You are on page 1of 5

Sole distributor ROUTE DU LOIR / F-13250 SAINT CHAMAS TEL. +33 (0)4 90 44 36 10 / FAX.

+33 (0)4 90 44 36 11

www.armaturis.com

FTCen/1-1 09/11/2012

The Firsty range of couplers is the economical solution of the Hrisson range A rebar coupler is more resistant than the bar itself
The coupler always breaks along the bar during destructive tests.

Manufactured in large quantities, the Firsty coupler, with its simple form, oers a highperformance and aordable constructive system.

A rebar coupler fully compliant with the standards and commendations Rebar threading
Threading is achieved following cold upsetting of the rebar ends to increase the nominal diameter. Threading by rolling maintains the steel fibres, which ensure the coupler has excellent resistance. Rebar resistance is therefore not affected by the threading operation.
specific geometry design (ISO Screw Threads) specific patented machinery strict inspections specialised workshops 1. 2. 3. 4.
Cold upsetting Rough turning Thread rolling

Rolled thread fibre maintained

Machined thread fibre broken

Quality assurance

A fabrication process under continuous monitoring compounded by simple and reliable assembly procedures ensure the high quality and safety of our rebar couplers, from fabrication to installation.

Sole distributor ROUTE DU LOIR / F-13250 SAINT CHAMAS TEL. +33 (0)4 90 44 36 10 / FAX. +33 (0)4 90 44 36 11

www.armaturis.com

FTCen/1-2 09/11/2012

Sole distributor ROUTE DU LOIR / F-13250 SAINT CHAMAS TEL. +33 (0)4 90 44 36 10 / FAX. +33 (0)4 90 44 36 11

www.armaturis.com

FTCen/1-3 09/11/2012

The range

Firsty
D

Firsty coupler specifications


12

16 44,50 26,50
CFI16

20 52,85 32,50
CFI20

25 65,65 40,50
CFI25

32 77,50 50,50
CFI32

40 96,50 60,50
CFI40

B=coupler length (mm) 36,00 D=overall diameter (mm) 19,50 Description CFI12 Colour codes*

* used on locknut wrenches, checking tools, thread protection, etc.

Firsty coupler

Sole distributor ROUTE DU LOIR / F-13250 SAINT CHAMAS TEL. +33 (0)4 90 44 36 10 / FAX. +33 (0)4 90 44 36 11

www.armaturis.com

FTCen/1-4 09/11/2012

Standard assembly
Installation
Step 1:
if required

The 2nd phase rebar can be screwed in Inspection

1st phase installation

Fastening accessory

X The cap is correctly in place on the coupler.

1st phase concreting


Remove thread
protecting caps

Step 2:

put 2nd phase rebar in position

Step 3:
Screw in by hand

screw on 2nd phase rebar


(a wrench can be used to facilitate the operation)

Step 4: locking the liaison


Using the wrench, to lock rebar

X For dia. 25 and greater: L 0.80 m.


At this stage of assembly the Firsty rebar coupler guarantees the safety of the liaison.

Sole distributor ROUTE DU LOIR / F-13250 SAINT CHAMAS TEL. +33 (0)4 90 44 36 10 / FAX. +33 (0)4 90 44 36 11

www.armaturis.com

FTCen/1-5 09/11/2012