Provapor inox elance HI 912

! !

Service Information

Service Information

Service Information

Philips Domestic Appliances and Personal Care

Service Manual
SAP coding HI 912 PRODUCT INFORMATION Feataures : inox sole plate boiler capacity 1 litre length steam hose 1,9 metre length cord set 1,9 metre maximum steam output 60 gr/min : 220-240 Volt : 50-60 Hz : Boiler Pressure Iron : 1200 Watt : 2,5 bar : 800 Watt Voltage Frequency Power consumptium

Product meets the requirements regarding interference suppression on radio and television. - After the product has been repaired, it should function properly and has to meet the safety requirements as laid down ofcially established at this moment.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

Copyright reserved

Subject to modification

4322 277 00122 99/10


PCS 101 308

EXPLODED VIEW IRON

10

15 1 11 13

3 2

4 B B 5 B

6 A 12 13 C

7 14

Screws :

d 3.5 3.5 M4

x x x x

1 12 14 (3x) 124 (3x)

A B C

DAP0996

PCS 101 309

PARTS LIST IRON Pos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Description Inlay Micro switch Steam command lever Therm. dial Extention piece Handle Rattle Skirt Soleplate Lamp Ball swivel Back plate Thermostat Spring clamp Intermediate cable Service Nummer 9965 000 01887 9965 000 01888 9965 000 01680 9965 000 01681 9965 000 01682 9965 000 01683 4822 492 71445 9965 000 01684 9965 000 01685 9965 000 01686 9965 000 01687 9965 002 01689 9965 000 01690 4822 492 71001 9965 000 01691

TABLE UNIT
p

IRON
Cut out

Steamvalve

Cut out

Steamswitch

Thermostat

DISASSEMBLY ADVISE IRON BACK PLATE 12


remove SCREW A

HANDLE 6
cut

THERMOSTAT 13 ONLY
CONDUCTOR A at location P

ASSEMBLY REQUIREMENTS THERMOSTAT 2


Instead of metal conductor A, the new thermostat has a wire with AMP clamp. After xing screw D, connect the AMP clamp to tag Q. After assembling SKIRT 8 ALWAYS turn conductor B through 180 degrees.

INLAY 1

remove SCREW D

P Q
remove THERM. DIAL 4 remove SCREW B (4x)

B D

ADJUSTMENT AND CONTROLS


unlock HANDLE carefully remove LAMP 10 remove MICRO SWITCH 2

SKIRT 8
remove ELECTRICAL WIRES remove EXTENSION PIECE 5 remove SPRING CLAMP FROM STEAM HOSE remove SCREW C (3x) Bend back the contact points

Thermostat 13 Thermostat ( 13 ) supplied as a spare part or tted to the sole plate ( 9 ) has already been a djusted by the supplier and secured by glue. To avoid disfunction of the iron , NEVER readjust the thermostat.

NOTE : For opening you need a Torx screwdriver 362 TR T20 x 100.

PCS 101 310

EXPLODED VIEW STAND

D 22

24

23

21

26 31

27 25

33

32 28

30 27

34 29

DAP0999

PCS 101 311

PARTS LIST + DISASSEMBLY ADVICE STAND Pos 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DFU Description Stand rubber feet Rubber feet above screw Complete tray Safety valve Rubber ring in lling hole Cover Rubber feet boiler Boiler complete Locked insert Bottom housing Filter Switch Electro valve Cordset Italian plug Cordset Europe plug GBR, FRA, DEU, NLD, ESP, PRT, ITA Service Nummer 9965 000 01692 9965 000 01702 9965 000 01861 9965 000 01862 9965 000 01866 9965 000 01867 4822 462 71999 9965 000 01868 9965 000 01788 9965 000 01789 9965 000 01790 9965 000 01791 4822 218 11561 9965 000 01792 9965 000 01793 4222 001 92201 OPEN THE STAND

Below rubber feet remove SCREW D (1 x)

E E

ADJUSTMENT AND CONTROLS To avoid leakage of the sealings and damage to the components in and on the boiler, NEVER clean the boiler with vinegar, a descaling agent or other chemicals. The boiler doesnt contain serviceable parts. Never disassemble the boiler body and /or components on and in the boiler. ALWAYS REPLACE THE BOILER ( 28 ) WHEN:
removeSCREW E (3 x)

* *

the mechanical safety valve ( 24 ) has been activated. the boiler thermostat or hand - resettable safety thermostat are open, because the boiler has been subjected to too high temperatures. the electrovalve ( 33 ) fails or the sieve is soiled with scale.

remove LOCKED INSERT 29 NOTE: OPEN NOW THE STAND. DONT WORRY IF THE SNAPS AT THE SIDE WILL BE BROKEN. THEY ARE ONLY FOR THE ASSEMBLY. THE STAND REMAINS CLOSE WITHOUT THESE SNAPS.

After the product has been repaired, it should function properly and has to meet the safety requirements as laid down and ofcially established at this moment.