ETA

Product Catalogue

General

Shaft Seal

The ETA low-pressure centrifugal pump built by KSB considers fully the recommendations of DIN 24255 with regard to
main dimensions and rated capacities.

Uncooled soft-packed stuffing box up to 110C, or cooled softpacked stuffing box over 110C, up to 160C. Uncooled
mechanical seals up to 140C max. may be fitted.

By the adaption to the standardised water pump and utilising


the meccano system, the ETA series provides economic
advantages for plant designers, plant manufacturers and
users.

Drive

Fields of Application
General water supply for municipalities, industry and agriculture; for irrigation and drainage or pumping of sea water,
brines, Iyes and condensate; circulation of hot water, cooling
water and oil; for blending and loading duties, etc.

Design
Horizontal single-stage, single-flow centrifugal pump with
volute casing flanged onto the bearing pedestal.
Axial suction nozzle and radial discharge nozzle vertically
upwards, overhung radial flow impeller, shaft protecting
sleeves of 316 stainless steel.

Direct drive by an electric motor, an internal combustion


engine or turbine, via a flexible coupling.
In special cases drive is also possible via a gear box, a
hydraulic gear coupling, or belt drive (overhung or via a jackshaft). If a spacer type coupling is used, the complete pump
rotor can be withdrawn towards the motor end, without having
to remove the motor or to disconnect the piping from the
pump casing.

Bearings
Axial and radial location by two oil lubricated deep groove ball
bearings in the bearing pedestal. Grease lubricated bearings
are available as an optional extra.

ETA

Fig 2 Selection Chart (n = 1450 r.p.m.)

Fig 1 Selection Chart (n = 2900 r.p.m.)

ETA
(90-1.3)
920.2
920.1
458
10E/11E
902.2

(90-1.1)
902.1

102
230

1M 451

400.1

400.3

332
507

913

Pump size Shaft unit


40-200

360
901

940.1

STANDARD DESIGN
HOT WATER DESIGN

25

920.3

550
930

940.2

6B 457
(90-1.2)

461
524

7E/7A
412.2

165
8B

902.3

452.1 321 210

412.1

Impeller with back vanes for hydraulic balancing


230
102

Pump size

Shaft unit

40-250

25

50-200

25

50-250

25

65-200

25

(90-1.1)
1M
451

(90-1.3)
902.1

920.1
400.1

458

920.2
902.2

10E/11E

332
507

360

400.3
913

901

940.1

STANDARD DESIGN
HOT WATER DESIGN

930
920.3

7E/7A
461
940.2
165
902.3
457
550
6B
524
412.2
8B
412.1
(90-1.3)

321
210

452.1

Impeller with balance holes for hydraulic balancing

902.1
920.1

731.1

Pump size

Shaft unit

32-160

20

32-200

20

400.1

10E
11E
451

902.1
920.1

461
454

458

330

901
210

940.1

1M
102
230

32-250

25

40-125

20

502.2
502.1

40-160

20

50-160

20

65-125

20

360

65-160

25

321

80-160

25

100-160

35

400.2

920.3

183

930
550.1
6B
731.2

940.2
(940.3)

457
8B

452
524

507

ETA
102

Pump size

Shaft unit

40-315

35

50-315

35

65-315

35

913
210

400.2
321

901

STANDARD DESIGN
HOT WATER DESIGN

930 6B

(90-1.2)

920.3

524

940.2

412.2
165
461
7E 7A

412.1
8B

452.1
902.3

940.1
360

Impeller unbalanced
102

(90-1.1)
230 1M 458

451

332
321
901
210
902.1 (90-1.3) 920.2
400.1
902.2
920.1
507
913
400.2
360
940.1
10E/11E

1) Feet are integrally cast to the


volute casing of sizes 80-400,
100-400,125-315,125-400,
150-200, 150-250, 150-315
and 150-400.

Pump size Shaft unit


80-315

35

80-400

45

100-400

45

125-315

45

150-315

45

STANDARD DESIGN
HOT WATER DESIGN

920.3

940.2 6B
940.3
(90-1.2)
930

400.2
461

7E 7A

412.2

165
8B

902.3

Subject to technical modification without prior notice

Volute casing 1)
Cooling cover
Shaft
Impeller
Deep groove ball bearing
Bearing pedestal
Bearing cover
Flat gasket
O-ring
Stuffing box housing
Stuffing box gland
Neck ring
Split lantern ring
Stuffing box packing
Thrower
Shaft protecting sleeve
Washer
Hex bolt
Stud
Vent plug
Hexagonal nut
Spring washer
Key
Pressure gauge
Draining
Cooling liquid outlet
Cooling liquid inlet
Leakage drain
Sealing liquid inlet
Flushing liquid inlet

902.1
(90-1.1)
920.2
332
(90-1.3)
451
230 1M 458
400.1
920.1
902.2
507
10E/11E

452.1

412.1

Impeller with back vanes for hydraulic balancing


Pump size

Shaft unit

65-250

35

80-200

35

80-250

35

100-200

35

100-250

35

100-315

35

125-200

35

125-250

35

125-400

45

150-200

35

150-250

35

150-400

45

920.1
451
400.1
(90-1.1) (90-1.3)
1M
10E/11E
902.1

332

920.2
524

902.2

210
913

507

940.1

901
321

360

05.02.2007

102
165
210
230
321
332
360
400.1/.2
412.1/.2
451
452
457
458
461
507
524
550
901
902
913
920.3
930
940
1M
6B
7A
7E
8B
10 E
11 E

Designation

458
230
940.1
102

STANDARD DESIGN
HOT WATER DESIGN

461
165
412.1 902.3
6B
550
(90-1.2)
920.3
930
457 412.2
7E 7A
8B

452

400.2

Impeller with balance holes for hydraulic balancing

KSB Pumps and Valves (Pty) Ltd.


P.O. Box 2938, Primrose 1416, Cor. North Reef & Activia Roads, Activia Park, Germiston.
Tel: (011) 876-5600 Fax: (011) 822-2013 www.ksbpumps.co.za

Gartone Press: Tel: (011) 440-6126