SIMATIC Welcome to WinAC MP 2008 Update 4

This Readme file contains important information for current product deficiencies that are corrected by WinAC MP 2008 Update 4. Please read this information before you install and operate the software. This Update is cumulative; it also includes the corrections of previous Updates. Before installing the WinAC MP 2008 Update 4 software, ensure that WinCC flexible 2008 SP1 and WinAC MP 2008 are already installed on your engineering system. When Update is installed on your engineering system, you will need to transfer the runtime files of the WinAC MP 2008 option to the multi panels of type MP 177, MP 277 or MP 377 (incl. DayLight). If the option was already installed on a multi panel MP 177, MP 277 or MP 377 (incl. DayLight), it must be uninstalled before Update 4 transfer. Note: If additional languages are installed on the engineering system after installation of Update 4 of the WinAC MP 2008 option, a reinstallation of Update 4 will be required. The following behaviour is corrected by WinAC MP 2008 Update 4: With the current Service Pack 3 of WinCC flexible 2008, the system functions of WinAC MP 2008 Update 3 are no longer supported. With Update 4, you will again be able to use the WinAC MP system functions without restriction. Use of the WinAC MP system functions with WinCC flexible 2008 SP3 If you wish to migrate a user program from WinCC flexible 2008 SP2 to WinCC flexible 2008 SP3 in order to use it with WinAC MP , follow these steps: 1. Remove WinAC MP 2008. 2. Install WinCC flexible 2008 SP3 3. Install WinAC MP 2008. 4. Install Update 4 for WinAC MP 2008 5. Migrate the user program from WinCC flexible 2008 SP2 to WinCC flexible 2008 SP3 Result All WinAC MP system functions are now also available to their full extent with the migrated project.

SIMATIC Welcome to WinAC MP 2008 Update 3

This Readme file contains important information for current product deficiencies that are corrected by WinAC MP 2008 Update 3. Please read this information before you install and operate the software. This Update is cumulative; it also includes the corrections of previous Updates. Before installing the WinAC MP 2008 Update 3 software, ensure that WinCC flexible 2008 SP1 and WinAC MP 2008 are already installed on your engineering system. When Update is installed on your engineering system, you will need to transfer the runtime files of the WinAC MP 2008 option to the multi panels of type MP 177, MP 277 or MP 377. If the option was already installed on a multi panel MP 177, MP 277 or MP 377, it must be deinstalled before Update 3 transfer. Note: If additional languages are installed on the engineering system after installation of Update 3 of the WinAC MP 2008 option, a reinstallation of Update 3 will be required. The following behaviour is corrected by WinAC MP 2008 Update 3: If several external communication partners were sending a connection request at the same time when starting up WinAC MP 2008, it did happen sporadically that not all connections could be established. During startup of WinAC MP in connection with PROFIBUS DP communication, it could happen in rare cases that the loaded STEP 7 user program was not recognized. Due to an improvement in PROFIBUS DP communication, this behavior no longer occurs.

Security information:
Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you keep yourself informed about updates and upgrades for our products and always use the latest version of each product. You can find information on this at: http://support.automation.siemens.com. You can register for a product-specific newsletter here. For the safe operation of a plant/machine, however, it is also necessary to integrate the automation components into an overall IT security concept for the entire plant/machine, which corresponds to the state-of-the-art IT technology. You can find information on this at: http://www.siemens.com/industrialsecurity. Products used from other manufacturers should also be taken into account here.

Notes on installation Notes on Use Customer Service

1 2 3

SIMATIC Welcome to WinAC MP 2008


Readme

04/2009

Legal information Warning notice system


This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

Proper use of Siemens products


Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed.

Trademarks
All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG Industry Sector Postfach 48 48 90026 NRNBERG GERMANY

2012

Copyright Siemens AG 2009. Technical data subject to change

Table of contents
1 Notes on installation .................................................................................................................................. 5 1.1 1.2 1.3 1.4 1.4.1 1.4.2 2 2.1 2.2 3 Scope of delivery ...........................................................................................................................5 Additions to the Certificate of License ...........................................................................................6 Hardware and software requirements............................................................................................6 Installation ......................................................................................................................................8 Installing WinAC MP 2008 .............................................................................................................8 Uninstalling WinAC MP 2008.........................................................................................................9 Essential system characteristics of WinAC MP 2008 ..................................................................11 Notes on configuration and operation..........................................................................................12

Notes on Use........................................................................................................................................... 11

Customer Service .................................................................................................................................... 15

Welcome to WinAC MP 2008 Readme, 04/2009

Table of contents

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation

1.1 Scope of delivery


Overview of the components supplied
The following components ship with the product: CD with: WinAC MP 2008 Electronic operating instructions in PDF format Languages: German, English, French USB stick with: Single license for WinAC MP 2008 Software Product (Certificate of License)
CAUTION

The USB Memory Stick on which the license keys are delivered is intended and released exclusively for the transport of license keys between configuration computers. The USB Memory Stick is not released for use with SIMATIC HMI Panels (e.g. backup/restore, archiving).

WinCC flexible System Library


The WinAC MP scope of delivery includes a WinCC flexible system library that contains two screens. These screens are taken over during the installation in the WinCC flexible system library and are available for use there. The WinCC flexible system library includes the following Screens: Home Screen Tuning Screen

Further Information
The following sections of the manual provide you with a detailed description of the screens: Description of the Home Screen Description of the Tuning Screen

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation 1.2 Additions to the Certificate of License

1.2 Additions to the Certificate of License


Additions to the Certificate of License
The Certificate of License is part of the contract governing the use of software products for a one-time fee included in the scope of delivery. The Certificate of License includes a list of the licensed software components and their warranty classes. The customer is not authorized to modify the software during the term of the contract. Please indicate the Certificate of License code on any correspondence.

1.3 Hardware and software requirements


Installation sequence
To be able to use WinAC MP on the HMI device, it is mandatory that you keep to the following sequence during installation on the configuration PC: 1. Install STEP 7 V5.4 SP 4 or higher 2. Install WinCC flexible 2008 SP1 3. Install WinAC MP 2008 Tip If older versions of STEP7, WinCC flexible and WinAC MP have already been installed, you will have to uninstall them first. Once the programs have been uninstalled, you will have to observe the installation sequence listed above.

HMI device hardware requirements


WinAC MP is installed on a reserved area of the flash memory. The memory area reserved for HMI applications is not reduced by this. WinAC MP runs on the following HMI devices: SIMATIC MP 177 6" Touch (6AV6 642-0EA01-3AX0) SIMATIC MP 277 8" Touch (6AV6 643-0CB01-1AX1) SIMATIC MP 277 8" Key (6AV6 643-0DB01-1AX1) SIMATIC MP 277 10" Touch (6AV6 643-0CD01-1AX1) SIMATIC MP 277 10" Key (6AV6 643-0DD01-1AX1) SIMATIC MP 377 12" Touch (6AV6 644-0AA01-2AX0) SIMATIC MP 377 12" Key (6AV6 644-0BA01-2AX0)

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation 1.3 Hardware and software requirements


SIMATIC MP 377 15" Touch (6AV6 644-0AB01-2AX0) SIMATIC MP 377 15" Touch DayLight readable (6AV6 644-8AB20-0AA1) SIMATIC MP 377 19" Touch (6AV6 644-0AC01-2AX0) To find out if successor Multi Panels are supported, refer to the Internet (http://www.siemens.com/automation/service&support).

HMI device software requirements


To install WinAC MP 2008 on the HMI device, you require: WinCC flexible runtime 2008 SP1 current image of the HMI device from WinCC flexible 2008 SP1 Notes on updating the HMI device image are available in the respective documentation.

Configuration PC hardware requirements


To install WinAC MP on the configuration PC, you require At least 40 MB of free space on the hard disk The requirements of STEP 7 and WinCC flexible must also be supported

Configuration PC software requirements


To install WinAC MP on the configuration PC, you require Microsoft Windows XP Professional, Service Pack 2 or higher STEP 7 V 5.4 with Service Pack 4 or higher WinCC flexible 2008 SP1

And...
You need: An Ethernet or PROFIBUS connection between the configuration PC and HMI device or a Serial RS232/PPI Multi Master cable for serial transfer (for example to load the MP 177 and MP 277 the first time) between the configuration PC and HMI device (order no. of the cable: 6ES7 9013CB30-0XA0). SIMATIC NET if you want to use Ethernet communication (SIMATIC NET CD V7.0 or V7.1). Devices necessary for process control connected to your HMI device using PROFIBUS DP (for example, ET 200). The Adobe Reader, to read the supplied electronic manuals. You can obtain the latest version of Acrobat Reader at www .Adobe.com.

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation 1.4 Installation

1.4 Installation
1.4.1 Installing WinAC MP 2008

Requirements
Prior to installing WinAC MP, pay attention to the hardware and software requirements. Note You must first uninstall any already installed WinAC MP version.

Installing WinAC MP on the configuration PC


The WinAC MP software includes a setup program that automatically performs the installation. The installation program leads you step by step through the installation operation. You can go to the next step or back to the previous step at any time. To start the installation program, proceed as follows: 1. Insert the CD "WinAC MP 2008" in the CD drive of your configuration computer. 2. Double-click on the "setup.exe" file in the "\WinAC" folder. 3. Follow the instructions until the following screen appears:

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation 1.4 Installation


4. Confirm the dialog and follow the instructions on the screen. Result: A message is displayed when the installation has been completed successfully. 5. You should restart your computer after the installation has completed.

Installing WinAC MP 2008 on the HMI device


1. Installing the options with ProSave. 2. Installing the product-specific license (license key) with the Automation Single License Manager.

1.4.2

Uninstalling WinAC MP 2008

Uninstalling WinAC MP 2008


The WinAC MP 2008 Operating Instructions contain information about uninstalling: WinAC MP 2008 on the HMI device The license key on the HMI device WinAC MP 2008 on the configuration computer

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on installation 1.4 Installation

10

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on Use

2.1 Essential system characteristics of WinAC MP 2008


New software PLC WinAC MP 177 for MP 177 6'' Touch Improved time behavior through conversion to "HMI Enable Time" With WinAC MP, you can configure retentive data for bit memory, S7 timers, S7 counters and data blocks. Even if there is a power down while WinAC MP is running, the current values of the retentive DBs or bit memory, timers and counters are not lost. When you restart WinAC MP again, you can access the last saved values of these retentive memory bits, timers, counters and DBs. B-Send / B-Receive now available in WinAC MP 2008. The performance during online monitoring via PROFINET has been improved for WinAC MP 2008. New screen forms integrated into WinCC flexible system library. A new parameter has been added in WinAC MP 2008 to specify the file path for system functions Archive and Restore. WinAC MP supports time synchronization between the HMI device and the WinAC MP installed on it. Routing with S7 communication is possible with WinAC MP. You configure WinAC MP in STEP 7 as an HMI station and not as a PC station. WinAC MP supports only the OB 35 as cyclic interrupt. Expansion of the IO address area from 2k to 4k for MP 277 SCL / CFC programming Additional technical specifications are available in the in the section "Technical specifications" in the operating instructions for WinAC MP 2008.

Welcome to WinAC MP 2008 Readme, 04/2009

11

Notes on Use 2.2 Notes on configuration and operation

2.2 Notes on configuration and operation


Notes on configuration and operation
1. Changing a program that uses S7 program block communication. If you change the SFBs for point-to-point communication (SFB8/SFB9, SFB12/SFB13 and SFB14/SFB15) or the instance DBs for these SFBs, you must always download the complete program, including DBs, to all affected CPUs. Do not download just the SFB or the DB. 2. The entry in the diagnostic buffer "Time of-day interrupt(s) skipped due to new clock setting" (event ID 16#3505) shows up when the time is changed or replaced with the event 16#35A1 "User interface (OB 10) not found". You determine the sequence of events based on the time stamps. When OB10 (time-of-day interrupt) is enabled and the time of the WinAC MP 2008 control engine is put forward so that the start time of OB10 has been skipped, OB10 executes immediately. In this case, the above event ID 16#3505 is entered in the diagnostic buffer. This entry is not always made, however. 3. The time functions of the WinAC MP operate at a resolution of one millisecond [ms]. As a result of this and the internal processing times, the specified wait time on SFC 47 can be delayed up to 1 ms. 4. When a memory reset is performed on a large program, the online connection may be lost in STEP 7. Nevertheless, the complete memory reset is carried out. After the memory reset, WinAC MP can be reached online again with STEP 7. This can take several minutes. 5. The following language settings have been released on the configuration computer: German, English UK, English US, French, Spanish, Italian Chinese (Chinese simplified) and Taiwanese (Chinese traditional) Japanese and Korean All other languages supported by Microsoft are not released. 6. Configuring the WinAC MP update functions (for example UpdateHMIEnableTime) is permitted only once per screen. The WinAC MP update function must be configured for the "Screen loaded" event with the Action parameter "SwitchOn". The WinAC MP update function must be configured for the "Screen cleared" event with the Action parameter "SwitchOff". If a function is called more than once with different variables in one screen, only the variable activated last is updated. You should therefore only use identical variables as parameters of the functions within a screen. 7. If the "StartAtBootOn" parameter is active for the WinAC MP "SetWinACStartAtBoot" function, WinAC MP starts automatically not only after power cycling the multi panel, but also when restarting WinCC Flexible Runtime. 8. Printing with WinCC flexible system functions If WinAC MP 2008 is started on the multi panel, the delay before a print job executes is extended by approximately 30%.

12

Welcome to WinAC MP 2008 Readme, 04/2009

Notes on Use 2.2 Notes on configuration and operation


9. If you start to uninstall the WinAC MP option using ProSave and if automatic transfer detection (remote control) is active, the runtime is ended and the uninstall procedure started even if WinCC flexible Runtime has started and WinAC MP 2008 is in RUN. 10.The WinAC MP system functions "Archive" and "Restore" can only be used with S7 user programs requiring up to a maximum of 1.2 MB load memory. With S7 user programs requiring more than 1.2 MB of load memory, you have the alternative of using Backup/Restore in the "Control Panel" of the HMI device with which all data (image, WinAC MP option, S7 user program, ...) can be backed up and restored. 11.The following functions are not currently released when WinAC MP 2008 is installed on the HMI device: "Uninstalling the WinAC MP option", "Operating system update of the HMI device", backup or restore function via Teleservice, TS Adapter or direct connection with the configuration computer over PROFIBUS-DP. Backing up/restoring can be performed simply using standard storage devices * (SD, MM card or USB stick) on the HMI device itself. The content of the backup standard storage device can be compressed as a ZIP file (may be more than 10 MB) and is easy to send as an E-mail. It also presents no problem for the recipient to write the content of the ZIP file to a standard storage device (SD, MM card or USB stick). Using the restore function, a backup can therefore be restored directly on the HMI device. As an alternative to sending the file by E-mail, it can also be forwarded via an FTP server. It is also possible to execute all normal functions (backup, restore, operating system update, ...) from a configuration computer over an Ethernet connection with ProSave. * Storage devices approved by Siemens are preferable 12.If you use a DP interface module with WinAC MP 177, MP 277 or MP 377, 244 slots (regardless of the number of bytes) are released for use. If you use between 2 and 32 DP interface modules, a maximum of 30 slots (regardless of the number of bytes) are released for each DP interface module. 13.If the WinAC MP option is not yet installed on the multi panel, but a WinCC flexible runtime project has already been transferred to the multi panel with a WinAC MP Softbus connection, "automatic transfer detection" no longer works over PROFIBUS. Change to transfer mode manually or transfer a WinCC flexible Runtime project without a Softbus connection or install WinAC MP 2008 option on the HMI device. 14.The "Counter" and "Time" data types can be configured as parameters for WinAC MP functions, but are not released with WinAC MP. Use a different configurable data type (e.g. Int) as parameter of a WinAC MP system function. 15.You can download a Getting Started video for step-by-step instructions of the installation: http://support.automation.siemens.com/WW/view/en/32010673. 16.Before you transfer the WinCC flexible project and the WinCC flexible Runtime files to the HMI device, you need to install the WinAC MP option on the target device. 17.You cannot configure a routing connection from an HMI device to a SIMATIC CPU via two or more routers (such as SIMATIC HMI Station with WinAC MP) in the WinCC flexible ES Connection editor. This means a WinCC flexible Runtime connection via two or more routers will not be supported. 18.There may be limitations during operation of WinCC flexible options in case of excessive processor load of the HMI device with WinAC MP. 19.The WinCC flexible system function ChangeConnection to change an OP connection between a local WinAC and an external CPU is not supported.

Welcome to WinAC MP 2008 Readme, 04/2009

13

Notes on Use 2.2 Notes on configuration and operation


20.If you encounter overload conditions when logging large quantities of data with WinCC flexible tag or alarm logging, reduce the number of tags you want to archive or the number of data records per log or increase the logging cycle of the tags. You recognize overload conditions by the following system alarms: $80012 Logging overload Values will be lost and $80013 Overload during logging finished

Some of these system alarms may extend the runtime of the OB1 cycle.. 21.When you export a project from Step7 (CFG), the parameter "Location code" of a WinAC MP station will not be exported. 22.When you "Shutdown => Start" WinAC MP in the home screen, WinAC MP will sporadically fail to start. In this case please re-boot the unit.

14

Welcome to WinAC MP 2008 Readme, 04/2009