For over 70 years, Canadian electrical contractors, plant engineers and engineering consultants have placed their trust

in Thomas & Betts electrical components. Today, Thomas & Betts Ltd. offers a complete package of market-driven products and services designed to give you the power to succeed in today's economy.

THE POWER OF T&B ENGINEERED PRODUCTS AND SERVICES


Our products and services continue to set new standards for quality, reliability and innovation.

Highly-focused sales, product support and customer


service team dedicated to serving the industrial MRO and OEM markets

Guaranteed, competitive pricing The broadest offering of field-proven, brand name


products available from one manufacturer

One order, one shipment for thousands of standard


products through Thomas & Betts and your Signature Service distributor

Reduced lead time on critical products through your


Signature Service distributor

Technical support via phone, fax on demand


and the internet

T&B Access provides instant access to electrical


distributors, the answers they need at anytime

ISO-certified manufacturing Quality engineering and manufacturing Local and national inventory support T&B Tool Lease program - the tools you need today
without tomorrow's investment

THE POWER OF CHOICE


As North America's largest single source for electrical components, Thomas & Betts is powered by the longest and most complete list of reputable brand name products available from one manufacturer in the industry today. With services like "one order, one shipment" available through your Thomas & Betts distributor, the more T&B purchases you make, the more you can save. To request information about any of these products contact your Regional Sales Office.

All-Struct Amerace Battpac Blackburn Blackburn Color-Keyed Elastimold Emergi-Lite ExpressTray E-Z-Code E Z Ground Furseweld Hazlux Iberville Iberville Lumacell Marrette Meyer Microlectric Mipco Nutek Ocal Partex Pos-E-Kon Power Solutions-Industrial Ready-Lite RedDot Reznor Russellstoll Safe-Ty Shield-Kon Shrink-Kon Sta-Kon StarTeck Steel City Superstrut Sure-Ty T&B T&B Ty-Duct Ty-Fast Ty-Rap

Aluminum and steel structures Airfield lighting Battery-powered and compression tools Compression connectors Grounding products Compression connectors Premolded connectors for underground distribution applications Emergency lighting systems Wire-mesh cable management system Wire marker systems Compression connectors Exothermic connectors Hazardous location lighting Roughing-in products Steel boxes and covers Emergency lighting systems Wire connectors Transmission and light duty engineered steel poles Meter sockets and pole line hardware Plugs, receptacles, modules power outlets and connectors Nonmetallic boxes Coated products Wire marker systems Industrial connectors Power quality Emergency lighting systems Weatherproof boxes and covers Heating, ventilation and cooling systems Plugs, receptacles and connectors Low profile in-line fasteners Grounding connectors and tools Insulation products Terminals and application tools Fittings for teck cable Floor boxes, access modules and poke throughs Metal framing, channel and accessories Automated fastening system Cable tray systems Conduit fittings Wiring duct One-piece ties and accessories Cable ties

Every effort is made to ensure the accuracy of the information contained in this catalogue at the time of publication. As part of our ongoing quality control program, we actively encourage customer input. Should you have any comments regarding the content of our catalogues, please forward them via e-mail to mrkt_canada@tnb.com or contact your Thomas & Betts sales representative.

Table of Contents

The Whole Family Star Teck Extreme Director TM (STED) Teck Cable Fittings Specifications Hazardous Locations C.E.C. Classifications Hazardous Locations Class, Zone and Division Certifications Quick Reference Star Teck (ST) Series Fittings for Teck and ACWU Cable Star Teck XP (STX) Series Fittings for Teck Cable Star Teck Extreme (STE) Series Fittings for Teck and ACWU Cable Bond Star Grounding Locknut

4 5 67

8 11

12 13

14 15

16 17

18 19 20 21

Star Teck Extreme Director TM (STED) New! Cable Fittings 22 23 Star Teck Extreme XP (STEX) Series Fittings for Teck Cable

24 25

10464 Series Watertight Fittings / ACWU


90 Watertight Fittings and Non Watertight Fittings Silver Grip Liquidtight Fittings for Tray Cable Silver Grip TCF Series Accessories Alphanumeric Index

26

27

28 29 30 31 32

The Whole Family

1988 - STAR TECK (ST Series) Fittings


A natural extension of the 10464 Series, the rst STAR TECK cable tting incorporated input from end-users in Canadian industry and was the rst teck tting to use a pop-on design requiring no disassembly. Other unique features included a splined gland and gripping features. The original STAR TECK tting for teck and ACWU cable set the standard for ease of installation, quality engineering and safe, reliable terminations in challenging industrial environments.

STAR TECK Cable Fittings A tradition of industry rsts.


A pioneer in the design and manufacture of teck cable ttings, the Thomas & Betts STAR TECK product line remains an indisputable industry standard to this day. Since the introduction of the 10464 tting in 1953, Thomas & Betts engineers have gathered feedback from end-users working in the harshost and most corrosive industrial environments to bring you the STAR TECK line of high performance teck cable ttings which, year after year, remain the industry benchmark for safety, quality construction and ease of installation. Designed and manufactured in Canada to meet the unique challenges of Canadian industry, the STAR TECK cable ttings line continues to evolve, keeping pace with technological advances whilst improving performance and installation efciency.

1990 - STAR TECK XP (STX Series) Fittings

Working with engineers from the Canadian petrochemical, oil and gas industries, Thomas & Betts then introduced the STAR TECK XP tting. With an easy-to-ll, integral sealing chamber and a disconnectable design requiring minimal cable prepatation, this tting became the benchmark for ease of installation in hazardous environments. A line of liquid and putty sealants was also developed at the same time, eliminating the need for the cement sealants used up to this point.

1997 - STAR TECK EXTREME (STE Series) Fittings


The STAR TECK EXTREME tting was the industrys rst range-taking teck tting. This tting simplied matching cables to ttings and reduced the number of different size ttings that had to be inventoried. Now one STAR TECK EXTREME tting could cover the range of three conventional STAR TECK tting hub sizes. With the STAR TECK EXTREME tting also came the invention of removable armour stops, another feature that has since become an industry standard.

1998 - STAR TECK EXTREME XP (STEX Series) Fittings


With the introduction of STAR TECK EXTREME XP tting, Thomas & Betts combined the ease of installation of the original STAR TECK XP tting with all of the unique benets of STAR TECK EXTREME range-taking ttings. End-users in hazardous, explosion-proof environments could now benet from simplied sitting selection, reduced inventory and removable armour stops.

2000 - BOND STAR Grounding Locknut


In response to the increased use of microprocessors, controllers, instrumentation and data communications in demanding industrial environments. Thomas & Betts introduced to BOND STAR grounding locknut for use in data and control applications sensitive to oating voltage differences.

Detailed technical specications and ordering information are available online at www.tnb.ca or through your local Thomas & Betts sales representative.

Star Teck Extreme Director TM (STED) Teck Cable Fittings

New!

Specications
Teck Cable

Teck cable derived its name from one of its first users, the Teck-Hughes Gold Mines in Kirkland Lake, Ontario. Teck 90 is CSA Type designation. Trade designation of this cable is Armored Cable. Teck cables up to 5,000 volts working potential are manufactured in accordance with CSA Standard C22.2 No. 131 and are provided with a bare ground conductor and an optional outer jacket. Depending on phase conductor insulation, the cables are designated as Teck 90 (X-LINK) when insulation is cross-linked polyethylene and Teck 90 (EP) when insulation is ethylene propylene. Both cables are rated for 90C service (dry location) and 75C (wet locations). Teck cable suitable for installation down to minus 40 is marked Teck 90 (X-LINK) minus 40 or Teck 90 (EP) minus 40. Over 5,000 volts working potential Teck cables are manufactured in accordance with IPCEA standards and are certified by CSA. Cables are provided with or without ground wire as required. Teck cables with outer jacket may be used for exposed or concealed wiring in wet or dry locations, indoors/outdoors and in corrosive environments. Teck cables are suitable for use in ventilated, non-ventilated and ladder type cable

troughs, in ventilated flexible cable ways in both dry and wet locations. Teck cable with outer jacket is suitable for direct earth burial and for Class II Division 2, Class III, Divisions 1 and 2 hazardous locations per Canadian Electric Code. Some of the features of Teck cable are its flexibility and ease of installation. Absence of dead air space within cable increases heat transfer and minimizes condensation. Overall protective covering provides good environmental protection. Bend radius for permanent training during installation usually varies between 7 to 12 times the cable diameter depending on cable construction and manufacturers recommendations. Larger radius bends are required for other conditions. Section 12-3028 of the Canadian Electric Code requires that the terminating fittings used must provide adequate strain relief to terminal connections and ensure electrical continuity without injury to non-metallic sheath. Continuity is mandatory whether or not the armor is used as a grounding conductor. Except for dry locations free from corrosive atmosphere, the non-metallic jacket is not permitted to be stripped back to a point where armor is

exposed after installation. Where single conductor cables carrying 200 amps or more enter metal boxes through separate openings, certain precautions are required to prevent overheating of the metal by induction. Use of non-ferrous or non-metallic box connectors, locknuts and bushings and installation of non-magnetic panel inserts is suggested in the code. Please refer to the following for further details and complete information: 1. CEC Section 12Wiring Methods CEC Section 4Conductors 2. CSA C22.2 No. 131... Safety Standard for Type Teck Cable 3. CSA C22.2 No. 18.1Safety Standards for Outlet Boxes 4. CSA C22.2 No. 18.3Safety Standards for Conduit, Tubing and Cable Fittings

Please note The excerpts and other material herein, whether relating to the National Electrical Code, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, are not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product.

CSA Certified CSA Certified for use in hazardous locations of class I, II, III. Suitable for locations of class I C US with a class I certified anti-explosion firewall. cCSAus Certified for use in hazardous locations; i.e. e II, Class I, Zone I, AEx e II compliant with C.C.C. and N.E.C.

Specications
Metal-Clad Cable and Aluminum-Sheathed Cable

Metal Clad Cable Type MC is a factory assembly of one or more conductors, each individually insulated and enclosed in a metallic sheath of interlocking tape, or a smooth or corrugated tube. Metal Clad Cable Type MC is rated for use up to 5,000 volts. The National Electrical Code permits use of metallic sheath as an equipment grounding conductor. Metal Clad Cables are available with a variety of phase conductor insulations such as crosslinked polyethylene, and silicone rubber ethylene propylene, depending on rated temperature of conductors and working potential. Metallic sheath can be of galvanized steel, aluminum, copper or bronze. A special outer covering such as PVC or Neoprene over metallic sheath is usually provided for environmental protection. Metal clad cable is not permitted in locations where it could be subject to physical damage. Metal clad cable can be used exposed, concealed, in cable tray, in any approved raceway, and, with minor exceptions, in hazardous locations. Type MC cable can also be used for services, feeders, branch circuits, power, lighting, control and signal circuits. Use of metal clad cable is permitted in wet locations, or where exposed to destructive corrosive conditions or directly buried in earth,

concrete or exposed to cinder fills, strong chlorides, caustic alkalis, vapors, chlorine or hydrochloric acids provided the construction of cable, the conductors within the metallic sheath, the metallic sheath and protective cover over metallic sheath comply with requirements enumerated in Sec. 334-3 of the National Electrical Code. Bend radius restrictions are dependent on the size of the cable and the type of sheath, i.e. smooth, interlocked armor, corrugated sheath or shielded conductors and varies from 7 to 15 times cable external diameter. NEC Article 330 requires that approved fittings be used for termination. Where single-conductor cables carrying alternating current enter a ferrous metal box or enclosure, procedures described in NEC Section 300-20 must be followed to reduce effects of heating due to induced currents. These procedures include recommended arrangements of conductors, cutting of slots in metal between individual conductor holes, passing of conductors through insulating walls, or use of non-magnetic aluminum sheathed cable and aluminum terminating fittings. Portions of this section reprinted by permission from NFPA 70 Electrical Code, Copyright National Fire Protection Association, Boston, MA.

Please refer to the following for further details and complete information: 1. NEC Article 330Metal Clad Cable (Type MC) 2. U.L. 4, ANSI C33.9Safety Standards for Type MC Metal Clad Cable 3. ANSI C33.84Safety Standards for Outlet Boxes and Fittings 4. W-F-406Federal Specification. Fittings for Cable, Power Electrical and Conduit Metal, Flexible 5. NEMA FM-1Standards Publication. Fittings and Supports for Conduit and Cable Assemblies 6. UL514ASafety Standards for Metallic Outlet Boxes 7. UL514CSafety Standards for Conduit, Tubing and Cable Fittings

Hazardous Locations C.E.C. Classications


C.E.C. Code Changes
In 1998, the Canadian Electrical Code (C.E.C.) adopted the International Electrotechnical Commission's (IEC) Three Zone Area Classification System for Class I hazardous locations. The Zone System is an alternate classification for Class I hazardous locations and was adopted to promote harmonization with international standards. The Division System for Class I hazardous locations continues to be used for existing facilities and is expected to remain in use at least for the next few editions of the C.E.C. For this reason, this catalogue's certification information for Class I hazardous locations includes both the pre-1998 Division System and the new I.E.C. Zone System. The following pages provide an overview of C.E.C. hazardous location classifications.

Classes
The Canadian Electrical Code (C.E.C.), Part I, Section 18 - Hazardous Locations, identifies three classes of hazardous locations: Class I - Gas and Vapour Environments Class II - Dust Environments Class III -Fibers and Flyings Environments The 1998 revisions to the C.E.C. affect only Class I - Gas and Vapour Environments. Hazardous location is defined by the C.E.C. as premises, buildings or parts thereof in which there exists the hazard of fire or explosion due to highly flammable gases and/or flammable, volatile liquid mixtures that are manufactured, used or stored in other than the original containers. This definition can include combustible dust and easily ignitable fibers that are likely to be present in sufficient quantities to produce an explosive mixture.

The following abbreviations are used in this catalogue: HLA Hazardous Location Area OLA Ordinary Location Area

Class I Gas and Vapour Environments


Locations are deemed hazardous due to the presence of gases or vapours present in the air in sufficient quantity to produce explosive or ignitable mixtures. Locations identified as Class I require that enclosures and connectors be explosion proof. Class I hazardous locations are further subdivided into : Divisions (pre-1998 version of the C.E.C.), or Zones (I.E.C. Classification - 1998 C.E.C.) The Division System may still be used for the maintenance and repair of existing facilities. All new construction must use the I.E.C. Zone Classification. Divisions Division 1 a Class I location where the hazardous atmosphere is expected to be present during normal operations on a continuous, intermittent or periodic basis. Division 2 a Class I location where volatile flammable liquids or gases are handled, processed or used but in which they would normally be confined within closed containers or closed systems from which they can escape only in the event of an accidental rupture or breakdown of the containers or systems.

Area Classification Divisions vs. Zones


Continuous Hazard Intermittent Hazard Hazard Under Abnormal Conditions

Zone 0 Division 1

Zone 1

Zone 2 Division 2

Hazardous Locations C.E.C. Classications


Class I (continued)
Zones Zone 0 Class I locations in which explosive gas atmospheres are present continuously or are present for long periods. Zone 1 Class I locations in which: i. explosive gas atmospheres are likely to occur in normal operation; or ii. explosive gas atmospheres may exist frequently because of repair or maintenance operations or because of leakage; or iii. the location is adjacent to a Class I, Zone 0 location, from which explosive gas atmospheres could be communicated. Zone 2 Class I locations in which: iv. explosive gas atmospheres are not likely to occur in normal operation and if they do occur they will exist for a short time only; or v. flammable volatile liquids, flammable gases or vapours are handled, processed, or used, but in which liquids, gases or vapours are Class I Equipment
Electrical equipment that is approved for use in Class I Hazardous Location Areas (HLAs) is referred to as explosion proof or flameproof. What this designation means is that the equipment has been designed and manufactured to ensure that it will not become a source of ignition when used in a Class I, Gas and Vapour HLA.
Cooled Escaping Gas

normally confined within closed containers or closed systems from which they can escape only as a result of accidental rupture or breakdown of the containers or systems or the abnormal operation of the equipment by which the liquids or gases are handled, processed or used; or vi. explosive gas atmospheres are normally prevented by adequate ventilation but which may occur as a result of failure or abnormal operation of the ventilation system; or vii. the location is adjacent to a Class I, Zone 1 location from which explosive gas atmospheres could be communicated, unless such communication is prevented by adequate positive-pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided.

All explosion proof equipment is clearly identified by either: a Class I Location marking (Division System); or a Type of protection d marking (IEC Zone System).

Integral Sealing Compound

Hot or burning gases

Internal Explosion
Hot or burning gases Cooled Escaping Gas

This diagram illustrates the escape paths of gases generated by an explosion within an electrical enclosure. When an explosion occurs, hot or burning gases pass through the threaded joint or StarTeck XP flame path and must make a number of changes in direction. These changes in direction cool the hot gases to the point that they are too

cool to ignite the surrounding atmosphere once they escape. Other escape paths for the hot gases include the enclosure cover flange and the interstices between the strands of wires entering the enclosure.

Hazardous Locations C.E.C. Classications


Class I (continued)
Gas Group Designations Two systems of groupings for gases are included in the 1998 C.E.C: the pre-1998 Division Gas Groups consisting of Groups A, B, C and D; and the IEC System consisting of Groups IIA, IIB and IIC. Both systems are accepted by the C.E.C.

Comparison of Hazardous Location Gas Group Designations From Most Restrictive to Least Restrictive
Typical Gas Hazard Division Gas Groups 1998 CEC and IEC Gas Groups

Acetylene Hydrogen Ethylene Propane

A B C D

IIC IIB IIA

Division Gas Groups Group A acetylene Group B butadiene, ethylene oxide, hydrogen, manufactured gases containing more than 30% hydrogen (by volume), propylene oxide. Group C acetaldehyde, cyclopropane, diethyl, ether, thylene, unsymmetrical dimethyl hydrazine (UDMH 1, 1-dimethyl hydrazine). I.E.C. Zone Gas Groups

Group IIC acetylene, butadiene, propylene oxide, carbon disulphide, hydrogen or other gases or vapour of equivalent hazard

Group IIB cyclopropane, diethyl ether, ethylene, ethylene oxide, hydrogen sulfide, unsymmetrical dimethyl hydrazine (UDMH) or other gases or vapour of equivalent hazard

Group D acetone, acrylonitrile, alcohol, ammonia, benzene, benzine, benzol, butane, 1-butanol, 2-butanol, butyl acetate, isobutyl acetate, ethane, ethanol, ethyl acetate, ethylene dichloride, gasoline, heptanes, hexanes, isoprene, methane, methanol, 3-methyl-1-butanol, methyl ethyl ketone, 2-methyl-1-propanol, 2-methyl-2-propanol, naphtha, natural gas, petroleum naphtha, octanes, pentanes, 1-pentanol, propane, 1-propanol, 2-propanol, propylene, styrene, toluene, vinyl acetate, vinyl chloride, xylenes

Group IIA acetaldehyde, acetone, acrylonitrile, alcohol, ammonia, benzine, benzol, butane, ethylene dichloride, gasoline, hexane, isoprene, lacquer solvent vapours, naptha, natural gas, propane, propylene, styrene, vinyl acetate, vinyl chloride, xylenes or other gases or vapour of equivalent hazard

10

Hazardous Locations C.E.C. Classications


Class II Dust Environments
Locations which are deemed hazardous due to the presence of combustible or electrical conducting dusts. Class II locations normally require that enclosures and connectors be dust tight.

Class III Fibers and Flyings Environments


Locations which are deemed hazardous due to the presence of easily ignitable fibers or flyings, but in which such fibers or flyings are not likely to be in suspension in the air in sufficient quantities to produce ignitable mixtures. Class III locations normally require that enclosures and connectors be constructed to minimize the entry of fibers or flyings.

Class II and III Divisions


Class II and Class III locations are further subdivided as follows: Division 1 Where the hazardous atmosphere is expected to be present during normal operations on a continuous, intermittent or periodic basis. Division 2 Where volatile, flammable liquids or gases are handled, processed or used, but in which they would normally be confined within closed containers or closed systems from which they can escape only in the event of an accidental rupture or breakdown of the containers or systems.

Class II and III Gas Group Designations


The Canadian Electrical Code (C.E.C.), Part 1 Section 18 - Hazardous Locations defines various groups which have been established for the purpose of testing and approval. Group E Comprising atmospheres containing metal dust including aluminum, magnesium, and their commercial alloys, and other metals of similarly hazardous characteristics. Group F Comprising atmospheres containing carbon black, coal or coke dust. Group G Comprising atmospheres containing flour, starch or grain dust, and other dusts of similarly hazardous characteristics.

11

Hazardous Locations Class, Zone and Division Certications


Class I I.E.C. Zone System C.E.C. Division (pre-1998) System
Watertight 10464 Series StarTeck StarTeck XP StarTeck Extreme StarTeck Extreme StarTeck Extreme XP ST050 to ST400 STX050 to STX400 STE050 to STE200 STE250 to STE400 STEX050 to STEX400

With SC4-KIT, SC65 integral sealing compound Zone 1 Groups IIC, IIB, IIA Division 1 Groups A, B, C, D Zone 2 Groups IIC, IIB, IIA Division 2 Groups A, B, C, D Not Certified Not Certified Not Certified Not Certified

Certified

Certified

Not Certified

Not Certified

Certified

Not Certified

Not Certified

Certified

Used with an Class1 HLA sealing fitting Zone 1 Groups IIC, IIB, IIA Division 1 Groups A, B, C, D Zone 2 Groups IIC, IIB, IIA Division 2 Groups A, B, C, D Not required since certified with integral seal Not required since certified with integral seal Not required since certified with integral seal Not required since certified with integral seal

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Classes II and III, Divisions 1 and 2


Watertight 10464 Series Class II Divisions 1, 2 Groups E, F, G Class III Divisions 1, 2 Enclosure Type 6P (Immersion) Enclosure Type 4 (Watertight) Certified Not Certified Certified Not Certified Certified Not Certified Certified Certified Not Certified Certified Not Certified StarTeck StarTeck XP StarTeck Extreme StarTeck Extreme StarTeck Extreme XP ST050 to ST400 STX050 to STX400 STE050 to STE200 STE250 to STE400 STEX050 to STEX400

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Certified

Comparison of Division and I.E.C. Zone Systems


Class 1 Division System I.E.C. Zone System Notes

Zone 0 Gases and Vapours Division 1 Zone 1 Division 2 Zone 2

Zone 0 locations are a small percentage of all hazardous locations. While the wiring practices and acceptable products differ, Class I, Division 1 locations encompass both Zones 0 and 1. Zone 2 and Division 2 are essentially the same.

12

Quick Reference
Thomas & Betts Teck Fittings
Cable Hub Size 14/2 14/3 14/4 14/6 14/8 14/10 14/20 12/2 12/3 12/4 10/2 10/3 10/4 8/3 8/4 6/3 6/4 4/3 3/3 2/3 1/3 1/0/3 2/0/3 3/0/3 4/0/3 250/3 300/3 350/3 400/3 500/3 600/3 750/3 Hub Size 1/2 1/2 1/2 1/2 1/2 3/4 1 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 StarTeck (pp. 14, 15) StarTeck XP (pp. 16, 17) StarTeck Extreme (pp. 18, 19) StarTeck Extreme XP (pp. 24, 25) Watertight 10464 Series (p. 26)

StarTeck (ST) Series

StarTeck XP (STX) Series

StarTeck Extreme (STE) Series

ST050-464 STX050-464 STE050 STEX075 10464 ST050-464 STX050-464 STE050 STEX075 10464 ST050-464 STX050-464 STE050 STEX075 10464 ST050-465 STX075-465 STE050 STEX075 10465-TB ST050-466 STX075-466 STE050 STEX075 10466 ST075-467 STX075-467 STE075 STEX075 10467 ST100-469 STX100-468 STE100 STEX100 10469 ST050-464 STX050-464 STE050 STEX075 10464 ST050-464 STX050-464 STE050 STEX075 10464 ST050-465 STX075-465 STE050 STEX075 10465-TB ST050-464 STX050-464 STE050 STEX075 10464 ST050-465 STX075-465 STE050 STEX075 10465-TB ST050-465 STX075-465 STE050 STEX075 10465-TB ST075-467 STX100-467 STE075 STEX100 10466 ST075-467 STX100-467 STE075 STEX100 10467 ST075-468 STX100-468 STE075 STEX100 10468 ST100-469 STX125-469 STE100 STEX125 10468 ST100-469 STX125-469 STE100 STEX125 10469 ST100-469 STX125-469 STE100 STEX125 10469 ST125-470 STX150-470 STE125 STEX125 10469 ST125-550 STX150-550 STE125 STEX150 10470 ST125-550 STX150-550 STE150 STEX150 10470 ST150-472 STX200-472 STE150 STEX200 10471 ST150-472 STX200-472 STE150 STEX200 10471 ST200-551 STX200-473 STE200 STEX200 10472 ST200-474 STX200-474 STE200 STEX250 10473 ST200-474 STX200-474 STE200 STEX250 10474 ST200-475 STX250-475 STE200 STEX250 10474 ST250-477 STX250-475 STE250 STEX300 10475 ST250-478 STX300-478 STE250 STEX300 10476 ST300-479 STX300-479 STE300 STEX300 10477 ST300-480 STX350-480 STE300 STEX350 10478 *For reference only. Suggested cable size may vary with cable manufacturer specifications.

StarTeck Extreme XP (STEX) Series

10464 Series

13

Star Teck (ST) Series Fittings for Teck and ACWU Cable
Easy Installation Inside StarTeck

1. Prepare cable

Materials and Finishes Available in a broad range of materials and finishes. Aluminum, steel, stainless steel, PVC coated.

Built-in O-Ring provides 360 seal even when enclosure surface is rough or uneven.

Easy Installation and Dependable Grounding Exclusive power-grip. Provides a grip thats high up on the cable not on the first convolution so precise cable preparation is not critical.

Sharp Biting Teeth provide superior electrical bonding and allow corrosive liquids to drain away quickly.

Watertight Tapered bushing. Cone shaped to provide a secure, tight fit while eliminating cupping or water in vertical installations.

2. Insert cable

Dependable Grounding Power-Grip grounding ring is non-magnetic stainless steel. Provides 360 long-term dependable grounding. It makes immediate contact with the cable.

Easy to Install in Tight Spaces Low profile gland nut fits tight spaces. Has grooves for screwdriver installation, and flats for a wrench. Durable and reusable with funnel entry for easy cable insertion.

Dependable Service Stainless steel retaining ring. Withstands corrosive environments. Non-magnetic.

3. Tighten gland nut

Warning: Always ensure that the system is de-energized before performing any installation.

Suggested specifications for metal-clad cable or teck cable fittings in hazardous locations:
1. All metal-clad cable fittings for jacketed and non-jacketed interlocked armor cable, continuous corrugated cable or teck cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization. 2. Where corrugated-jacketed, metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the fitting shall be watertight type furnished with: a. an elastomeric beveled bushing. b. a funnel entry, splined gland nut. c. a non-magnetic, stainless steel grounding device with dual grounding action. d. a taper threaded hub. e. a hexagonal body and gland nut as manufactured by Thomas & Betts (aluminum series ST050-464). 3. Where cable is terminated into a threadless opening, a suitable moisture resistant elastomeric gasket as manufactured by Thomas & Betts, series 5262, shall be provided between the outside enclosure and fitting shoulder. 4. With single conductor cable and/or in corrosive environments, aluminum fittings such as Thomas & Betts series ST050-464 shall be installed. Where explosion-proof or dust-ignition-proof boxes are required by the code, StarTeck fittings must be used in conjunction with an approved sealing fitting.

14

Star Teck (ST) Series Fittings for Teck and ACWU Cable

Cat. No.

Hub Size N.P.T. 3/8 1/2 1/2 1/2 1/2 3/4 3/4 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 2 2 2 2 2-1/2 2-1/2 3 3 3 3-1/2 3-1/2 4 4 4

Range Over Jacket (in.) min. 0.344 0.525 0.600 0.725 0.825 0.880 1.025 1.187 1.350 1.500 1.600 1.700 1.900 1.900 2.100 2.300 2.500 2.380 2.580 2.790 3.000 3.210 3.420 3.610 3.810 3.965 4.120 max. 0.535 0.650 0.760 0.885 0.985 1.065 1.205 1.375 1.625 1.625 1.875 1.965 2.187 2.187 2.375 2.565 2.750 2.640 2.840 3.060 3.270 3.480 3.690 3.870 4.030 4.185 4.340 A 0.344 0.390 0.480 0.607 0.607 0.809 0.809 1.034 1.177 1.365 1.365 1.552 1.595 1.710 1.990 2.052 2.052 2.255 2.455 2.655 2.885 3.057 3.285 3.455 3.625 3.770 3.935

Dimensions (in.) B* 2.020 2.020 2.020 2.133 2.133 2.450 2.450 2.601 3.282 3.282 3.282 3.620 3.620 3.640 3.640 3.640 3.640 4.700 4.700 4.700 4.790 4.790 4.790 4.790 4.840 4.840 4.840 C 0.995 1.224 1.363 1.633 1.633 2.080 2.080 2.230 2.824 2.824 2.824 3.260 3.260 3.620 3.620 4.020 4.020 4.750 4.750 5.050 5.480 5.480 5.980 5.980 6.435 6.435 6.435

StarTeck (ST) Series Star Teck cable fittings are designed to accommodate a broad range of cables, thereby minimizing the possibility of mismatched cables and fittings in the field. They are available in hub sizes from 1/2 to 4 inches, and will handle outer jacket diameters from 0.525 to 4.340 inches.

C Retaining ring (stainless steel) Bushing (elastomer) Gland nut (aluminum) B Grounding ring (stainless steel)

Body (aluminum) O-Ring (elastomer) Hub

ST038-461S ST050-462 ST050-464 ST050-465 ST050-466 ST075-467 ST075-468 ST100-469 ST125-470 ST125-550 ST125-471 ST150-472 ST150-473 ST200-551 ST200-474 ST200-475 ST200-476 ST250-477 ST250-478 ST300-479 ST300-480 ST300-481 ST350-482 ST350-483 ST400-484 ST400-485 ST400-486

* Approximate dimension before installation.


Only available in steel Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. The body and gland nut on hub sizes 1/2 to 1 inch are machined from copper-free bar stock and 1-1/4 to 4 inches are made of cast copper-free aluminum. Steel: To order a steel or malleable iron fitting, add the suffix S to the catalogue number (example ST050-464S). The body and gland nut on hub sizes 1/2 to 1 inch are made of steel and 1-1/4 to 4 inches are made of malleable iron. Plating is electro-deposited zinc. Stainless Steel: To order a 316 stainless steel fitting, add the suffix SS to the catalogue number (example ST050-464SS). Only available for 1/2 thru 2 inch hub sizes. PVC-Coated Aluminum and Steel: To order, add the suffix PVC to the catalogue number (example ST050-464PVC or ST050-464SPVC). Note - When using fittings on single conductor cable, aluminum fittings and aluminum locknuts must be used. Certifications Type HLA. CSA Certified Class II, Divisions 1 and 2, Groups E, F, and G; Class III and Enclosure Type 4, Type 4X, Classes I, II and III. These fittings are suitable for Class I hazardous locations when used in combination with a certified Class I hazardous location sealing fitting. CSA File No. LR-23086. Complies with IEC requirements for Class I, Zones 1 and 2, when used in combination with a certified Class I hazardous location sealing fitting. U.L. Listed Class I, Division 2; Class II, Division 2 and Class III. Meets sealing requirements for types 4 and 6 enclosures. File no. E-38947. PVC-coated fittings are only approved for ordinary location areas (OLA).

Star Teck XP (STX) Series Fittings for Teck Cable


Easy Installation Inside StarTeck XP

Easy Installation Hub has hexagonal shape for dependable tool grip.

1. Prepare cable

User-friendly Internal splines allow installer to tighten gland nut either on or off enclosure.

Easy Fill and Assembly Sealing chamber is easier to fill, requires less sealing compound saves time, material. Flame path is optimally designed to allow for easy insertion into hub. Quick-turn lock unitizes assembly during installation.

2. Install StarTeck XP on cable

Highly Efficient, Highly Visible Union features twist-on action for easy connection and disconnection; red color assures high visibility, easy recognition. Union also serves as a puller during disassembly.

Exclusive Power Grip Provides grip thats high upon cable armor not on first convolution so precise cable preparation is not critical. Non-magnetic stainless steel Power Grip grounding ring assures 360 long-term dependable grounding. Also provides phenomenal tensile pullout resistance.

Corrosion Resistant Copper-free construction. All-aluminum body and gland nut resist corrosion and oxydation.

Easy to Install in Tight Spaces Low profile gland nut fits tightest spaces. Has grooves for hammer/ screwdriver installation and flats for wrench-gripping. Durable and reusable with funnel entry for easy cable insertion.

3. Tighten gland nut

Dependable Service Stainless steel retaining ring. Withstands corrosive environments. Non-magnetic.

Secure, Tight Fit Tapered bushing. Cone-shaped to provide secure, tight fit while eliminating cupping of water in vertical installations.

Suggested specifications for metal-clad cable or teck cable fittings in hazardous locations:
1. All metal-clad cable fittings for jacketed and non-jacketed interlocked armor cable, continuous corrugated cable or teck cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization. 2. Where corrugated-jacketed, metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the fitting shall be watertight type furnished with: a. an elastomeric beveled bushing. b. a funnel entry, splined gland nut. c. a non-magnetic, stainless steel grounding device with dual grounding action. d. a taper threaded hub. e. a hexagonal body and gland nut as manufactured by Thomas & Betts, STX050-464. 3. With single conductor cable and/or in corrosive environments, aluminum connectors such as Thomas & Betts Series STX050-464 shall be installed. 4. In hazardous location applications, the fitting shall be of the integral seal type with metal-to-metal contact construction such as Thomas & Betts StarTeck XP series. Sealing of multi-conductor cable shall be accomplished with a liquid type polyure-thane compound such as Thomas & Betts series SC4-KIT. Putty type sealing compound such as Thomas & Betts series SC65 may be used for other applications. 5. The fitting must: a. Provide an environmental seal around the outer jacket of the cable and electrically bond the fitting to the cable armor prior to potting the explosion-proof seal. b. Allow the possibility of disconnection without disturbing the environmental seal, the electrical bonding or the explosionproof seal. 6. All metal-clad cable fittings, for jacketed and non-jacketed interlocked armor cable, shall incorporate an easily-removable armor stop (not requiring fitting disassembly) ensuring proper positioning of the cable armor during cable termination, such as Thomas & Betts series STX050-464.

4. Pot cable (using liquid or putty)

5. Install hub on enclosure

6. Insert cable and tighten red union 16

Warning: Always ensure that the system is de-energized before performing any installation.

Star Teck XP (STX) Series Fittings for Teck Cable

Cat. No.

Hub Size N.P.T. 1/2 1/2 3/4 3/4 1 1 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 2-1/2 3 3 3-1/2 3-1/2 4 4 4 4

Max. Vol. of Sealing Compound (cc) 5 5 8 8 16 16 23 43 43 43 72 72 72 147 147 286 286 366 366 614 614 614 614

Range Over Jacket (in.) min. 0.525 0.600 0.725 0.825 0.880 1.025 1.187 1.350 1.500 1.600 1.700 1.900 2.100 2.300 2.500 2.580 2.790 3.000 3.210 3.420 3.610 3.810 3.965 max. 0.650 0.760 0.885 0.985 1.065 1.205 1.375 1.625 1.625 1.875 1.965 2.187 2.375 2.565 2.750 2.840 3.060 3.270 3.480 3.690 3.870 4.030 4.185 A (min.) 0.395 0.485 0.607 0.715 0.750 0.895 1.057 1.177 1.365 1.465 1.552 1.752 1.990 2.180 2.360 2.455 2.655 2.859 3.057 3.285 3.455 3.625 3.770

Dimensions (in.) B* 2.50 2.50 2.62 2.62 2.83 2.83 3.05 3.76 3.76 3.76 4.05 4.05 4.15 4.31 4.31 5.64 5.80 6.32 6.32 6.63 6.63 7.09 7.09 C 1.63 1.63 1.82 1.82 2.30 2.30 2.51 3.26 3.26 3.26 3.62 3.62 4.02 4.58 4.58 5.10 5.33 5.79 5.79 6.19 6.19 6.90 6.90

Series StarTeck XP (STX) Star Teck XP cable fittings are designed to accommodate a broad range of cables, thereby minimizing the possibility of mismatched cables and fittings in the field. They are available in hub sizes from 1/2 to 4 inches, and will handle outer jacket diameters from 0.525 to 4.185 inches.

Hub (aluminum) Union (aluminum) O-Ring (elastomer) Body (aluminum) Grounding Ring (stainless steel)

Sealing Chamber (aluminum)

Retaining Ring (stainless steel) Gland Nut (aluminum) Bushing (elastomer)

STX050-462 STX050-464 STX075-465 STX075-466 STX100-467 STX100-468 STX125-469 STX150-470 STX150-550 STX150-471 STX200-472 STX200-473 STX200-474 STX250-475 STX250-476 STX300-478 STX300-479 STX350-480 STX350-481 STX400-482 STX400-483 STX400-484 STX400-485

Note - Sealing compound not included. Order separately. Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. Steel: To order a steel fitting, add the suffix S to the catalogue number (example STX050-464S). Certifications Type HLA. CSA Certified Class I, Divisions 1 and 2, Groups A, B, C and D; Class II, Divisions 1 and 2; Groups E, F and G; Class III, SL (integral seal) and Enclosure Type 4 and 4X. CSA File No. LR-23086. Complies with IEC requirements for Class 1, Zones 1 and 2, Groups IIC, IIB and IIA. U.L. Listed for 1/2 through 3 inches when used with putty or liquid type compound: Class 1, Divisions 1 and 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Class III and Enclosure Type 4 and 4X. File No. E-82038. U.L. Listed for 3-1/2 and 4 when used with putty or liquid type compound: Class 1, Divisions 1 and 2, Groups B, C and D; Class II, Division 2, Groups F and G; Class III and Enclosure Type 4 and 4X. File No. E-82038.

* Approximate dimension before installation.

Sealing Compounds
Cat. No. Description Volume (cubic centimeter)

SC4-KIT

Liquid type sealing compound (includes pouch of sealing compound with integral spout, fiber and damming material).

66 cc

Use SC4-KIT liquid compound for shielded cables.


Cat. No. Description Volume (cubic centimeter)

SC4-KIT SC65

Putty type sealing compound (cut-to-length stick)

34 cc

SC65 For more details, refer to the installation/ Instruction sheet.

Suitable for use on cables with a maximum of four conductors (including ground). We do not recommend SC65 for use with shielded cables. Quantity of compound required will vary according to cable conductor fill. U.L. File No. E-82038 CSA File No. LR-23086
Note - Thomas & Betts hazardous locations fittings with integral seals (STX, STEX, HLT and TC series) are UL and CSA certified only when used with SC4-KIT or SC65 sealing compounds. No other sealing compounds have been tested, certified or listed.

17

Star Teck Extreme (STE) Series Fittings for Teck Cable and ACWU Cable
Easy Installation Inside StarTeck Extreme

Removable armor-stop is factory installed. Fittings come ready to install on smallest cable in its range. For larger cables, no fitting disassembly required. Simply unscrew armor-stop and discard.

Sharp biting teeth provide superior electrical bonding and allow corrosive liquids to drain away quickly.

1. Prepare cable.

Built-in sealing device provides 360 O seal even when enclosure surface is rough or uneven.

Exclusive power-grip. Provides a grip thats high up on the cable not on the first convolutionso jacket strip length of cable is not critical.

Copper-free construction. Non-corrosive all aluminum body and gland nut.

Power Grip grounding ring is non-magnetic stainless steel. Dual sets of grounding devices ensure 360 0 long-term dependable grounding. It makes immediate contact with the cable during insertion.

Tapered elastomeric bushing. Cone shaped to provide a secure, tight fit while eliminating cupping of water in vertical installations.

Built-in jacket stripping gauge on each fitting.

2a. Insert cable.

Elastomeric collar ring extends cable diameter range per fitting. Matching cable to fitting hub size is made easy. (NOTE : The STE 050-DATA collar ring is made of stainless steel.)

Low profile gland nut fits tight spaces. Has grooves for screwdriver installation, and flats for a wrench. Durable and reusable with funnel entry for easy cable insertion.

Suggested specifications for metal-clad cable or teck cable fittings in hazardous locations:
2b. For larger cables, unscrew and discard armor-stop. 1. All metal-clad cable fittings for jacketed and non-jacketed interlocked armor cable, continuous corrugated cable or teck cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization. 2. Where corrugated-jacketed, metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the fitting shall be watertight type furnished with: a. an elastomeric beveled bushing. b. a funnel entry, splined gland nut. c. a non-magnetic, stainless steel grounding device with dual grounding action. d. a taper threaded hub. e. a hexagonal body and gland nut as manufactured by Thomas & Betts (aluminum series STE050). 3. A synthetic rubber sealing device shall be captivated in a face groove providing optimized sealing even on irregular surfaces. The configuration shall also prevent over-compression of the seal such as Thomas & Betts series STE050, by incorporation an easily removable armor-stop. 4. With single conductor cable and/or in corrosive environments, aluminum fittings such as Thomas & Betts series STE050 shall be installed. 5. All metal-clad cable fittings, for jacketed and non-jacketed interlocked armor cable, shall provide external bonding/grounding teeth capable of penetrating surface finishes to contact enclosure base metal. (Thomas & Betts series STE050). 6. All metal-clad cable fittings, for jacketed and non-jacketed interlocked armor cable, shall incorporate an easily removable armor-stop, not requiring fitting disassembly) ensuring proper positioning of the cable armor during cable termination. (Thomas & Betts series STE050).

3. Tighten gland nut.

Warning: Always ensure that the system is de-energized before performing any installation.

18

Star Teck Extreme (STE) Series Fittings for Teck Cable and ACWU Cable
Hub Strip Gland Size Lenght Torque N.P.T. (in.) (lb-in.) 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 7/8 1-1/4 1-1/4 1-1/4 1-3/4 1-3/4 1-3/4 2-1/2 2-1/2 2-1/2 2-1/2 300 300 600 700 1000 1200 1600 1600 1600 1600 1600 A1 A2 Range Over Range Over C Throat Dia. Throat Dia. Jacket Armor B* Max. Min. (in.) Min. (in.) (in.) (in.) Overall O.D. w/ Armor w/o Armor in.) (in.) Min. Max. Min. Max. Stop Stop 0.500 0.600 0.860 0.950 1.150 1.440 1.825 2.265 2.670 3.220 3.665 0.700 0.985 1.205 1.375 1.625 1.965 2.375 2.840 3.270 3.870 4.340 0.410 0.520 0.780 0.870 0.990 1.280 1.665 2.105 2.545 3.090 3.550 0.610 0.895 1.125 1.295 1.465 1.805 2.215 2.680 3.145 3.640 4.225 0.515 0.505 0.645 0.785 0.970 1.260 1.645 2.075 2.531 3.065 3.525 0.375 0.617 0.819 1.044 1.250 1.562 1.995 2.424 2.890 3.414 3.914 2.100 2.520 2.840 3.020 4.010 4.290 4.120 5.670 5.780 5.740 5.790 1.360 1.630 2.080 2.300 2.820 3.250 3.600 4.750 5.400 5.900 6.400

Cat. No.

StarTeck Extreme fittings are designed to accommodate a broad range of cables and each hub size overlaps the adjacent hub range, thereby minimizing the possibility of mismatched cables and fittings in the field. Available in hub sizes from 1/2 to 4 inches, StarTeck Extreme fittings will terminate outer jacket diameters from 0.500 to 4.340.

STE050-DATA STE050 STE075 STE100 STE125 STE150 STE200 STE250 STE300 STE350 STE400

Collar Ring (elastomer) (stainless steel for STE 050-DATA) Bushing (elastomer) Glandnut (aluminum) Grounding Ring (stainless steel)

Body (aluminum) Sealing Ring (elastomer)

Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. Steel: The body and gland nut on hub sizes 1/2 to 1-1/2 inch are made of steel. The body and gland nut on 2- to 4-inch hub sizes are made of malleable iron.To order a steel fitting, add the suffix S to the catalogue number (example STE050S). Certifications Type HLA. CSA Certified Class II, Divisions 1 and 2, Groups E, F, and G; Class III and Enclosure 1/2 to 2 Type 4, 4X and 6P, 2-1/2 to 4 Type 4 and 4X, Classes I, II and III. These fittings are suitable for Class I hazardous locations when used in combination with a certified Class I hazardous location sealing fitting. CSA File No. LR-23086. Complies with IEC requirements for Class 1, Zones 1 and 2, when used in combination with a certified Class I hazardous location sealing fitting. U.L. Listed for metal clad cable, Type 6P. STE050-Data is U.L. Listed with cables from 0.592 to 0.693 over jacket. Note -To order fittings complete with aluminum BondStar locknut and lug, add the suffix GRL to the catalogue number (example STE050GRL). For complete details refer to pages 20, 21 of this catalogue.

* Approximate dimension before installation.

Broadest range of teck cable diameters per hub size


StarTeck Extreme Cat. No. StarTeck Cat. No. Hub Size (NPT) (in.) Range over Jacket (in.) Min. - Max.

Eleven catalogue numbers cover the range from 0.500 to 4.340 inches.
Removable Armor Stop (nylon: 1/2-1) (aluminum: 1-1/4-2)

STE050-DATA STE050 0.600 - 0.985 STE075 0.860 - 1.205 STE100 0.950 - 1.375 STE125 1.150 - 1.625 STE150 1.440 - 1.965 STE200 1.825 - 2.375 STE250 2.265 - 2.840 STE300 2.670 - 3.270 STE350 3.220 - 3.870 STE400 3.665 - 4.340

Hub

ST038-461S ST050-462 ST050-464 ST050-465 ST050-466 ST075-467 ST075-468 ST100-469 ST125-470 ST125-550 ST125-471 ST150-472 ST150-473 ST200-551 ST200-474 ST200-475 ST200-476 ST250-477 ST250-478 ST300-479 ST300-480 ST300-481 ST350-482 ST350-483 ST400-484 ST400-485 ST400-486

3/8 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

0.344 - 0.535 0.500 - 0.700 0.525 - 0.650 0.526 - 0.760 0.725 - 0.885 0.825 - 0.985 0.880 - 1.065 1.250 - 1.205 1.187 - 1.375 1.350 - 1.625 1.500 - 1.625 1.600 - 1.875 1.700 - 1.965 1.900 - 2.187 1.900 - 2.187 2.100 - 2.375 2.300 - 2.565 2.500 - 2.750 2.380 - 2.640 2.580 - 2.840 2.790 - 3.060 3.000 - 3.270 3.210 - 3.480 3.420 - 3.690 3.610 - 3.870 3.810 - 4.030 3.965 - 4.185 4.120 - 4.340

19

Bond Star Grounding Locknut

Extreme grounding for data and control applications. For data and control panel applications or any other installation that is highly sensitive to floating voltage differences, the complete range of StarTeck Extreme fittings (1/2 inch to 4-inch hub sizes) is also available with a 3-position grounding locknut including an open-sided lay-in lug made of tin-plated aluminum. With a #4-14 AWG wire range, the CSA and UL approved grounding lug can be positioned on the most accessible of the three grounding locations on the

circumference of the installed grounding locknut. When installation requires multiple incoming cables, each individual lug terminating the connections can be daisy chain bonded to the grounding bus, ensuring the same electrical potential throughout the cables. BondStar grounding locknuts can also be used with the complete range of Thomas & Betts teck cable fittings. To order individually, use the catalogue numbers shown on page 21.

Exclusive BondStar grounding locknut is ideal for any application that is sensitive to floating voltage differences.

BondStar Open-sided lay-in grounding lug is CSA and UL approved and as a #4-14 AWG wire range.

BondStar Choice of three grounding locations on the circumference of the installed grounding locknut facilitates installation of grounding lug.

20

Bond Star Grounding Locknut


StarTeck Extreme Fittings with BondStar Grounding Locknut
Cat. No. Hub Sizes (N.P.T.) (in.) 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Obsoleted Items STE050-DATA STE050GR STE075GR STE100GR STE125GR STE150GR STE200GR STE250GR STE300GR STE350GR STE400GR

STE050-DATAGRL STE050GRL STE075GRL STE100GRL STE125GRL STE150GRL STE200GRL STE250GRL STE300GRL STE350GRL STE400GRL

BondStar Grounding Locknut only


Cat. No. Sizes (in.) 1/2 3/4 1 1-1/4 1-1/2 2-1/2 3 3-1/2 4 5 6 Description

L050GRL L075GRL L100GRL L125GRL L150GRL L250GRL L300GRL L350GRL L400GRL L500GRL L600GRL

Locknut with Lay-in Lug and Screw

Lay-in Lug
Cat. No. Screw #10, 32 TPI 1/4, 20 TPI For Hub Sizes (in.) 1/2, 3/4, 1 1-1/4 - 6

GRL-LUG1032 GRL-LUG1/4-20

21

Star Teck Extreme Director TM (STED) Teck Cable Fittings

New!

Install tting into enclosure

Insert cable & tighten (as usual)

Rotate tting to desired angle

Warning: Always ensure that the system is de-energized before performing any installation.

22

Star Teck Extreme Director TM (STED) Teck Cable Fittings

STAR TECK EXTREME DIRECTORTM Cable Fittings


Cat. No. Hub Size N.P.T. Gland Torque (lb.-in.) Range Over Jacket (in.) Range Over Armour (in.) Throat Dia. (Min. in.) With Without Armour Stop Armour Stop 0.505 0.645 0.617 0.819 Overall (in.)

min. 0.600 0.860

max. 0.885 1.205

min. 0.520 0.780

max. 0.795 1.125

STED050 STED075

1/2 3/4

450 600

5.375 5.875

Specications: Type HLA. CSA Certied Class I, Division 2; Class II, Groups E, F and G, Class III Enclosure Types 4, 4X; Ex e II, IP66. CSA File 23086. Type 6 UL listed le E-38947 For use with jacketed teck cable, jacketed corrugated metal-clad cable (ACWU) or metal-clad cable (MC). Aluminum or steel armour.

Assembly:
seal ring

removable armour stop

hub

body

clamp

blue compression nut

grounding ring

bushing

upper bushing gland nut

23

Star Teck Extreme XP (STEX) Series Fittings for Teck Cable


Easy Installation Inside the StarTeck Extreme XP
Built-in O-Ring to ensure liquidtight installation. Removable armor-stop is factory installed. Fitting comes ready to install on smallest cable in its range. No disassembly required for larger cables simply unscrew and discard armor-stop. This makes the fitting very range taking.

1. Prepare cable
Copper-free construction non-corrosive all aluminum body and gland nut.

High visibility, red union features twist-on action for easy connection and disconnection. Also serves as mechanical splitter to separate hub from fitting during disassembly.

2. Install StarTeck Extreme XP on cable

Exclusive power-grip provides a grip thats high up on the cable not on the first convolution so precise cable preparation is not critical.

Power Grip grounding ring is non-magnetic tin-plated phosphorous bronze or stainless steel. Dual sets of grounding devices ensure 360 0 long-term dependable grounding. Makes immediate contact with the cable during insertion.

Tapered elastomeric bushing cone shaped to provide a secure tight fit while eliminating cupping of water in vertical installations.

Built-in cable jacket stripping gauge

3. Tighten gland nut

Low profile gland nut fits tight spaces. Has grooves for screwdriver installation, and flats for a wrench. Durable and reusable with funnel entry for easy cable insertion.

Elastomeric collar ring extends cable diameter range per fitting. Matching cable to fitting hub size is easy.

4. Remove armor stop

Easy to fill sealing chamber requires less sealing compound saves time and materials. Optimally designed flame path for easy insertion into hub. Quick-turn lock unitizes assembly during installation. Note : The red armor stop must be removed and discarded prior to potting the fitting.

Suggested specifications for metal-clad cable or teck cable fittings in hazardous locations:
1. All metal-clad cable fittings for jacketed and non-jacketed interlocked armor cable, continuous corrugated cable or teck cable shall be approved by a nationally recognized testing laboratory, inspection agency or product evaluation organization. 2. Where corrugated-jacketed, metal-clad cable exposed to intermittent or continuous moisture is terminated into a threaded opening, the fitting shall be watertight type furnished with: a. an elastomeric beveled bushing or bushings. b. a funnel entry, splined gland nut. c. a non-magnetic, tin-plated phosphorous bronze or stainless steel grounding device with dual grounding fingers. d. a taper threaded hub. e. a hexagonal body and gland nut as manufactured by Thomas & Betts (aluminum series STEX075). 3. With single conductor cable and/or in corrosive environments, aluminum connectors such as Thomas & Betts Series STE075 shall be installed.
Warning: Always ensure that the system is de-energized before performing any installation.

5. Pot cable using liquid or putty

4. In hazardous location applications, the fitting shall be of the integral seal type with metal-to-metal contact construction such as Thomas & Betts StarTeck Extreme XP series. Sealing of multi-conductor cable shall be accomplished with a liquid type polyurethane compound such as Thomas & Betts series SC4-KIT. Putty type sealing compound such as Thomas & Betts series SC65 may be used for other applications. 5. The fitting must: a. Provide an environmental seal around the outer jacket of the cable and electrically bond the fitting to the cable armor prior to potting the explosion-proof seal. b. Allow the possibility of disconnection without disturbing the environmental seal, the electrical bonding or the explosion-proof seal. 6. All metal-clad cable fittings, for jacketed and non-jacketed interlocked armor cable, shall incorporate an easily-removable armor stop (not requiring fitting disassembly) ensuring proper positioning of the cable armor during cable termination, such as Thomas & Betts series STEX075.

6. Insert hub on enclosure

7. Insert cable and tighten red union

Clean, professional cable terminations on the broadest range of teck cable diameters. 24

Star Teck Extreme XP (STEX) Series Fittings for Teck Cable

Cat. No.

Hub Size N.P.T. 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

Range Over Jacket (in.) Min. Max. 0.525 0.600 0.600 0.860 0.950 1.150 1.440 1.825 2.265 2.670 3.220 0.650 0.760 0.985 1.205 1.375 1.625 1.965 2.375 2.840 3.270 3.870

A1 A2 Range Over Throat Dia. Throat Dia. Armor Min. (in.) Min. (in.) (in.) w/ Armor w/o Armor Min. Max. Stop Stop 0.415 0.490 0.520 0.780 0.870 0.990 1.280 1.665 2.105 2.545 3.090 0.570 0.680 0.895 1.125 1.295 1.465 1.805 2.215 2.680 3.145 3.640 N/A*** N/A*** 0.500 0.645 0.829 0.953 1.245 1.630 2.066 2.522 3.060 0.400 0.480 0.670 0.825 1.076 1.280 1.565 2.000 2.495 2.895 3.520

B* Length (in.) 2.500 2.530 3.400 3.580 3.920 5.020 5.120 5.170 6.610 7.380 7.650

Compound C Reqd (approx.) Max. SC65 /SC4KIT O.D. Liquid (in.) (CC) 1.630 1.630 1.820 2.300 2.510 3.260 3.620 4.580 5.100 5.790 6.190 5 5 8 16 23 43 72 147 286 366 614

StarTeck Extreme fittings are designed to accommodate a broad range of cables and each hub range overlaps the adjacent hub range, thereby minimizing the possibility of mismatched cables and fittings in the field. They are available in hub sizes from 1/2 to 4 inches, and will handle outer jacket diameters from 0.525 to 3.870 inches.

STX050-462 STX050-464 STEX075 STEX100 STEX125 STEX150 STEX200 STEX250 STEX300 STEX350 STEX400

* Approximate dimension before installation.


Note - Sealing compound not included. Order separately. Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. Steel: To order a steel fitting, add the suffix "S" to the catalogue number (example STEX050S). Minimum quantities may apply (consult Customer Service) Certifications Type HLA. CSA Certified Class I, Divisions 1 and 2, Groups A, B, C and D; Class II, Divisions 1 and 2; Groups E, F and G; Class III, SL (integral seal); hub sizes 1/2 through 2-1/2 inches - Enclosure Type 6P; hub sizes 1/2, 3, 3-1/2 and 4 inches - Enclosure Type 4. CSA File No. LR-23086. Complies with IEC requirements for Class I, Zones 1 and 2, Groups IIC, IIB and IIA. U.L. Listed for 1/2 through 2 inch hub sizes when used with putty or liquid type compound: Class 1, Division 2, Groups A, B, C and D; Class II, Divisions 1 and 2, Groups F and G; Class III and Enclosure Type 6P. U.L. File No.E-82038. U.L. Listed for 3-1/2 and 4 when used with putty or liquid type compound: Class 1, Divisions 1 and 2, Groups B, C and D; Class II, Division 2, Groups F and G; Class III and Enclosure Type 4. U.L. File No. E-82038.

(3/4 to 1-tin plated phosphorous bronze; 11/4 to 4 stainless steel)

Union (red anidized aluminum)

A1 A2

SC65 For more details, refer to the installation/ Instruction sheet.

Hub (Aluminum)

Grounding Ring

Bushing (elastomer)

Collar Ring (elastomer) Glandnut (aluminum)

Body (aluminum)

O-Ring (elastomer)

Sealing Chamber (Aluminum) Removable Armor Stop (Polypropylene: 1/2-2) (Aluminum: 21/2-4)

Sealing Compounds
Cat. No. Description Volume (cubic centimeter)

SC4-KIT

Liquid type sealing compound (includes pouch of sealing compound with integral spout, fiber and damming material).

66 cc

Use SC4-KIT liquid compound for shielded cables.


Cat. No. Description Volume (cubic centimeter)

SC4-KIT SC65

Putty type sealing compound (cut-to-length stick)

34 cc

Suitable for use on cables with a maximum of four conductors (including ground). We do not recommend SC65 for use with shielded cables. Quantity of compound required will vary according to cable conductor fill. U.L. File No. E-82038 CSA File No. LR-23086
Note - Thomas & Betts hazardous locations fittings with integral seals (STX, STEX, HLT and TC series) are UL and CSA certified only when used with SC4-KIT or SC65 sealing compounds. No other sealing compounds have been tested, certified or listed.

25

10464 Series Watertight Fittings / ACWU

Cat. No.

Hub Thread Size (in.) 1/2 1/2 1/2 1/2 3/4 3/4 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 2 2 2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 3 3-1/2 3-1/2 3-1/2 4 4 4

Cable Jacket O.D. min. 0.562 0.625 0.750 0.875 0.880 1.055 1.187 1.375 1.375 1.625 1.750 1.937 2.000 2.156 2.350 2.350 2.535 2.535 2.735 2.970 2.975 3.080 3.210 3.310 3.430 3.560 3.710 3.810 3.930 4.060 max. 0.625 0.760 0.885 0.985 1.065 1.205 1.375 1.625 1.625 1.875 1.965 2.187 2.187 2.360 2.565 2.565 2.750 2.750 2.985 3.220 3.125 3.250 3.380 3.480 3.620 3.750 3.870 4.000 4.120 4.250

Throat Dia. (in.) 0.615 0.615 0.615 0.615 0.780 0.780 1.000 1.187 1.400 1.400 1.563 1.621 2.000 2.000 2.000 2.092 2.092 2.437 2.437 2.437 3.050 3.050 3.050 3.050 3.310 3.310 3.310 3.560 3.670 3.800

10462* 10464 10465-TB 10466 10467 10468 10469 10470 10550 10471 10472 10473 10551 10474 10475 10552 10476 10553 10477 10478 10554 10555 10479 10480 10481 10482 10483 10484 10485 10486

Note - When using fittings on single conductor cable, aluminum fittings and aluminum locknuts must be used. Materials Malleable Iron: The above listed catalogue numbers relate to malleable iron fittings with a protective grounding sleeve for jacketed metal-clad cable. Aluminum: To order an aluminum fitting, add the suffix "AL" to the catalogue number (example 10465AL). PVC-Coated Aluminum and Steel: Contact your Regional Sales Office for availability and ordering information. Certifications Type HLA. CSA Certified Classes I, II and III. These fittings are suitable for Class I hazardous locations when used in combination with a certified Class I hazardous location sealing fitting. CSA File No. LR-23086. Type OLA. UL Listed. These fittings are suitable for use with interlocked jacketed cable, aluminum or steel armor. UL File No. E-38947. *Cat. No. 10462 not UL Listed

26

90 Watertight Fittings and Non Watertight Fittings


90 Watertight Fittings
Cat. No. Hub Thread Size (in.) 1/2 1/2 1/2 3/4 3/4 1 Neoprene bushing min. max. 0.625 0.750 0.875 0.880 1.055 1.187 0.760 0.885 0.985 1.065 1.205 1.375 Throat Dia. (in.) 0.615 0.615 0.615 0.825 0.825 1.000

10601 10602-TB 10603 10604-TB 10605 10606-TB

Materials Malleable Iron: The above listed catalogue numbers relate to malleable iron fittings with a protective grounding sleeve for jacketed metal-clad cable. Certifications Type HLA. CSA Certified Classes I, II and III. These fittings are suitable for Class I hazardous locations when used in combination with a certified Class I hazardous location sealing fitting. CSA File No. LR-23086. Type OLA. UL Listed. These fittings are suitable for use with interlocked jacketed cable, aluminum or steel armor. UL File No. E-38947.

Non Watertight Fittings


Cat. No. Hub Size (in.) 3/4 1 1-1/4 1-1/2 2 2-1/2 Armor O.D. min. 0.562 0.687 1.000 1.313 1.563 2.000 max. 0.800 0.950 1.344 1.563 2.000 2.469

10000 10001 10002 10003 10004 10005

Material: Malleable iron CSA File No. LR-4484 Type OLA. UL Listed. These fittings are suitable for use with interlocked jacketed cable, aluminum or steel armor. UL File No. E-38947.

Non Watertight Fittings


Cat. No. Hub Size (in.) 3/4 1 1-1/4 1-1/2 2 2-1/2 min. 0.562 0.687 1.000 1.313 1.563 2.000 Armor O.D. max. 0.800 0.950 1.344 1.563 2.000 2.469

10000AL 10001AL 10002AL 10003AL 10004AL 10005AL

Material: Aluminum CSA File No. LR-4484 Type OLA. UL Listed. These fittings are suitable for use with interlocked jacketed cable, aluminum or steel armor. UL File No. E-38947.

27

Silver Grip Liquidtight Fittings for Tray Cable


The Canadian Electrical Code states that tray cable in hazardous locations can be used either within the cable tray, or outside the tray - provided there is additional protection. The TrayStar TM fitting was designed and engineered for either application and comes complete with the bushing, ground cone and sealing ring for different product applications. Ease of Installation Installation is quick and easy. When used on metallic liquidtight conduit, the fitting hub size correlates with that of the conduit trade size. (i.e. 1/2 fitting accomodates 1/2 conduit). The bushings, when utilized, are designed to accomodate a broad range of tray cable diameters. Either liquid or putty sealing compound can be used for a positive, gastight seal. The compound is ordered separately to allow for flexibility in making the correct selection for various types of installations. The sealing

Outside Tray tray cable must be protected within conduit and flexible liquidtight metallic conduit. In this case, the connector bushing is simply replaced with a ground cone/sealing ring to terminate the assembly.

compounds cure in just a few hours. The TrayStar TM fitting also has disconnect capability: the cable can be disconnected and reconnected after being sealed. The unique hexagonal gland nut is conveniently grooved for screwdriver installation in extremely cramped areas. The gland nut is also clearly identified with the catalogue number and CSA approvals. It is also anodized an aqua-blue colour to identify it as a Hazardous Location, Tray Cable Fitting. Superior Construction TrayStar TM fittings have a low-profile compact design and are made of copper-free aluminum for long-lasting trouble-free service. Fittings are precision machined for superior fit and ease of installation.

Double face tape Sealing compound

Ground cone Sealing ring

Ordering Information
Body Putty insert Gland nut

With conduit
Cat. No.

Hub Size

HLT050DATA HLT050 HLT075 HLT100 HLT125 HLT150 HLT200 4-250TC 4-300TC 4-350TC 4-400TC Inside Tray Used with a neoprene bushing, TrayStar TM terminates tray cable within the tray itself.
Sealing compound B Bushing Not UL Listed

N.P.T. 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

Range Over Jacket (in.) min. max. 0.250 0.310 0.300 0.400 0.320 0.570 0.400 0.750 0.625 1.000 0.780 1.200 1.000 1.560 1.700 2.150 2.650 3.180 2.200 2.700 3.230 3.790

Conduit Trade Size (in.) 1/2 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4

Approx. Compound Required* Putty / Liquid SC65/SC4-KIT cc 7 7 15 23 45 68 112 175 359 536 690

A Throat Dia. (in.) 0.505 0.505 0.707 0.932 1.263 1.493 1.950 2.250 2.750 3.280 3.840

B Overall (in.) 1.870 1.870 2.140 2.270 2.750 3.000 3.200 3.800 3.860 4.100 4.000

C Dim. (in.) 1.625 1.625 2.075 2.290 2.840 3.275 3.640 4.000 4.690 5.220 5.630

C Retainer

Sealing compound not included with HLT-series. Order separately. SC65 putty supplied with each TC-series fitting. SC4-Kit liquid sealing compound not approved for use with TC-series. TC-series is suitable for use with tray cable only and cannot be used with conduit. Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. Steel: HLT-series is also available in steel. Add the suffix "S" to the catalogue number (example HLT050S). Certifications Type HLA. CSA Certified Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G; Class III, Division 2, Enclosure Type 4 SL (integral seal). CSA File 23086.

Sealing Compounds
Cat. No. Description Volume (cubic centimeter)

Hub

With bushing SC4-KIT

Liquid type sealing compound (includes pouch of sealing compound with integral spout, fiber and damming material).

66 cc

Use SC4-KIT liquid compound for shielded cables.


Cat. No. Description Volume (cubic centimeter)

SC65 SC4-KIT

Putty type sealing compound (cut-to-length stick)

34 cc

Suitable for use on cables with a maximum of four conductors (including ground). We do not recommend SC65 for use with shielded cables. Quantity of compound required will vary according to cable conductor fill.

SC65 For more details, refer to the installation/ Instruction sheet.

U.L. File No. E-82038 CSA File No. LR-23086


Note - Thomas & Betts hazardous locations fittings with integral seals (STX, STEX, HLT and TC series) are UL and CSA certified only when used with SC4-KIT or SC65 sealing compounds. No other sealing compounds have been tested, certified or listed.

28

Silver Grip TCF Series

Maximum Opening

TCF Series Tray / Cord Fitting

Gland Nut

Ordering Information
Catalogue Number Hub Size NPT 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 3 3 3 Throat Diameter (in.) 0.330 0.540 0.540 0.540* 0.540* 0.540 0.540 0.780 0.780 0.765* 0.980 0.980 0.980* 0.980 1.255 1.255* 1.255* 1.470 1.470 1.470* 1.896 1.896 2.062* 2.466* 2.780 3.050 3.068* Minimum Cable Dia. (in.) 0.150 0.250 0.400 0.540 0.660 0.250 0.400 0.540 0.660 0.770 0.660 0.770 0.870 0.940 0.890 1.080 1.270 0.890 1.140 1.390 1.190 1.520 1.850 2.120 2.380 2.640 2.900 Maximum Opening (in.) 0.270 0.400 0.540 0.670 0.780 0.400 0.540 0.670 0.780 0.880 0.780 0.880 1.000 1.090 1.090 1.280 1.470 1.150 1.400 1.650 1.530 1.860 2.190 2.520 2.780 3.040 3.300

Chuck Grip

Bushing

Body

O-Ring

TCF050-27AL TCF050-40AL TCF050-54AL TCF050-67AL TCF050-78AL TCF075-40AL TCF075-54AL TCF075-67AL TCF075-78AL TCF075-88AL TCF100-78AL TCF100-88AL TCF100-100AL TCF100-109AL TCF125-109AL TCF125-128AL TCF125-147AL TCF150-115AL TCF150-140AL TCF150-165AL TCF200-153AL TCF200-186AL TCF200-219AL TCF250-252AL TCF300-278AL TCF300-304AL TCF300-330AL

* When cord will not fit through body, strip cord jacket and trim fillers if required. Insert cable ensuring the outer jacket reaches the end of the bushing as shown. Tighten gland nut onto body.

Applications

For stainless steel (316), replace AL for SS6 (up to 1 only)

Tray Cable Complies with IEC requirements for Class I, Zone 2 locations when used with enclosures containing no arcing or sparking devices. For enclosures with arcing or sparking devices, TCF fittings must be used in combination with a certified Class I hazardous location sealing fitting. Portable Cord Complies with IEC requirements for Class I, Zone 1 locations when used with enclosures containing no arcing or sparking devices. For enclosures with arcing or sparking devices, TCF fittings must be used in combination with a certified Class I hazardous location sealing fitting.
File Number LR4484, Certificate Number 1388229 C CSA Class 4418-05 Fittings for Hazardous Locations Class I, Zone 1 Ex e II, IP66; Type 4/4X, (CSA) CSAus Class 4418-85 Fittings for Hazardous Locations Class I, Zone 1, A Ex e II, IP66; Type 4/4X, (CSAus) N.B.: Tray cable is not suitable for use in Zone 1 locations. Portable cord can be used in Zone 1 applications only when installed on portable equipment. Utilisation For use with unarmored cable Types suitable for use in Class I, Zone i (e.g.) Extra Hard Usage Cord) Series TCF Cable Glands, when used with Tray Cables are suitable to be installed in Class I, Zone 2/Div. 2 Classified Hazardous Locations Areas according to CEC/NEC Wiring Method, or subject to Local Inspection Authority having jurisdiction.
US

29

Accessories
Fitting Selectors
Identifying the correct fitting is made easy with Thomas & Betts fitting selectors. Whether for use with power, instrumentation or data transmission cables, simply align the selector with the cable brand, voltage and gauge being used and the appropriate StarTeck fitting catalogue numbers are identified in the selector window. Two selectors are currently available through your local electrical distributor or Thomas & Betts Regional Sales Office: StarTeck (ST) Series and StarTeck XP (STX) Series Selector StarTeck Extreme (STE) Series and StarTeck Extreme XP (STEX) Series Selector Cat. No.: STARTECK REG (Blue) (ST) & (STX) Series Cat. No.: STARTECK EXT (Red) (STE) & (STEX) Series

Fitting Scales
These wrap-around belt scales allow end-users to match cable to fitting on site, quickly and easily. The belts wrap around the circumference of the cable, clearly identifying the appropriate size(s) of fitting to use. The belt also incorporates a strip length gauge that indicates the correct length of armor to expose for proper grounding. The belt scales are available through your local electrical distributor or Thomas & Betts Regional Sales Office.

Cat. No.: STARTECK RULER Cat. No.: 2520 RULER Cat. No.: HLT RULER

New! New!

To acquire the above items, contact your Regional Sales Office.

30

Alphanumeric Index
Catalogue Number Page Catalogue Number Page Catalogue Number Page

10000 ................................................27 10000AL............................................27 10001 ................................................27 10001AL............................................27 10002 ................................................27 10002AL............................................27 10003 ................................................27 10003AL............................................27 10004 ................................................27 10004AL............................................27 10005 ................................................27 10005AL............................................27 10462 ................................................26 10464 ................................................26 10465-TB ..........................................26 10466 ................................................26 10467 ................................................26 10468 ................................................26 10469 ................................................26 10470 ................................................26 10471 ................................................26 10472 ................................................26 10473 ................................................26 10474 ................................................26 10475 ................................................26 10476 ................................................26 10477 ................................................26 10478 ................................................26 10479 ................................................26 10480 ................................................26 10481 ................................................26 10482 ................................................26 10483 ................................................26 10484 ................................................26 10485 ................................................26 10486 ................................................26 10550 ................................................26 10551 ................................................26 10552 ................................................26 10553 ................................................26 10554 ................................................26 10555................................................26 10601................................................27 10602-TB ..........................................27 10603................................................27 10604-TB ..........................................27 10605 ................................................27 10606-TB ..........................................27 4-250TC............................................28 4-300TC............................................28 4-350TC............................................28 4-400TC............................................28 GRL-LUG1/4-20 ...............................21 GRL-LUG1032 ..................................21 HLT050..............................................28 HLT050DATA ....................................28 HLT075..............................................28

HLT100 .............................................28 HLT125..............................................28 HLT150..............................................28 HLT200 .............................................28 L050GRL...........................................21 L075GRL...........................................21 L100GRL...........................................21 L125GRL...........................................21 L150GRL...........................................21 L250GRL...........................................21 L300GRL...........................................21 L350GRL...........................................21 L400GRL...........................................21 L500GRL...........................................21 L600GRL...........................................21 SC4-KIT ................................17, 25, 28 SC65 .....................................17, 25, 28 ST038-461S......................................15 ST050-462 ........................................15 ST050-464 ........................................15 ST050-465 ........................................15 ST050-466 ........................................15 ST075-467 ........................................15 ST075-468 ........................................15 ST100-469 ........................................15 ST125-470 ........................................15 ST125-471 ........................................15 ST125-550 ........................................15 ST150-472 ........................................15 ST150-473 ........................................15 ST200-474 ........................................15 ST200-475 ........................................15 ST200-476 ........................................15 ST200-551 ........................................15 ST250-477 ........................................15 ST250-478 ........................................15 ST300-479 ........................................15 ST300-480 ........................................15 ST300-481 ........................................15 ST350-482 ........................................15 ST350-483 ........................................15 ST400-484 ........................................15 ST400-485 ........................................15 ST400-486 ........................................15 STE050 .............................................19 STE050-DATA .............................19, 21 STE050-DATAGRL ............................21 STE050GR ........................................21 STE050GRL ......................................21 STE075 .............................................19 STE075GR ........................................21 STE075GRL ......................................21 STE100 .............................................19 STE100GR ........................................21 STE100GRL ......................................21 STE125 .............................................19 STE125GR ........................................21

STE125GRL ......................................21 STE150 .............................................19 STE150GR ........................................21 STE150GRL ......................................21 STE200 .............................................19 STE200GR ........................................21 STE200GRL ......................................21 STE250 .............................................19 STE250GR ........................................21 STE250GRL ......................................21 STE300 .............................................19 STE300GR ........................................21 STE300GRL ......................................21 STE350 .............................................19 STE350GR ........................................21 STE350GRL ......................................21 STE400 .............................................19 STE400GR ........................................21 STE400GRL ......................................21 STED050...........................................23 STED075...........................................23 STEX075 ...........................................25 STEX100 ...........................................25 STEX125 ...........................................25 STEX150 ...........................................25 STEX200 ...........................................25 STEX250 ...........................................25 STEX300 ...........................................25 STEX350 ...........................................25 STEX400 ...........................................25 STX050-462 ................................17, 25 STX050-464 ................................17, 25 STX075-465 ......................................17 STX075-466 ......................................17 STX100-467 ......................................17 STX100-468 ......................................17 STX125-469 ......................................17 STX150-470 ......................................17 STX150-471 ......................................17 STX150-550 ......................................17 STX200-472 ......................................17 STX200-473 ......................................17 STX200-474 ......................................17 STX250-475 ......................................17 STX250-476 ......................................17 STX300-478 ......................................17 STX300-479 ......................................17 STX350-480 ......................................17 STX350-481 ......................................17 STX400-482 ......................................17 STX400-483 ......................................17 STX400-484 ......................................17 STX400-485 ......................................17 TCF050-27AL ...................................29 TCF050-40AL ...................................29 TCF050-54AL ...................................29 TCF050-67AL ...................................29

31

Alphanumeric Index
Catalogue Number Page

TCF050-78AL ...................................29 TCF075-40AL ...................................29 TCF075-54AL ...................................29 TCF075-67AL ...................................29 TCF075-78AL ...................................29 TCF075-88AL ...................................29 TCF100-78AL ...................................29 TCF100-88AL ...................................29 TCF100-100AL .................................29 TCF100-109AL .................................29 TCF125-109AL .................................29 TCF125-128AL .................................29 TCF125-147AL .................................29 TCF150-115AL .................................29 TCF150-140AL .................................29 TCF150-165AL .................................29 TCF200-153AL .................................29 TCF200-186AL .................................29 TCF200-219AL .................................29 TCF250-252AL .................................29 TCF300-278AL .................................29 TCF300-304AL .................................29 TCF300-330AL .................................30

*Trademark note: NFPA is a registered trademark of National Fire Protection, Inc.

32

Notes

33

Notes

34

Notes

35

Notes

36

You might also like