1
230 - 1 - 50 400 - 3N - 50 scroll 1/1
stainless steel brazed plates finned coil

12.1
230 - 1 - 50 400 - 3N - 50 scroll 1/1
stainless steel brazed plates finned coil

14.1
400 - 3N - 50 scroll 1/1
stainless steel brazed plates finned coil

20.1
400 - 3N - 50 scroll 1/1
stainless steel brazed plates finned coil

V-ph-Hz n n -

axial 1 1 M 3/8 5/8

axial 1 1 M 3/8 5/8

axial 1 1 M 1/2 3/4

axial 1 1 M 1/2 3/4

axial 1 1 M 1/2 3/4

ACOUSTIC PERFORMANCES
Indoor unit
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

10.1
54 39 29 23

12.1
55 40 30 24

14.1
55 40 30 24

17.1
56 41 31 25

20.1
56 41 31 25 dB(A) dB(A) dB(A) dB(A)

Outdoor unit Base acoustic setting up (AB)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

10.1
71 56 45 40

12.1
71 56 45 40

14.1
73 58 47 42

17.1
73 58 47 42

20.1
73 58 47 42 dB(A) dB(A) dB(A) dB(A)

Outdoor unit Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

10.1
68 53 42 37

12.1
68 53 42 37

14.1
70 55 44 39

17.1
70 55 44 39

20.1
70 55 44 39 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. 10.1
H A B C D E 1153 600 300 400 600 200

12.1
1153 600 300 400 600 200

14.1
1453 600 300 400 600 200

17.1
1453 600 300 400 600 200

20.1
1453 600 300 400 600 200 mm mm mm mm mm mm

60

60

Outdoor unit

Indoor unit
77

1452

> HXA

AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION


-FRIEND
L

Available range
RE F

Unit type IP Reversible heat pump


(reversible on the refrigerant side)

Versions VB Base version Acoustic setting up AB Base setting up

55

Unit description
This series of air-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for outdoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through active cooling (refrigerant circuit inversion). When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production.
Cod. BTP00380
78

The refrigerant circuit, contained in a box repaired from the air flow to simplify the maintenance operations, is equipped with rotary or scroll compressor (according to the model) mounted on damper supports, brazed plate heat exchangers, thermostatic expansion valve, reverse cycle valve, axial fans with safety protection grilles, finned coil realized with copper pipes and alluminium fins. The circuit is protected by high and low pressure switches and differential pressure switch on the plate heat exchanger. The plate heat exchanger and all the hydraulic pipes are thermally insulated in order to avoid condensate generation and reduce thermal losses. All three-phase power supply units are provided with a phase sequence and correct sequence controller device. All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

.0

Options
Plant side flow rate management not present standard pump high head pump high efficiency pump Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Coil protecion grille Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 05

Data: 31/01/2013

>

HXA

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control. The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected. The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

FS

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Outdoor air inlet temperature Water outlet temperature

Heating max
48 25

Unit type
IP IP

min
5 6

min
-15 30

max
42 55 C C

79

> HXA AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION > HXA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 5.1
Heating capacity 4,76 1,21 Power input

IP A7W35

6.1
5,83 1,49

7.1
6,92 1,87

8.1
8,03 2,28

10.1
10,2 2,86

12.1
11,9 3,39

15.1
15,7 4,28

18.1
18,6 5,29 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity

3,93
823 10 3,95 1,19

3,91
1008 15 4,85 1,47

3,70
1195 20 5,75 1,84

3,52
1385 25 6,67 2,24

3,57
1749 37 8,43 2,81

3,51
2043 47 9,85 3,31

3,67
2702 51 13,1 4,17

3,52
3204 46 15,5 5,16

l/h kPa kW kW

A2W35

Power input

COP
Water flow rate plant side Pressure drops plant side Cooling capacity

3,32
684 7 5,12 1,54

3,30
838 11 6,27 1,91

3,13
994 14 7,43 2,39

2,98
1152 18 8,60 2,91

3,00
1453 27 10,8 3,64

2,98
1697 35 12,6 4,32

3,14
2251 38 16,7 5,44

3,00
2667 34 19,8 6,73

l/h kPa kW kW

A35W18

Power input

EER
Water flow rate plant side Pressure drops plant side

3,32
885 12

3,28
1085 17

3,11
1286 22

2,96
1490 28

2,97
1879 41

2,92
2190 53

3,07
2914 58

2,94
3448 52

l/h kPa

IP A7W45

NOMINAL performances - Standard plants Acoustic setting up : AB 5.1


Heating capacity Power input 4,65 1,44

6.1
5,70 1,78

7.1
6,76 2,23

8.1
7,84 2,72

10.1
9,91 3,40

12.1
11,6 4,02

15.1
15,3 5,06

18.1
18,2 6,27 kW kW

COP
Water flow rate plant side Pressure drops plant side Heating capacity

3,23
806 10 3,84 1,42

3,20
989 14 4,72 1,76

3,03
1171 19 5,59 2,20

2,88
1357 24 6,49 2,68

2,91
1712 35 8,19 3,34

2,89
1999 45 9,58 3,95

3,02
2642 49 12,7 4,96

2,90
3146 45 15,1 6,15

l/h kPa kW kW

A2W45

Power input

COP
Water flow rate plant side Pressure drops plant side Cooling capacity

2,70
667 7 4,24 1,50

2,68
819 10 5,20 1,85

2,54
970 14 6,15 2,31

2,42
1124 18 7,14 2,80

2,45
1418 26 8,98 3,50

2,43
1656 33 10,4 4,14

2,56
2190 36 13,9 5,21

2,46
2607 33 16,5 6,46

l/h kPa kW kW

A35W7

Power input

EER
Water flow rate plant side Pressure drops plant side

2,83
729 8

2,81
894 12

2,66
1059 16

2,55
1229 21

2,57
1548 30

2,51
1802 39

2,67
2403 42

2,55
2849 38

l/h kPa

Data declared according to EN 14511. The values are referred to units without options and accessories.
A7W65 = source : air in 7C d.b. 6C w.b. / plant : water in 55C out 65C A7W55 = source : air in 7C d.b. 6C w.b. / plant : water in 47C out 55C A7W45 = source : air in 7C d.b. 6C w.b. / plant : water in 40C out 45C A7W35 = source : air in 7C d.b. 6C w.b. / plant : water in 30C out 35C A35W7 = source : air in 35C d.b. / plant : water in 12C out 7C A35W18 = source : air in 35C d.b. / plant : water in 23C out 18C
80

A2W65 = source : air in 2C d.b. 1C w.b. / plant : water in 55C out 65C A2W55 = source : air in 2C d.b. 1C w.b. / plant : water in 47C out 55C A2W45 = source : air in 2C d.b. 1C w.b. / plant : water in 40C out 45C A2W35 = source : air in 2C d.b. 1C w.b. / plant : water in 30C out 35C

>

HXA

AIR-WATER HEAT PUMPS FOR OUTDOOR INSTALLATION

AIR-WATER HEAT PUMPS


10.1 12.1 15.1 18.1
V-ph-Hz n 2 n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Fans type N fans Hydraulic fittings

5.1

6.1

7.1

8.1

230 - 1 - 50 rotary 1/1

230 - 1 - 50 400 - 3N - 50 scroll

400 - 3N - 50

stainless steel brazed plates finned coil axial 1 1 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

5.1
68 54 43 37

6.1
68 54 43 37

7.1
69 55 44 38

8.1
69 55 44 38

10.1
72 57 46 41

12.1
72 57 46 41

15.1
74 59 48 43

18.1
74 59 48 43 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in heating mode at nominal conditions A7W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

5.1 - 6.1 - 7.1 - 8.1


A B C H

10.1 - 12.1
400 600 200 1150

15.1 - 18.1
mm mm mm mm
81

900

1450

> HMW HT
Available range

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
E

-FRIEND
L

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for indoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. The compressor is equipped with vapour and liquid injection and is placed on an economized refrigerant circuit with plate heat exchanger and electronic expansion valve dedicated to the injection. In the low noise setting up units (AS) the outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. The heat exchangers and all the hydraulic pipes are thermally insulated to avoid condensate generation and reduce thermal losses. All the units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric
Cod. BTP00612
82

E IG

RA N T

Unit type IH Heat pump IP Reversible heat pump

RE F

65

.0

and hydraulic connections are required for installation.

Options
Plant side flow rate management not present standard pump high head pump modulating pump Source side flow rate management not present standard pump high head pump modulating pump 2 way valve Domestic hot water production not present 3 way valve Passive cooling not present standard Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 00

Data: 04/02/2013

>

HMW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat) Cooling Heating max
30 50 50

OPERATING LIMITS
Plant flow temperature Source return temperature (water) Source return temperature (brine)

Unit type
-

min
6 5 -10

min
15 5 -15

max
65 * 25 25 C C C

* The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
83

> >

HMW HMW HT HT

WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 35.1


Heating capacity Power input 35,7 6,74

40.1
42,2 7,92

45.1
47,3 8,98

50.1
53,2 10,1

60.1
62,5 12,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,30
6148 31 8394 55 27,6 6,40

5,33
7273 28 9934 52 32,6 7,53

5,27
8139 35 11135 64 36,6 8,47

5,27
9161 34 12533 62 41,1 9,51

5,21
10737 46 14752 84 48,2 11,2

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,31
4762 19 6818 39 34,8 5,91

4,33
5628 18 8059 37 41,1 6,94

4,32
6321 22 9080 46 45,9 7,83

4,32
7100 21 10193 44 51,7 8,79

4,30
8313 28 11994 60 60,5 10,4

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,89
6035 30 7012 39 34,1 6,03

5,92
7121 27 8274 36 40,3 7,08

5,86
7966 34 9248 45 45,2 8,01

5,88
8966 33 10408 43 50,8 8,98

5,82
10500 44 12154 58 59,4 10,6

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,66
5914 28 7493 46

5,69
6983 26 8849 43

5,64
7828 33 9906 53

5,66
8811 32 11149 51

5,60
10311 43 13007 69

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 35.1


Heating capacity Power input 36,4 6,84

40.1
43,0 8,03

45.1
48,2 9,12

50.1
54,3 10,2

60.1
63,7 12,2 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,32
6269 32 8576 58 28,2 6,48

5,35
7412 29 10143 54 33,2 7,63

5,29
8295 36 11367 67 37,3 8,58

5,32
9352 35 12822 64 42,0 9,64

5,22
10945 47 15066 87 49,1 11,3

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,35
4866 20 6990 41

4,35
5732 18 8227 38

4,35
6442 23 9277 48

4,36
7256 22 10451 46

4,35
8468 29 12249 62

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
84

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HMW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 35.1


Heating capacity Power input 36,5 8,27

40.1
43,1 9,71

45.1
48,3 11,0

50.1
54,3 12,3

60.1
63,8 14,6 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,41
6309 32 8182 53 28,3 7,93

4,44
7456 30 9671 49 33,4 9,33

4,39
8342 37 10835 61 37,4 10,5

4,41
9385 35 12207 59 42,0 11,7

4,37
11001 48 14380 80 49,3 13,7

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,57
4901 20 6547 36 26,5 5,80

3,58
5787 18 7734 34 31,3 6,82

3,56
6482 23 8688 42 35,1 7,65

3,59
7282 22 9767 40 39,5 8,60

3,60
8533 30 11517 55 46,2 9,99

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,57
4565 17 5576 25 26,0 5,90

4,59
5389 16 6581 24 30,7 6,94

4,59
6041 20 7367 29 34,5 7,78

4,59
6796 19 8288 28 38,8 8,74

4,62
7963 26 9674 38 45,4 10,2

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,41
4479 17 5972 30

4,42
5286 16 7048 28

4,43
5938 19 7901 35

4,44
6676 19 8885 33

4,45
7826 25 10370 45

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 35.1


Heating capacity Power input 37,2 8,38

40.1
43,9 9,84

45.1
49,2 11,1

50.1
55,5 12,5

60.1
65,0 14,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,44
6430 33 8359 55 28,9 8,02

4,46
7595 31 9874 51 34,0 9,44

4,43
8498 38 11064 63 38,1 10,6

4,44
9593 37 12493 61 43,1 12,0

4,42
11210 50 14694 83 50,3 13,9

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,60
5005 21 6716 38

3,60
5892 19 7896 35

3,59
6604 24 8876 44

3,59
7456 23 10022 42

3,62
8707 31 11803 58

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
85

> >

HMW HMW HT HT

WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP W10W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 35.1 40.1 45.1
Heating capacity Power input 39,2 11,9 46,4 13,9 51,9 15,6

50.1
58,5 17,6

60.1
68,5 20,4 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,29
3429 10 7919 49 31,1 11,6

3,34
4059 9 9406 47 36,8 13,7

3,33
4541 12 10549 58 41,2 15,2

3,32
5109 11 11864 56 46,3 17,2

3,36
5984 15 14037 76 54,3 19,8

l/h kPa l/h kPa kW kW

B0W65

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

2,68
2721 6 6267 33 37,6 9,75

2,69
3219 6 7413 31 44,5 11,5

2,71
3604 7 8367 39 49,8 12,9

2,69
4051 7 9385 38 56,0 14,4

2,74
4750 10 11167 52 65,6 16,9

l/h kPa l/h kPa kW kW

W10W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,86
4086 14 8056 51 29,3 9,48

3,87
4838 13 9548 48 34,7 11,2

3,86
5415 16 10721 60 38,9 12,5

3,89
6091 16 12064 57 43,7 14,1

3,88
7137 21 14237 79 51,3 16,2

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,09
3193 9 6379 35

3,10
3781 8 7572 32

3,11
4239 10 8526 41

3,10
4762 10 9544 39

3,17
5579 13 11326 54

l/h kPa l/h kPa

IH W10W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 35.1 40.1 45.1
Heating capacity Power input 40,0 12,0 47,3 14,1 53,0 15,9

50.1
59,7 17,8

60.1
69,8 20,6 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,33
3499 10 8119 52 31,8 11,7

3,35
4138 10 9634 49 37,5 13,8

3,33
4628 12 10778 60 42,0 15,5

3,35
5214 12 12150 58 47,4 17,4

3,39
6098 16 14351 80 55,3 20,0

l/h kPa l/h kPa kW kW

B0W65

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

2,72
2782 7 6458 35 38,4 9,88

2,72
3281 6 7604 33 45,3 11,6

2,71
3674 8 8558 41 50,7 13,0

2,72
4147 7 9672 40 57,1 14,7

2,77
4838 10 11421 54 66,8 17,1

l/h kPa l/h kPa kW kW

W10W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,89
4173 15 8259 54 30,0 9,60

3,91
4925 14 9749 50 35,3 11,3

3,90
5514 17 10949 62 39,6 12,7

3,88
6211 16 12322 60 44,7 14,2

3,91
7268 22 14523 82 52,3 16,5

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,13
3269 9 6570 37

3,12
3846 8 7731 34

3,12
4315 11 8685 42

3,15
4871 10 9831 41

3,17
5688 14 11580 56

l/h kPa l/h kPa

86

>

HMW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings Hydraulic fittings heat recovery (VD)

35.1

40.1

45.1
400-3-50

50.1

60.1
V-ph-Hz n -

scroll with vapour injection (EVI) 1/1 stainless steel brazed plates stainless steel brazed plates 11/2 M 11/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

35.1
64 48 38 33

40.1
65 49 39 34

45.1
66 50 40 35

50.1
67 51 41 36

60.1
68 52 42 37 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

35.1
58 42 32 27

40.1
59 43 33 28

45.1
60 44 34 29

50.1
61 45 35 30

60.1
62 46 36 31

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

A B

600 mm 600 mm
B
A

153

100 100 100 100 100 100 100 100

1552

1150

93 790

87

> HGW HT
Available range

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
E

-FRIEND
L

(reversible on the refrigerant side)

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for indoor installation. The possibiliy to produce water at high temperatures makes these units particularly suitable to be applied to radiators plants as well as to fan coil plants and radiant floor plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. Both the compresors are equipped with vapour and liquid injection and are placed on an economized refrigerant circuit equipped with a plate heat exchanger and an electronic expansion valve dedicated to the injection. In the low noise setting up units (AS) the outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. The heat exchangers and all the hydraulic pipes are thermally insulated to avoid condensate generation and reduce thermal losses. All the units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and indiCod. BTP00587
88

E IG

RA N T

Unit type IH Heat pump IP Reversible heat pump

RE F

65

.0

vidually tested in the factory. Only electric and hydraulic connections are required for installation.

Options
Plant side flow rate management not present standard pump high head pump modulating pump Source side flow rate management not present standard pump high head pump modulating pump 2 way valve Domestic hot water production not present 3 way valve Passive cooling not present standard Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Rev. 01

Data: 04/02/2013

>

HGW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat) Cooling Heating max
30 50 50

OPERATING LIMITS
Plant flow temperature Source return temperature (water) Source return temperature (brine)

Unit type
-

min
6 5 -10

min
15 5 -15

max
65 * 25 25 C C C

* The maximum water outlet temperature can be increased up to 70C keeping a DT between inlet and outlet equal to 10C.
89

> >

HGW HGW HT HT

WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 70.2


Heating capacity Power input 69,1 12,7

80.2
81,4 15,0

90.2
91,0 16,8

100.2
102 18,8

120.2
120 22,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,44
11915 31 16267 30 53,5 12,1

5,43
14027 33 19154 33 62,9 14,3

5,42
15673 33 21384 33 70,3 16,1

5,43
17664 30 24128 30 79,1 18,0

5,45
20625 30 28131 30 92,6 21,2

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,42
9230 19 13235 22 67,3 11,3

4,40
10858 21 15557 24 79,1 13,2

4,37
12140 21 17371 24 88,4 14,9

4,39
13664 19 19566 21 99,6 16,6

4,37
15984 19 22843 21 116 19,6

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,96
11656 29 13560 22 66,1 11,4

5,99
13707 32 15932 23 77,6 13,4

5,93
15328 32 17837 24 86,9 15,1

6,00
17259 29 20071 21 97,9 16,9

5,92
20173 29 23483 21 114 19,9

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,80
11449 28 14517 26

5,79
13449 31 17036 28

5,75
15052 31 19086 28

5,79
16949 28 21493 25

5,73
19811 28 25141 25

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 70.2


Heating capacity Power input 70,6 12,8

80.2
83,1 15,2

90.2
92,8 17,1

100.2
105 19,0

120.2
122 22,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,52
12157 32 16638 32 54,5 12,3

5,47
14304 34 19583 34 64,2 14,5

5,43
15984 35 21841 35 71,6 16,4

5,53
18010 31 24643 31 80,8 18,3

5,47
21041 31 28760 31 94,4 21,5

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,43
9404 20 13521 23

4,43
11083 22 15939 25

4,37
12365 22 17721 25

4,42
13941 19 20011 22

4,39
16296 20 23352 22

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
90

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HGW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 70.2


Heating capacity Power input 70,6 15,7

80.2
83,2 18,5

90.2
92,9 20,8

100.2
105 23,1

120.2
122 27,2 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,50
12200 32 15809 29 54,8 15,1

4,50
14373 34 18640 31 64,3 17,9

4,47
16058 35 20784 32 72,0 20,1

4,55
18092 31 23471 28 81,1 22,5

4,49
21133 31 27359 28 94,8 26,4

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,63
9489 20 12694 20 51,4 11,2

3,59
11140 22 14857 22 60,3 13,2

3,58
12461 22 16607 22 67,5 14,8

3,60
14042 20 18739 20 76,0 16,5

3,59
16423 20 21888 20 88,9 19,5

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,59
8838 18 10806 14 50,5 11,3

4,57
10383 19 12694 15 59,2 13,3

4,56
11618 20 14218 16 66,3 15,0

4,61
13077 17 15984 14 74,6 16,8

4,56
15291 17 18721 14 87,3 19,6

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,47
8684 17 11583 17

4,45
10194 19 13595 18

4,42
11412 19 15231 18

4,44
12837 17 17130 16

4,45
15016 17 20045 16

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 70.2


Heating capacity Power input 72,1 15,8

80.2
84,8 18,7

90.2
94,7 21,1

100.2
107 23,5

120.2
125 27,6 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,56
12461 33 16210 30 55,8 15,3

4,53
14651 36 19068 33 65,7 18,1

4,49
16371 36 21241 33 73,4 20,3

4,55
18439 32 23957 29 82,7 22,7

4,53
21568 32 27988 29 96,6 26,7

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,65
9663 21 12948 21

3,63
11383 23 15271 23

3,62
12704 23 16989 23

3,64
14320 20 19184 20

3,62
16736 20 22365 20

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
91

> >

HGW HGW HT HT

WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP W10W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 70.2 80.2 90.2
Heating capacity Power input 76,0 22,7 89,4 26,7 99,9 29,9

100.2
113 33,6

120.2
132 39,5 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,35
6640 10 15352 27 60,3 22,2

3,35
7812 11 18068 30 70,9 26,3

3,34
8731 11 20155 30 79,3 29,4

3,36
9842 10 22756 27 89,3 33,1

3,34
11496 10 26501 27 104 38,9

l/h kPa l/h kPa kW kW

B0W65

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

2,72
5275 7 12185 19 72,7 18,5

2,70
6203 7 14285 20 85,6 21,9

2,70
6938 8 15971 20 95,7 24,5

2,70
7812 7 18007 18 108 27,4

2,67
9133 7 20966 18 126 32,4

l/h kPa l/h kPa kW kW

W10W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,93
7911 14 15609 28 57,0 18,2

3,91
9316 16 18382 31 66,9 21,4

3,91
10406 16 20498 31 74,9 24,1

3,94
11724 14 23128 27 84,3 27,0

3,89
13708 14 26959 27 98,5 31,8

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,13
6200 9 12408 19

3,13
7279 10 14539 21

3,11
8150 10 16257 21

3,12
9175 9 18325 19

3,10
10722 9 21347 19

l/h kPa l/h kPa

IH W10W65

NOMINAL performances - HIGH temperature and VERY HIGH temperature plants Acoustic setting up : AB and AS 70.2 80.2 90.2
Heating capacity Power input 77,5 22,8 91,2 26,9 102 30,4

100.2
115 33,9

120.2
134 39,8 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,40
6771 11 15752 29 61,4 22,5

3,39
7970 12 18525 31 72,3 26,5

3,36
8906 12 20612 31 80,8 29,9

3,39
10035 11 23299 28 91,2 33,5

3,37
11723 11 27159 28 106 39,3

l/h kPa l/h kPa kW kW

B0W65

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

2,73
5372 7 12471 19 74,2 18,7

2,73
6325 8 14666 21 87,3 22,1

2,70
7060 8 16289 21 97,6 24,9

2,72
7970 7 18452 19 110 27,8

2,70
9308 7 21475 19 128 32,7

l/h kPa l/h kPa kW kW

W10W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,97
8074 15 15981 29 58,0 18,4

3,95
9502 16 18811 32 68,3 21,6

3,92
10613 16 20955 32 76,3 24,4

3,96
11953 15 23642 29 86,0 27,3

3,91
13980 15 27588 29 100 32,1

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,15
6309 10 12662 20

3,16
7431 10 14953 22

3,13
8303 11 16607 22

3,15
9360 9 18770 20

3,12
10940 9 21888 20

l/h kPa l/h kPa

92

>

HGW HT

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER HEAT

PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings Hydraulic fittings heat recovery (VD)

70.2

80.2

90.2
400-3-50

100.2

120.2
V-ph-Hz n -

scroll with vapour injection (EVI) 2/1 stainless steel brazed plates stainless steel brazed plates 2 M 11/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

70.2
71 55 45 39

80.2
72 56 46 40

90.2
73 57 47 41

100.2
74 58 48 42

120.2
75 59 49 43 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

70.2
65 49 39 34

80.2
66 50 40 35

90.2
67 51 41 36

100.2
68 52 42 37

120.2
69 53 43 38

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

A B

600 mm 600 mm
B

1652

174

110

110

110

110

110

110

110

110

110 1350 890

93

> HSW

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
-FRIEND
L

Available range
Unit type IH Heat pump IP Reversible heat pump
(reversible on the refrigerant side)

Y
RE F

Versions VB Base version Acoustic setting up AB Base setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed.
94

The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in an extractable box to simplify the maintenance operations, is equipped with rotary compressor mounted on damper supports, brazed plate heat exchangers, thermostatic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The outdoor structure and the refrigerant circuit box are both thermally and acoustically insulated in order to create a double wall against sound propagation and to allow the installation in domestic places. To avoid vibration propagation towards the hydraulic circuit the refrigerant circuit box is placed on damper supports and the connection pipes are flexible. Moreover all the hydraulic pipes are thermally insulated to avoid condensate generation. All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Source side flow rate management not present pump 2 way valve Domestic hot water production not present 3 way valve 3 way valve and primary heat exchanger 3 way valve and secondary heat exchanger Plant buffer tank connections not present standard Passive cooling not present standard Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Integrated tank Pipes for solar panels connection Refrigerant circuit box
Rev. 04 Data: Data: 04/02/2013

Cod. BTP00382

>

HSW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
95

> HSW WATER-WATER AND BRINE BRINE-WATER HEAT PUMPS PUMPSFOR FOR INDOOR INSTALLATION > HSW WATER - WATER AND - WATER HEAT INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 3.1
Heating capacity Power input 3,30 0,58

IP W10W35

5.1
5,01 0,89

7.1
6,72 1,23

9.1
9,13 1,67

11.1
11,6 2,15 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,69
571 59 780 6 2,44 0,57

5,63
866 51 1181 13 3,70 0,88

5,46
1160 41 1578 21 4,97 1,21

5,47
1576 33 2147 24 6,74 1,64

5,40
2009 26 2730 25 8,57 2,12

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,28
423 63 595 4 3,59 0,59

4,20
641 57 900 9 5,43 0,90

4,11
859 51 1199 14 7,27 1,25

4,11
1165 46 1632 16 9,87 1,69

4,04
1481 42 2062 17 12,6 2,17

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

6,08
619 58 722 6 3,51 0,60

6,03
938 49 1094 12 5,30 0,92

5,82
1257 37 1470 19 7,11 1,28

5,84
1709 28 1995 21 9,63 1,72

5,81
2173 21 2541 22 12,3 2,22

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

5,85
605 59 771 7

5,76
916 49 1166 13

5,55
1229 38 1570 22

5,60
1667 30 2127 25

5,54
2121 23 2710 26

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,37 0,59

5.1
5,11 0,89

7.1
6,85 1,24

9.1
9,31 1,69

11.1
11,8 2,18 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,71
584 59 798 7 2,49 0,58

5,74
883 50 1209 14 3,78 0,89

5,52
1183 40 1612 22 5,07 1,23

5,51
1607 32 2193 25 6,88 1,66

5,41
2043 25 2782 26 8,72 2,14

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

4,29
431 63 608 4

4,25
655 57 923 9

4,12
876 50 1228 15

4,14
1190 46 1670 17

4,07
1507 41 2103 17

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
96

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HSW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,03 0,71

5.1
4,61 1,09

7.1
6,19 1,50

9.1
8,40 2,02

11.1
10,6 2,59 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,27
527 60 666 5 2,27 0,69

4,23
799 53 1009 10 3,44 1,06

4,13
1072 44 1347 16 4,62 1,46

4,16
1456 37 1835 19 6,27 1,96

4,09
1842 31 2310 19 7,96 2,53

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,29
395 63 503 3 2,73 0,59

3,25
598 58 760 6 4,13 0,91

3,16
801 53 1009 11 5,54 1,26

3,20
1088 48 1378 12 7,52 1,69

3,15
1382 45 1737 13 9,54 2,16

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,63
469 62 575 4 2,67 0,60

4,54
710 56 873 8 4,05 0,92

4,40
952 48 1174 13 5,42 1,28

4,45
1294 43 1592 15 7,35 1,72

4,42
1641 38 2021 15 9,33 2,21

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

4,45
458 62 615 4

4,40
695 56 933 9

4,23
932 49 1256 15

4,27
1265 44 1702 17

4,22
1605 39 2162 18

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,10 0,72

5.1
4,70 1,10

7.1
6,31 1,51

9.1
8,58 2,04

11.1
10,8 2,62 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,31
539 60 683 5 2,32 0,70

4,27
815 52 1032 10 3,51 1,07

4,18
1093 43 1378 17 4,72 1,47

4,21
1486 36 1878 19 6,40 1,99

4,12
1877 30 2361 20 8,12 2,55

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

3,31
403 63 515 3

3,28
610 58 779 7

3,21
819 52 1037 11

3,22
1111 48 1409 13

3,18
1408 44 1778 13

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
97

> HSW WATER-WATER AND BRINE BRINE-WATER HEAT PUMPS PUMPSFOR FOR INDOOR INSTALLATION > HSW WATER - WATER AND - WATER HEAT INDOOR INSTALLATION
NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB 3.1 5.1
Heating capacity Power input 2,76 0,82 4,19 1,27

IP W10W55

7.1
5,61 1,74

9.1
7,63 2,33

11.1
9,69 3,00 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,37
301 65 555 3 2,10 0,79

3,30
457 62 838 7 3,19 1,21

3,22
611 58 1112 12 4,28 1,67

3,27
830 55 1518 14 5,81 2,24

3,23
1055 52 1918 14 7,37 2,89

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

2,66
229 66 417 2

2,64
348 64 630 5

2,56
466 61 834 8

2,59
633 59 1139 9

2,55
803 58 1432 9

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 3.1


Heating capacity Power input 2,82 0,84

5.1
4,27 1,28

7.1
5,72 1,75

9.1
7,78 2,37

11.1
9,85 3,03 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,36
307 65 566 3 2,15 0,81

3,34
465 61 858 8 3,25 1,23

3,27
623 58 1141 12 4,36 1,68

3,28
847 55 1552 14 5,93 2,27

3,25
1072 52 1955 15 7,50 2,92

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

2,65
234 66 426 2

2,64
354 64 643 5

2,60
475 61 856 8

2,61
646 59 1168 9

2,57
817 57 1463 10

l/h kPa l/h kPa

98

>

HSW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings

3.1

5.1

7.1
230 - 1 - 50 rotary 1/1 stainless steel brazed plates stainless steel brazed plates 1 M

9.1

11.1
V-ph-Hz n -

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

3.1
51 36 25 19

5.1
52 37 26 20

7.1
52 37 26 20

9.1
53 38 27 21

11.1
53 38 27 21 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A 600 mm B 300 mm
B

Unit with accessory Integrated tank


99

> HXW

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
-FRIEND
L

Available range
Unit type IH Heat pump IP Reversible heat pump
(reversible on the refrigerant side)

Y
RE F

Versions VB Base version Acoustic setting up AB Base setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed.
100

The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit, contained in an extractable box to simplify the maintenance operations, is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, thermostatic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The outdoor structure and the refrigerant circuit box are both thermally and acoustically insulated in order to create a double wall against sound propagation and to allow the installation in domestic places. To avoid vibration propagation towards the hydraulic circuit the refrigerant circuit box is placed on damper supports and the connection pipes are flexible. Moreover all the hydraulic pipes are thermally insulated to avoid condensate generation. All the units with three-phase power supply are provided with a phase sequence and correct sequence controller device and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Options
Source side flow rate management not present pump 2 way valve Domestic hot water production not present 3 way valve 3 way valve and primary heat exchanger Passive cooling not present standard Integrative electrical heaters not present standard in the flow Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Refrigerant circuit box

Cod. BTP00407

Rev. 05

Data: Data: 04/02/2013

>

HXW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
101

> HXW WATER-WATER AND BRINE BRINE-WATER HEAT PUMPS PUMPSFOR FOR INDOOR INSTALLATION > HXW WATER - WATER AND - WATER HEAT INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB 12.1
Heating capacity Power input 11,8 2,18

IP W10W35

14.1
14,3 2,66

17.1
16,7 3,10

20.1
20,4 3,82

23.1
23,6 4,43

27.1
26,7 5,02 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,41
2043 56 2773 17 8,71 2,15

5,38
2459 46 3336 24 10,6 2,62

5,39
2892 47 3922 20 12,4 3,07

5,34
3516 33 4774 29 15,0 3,73

5,33
4070 32 5512 25 17,4 4,35

5,32
4607 19 6255 32 19,7 4,90

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,05
1507 68 2093 11 12,8 2,21

4,05
1836 61 2558 15 15,4 2,70

4,04
2147 62 2987 13 18,1 3,14

4,02
2598 54 3617 18 22,0 3,87

4,00
3013 52 4180 16 25,4 4,50

4,02
3412 45 4753 20 28,8 5,09

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,79
2207 53 2586 15 12,5 2,25

5,70
2673 40 3129 21 15,1 2,76

5,76
3138 42 3675 18 17,7 3,22

5,68
3811 25 4459 26 21,6 3,96

5,64
4397 24 5159 22 24,9 4,59

5,66
4983 9 5834 28 28,3 5,21

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

5,56
2155 54 2759 18

5,47
2621 41 3351 25

5,50
3069 44 3926 21

5,45
3742 27 4780 31

5,42
4311 26 5521 26

5,43
4897 12 6258 33

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 12.1


Heating capacity Power input 12,0 2,20

14.1
14,6 2,70

17.1
17,1 3,14

20.1
20,8 3,87

23.1
24,1 4,48

27.1
27,2 5,09 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,45
2078 56 2825 18 8,81 2,17

5,41
2511 44 3413 25 10,8 2,65

5,45
2944 46 3999 21 12,7 3,10

5,37
3585 31 4877 30 15,3 3,77

5,38
4156 30 5643 26 17,7 4,40

5,34
4693 17 6384 33 20,1 4,95

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

4,06
1524 68 2119 11

4,08
1870 60 2612 16

4,10
2199 61 3073 13

4,06
2650 52 3700 19

4,02
3065 52 4263 16

4,06
3464 44 4833 20

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
102

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HXW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 12.1


Heating capacity Power input 10,8 2,63

14.1
13,1 3,21

17.1
15,4 3,76

20.1
18,8 4,58

23.1
21,7 5,34

27.1
24,6 6,02 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,11
1877 60 2350 13 8,10 2,57

4,08
2277 50 2853 18 9,84 3,12

4,10
2676 52 3353 15 11,5 3,67

4,10
3250 39 4080 22 14,0 4,45

4,06
3754 38 4688 18 16,2 5,20

4,09
4258 27 5343 23 18,3 5,83

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,15
1406 69 1763 8 9,71 2,21

3,15
1707 64 2144 11 11,8 2,68

3,13
1999 64 2504 9 13,8 3,14

3,15
2433 57 3061 13 16,8 3,82

3,12
2815 56 3519 11 19,4 4,47

3,14
3180 49 3996 14 21,9 5,02

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,39
1670 65 2061 10 9,50 2,25

4,40
2025 57 2497 14 11,6 2,74

4,39
2368 58 2923 12 13,6 3,21

4,40
2883 48 3554 17 16,5 3,91

4,34
3329 47 4116 14 19,1 4,56

4,36
3775 38 4655 18 21,5 5,14

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

4,22
1634 66 2206 12

4,23
1991 58 2683 17

4,24
2334 59 3148 14

4,22
2832 49 3815 20

4,19
3278 48 4428 17

4,18
3707 39 4998 22

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 12.1


Heating capacity Power input 11,0 2,67

14.1
13,4 3,26

17.1
15,7 3,80

20.1
19,2 4,64

23.1
22,2 5,40

27.1
25,0 6,09 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,12
1912 59 2399 13 8,21 2,59

4,11
2329 49 2927 19 10,0 3,16

4,13
2729 51 3428 16 11,8 3,70

4,14
3319 37 4180 23 14,3 4,49

4,11
3841 36 4817 19 16,5 5,26

4,11
4327 26 5440 24 18,6 5,90

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

3,17
1425 69 1791 8

3,16
1738 63 2189 12

3,19
2051 63 2590 10

3,18
2485 56 3143 14

3,14
2868 55 3598 12

3,15
3233 48 4072 15

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
103

> HXW WATER-WATER AND BRINE BRINE-WATER HEAT PUMPS PUMPSFOR FOR INDOOR INSTALLATION > HXW WATER - WATER AND - WATER HEAT INDOOR INSTALLATION
NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB 12.1 14.1
Heating capacity Power input 9,84 3,07 11,9 3,72

IP W10W55

17.1
14,0 4,36

20.1
17,0 5,28

23.1
19,7 6,19

27.1
22,3 6,94 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,21
1072 75 1941 9 7,50 2,95

3,20
1297 71 2350 13 9,10 3,57

3,21
1525 71 2764 10 10,6 4,20

3,22
1852 66 3368 15 13,0 5,08

3,18
2147 66 3879 13 15,0 5,95

3,21
2430 61 4417 16 17,0 6,66

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

2,54
817 78 1451 5

2,55
992 76 1766 8

2,52
1155 76 2042 6

2,56
1417 73 2529 9

2,52
1634 72 2889 8

2,55
1852 69 3302 10

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 12.1 14.1


Heating capacity Power input 10,0 3,09 12,2 3,76

17.1
14,3 4,41

20.1
17,3 5,34

23.1
20,1 6,25

27.1
22,7 7,01 kW kW

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,24
1090 75 1981 9 7,60 2,98

3,24
1329 71 2424 13 9,30 3,62

3,24
1558 71 2839 11 10,9 4,24

3,24
1885 66 3436 16 13,2 5,13

3,22
2190 65 3977 13 15,3 6,01

3,24
2473 61 4511 17 17,3 6,73

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Available static head plant side Water flow rate source side Pressure drops source side

2,55
828 78 1473 5

2,57
1013 76 1813 8

2,57
1188 76 2125 7

2,57
1438 72 2577 10

2,55
1667 72 2965 8

2,57
1885 69 3375 10

l/h kPa l/h kPa

104

>

HXW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION HEAT WATER-WATER AND BRINE-WATER

PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings

12.1

14.1
230 - 1 - 50 400 - 3N - 50

17.1

20.1

23.1
400 - 3N - 50

27.1
V-ph-Hz n -

scroll 1/1 stainless steel brazed plates stainless steel brazed plates 1 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

12.1
54 39 29 23

14.1
54 39 29 23

17.1
55 40 30 24

20.1
55 40 30 24

23.1
56 41 31 25

27.1
56 41 31 25 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 300 mm

105

> HMW
Available range

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
-FRIEND
L

Unit type IH Heat pump IP Reversible heat pump


(reversible on the refrigerant side)

Y
RE F

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. In the low noise setting up units (AS) the outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. The heat exchangers and all the hydraulic pipes are thermally insulated to avoid condensate generation and reduce thermal losses. All the units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

106

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump modulating pump Source side flow rate management not present standard pump high head pump modulating pump 2 way valve Domestic hot water production not present 3 way valve Passive cooling not present standard Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Cod. BTP00610

Rev. 02

Data: 04/02/2013

>

HMW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
107

> HMW > HMW

WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 30.1


Heating capacity Power input 28,2 5,13

35.1
32,4 5,93

40.1
38,2 7,01

45.1
42,7 7,90

50.1
48,1 8,86

55.1
56,4 10,5 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,50
4866 20 6655 36 21,6 5,02

5,46
5594 26 7670 47 24,9 5,76

5,45
6598 24 9031 43 29,4 6,84

5,41
7360 29 10089 53 32,9 7,64

5,43
8295 28 11378 51 37,0 8,57

5,37
9715 38 13368 70 43,4 10,1

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,30
3741 12 5326 25 30,5 5,18

4,32
4295 16 6134 32 34,9 5,97

4,30
5074 14 7231 30 41,2 7,07

4,31
5680 18 8122 37 46,0 7,95

4,32
6390 17 9140 36 51,8 8,90

4,30
7481 23 10744 48 60,6 10,6

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,89
5276 23 6146 30 30,1 5,22

5,85
6052 30 7040 39 34,5 6,04

5,83
7138 28 8314 37 40,8 7,15

5,79
7983 34 9284 45 45,6 8,06

5,82
8983 33 10444 43 51,3 9,02

5,72
10518 44 12204 58 60,1 10,7

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,77
5207 22 6598 36

5,71
5983 29 7569 47

5,71
7069 27 8953 44

5,66
7897 33 9987 54

5,69
8897 32 11247 52

5,62
10431 43 13157 70

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 30.1


Heating capacity Power input 28,8 5,20

35.1
33,0 6,02

40.1
39,0 7,11

45.1
43,6 8,02

50.1
49,1 8,99

55.1
57,6 10,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,54
4970 20 6813 37 22,1 5,09

5,48
5698 26 7825 48 25,4 5,84

5,49
6719 24 9211 45 30,0 6,92

5,44
7516 30 10326 56 33,6 7,74

5,46
8468 29 11641 54 37,8 8,68

5,38
9906 39 13657 73 44,2 10,2

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,34
3827 12 5469 26

4,35
4381 16 6274 34

4,34
5178 15 7400 31

4,34
5801 19 8323 39

4,35
6529 18 9369 37

4,33
7620 24 10970 50

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
108

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HMW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 30.1


Heating capacity Power input 26,0 6,14

35.1
29,8 7,05

40.1
35,1 8,35

45.1
39,3 9,34

50.1
44,3 10,50

55.1
51,9 12,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,23
4501 17 5709 27 20,1 5,97

4,23
5162 22 6567 35 23,2 6,82

4,20
6083 20 7716 32 27,3 8,10

4,21
6795 25 8642 40 30,6 9,01

4,22
7664 24 9757 38 34,4 10,1

4,22
8968 32 11464 52 40,3 11,8

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,37
3493 10 4530 18 23,2 5,13

3,40
4015 14 5233 24 26,6 5,87

3,37
4727 13 6134 22 31,4 6,96

3,40
5301 16 6916 27 35,2 7,77

3,41
5961 15 7779 26 39,6 8,71

3,42
6986 20 9163 36 46,2 10,2

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,52
3999 14 4899 20 23,0 5,15

4,53
4582 18 5604 26 26,3 5,90

4,51
5406 16 6621 24 31,1 7,00

4,53
6058 20 7403 29 34,8 7,82

4,55
6813 19 8325 28 39,2 8,77

4,53
7963 26 9707 38 45,9 10,3

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,47
3947 13 5263 24

4,46
4531 17 6029 31

4,44
5354 16 7132 29

4,45
5989 20 7963 35

4,47
6744 19 8964 34

4,46
7911 26 10483 46

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 30.1


Heating capacity Power input 26,5 6,21

35.1
30,4 7,14

40.1
35,9 8,47

45.1
40,2 9,47

50.1
45,2 10,7

55.1
52,9 12,5 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,27
4588 17 5835 28 20,6 6,04

4,26
5266 23 6718 36 23,6 6,90

4,24
6222 21 7919 34 27,9 8,19

4,24
6952 26 8874 42 31,2 9,12

4,22
7821 25 9977 40 35,1 10,2

4,23
9141 34 11721 54 41,0 12,0

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,41
3580 11 4670 19

3,42
4084 14 5338 25

3,41
4831 13 6299 23

3,42
5405 16 7079 29

3,44
6083 16 7969 28

3,42
7108 21 9353 37

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
109

> HMW WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION > HMW WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB and AS 30.1 35.1
Heating capacity Power input 23,5 7,09 27,0 8,07

IP W10W55

40.1
31,9 9,61

45.1
35,6 10,7

50.1
40,1 12,0

55.1
47,1 14,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,31
2561 6 4717 19 18,6 6,81

3,35
2942 7 5452 24 21,4 7,75

3,32
3476 7 6418 23 25,2 9,21

3,33
3879 9 7176 28 28,3 10,2

3,34
4369 8 8090 27 31,8 11,5

3,36
5121 11 9548 37 37,3 13,3

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,73
2027 4 3767 13

2,76
2332 5 4368 17

2,74
2746 4 5113 15

2,77
3084 6 5790 20

2,77
3465 5 6490 19

2,80
4064 7 7699 26

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB and AS 30.1 35.1
Heating capacity Power input 24,0 7,17 27,5 8,17

40.1
32,5 9,72

45.1
36,4 10,8

50.1
41,0 12,2

55.1
48,0 14,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,35
2615 6 4840 20 19,1 6,89

3,37
2996 8 5569 25 21,8 7,83

3,34
3541 7 6561 24 25,8 9,32

3,37
3966 9 7376 29 28,9 10,3

3,36
4468 9 8319 28 32,5 11,6

3,40
5219 12 9777 39 38,0 13,4

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,77
2081 4 3904 14

2,78
2375 5 4470 18

2,77
2811 5 5272 16

2,81
3149 6 5949 21

2,80
3541 6 6681 20

2,84
4141 8 7890 27

l/h kPa l/h kPa

110

>

HMW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS
55.1
V-ph-Hz n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings Hydraulic fittings heat recovery (VD)

30.1

35.1

40.1
400-3-50 scroll 1/1

45.1

50.1

stainless steel brazed plates stainless steel brazed plates 11/2 M 11/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

30.1
63 47 37 32

35.1
64 48 38 33

40.1
65 49 39 34

45.1
66 50 40 35

50.1
67 51 41 36

55.1
68 52 42 37 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

30.1
57 41 31 26

35.1
58 42 32 27

40.1
59 43 33 28

45.1
60 44 34 29

50.1
61 45 35 30

55.1
62 46 36 31

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

A B

600 mm 600 mm
B
A

153

100 100 100 100 100 100 100 100

1552

1150

93 790

111

> HGW
Available range

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
-FRIEND
L

Unit type IH Heat pump IP Reversible heat pump


(reversible on the refrigerant side)

Y
RE F

Versions (heat recovery) VB Base version VD Desuperheater version Acoustic setting up AB Base setting up AS Low noise setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of autonomous or centralized residential plants of medium and large size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. During cooling mode operation a part of the heating power in excess can be recovered for the domestic hot water production (VD version). The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressors mounted on damper supports, brazed plate heat exchangers, electronic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The compressors are arranged in tandem on a single refrigerant circuit and allow the capacity modulation according to the plant requests in order to guarantee a high seasonal efficiency. In the low noise setting up units (AS) the outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. The heat exchangers and all the hydraulic pipes are thermally insulated to avoid condensate generation and reduce thermal losses. All the units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

112

E IG

RA N T

Options
Plant side flow rate management not present standard pump high head pump modulating pump Source side flow rate management not present standard pump high head pump modulating pump 2 way valve Domestic hot water production not present 3 way valve Passive cooling not present standard Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor

Cod. BTP00568

Rev. 04

Data: 04/02/2013

>

HGW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16) The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
113

> HGW WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION > HGW WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 55.2
Heating capacity Power input 53,1 9,62

IP W10W35

65.2
61,3 11,1

75.2
72,9 13,1

85.2
82,7 14,9

95.2
91,3 16,3

110.2
107 19,4 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,52
9161 24 12510 24 40,8 9,48

5,52
10581 25 14466 24 47,1 10,9

5,56
12573 27 17210 27 56,1 12,9

5,55
14253 28 19526 28 63,6 14,6

5,60
15742 24 21556 24 70,2 16,0

5,52
18495 25 25272 24 82,4 19,1

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,30
7048 15 10012 17 57,2 9,76

4,32
8139 15 11580 17 66,1 11,3

4,35
9681 17 13807 19 78,5 13,2

4,36
10979 18 15684 20 89,0 15,1

4,39
12122 15 17307 17 98,5 16,5

4,31
14235 15 20234 17 116 19,7

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,86
9914 28 11565 21 56,7 9,81

5,85
11449 28 13352 21 65,5 11,3

5,95
13604 31 15828 23 77,8 13,4

5,89
15432 33 17959 24 88,1 15,2

5,97
17052 28 19846 21 97,5 16,7

5,89
20018 28 23344 21 114 19,8

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,78
9828 28 12463 25

5,80
11345 28 14385 25

5,81
13483 31 17074 28

5,80
15277 32 19330 29

5,84
16880 28 21380 25

5,76
19811 28 25122 25

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB and AS 55.2


Heating capacity Power input 54,2 9,7

65.2
62,6 11,2

75.2
74,4 13,3

85.2
84,4 15,0

95.2
93,1 16,5

110.2
109 19,6 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,56
9352 25 12799 25 41,6 9,6

5,59
10789 25 14780 25 48,0 11,0

5,59
12832 28 17610 28 57,3 13,0

5,63
14547 29 19983 29 64,9 14,7

5,64
16054 25 22042 25 71,6 16,2

5,56
18859 25 25815 25 84,1 19,4

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,34
7187 16 10238 17

4,36
8295 16 11835 18

4,41
9888 18 14157 20

4,41
11205 18 16066 21

4,42
12365 16 17721 18

4,34
14530 16 20711 18

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
114

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HGW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 55.2


Heating capacity Power input 48,9 11,6

65.2
56,4 13,4

75.2
67,1 15,7

85.2
76,0 17,8

95.2
84,0 19,6

110.2
98,6 23,4 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,22
8464 21 10692 18 38,0 11,3

4,21
9767 21 12350 18 43,8 13,0

4,27
11609 23 14752 20 52,1 15,4

4,27
13156 24 16724 21 59,0 17,3

4,29
14546 21 18497 18 65,2 19,2

4,21
17084 21 21613 18 76,6 22,8

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,36
6587 13 8526 12 43,7 9,69

3,37
7595 13 9831 13 50,5 11,2

3,38
9037 15 11739 14 59,9 13,2

3,41
10236 15 13330 15 68,0 14,9

3,40
11314 13 14698 12 75,1 16,4

3,36
13278 13 17180 12 88,2 19,5

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,51
7517 17 9223 13 43,3 9,72

4,51
8684 17 10650 14 50,0 11,2

4,54
10314 19 12625 15 59,3 13,3

4,56
11704 20 14322 16 67,3 15,0

4,58
12922 17 15811 13 74,3 16,6

4,52
15171 17 18599 14 87,3 19,5

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,45
7448 17 9940 16

4,46
8598 17 11470 16

4,46
10211 19 13614 18

4,49
11584 19 15419 19

4,48
12785 17 17036 16

4,48
15016 17 20026 16

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB and AS 55.2


Heating capacity Power input 49,9 11,8

65.2
57,5 13,5

75.2
68,5 16,0

85.2
77,6 18,1

95.2
85,7 19,8

110.2
101 23,6 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,23
8637 22 10949 19 38,7 11,4

4,26
9958 22 12636 19 44,7 13,1

4,28
11853 24 15095 21 53,2 15,5

4,29
13434 25 17124 22 60,3 17,5

4,33
14842 22 18925 19 66,5 19,3

4,28
17414 22 22099 19 78,2 23,0

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,39
6708 14 8717 13

3,41
7751 14 10085 13

3,43
9228 15 12058 15

3,45
10445 16 13648 15

3,45
11540 14 15080 13

3,40
13556 14 17625 13

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
115

> HGW WATER-WATER HEAT PUMPS FOR INDOOR INSTALLATION > HGW WATER - WATERAND ANDBRINE-WATER BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION
NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB and AS 55.2 65.2
Heating capacity Power input 44,3 13,4 51,1 15,5

IP W10W55

75.2
60,9 18,2

85.2
69,0 20,6

95.2
76,3 22,6

110.2
89,5 27,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,31
4827 7 8862 13 35,1 12,9

3,30
5568 8 10235 13 40,5 14,9

3,35
6625 8 12236 14 48,2 17,5

3,35
7508 9 13894 15 54,6 19,8

3,38
8303 8 15380 13 60,4 21,8

3,31
9741 8 17925 13 70,9 26,0

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,72
3825 5 7095 9

2,72
4413 5 8176 9

2,75
5252 6 9799 10

2,76
5949 6 11103 10

2,77
6581 5 12312 9

2,73
7726 5 14348 9

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB and AS 55.2 65.2
Heating capacity Power input 45,2 13,5 52,1 15,6

75.2
62,2 18,4

85.2
70,4 20,8

95.2
77,8 22,9

110.2
91,3 27,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,35
4925 8 9091 13 35,8 13,0

3,34
5677 8 10492 13 41,3 15,0

3,38
6767 9 12550 15 49,2 17,7

3,38
7660 9 14237 16 55,7 19,9

3,40
8466 8 15752 13 61,6 22,0

3,34
9937 8 18354 13 72,3 26,3

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,75
3901 5 7285 9

2,75
4500 5 8399 9

2,78
5361 6 10053 10

2,80
6069 6 11421 11

2,80
6712 5 12630 9

2,75
7878 5 14698 9

l/h kPa l/h kPa

116

>

HGW

WATER-WATER AND BRINE-WATER HEAT PUMPS FOR INDOOR INSTALLATION WATER-WATER AND BRINE-WATER

HEAT PUMPS
110.2
V-ph-Hz n -

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings Hydraulic fittings heat recovery (VD)

55.2

65.2

75.2
400-3-50 scroll 2/1

85.2

95.2

stainless steel brazed plates stainless steel brazed plates 2 M 11/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

55.2
70 54 44 38

65.2
71 55 45 39

75.2
72 56 46 40

85.2
73 57 47 41

95.2
74 58 48 42

110.2
75 59 49 43 dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)

Low noise acoustic setting up (AS)


Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

55.2
64 48 38 33

65.2
65 49 39 34

75.2
66 50 40 35

85.2
67 51 41 36

95.2
68 52 42 37

110.2
69 53 43 38

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

A B

600 mm 600 mm
B

1652

174

110

110

110

110

110

110

110

110

110 1350 890

117

> HSW LT

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
-FRIEND
L

Y
RE F

Unit type IH Heat pump IP Reversible heat pump


(reversible on the refrigerant side)

Versions VB Base version Acoustic setting up AB Base setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in
Cod. BTP00559
118

radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with rotary compressor mounted on damper supports, brazed plate heat exchangers, thermostatic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. All the hydraulic pipes are thermally insulated to avoid condensate generation. All the units are supplied with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Available range

Options
Plant side flow rate management not present standard pump high head pump modulating pump Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Plant tank

Rev. 03

Data: 04/02/2013

>

HSW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
119

> >

HSW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,30 0,58

5.1
5,01 0,89

7.1
6,72 1,23

9.1
9,13 1,67

11.1
11,6 2,15 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,69
571 5 780 6 2,44 0,57

5,63
866 11 1181 13 3,70 0,88

5,46
1160 19 1578 21 4,97 1,21

5,47
1576 21 2147 24 6,74 1,64

5,40
2009 22 2730 25 8,57 2,12

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,28
423 2 595 4 3,59 0,59

4,20
641 7 900 9 5,43 0,90

4,11
859 11 1199 14 7,27 1,25

4,11
1165 13 1632 16 9,87 1,69

4,04
1481 13 2062 17 12,6 2,17

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

6,08
619 6 722 6 3,51 0,60

6,03
938 13 1094 12 5,30 0,92

5,82
1257 21 1470 19 7,11 1,28

5,84
1709 24 1995 21 9,63 1,72

5,81
2173 25 2541 22 12,3 2,22

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,85
605 6 771 7

5,76
916 13 1166 13

5,55
1229 21 1570 22

5,60
1667 23 2127 25

5,54
2121 24 2710 26

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,37 0,59

5.1
5,11 0,89

7.1
6,85 1,24

9.1
9,31 1,69

11.1
11,8 2,18 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,71
584 5 798 7 2,49 0,58

5,74
883 12 1209 14 3,78 0,89

5,52
1183 19 1612 22 5,07 1,23

5,51
1607 22 2193 25 6,88 1,66

5,41
2043 22 2782 26 8,72 2,14

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,29
431 3 608 4

4,25
655 7 923 9

4,12
876 12 1228 15

4,14
1190 13 1670 17

4,07
1507 13 2103 17

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
120

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HSW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,03 0,71

5.1
4,61 1,09

7.1
6,19 1,50

9.1
8,40 2,02

11.1
10,6 2,59 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,27
527 4 666 5 2,27 0,69

4,23
799 10 1009 10 3,44 1,06

4,13
1072 16 1347 16 4,62 1,46

4,16
1456 18 1835 19 6,27 1,96

4,09
1842 19 2310 19 7,96 2,53

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,29
395 2 503 3 2,73 0,59

3,25
598 6 760 6 4,13 0,91

3,16
801 10 1009 11 5,54 1,26

3,20
1088 11 1378 12 7,52 1,69

3,15
1382 12 1737 13 9,54 2,16

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,63
469 3 575 4 2,67 0,60

4,54
710 8 873 8 4,05 0,92

4,40
952 13 1174 13 5,42 1,28

4,45
1294 15 1592 15 7,35 1,72

4,42
1641 16 2021 15 9,33 2,21

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,45
458 3 615 4

4,40
695 8 933 9

4,23
932 13 1256 15

4,27
1265 15 1702 17

4,22
1605 15 2162 18

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 3.1


Heating capacity Power input 3,10 0,72

5.1
4,70 1,10

7.1
6,31 1,51

9.1
8,58 2,04

11.1
10,8 2,62 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,31
539 5 683 5 2,32 0,70

4,27
815 10 1032 10 3,51 1,07

4,18
1093 17 1378 17 4,72 1,47

4,21
1486 19 1878 19 6,40 1,99

4,12
1877 19 2361 20 8,12 2,55

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,31
403 2 515 3

3,28
610 6 779 7

3,21
819 10 1037 11

3,22
1111 12 1409 13

3,18
1408 12 1778 13

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
121

> >

HSW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W55

NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB 3.1 5.1
Heating capacity Power input 2,76 0,82 4,19 1,27

7.1
5,61 1,74

9.1
7,63 2,33

11.1
9,69 3,00 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,37
301 1 555 3 2,10 0,79

3,30
457 3 838 7 3,19 1,21

3,22
611 6 1112 12 4,28 1,67

3,27
830 7 1518 14 5,81 2,24

3,23
1055 7 1918 14 7,37 2,89

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,66
229 1 417 2

2,64
348 1 630 5

2,56
466 3 834 8

2,59
633 4 1139 9

2,55
803 5 1432 9

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 3.1


Heating capacity Power input 2,82 0,84

5.1
4,27 1,28

7.1
5,72 1,75

9.1
7,78 2,37

11.1
9,85 3,03 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,36
307 1 566 3 2,15 0,81

3,34
465 3 858 8 3,25 1,23

3,27
623 6 1141 12 4,36 1,68

3,28
847 7 1552 14 5,93 2,27

3,25
1072 8 1955 15 7,50 2,92

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,65
234 1 426 2

2,64
354 1 643 5

2,60
475 3 856 8

2,61
646 4 1168 9

2,57
817 5 1463 10

l/h kPa l/h kPa

122

>

HSW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings

3.1

5.1

7.1
230 - 1 - 50 rotary 1/1 stainless steel brazed plates stainless steel brazed plates 1 M

9.1

11.1
V-ph-Hz n -

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

3.1
60 46 34 28

5.1
61 47 35 29

7.1
61 47 35 29

9.1
62 48 36 30

11.1
62 48 36 30 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
116

670

84 7

A
201 292 705 212

70 70 70

364 377

Unit with accessory Plant tank

116

1089

A
201 292 705 212

159

145

200

70 70 70

116 7

145 364 377

116 7

123

> HXW LT

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
-FRIEND
L

Y
RE F

Unit type IH Heat pump IP Reversible heat pump


(reversible on the refrigerant side)

Versions VB Base version Acoustic setting up AB Base setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for outdoor or indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in
Cod. BTP00561
124

radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, thermostatic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. All the hydraulic pipes are thermally insulated to avoid condensate generation. All the three phase electrical power supply units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Available range

Options
Plant side flow rate management not present standard pump high head pump modulating pump Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Plant tank

Rev. 03

Data: 04/02/2013

>

HXW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
125

> >

HXW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 12.1


Heating capacity Power input 11,8 2,18

14.1
14,3 2,66

17.1
16,7 3,10

20.1
20,4 3,82

23.1
23,6 4,43

27.1
26,7 5,02 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,41
2043 17 2773 17 8,71 2,15

5,38
2459 24 3336 24 10,6 2,62

5,39
2892 18 3922 20 12,4 3,07

5,34
3516 27 4774 29 15,0 3,73

5,33
4070 22 5512 25 17,4 4,35

5,32
4607 27 6255 32 19,7 4,90

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,05
1507 9 2093 11 12,8 2,21

4,05
1836 14 2558 15 15,4 2,70

4,04
2147 11 2987 13 18,1 3,14

4,02
2598 15 3617 18 22,0 3,87

4,00
3013 12 4180 16 25,4 4,50

4,02
3412 15 4753 20 28,8 5,09

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,79
2207 20 2586 15 12,5 2,25

5,70
2673 28 3129 21 15,1 2,76

5,76
3138 22 3675 18 17,7 3,22

5,68
3811 31 4459 26 21,6 3,96

5,64
4397 25 5159 22 24,9 4,59

5,66
4983 32 5834 28 28,3 5,21

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,56
2155 19 2759 18

5,47
2621 27 3351 25

5,50
3069 21 3926 21

5,45
3742 30 4780 31

5,42
4311 24 5521 26

5,43
4897 31 6258 33

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 12.1


Heating capacity Power input 12,0 2,20

14.1
14,6 2,70

17.1
17,1 3,14

20.1
20,8 3,87

23.1
24,1 4,48

27.1
27,2 5,09 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,45
2078 17 2825 18 8,81 2,17

5,41
2511 25 3413 25 10,8 2,65

5,45
2944 19 3999 21 12,7 3,10

5,37
3585 28 4877 30 15,3 3,77

5,38
4156 22 5643 26 17,7 4,40

5,34
4693 28 6384 33 20,1 4,95

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,06
1524 10 2119 11

4,08
1870 14 2612 16

4,10
2199 11 3073 13

4,06
2650 16 3700 19

4,02
3065 13 4263 16

4,06
3464 16 4833 20

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
126

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HXW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 12.1


Heating capacity Power input 10,8 2,63

14.1
13,1 3,21

17.1
15,4 3,76

20.1
18,8 4,58

23.1
21,7 5,34

27.1
24,6 6,02 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,11
1877 14 2350 13 8,10 2,57

4,08
2277 21 2853 18 9,84 3,12

4,10
2676 16 3353 15 11,5 3,67

4,10
3250 23 4080 22 14,0 4,45

4,06
3754 18 4688 18 16,2 5,20

4,09
4258 23 5343 23 18,3 5,83

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,15
1406 8 1763 8 9,71 2,21

3,15
1707 12 2144 11 11,8 2,68

3,13
1999 9 2504 9 13,8 3,14

3,15
2433 13 3061 13 16,8 3,82

3,12
2815 11 3519 11 19,4 4,47

3,14
3180 13 3996 14 21,9 5,02

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,39
1670 12 2061 10 9,50 2,25

4,40
2025 17 2497 14 11,6 2,74

4,39
2368 13 2923 12 13,6 3,21

4,40
2883 18 3554 17 16,5 3,91

4,34
3329 15 4116 14 19,1 4,56

4,36
3775 19 4655 18 21,5 5,14

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,22
1634 11 2206 12

4,23
1991 16 2683 17

4,24
2334 12 3148 14

4,22
2832 18 3815 20

4,19
3278 14 4428 17

4,18
3707 18 4998 22

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 12.1


Heating capacity Power input 11,0 2,67

14.1
13,4 3,26

17.1
15,7 3,80

20.1
19,2 4,64

23.1
22,2 5,40

27.1
25,0 6,09 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,12
1912 15 2399 13 8,21 2,59

4,11
2329 22 2927 19 10,0 3,16

4,13
2729 16 3428 16 11,8 3,70

4,14
3319 24 4180 23 14,3 4,49

4,11
3841 19 4817 19 16,5 5,26

4,11
4327 24 5440 24 18,6 5,90

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,17
1425 8 1791 8

3,16
1738 12 2189 12

3,19
2051 10 2590 10

3,18
2485 14 3143 14

3,14
2868 11 3598 12

3,15
3233 14 4072 15

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
127

> >

HXW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W55

NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB 12.1 14.1
Heating capacity Power input 9,84 3,07 11,9 3,72

17.1
14,0 4,36

20.1
17,0 5,28

23.1
19,7 6,19

27.1
22,3 6,94 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,21
1072 5 1941 9 7,50 2,95

3,20
1297 7 2350 13 9,10 3,57

3,21
1525 5 2764 10 10,6 4,20

3,22
1852 8 3368 15 13,0 5,08

3,18
2147 6 3879 13 15,0 5,95

3,21
2430 8 4417 16 17,0 6,66

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,54
817 3 1451 5

2,55
992 4 1766 8

2,52
1155 3 2042 6

2,56
1417 5 2529 9

2,52
1634 4 2889 8

2,55
1852 5 3302 10

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 12.1 14.1


Heating capacity Power input 10,0 3,09 12,2 3,76

17.1
14,3 4,41

20.1
17,3 5,34

23.1
20,1 6,25

27.1
22,7 7,01 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,24
1090 5 1981 9 7,60 2,98

3,24
1329 7 2424 13 9,30 3,62

3,24
1558 6 2839 11 10,9 4,24

3,24
1885 8 3436 16 13,2 5,13

3,22
2190 7 3977 13 15,3 6,01

3,24
2473 8 4511 17 17,3 6,73

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,55
828 3 1473 5

2,57
1013 4 1813 8

2,57
1188 3 2125 7

2,57
1438 5 2577 10

2,55
1667 4 2965 8

2,57
1885 5 3375 10

l/h kPa l/h kPa

128

>

HXW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings

12.1

14.1
230-1-50 400-3N-50

17.1

20.1

23.1
400-3N-50

27.1
V-ph-Hz n -

scroll 1/1 stainless steel brazed plates stainless steel brazed plates 1 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

12.1
63 50 38 32

14.1
63 50 38 32

17.1
64 51 39 33

20.1
64 51 39 33

23.1
65 52 40 34

27.1
65 52 40 34 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
116

670

B
A
201 292 705 212

84 7

70 70 70

509 522

Unit with accessory Plant tank

116

1239

B
156 201 292 705 212 7

300

198

70 70 70

189

145 509 522

188 7

129

> HMW LT

WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION
-FRIEND
L

Y
RE F

Unit type IH Heat pump IP Reversible heat pump


(reversible on the refrigerant side)

Versions VB Base version Acoustic setting up AB Base setting up

Unit description
This series of water-water heat pumps satisfies the heating, cooling and domestic hot water production requirements of residential plants of small and medium size. All the units are suitable for indoor installation and can be applied to fan coil plants, radiant floor plants and high efficiency radiators plants. As source both water (from well, river, lake) or brine solutions (from geothermic probes) can be used. The control system allows to manage not only the refrigerant circuit but the whole plant with the possibility to choose different solutions both for the heating and cooling plant and for the domestic hot water management. The possibility of solar panels or other heating sources integration is also available. The heating function optimizes the flow water temperature according both to the ambient temperature and to the outdoor temperature through climatic curves adaptable to the building features. Its possible to manage a storage tank and two independent circuits (a direct one and a mixed one). The domestic hot water management allows to control the three way valve, the storage tank and the anti-legionella cycles (if necessary). The cooling function can be realized through passive cooling (free cooling), through active cooling (refrigerant circuit inversion) or through both systems actuated in sequence. When the unit is used in
Cod. BTP00563
130

radiant floor plants, to avoid condensate generation, a room humidity sensor can be installed. The internal programmer clock allows to define different daily switching programs for heating, cooling and domestic hot water production. The refrigerant circuit is equipped with scroll compressor mounted on damper supports, brazed plate heat exchangers, electronic expansion valve and reverse cycle valve (for reversible units). The circuit is protected by high and low pressure switches and flow switches on both the exchangers. The outdoor structure is thermally and acoustically insulated in order to reduce sound propagation and to allow the installation in domestic places. All the hydraulic pipes are thermally insulated to avoid condensate generation. All the units are supplied with phase sequence and voltage controller and with an outdoor temperature sensor in order to realize the climatic control. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

E IG

RA N T

Available range

Options
Plant side flow rate management not present standard pump high head pump modulating pump Soft starter not present standard

Accessories
Rubber vibration dampers Remote thermostat (wired or wireless) Remote control (wired or wireless) Wireless transmitter Wireless repeater Condensate sensor Room hygrostat Room humidity sensor Plant tank

Rev. 02

Data: Data: 04/02/2013

>

HMW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

CONTROL SYSTEM
The microprocessor controller is able to manage not only the unit itself but also all that components of the plant which allow to realize a complete system. The main functions of the control system are : room temperature control according temperature (climatic control) to the outdoor The unit controller is able to manage a lot of different plant solutions enabling automatically the necessary control algorythms according to the components which have been connected.

domestic hot water production (management of 3 way valve, storage tank, anti legionella cycles) management of a heating and/or cooling mixed circuit (pump and 3 way mixing valve) management of a heating direct circuit (only pump) management of a storage tank for heating and/or cooling management of electrical heaters for heating and domestic hot water (3 steps logic) solar panels integration passive cooling room humidity control for cooling with radiant systems internal programmer clock (for heating, cooling and domestic hot water) digital input for electrical energy low tariff alarm memory management and diagnostic compressor and pump operating hour counter possibility to manage more units in cascade (maximum 16)

20.5 C
Room temperature

18:28

Besides the standard user interface to be placed indoor, wired or wireless remote thermostats are available which allow to control all the operating parameters of the unit and to acquire the temperature in the different zones in order to realize a more precise and comfortable control.

The management of such components is possible through additional expansion modules which communicate with the unit by means of an internal bus and provide all the inputs and outputs required to fulfil a complete system.

The controller is able to manage up to two zones in heating (one by means of a mixed circuit and the other by means of a direct circuit) and one zone in cooling (by means of a mixed circuit). Its possible to realize more complex plants connecting to the heat pump controller further expansion modules in order to extend without limits the number of zones to be managed.

For each zone the following parameters can be set : set point daily or weekly operating time table climatic control curve room control sensor : it can be in common with the other zones or independent (in that case its necessary to install an additional room thermostat)

Cooling OPERATING LIMITS


Plant flow temperature Source return temperature (water) Source return temperature (brine)

Heating max
30 45 45

Unit type
-

min
6 5 -10

min
15 5 -10

max
60 25 25 C C C
131

> >

HMW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 30.1


Heating capacity Power input 28,2 5,13

35.1
32,4 5,93

40.1
38,2 7,01

45.1
42,7 7,90

50.1
48,1 8,86

55.1
56,4 10,5 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,50
4866 20 6655 36 21,6 5,02

5,46
5594 26 7670 47 24,9 5,76

5,45
6598 24 9031 43 29,4 6,84

5,41
7360 29 10089 53 32,9 7,64

5,43
8295 28 11378 51 37,0 8,57

5,37
9715 38 13368 70 43,4 10,1

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,30
3741 12 5326 25 30,5 5,18

4,32
4295 16 6134 32 34,9 5,97

4,30
5074 14 7231 30 41,2 7,07

4,31
5680 18 8122 37 46,0 7,95

4,32
6390 17 9140 36 51,8 8,90

4,30
7481 23 10744 48 60,6 10,6

l/h kPa l/h kPa kW kW

W30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

5,89
5276 23 6146 30 30,1 5,22

5,85
6052 30 7040 39 34,5 6,04

5,83
7138 28 8314 37 40,8 7,15

5,79
7983 34 9284 45 45,6 8,06

5,82
8983 33 10444 43 51,3 9,02

5,72
10518 44 12204 58 60,1 10,7

l/h kPa l/h kPa kW kW

B30W18

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

5,77
5207 22 6598 36

5,71
5983 29 7569 47

5,71
7069 27 8953 44

5,66
7897 33 9987 54

5,69
8897 32 11247 52

5,62
10431 43 13157 70

l/h kPa l/h kPa

IH W10W35

NOMINAL performances - Radiant plants Acoustic setting up : AB 30.1


Heating capacity Power input 28,8 5,20

35.1
33,0 6,02

40.1
39,0 7,11

45.1
43,6 8,02

50.1
49,1 8,99

55.1
57,6 10,7 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

5,54
4970 20 6813 37 22,1 5,09

5,48
5698 26 7825 48 25,4 5,84

5,49
6719 24 9211 45 30,0 6,92

5,44
7516 30 10326 56 33,6 7,74

5,46
8468 29 11641 54 37,8 8,68

5,38
9906 39 13657 73 44,2 10,2

l/h kPa l/h kPa kW kW

B0W35

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,34
3827 12 5469 26

4,35
4381 16 6274 34

4,34
5178 15 7400 31

4,34
5801 19 8323 39

4,35
6529 18 9369 37

4,33
7620 24 10970 50

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C
132

B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 =

source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C

>

HMW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

IP W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 30.1


Heating capacity Power input 26,0 6,14

35.1
29,8 7,05

40.1
35,1 8,35

45.1
39,3 9,34

50.1
44,3 10,50

55.1
51,9 12,3 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,23
4501 17 5709 27 20,1 5,97

4,23
5162 22 6567 35 23,2 6,82

4,20
6083 20 7716 32 27,3 8,10

4,21
6795 25 8642 40 30,6 9,01

4,22
7664 24 9757 38 34,4 10,1

4,22
8968 32 11464 52 40,3 11,8

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

3,37
3493 10 4530 18 23,2 5,13

3,40
4015 14 5233 24 26,6 5,87

3,37
4727 13 6134 22 31,4 6,96

3,40
5301 16 6916 27 35,2 7,77

3,41
5961 15 7779 26 39,6 8,71

3,42
6986 20 9163 36 46,2 10,2

l/h kPa l/h kPa kW kW

W30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Cooling capacity Power input

4,52
3999 14 4899 20 23,0 5,15

4,53
4582 18 5604 26 26,3 5,90

4,51
5406 16 6621 24 31,1 7,00

4,53
6058 20 7403 29 34,8 7,82

4,55
6813 19 8325 28 39,2 8,77

4,53
7963 26 9707 38 45,9 10,3

l/h kPa l/h kPa kW kW

B30W7

EER
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

4,47
3947 13 5263 24

4,46
4531 17 6029 31

4,44
5354 16 7132 29

4,45
5989 20 7963 35

4,47
6744 19 8964 34

4,46
7911 26 10483 46

l/h kPa l/h kPa

IH W10W45

NOMINAL performances - Standard plants Acoustic setting up : AB 30.1


Heating capacity Power input 26,5 6,21

35.1
30,4 7,14

40.1
35,9 8,47

45.1
40,2 9,47

50.1
45,2 10,7

55.1
52,9 12,5 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

4,27
4588 17 5835 28 20,6 6,04

4,26
5266 23 6718 36 23,6 6,90

4,24
6222 21 7919 34 27,9 8,19

4,24
6952 26 8874 42 31,2 9,12

4,22
7821 25 9977 40 35,1 10,2

4,23
9141 34 11721 54 41,0 12,0

l/h kPa l/h kPa kW kW

B0W45

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

3,41
3580 11 4670 19

3,42
4084 14 5338 25

3,41
4831 13 6299 23

3,42
5405 16 7079 29

3,44
6083 16 7969 28

3,42
7108 21 9353 37

l/h kPa l/h kPa

Data declared according to EN 14511. The values are referred to units without options or accessories. Brine = water with 30% ethylene glycol.
W10W65 = source: water in 10C out 7C / plant: water in 55C out 65C W10W55 = source: water in 10C out 7C / plant: water in 47C out 55C W10W45 = source: water in 10C out 7C / plant: water in 40C out 45C W10W35 = source: water in 10C out 7C / plant: water in 30C out 35C W30W7 = source: water in 30C out 35C / plant: water in 12C out 7C W30W18 = source: water in 30C out 35C / plant: water in 23C out 18C B0W65 = B0W55 = B0W45 = B0W35 = B30W7 = B30W18 = source: brine in 0C out -3C / plant: water in 55C out 65C source: brine in 0C out -3C / plant: water in 47C out 55C source: brine in 0C out -3C / plant: water in 40C out 45C source: brine in 0C out -3C / plant: water in 30C out 35C source: brine in 30C out 35C / plant: water in 12C out 7C source: brine in 30C out 35C / plant: water in 23C out 18C
133

> >

HMW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS WATER - WATER AND BRINE - WATER HEAT PUMPS FOR OUTDOOR OR INDOOR INSTALLATION

IP W10W55

NOMINAL performances - HIGH temperature and plants Acoustic setting up : AB 30.1 35.1
Heating capacity Power input 23,5 7,09 27,0 8,07

40.1
31,9 9,61

45.1
35,6 10,7

50.1
40,1 12,0

55.1
47,1 14,0 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,31
2561 6 4717 19 18,6 6,81

3,35
2942 7 5452 24 21,4 7,75

3,32
3476 7 6418 23 25,2 9,21

3,33
3879 9 7176 28 28,3 10,2

3,34
4369 8 8090 27 31,8 11,5

3,36
5121 11 9548 37 37,3 13,3

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,73
2027 4 3767 13

2,76
2332 5 4368 17

2,74
2746 4 5113 15

2,77
3084 6 5790 20

2,77
3465 5 6490 19

2,80
4064 7 7699 26

l/h kPa l/h kPa

IH W10W55

NOMINAL performances - HIGH temperature plants Acoustic setting up : AB 30.1 35.1


Heating capacity Power input 24,0 7,17 27,5 8,17

40.1
32,5 9,72

45.1
36,4 10,8

50.1
41,0 12,2

55.1
48,0 14,1 kW kW

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side Heating capacity Power input

3,35
2615 6 4840 20 19,1 6,89

3,37
2996 8 5569 25 21,8 7,83

3,34
3541 7 6561 24 25,8 9,32

3,37
3966 9 7376 29 28,9 10,3

3,36
4468 9 8319 28 32,5 11,6

3,40
5219 12 9777 39 38,0 13,4

l/h kPa l/h kPa kW kW

B0W55

COP
Water flow rate plant side Pressure drops plant side Water flow rate source side Pressure drops source side

2,77
2081 4 3904 14

2,78
2375 5 4470 18

2,77
2811 5 5272 16

2,81
3149 6 5949 21

2,80
3541 6 6681 20

2,84
4141 8 7890 27

l/h kPa l/h kPa

134

>

HMW LT

WATER-WATER AND BRINE-WATER HEAT PUMPS FORBRINE-WATER OUTDOOR OR INDOOR INSTALLATION WATER-WATER AND HEAT PUMPS

TECHNICAL DATA
Power supply Compressor type N compressors / N refrigerant circuits Plant side heat exchanger type Source side heat exchanger type Hydraulic fittings

30.1

35.1

40.1
scroll 1/1

45.1

50.1

55.1
V-ph-Hz n -

400-3N-50

stainless steel brazed plates stainless steel brazed plates 11/4 M

ACOUSTIC PERFORMANCES
Base acoustic setting up (AB)
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

30.1
65 51 40 34

35.1
66 52 41 35

40.1
67 53 42 36

45.1
68 54 43 37

50.1
69 55 44 38

55.1
70 56 45 39 dB(A) dB(A) dB(A) dB(A)

The acoustic performances are referred to units operating in cooling mode at nominal conditions W10W35. Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard. The sound pressure level is calculated according to ISO 3744 and is referred to a distance of 1/5/10 metres from the external surface of the unit.

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm

B
A

780

7 856

588 602

Unit with accessory Plant tank

B
A

1400

856

588 602

135

> HT - P
Available range
Versions VB Base Version

STORAGE TANKS FOR THE PLANT FOR OUTDOOR OR INDOOR INSTALLATION

(without charging heat exchanger)

Solar integration S0 Without coil

Unit description
This series of storage tanks allows to increase the thermal inertia of the plant and to guarantee a higher stability of the water sent to the hydronic distribution circuits. All the units are suitable both for outdoor or indoor installation and can be applied to residential plants of small and medium size. Each tank is equipped with four hydraulic fittings in order to be configured both as tank in the flow or as primary - secondary tank. A fitting for the installation of an integrative electrical heater (accessory) is also available. The tank is equipped with an automatic air vent and a discharge tap and is properly insulated in order to reduce thermal losses and avoid condensate generation during cooling operating mode. All the units are supplied with a temperature probe fitted in a dedicated well inside the tank and to be connected to the heat pump control system in order to enable the control algorithms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Rubber vibration dampers Integrative electrical heater

HYDRAULIC CONNECTION CONFIGURATION


Tank in the flow The tank allows to increase the thermal inertia of the system. The distribution circuits must be designed taking into account the minimum water flow rate to be guaranteed through the heat pump and the required available static heads. The heat pump control is based on the return temperature which is steadily monitored keeping always running the heat pump circulation pump. Primary - secondary tank The tank, besides increasing the thermal inertia of the system, operates also as hydraulic separator allowing an optimized management of the distribution circuits of the plant. The heat pump control is based on the tank temperature and the heat pump circulation pump is activated only when necessary.

1
HEAT PUMP

3
PLANT HEAT PUMP

3
PLANT

Cod. BTP00575
136

Rev. 00

Data: 12/06/2012

>

HT - P

STORAGE TANKS FOR THE PLANT FOR OUTDOOR OR INDOOR INSTALLATION STORAGE

TANKS

TECHNICAL DATA
Storage tank volume Insulation Weight Weight in operation Max pressure Max temperature Hydraulic fittings Integrative electrical heater fitting

40
40 10 52 92 10 95 1 M 11/4 F

90
90 10 72 162 10 95 1 M 11/4 F

140
140 10 92 232 10 95 11/4 M 11/4 F l mm kg kg bar C -

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm

40
L B H L1 L2 L3 H1 705 377 420 201 292 212 145

90
705 522 570 201 292 212 300

140
855 602 620 236 350 269 350 mm mm mm mm mm mm mm

B
A

1 2

3 4
120 H1 H

L1 25

L2 L

L3

145 B

1 2 3 4

Tank in the flow Heat pump flow Plant flow -

Primary - secondary tank Heat pump flow Heat pump return Plant flow Plant return

39

137

> HT - P 300

STORAGE TANKS FOR THE PLANT FOR INDOOR INSTALLATION

Available range
Versions VB Base version Solar integration S0 Without coil S1 With coil

Unit description
This series of storage tanks allows to increase the thermal inertia of the plant and to guarantee a higher stability of the water sent to the hydronic distribution circuits. All the units are suitable both for indoor installation and can be applied to residential plants of small and medium size. Each tank is equipped with four hydraulic fittings in order to be configured both as tank in the flow or as primary - secondary tank. A fitting for the installation of an integrative electrical heater (accessory) is also available. The tank is equipped with an automatic air vent, an expansion vessel, a safety valve and a discharge tap and is properly insulated in order to reduce thermal losses and avoid condensate generation during cooling operating mode. The tank can also be equipped with a coil for solar integration. All the units are supplied with a temperature probe fitted in a dedicated well inside the tank and to be connected to the heat pump control system in order to enable the control algorithms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Integrative electrical heater

TECHNICAL DATA
Storage tank volume Insulation Max pressure Solar integration coil surface Expansion vessel volume Max temperature Integrative electrical heater fitting Weight Weight in operation Heat pump nominal MAXIMUM capacity 280 50 6 1,2 4 95 11/4 F 140 420 20 l mm bar m2 l C kg kg kW

Cod. BTP00591
138

Rev. 00

Data: 03/09/2012

>

HT - P 300

STORAGE TANKS FOR THE PLANT FOR INDOOR INSTALLATION STORAGE

TANKS

HYDRAULIC CONNECTION CONFIGURATION


Tank in the flow The tank allows to increase the thermal inertia of the system. The distribution circuits must be designed taking into account the minimum water flow rate to be guaranteed through the heat pump and the required available static heads. The heat pump control is based on the return temperature which is steadily monitored keeping always running the heat pump circulation pump.
Heat pump Solar Plant

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
B

Primary - secondary tank The tank, besides increasing the thermal inertia of the system, operates also as hydraulic separator allowing an optimized management of the distribution circuits of the plant. The heat pump control is based on the tank temperature and the heat pump circulation pump is activated only when necessary.
Heat pump Solar Plant

1994

90 90 80 80 45

260
52 93 52 600
139

135

2 3

1 6 5 4

600

1 2 3 4 5 6

Tank in the flow Heat pump flow Solar panel outlet Solar panel inlet Plant flow -

Primary - secondary tank Heat pump return Heat pump flow Solar panel outlet Solar panel inlet Plant flow Plant return

2030

1 M 1 M 18 mm 18 mm 1 M 1 M

> HT - P 500

STORAGE TANKS FOR THE PLANT FOR INDOOR INSTALLATION

Available range
Versions VB Base version Solar integration S0 Without coil S1 With coil

Unit description
This series of storage tanks allows to increase the thermal inertia of the plant and to guarantee a higher stability of the water sent to the hydronic distribution circuits. All the units are suitable both for indoor installation and can be applied to residential plants of small and medium size. Each tank is equipped with four hydraulic fittings in order to be configured both as tank in the flow or as primary - secondary tank. A fitting for the installation of an integrative electrical heater (accessory) is also available. The tank is equipped with an automatic air vent, an expansion vessel, a safety valve and a discharge tap and is properly insulated in order to reduce thermal losses and avoid condensate generation during cooling operating mode. The tank can also be equipped with a coil for solar integration. All the units are supplied with a temperature probe fitted in a dedicated well inside the tank and to be connected to the heat pump control system in order to enable the control algorithms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Integrative electrical heater

TECHNICAL DATA
Storage tank volume Insulation Max pressure Solar integration coil surface Expansion vessel volume Max temperature Integrative electrical heater fitting Weight Weight in operation Heat pump nominal MAXIMUM capacity 500 50 6 1,2 4 95 11/4 F 230 740 45 l mm bar m2 l C kg kg kW

Cod. BTP00589
140

Rev. 00

Data: 03/09/2012

>

HT - P 500

STORAGE TANKS FOR THE PLANT FOR INDOOR INSTALLATION STORAGE

TANKS

HYDRAULIC CONNECTION CONFIGURATION


Tank in the flow The tank allows to increase the thermal inertia of the system. The distribution circuits must be designed taking into account the minimum water flow rate to be guaranteed through the heat pump and the required available static heads. The heat pump control is based on the return temperature which is steadily monitored keeping always running the heat pump circulation pump.
Heat pump Solar Plant

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
B

1 2 3 4 5 6

Primary - secondary tank The tank, besides increasing the thermal inertia of the system, operates also as hydraulic separator allowing an optimized management of the distribution circuits of the plant. The heat pump control is based on the tank temperature and the heat pump circulation pump is activated only when necessary.
Heat pump Solar Plant

96 88 80 78 80 88 96 88 80 78 80 88

272 272 59 59

2000 780 780

2000

88

88 780 780

1 2 3 4 5 6

Tank in the flow Heat pump flow Solar panel outlet Solar panel inlet Plant flow -

Primary - secondary tank Heat pump return Heat pump flow Solar panel outlet Solar panel inlet Plant flow Plant return

11/4 M 11/4 M 18 mm 18 mm 11/4 M 11/4 M


141

> HT - D 300
Available range
Versions VB Base version V1 Primary heat exchanger version V2 Secondary heat exchanger version (instantaneous DHW production) Solar integration S0 Without coil S1 With coil

STORAGE TANKS FOR DOMESTIC HOT WATER PRODUCTION FOR INDOOR INSTALLATION

Unit description
This series of storage tanks allows to storage the thermal energy requested to satisfy the domestic hot water requirements. All the units are suitable for indoor installation and can be applied to residential heating and cooling plants of small and medium size. In the base version (VB) the tank charge is realized heating the sanitary water outside the unit. The tank is filled with sanitary hot water and is equipped with automatic air vent, expansion vessel, safety valve and discharge tap. In the primary heat exchanger version (V1) the tank charge is realized by means of a plate heat exchanger, placed before the tank, and of a glandless pump suitable for domestic hot water. The tank is filled with sanitary hot water and is equipped with automatic air vent, expansion vessel, safety valve and discharge tap. In the secondary heat exchanger version (V2) the tank is filled with technical water that is used to produce domestic TECHNICAL DATA
Storage tank volume Insulation Max pressure Solar integration coil surface Expansion vessel volume Max temperature Integrative electrical heater fitting Weight Weight in operation Heat pump nominal MAXIMUM capacity 280 50 6 1,2 4 95 11/4 F 150 430 20 Cod. BTP00583
142

hot water instantaneously by means of a plate heat exchanger, placed after the tank, and a glandless pump activated by a flow switch that detects the domestic hot water request. The tank is equipped with automatic air vent, expansion vessel, safety valve, magnesium anode and discharge tap. Each tank is properly insulated in order to reduce thermal losses and is equipped with a fitting for the installation of an integrative electrical heater (accessory). The tank can also be equipped with a coil for solar integration. All the units are supplied with a temperature probe fitted in a dedicated well inside the tank.

The management of all the components contained inside the unit is realized by means of integrated control modules, to be connected to the heat pump control system in order to enable the control algorithms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Integrative electrical heater

l mm bar m2 l C kg kg kW Rev. 00 Data: 05/09/2012

>

HT - D 300

STORAGE TANKS FOR DOMESTIC HOT WATER PRODUCTIONSTORAGE

TANKS

HYDRAULIC CONNECTION CONFIGURATION


VB - Base version
Charge Solar DHW

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
B

V1 - Primary heat exchanger version


Charge Solar DHW

V2 - Secondary heat exchanger version


Charge Solar DHW 45

1994

90 90 80 80

260
52 93 600
143

135

2 1 2 3 4 7 8 3

1 8 7
52

FS

600

1 2 3 4 7 8

Charge outlet Charge inlet Solar panel outlet Solar panel inlet Domestic hot water outlet Domestic cold water inlet

2030

1 M 1 M 18 mm 18 mm 1 M 1 M

> HT - D 500
Available range
Versions VB Base version V1 Primary heat exchanger version V2 Secondary heat exchanger version (instantaneous DHW production) Solar integration S0 Without coil S1 With coil

STORAGE TANKS FOR DOMESTIC HOT WATER PRODUCTION FOR INDOOR INSTALLATION

Unit description
This series of storage tanks allows to storage the thermal energy requested to satisfy the domestic hot water requirements. All the units are suitable for indoor installation and can be applied to residential heating and cooling plants of small and medium size. In the base version (VB) the tank charge is realized heating the sanitary water outside the unit. The tank is filled with sanitary hot water and is equipped with automatic air vent, expansion vessel, safety valve and discharge tap. In the primary heat exchanger version (V1) the tank charge is realized by means of a plate heat exchanger, placed before the tank, and of a glandless pump suitable for domestic hot water. The tank is filled with sanitary hot water and is equipped with automatic air vent, expansion vessel, safety valve and discharge tap. In the secondary heat exchanger version (V2) the tank is filled with technical water that is used to produce domestic TECHNICAL DATA
Storage tank volume Insulation Max pressure Solar integration coil surface Expansion vessel volume Max temperature Integrative electrical heater fitting Weight Weight in operation Heat pump nominal MAXIMUM capacity 500 50 6 1,2 4 95 11/4 F 250 760 45 Cod. BTP00585
144

hot water instantaneously by means of a plate heat exchanger, placed after the tank, and a glandless pump activated by a flow switch that detects the domestic hot water request. The tank is equipped with automatic air vent, expansion vessel, safety valve, magnesium anode and discharge tap. Each tank is properly insulated in order to reduce thermal losses and is equipped with a fitting for the installation of an integrative electrical heater (accessory). The tank can also be equipped with a coil for solar integration. All the units are supplied with a temperature probe fitted in a dedicated well inside the tank.

The management of all the components contained inside the unit is realized by means of integrated control modules, to be connected to the heat pump control system in order to enable the control algorithms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Integrative electrical heater

l mm bar m2 l C kg kg kW Rev. 00 Data: 19/07/2012

>

HT - D 500

STORAGE TANKS FOR DOMESTIC HOT WATER PRODUCTIONSTORAGE

TANKS

HYDRAULIC CONNECTION CONFIGURATION


VB - Base version
Charge Solar DHW

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B 600 mm 600 mm
B

V1 - Primary heat exchanger version


Charge Solar DHW

1 2 3 4 7 8

Charge outlet Charge inlet Solar panel outlet Solar panel inlet Domestic hot water outlet Domestic cold water inlet
1 2 3 4 7 8
88

11/4 M 11/4 M 18 mm 18 mm 1 M 1 M

V2 - Secondary heat exchanger version


Charge Solar DHW

FS

96 88 80 78 96 88 80 78

256 256

88 96 88 96 59 59

2000 780 780 780 780

2000

88

145

> HT - M
Available range

STORAGE TANKS FOR THE PLANT AND FOR DOMESTIC HOT WATER PRODUCTION FOR INDOOR INSTALLATION
of a plate heat exchanger, placed before the tank, and of a glandless pump suitable for domestic hot water. The tank is filled with sanitary hot water and is equipped with automatic air vent, expansion vessel, safety valve, magnesium anode and discharge tap. In the secondary heat exchanger version (V2) the tank is filled with technical water that is used to produce domestic hot water instantaneously by means of a plate heat exchanger, placed after the tank, and a glandless pump activated by a flow switch that detects the domestic hot water request. The tank is equipped with automatic air vent, expansion vessel, safety valve and discharge tap. Each tank is properly insulated in order to reduce thermal losses and avoid condensate generation during cooling operating mode. A fitting for the installation of an integrative electrical heater (accessory) is also available on each tank. The tanks can also be equipped with coils for solar integration both on the domestic hot water tank and on the plant tank (in this case a 3 way valve to divert the water flow is also present). The unit is equipped with 3 way valve to divert the water flow from the plant tank to the domestic hot water tank and with the temperature probes on both the tanks (fitted in dedicated wells). The management of all the components contained inside the unit is realized by means of integrated control modules, to be connected to the heat pump control system in order to enable the control algoriPlant tank
200 50 6 0,7 95 11/4 F 290 805 45 Cod. BTP00577 Rev. 01

Versions V1 Primary heat exchanger version V2 Secondary heat exchanger version (instantaneous DHW production) Solar integration S0 Without coil S1 With coil on the domestic hot water tank S2 With coil on the domestic hot water tank and on the plant tank

Unit description
Each unit is equipped with two independent storage tanks : one for the plant and one for the domestic hot water production. All the units are suitable for indoor installation and can be applied to residential heating and cooling plants of small and medium size. The tank for the plant allows to increase the thermal inertia of the plant and to guarantee a higher stability of the water sent to the hydronic distribution circuits. The tank is configured as primary - secondary tank and is equipped with automatic air vent, safety valve and discharge tap. The tank for the domestic hot water production allows to storage the thermal energy requested to satisfy the domestic hot water requirements. In the primary heat exchanger version (V1) the tank charge is realized by means TECHNICAL DATA
Storage tank volume Insulation Max pressure Solar integration coil surface Expansion vessel volume Max temperature Integrative electrical heater fitting Weight Weight in operation Heat pump nominal MAXIMUM capacity

thms implemented to optimize the management of the tank and of the circulation pumps. All the units are accurately built and individually tested in the factory. Only electric and hydraulic connections are required for installation.

Accessories
Integrative electrical heater

Domestic hot water tank


300 50 6 1,2 4 95 11/4 F l mm bar m2 l C kg kg kW Data: 04/02/2013

146

>

HT - M

STORAGE TANKS FOR THE PLANT AND FOR DOMESTIC HOT WATER PRODUCTION STORAGE

TANKS

HYDRAULIC CONNECTION CONFIGURATION


V1 - Primary heat exchanger version
Charge Solar Plant DHW

V2 - Secondary heat exchanger version


Charge Solar Plant DHW

FS

DHW
88

DHW

DIMENSIONS AND MINIMUM OPERATING AREA


Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations. A B
B

600 mm 600 mm
1 2 3 4 5 6 7 8

96 88 80 78 80 88 88 88 96
88 59

2225

PLANT

PLANT

780
2225

1 2 3 4 5 6 7 8

Charge outlet Charge inlet Solar panel outlet Solar panel inlet Plant outlet Plant inlet Domestic hot water outlet Domestic cold water inlet

11/4 M 11/4 M 18 mm 18 mm 11/4 M 11/4 M 1 M 1 M


147

780

96 88 80 78 80 88 88 88 96

> HT - 1
Available range

STORAGE TANK WITH AIR-WATER HEAT PUMP FOR DOMESTIC HOT WATER PRODUCTION FOR INDOOR INSTALLATION
C
O

-FRIEND
L
Y

Versions VA Version with storage tank for domestic hot water Solar integration S1 With coil

RE F

Unit description
This series of air-water heat pumps satisfies the domestic hot water production requirements of small residential plants. All the units are suitable for indoor floor standing installation and are equipped with a stainless steel storage tank containing domestic hot water which is kept at the desired temperature (up to maximum 60C) extracting heat from the outdoor air by means of the heat pump integrated inside the unit. The inlet and outlet air ducts can be configured in various ways in order to fit the different installation needs and to recover the available energy coming from other rooms inside the building. The domestic hot water contained inside the storage tank is heated by means of an OPERATING LIMITS
Outdoor air temperature DHW temperature in the tank

aluminium coil wounded around the storage tank in order to guarantee a double wall insulation between the refrigerant gas and the domestic hot water. The storage tank is equipped with safety valve and magnesium anode and is properly insulated in order to reduce thermal losses Inside the storage tank is also installed an electrical heater to integrate the heating power supplied by the heat pump, that in any case can work without any problem up to outdoor air temperature of 0C by means of hot gas injection defrosting cycles. The tank is furthermore equipped with a stainless steel coil for solar integration, managed by the unit controller. min
-30 10

AERAULIC CONNECTIONS CONFIGURATION


Use of energy available in the installation room Use of energy available outdoor Use of energy available in a near room Use of energy available in different rooms

AERAULIC performances
Air flow rate max / min Ducts diameter Maximum overall ducts lenght
148

200
350 / 150 150 8

E IG

RA N T

The management of the unit is performed by means of a microprocessor controller with a LCD touch screen display. All the units are accurately built and individually tested in the factory. Only electric, aeraulic and hydraulic connections are required for installation.

max
43 60 C C

250
350 / 150 150 8 Cod. BTP00601

300
350 / 150 150 8 Rev. 01 m3/h mm m Data: 19/10/2012

>

HT - 1

STORAGE TANK WITH HEAT FOR PUMP FOR DHW PRODUCTION STORAGE TANKS DOMESTIC HOT WATER

with HEAT PUMP


300
V-ph-Hz W l m2 kg kg

TECHNICAL DATA
Power supply Type of compressor Type of fan Electrical integrative heater power Storage tank volume Solar integration coil surface Weight Operating weight

200

250
230 - 1 - 50 rotary centrifugal 1500 250 1,5 86 336

200 1,0 82 282

300 2,0 94 394

Performances EN 16147
1 2 3 4 Heating up time : th Heating up energy input : Weh Stand by power input : Pes Class of reference tapping cycle Energy input during the cycle : WEL-TC Efficiency during the cycle : COPDHW Reference hot water temperature : WH Maximum quantity of usable hot water : Vmax

200
5 : 20 2,40 35

250
7 : 30 3,32 38

300
9 : 00 3,98 40 hh : mm kWh W

L
4,40

L
4,43

L
4,46

kWh C m3 kW kW -

2,65
55 0,254

2,63
55 0,318

2,61
55 0,381

Performances EN 255-3
5 Heating capacity Power input

200
1,80 0,46

250
1,80 0,46

300
1,80 0,46

COP
1 2 5

3,91

3,91

3,91

Heating up cycle : air inlet 15C d.b. 12C w.b. / starting temperature of the water in the tank 10C Stand by : air inlet 15C d.b. 12C w.b. Air inlet 15C d.b. 12C w.b. / temperature of the water in the tank : in 15C out 55C

ACOUSTIC performances
Sound power level Sound pressure level at 1 metre Sound pressure level at 5 metres Sound pressure level at 10 metres

200
61 45 35 29

250
61 45 35 29

300
61 45 35 29 dB(A) dB(A) dB(A) dB(A)

Unit placed in free field on reflecting surface (directional factor equal to 2). The sound power level is measured according to ISO 3744 standard.

DIMENSIONS AND MINIMUM OPERATING AREA

8 1

1 2 3 4 5 6 7 8

Domestic hot water outlet Domestic cold water inlet Domestic hot water recirculation Solar integration outlet Solar integration inlet Storage tank discharge Condensate discharge (defrost cycles) Safety valve fitting

3/4 F 3/4 F 3/4 F 3/4 F 3/4 F 3/4 F 1/2 F 3/4 F

660

660

2 6

Respect the free area around the unit as shown in figure in order to guarantee a good accessibility and facilitate maintenance and control operations.

0,6 m

0,6 m

0,6 m

0,1 m

7 4-5
4

200
A B C 560 1041 1705

250
560 1297 1950

300
640 1135 1800 mm mm mm
149

45

NOTE

150

NOTE

151

Ferroli spa

37047 San Bonifacio (VR) Italy Via Ritonda 78/A tel. +39.045.6139411 fax +39.045.6103595 www.ferroli.it

Cod. 3QE37111 - edition 03.2013