MEANS OF EGRESS OCCUPANT LOAD CALCULATIONS AND EXITS REQUIRED OCCUPANT LOAD ROOM AREA OCCUPANT LOAD ROOM

DESCRIPTION FACTOR NO. ASSEMBLY USE Concentrated use, without fixed seating Less concentrated use, without fixed seating Kitchens Library stack areas Library reading rooms Swimming Pools Swimming pool decks Exercise rooms with equipment Exercise rooms without equipment Stages Lighting and access catwalks, galleries, gridirons Casinos and similar gaming areas Skating rinks EDUCATIONAL USE Classrooms Shops, laboratories, vocational rooms DAY-CARE USE HEALTH CARE USE Inpatient treatment departments Sleeping departments Ambulatory health care DETENTION AND CORRECTIONAL USE RESIDENTIAL USE Hotel and dormitories Apartment buidings Board and care, large INDUSTRIAL USE

EXITS REQUIRED

0.65 net

1 1 1 1 1 1 1 1 1

1.40 net 9.30 9.30 4.60 net 4.60 (water surface) 2.80 4.60 1.40 1.40 net

1 0 0 0 0 0 0 1 1

1 1 1 1 1 1 1 1 1

1 1 1 1 1 1

9.30 net 1.00 4.60 1.90 net 4.60 net 3.30 net

0 1 0 1 0 0

1 1 1 1 1 1 1

1 1 1 1

22.30 11.10 9.30 11.10

0 0 0 0

1 1 1 1

1 1 1

18.60 18.60 18.60

0 0 0

1 1 1 1

General and high hazard industrial BUSINESS USE STORAGE USE In storage occupancies In mercantile occupancies In other than storage and mercantile occupancies MERCANTILE USE Sales area on street floor Sales area on two or more street floor Sales area on floor below street floor Sales area on floor above street floor Floor or portions of floors used only for offices

1 1

9.30 9.30

0 0

1 1

1 NA 1 27.90 0 1

46.50

1 1 1 1

2.80 3.70 2.80 5.60

0 0 0 0

1 1 1 1

9.30

Floors or portions of floors used only for storage, receiving, and shipping, and not open to general public 1 27.90 Mall buildings (per factor applicable to use of space) ROOM ROOM DESCRIPTION NO. Bench-type seating Fixed seating Waiting spaces Length or OCCUPANT LOAD FACTOR Number 1 0.46 l.m. 1 1.00 No. (see 12.1.7.2 and 13.1.7.2.)

OCCUPANT LOAD 2 1

EXITS REQUIRED 1 1

TOTAL OCCUPANT LOADS

13

ROOM NO.

MEANS OF EGRESS OCCUPANT LOAD CALCULATIONS AND EXITS REQUIRED OCCUPANT LOAD AREA OCCUPANT LOAD ROOM DESCRIPTION FACTOR

EXITS REQUIRED

BASEMENT FLOOR Storage-1 Storage-2 Maintenance Office Rentable Space-b1 Tank / Pump rooms Storage-3 Electl Rm-1 Rentable Space-b2 Mechanical Rm-1 Rentable Space-b3 Electl Rm-2 Storage-4 Parking / Garage

44 27.90 105 27.90 184 9.30 327 2.80 367 27.90 229 27.90 11 27.90 274 2.80 153 27.90 895 2.80 11 27.90 229 27.90 10,691 18.60 total OL for Basement floor=

2 4 20 117 13 8 0 98 5 320 0 8 575 1170

1 1 1 2 1 1 1 2 1 2 1 1 2 person

GROUND FLOOR Rentable shops Hypermarket Storage Extra shop

5,254 2.80 2,178 2.80 933 27.90 821 2.80 total OL for Ground floor=

1876 778 33 293 2981

2 2 1 2 person

FIRST FLOOR Rentable shops Food stalls Food Court Dining Restaurant

6,308 447 1,172 411

5.60 5.60 5.60 5.60

1126 80 209 73

2 2 2 2

2.8 9.3 1.4 1.4

Department Store-1 Department Store-2 Game arcade

2,197 5.60 1,090 5.60 991 5.60 total OL for First floor=

392 195 177 2253

2 2 2 person

2.8 2.8 9.3

ROOF FLOOR Landscape area Restaurants

8,149 ####### 884 1.40 total OL for First floor=

1 631 632

1 2 person

TOTAL OCCUPANT LOADS

7036

person

STAIR WIDTH COMPUTATION Occupant Load of 1st floor

x 7.6mm = total stair width required for 1st floor 2253 x 7.6 = 17122 mm (note: selected according to the upper floor that has the largest occupancy load) Occupant Load of Basement floor x 1170 x 7.6mm 7.6 = = = = = total stair width required for basement floor 8893 mm 26015 5 5203 mm No No

Total Stair Width Required No. of Stairs available Required width of each stairs

GROUND FLOOR EXIT DOOR WIDTH COMPUTATION Occupant Load of Ground floor x 2981 x

5mm 5

= =

total exit door width required 14903 mm

Note:

Minimum distance between stairs is 1/3 of diagonal distance of building Suggested minimum distance between exit doors is 1/3 of diagonal distance of bldg