Electrical Test and Maintenance of Transformers, Relays and Circuit Breakers


Transformer Service, Inc. has been a leader in improving transformer and switchgear reliability and performance since 1952. TSI has developed preventive maintenance strategies that identify and cure potential problems before they affect operation or longevity. The cornerstones of TSIs preventive program are oil sampling, electrical test and visual inspection. Together, these three methods provide the information to analyze the condition of your transformer and switchgear and to determine the steps needed to assure reliability and top performance.

Electrical Testing
Electrical tests accurately measure these important values: Insulating value of insulation (DC Megger) Resistive and Capacitive loss (DC Hipot) Power Factor (tests of transformers & bushings) Relationship of primary and secondary voltages (TTR) Trip levels and accuracy of relays and low, medium and high voltage circuit breakers Test results are compared to manufacturers specifications and/or performance standards set by NETA, IEEE and NEMA, and establish a baseline for comparison with future tests. Repairs or calibration needed to bring equipment into specification can be easily identified, and post repair testing assures that proper corrective action has been taken. In many cases, testing identifies the need for simple repairs and adjustments that preclude costly repairs and downtime in the future.

Tests Performed
The suite of tests include the following: Dielectric Absorption Insulation resistance test, winding-to-winding and winding-to-ground. Turn to Turn Ratio Test: to determine actual vs. calculated voltage Power Factor Test: to assess condition of electrical insulation in high voltage apparatus Breaker and relay tests of contact resistance, conductivity, insulation resistance, current and /or voltage trip levels

Equipment Used
Microprocessor based circuit breaker test sets for high current injection 5KV Insulation Resistance testers Automated Insulation Power Factor Test Set Protective Relay Test Set Digital Low Resistance Ohmmeters 10KV automated power factor test set Turn to Turn Ratio Test Set

Repairs
Our breaker and relay test process compares the performance of your equipment to manufacturers maintenance specifications. In addition to testing, our technicians perform on-the-spot repairs such as: Cleaning cubicles Burnishing and adjusting contacts Lubricating moving parts Retrofitting trip units Repairing faulty subassemblies More extensive repairs are performed by returning the faulty item to TSI or on a subsequent site visit.

1 of 2

http://www.transformer-svc.com/electrical_testing.htm
l

Test Report and Analysis


After the test program is completed, a test report is compiled and submitted to our customer. The test report presents the actual data taken at the customers site and the results of any calculated values. Out of specification conditions are highlighted and maintenance recommendations are presented.