You are on page 1of 8

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202056 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

2.3/8-5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

NL 0147586

Left Ear Diameter: 7/8 Right Ear Diameter: 7/8 Top Bore Diameter: 7 Bottom Bore Diameter: 5.1/2 Door Gap: 3/16 Hinge Gap: 1/4" SWL: 5 Tons Manufacturer: VARCO BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202057 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

2.3/8-5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

NL 0147587

Left Ear Diameter: 7/8 Right Ear Diameter: 7/8 Top Bore Diameter: 7 Bottom Bore Diameter: 5.1/2 Door Gap: 1/4 Hinge Gap: 1/4" SWL: 5 Tons Manufacturer: VARCO BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202058 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

8.5/8- 10.3/4 OD SINGLE JOINT ELEVATOR

DIMENSIONS

12671

Left Ear Diameter: 13/16 Right Ear Diameter: 13/16 Top Bore Diameter: 6.5/8 Bottom Bore Diameter: 8.5/8 SWL: 5 Tons Manufacturer: VAR BJ
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202059 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

7 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3493

Left Ear Diameter: 3/4 Right Ear Diameter: 3/4 Top Bore Diameter: 7 Bottom Bore Diameter: 7 Door Gap: 1/16 Hinge Gap: 1/4" SWL: 5 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202060 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

7 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3487

Left Ear Diameter: 11/16 Right Ear Diameter: 11/16 Top Bore Diameter: 7 Bottom Bore Diameter: 7 Door Gap: 1/8 Hinge Gap: 7/16" SWL: 5 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202061 Identification Number Date of Examination 24/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 OD SINGLE JOINT ELEVATOR

DIMENSIONS

3178

Left Ear Diameter: 11/16 Right Ear Diameter: 11/16 Top Bore Diameter: 5.1/2 Bottom Bore Diameter: 5.1/2 Door Gap: 9/16 Hinge Gap: 7/16" SWL: 2 Tons
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: RIG FLOOR
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 24/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202062 Identification Number Date of Examination 07/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 IEU DRILL PIPE ELEVATOR

DIMENSIONS

NL 46430

Left Ear Diameter: 4.3/4 Right Ear Diameter: 6 Top Bore Diameter: 7.13/16 Middle Bore Diameter: 5.3/4 Bottom Bore Diameter: 5.15/16 SWL: 350 Tons Manufacturer: VARCO BJ TYPE-(GG) AIR OPERATED ELEVATOR
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: CANTILEVER DECK
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 07/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 202063 Identification Number Date of Examination 09/01/2014 Examiner OGEH EMEDOH Qualifications FMLP, LEEA, NDT LEVEL II MT, PT & UT

Description of Equipment:

5.1/2 IEU DRILL PIPE ELEVATOR

DIMENSIONS

NL 0147092

Left Ear Diameter: 4.3/4 Right Ear Diameter: 4.3/4 Top Bore Diameter: 7.7/8 Middle Bore Diameter: 5.7/8 Bottom Bore Diameter: 5.7/8 Hinge Gap Diameter: 1/4 Door Gap Diameter: 5/16 SWL: 350 Tons Manufacturer: VARCO BJ TYPE-(GG) AIR OPERATED ELEVATOR
METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found.


LOCATION: CANTILEVER DECK
SPECIFICATION : API RP 8B, ASTM E 1444 MPI : WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIZING METHOD: CONTINUOUS MAGNETIC FIELD INDICATOR: BURMAH CASTROL

Name and address of equipment owner:

Address of premises where Test / Examination was held:

Transocean Support Services

MAGELLAN

We hereby certify that on 09/01/2014 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector: Name of Inspector: OGEH EMEDOH

Revision No: R01

Effective Date: 29th August 2013

Doc No: JCI-C-VMPI-01

You might also like