AIR CONDITIONER
Prior to installation, this air conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm).
IMPORTANT
Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. Please retain this owner's manual for future reference after reading it thoroughly.
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions.................3 Prior to Operation ..................6 Operating Instructions...........9 Remote Controller ..............9 Remote Control Operation....11 Additional features...............19 Maintenance and Service ....23 Operation Tips ..................24 Troubleshooting ..............25
Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
PRECAUTION
Contact the authorized service technician for repair or maintenance of this unit. Contact the installer for installation of this unit. The air conditioner is not intended for use by young children or invalids without supervision. Young children should be supervised to ensure that they do not play with the air conditioner. When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts. Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only.
2 Owner's Manual
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
WARNING CAUTION
This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage.
WARNING
Installation
Do not disassemble or repair the product.
Contact your dealer and service center.
Do not handle the flamable gas or explosive materials near the product.
Otherwise, it may cause fire or failure of product.
Owner's Manual 3
Safety Precautions
Operation
Do not touch(operate) product with wet hands.
Otherwise, it may cause fire or electric shock.
If abnormal sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable.
Otherwise, it may cause electric shock or fire.
When the product is not going to be used for a long time,disconnect the power supply plug or turn off the breaker.
Otherwise, it may cause failure of product or fire.
Do not turn the breaker on/off or connect/disconnect the power supply plug during operation.
Otherwise, it may cause fire or electric shock.
Do not touch the metal parts of the product when removing the air filter.
Otherwise, it may cause personal injury.
Take care to ensure that water could not enter into the product.
Otherwise, it may cause fire or electric shock.
CAUTION
Installation
Always inspect gas leakage after installation and repair of product.
Otherwise, it may cause failure of product.
Install the drain hose to ensure that drain can be securely done.
Otherwise, it may cause water leakage.
4 Owner's Manual
Safety Precautions
Install the product so that noise or hot wind from the outdoor unit. May not give any damage to the neighborhoods.
Otherwise, it may cause dispute with the neighborhoods.
Operation
Do not expose your skin directly to cool air for a long time.
Otherwise, it may harm to your health.
When flamable gas leakages from the product, open the window for ventilation.
Otherwise, it may cause explosion or fire.
Do not put a pet or houseplant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not use the product for special purpose to preserve animals, vegetables, precision device, or art objects, etc.
Otherwise, it may cause loss of property.
Always insert the filter securly. Clean it once every two weeks.
Otherwise, it may cause failure of the product.
Use a soft cloth to clean, Do not use wax, tinner or a strong detergent, etc.
Otherwise, it may change the apperance of the product.
Do not insert your hand or bars, etc. into the air inlet/outlet.
Otherwise, it may cause personal injury.
Do not use the product at the closed space for a long time.
Otherwise, it may cause suffocation due to poor oxygen.
Do not operate the product for a long time in high humidity, and leave a door or window open.
Otherwise, water may drop and wet or damage furniture, etc.
Do not step onto an unstable bench when maintaining the product, etc.
Otherwise, it may cause personal injury.
Do not charge or disassemble the batteries and do not throw them into a fire.
Otherwise, it may cause fire or an explosion.
If liquid from the batteries gets onto your skin or clothes, wash it well with clean water.
Otherwise it may harm to your health.
Owner's Manual 5
Prior to operation
Prior to operation
Preparing for operation
1. Contact an installation specialist for installation. 2. Connect the power cable between indoor unit and outdoor unit properly. 3. Use a dedicated circuit. 4. If the cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time. 2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices. 3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
Service
For repair and maintenance, contact your authorized service dealer.
6 Owner's Manual
Safety Precautions
Features
This appliance should be installed in accordance with national wiring regulations. This guide acts as a guide to help to explain product features.
Indoor
Air Inlet
Air Filter
Front Panel
Signal Receptor
Outdoor
Air Intake Vents Connecting Wires Piping
Owner's Manual 7
Electrical Safety
Electrical Safety
This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded oulet. Do not cut or remove the grounding prong from the power plug. Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring. If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
8 Owner's Manual
Operating Instructions
Operating Instructions
Remote Controller
ENGLISH
1 Remove the battery cover by pulling it according to the arrow
direction.
2 Insert new batteries making sure that the (+) and (-) of battery are
installed correctly.
NOTICE
Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.
To operate the room air conditioner, aim the Remote Controller to the signal receptor.
Owner's Manual 9
Operating Instructions
: Lights up during the system operation. : Lights up during Sleep Mode Auto operation. : Lights up during Timer operation. : Lights up during Defrost Mode or Hot Start operation.(Heat pump model only) : Lights up during Plasma operation. (Optional)
Plasma
Desire temperature : For cooling,dehumidification,heating modes it display desired temperature Cooling : 18~30C AI : Auto Operation indicator Dehumidification : 18~30C Po : Jet Cool Heating : 16~30C Lo : Test Mode
10 Owner's Manual
Operating Instructions
1 2 3 4
START/STOP BUTTON Operation starts when this button is pressed and stops when the button is pressed again. OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low, medium, high and CHAOS. JET COOL Used to start or stop the speed cooling/heating. (Speed cooling/heating operates super high fan speed.) CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up/down airflow direction. ON/OFF TIMER BUTTONS Used to set the time of starting and stopping operation. TIME SETTING BUTTONS Used to adjust the time. TIMER SET/CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation. SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation. AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating. ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature. PLASMA (Optional) Used to start or stop the plasma-purification function. RESET BUTTON Initialize remote controller. 2nd F Button Used prior to using modes printed in blue at the bottom of buttons. AUTO CLEAN Used to set Auto Clean mode. LED LUMINOSITY Used to control the luminosity of the display on unit HORIZONTAL AIRFLOW DIRECTION CONTROL BUTTON (NOT ON ALL MODELS) Used to set the desired horizontal airflow direction.
(Heat Pump) (Cooling Only)
ENGLISH
5 6
1 3
5 6 7 8 9 10
4 2 7 11 8 13 14
CANCEL ON OFF SET AUTO CLEAN
10 9 16 17 12 18 15
11 12 13 14 15 16 17 18
Operation Mode
Cooling Operation Auto Operation Healthy Dehumidification Operation Heating Operation
Cooling Model(
Owner's Manual 11
Operating Instructions
Cooling Operation
1 2
Press the Start/Stop button. The unit will respond with beep sound.
Open the door on the Remote Controller. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Cooling
Auto Changeover
Healthy Dehumidification
3
ON
Set the temperature lower than the room temperature. The temperature can be set within a range of 18C~30C in 1C.
To raise the temperature
You can select the fan speed in four stepslow, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Natural wind by the CHAOS logic For more fresh feeling, press the Indoor Fan Speed Selector and set CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
12 Owner's Manual
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Cooling
Auto Changeover
Healthy Dehumidification
3
ON
Close the door of the remote controller. Set the temperature lower than the room temperature. The temperature can be set within a range of 18C~30C at intervals of 1C.
To raise the temperature
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
During Auto changeover Operation The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over 2 C with respect to setting temperature, air conditioner keeps the room temperature within 2C with respect to setting temperature by auto changeover mode.
Owner's Manual 13
Operating Instructions
1 2
Press the Start/Stop button. The unit will respond with beep sound.
Open the door on the Remote Controller. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Cooling
Auto Changeover
3
ON
Set the fan speed. You can select the fan speed in four steps - low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
DURING HEALTHY DEHUMIDIFICATION OPERATION: If you select the dehumidification mode on the operation selection button, the A/C starts to run the dehumidification function, automatically setting the room temp. and air volume to the best condition for dehumidification based on the sensed room temp. In this case, the setting temp. is not displayed in the Remote Controller and you are not able to control the room temp. either. During the healthy dehumidification function, the air volume is automatically set according to the algorithm responding to the current room temp. and makes the room condition healthy and comfortable even in the high humidity season.
14 Owner's Manual
Operating Instructions
Open the door on the Remote Controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Cooling
Auto Changeover
Healthy Dehumidification
3
ON
Set the temperature higher than the room temperature. The temperature can be set within a range of 16C~30C in 1C.
To raise the temperature
Set the fan speed again. You can select the fan speed in four stepslow, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Owner's Manual 15
Operating Instructions
Jet Cool
Press the Start/Stop button. The unit will respond with beep sound.
Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button or the fan button or the room temperature setting button again and the unit will operate in high fan speed in cooling mode
or
or
NOTICE
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp. automatically to 18C. It is especially used to cool the room temperature in the shortest time. In order to return to the normal cooling mode from the Jet Cool mode, you just press either the operation mode selection button, air volume selection or temp. setting button or the JET COOL button again.
16 Owner's Manual
Operating Instructions
Open the door on the Remote Controller. Press the PLASMA air purifying operation ON/OFF button. Operation will start when the button is pressed and stop when the button is pressed again.
Set the fan speed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted. Air purifying operation (PLASMA) is available in Heating or any other operations.
Owner's Manual 17
Operating Instructions
2nd F Operation
Press the Start/Stop button. The unit will respond with beep sound.
Open the door of the Remote Controller and press the 2nd F button to operate functions printed in blue at bottom of buttons. (Check the indication of 2nd function on Remote Controller display.) These buttons operate the timer setting as follows:
CANCEL ON OFF SET AUTO CLEAN
2nd function goes off in a short time automatically or when the button is pressed again.
18 Owner's Manual
Operating Instructions
Additional features
Sleep Mode
1. Press the Sleep Mode Auto button to set the time you want the unit to turn off automatically. 1. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner. 3. Make sure the Sleep Mode Auto LED lights up. To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star ( ) disappears from the operation display.
NOTICE The Sleep Mode will be operated at low fan speed (cooling) or medium fan speed (heat pump only) for quiet sleeping.
IN COOLING MODE: The temperature will automatically rise by 1C over the next 30 minutes and by 2C in 1 hour for comfortable sleeping.
CANCEL
SET
5. Press the selected on/off setting by pressing the Timer SET button while aiming the Remote Controller at the signal receptor.
CANCEL SET
To cancel the setting the timer. Press the Timer Cancel button while CANCEL aiming Remote Controller at the signal SET receptor. (The timer lamp on the air conditioner and the display will go out.)
NOTICE
Select one of the following four types of operation. with the unit running
Delay ON Timer
Owner's Manual 19
Additional features
(Vertical Airflow) can be adjusted by using the Remote Controller. Press the Start/Stop button to start the unit. Open the door on the Remote Controller. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction. Press Chaos Swing button and the louvers will swing.
Press the button again and the louvers will stop. After 30 minutes, the louvers return to the maximum airflow position automatically.
20 Owner's Manual
CHAOS Air
NOTICE
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically
changed from high to low or vice versa, depending on the ambient temperature.
Auto Clean
1. Press the Start/Stop button to Start the unit. 2. Open the door on the Remote Controller Select Cooling Operation or Healthy Dehumidification Operation. 3. Press the Auto clean button. 4. Although the Start/Stop button is pressed, unit operates in Auto clean Mode for 15 minutes - operates in heating operation Mode for 1 minute and circulates the room air without cooling and heating for 14 minutes. And then unit stops operating. NOTE: During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed. During Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available.
AUTO CLEAN
Display Luminosity
AUTO CLEAN
The Display Luminosity of the unit can be adjusted by using the Remote Controller. Press the start/stop button to start the unit. Open the door on the Remote Controller, press the 2nd F button and, press display luminosity button. Display will be dark. Press the button again to set bright display.
Owner's Manual 21
Additional features
Forced Operation
ENGLISH
The operation will be started if the power button is pressed without remote controller. If you want to stop operation, re-press the button.
Cooling Model Operating mode Indoor FAN Speed Setting Temperature Cooling High 22C
Heat pump Model Room Temp. 24C Cooling High 22C 21C Room Temp. < 24C Healthy Dehumidification High 23C Room Temp. < 21C Heating High 24C
Auto restart
In case the power comes on again after a power failure, the unit operates automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts about 3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode. In case of absence for a long time while power failure, turn off main power to avoid undesired Auto restart.
Helpful information
Fan speed and cooling capacity. The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool/heat the room quickly.
High d Spee
22 Owner's Manual
NOTICE Supply power must be disconnected before cleaning the indoor unit.
AIR FILTERS
The air filters behind the front grille should be checked and cleaned once in every 2 weeks or more often if neccessary. 1. Open the front panel as shown. 2. Then pull the filter tab slightly forward to remove the air filter. 3. Clean the filter with a vacuum cleaner or warm, soapy water. If dirt is conspicuous, wash with a solution of detergent in lukewarm water. If hot water (40C or more) is used, it may be deformed. 4. After washing with water, dry well in the shade. 5. Re-install the air filter.
Front panel
CAUTION
Never use any of the followings: Water hotter than 40C Could cause deformation and/or discoloration. Volatile substances Could damage the surfaces of the air conditioner.
Pow
d er
G a s o li n e
Owner's Manual 23
When the air conditioner is not going to be used for a long time.
When air conditioner is not going to be used for a long time. When the air conditioner is to be used again.
ENGLISH
Operate the air conditioner on Air circulation mode (Refer to page 21) for 2 to 3 hours. This will dry out the internal mechanisms. Turn off the circuit breaker, and disconnect the power cable.
Clean the air filter and install it in the indoor unit. (Refer to page 23 for cleaning filters.)
Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Operation Tips
Do not overcool the room. Keep blinds or curtains closed. Keep the room temperature uniform.
Do not let direct sunshine enter the room when the air conditioner is in operation.
Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.
Make sure that the doors and windows are shut tight. Avoid opening doors and windows if possible to keep the cool air in the room.
Ventilate the room occasionally. Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.
Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.
24 Owner's Manual
Troubleshooting
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer or service center.
Case
The air conditioner does not operate. The room has a peculiar odor.
Explanation
Check room temperature setting? Check if circuit breaker is on? Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room. Check the drain hose is connected tight or if indoor unit is installed even.
See page
12,15 -
It seems that condensation is leaking from the air conditioner. Air conditioner does not operate for about 3 minutes after turning on.
This is the protector of the mechanism. Wait about 3 minutes and operation will begin. About 3 minutes delay is applied to protect compressor from frequenty on/off.
Is the air filter dirty? See air filter cleaning instructions. Has the temperature been set correctly? Are the indoor unit's air inlet or outlet vents obstructed?
23 12,15 -
For a noise that sounds like water flowing. -This is the sound of refrigerant flowing inside the air conditioner unit. For a noise that sounds like the compressed air releasing into atmosphere. -This is the sound of the dehumidifying water being processed inside the air conditioning unit. Are the batteries depleted? Are the batteries inserted in the opposite (+) and (-) directions? This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature.
Owner's Manual 25