Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description

6
6.1

Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description
Flexi Power Module (FPMA) and sub-modules (FPAA and FPBA) operation
Flexi Power Module (FPMA) is an optional module. It comprises FPMA mechanics and AC and DC interfaces. The actual power sub-modules are the following:
.

Flexi Power AC/DC sub-module 200-240 V AC (FPAA) Flexi Power Battery sub-module (FPBA)

The maximum number of sub-modules in an FPMA is four. For installation instructions, see section Installing Flexi Power Module (FPMA) in the Installing Flexi EDGE BTS Optional Items document. The FPMA is presented in the following figures.

DN70178394 Issue 3-0 en 19/06/2008

# Nokia Siemens Networks

29 (128)

Optional Items Description

Type label

DN70230045

Figure 9.

Power Module (FPMA)

DN7084386

Figure 10.

FPMA: full configuration with two FPAAs and two FPBAs

30 (128)

# Nokia Siemens Networks

DN70178394 Issue 3-0 en 19/06/2008

Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description

For examples of how many FPMAs are required for common configurations, see section Common stack, wall and pole configurations in Creating Stack, Wall and Pole Configurations, Common cabinet configurations in Creating FCIA Configurations or Creating FCOA Configurations or Common sector configurations in Creating Stack, Wall and Pole Configurations, Creating FCIA Configurations or Creating FCOA Configurations.

6.1.1

Operation
The FPMA can support 1-phase and 3-phase AC input. The nominal input voltage is 200-240 V AC (the operating voltage range is 180 - 276 V AC). The maximum output power from the FPMA is 4kW (with 4 FPAAs). Flexi Power AC-DC sub-module (FPAA) The main function of the FPAA is to provide the BTS with nominal 48 V DC power from an AC supply. Maximum DC output power of one FPAA module is 1000 W. A nominal 48 V DC supply is intended for BTS internal use only (a nominal 48 V DC supply is not intended for 3rd party equipment because they may require lower conducted emission level than EN55022 Class A). It should be especially noted that an external lead acid battery for longer backup times cannot be connected to nominal 48 V DC supply. (This is because the temperature compensation of charging voltage is not supported). The FPAA includes its own integrated selfcontrolled fan. In case the fan fails, an alarm is generated and the FPAA has to be replaced (the fan alone cannot be replaced). The FPAA unit remembers the main control switch position. If the FPAA power is switched to Standby, the power remains OFF after input voltage interrupt. The stand-by switch is used for switching the FPAA unit ON/Stand-by when AC input voltage has been connected to the FPAA unit. Flexi Power Battery sub-module (FPBA) The Flexi Power Battery Sub-Module (FPBA) is a separate optional submodule used together with the FPAA. The FPBA provides short-term battery backup time when the AC power mains is down on a Flexi BTS site. The FPBA is a lithium ion battery. The maximum DC output power from one FPBA module is 1000 W. The input power for the BTS cannot exceed the maximum output power of the installed batteries. Otherwise the batteries do not provide the BTS with the needed power during power failure.

DN70178394 Issue 3-0 en 19/06/2008

# Nokia Siemens Networks

31 (128)

Optional Items Description

The power switch of the FPBA unit controls input power. Batteries can be drained by the BTS if the power switch is set to OFF position. The stand-by switch is used for switching the FPBA unit ON/Stand-by when AC input voltage has been connected to the FPBA unit. Lightning protection requirements
.

+/- 2 kV, 1.2/50 s pulse, Rs=(2 + 10 ) (line to ground, common) +/- 1 kV, 1.2/50 s pulse, Rs=2 (line to line, differential) +/- 6 kV, 1.2/50 s pulse, Rs=2 (each phase conductor to greenwire ground or neutral conductor, neutral conductor and green-wire ground)

6.2

Flexi Power Module (FPMA) and sub-module (FPAA and FPBA) interfaces
FPMA front panel connectors The connectors on the FPMA front panel, their types and purposes are listed in the table below.

Table 11. Connector


Power supply in Power supply out Grounding

FPMA front panel connectors, types and purposes Purpose


AC main power supply in DC feed to the BTS Module grounding

Type
Terminal block 2-wire DC cable 4 x multibeam 2 x M5

FPAA front panel connectors There is a stand-by switch on the front panel of the FPAA. The stand-by switch is used for switching the FPAA unit ON/stand-by. The connectors on the FPAA front panel, their types and purposes are listed in the table below.

32 (128)

# Nokia Siemens Networks

DN70178394 Issue 3-0 en 19/06/2008

Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description

Table 12. Connector


AC cable connector DC connector Alarm connector Operational state visual indication

FPAA front panel connectors, types and purposes Purpose


AC input DC output Alarms** FPAA state or alarm indication

Type
Mate-N-Lock Multi-beam power supply connector 2 x RJ-45* tri-colour LED

*for chaining **Alarm 1 (AL01): AC input failure (alarm is sent when AC input voltage is missing or it is out of range). **Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, cooling fan failure, output power is low or over temperature shut down is ON). FPBA front panel connectors There is a stand-by switch on the front panel of the FPBA. The connectors on the FPBA front panel, their types and purposes are listed in the table below.

Table 13. Connector


DC input/output connector Alarm connector Operational state visual indication

FPBA front panel connectors, types and purposes Purpose


DC input and output Alarms** FPBA state or alarm indication

Type
Multi-beam power supply connector 2 x RJ-45* tri-colour LED

*for chaining

DN70178394 Issue 3-0 en 19/06/2008

# Nokia Siemens Networks

33 (128)

Optional Items Description

**Alarm 2 (AL02): maintenance needed (possible reasons are unit failure, output power is low or unit has reached end of it's life). **Unit has an input for Alarm 1 (AL01) from FPAA unit (Alarm 1 is a trigger for battery discharging).

6.3

Flexi Power Module (FPMA) dimensions and weight


The following table lists the dimensions and weight for the Power Module.

Table 14. Property


Height

Dimensions and weight of the Power Module FPMA


133 mm/3 U (5.2 in.)

Width

447 mm (17.6 in.)

Depth without covers

422 mm (16.6 in.)

Depth with covers

560 mm (22.1 in.)

Weight (empty)

< 11 kg (< 24.3 lbs)

Weight (fully equipped with one AC/DC power module and batteries)

28 kg (61.9 lbs)

6.4

Flexi power sub-module (FPAA and FPBA) LED indications


FPAA LED indications The FPAA LED indications are explained in the table below. Read the information on LED indications thoroughly. A blinking red LED does not always require removing the module.

34 (128)

# Nokia Siemens Networks

DN70178394 Issue 3-0 en 19/06/2008

Flexi Power Module (FPMA) and submodules (FPAA and FPBA) description

Table 15. Colour


Yellow Green Red Red, blinking

FPAA LED indications Explanation


Stand-by (AC connected) Normal operation Alarm or fault Unit operating with abnormal input voltage

See the following figure for the location of the FPAA LED.

LED

DN70350654

Figure 11.

FPAA LED

FPBA LED indications The FPBA LED indications are explained in the table below.

Table 16. Colour


Yellow Ggreen

FPBA LED indications Explanation


Stand-by (DC connected from FPAA) Normal operation, battery OK Charging Discharging Forced discharge mode Minor alarm Major alarm or fault

Green, blinking slowly Green, blinking fast Blinking fast between green and yellow Red, blinking fast Red

DN70178394 Issue 3-0 en 19/06/2008

# Nokia Siemens Networks

35 (128)

Optional Items Description

The LED's slow blinking frequency is 1 Hz (1 sec) and fast blinking frequency 2 Hz (0.5 sec). See the following figure for the location of the FPBA LED.

LED

DN70350678

Figure 12.

FPBA LED

36 (128)

# Nokia Siemens Networks

DN70178394 Issue 3-0 en 19/06/2008