Distribution for:
Europe ( NL, DK, N, S, F) NOX SYSTEMS AG Phone +423 370 25 25 Alvierweg 17 Fax +423 370 25 26 FL-9490 Vaduz info@noxsystems.com Liechtenstein www.noxsystems.com Scandinavia (DK, N, S, F) SHJ Elektronik Phone +45 30 25 87 14 Herningvej 258 Fax +45 98 15 87 41 DK-9220 Aalborg st svend@shjelektronik.dk Denmark www.shjelektronik.dk Netherlands (NL) ARAS Security B.V. Thomas Edisonweg 5 NL-5151 DH Drunen Netherlands

Phone +31 416 32 00 42 Fax +31 416 37 95 00 sales@aras.nl www.aras.nl

FFIS approved class 3 DANAK/DBI Security grade 3 Registred in Denmark, Sweden, Norway Netherlands Category 3 Austria VS (P)

EN 50130-4 EN 50131-6

NOX SYSTEMS AG Alvierweg 17 FL-9490 Vaduz Liechtenstein

P: +423 370 25 25 F: +423 370 25 26 www.noxsystems.com

Page 2 / 64

Components Overview July 2011

Index
NOX Control Units _____________________________________________________________ 5 NOX SYS, NOX Control Unit ...................................................................................................... 5 NOX Lite Sets, Small Control Units ............................................................................................. 6 Control Units Spare Parts and Single Components__________________________________ 8 Components for NOX SYS and NOX Lite ................................................................................... 8 NOX PS5, Power Supply Unit 5A .............................................................................................. 11 NOX PS5, Power Supply Unit 5A with Adapter Plate as Replacement for NOX PSU ................ 12 NOX PS2, Power Supply Unit 2A .............................................................................................. 13 NOX BOX, Control Unit Housing for NOX CPU / NOX PS5 ...................................................... 14 NOX PS5, Power Supply Unit 5A integrated in NOX BOX Housing .......................................... 14 NOX PS2, Power Supply Unit 2A integrated in NOX BOX Lite Housing .................................... 15 NOX Control Panels __________________________________________________________ 16 NOX CPA AP , Control Panel on wall........................................................................................ 16 NOX CPA UP ..., Control Panels in wall .................................................................................... 17 NOX TPA Rev.C, Touch Panel 10.4 ........................................................................................ 18 NOX PC User Interfaces Software ............................................................................................ 19 Code Keypads .......................................................................................................................... 20 NOX KPD , Code Keypads ............................................................................................... 20 NOX UPE, Code Keypad in Feller Edizio Due Design .......................................................... 21 NOX UPK, Key Switch in Feller Edizio Due Design................................................................... 22 NOX Bus, I/O Modules for Sensors / Actuators ____________________________________ 23 NOX IO1, Single In-/Output Module .......................................................................................... 23 NOX IO4 Rev.C, Quadruple In-/Output Module ......................................................................... 24 NOX RE4, Quadruple Relay Module ......................................................................................... 25 NOX O32, 32 Open Collector Output Module ............................................................................ 26 NOX M31, Mini In-/Output Module ............................................................................................ 27 NOX MIO Rev.B, Multi Input/Output Module ............................................................................. 28 NOX UP4, In- / Outputmodule in Feller Edizio Due Design ....................................................... 29 NOX IR1, NOX Bus I/O Module for Alarmcom IR270T Detector ................................................ 30 NOX Bus Cardreader Interfaces _________________________________________________ 31 NOX CRx, Cardreader Interface Modules ................................................................................. 31 NOX CMx, Cardreader Interface Module with Offline Functions ................................................ 32 NOX Bus Repeater / Converter and Communication Modules ________________________ 33 NOX RPT, NOX Bus Repeater / Converter ............................................................................... 33 NOX ATU, Serial Communication Interface with ATU Protocol ................................................. 34 NOX ESP, Serial Interface with several Protocols ..................................................................... 35 NOX Bus Extension via TCP/IP ................................................................................................ 36 NOX MXA, Bus Extension via TCP/IP .................................................................................. 36 NOX MXA mini, Mini Bus Extension via TCP/IP ................................................................... 37 Interface Module for Third Party Systems ________________________________________ 38 NOX IS9, Interface for SAEL S9 (SECULON) ........................................................................... 38 NOX S8P RevC, Interface for SAEL S8 (PRISMA) ................................................................... 39 NOX IFT, Interface to Thor Bus................................................................................................. 40 NOX ABI M-Bus, Interface to ABI Control Unit with M-Bus ........................................................ 41 NOX RXP, Wireless Receiver for Paradox Detectors ................................................................ 42 NOX Sensors ________________________________________________________________ 43 NOX THS, Temperature and Humidity Sensor .......................................................................... 43 NOX THT, Wireless Temperature and Humidity Sensor............................................................ 44 NOX FLD, Water Detector ........................................................................................................ 45

Components Overview July 2011

Page 3 / 64

Wireless Components of NOX Picture Monitoring System (PMGS) ____________________ 46 Wireless receiver modules ........................................................................................................46 NOX RXM, Wireless Receiver Module with NOX Bus ...........................................................46 NOX RXR, Wireless Receiver Module with Relay .................................................................47 NOX BPR, portable alerting receiver ....................................................................................48 Wireless transmitter modules ....................................................................................................49 NOX TXM, wireless picture detector .....................................................................................49 NOX TXS, Wireless Picture Detector Mini ............................................................................50 NOX TXK, Wireless Detector ................................................................................................51 NOX TXT, Wireless Transmission Detector Mini ..................................................................51 NOX TXM REF, Radio Reference Transmitter......................................................................52 NOX THT, Wireless Temperature and Humidity Sensor .......................................................53 Supplies / Accessories_________________________________________________________ 54 Mounting Plate ..........................................................................................................................54 Empty Plate for 8 DASK Cases ............................................................................................54 Mounting Plate with 8 DASK Cases and Cables ...................................................................54 Mounting Plate with 8 DASK Cases ......................................................................................55 Empty Plate for 4 DASK Cases ............................................................................................55 Mounting Plate with 4 DASK Cases and Cables ...................................................................56 NOX TNA, Empty Mounting Plate .........................................................................................56 DASK Case ...............................................................................................................................57 PCBA Fixation for DASK Case..................................................................................................57 Batteries....................................................................................................................................58 Cables ......................................................................................................................................58 Cable NOX Bus, 4th Dask Plate ...........................................................................................58 Cable NOX Bus, 8th Dask Plate ...........................................................................................59 NOX Bus Terminal................................................................................................................59 USB Cable to CPU_V3 Motherboard ....................................................................................60 Spare Fuses for NOX Modules .................................................................................................61 SMD Fuse Set 500mAT ........................................................................................................61 SMD Fuse Set 1AT...............................................................................................................61 SMD Fuse Set 2AT...............................................................................................................61 SMD Fuse Set 3AT...............................................................................................................61 SMD Fuse Set 5AT...............................................................................................................61 NOX Software Components _____________________________________________________ 62 NOX Config, PC Configuration Software for the NOX Security System .....................................62 NOX PC Control Panel..............................................................................................................62 NOX PC TPA Licence, PC Touch Panel Software Licence .......................................................63 NOX SIMS, Security Information Managment System...............................................................63 NOX Logger ..............................................................................................................................63 NOX Time .................................................................................................................................63 NOX iNOX ................................................................................................................................64 NOX iOS ...................................................................................................................................64

Page 4 / 64

Components Overview July 2011

NOX Control Units


NOX SYS, NOX Control Unit

Specification
Bottom Housing Cover Dimensions (L x W x H) Weight with Cover (without batteries) Peak current from NOX PS5 Connections Tamper Monitoring Vibration Protection Space for alarm transmission system Space for Batteries Steel sheet galvanised, 2mm Steel sheet, 2mm, powder coated RAL9006 (white aluminium) 605 x 410 x 124 mm 15.9 kg 5A AC Input, Batteries, 3 x NOX Bus, 2 x 15VDC Output Integrated, through tamper contact Integrated, vibration sensor on NOX MIO up to 150 x 200 x 95 mm up to 2 x 17 Ah, Valve Regulated Lead Acid batteries (VRLA type) N106, NOX BOX, Control Unit Housing N109, NOX PS5, Power Supply Unit 5A N166, NOX CPU V3, Central Processing Unit complete (with SW Licence NOX Full) N105, NOX MIO, Multi Input/Output Module (internal) N101

Scope of delivery Part. No.

The Unit is delivered assembled and tested. The latest system software is installed.

Components Overview July 2011

Page 5 / 64

NOX Lite Sets, Small Control Units

Specification (NOX Lite Set with MIO)


Bottom Housing Cover Dimensions Unit (L x W x H) Weight with Cover (without batteries, without Control Panel) Peak current from NOX PS2 Connections Tamper Monitoring Vibration Protection Space for alarm transmission system Space for Batteries Control Panel Steel sheet galvanised, 2mm Steel sheet, 2mm, powder coated RAL9006 (white aluminium) 405 x 315 x 110 mm 7.0 kg 2A AC Input, Batteries, 3 x NOX Bus, 2 x 15VDC Output Integrated, through tamper contact Integrated, vibration sensor on NOX MIO up to 160 x 120 x 85 mm up to 2 x 7 Ah, Valve Regulated Lead Acid Batteries (VRLA type) Including NOX CPA AP PVC (N146) N173, NOX BOX Lite, Control Unit Housing Lite N188, NOX PS2, Power Supply Unit 2A N175, NOX CPU V3 Lite, Central Processing Unit Lite complete (with SW Licence NOX Lite) N105, NOX MIO, Multi Input/Output Module (internal) N146, NOX CPA AP PVC, Control Panel with LCD, on-wall mount N171

Scope of delivery

Part. No.

Specification (NOX Lite Set without MIO)


Weight with Cover (without batteries, without Control Panel) Vibration Protection 6.9 kg none N173, NOX BOX Lite, Control Unit Housing Lite N188, NOX PS2, Power Supply Unit 2A N175, NOX CPU V3 Lite, Central Processing Unit Lite complete (with SW Licence NOX Lite) N146, NOX CPA AP PVC, Control Panel with LCD, on-wall mount N177

Scope of delivery

Part. No.

All other specifications are identical with part no. N171. The Unit is delivered assembled and tested. The latest system software is installed.

Page 6 / 64

Components Overview July 2011

Licences from the NOX System software


Description Licence NOX Lite Update NOX Lite -> NOX Advanced Update NOX Lite -> NOX Full Update NOX Advanced -> NOX Full NOX Lite (Standard for NOX Lite Sets) 50 20 3 yes no no no only Slave no no yes Part. No. -- (included in N171 and N177) S101 S102 S103 (included in N101)

SW Licence key Max. number of users Max. number of Areas Max. number of Timeprofiles NOX TIO (without IP/Telnet communication) NOX TIO complete Alarm per email IP Bus (NPort) Master/Slave Modbus Interface Smart Phone, Smart Pad Interface (for iPhone/iPod/Android) SIMS Server integration

NOX Advanced 100 40 6 yes yes yes yes only Slave no yes yes

NOX Full unlimited (10000) unlimited (800) unlimited(400) yes yes Yes yes Master and Slave yes yes yes

Components Overview July 2011

Page 7 / 64

Control Units Spare Parts and Single Components


Components for NOX SYS and NOX Lite
Component Part No. Description

N168

NOX CPU V3, Motherboard (without Toradex CPU Module (DIMM))

Common for NOX SYS and NOX Lite

T528

Tamper contact with cable and plug

T525

Cable NOX Bus, to connect any modules (e.g. MIO)

T530

Cable USB to CPU_V3 Motherboard

Page 8 / 64

Components Overview July 2011

N106

NOX BOX, Control Unit Housing includes: Covers for the cable entries Holding bracket for 2x 17Ah batteries (without batteries) T528, Tamper contact with cable and connector NOX CPU V3, CPU complete (with SW Licence NOX Full) consists of: N168, NOX CPU V3, Motherboard with 3 bus connections N167, Toradex CPU Module (DIMM) with SW Licence NOX Full Replacement for NOX CPU V1 and NOX CPU V2

N166 For NOX SYS only

N167

Toradex CPU Module (DIMM) includes: Windows Embedded NOX System Software with SW Licence NOX Full

T529

Cable, PS5 to the batteries

Components Overview July 2011

Page 9 / 64

N173

NOX BOX Lite, Control Unit Housing Lite includes: T528, Tamper contact with cable and plug Replacement for SE06, NOX SE emty cabinet.

N175 NOX Lite

NOX CPU V3 Lite, complete CPU (with SW Licence NOX Lite) contents: N168, NOX CPU V3, Motherboard with 3 bus connections N174, Toradex CPU Module (DIMM) with SW Licence NOX Lite

N174

Toradex CPU Module (DIMM) includes: Windows Embedded NOX System Software with SW Licence NOX Lite

T524

Cable, PS2 to the batteries

Page 10 / 64

Components Overview July 2011

NOX PS5, Power Supply Unit 5A

Specification
Dimensions (L x W x H) Weight Input Voltage Output Voltage Maximum Output Current Batteries Charge Voltage Batteries Charge Current Batteries Supported Connections Part. No. 220 x 125 x 100 mm 1.0 kg 100 240 VAC; 50/60Hz (with active PFC) 15VDC 5A 26 30VDC (adjustable) max. 2A 2 x 7 Ah/12V to 2 x 42 Ah/12V AC Input, Batteries, Tamper contact, NOX Bus, 2 x 15VDC Output N109

The Unit is delivered assembled and tested.


Single component Part. No. Description

N138

NOX PS5 Print 5A (PCBA)

N139

AD/DC Power Supply 32V/150W (with active PFC, overload and overtemperature protection)

T522

Cable, PS5 Power Supply to Print (PCBA)

Components Overview July 2011

Page 11 / 64

NOX PS5, Power Supply Unit 5A with Adapter Plate as Replacement for NOX PSU

When replacing the NOX PSU power supply unit, the NOX PS5 with the adapter plate fits into the older housing. Specification
Adapter Plate Material Dimensions (L x W x H) Weight Part. No. Aluminium 340 x 125 x 95 mm 1.2kg N140

All other specifications are identical with part no. N109. The Unit is delivered assembled and tested.

Page 12 / 64

Components Overview July 2011

NOX PS2, Power Supply Unit 2A


Small low priced power supply unit with 2A continous output current.

Specification
Dimensions (L x W x H) Weight Input Voltage Output Voltage Maximum Output Current Battery Charge Voltage Batteriy Charge Current Batteries Supported Part. No. 180 x 125 x 80 mm 0.64kg 100 240 VAC; 50/60Hz 15 VDC 2 A continuous 4 A peak (without Batteries charging during this time) 26 30VDC (adjustable) max. 2A 2 x 7 Ah/12V bis 2 x 42 Ah/12V N188

The Unit is delivered with cable, without mounting parts.


Component Part. No. Description

N138

NOX PS5 Print (PCBA)

N176

AD/DC Power Supply 32V/75W (with overload and overtemperature protection)

T523

Cable PS2, Power Supply to Print

Components Overview July 2011

Page 13 / 64

NOX BOX, Control Unit Housing for NOX CPU / NOX PS5

Specification Bottom Housing Cover Dimensions (L x W x H) Weight with Cover (without batteries) Scope of delivery Part. No.

Steel sheet galvanised, 2mm Steel sheet, 2mm, powder coated RAL9006 (white aluminium) 604 x 404 x 124 mm 12.8 kg - Covers for the cable entries (2 pcs.) - Holding bracket for 2 x 17Ah batteries (without batteries) - T528, Tamper contact with cable and plug N106

NOX PS5, Power Supply Unit 5A integrated in NOX BOX Housing

Specification
Part. No. N104

All other specifications are identical with part no. N109 and N106. The unit is delivered assembled and tested with the housing.

Page 14 / 64

Components Overview July 2011

NOX PS2, Power Supply Unit 2A integrated in NOX BOX Lite Housing

Specification
Bottom Housing Cover Dimensions (L x W x H) Weight with Cover (without batteries) Part. No. Steel sheet, galvanised, 2mm Steel sheet, 2mm, powder coated RAL9006 (white aluminium) 510 x 320 x 105 mm 6.70 kg N189

All other specifications are identical with part no. N188. The Unit is delivered assembled and tested with the Lite housing.

Components Overview July 2011

Page 15 / 64

NOX Control Panels


With a control panel the NOX Security System can be controlled and monitored.

NOX CPA AP , Control Panel on wall


These control panels have a full graphic display with 128 x 64 Pixel with white backlight and a numeric pad with additional function keys.

N110AP Specification (NOX CPA AP Aluminium)


Case Display Backlight Lexan Screen Tamper Monitoring Buzzer Connection to the Control Unit Dimensions (L x W x H) Mounting Part. No.

N146

Aluminium anodized Full graphic LCD 128 x 64 pixels LED white Light grey with numeric pad and function keys Integrated (through tamper contact) Integrated NOX Bus 175 x 110 x 23mm On wall N110AP

Specification (NOX CPA AP PVC)


Case Dimensions (L x W x H) Part. No. PVC grey 177 x 112 x 29mm N146

All other specifications are identical with part no. N110AP.

Page 16 / 64

Components Overview July 2011

NOX CPA UP ..., Control Panels in wall


These control panel cosists of a graphical display (128 x 64 Pixel) with white backlight and a numeric pad with function keys.

N110UP Specification (NOX CPA UP Aluminium)


Case Display Backlight Foilkeypad Monitoring tamper Buzzer Connection to the Control Unit Dimensions (L x W x H) Mount Part. No.

N114
Aluminium anodized Full graphic LCD 128 x 64 Pixel LED white Light-grey with numeric pad and function keys Integrated (through tamper contact) Integrated NOX Bus 212 x 148 x 23mm In wall N110UP

Specification (NOX CPA UP Design)


Case Dimensions (L x W x H) Mount Part. No. Aluminium anodized, without visible screws 212 x 148 x 23mm In wall; Steel base plate with holding magnet N114

All other specifications are identical with part no. N110UP.

NOX CPA UP Mounting Supplies


Supply Part. No. Description

N110Box

Wooden box for NOX CPA UP for in wall mount

Components Overview July 2011

Page 17 / 64

NOX TPA Rev.C, Touch Panel 10.4


Additonally to the controlling and monitoring capabilities of the whole system, the 10.4 Touch Panel Rev.C offers as a highlight, the ability to arm and disarm areas directly on coloured floor plans.

Specification (NOX TPA Rev.C)


Front Dimensions (L x W x H) Input Voltage Connection to the Control Unit Steel, powder coated RAL9002 (grey white) 312 x 242 x 76 mm 100 -240 VAC (external AC Adapter) Ethernet (RJ45) -Touch Panel PC with: 10.4 SVGA TFT LCD Microsoft Windows XP Embedded with SP3 Microsoft .NET 2.0 Framework 128MB RAM, 128MB Flash Memory -TPALoader2 Software (loads NOXTPA2 application from the control unit) -External AC Adapter -Front frame -without mounting supplies (see below) N111

Scope of delivery

Part. No.

The mounting supply decides the type of mounting, in wall or on wall (with noble natural beech frame).

NOX TPA mounting accessories (for any TPA Rev)


Supply
Part. No. Description

N111Box

Wooden box for NOX TPA for in wall mount

N112

In wall mount frame aluminium nature Dimensions (L x W x H): 392 x 312 x 4 mm

Page 18 / 64

Components Overview July 2011

Supply

Part. No.

Description

N118

On wall mount natural beech frame, clearcoat finish Outside dimensions (L x W x H): 420 x 345 x 80 mm

N113

Complete on wall mount frame, consists of: - N112, In wall frame aluminium nature - N118, On wall frame in natural beech, clearcoat finish

NOX PC User Interfaces Software


Specification (NOX PC TPA Software licence)
Basic Functions Licence Operating systems Part. No. Identically with NOXTPA2 software (with floorplans), optimized for Touchcontrol; has to be configured as a module Final constumer licence for 1 Control Unit (can be installed on any number of PCs) Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit) S100 This licence runs with: PCTPALoader.exe (Application TPA V1.00 to V1.99e which runs on TPA Rev.A and TPA Rev.B Hardware as well), not for new installations! PCTPA2Loader.exe (Application TPA V2.00 to actual Version which runs on TPA Rev.C Hardware as well)

Compatibility

More informations at NOX Software Components. Specification (NOX PC User Panel Software)
Basic Functions Licence Operating system Part. No. Allows complete control on user level with: - User Profiles - Time Profiles - Filter rules for Log entries - Runs without configuration none Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit) S401

More informations at NOX Software Components.

Components Overview July 2011

Page 19 / 64

Code Keypads
NOX KPD , Code Keypads
The Code keypads consist of a numeric pad and two different coloured LEDs as status indicators. The Units are normally used to arm or disarm areas or to release a door opener.

N113AP
Case Foil Keypad Display Tamper Monitoring Buzzer Connection to the control unit Dimensions (L x W x H) Mount Part. No.

N113UP

N116

Specification (NOX KPD AP Aluminium)


Aluminium anodized Light-grey with numeric pad and function keys LED red and green (as status indicator) Integrated, through tamper contact Integrated NOX Bus 100 x 70 x 23mm On wall N113AP

Specification (NOX KPD UP Aluminium)


Dimensions (L x W x H) Mount Part. No. 136 x 106 x 23mm In wall N113UP

All other specifications are identical with part no. N113AP. Specification (NOX KPD UP Design)
Case Dimensions (L x W x H) Mount Part. No. Aluminium anodized, no visible screws 136 x 106 x 23mm In wall; Steel base plate with holding magnet N116

All other specifications are identical with part no. N113UP.

Page 20 / 64

Components Overview July 2011

NOX KPD UP Montagezubehr


Supply Part. No. Description

N113Box

Wooden Box for NOX KPD UP, in wall mount

NOX UPE, Code Keypad in Feller Edizio Due Design


The code keypad consists of a numeric pad and two different coloured LEDs as status indicators. The Unit is normally used to arm and disarm areas or to release a door opener. The code keypad can be mounted with a conventional socket and combine with different covers as required from the Feller Edizio Due Design.

N250 Specification
Case Lexan Screen Display Tamper Monitoring Buzzer Connection to the control unit Dimensions (L x W x H) -incl. Feller Frame -only PCBA Mount Part. No. Feller Edizio Due Designframe, white Light-grey with numeric pad and function keys LED red and green (as status indicator) Integrated, through tamper contact Integrated NOX Bus 88 x 88 x 35 mm 60 x 60 x 35 mm In wall N250

Edizio Due Design line was specially designed for the Swiss Market and according to Swiss Standards.

Components Overview July 2011

Page 21 / 64

NOX UPK, Key Switch in Feller Edizio Due Design


Universal key switch with cylinder lock and 2 different coloured LEDs as state indicator. The key switch is available in 2 versions, with or without state LEDs.

Variante C218 Specification (NOX UPK-xx)


Case Dimensions (L x W x H) (incl. Feller Frame) Typ of cylinder Tamper Monitoring Connections Feller Edizio Due Designframe, white 88 x 88 x 35 mm Kaba 8 with 2 keys (www.kaba.ch/en) Integrated, through tamper contact Potential free contacts and driving LEDs (C218 only) with 15VDC (optional 5VDC)

Versions of NOX UPK, Key-switch


Label NOX UPK-Z NOX UPK-ZL Description Key-switch, Key-switch, without LEDs, with LEDs, with Cylinder Kaba 8 with Cylinder Kaba 8 Part No. C216 C218

Page 22 / 64

Components Overview July 2011

NOX Bus, I/O Modules for Sensors / Actuators


NOX IO1, Single In-/Output Module
The NOX IO1 module has one resistance controlled input and one free programmable relay. The module can be used for e.g. monitoring a door and for triggering the door opener at the same time.

Specification (NOX IO1)


Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus 1 resistance monitored Input 1 potential-free Relay output (max. contact rating 30V/1A) N117

Components Overview July 2011

Page 23 / 64

NOX IO4 Rev.C, Quadruple In-/Output Module


The IO4 Rev.C Module has four resistance monitored inputs. As a unique feature the monitored resistor value can be configured for each input individually in the range from 3 k up to 40 k. Thus different types of detectors can be connected or migrated from existing installation quite simple. In addition individually input delay time is also possible. The module supports Tripple end of line resistors. This allows covering alarm, tampering monitoring and anti mask detection on one inputting only. Additional the module has 4 open collector outputs.

Specification
Case Tamper Monitoring Dimensions (L x W x H) Connection to the Control Unit Inputs Outputs Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27 mm NOX Bus 4 resistance monitored Inputs 4 Open Collector Outputs (max. output current 500mA for all 4 Outputs) N119

Replacement for NOX IN4, Inputmodule (Part. No. N120)

Page 24 / 64

Components Overview July 2011

NOX RE4, Quadruple Relay Module


NOX RE4 is a universal output module with four free programmable relays.

Specification
Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Inputs Outputs Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27 mm NOX Bus None 4 potential free Relay Outputs, each 30VDC@1A N122

Components Overview July 2011

Page 25 / 64

NOX O32, 32 Open Collector Output Module


This module suits well for applications which require many outputs at once. The outputs can be connected either via screw terminal or through 0.1 male header multipoint connector. The ports are configurable by a jumper as Open Collector, with 2VDC or with VBus (15VDC) potentia. The power supply for LEDs is variable in the range of 1.9 - 2.2. Volt. Every output can be programmed with the graphic NOX Formel Editor and can toggle with a free programmable frequency. All of these features are combined in a compact PCBA form factor.

Specification
Case Tamper Monitoring Dimensions (L x W x H) print (PCBA) Connection to the control unit Input Outputs Internal voltage supply for LED Part. No. None (fits in MIO Case) Integrated, through tamper contact (only activ with MIO PVC Case) 118 x 55 x 15 mm NOX Bus 1 digital Input without resistance monitoring (open / closed, e.g. external contact) 32 Open Collector Outputs (max. output current 300mA for each Output, max. 3A total) Configurable as: Open Collector, with 2VDC or VBus (15VDC) potential 1.9-2.2 VDC (max.1A) to drive LEDs on the ports directly N155

Page 26 / 64

Components Overview July 2011

NOX M31, Mini In-/Output Module


The NOX M31 is a small, compact module with one open collector output and three inputs, its designed to fit directly into the case of a detector. The module has 3 non resistance monitored inputs (e.g. for external contacts).

Specification
Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Inputs Outputs Part. No. none Connection available 28 x 20 x 10 mm NOX Bus 3 none resistance monitored Inputs (open / closed) 1 Open Collector Output (max.output current 50mA) N121

Components Overview July 2011

Page 27 / 64

NOX MIO Rev.B, Multi Input/Output Module


The MIO Rev.B module can be used e.g. to connect an alarm transmission unit and to drive sirens and flash bulbs. As external version it can be used in a similar way but decentralized.

N105 (NOX MIO Rev.B internal) Specification (NOX MIO Rev.B external)
Case Tampe Monitoring Dimensions (L x W x H) Connection to the control unit Inputs Outputs Part. No.

N105e (NOX MIO Rev.B external)

Plastic, white Integrated, through tamper contact 150 x 100 x 36 mm NOX Bus 4 resistance monitored Inputs 8 potential-free Relay Outputs (max. contact rating 30V/1A) 4 Open Collector Outputs, individually fused (max. current for a single output 500mA) N105e

Specification (NOX MIO Rev.B internal)


Case Tamper Monitoring Dimensions (L x W x H) Part. No. None Through vibration sensor 120 x 67 x 12 mm N105

All other specifications are identical with part no. N105e.

Page 28 / 64

Components Overview July 2011

NOX UP4, In- / Outputmodule in Feller Edizio Due Design

The UP4 module offers four resistance monitored inputs to connect detectors and indicators to the NOX Bus. Unique is the separate adjustable resistor monitoring range from 3 k up to 40 k for each Input. This allows connecting different types of detectors and indicators and migrate existing installations. An individual time delay can be set for each input. The module supports Tripple end of line resistors. This allows covering alarm, tampering monitoring and anti mask detection on one inputting only. Additional the module has 2 open collector outputs integrated. Specification
Case Dimensions (L x W x H) (incl. Feller Frame) Tamper Monitoring Connection to the control unit Inputs Outputs Part. No. Feller Edizio Due Designframe with cover, white 88 x 88 x 35 mm Integrated, through tamper contact NOX Bus 4 resistance monitored Inputs 2 Open Collector Outputs (max. current for a single output 200mA) N251

Components Overview July 2011

Page 29 / 64

NOX IR1, NOX Bus I/O Module for Alarmcom IR270T Detector

Backside View Component Side View With this I/O module an Alarmcom IR270T detector can be connected to the NOX Bus. The module is mounted into the case of the detector. Specification
Case Dimensions (L x W x H) Tamper Monitoring Inputs Outputs Part. No. none 45 x 44 x 10 mm Functionality of the detector Alarm-, Tamper- and Antimask contacts NOX Bus; Detector arm/disarm, Detector Walktest N151

Page 30 / 64

Components Overview July 2011

NOX Bus Cardreader Interfaces


NOX CRx, Cardreader Interface Modules
Card readers from different manufacturers (e.g. Legic, Temic, Mifare, Hitag) with Wiegand or Data/Clock interfaces can be connected with the NOX CRx interface modules to the NOX Bus. In addition to the cardreader interface the NOX CRx modules have one resistance monitored input and one relay output.

Specification (NOX CRx) generally


Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus 1 resistance monitored Input 1 relay output (30V/1A)

Variants of the NOX CRx, Cardreader, Interface Modules


Description NOX CRD, with 26Bit Wiegand Interface NOX CRA, with Data/Clock Interface (Omron Protocol) NOX CRB, with 40Bit Wiegand Interface NOX CRC, with 27Bit and 40Bit Wiegand Interface for HID iCLASS reader NOX CRE, with Data/Clock Interface (Omron Protokoll) and keyboard support NOX CRF, with 26Bit Wiegand Interface and keyboard support NOX CRG, with Data/Clock Interface (Omron Protocol) for Acticon and ABI card readers NOX CRH, for HID RK40 NOX CRU, for Wiegand Interface up to 80Bit paket length (universal) compatible with CRC, CRD and CRH Part No. N115 N125 N126 N127 N128 N129 N130 N131 N132

Components Overview July 2011

Page 31 / 64

NOX CMx, Cardreader Interface Module with Offline Functions


The NOX CMx module offer additionally to the usual CRx functions an offline functionality if the connection to the control unit may gets interrupted. The NOX CMx can store 204 to 251 card codes directly.

Specification (NOX CMx) general


Case Tamper Monitoring Dimensions (L x W x H) Offline Functions Connection to the central unit Input Output Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm 204 to 251 batch cards are non volatile stored Formulas can be evaluated locally in the module (e.g. for door opener) NOX Bus 1 resistance monitored Input 1 Relay Output (30V/1A)

Variants of the NOX CMx, Cardreader Interface modules with offline functionality. (Non volatile memory for 251 fix programmed cards if not specified otherwise).
Description NOX CMD, with 26Bit Wiegand Interface NOX CME, with Data/Clock Interface (Omron Protocol) and keyboard support NOX CMF, with 26Bit Wiegand Interface and keyboard support NOX CMI, for UNITEK Cardreader with keyboard support NOX CML, for 50Bit Aras Cards NOX CMU, for Wiegand Interface 26..80Bit paket lenght (universal) Memory for total 204 cards: 24 complete programmed cards 180 cyclic cards (dynamic) Art. No. N215 N228 N229 N230 N231 N232

Page 32 / 64

Components Overview July 2011

NOX Bus Repeater / Converter and Communication Modules


NOX RPT, NOX Bus Repeater / Converter
The NOX RPT Module runs as a universal bus repeater (RS-485 up to RS-485) or alternatively as serial RS-232 interface (RS485 to RS-232). The function can be defined with the jumper on the module. The repeater allows an almost unlimited extension of the the bus cable length. The module decouples two bus lines, therefore bus communication problems are decreased. In addition the bus output is fused separately.

N141 Specification (NOX RPT, NOX Bus Repeater)


Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus NOX Bus NOX Bus N141

Specification (NOX RPT RS232, NOX Bus Converter)


Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus NOX Bus RS-232 with DB9 receptacle N141A

Components Overview July 2011

Page 33 / 64

NOX ATU, Serial Communication Interface with ATU Protocol


The NOX ATU module connects a NOX System with an alarm transmission device with ATU (Alarm Transmission Unit) protocol.

Specification
Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus NOX Bus RS-232 with ATU Protocol (Transmission from SIA Level 2 commands) N144

Page 34 / 64

Components Overview July 2011

NOX ESP, Serial Interface with several Protocols


The NOX ESP module supports the ESPA, IRIS and Musdo protocols and acts as a serial interface (RS-232) to various Alarm Transmission Systems.

Specification
Case Tamper Monitoring Dimensions (L x W x H) Connection to the control unit Input Output Part. No. Plastic ABS, white (DASK Case) Integrated, through tamper contact 85 x 66 x 27mm NOX Bus NOX Bus RS-232 with following protocols - ESPA 4.4.4 (Paging) -Chiron IRIS (SIA Level 2 / 3 Protocol), alarm transmission -Musdo, alarm transmission N147

Components Overview July 2011

Page 35 / 64

NOX Bus Extension via TCP/IP


NOX MXA, Bus Extension via TCP/IP
With NOX MXA a standard NOX Bus can be connected to a NOX Security System via TCP/IP. This Bus acts in the same manner as a direct connected NOX Bus.

N202 Specification (NOX MXA Components)


Connection to the control unit Output Scope of delivery Part. No. Through TCP/IP NOX Bus -MOXA Nport 5110, pre configured -modified NOX RPT Module N201

Specification (NOX MXA on mounting plate)


Installation plate Dimensions (L x W x H) Mounting DASK Case Scope of delivery Part. No. Aluminium 300 x 207 x 3 mm 4 x 4.5mm drills 5 pieces pre-assembled on mounting plate Pre-assembled, wired and tested on mounting plate -N201, NOX MXA components -5 x DASK Case, pre-installed -1 Cable channel N202

An additional Power supply (NOX PS5) for an auxiliary Bus is not integrated. With each NOX MXA up to 200 additional NOX Bus modules can be connected to the system.

Page 36 / 64

Components Overview July 2011

NOX MXA mini, Mini Bus Extension via TCP/IP


The NOX MXA mini has the same functionality as the NOX MXA but it has only 1 empty DASK case.

Specification
Baseplate Dimensions (L x W x H) Mounting DASK Case Scope of delivery Part. No. Aluminium 226 x 165 x 3 mm 4 x 4.5mm holes 5 pieces mounted on Baseplate Mounted, wired and tested on baseplate: -N201, NOX MXA Components -1 x DASK Case, wired -1 Cable channel N203

Components Overview July 2011

Page 37 / 64

Interface Module for Third Party Systems


NOX IS9, Interface for SAEL S9 (SECULON)
The NOX IS9 Interface allows to connect bus units from the SAEL S9 (Seculon) security system to the NOX Bus. All devices of the SAEL S9 system can be integrated into the NOX system (except control panel and power supply).

Specification
Baseplate Dimensions (L x W x H) Mounting Input Outputs Scope of delivery Part. No. Aluminium 155 x 120 x 30 mm direct into the NOX control unit housing NOX Bus 4 x SAEL S9 Bus connections with individual fusing (max. 99 S9 devices for one S9 Bus connection) NOX IS9 assembled on Baseplate N143

Page 38 / 64

Components Overview July 2011

NOX S8P RevC, Interface for SAEL S8 (PRISMA)

The NOX S8P RevC Interface module is used to connect bus devices from SAEL S8 (Prisma) system to the NOX Bus. Specification
Case Tamper Monitoring Dimensions (L x W x H) Input Output Part. No. Plastic, white Integrated, through tamper contact 150 x 100 x 36 mm NOX Bus 2 x SAEL S8 LAN Port N149

Components Overview July 2011

Page 39 / 64

NOX IFT, Interface to Thor Bus

The IFT Interface module converts the Thor Bus to the NOX Bus. It supports S-Art modules of Type 1xxx and 2xxx (Inputs and Outputs). Specification
Case Tamper Monitoring Dimensions (L x W x H) Print (PCB) Input Output Part. No. None (fits into MIO case) Integrated, through tamper contact (is only active with MIO PVC ) 118 x 55 x 15 mm NOX Bus 4 x Thor Bus connections N148

Page 40 / 64

Components Overview July 2011

NOX ABI M-Bus, Interface to ABI Control Unit with MBus


The NOX ABI interface allows to connect M-BUS devices of the ABI systemt (e.g. MC1500) to the NOX Bus. The Interface has two pieces; a NOX ABI and a NOX ISA module.

Specification
Case Tamper Monitoring Dimensions (L x W x H) per Case Input Output Scope of delivery Part. No. 2 x Plastic ABS, white (DASK case) Integrated (in both cases), trough tamper contact 85 x 66 x 27 mm NOX Bus (on NOX ABI) M-Bus (on NOX ISA) -NOX ABI, Interfacecard with NOX Bus -NOX ISA, Interfacecard with 1 x M-Bus port (for every M-Bus up to 120 ABI devices can be connected) N145

Supported ABI devices: 15191/15190 LAM 2 Inputs, 2 Outputs 15198 LAM-4 8 Inputs, 2 Outputs 15196 IOM 4 Inputs, 2 Relays 15193 RLM 2 Relays 15192 BLM Block lock module All inputs and output modules are programmable.

Components Overview July 2011

Page 41 / 64

NOX RXP, Wireless Receiver for Paradox Detectors


NOX RXP wireless receiver allows to integrate wireless motion detectors, door contacts, wireless portable transmitter, magnetic switches and remote controls of different systems from Paradox Security Systems, Canada.The receiver ist connected to the NOX bus. Multiple receivers can be used for larger installations. The transmitter can be used to arm and disarm areas or as panic alarm button.

Supported Paradox Devices: Wireless Motion Detector (e.g. PMD1P) Wireless Doorcontact (e.g. DCTXP2) Wireless Portable Transmitter (e.g. REM1, RAC1, REM15) Wireless Fire Warning Detector (e.g. SD738) Specification
Case Dimensions (L x W x H) Input Output Scope of delivery Part. No. PVC, white 172 x 155 x 28mm (without antenna) NOX Bus 4 x SAEL S9 Bus connections with individual fusing (max. 99 S9 devices per S9 Bus connection) -Paradox, Wireless expansion Module RTX3 -Adapter module to the NOX Bus assembled and wired in the paradox housing P221

Page 42 / 64

Components Overview July 2011

NOX Sensors
NOX THS, Temperature and Humidity Sensor

The NOX THS measures the air temperature and humidity in rooms. Its available for indoor or outdoor use. The measured values are transmitted through the NOX Bus to the control unit and for further processing. For both physical values an upper and a lower threshold can be set. The triggered warnings and alarms can be linked and evaluated as desired by software formulas. With the integrated relay a fan and air conditioner may be controled. The readings are stored for one year.On a PC trending for the last day, month or year is selectable. Specification (NOX THS internal)
Case Temper Monitoring Dimensions (L x W x H) Input Output Sensors Part. No. Plastic ABS, white (DASK Case) Integriert, through tamper contact 85 x 66 x 27 mm NOX Bus 1 Relay output potential-free (max. contact rating 30V/1A) precise combined sensor for temperature and relative humidity N150i

Specification (NOX THS external)


Sensorconnection Sensor Case Sensor Dimensions Sensor protection class (IEC 60529:2001) Scope of delivery Part. No. 3m Cable, 4 strands Duropol, black 30 x 20 x 15 mm IP 67 (only with Temperature sensor) - NOX Bus Module to connect a temperature/humidity sensor - external temperature and relative humidity sensor with 3m cable N150e

All other specifications are identical with part no. N150i.


Components Overview July 2011 Page 43 / 64

NOX THT, Wireless Temperature and Humidity Sensor


See also Wireless Components of NOX Picture Monitoring System (PMGS). The wireless NOX THT module measures temperature and relative humidity of the room air. The NOX RXM wireless receiver receives actually measured values and passes it on over the NOX BUS to the control unit.

Specification
Case Protection class (IEC 60529:2001) Dimensions (L x W x H) Temperature range Humidity range Wireless range Settings Power supply Battery life time Scope of delivery Part. No. Plastic white IP 40 58 x 51 x 13mm 25C: 0.3C 0 bis +40 C: 0.5C -20C bis +70C: 1.0C 10 bis 90% RH: 2% <10%, >90% RH: 4% Under open field conditions: 300m Inside of buildings:line of sight Adjustable transmission interval (8 levels) at change of temperature or humidity reading 2 x 1.5V Alkaline batteries AAAA 1 up to 2 years, dependent on the quantity of transmissions -NOX THT, wireless temperature and humidity sensor -2 pieces batteries Alkaline AAAA -Velcro Tape for easy mounting N159

Page 44 / 64

Components Overview July 2011

NOX FLD, Water Detector


In rooms with invaluable goods or equipment like museums, server and computer rooms, central heating room or in storage rooms serious property damage can happen in case of water ingress. NOX FLD detects the ingress of any conducting liquids in a reliable manner for many years.

Specification
Case Protection class (IEC 60529:2001) Dimensions (L x W x H) Length Sensor Cable Detectable Liquids Response time Sensor Output Connection to the Control Unit Part. No. PVC grey IP 68 (water and dust proof) 55 x 39 x 12 mm 3m All with a conductivity 150S 5ms Open Collector e.g. with a NOX Module, NOX IO1, NOX IO4 or similar M801

Components Overview July 2011

Page 45 / 64

Wireless Components of NOX Picture Monitoring System (PMGS)


Wireless receiver modules
NOX RXM, Wireless Receiver Module with NOX Bus
Receiver for the 868 MHz wireless signal from the NOX PMGS transmitters. The module has a NOX bus connection. This module is monitored (as all other NOX bus modules) by the CPU for sabotage. For monitoring purposes of the RF link, a reference transmitter (NOX TXM REF) can bei linked (configuration) with one or more receiver modules.

Specification
Case

Tamper Monitoring
Dimensions (L x W x H) Connection to the control unit Part. No.

Plastic ABS, white (DASK case) Integrated, through tamper contact 85 x 66 x 27mm (L=145mm with antenna) NOX Bus P110

Page 46 / 64

Components Overview July 2011

NOX RXR, Wireless Receiver Module with Relay


Receiver for the 868 MHz wireless signal from the NOX PMGS transmitters. The module is independent from the NOX control unit (no NOX Bus connection) and can be used to integrate the NOX Picture Monitoring System (PMG) into security systems of third party manufacterer.

Specification
Case

Tamper Monitoring
Dimensions (L x W x H) Output Part. No.

Plastic ABS, white (DASK case) Integrated, through tamper contact 85 x 66 x 27mm (L=145mm with antenna) 3 Relay output potential-free (max. contact rating 30V/1A) -Collective alarm pictures -Collective alarm external contacts -Collective alarm sabotage/battery malfunction P220

Components Overview July 2011

Page 47 / 64

NOX BPR, portable alerting receiver


The portable receiver with beltclip receives the 868MHz RF signals from the PMGS picture alarm detectors. In this compact case a red alarm LED, a green status LED, On/Off side switch and an alarm buzzer are integrated.

Specification
Case Dimensions (L x W x H) Weight Display Alarming Antenna Power Supply Part. No. Plastic ABS, white with beltclip 120 x 65 x 23mm 80g incl. batteries Status LED, green Alarm LED, red with LED and buzzer (integrated) Integrated 2 x 1.5V batteries AA P102

Page 48 / 64

Components Overview July 2011

Wireless transmitter modules


NOX TXM, wireless picture detector
The PMGS wireless picture detector indicates micromotion and touches of objects. The sensitivity is adjustable within 8 steps by a digital micro switch. The module is free of toxic materials in comarison to mercury switches. The detector module has the CE Label and it does not interfere with other wireless devices.

Specification
Case Dimensions (L x W x H) Weight Functional principle Alarming Antenna Wireless range Connections Power Supply Part. No. Plastic ABS, white 105 x 58 x 19mm 80g incl. batteries Vibration, 8 level of sensitivity Via RF and integrated buzzer Integrated Under open field conditions: 300m Inside of buildings: line of sight 1 x connection for an external contact 2 x 1.5V Alkaline batteries AAA P111

Components Overview July 2011

Page 49 / 64

NOX TXS, Wireless Picture Detector Mini


The NOX TXS module is a mini version of the TXM module. The functionality is identiacal with the NOX TXM module.

Specification
Case Dimensions (L x W x H) Weight Functions of the sensors Alarming Antenna Wireless range Connections Power Supply Part. No. Plastic PVC, grey; Epoxy cover dark green 58 x 51 x 13mm 45g incl. batteries Vibration, 8 level of sensitivity Via RF Integrated Under open field conditions: 300m Inside of buildings: line of sight 1 x connection for an external Contact 2 x 1.5V Alkaline batteries AAAA P112

Page 50 / 64

Components Overview July 2011

NOX TXK, Wireless Detector


With the NOX TXK module you can integrate any magnet or locking contact by RF into the NOX security system. The behavior is identical to any other contact in the NOX systen, but no wiring is necessary.

Specification
Case Dimensions (L x W x H) Weight Alarming Antenna Wireless range Connections Power Supply Part. No. Plastic ABS, white 105 x 58 x 19mm 80g incl. batteries Via RF and integrated buzzer (can be disabled) Integrated Under open field conditions: 300m Inside of buildings: line of sight 1 x Cable 70cm for an external contact 2 x 1.5V Alkaline batteries AAA P113

NOX TXT, Wireless Transmission Detector Mini


The NOX TXT Module is a mini version of the TXK Module. The functions are the same like at the NOX TXK Module.

Specification
Case Measurements (L x W x H) Weight Alarming Antenna Wireless range Connections Power Supply Part. No. Plastic PVC, green; epoxycover darkgreen 58 x 51 x 13mm 45g inkl. Batterien Via RF Integrated Uder open field conditions: 300m Inside of buildings: line of sight 1 x Cable 70cm for an external contact 2 x 1.5V Alkaline batteries AAAA P114

Components Overview July 2011

Page 51 / 64

NOX TXM REF, Radio Reference Transmitter


With the NOX TXM REF reference transmitter its possible to supervise the RF link between the transmitter and one or more receivers (NOX RXM).

Specification
Case Dimensions (L x W x H) Weight Alarming Antenne Wireless range Transmitter interval Power supply Part. No. Plastic ABS, white 105 x 58 x 19mm 80g Via RF, in malfunction of the reference signal Integrated Under open field conditons: 300m Inside of the building: line of sight Adjustable from 10..80s External power supply, 7..20VDC, 0.1W P999

Page 52 / 64

Components Overview July 2011

NOX THT, Wireless Temperature and Humidity Sensor


The wireless NOX THT module measures the temperature and relative humidity of the air in rooms. The readings are transmitted to the NOX RXM RF receiver which transfers it via NOX Bus to the NOX control unit.

Specification
Material Protection class (IEC 60529:2001) Dimensions (L x W x H) Temperature range Humidity range Wireless range Adjustable Options Power Supply Batterie lifetime Scope of delivery Part. No. Plastic, white IP 40 58 x 51 x 13mm 25C: 0.3C 0 bis +40 C: 0.5C -20C bis +70C: 1.0C 10 to 90% RH: 2% <10%, >90% RH: 4% Under open field conditions: 300m Inside of buildings: line of sight Adjustable Transmission interval (8 levels) for temperature and humidity values 2 x 1.5V Alkaline batteries AAAA 1 up to 2 Years, it depends on the number of transmissions -NOX THT, wireless temperature and humidity sensor -2 pieces alkaline batteries AAAA -Velcro tape for easy mounting N159

Components Overview July 2011

Page 53 / 64

Supplies / Accessories
Mounting Plate
Empty Plate for 8 DASK Cases

Specification
Material Dimensions (L x W x H) Mounting DASK Case Part. No. Aluminium 300 x 207 x 3 mm 16 x M3 threads to attach 8 DASK Cases 3 x M3 threads to attach a 30mm wide cable channel 4 x 4.5mm holes for the montage of the aluminium plate None T501

Mounting Plate with 8 DASK Cases and Cables

Specification
Mounting plate Dimensions (L x W x H) Mounting DASK Case Scope of delivery Part. No. Aluminium 300 x 207 x 3 mm 16 x M3 threads to attach 8 DASK Cases 3 x M3 threads to attach a 30mm wide cable channel 4 x 4.5mm holes to mount the plate 8 pieces preassemble on montage plate Preassembled and prewired on mounting plate: -8 x DASK Case -8 x Bus terminals -1 Cable channel T502

Page 54 / 64

Components Overview July 2011

Mounting Plate with 8 DASK Cases

Specification
Mounting plate Dimensions (L x W x H) Mounting DASK Case Scope of delivery Part. No. Aluminium 300 x 207 x 3 mm 16 x M3 threads to attach 8 DASK Cases 3 x M3 threads to attach a 30mm wide cable channel 4 x 4.5mm holes to mount the plate 8 pieces preassembled on the mounting plate Preassembled on mounting plate: -8 x DASK Case -1 Cable channel T503

Empty Plate for 4 DASK Cases


Specification
Material Dimensions (L x W x H) Mounting DASK Case Part. No. Aluminium 226 x 165 x 3 mm 8 x M3 threads to attach 4 DASK Cases 2 x M3 threads to attach a 30mm wide cable channel 4 x 4.5mm holes to mount the plate none T505

Components Overview July 2011

Page 55 / 64

Mounting Plate with 4 DASK Cases and Cables

Specification
Mounting plate Dimensions (L x W x H) Mounting DASK Case Scope of delivery Part. No. Aluminium 226 x 165 x 3 mm 8 x M3 thread to attach 4 DASK Cases 2 x M3 threads to attach a 30mm wide cable channel 4 x 4.5mm holes to mount the plate 4 pieces preassembled on the mounting plate Preassembled and pre-wired on montage plate: -4 x DASK Case -4 x Bus terminal -1 Cable channel T506

NOX TNA, Empty Mounting Plate


Specification
Material Dimensions (L x W x H) Mounting Part. No. Aluminium 245 x 182 x 3 mm 6 x 4mm holes to mount the plate in the old or new Control Unit housing T504

Page 56 / 64

Components Overview July 2011

DASK Case

Specification
Material Dimensions (L x W x H) Scope of delivery Part. No. Plastic ABS,white 85 x 66 x 27 mm Empty Case with 2 x M3x16 mm screws T552

PCBA Fixation for DASK Case

Specification
Material Scope of delivery Part. No. Plastic PVC, black 2 x fixation with screws M3x14 mm T551

Components Overview July 2011

Page 57 / 64

Batteries

Typ AAAA Specification


Part. No. T701 T702 T703 Type AA AAA AAAA

Typ AAA

Typ AA

Description Alkaline Batteries 1.5V (for NOX BPR) Set with 2 pieces Alkaline Batteries 1.5V (for NOX TXM / TXK) Set with 2 pieces Alkaline Batteries 1.5V (for NOX THT / TXS) Set with 2 pieces

Cables
Cables for the Control Unit: see under Control Units Spare Parts and Single Components P.8.

Cable NOX Bus, 4th Dask Plate

Specification
Cable Length NOX Bus Connections Part. No. 4 x PVC stranded wire, 1mm 3 x 20cm 4 x 4 poles, Type Phoenix T526

Page 58 / 64

Components Overview July 2011

Cable NOX Bus, 8th Dask Plate

Specification
Cable Length NOX Bus Connections Part. No. 4 x PVC stranded wire, 1mm 7 x 20cm 8 x 4 poles, Type Phoenix T527

NOX Bus Terminal

Specification
Type Number of connections Part. No. Phoenix Contact 4 N187

Components Overview July 2011

Page 59 / 64

USB Cable to CPU_V3 Motherboard


This cable makes it possible to update the operating system of the Toradex CPU module which is a component of the NOX CPU V3.

Specification
Typ Length Connection Scope of delivery Part. No. USB 1.1 Cable 0.6m USB Cable receptacle Type A female Cable assembled Without USB memory stick T530

Page 60 / 64

Components Overview July 2011

Spare Fuses for NOX Modules

This SMD fuse type is used within the following NOX modules: PSU, PS2, PS5, CPU V1, CPU V2, CPU V3 MIO, MIOe, RPT, S8P, IS9, IFT The rated current is dependent of the module and the specific application. General Specification
Manufacturer Type Outline shape Littlefuse SMD Fuse, 452 Series Nano2 (6.1 x 2.69 mm)

SMD Fuse Set 500mAT


Specification
Characteristic Fuses per set Rated Current Part No. slow blow 25 500mA N301

SMD Fuse Set 1AT


Specification
Characteristic Fuses per set Rated Current Part No. slow blow 25 1A N302

SMD Fuse Set 2AT


Specification
Characteristic Fuses per set Rated Current Part No. slow blow 25 2A N303

SMD Fuse Set 3AT


Specification
Characteristic Fuses per set Rated Current Part No. slow blow 25 3A N304

SMD Fuse Set 5AT


Specification
Characteristic Fuses per set Rated Current Part No. slow blow 25 5A N305

Components Overview July 2011

Page 61 / 64

NOX Software Components


NOX Config, PC Configuration Software for the NOX Security System
Configuration- and diagnostic software for start-up and maintenance of the NOX systems. Functionality: Update of the NOX System Software Management of customized configurations Detailed system informations Maintenance functionality Access to all logs Online user interface to the system Online Terminalwindow with realtime output
Part. No. S400

NOX PC Control Panel


PC Control Panel for the end user. Offers an easy but still complete operation of the security system on user level: Arm / disarm of areas Activate / deactivate of detectors View and acknowledge of alarms and warnings Shows all system logs Define of filter rules to view log entries Shows actual temperature / humidity sensor readings and history Change of temperature / humidity threshold values Shows information about picture monitoring detectors (incl. battery voltages) Management of user profiles and user codes Managment of time profiles
Licence Configuration Supported operating systems Part. No. None Runs directly without configuration Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit) S401

Page 62 / 64

Components Overview July 2011

NOX PC TPA Licence, PC Touch Panel Software Licence


The Touch Panel Software is designed to be used with a PC (with or without Touch Panel). The interaction with the system happens directly over the floor plans of the building. Supported functions: Arm / disarm of areas Activate / deactivate of detectors Alarm view and acknowledge Shows actual temperature / humidity sensor readings Shows all system logs Management of user codes Shows system state informations in the floor plans
Licence Configuration Supported operating systems Part. No. 1 End user licence for each control unit (e.g. the TPALoader software can be installed on any number of PC) The Module NOX TPA must be configured in the NOX Control Unit Microsoft Windows 2000, XP, Vista, 7 (32 and 64Bit) S100 This licence runs with: PCTPALoader.exe (Application TPA V1.00 to V1.99e which runs on TPA Rev.A and TPA Rev.B Hardware as well), not for new installations! PCTPA2Loader.exe (Application TPA V2.00 to actual Version which runs on TPA Rev.C Hardware as well)

Compatibility

NOX SIMS, Security Information Managment System


Professional security information management system with up to 128 NOX Control Units for up to 32 PC Workstations. It supports different Intrusion detection systems, fire detection systems and building automation systems. Base licence for 1 PC Workstation
Part. No. S405

Additional licence for 1 PC Workstation


Part. No. S407

NOX Logger
Stores all system logs as text file to a network drive (e.g. server). This results in nearly unlimited recording of all system actions. The history of all temperature and humidity sensors are stored as well.
Part. No. S402

NOX Time
Tracking of the labour time with direct connection to the NOX Control Unit. Staff members start and stop tracking by using control panel or card reader. Unlimited number of employees.
Components Overview July 2011 Page 63 / 64

Part. No.

S404

NOX iNOX
App to view and control of NOX security systems by iPhone (smartphone) or iPad (Tablet PC). The App allows to view and acknowledge alarms and warnings, arm and disarm of areas and the access the logs of the NOX system. This software application runs on all supported Apple platforms.
Licence Requirements Supported Apple platforms Distribution 1 Licence, bound to the user (Apple Licence) NOX Security System must be reachable from the Internet iPhone 3 iPhone 4 iPad iPad 2 through Apple iTunes Store iNOX

NOX iOS
Adds floor plans of the building to the iNOX App. Thus the NOX Security system can be controlled direct over the floor plans.
Licence Requirements Supported Apple Platforms Part. No. Bound to a NOX CPU NOX iNOX application (distributed throug the Apple iTunes Store). Optimized floor plans and adequate data points for the individual system configuration. Identically with iNOX S408